https://arxiv.org/api/FGTy3h/EUzJHfO2jfFgV+mO67n0 2026-04-09T09:45:05Z 8808 165 15 http://arxiv.org/abs/2505.11155v2 Controlling spatial correlation in k-space interpolation networks for MRI reconstruction: denoising versus apparent blurring 2026-02-16T16:18:16Z Purpose: Interpretability is essential for the clinical adoption of state-of-the-art machine learning (ML) methods in magnetic resonance imaging (MRI). Conventional evaluation of ML reconstructions relies heavily on aggregate image metrics that require fully sampled references. These metrics, inherited from classical image processing and natural image ML, often overlook the critical challenge of noise amplification specific to medical image reconstruction. This study aims to analyze the influence of nonlinear activations on spatial noise variance distribution of k-space interpolation networks (RAKI) and to provide a framework for incorporating variance maps during network training. Methods: We present an analytical framework that decomposes pixel-level noise variance into components reflecting linear and nonlinear characteristics of RAKI. By applying automatic differentiation on the image-space equivalent of the network, variance maps are computed during each training iteration, enabling runtime quality assessment beyond data consistency. We introduce apparent blurring, quantifying nonlinear signal mixing without dependence on reference images. By incorporating variance maps into the traning loss as regularizers, our self-informed RAKI architecture (G-factor-informed RAKI, GIF-RAKI) can directly integrate updated noise characteristics during runtime. Results: Experimental results demonstrate that variance components quantitatively explain network behavior. GIF-RAKI outperforms conventional RAKI variants in image fidelity and noise suppression. Conclusion: Our methodology advances practical and theoretical aspects of ML-based MRI reconstruction by reinstating reconstruction noise characterization as a cornerstone for performance evaluation, eliminating the need for fully sampled references. GIF-RAKI also enables optimization of the trade-off between denoising and apparent blurring. 2025-05-16T11:57:31Z Istvan Homolya Jannik Stebani Felix Breuer Grit Hein Matthias Gamer Florian Knoll Martin Blaimer http://arxiv.org/abs/2602.14639v1 Biomechanics of the abdominal wall before and after ventral hernia repair using dynamic MRI 2026-02-16T10:55:06Z Purpose: This study aims to investigate the use of dynamic MRI to assess abdominal wall biomechanics before and after hernia surgery, considering that such evaluations can enhance our understanding of physiopathology and contribute to reducing recurrence rates. Methods: Patients were assessed using dynamic MRI in axial and sagittal planes while performing exercises (breathing, coughing, Valsalva) before and after their abdominal hernia surgery with mesh placement. Rectus and lateral muscles, linea alba, viscera area, defect dimensions and hernia sac were contoured with semi-automatic process to quantify the abdominal wall biomechanical temporal modifications. Results: This study enrolled 11 patients. During coughing, the axial area of the hernia sac increased by 128.4 $\pm$ 199.2%. The sac increased similarly in axial and sagittal planes during Valsalva. Post-surgical evaluations showed a 26% reduction in inter-recti distance and a lengthening of all muscles (p $\le$ 0.05). The post-operative rectus abdominis thickness change was negatively correlated with defect width during breathing (p $\le$ 0.05). The largest change in linea alba displacement was observed in the surgical site (p = 0.07). Post-operatively, lateral muscles had a larger inward displacement during Valsalva (p $\le$ 0.05). Rectus abdominis had a larger outward displacement during breathing (p = 0.09), reduced with the mesh size (p $\le$ 0.05). A large inter-individual variability was observed. Conclusion: Using a semi-automatic methodology, an in-depth analysis of the biomechanics of the abdominal wall was conducted, highlighting the importance of a patient-specific assessment. A broader study and consideration of recurrence would subsequently complete this methodological work. 2026-02-16T10:55:06Z Hernia, 2025, 29 (1), pp.185 Victoria Joppin LBA UMR T24, CRMBM David Bendahan CRMBM Ahmed Ali El Ahmadi LBA UMR T24 Catherine Masson LBA UMR T24 Thierry Bege LBA UMR T24 http://arxiv.org/abs/2602.14394v1 Increasing ultrasound field-of-view with reduced element count arrays containing large elements 2026-02-16T01:56:09Z Several applications of medical ultrasound can benefit from a larger imaging field of view (FOV). This study is aimed at increasing the FOV of linear array probes by increasing the element size rather than the element count. To investigate larger FOV, this study used coupled elements to imitate a larger element size. The effects of coupling on array beam patterns are examined with Fourier transforms of elements. The effects of coupling on resolution, contrast, and speckle signal-to-noise ratio are examined through phantom images and in-vivo images of a rabbit tumor reconstructed with plane-wave compounding. Furthermore, a positioning system was used to acquire data from a virtual large aperture with 120 mm FOV and 128 elements, collected in sections with a single probe. This study also investigates the Null Subtraction Imaging (NSI), Sign Coherence Factor (SCF), and Minimum Variance (MV) beamformers for regaining resolution lost by an increased F-number with large elements. The MV beamformer, while the most computationally expensive, was best for improving resolution without increasing speckle variance, decreasing Full-Width at Half-Max (FWHM) estimates of wire targets from 0.78 mm with DAS on a 2.5 wavelength element size to 0.54 mm with MV on a 5 wavelength element size. 2026-02-16T01:56:09Z Mick Gardner Rita J. Miller Michael L. Oelze http://arxiv.org/abs/2602.14315v1 Complex Wavelet-Based Sinogram Segmentation for Metal Artifact Reduction in Cone-Beam CT 2026-02-15T21:33:25Z Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These artifacts degrade image quality and limit the reliability of subsequent medical analysis. We propose a projection-domain metal artifact reduction method based on analytical metal segmentation in the three-dimensional sinogram using the three-dimensional Dual-Tree Complex Wavelet Transform, where directional wavelet coefficients are exploited to extract the wavefront set and singular support of metal structures. The resulting segmentation enables projection-domain inpainting and artifact-reduced reconstruction by combining metal-free and metal-only reconstructions. The proposed approach is evaluated on both simulated and clinical cone-beam computed tomography data and consistently reduces metal artifacts compared to conventional image-domain hard-thresholding methods. The results demonstrate improved visual quality and robustness in clinically realistic scenarios, highlighting the potential of analytically grounded, non-learned projection-domain segmentation for metal artifact reduction. 2026-02-15T21:33:25Z Siiri Rautio Alexander Meaney Salla-Maaria Latva-Äijö Harshit Agrawal Mikael Brix Dinidu Jayakody Samuli Siltanen http://arxiv.org/abs/2510.10786v2 Electron-hole liquid in biological tissues under ultra high dose rate ionizing radiation 2026-02-15T20:23:33Z We develop a quantitative model of ionization processes in biological tissues under Ultra High Dose Rate (UHDR) radiation. The underlying conjecture is that of electron-hole liquid (EHL) forming in water based substances of biological tissues. Unlike the earlier known EHL in semiconductor crystals, the charge carriers here are low mobile due to strong interactions with the background (solvated electrons, etc.); hence, EHL resembling ionic melts. Similar to all ionic systems, the Coulomb coupling makes that EHL energetically favorable that leads to recombination barriers suppressing subsequent structural transformations. In particular, generation of secondary reactive species in such EHL becomes limited translating into reduction of biological damages and tissue sparing effect. We show how these processes are sensitive to the tissue quality and frequency dispersion of the dielectric permittivity. Equations for dose and dose rate defining the sparing thresholds are derived. 2025-10-12T20:04:54Z 6 pages, 5 figures Diana Shvydka Victor Karpov 10.1103/3ly7-yswy http://arxiv.org/abs/2602.23386v1 Controlled release from polyurethane films: drug release mechanisms 2026-02-15T20:21:03Z In this study, polyurethane-films loaded diclofenac were used to analyze the drug release kinetics and mechanisms. For this purpose, the experimental procedures were developed under static and dynamic conditions with different initial drug loads of 10, 20, and 30%. In the dynamic condition, to better simulate the biological flow, drug release measurements were investigated at flow rates of 7.5 and 23.5 ml/s. These values indicate the flow rate of the internal carotid artery (ICA) for a normal state of a body and for a person during the exercise, respectively. The experimental data were analyzed and adjusted by Higuchi, Korsmeyer-Peppas, First-order, zero-order, and Peppas-Sahlin models in order to understand the mechanisms contributed. Finally, Drug release mechanisms were specified by investigating the model correlation coefficients. Experimental results showed that increasing the flow rate and initial drug loads enhance drug liberation. In addition, the rate of release is more influenced by the drug dosage in the static state. The analysis revealed that diffusion, burst, and osmotic pressure are the principal mechanisms contributed. Moreover, Fickian type was the dominant mechanism at all duration of release. However, it was discovered using Peppas-Sahlin model that the contribution of the diffusion mechanism decreases with increasing flow rate and initial dosage. Furthermore, the tests at different drug dosages showed that the number of stages in medication release profile is independent of the flow rate and the medicine percentage. One can conclude that the drug release kinetic in static state is more influenced by drug dosage compare to dynamic state. 2026-02-15T20:21:03Z Journal of Applied Polymer Science, 138 (2021) 50083 N. Abbasnezhad N. Zirak M. Shirinbayan S. Kouidri E. Salahinejad A. Tcharkhtchi F. Bakir 10.1002/app.50083 http://arxiv.org/abs/2602.14264v1 Magnetocardiography measurements using an optically pumped magnetometer under ambient conditions 2026-02-15T18:29:54Z In this work, we report the development of a rubidium-based single-beam scalar optically pumped magnetometer (OPM) and demonstrate its application in measuring human cardiac magnetic fields in an unshielded environment. The developed magnetometers exhibit a noise floor below 15 pT/sqrt(Hz) in the frequency range of 1 to 35 Hz, with a measurement bandwidth of 100 Hz. When operated in a gradiometric configuration, the noise floor is further reduced to below 3 pT/sqrt(Hz) over the same frequency range. Magnetocardiography (MCG) signals were recorded at five different locations across the thorax. A clear polarity reversal of the QRS complex was observed across these measurement positions, confirming the spatial sensitivity of the system. The proposed system shows strong potential for clinical diagnostics, offering valuable physiological information through non-contact MCG measurements 2026-02-15T18:29:54Z Kushal Patel Kesavaraja C Pranab Dutta Korak Biswas http://arxiv.org/abs/2602.06212v2 Causal machine learning reveals age-dependent radiation dose effects on mandibular osteoradionecrosis 2026-02-15T04:46:31Z Distinguishing causal relationships from statistical correlations remains a fundamental challenge in clinical research, limiting the translation of observational findings into interventional treatment guidelines. Here we apply causal machine learning to establish causal effects of radiation dose parameters on mandibular osteoradionecrosis (ORN) in 931 head and neck cancer patients treated with volumetric-modulated arc therapy. Using generalized random forests, we demonstrate that all examined dosimetric factors exhibit significant positive causal effects on ORN development (average treatment effects: 0.092-0.141). Integration with explainable machine learning reveals substantial treatment effect heterogeneity, with patients aged 50-60 years showing the strongest causal dose-response relationships (conditional average treatment effects up to 0.229), while patients over 70 years demonstrate minimal effects. These results suggest that age-stratified treatment optimization and personalized treatment planning for the dosimetric factors could reduce ORN risk. Our findings demonstrate that causal inference methods can transform clinical retrospective radiotherapy data into personalized treatment recommendations, providing a methodological framework applicable to toxicity prediction across oncology and other clinical domains where treatment decisions depend on complex dose-response relationships. 2026-02-05T21:42:09Z Jingyuan Chen Yunze Yang Olivia M. Muller Lei Zeng Zhengliang Liu Tianming Liu Robert L Foote Daniel J Ma Samir H Patel Zhong Liu Wei Liu http://arxiv.org/abs/2506.04748v2 Synchro-Thermography: Monitoring ~10 mK Facial Temperature Changes with Heartbeat Referencing for Physiological Sensing 2026-02-14T01:59:25Z Infrared thermography has gained interest as a tool for non-contact measurement of blood circulation and skin blood flow due to cardiac activity. Partiularly, blood vessels on the surface, such as on the back of the hand, are suited for visualization. However, standardized methodologies have not yet been established for areas such as the face and neck, where many blood vessels are lie deeper beneath the surface, and external stimulation for measurement could be harmful. Here we propose Synchro-Thermography for stable monitoring of facial temperature changes associated with heart rate variability. We conducted experiments with eight subjects and measured minute temperature changes with an amplitude of about \SI{10}{mK} on the forehead and chin. The proposed method improves the temperature resolution by a factor of 2 or more, and can stably measure skin temperature changes caused by blood flow. This skin temperature change could be applied to physiological sensing such as blood flow changes due to injury or disease, or as an indicator of stress. 2025-06-05T08:31:41Z This paper has been submitted to the 2025 SICE Festival with Annual Conference (SICE FES 2025) 2025 SICE Festival with Annual Conference (SICE FES) (2025) 1249-1254 Nanami Kotani Kuniharu Sakurada Jiayi Xu Masahiko Inami Yasuaki Monnai 10.23919/SICEFES67750.2025.11236693 http://arxiv.org/abs/2602.13535v1 Biocompatibility of Additively Manufactured Fe-AZ31 Biodegradable Composites for Craniofacial Implant Applications 2026-02-14T00:22:03Z Metallic plating systems composed of titanium and its alloys remain the standard treatment for craniofacial bony fixation but may require secondary removal due to infection, implant migration, or discomfort. Thus, biodegradable metallic implants may eliminate complications and secondary procedures while maintaining structural integrity. Our previous work demonstrated the fabrication of immiscible Fe-AZ31 composites via additive manufacturing with improved degradation kinetics over pure Iron. This study aimed to evaluate the in vitro and in vivo biocompatibility of Fe-AZ31 composites for potential craniofacial fixation applications. Pure iron (Fe), Mg alloy (AZ31) and Fe-AZ31 samples were fabricated for extract-based cytotoxicity testing using HFF-1 fibroblasts, L929 fibroblasts and hFOB osteoblasts. Metal extracts were prepared at a 3 cm^2/mL surface-to-volume ratio in complete media at 37C and cell viability was measured by live/dead assay after 24 and 72h exposure. For in vivo evaluation, Fe-AZ31, Fe, and Ti plates were implanted subcutaneously in wild type mice for 6 weeks, 3 and 6 months. Implant degradation, histologic response, hematology, and serum biochemistry were assessed. Fe-AZ31 extracts demonstrated >70% cell viability across all cell types at both timepoints with normal cell morphology and adhesion, whereas AZ31 extracts caused marked cytotoxicity associated with pronounced alkalization (pH 10). In vivo, Fe-AZ31 implants exhibited gradual surface corrosion accompanied by mild, transient inflammation and minimal capsule formation over time. No systemic toxicity was observed. Hematology and serum biochemistry remained within physiological limits. Additively manufactured Fe-AZ31 composites demonstrate acceptable biocompatibility and favorable tissue responses, supporting their development as resorbable metallic fixation devices for craniofacial reconstruction. 2026-02-14T00:22:03Z Xue Dong Samuel Medina Sai Pratyush Akula Abby Chopoorian Fuchsman Matthew W. Liao Sophia Salingaros Atieh Moridi Jason A. Spector http://arxiv.org/abs/2311.17824v2 Depth-multiplexing spectral domain OCT for full eye length imaging with a single modulation unit 2026-02-13T22:29:28Z Clinical measurement of a patient's axial eye length is emerging as a crucial approach to track progression and monitor management of myopia. However, the preferred method for such measurements is swept-source OCT, whose cost prohibits broad use, especially in lower-income communities. Spectral domain (SD) OCT is a more affordable option, but it has limited imaging depth range, so is not suitable for full eye length measurement. Depth-multiplexing (DM) techniques for SD-OCT provide a workaround by capturing images at multiple depths within the eye. However, these methods typically require multiple light modulation units or detectors for simultaneous imaging across depths, adding complexity and cost. In response, we propose a novel DM-SD-OCT approach that utilizes a single light modulation unit for depth encoding. We capture images at multiple depths within the eye simultaneously with a single line scan camera, then computationally demix the contributions from different depths. Here, we demonstrate acquisition and demixing of signals from three distinct depths within the eye and validate experimentally in human subjects. Our method thus offers a cost-effective solution for comprehensive eye length measurement in clinical myopia research. 2023-11-29T17:24:26Z Guanghan Meng Xue Dong Andrew Zhang Fabio Feroldi Austin Roorda Laura Waller http://arxiv.org/abs/2409.13477v5 A Plug-and-Play Method for Guided Multi-contrast MRI Reconstruction based on Content/Style Modeling 2026-02-13T14:08:09Z Since multiple MRI contrasts of the same anatomy contain redundant information, one contrast can guide the reconstruction of an undersampled subsequent contrast. To this end, several end-to-end learning-based guided reconstruction methods have been proposed. However, a key challenge is the requirement of large paired training datasets comprising raw data and aligned reference images. We propose a modular two-stage approach that does not require any k-space training data, relying solely on image-domain datasets, a large part of which can be unpaired. Additionally, our approach provides an explanatory framework for the multi-contrast problem based on the shared and non-shared generative factors underlying two given contrasts. A content/style model of two-contrast image data is learned from a largely unpaired image-domain dataset and is subsequently applied as a plug-and-play operator in iterative reconstruction. The disentanglement of content and style allows explicit representation of contrast-independent and contrast-specific factors. Consequently, incorporating prior information into the reconstruction reduces to a simple replacement of the aliased content of the reconstruction iterate with high-quality content derived from the reference scan. Combining this component with a data consistency step and introducing a general corrective process for the content yields an iterative scheme. We name this novel approach PnP-CoSMo. Various aspects like interpretability and convergence are explored via simulations. Furthermore, its practicality is demonstrated on the public NYU fastMRI DICOM dataset, showing improved generalizability compared to end-to-end methods, and on two in-house multi-coil raw datasets, offering up to 32.6\% more acceleration over learning-based non-guided reconstruction for a given SSIM. 2024-09-20T13:08:51Z Chinmay Rao Matthias van Osch Nicola Pezzotti Jeroen de Bresser Mark van Buchem Laurens Beljaards Jakob Meineke Elwin de Weerdt Huangling Lu Mariya Doneva Marius Staring http://arxiv.org/abs/2602.12933v1 Deep-Learning Atlas Registration for Melanoma Brain Metastases: Preserving Pathology While Enabling Cohort-Level Analyses 2026-02-13T13:43:57Z Melanoma brain metastases (MBM) are common and spatially heterogeneous lesions, complicating cohort-level analyses due to anatomical variability and differing MRI protocols. We propose a fully differentiable, deep-learning-based deformable registration framework that aligns individual pathological brains to a common atlas while preserving metastatic tissue without requiring lesion masks or preprocessing. Missing anatomical correspondences caused by metastases are handled through a forward-model similarity metric based on distance-transformed anatomical labels, combined with a volume-preserving regularization term to ensure deformation plausibility. Registration performance was evaluated using Dice coefficient (DSC), Hausdorff distance (HD), average symmetric surface distance (ASSD), and Jacobian-based measures. The method was applied to 209 MBM patients from three centres, enabling standardized mapping of metastases to anatomical, arterial, and perfusion atlases. The framework achieved high registration accuracy across datasets (DSC 0.89-0.92, HD 6.79-7.60 mm, ASSD 0.63-0.77 mm) while preserving metastatic volumes. Spatial analysis demonstrated significant over-representation of MBM in the cerebral cortex and putamen, under-representation in white matter, and consistent localization near the gray-white matter junction. No arterial territory showed increased metastasis frequency after volume correction. This approach enables robust atlas registration of pathological brain MRI without lesion masks and supports reproducible multi-centre analyses. Applied to MBM, it confirms and refines known spatial predilections, particularly preferential seeding near the gray-white matter junction and cortical regions. The publicly available implementation facilitates reproducible research and extension to other brain tumours and neurological pathologies. 2026-02-13T13:43:57Z Nanna E. Wielenberg Ilinca Popp Oliver Blanck Lucas Zander Jan C. Peeken Stephanie E. Combs Anca-Ligia Grosu Dimos Baltas Tobias Fechter http://arxiv.org/abs/2602.12917v1 Ultrasound-Guided Real-Time Spinal Motion Visualization for Spinal Instability Assessment 2026-02-13T13:23:29Z Purpose: Spinal instability is a widespread condition that causes pain, fatigue, and restricted mobility, profoundly affecting patients' quality of life. In clinical practice, the gold standard for diagnosis is dynamic X-ray imaging. However, X-ray provides only 2D motion information, while 3D modalities such as computed tomography (CT) or cone beam computed tomography (CBCT) cannot efficiently capture motion. Therefore, there is a need for a system capable of visualizing real-time 3D spinal motion while minimizing radiation exposure. Methods: We propose ultrasound as an auxiliary modality for 3D spine visualization. Due to acoustic limitations, ultrasound captures only the superficial spinal surface. Therefore, the partially compounded ultrasound volume is registered to preoperative 3D imaging. In this study, CBCT provides the neutral spine configuration, while robotic ultrasound acquisition is performed at maximal spinal bending. A kinematic model is applied to the CBCT-derived spine model for coarse registration, followed by ICP for fine registration, with kinematic parameters optimized based on the registration results. Real-time ultrasound motion tracking is then used to estimate continuous 3D spinal motion by interpolating between the neutral and maximally bent states. Results: The pipeline was evaluated on a bendable 3D-printed lumbar spine phantom. The registration error was $1.941 \pm 0.199$ mm and the interpolated spinal motion error was $2.01 \pm 0.309$ mm (median). Conclusion: The proposed robotic ultrasound framework enables radiation-reduced, real-time 3D visualization of spinal motion, offering a promising 3D alternative to conventional dynamic X-ray imaging for assessing spinal instability. 2026-02-13T13:23:29Z Feng Li Yuan Bi Tianyu Song Zhongliang Jiang Nassir Navab http://arxiv.org/abs/2602.12805v1 A Wavefield Correlation Approach to Improve Sound Speed Estimation in Ultrasound Autofocusing 2026-02-13T10:40:20Z Aberration often degrades ultrasound image quality when beamforming does not account for wavefront distortions. In the past decade, local sound speed estimators have been developed for distributed aberration correction throughout a medium. Recently, iterative sound speed optimization approaches have achieved more accurate estimates than earlier approaches, but these newer methods still struggle with decreased accuracy for media with reverberation clutter and large sound speed changes. To address these challenges, we propose using a wavefield correlation (WFC) beamforming approach when performing sound speed optimization. WFC correlates simulated forward-propagated transmit wavefields and backwards-propagated receive wavefields in order to form images. This process more accurately models wave propagation in heterogeneous media and can decrease diffuse clutter due to its spatiotemporal matched filtering effect. This beamformer is implemented using auto-differentiation software to then perform gradient descent optimization, using a total-variation regularized common midpoint phase focus metric loss, on the local sound speed map used during beamforming. This approach is compared to using delay and sum (DAS) with straight-ray time delay calculations in the same sound speed optimization approach on a variety of simulated, phantom, and in vivo data with large sound speed changes and clutter. Results show that using WFC decreases sound speed estimation error, and using the estimates for aberration correction improves image resolution and contrast. These promising results have potential to improve pulse-echo imaging for challenging clinical scenarios. 2026-02-13T10:40:20Z Louise Zhuang Samuel Beuret Ben Frey Saachi Munot Jeremy J. Dahl