https://arxiv.org/api/FGTy3h/EUzJHfO2jfFgV+mO67n02026-06-21T15:04:22Z898516515http://arxiv.org/abs/2605.00239v1Resolution-Noise Characteristics of Common FDK Filter Kernels: A Practical Reference for Preclinical Cone-Beam Micro-CT2026-04-30T21:17:33ZThe ramp filter kernel and cutoff frequency are fundamental parameters of the Feldkamp-Davis-Kress (FDK) algorithm that determine the resolution and noise characteristics of the reconstructed image. Despite their importance, systematic evaluations of their combined effect on task-based image quality in preclinical micro-CT are scarce, and many studies do not report the filter configuration used. We reconstruct identical data from a GE eXplore CT 120 scanner using four filter kernels (ramp, Shepp-Logan, cosine, Hamming) at four cutoff frequencies (1.0, 0.8, 0.6, and $0.379\times$ Nyquist, matched to the detector-to-voxel size ratio) and evaluate each of the sixteen configurations using the modulation transfer function (MTF), noise power spectrum (NPS), and non-prewhitening detectability index (NPW $d'$). Qualitative assessment is performed on a mouse lung specimen. Across the sixteen configurations, $\mathrm{MTF}_{10}$ ranges from 0.93 to 2.35 lp/mm, integrated NPS from 75,670 to 13,259 $\mathrm{HU}^2$, and the Rose criterion crossing diameter from 2.86 to 0.93 mm at $ΔC = 500$ HU and from 7.74 to 3.62 mm at 100 HU. This note presents the data as a concise visual and quantitative reference for groups selecting FDK filter parameters for preclinical cone-beam CT.2026-04-30T21:17:33ZFalk L WiegmannNancy L Fordhttp://arxiv.org/abs/2605.00144v1Model-aided quantification of patient-specific benefit in mitigating radiation induced lymphopenia by particle therapy of cancer2026-04-30T19:00:55ZTreatment-related lymphopenia is a frequent and clinically significant consequence of cancer therapy that can compromise immune-mediated tumor control and worsen patient outcomes. Despite its importance, no mechanistic framework exists to accurately predict the severity of lymphopenia from patient-specific data. Here, we present a biokinetic model that quantitatively describes lymphocyte depletion and recovery during and after radiotherapy, integrating radiation dose-volume distributions, blood circulation dynamics, and distinct kinetics of fast- and slow-recovering lymphocyte populations. The model was calibrated and validated using 56 independent clinical datasets encompassing various tumor sites and treatment modalities. It reproduces observed lymphocyte counts and enables prediction of individual severity of lymphopenia from baseline or early-treatment counts. Applying this framework, we demonstrate that particle therapy reduces lymphocyte depletion by ~30% compared with photon therapy, providing a quantitative explanation for its observed immune-sparing benefit. By linking radiation physics, immune kinetics, and clinical outcomes, our model establishes a mechanistically grounded predictive approach for anticipating systemic immune toxicity. Beyond radiotherapy, this framework offers a generalizable strategy for integrating early biological markers into treatment optimization, advancing personalized and immune-preserving cancer therapy.2026-04-30T19:00:55Z27 pages, 4 figuresVladislav SandulMarco DuranteThomas Friedrichhttp://arxiv.org/abs/2604.27658v1Mechanistic driven TCP and NTCP modeling for particle therapy accounting for a broad range of physical irradiation parameters and tissue environmental conditions2026-04-30T09:51:53ZIn conventional radiotherapy, the probability of controlling tumor growth is quantified using Tumor Control Probability (TCP) models. Instead, the probability of experiencing a side effect after the irradiation of healthy tissues and organs is typically assessed using the concept of Normal Tissue Complication Probability (NTCP), an additional crucial metric for evaluating and comparing treatment plans.
This work is dedicated to the development, implementation, and application of a general mechanistic model to describe the effects of particle therapy (PT) on different tissue organizations beyond Poissonian assumptions, extending the Generalized Stochastic Microdosimetric Model (GSM2), i.e., a stochastic radiobiological model that describes the time evolution of DNA lesions in a cell nucleus according to microdosimetric principles, to the study of macroscopic biological systems. Specifically, we extend the biological stage of radiation damage of the GSM2 model to larger spatial and temporal scales, involving cell populations with a specific geometric and functional architecture.
The model's single-cell resolution allows it to account for energy deposition and tissue heterogeneity, considering different organ volume effects, cell type distributions, and oxygen gradients for different radiation qualities of the beam, that is, type, energy, and LET of radiation, and various fractionation schemes. We show the interplay between physical and environmental parameters on the induction of side effects on healthy tissues, for different radiation qualities and fractionation schemes, and we highlight the impact of biochemical heterogeneities in the target environment, for tumor response.2026-04-30T09:51:53ZMarco BattestiniJules MorandGiulio BordieriMarta MissiaggiaEmanuele ScifoniFrancesco G. Cordonihttp://arxiv.org/abs/2506.15469v3Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays2026-04-30T05:49:31ZAccurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.2025-06-18T13:59:53ZHenri LeroyAdrien BertoloGuillaume GoudotMickael TanterThomas DeffieuxMathieu Pernothttp://arxiv.org/abs/2604.27428v1Wave-Equation Migration Velocity Analysis for Multistatic Synthetic Aperture Ultrasound2026-04-30T05:06:42ZSound speed heterogeneities can create aberrations in B-mode ultrasound images by inducing tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. By using the Fourier split-step method to simulate pressure fields in heterogenous sound speed media, reverse-time migration (RTM) can reconstruct the B-mode image by cross-correlating transmitted and received pressure fields. As a result, RTM is differentiable with respect to sound speed. This enables the reconstruction of the sound speed profile that minimizes the aberration in the B-mode image. In seismic imaging, this form of diffraction tomography, known as wave-equation migration velocity analysis, can roughly be understood as a type of full-waveform inversion (FWI) that acts in the image domain rather than errors in the received channel data. This is the first work applying WEMVA to medical pulse-echo ultrasound imaging. Phantom experiments show dramatic improvements in image quality with measured improvements in point target resolution from 1.22$\pm$1.01 to 0.32$\pm$0.07 mm and lesion contrast from 3.05 to 4.39 dB.2026-04-30T05:06:42Z12 pages, 7 figures, will be submitted to IEEE Transactions on Ultrasonics for peer reviewRehman AliTrevor M. MitchamMarvin M. DoyleyNebojsa DuricJeremy J. Dahlhttp://arxiv.org/abs/2509.09513v2Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner2026-04-29T22:36:36ZBiophysical diffusion MRI models like Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities, neurite fraction, and exchange time. However, NEXI's multi-shell, multi-diffusion-time requirements cause prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, cutting scan time from 27 to 14 minutes. Validated in vivo in seven healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cram'er-Rao Lower Bound (CRLB) theoretical optimum, and two heuristics ("Mid-Range" and "Corner"). It robustly reproduced parameter estimates and maintained test-retest reproducibility. Remarkably, the XAI selection converged to the CRLB optimum. This validates XAI's optimality while highlighting its main advantage: achieving gold-standard optimization without complex analytical Jacobians, making it easily adaptable to numerical models or complex noise where CRLB is intractable. Furthermore, XAI showed superior in vivo robustness over heuristics: "Mid-Range" sampling yielded biased exchange time estimates from insufficient temporal diversity, while "Corner" sampling gave unstable intra-neurite diffusivity estimates (5-fold higher CV) due to noise sensitivity. Ultimately, this robust 14-minute protocol accelerates exchange-sensitive microstructural mapping, establishing a model-agnostic optimization framework adaptable to future ultra-high gradient systems and existing clinical scanners.2025-09-11T14:53:26ZSubmitted to Imaging Neuroscience. This all-in-one version includes supplementary materials. 34 pages, 145 figures, 4 tablesQuentin UhlTommaso PavanJulianna GeroldKwok-Shing ChanYohan JunShohei FujitaAneri BhattYixin MaQiaochu WangHong-Hsi LeeSusie Y. HuangBerkin BilgicIleana Jelescuhttp://arxiv.org/abs/2604.26658v1Simulation of complex DNA damage enhancement and biological effect validation for Proton-CAT2026-04-29T13:24:33ZProton therapy has been rapidly advancing due to its excellent conformal index, but its relatively low relative biological effect (RBE) has somewhat limited its therapeutic efficacy for certain tumors. To address this, we previously proposed a nitrogen-targeting Proton-Carbon-Alpha-Therapy (Proton-CAT) enhancement method. In this letter, we present combined multi-scale DNA damage simulations and in vitro cell experiments, further investigating the mechanism of the Proton-CAT. It has been show that $^{15}$N enrichment significantly enhances complex DNA damage induced by high linear energy transfer(LET) particles within tumor regions. Under 30\% $^{15}$N conditions, $α$ and $^{12}$C particle induced DSB++ increased by 175.19\% and 52.94\%, respectively. Furthermore, in vitro cell experiments using $^{15}$N-glutamine ($^{15}$N-Glu) as the $^{15}$N carrier indicated that high concentrations of $^{15}$N-Glu did not bring about significant cytotoxicity. Following 2 Gy irradiation, the cell viability in the 500 $μ$g/mL $^{15}$N-Glu treated group exhibited a net reduction of about 15.41\% compared to the control group.This indicates that the enhanced effect of Proton-CAT primarily stems from increased complex DNA damage. This work provides a theoretical basis and multi-scale research framework for the development of the Proton-CAT.2026-04-29T13:24:33Z5 pages, 5 figuresLang DongDechao AnJunxiang WuTianle WangZhao SunJiajun KangXianliang WangLintao LiShun LuTianli QiuDa ZhangZhencen HeZhimin Huhttp://arxiv.org/abs/2509.04933v2Characterization of a novel plastic scintillation detector for in vivo electron dosimetry2026-04-29T12:40:03ZIntroduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the radiation field. This study characterizes a novel PSD in an electron beam to determine its suitability for in vivo dosimetry. Methods: Dual-channel Cherenkov radiation correction and dosimetric characterization of the PSD were investigated using reference ionization chambers. Percentage depth-dose curves, lateral profiles, and output factors were compared with reference ionization chamber measurements. Surface doses were measured on solid water and on an anthropomorphic phantom and were compared to ionization chamber and radiochromic film measurements. Results: The investigated PSD demonstrated clinically acceptable linearity, dose rate independence, isotropy and reproducibility (total variation <2%). Dosimetric deviation in R50 and R80 were below 1.0 mm and lateral profiles agreed with a mean absolute error below 1.5%. Small field measurements were within 2% of the reference ionization chamber results. Surface dose measurements had mean relative deviations of 1.3% from ionization chamber measurements and 2.1% from radiochromic film measurements. Conclusion: The PSD investigated in this study is suitable for clinically acceptable electron beam dosimetry and provides accurate dosimetric results for surface dose measurements. It has the potential to be used for real-time in vivo dosimetry.2025-09-05T08:55:29Z15 pages, 5 figures, to be published in Journal of Applied Clinical Medical PhysicsJournal of Applied Clinical Medical Physics 27, e70623 (2026)Cornelius J. BauerFrank SchneiderIda D. GöbelHans OppitzFrank A. GiordanoJens Fleckenstein10.1002/acm2.70623http://arxiv.org/abs/2512.23726v2q3-MuPa: Quick, Quiet, Quantitative Multi-Parametric MRI using Physics-Informed Diffusion Models2026-04-29T08:38:18ZThe 3D fast silent multi-parametric mapping sequence with zero echo time (MuPa-ZTE) is a novel quantitative MRI (qMRI) acquisition that enables nearly silent scanning by using a 3D phyllotaxis sampling scheme. MuPa-ZTE improves patient comfort and motion robustness, and generates quantitative maps of T1, T2, and proton density using the acquired weighted image series. In this work, we propose a diffusion model-based qMRI mapping method that leverages both a deep generative model and physics-based data consistency to further improve the mapping performance. Furthermore, our method enables additional acquisition acceleration, allowing high-quality qMRI mapping from a fourfold-accelerated MuPa-ZTE scan (approximately 1 minute). Specifically, we trained a denoising diffusion probabilistic model (DDPM) to map MuPa-ZTE image series to qMRI maps, and we incorporated the MuPa-ZTE forward signal model as an explicit data consistency (DC) constraint during inference. We compared our mapping method against a baseline dictionary matching approach and a purely data-driven diffusion model. The diffusion models were trained entirely on synthetic data generated from digital brain phantoms, eliminating the need for large real-scan datasets. We evaluated on synthetic data, a NISM/ISMRM phantom, healthy volunteers, and a patient with brain metastases. The results demonstrated that our method produces 3D qMRI maps with high accuracy, reduced noise and better preservation of structural details. Notably, it generalised well to real scans despite training on synthetic data alone. The combination of the MuPa-ZTE acquisition and our physics-informed diffusion model is termed q3-MuPa, a quick, quiet, and quantitative multi-parametric mapping framework, and our findings highlight its strong clinical potential.2025-12-19T08:44:26ZShishuai WangFlorian WiesingerNoemi SgambelluriCarolin PirklStefan KleinJuan A. Hernandez-TamamesDirk H. J. Poothttp://arxiv.org/abs/2604.21173v2Explicit positronium source modeling for Geant4 PET pipelines: controlled 2-gamma and 3-gamma generation and validation2026-04-28T13:49:00ZAn explicit positronium (Ps) source model was implemented in Geant4 to provide direct event-level control over annihilation channel selection, decay timing, and photon emission topology. The implementation supports direct annihilation, para-positronium (p-Ps), and ortho-positronium (o-Ps) branches with user-defined fractions, explicit routing of o-Ps events to two-photon (2-gamma) or three-photon (3-gamma) decay, exponential or fixed delay sampling, optional prompt-photon emission, and optional positron-range displacement. Event-level truth metadata were retained to support downstream validation and analysis. The implementation was evaluated in controlled Geant4 studies using native reference configurations, explicit branch-fraction sweeps, lifetime sweeps, timing benchmarks, and a frozen point-source downstream test harness. Observed 2-gamma and 3-gamma fractions followed the requested control parameters with the expected linear behavior, and measured mean delays reproduced the prescribed lifetime settings with near one-to-one agreement. Computational cost scaled linearly with event count, with modest overhead relative to native Geant4 operation. A minimal downstream validation framework was used to verify branch-consistent handling of pure and mixed datasets, including expected method-source compatibility and recovery of valid events under unified 2-gamma and 3-gamma routing. These results establish a practical and internally consistent code framework for explicit positronium modeling in Geant4 and provide a simple pathway for PET researchers to incorporate controlled Ps generation into existing simulation pipelines.2026-04-23T00:41:16ZJason G ParkerDepartment of Radiology and Imaging Sciences, Indiana University School of Medicinehttp://arxiv.org/abs/2604.25364v1Effect of the dose distribution and organ architecture on the toxicity in FLASH radiotherapy: a modeling study2026-04-28T08:31:31ZObjective: This study aims to investigate the influence of organ architecture (specifically the distinction between serial and parallel tissue) on the protective FLASH effect when organs are irradiated with inhomogeneous dose distributions.
Approach: An in silico modeling framework was developed using two distinct methods to calculate the effective FLASH dose: the first method utilized a biophysical model of radiolytic oxygen depletion (ROD); the second employed a phenomenological logistic function where the effective FLASH dose is a function of local dose and dose rate. Both models assume that the underlying mechanism behind the FLASH effect is local. Normal Tissue Complication Probability (NTCP) for heterogeneous dose distributions was calculated using the Lyman-Kutcher-Burman (LKB) model and the generalized equivalent uniform dose, varying the volume effect parameter n from 1.0 (parallel) to below 0.01 (serial) to explore different architectures.
Results: Both the ROD and phenomenological models showed FLASH sparing compared to conventional radiotherapy. Also, the sparing increased with decreasing $n$ (the sparing is more important for serial organs). For example, for a specific calculation, when the NTCP for conventional radiotherapy was 0.2 (set value) the corresponding NTCP for FLASH delivery ranged from 0.14 for n=1 to 0.11 for n=0.1.
Significance: Our results indicate that if the underlying mechanism/s behind the FLASH effect is/are local, the toxicity sparing associated to FLASH-RT can be dependent on the architecture of the irradiated organ/tissue, being more important for serial organs, which are more sensitive to large local doses than to average doses.2026-04-28T08:31:31ZJuan Pardo-Monterohttp://arxiv.org/abs/2604.25356v1Unsupervised Physics-Informed Deep Learning for Dual-Energy CT Material Decomposition2026-04-28T08:17:29ZDual-energy computed tomography (DECT) enables material-specific imaging through acquisitions at two different X-ray energy spectra. Material decomposition from DECT data is an ill-posed inverse problem that is highly sensitive to noise amplification. Conventional methods face challenges regarding accuracy and computational efficiency. We present a novel physics-informed deep learning (DL) framework for DECT material decomposition that eliminates the requirement for ground-truth material images during training. Our approach incorporates a polychromatic forward model into the training pipeline, enabling the network to learn the decomposition mapping by minimizing discrepancies in the projection domain. We validate our method on the AAPM DL-Spectral CT Challenge dataset, comparing performance against three state-of-the-art methods. In the projection domain, our method achieves the lowest root mean squared error (RMSE) across test datasets. For virtual monoenergetic images (VMIs) at 30 keV, 50 keV, and 70 keV, the approach consistently outperforms all conventional methods in both RMSE and structural similarity index (SSIM). These results demonstrate the potential of DL for accurate material decomposition in DECT without requiring labeled training data.2026-04-28T08:17:29Z12 pages, 4 Figures, 1 TableLaura HellwegeJohann Christopher EngsterMoritz SchaarThorsten M. BuzugMaik Stillehttp://arxiv.org/abs/2604.24704v1Physics-driven innovations toward the democratization of proton therapy2026-04-27T17:08:09ZProton therapy exploits the finite range of charged particles in tissue to achieve dose distributions no photon based modality can replicate. Yet the modality reaches fewer than 1 percent of patients who might benefit a gap rooted in cost and complexity rather than clinical evidence. This Review reframes proton therapy adoption as a physics problem. Two fundamental bottlenecks are identified: cost, arising from scaling laws governing accelerator design, beam transport, and radiation shielding; and motion, arising from the spatiotemporal mismatch between sequential pencil beam scanning and respiratory tumour displacement. We trace how successive compact architectures from gantry-integrated energy selection to gantry mounted accelerators and upright fixed beam systems have progressively reduced facility scale toward LINAC like simplicity and cost-effectiveness. An economic physics framework incorporating fixed and variable operating costs demonstrates that delivery speed has greater leverage on cost per patient than capital cost reduction alone. Field delivery times of approximately 10 seconds now demonstrated across fundamentally different architectures simultaneously suppress the interplay effect and enable the patient throughput required for financial viability. The same physics that resolves the motion problem drives the economic case for broad adoption. Emerging directions, including proton arc therapy, FLASH irradiation, and adaptive delivery define the path toward global democratization of the modality.2026-04-27T17:08:09ZVivek MaradiaMartin Bueshttp://arxiv.org/abs/2604.24639v1Addressing respiratory gating latency for accurate pulse delivery in preclinical electron FLASH irradiation on a clinical linear accelerator2026-04-27T16:08:13ZBackground: Clinical linear accelerators are an accessible platform for preclinical research on the biological effects of ultra rapid electron irradiation (FLASH). However, they are not inherently designed for the accurate pulse control required for experiments using a small number of relatively high-dose pulses, and available methods for beam control such as respiratory gating can be error prone owing to system latency. Here we experimentally characterize the temporal latency of the respiratory gating system for controlling beam-on and beam-off at the individual linac pulse level. Methods and Materials: We used programmable controller boards and a relay circuit to monitor and control delivery of specific numbers of pulses through the built-in monitor chamber and respiratory gating system of a Varian Trilogy linac. We implemented two methods an adaptive method using only the delivered pulse signal, and a synchronization method additionally using the linac internal pulse-timing signal and characterized their performance for standard and customized pulse sequences. Results: Characterizing the latency parameters permitted choosing optimal timing parameters that maximized the rate of successfully delivering the desired number of pulses using both adaptive and synchronization methods. Conclusions: We demonstrated that accounting for latency and/or using the ability to read the prior information on expected pulse timing can provide high accuracy in delivering specified numbers of pulses. This reliability is critical for accurate dose delivery in preclinical FLASH research of single fraction and especially fractionated dosing regimens. The ability to generate custom pulse sequences enables more detailed exploration of the temporal dependence of biological FLASH effects.2026-04-27T16:08:13Z36 pages, 6 figuresRakesh ManjappaJinghui WangStavros MelemenidisVignesh ViswanathanRamish AshrafLawrie SkinnerLuis A. SotoBrianna LauRyan B. KoRie von EybenEdward GravesShu-Jung YuKarl K. BushMurat SurucuErinn B. RankinEmil SchülerPeter G. MaximBilly W. Loohttp://arxiv.org/abs/2604.24437v1Weighted Directional Total Nuclear Variation for Joint Yttrium-90 PET/SPECT Reconstruction with CTAC-derived Guidance2026-04-27T13:03:35ZQuantitative post-treatment activity imaging is essential for personalised dosimetry after Yttrium-90 selective internal radiation therapy (SIRT). Yttrium-90 PET offers high spatial resolution but is extremely low-count, whereas bremsstrahlung SPECT has higher count statistics but is degraded by blur, scatter, and septal penetration. Since both modalities image the same microsphere distribution, joint synergistic reconstruction can exploit their physical coupling, with CT attenuation correction (CTAC) providing additional anatomical guidance.
We propose weighted directional total nuclear variation (w-dTNV), a joint variational regulariser for coupled PET/SPECT reconstruction with CTAC-guided anisotropy. w-dTNV penalises the nuclear norm of a dual-modality Jacobian, promoting co-located, geometry-consistent edges without forcing intensity correlation. Directionality is derived from the CTAC attenuation map $μ$ and applied to PET/SPECT gradients, allowing efficient per-voxel spectral computations. PET/SPECT scale disparity is mitigated using data-driven modality normalisation from preliminary reconstructions.
We evaluate w-dTNV on a NEMA IEC phantom with 20 bootstrapped PET noise realisations and on 9 post-SIRT patients with 45 lesions, against dTV, w-TNV, and sequential hybrid kernel expectation maximisation (SHKEM). In the phantom, w-dTNV improves recovery coefficients over dTV and w-TNV, and improves recovery over SHKEM for the smallest spheres. In patients, w-dTNV gives higher tumour-to-background ratios than SHKEM at comparable background activity. These results suggest that CTAC-guided synergistic variational coupling improves lesion recovery and clinical lesion contrast, offering a practical route towards more stable post-SIRT Yttrium-90 activity estimates for personalised dosimetry.2026-04-27T13:03:35ZS PorterD DeiddaD R McGowanJ Anton-RodriguezS ArridgeK Thielemans