https://arxiv.org/api/PAYm5CfPIc6atSqS8RpAHzPZhiw2026-06-29T02:52:25Z9009160515http://arxiv.org/abs/2502.02771v1When are Diffusion Priors Helpful in Sparse Reconstruction? A Study with Sparse-view CT2025-02-04T23:28:21ZDiffusion models demonstrate state-of-the-art performance on image generation, and are gaining traction for sparse medical image reconstruction tasks. However, compared to classical reconstruction algorithms relying on simple analytical priors, diffusion models have the dangerous property of producing realistic looking results \emph{even when incorrect}, particularly with few observations. We investigate the utility of diffusion models as priors for image reconstruction by varying the number of observations and comparing their performance to classical priors (sparse and Tikhonov regularization) using pixel-based, structural, and downstream metrics. We make comparisons on low-dose chest wall computed tomography (CT) for fat mass quantification. First, we find that classical priors are superior to diffusion priors when the number of projections is ``sufficient''. Second, we find that diffusion priors can capture a large amount of detail with very few observations, significantly outperforming classical priors. However, they fall short of capturing all details, even with many observations. Finally, we find that the performance of diffusion priors plateau after extremely few ($\approx$10-15) projections. Ultimately, our work highlights potential issues with diffusion-based sparse reconstruction and underscores the importance of further investigation, particularly in high-stakes clinical settings.2025-02-04T23:28:21ZAccepted at IEEE ISBI 2025, 5 pages, 2 figures, 1 tableMatt Y. CheungSophia ZorekTucker J. NethertonLaurence E. CourtSadeer Al-KindiAshok VeeraraghavanGuha Balakrishnanhttp://arxiv.org/abs/2502.02677v1Quality assurance and reporting for FLASH clinical trials:the experience of the FEATHER trial2025-02-04T19:36:54ZResearch on ultra-high dose rate (UHDR) radiation therapy has indicated its potential to spare normal tissue while maintaining equivalent tumor control compared to conventional treatments. First clinical trials are underway. The randomized phase II/III FEATHER clinical trial at the Paul Scherrer Institute in collaboration with the University of Zurich Animal Hospital is one of the first curative domestic animal trials to be attempted, and it is designed to provide a good example for human trials. However, the lack of standardized quality assurance (QA) guidelines for FLASH clinical trials presents a significant challenge in trial design. This work aims to demonstrate the development and testing of QA and reporting procedures implemented in the FEATHER clinical trial. We have expanded the clinical QA program to include UHDR-specific QA and additional patient-specific QA. Furthermore, we have modified the monitor readout to enable time-resolved measurements, allowing delivery log files to be used for dose and dose rate recalculations. Finally, we developed a reporting strategy encompassing relevant parameters for retrospective studies. We evaluated our QA and reporting procedures with simulated treatments. This testing confirmed that our QA procedures effectively ensure the correct and safe delivery of the planned dose. Additionally, we demonstrated that we could reconstruct the delivered dose and dose rate using the delivery log files. We developed and used in practice a comprehensive QA and reporting protocol for a FLASH clinical trial at the Paul Scherrer Institute. This work aims to establish guidelines and standardize reporting practices for future advancements in the FLASH-RT field.2025-02-04T19:36:54Z7 figuresIsabella ColizziRobert SchaeferJonas BruecknerGaia DellepianeMartin GrossmannMaximilan KoernerAntony John LomaxDavid MeerBenno RohrerCarla Rohrer BleyMichele TognoSerena Psoroulashttp://arxiv.org/abs/2502.02476v1U-net for spectral quantitative microwave breast imaging2025-02-04T16:52:50ZA spectral approach based on the Fourier diffraction theorem is combined with a pair of U-NETs to perform quantitative microwave imaging of an anthropomorphic breast phantom. The U-NET pair is trained on a spectral database constructed from combinations of different realistic parts of the breast. Some preliminary numerical results are presented to show the major improvement brought by the U-NET.2025-02-04T16:52:50Z7 pages, 8 figuresAmbroise DièsHélène RousselNadine Joachimowiczhttp://arxiv.org/abs/2502.02475v1Style transfer as data augmentation: evaluating unpaired image-to-image translation models in mammography2025-02-04T16:52:45ZSeveral studies indicate that deep learning models can learn to detect breast cancer from mammograms (X-ray images of the breasts). However, challenges with overfitting and poor generalisability prevent their routine use in the clinic. Models trained on data from one patient population may not perform well on another due to differences in their data domains, emerging due to variations in scanning technology or patient characteristics. Data augmentation techniques can be used to improve generalisability by expanding the diversity of feature representations in the training data by altering existing examples. Image-to-image translation models are one approach capable of imposing the characteristic feature representations (i.e. style) of images from one dataset onto another. However, evaluating model performance is non-trivial, particularly in the absence of ground truths (a common reality in medical imaging). Here, we describe some key aspects that should be considered when evaluating style transfer algorithms, highlighting the advantages and disadvantages of popular metrics, and important factors to be mindful of when implementing them in practice. We consider two types of generative models: a cycle-consistent generative adversarial network (CycleGAN) and a diffusion-based SynDiff model. We learn unpaired image-to-image translation across three mammography datasets. We highlight that undesirable aspects of model performance may determine the suitability of some metrics, and also provide some analysis indicating the extent to which various metrics assess unique aspects of model performance. We emphasise the need to use several metrics for a comprehensive assessment of model performance.2025-02-04T16:52:45ZEmir AhmedSpencer A. ThomasCiaran Benchhttp://arxiv.org/abs/2502.02418v1Incorporating Cyclic Group Equivariance into Deep Learning for Reliable Reconstruction of Rotationally Symmetric Tomography Systems2025-02-04T15:38:41ZRotational symmetry is a defining feature of many tomography systems, including computed tomography (CT) and emission computed tomography (ECT), where detectors are arranged in a circular or periodically rotating configuration. This study revisits the image reconstruction process from the perspective of hardware-induced rotational symmetry and introduces a cyclic group equivariance framework for deep learning-based reconstruction. Specifically, we derive a mathematical correspondence that couples cyclic rotations in the projection domain to discrete rotations in the image domain, both arising from the same cyclic group inherent in the hardware design. This insight also reveals the uniformly distributed circular structure of the projection space. Building on this principle, we provide a cyclic rotation equivariant convolution design method to preserve projection domain symmetry and a cyclic group equivariance regularization approach that enforces consistent rotational transformations across the entire network. We further integrate these modules into a domain transform reconstruction framework and validate them using digital brain phantoms, training on discrete models and testing on more complex and realistic fuzzy variants. Results indicate markedly improved generalization and stability, with fewer artifacts and better detail preservation, especially under data distribution deviation. These findings highlight the potential of cyclic group equivariance as a unifying principle for tomographic reconstruction in rotationally symmetric systems, offering a flexible and interpretable solution for scenarios with limited data.2025-02-04T15:38:41ZYaogong ZhangFang-Fang YinLei Zhanghttp://arxiv.org/abs/2501.18433v2A Comparative Dosimetric Study of Proton and Photon Therapy in Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia2025-02-04T01:07:16ZPurpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has shown efficacy, proton therapy offers potential advantages due to its superior dose conformity and sparing of critical OARs, including the heart itself. This study aims to investigate and compare the dosimetry between proton and photon therapy for VT, focusing on target coverage and OAR sparing. Methods: We performed a retrospective study on a cohort of 34 VT patients who received photon STAR. Proton STAR plans were generated using robust optimization in RayStation to deliver the same prescription dose of 25 Gy in a single fraction while minimizing dose to OARs. Dosimetric metrics, including D99, D95, Dmean, and D0.03cc, were extracted for critical OARs and VAS. Shapiro-Wilk tests were used to assess normality, followed by paired t-tests or Wilcoxon signed-rank tests for statistical comparisons between modalities, with Bonferroni correction applied for multiple comparisons. Results: Proton and photon plans achieved comparable target coverage, with VAS D95 of 24.1 +/- 1.2 Gy vs. 24.7 +/- 1.0 Gy (p=0.294). Proton therapy significantly reduced OAR doses, including heart Dmean (3.6 +/- 1.5 Gy vs. 5.5 +/- 2.0 Gy, p<0.001), lungs Dmean (1.6 +/- 1.5 Gy vs. 2.1 +/- 1.4 Gy, p<0.001), and esophagus Dmean (0.3 +/- 0.6 Gy vs. 1.6 +/- 1.3 Gy, p<0.001), while maintaining optimal target coverage. Conclusion: Proton therapy for STAR demonstrates significant dosimetric advantages in sparing the heart and other critical OARs compared to photon therapy for VT, while maintaining equivalent target coverage. These findings highlight the potential of proton therapy to reduce treatment-related toxicity and improve outcomes for VT patients.2025-01-30T15:39:03ZKeyur D. ShahChih-Wei ChangPretesh PatelSibo TianYuan ShaoKristin A HigginsYinan WangJustin RoperJun ZhouZhen TianXiaofeng Yang10.1016/j.phro.2025.100807http://arxiv.org/abs/2411.13087v2Time-resolved diamond magnetic microscopy of superparamagnetic iron-oxide nanoparticles2025-02-03T23:49:37ZSuperparamagnetic iron-oxide nanoparticles (SPIONs) are promising probes for biomedical imaging, but the heterogeneity of their magnetic properties is difficult to characterize with existing methods. Here, we perform widefield imaging of the stray magnetic fields produced by hundreds of isolated ~30-nm SPIONs using a magnetic microscope based on nitrogen-vacancy centers in diamond. By analyzing the SPION magnetic field patterns as a function of applied magnetic field, we observe substantial field-dependent transverse magnetization components that are typically obscured with ensemble characterization methods. We find negligible hysteresis in each of the three magnetization components for nearly all SPIONs in our sample. Most SPIONs exhibit a sharp Langevin saturation curve, enumerated by a characteristic polarizing applied field, B_c. The B_c distribution is highly asymmetric, with a standard deviation (1.4 mT) that is larger than the median (0.6 mT). Using time-resolved magnetic microscopy, we directly record SPION Néel relaxation, after switching off a 31 mT applied field, with a temporal resolution of ~60 ms that is limited by the ring-down time of the electromagnet coils. For small bias fields B_{hold}=1.5-3.5 mT, we observe a broad range of SPION Néel relaxation times--from milliseconds to seconds--that are consistent with an exponential dependence on B_{hold}. Our time-resolved diamond magnetic microscopy study reveals rich SPION sample heterogeneity and may be extended to other fundamental studies of nanomagnetism.2024-11-20T07:28:42ZMain text: 9 pages, 5 figures. Entire manuscript including Appendices: 31 pages, 24 figuresACS nano 19 (10), 10048-10058 (2025)B. A. RichardsN. RistoffJ. SmitsA. Jeronimo PerezI. FescenkoM. D. AielloF. HubertY. SilaniN. MosavianM. Saleh ZiabariA. BerzinsJ. T. DamronP. KehayiasD. EgbebunmiJ. E. ShieldD. L. HuberA. M. MounceM. P. LillyT. KaraulanovA. JarmolaA. LaraouiV. M. Acosta10.1021/acsnano.4c16703http://arxiv.org/abs/2502.01832v1Sparse Measurement Medical CT Reconstruction using Multi-Fused Block Matching Denoising Priors2025-02-03T21:14:19ZA major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement.
Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.2025-02-03T21:14:19ZMaliha HossainYuankai HuoXinqiang YanXiao Wanghttp://arxiv.org/abs/2502.01593v1Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy2025-02-03T18:26:04ZActive breath-hold techniques effectively mitigate respiratory motion but pose challenges for patients who are ineligible for the procedure. Conventional treatment planning relies on multiple energy layers, extending delivery time due to slow layer switching. We propose to use pin ridge filters (pRFs), initially developed for FLASH radiotherapy, to construct a single energy beam plan and minimize dose delivery time. The conventional ITV--based free--breathing treatment plan served as the reference. A GTV--based IMPT--DS plan with a downstream energy modulation strategy was developed based on a new beam model that was commissioned using the maximum energy of the IMPT plan. Consequently, a nested iterative pencil beam direction (PBD) spot reduction process removed low--weighted spots along each PBD, generating pRFs with coarser resolution. Finally, the IMPT--DS plan was then converted into an IMPT--pRF plan, using a monoenergetic beam with optimized spot positions and weights. This approach was validated on lung and liver SBRT cases (10 Gy RBE x 5). For the lung case, the mean lung--GTV dose decreased from 10.3 Gy to 6.9 Gy, with delivery time reduced from 188.79 to 36.16 seconds. The largest time reduction was at 150°, from 47.4 to 3.99 seconds. For the liver case, the mean liver--GTV dose decreased from 5.7 Gy to 3.8 Gy, with delivery time reduced from 111.13 to 30.54 seconds. The largest time reduction was at 180°, from 38.57 to 3.94 seconds. This method significantly reduces dose delivery time and organ at risk dose. Further analysis is needed to validate its clinical feasibility.2025-02-03T18:26:04Z14 pages, 4 figure, 1 tableAhmal Jawad ZafarXiaofeng YangYinan WangZachary DiamondJun Zhouhttp://arxiv.org/abs/2502.01509v1Proposal and Evaluation of a Practical CBCT Dose Optimization Method2025-02-03T16:45:46ZObjective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments.
Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default CBCT protocols (HEAD, PELVIS, LARGE PELVIS, THORAX, SPOTLIGHT) on a Varian TrueBeam linac. Imaging parameters were modified to reduce cumulative exposure by reducing projections (by 25%, 50%, 75%) in FDK reconstruction, or lowering single frame exposure by 25%, 50%, 70 to 75%. Cone Beam Dose Index (CBDI) and weighted CBDI (CBDI_w) were measured in CTDI phantoms to correlate with Kair. Image quality was assessed quantitatively (HU linearity, uniformity, low-contrast visibility, high-contrast resolution, spatial integrity) using Catphan604, and qualitatively via anthropomorphic phantoms.
Results: A linear relationship between Kair, CTDI, and CBDI_w was established. High-contrast resolution and spatial integrity were unaffected by dose reduction (R < 0.5), while low-contrast visibility strongly correlated with exposure (R > 0.75). HU uniformity and linearity remained stable (<40 HU deviation), except for LARGE PELVIS at <50% single-frame exposure. 80 to 50% dose reduction retained clinically acceptable image quality with minimal artifacts or noise.
Significance: CBCT protocols on TrueBeam linacs were optimized for dose reduction. The method enables easy implementation by radiotherapy physicists without diagnostic physics equipment or expertise.2025-02-03T16:45:46ZS. GrosDepartment of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Maywood ILJ. BianDepartment of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Chicago, Maywood ILJ. JacksonDepartment of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Maywood ILM. DelafuenteDepartment of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Maywood ILH. KangDepartment of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Maywood ILW. SmallDepartment of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Maywood ILM. MaheshJohns Hopkins University School of Medicine, Baltimore MDhttp://arxiv.org/abs/2411.16450v2Model-Based Perfusion Reconstruction with Time Separation Technique in Cone-Beam CT Dynamic Liver Perfusion Imaging2025-02-03T14:07:06ZThe success of embolisation, a minimally invasive treatment of liver cancer, could be evaluated in the operational room with cone-beam CT by acquiring a dynamic perfusion scan. The reconstruction algorithm must address the issues of low temporal sampling and higher noise levels inherent in cone-beam CT systems, compared to conventional CT. Therefore, a model-based perfusion reconstruction based on the time separation technique (TST) was applied. TST uses basis functions to model time attenuation curves. These functions are either analytical or based on prior knowledge, extracted using singular value decomposition from CT perfusion data. To explore how well the prior knowledge can model perfusion dynamics and what the potential limitations are, the dynamic CBCT perfusion scan was simulated under different noise levels. The TST method was compared to static reconstruction. It was demonstrated that a set consisting of only four basis functions results in perfusion maps that preserve relevant information, denoises the data, and outperforms static reconstruction under higher noise levels. TST with prior knowledge would not only outperform static reconstruction, but also the TST with analytical basis functions. Furthermore, it has been shown that only eight CBCT rotations, unlike previously assumed ten, are sufficient to obtain the perfusion maps comparable to the reference CT perfusion maps. This contributes to saving dose and reconstruction time. The real dynamic CBCT perfusion scan, reconstructed under the same conditions as the simulated scan, shows potential for maintaining the accuracy of the perfusion maps. By visual inspection, the embolised region was matching to that in corresponding CT perfusion maps. Further analysis of a larger cohort of patient data is needed to draw final conclusions regarding the expected advantages of the time separation technique.2024-11-25T14:59:10ZMedical Physics Received: 2 August 2024 Revised: 20 November 2024 Accepted: 27 December 2024Hana HaseljićInstitute for Medical Engineering, Otto von Guericke University Magdeburg, GermanyResearch Campus STIMULATE, Otto von Guericke University Magdeburg, GermanyRobert FryschInstitute for Medical Engineering, Otto von Guericke University Magdeburg, GermanyResearch Campus STIMULATE, Otto von Guericke University Magdeburg, GermanyVojtěch KulvaitInstitute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, GermanyThomas WernckeInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, GermanyResearch Campus STIMULATE, Otto von Guericke University Magdeburg, GermanyInga BruschInstitute for Laboratory Animal Science, Hannover Medical School, Hannover, GermanyOliver SpeckResearch Campus STIMULATE, Otto von Guericke University Magdeburg, GermanyJessica SchulzSiemens Healthineers AG, Forchheim, GermanyResearch Campus STIMULATE, Otto von Guericke University Magdeburg, GermanyMichael ManhartSiemens Healthineers AG, Forchheim, GermanyGeorg RoseInstitute for Medical Engineering, Otto von Guericke University Magdeburg, GermanyResearch Campus STIMULATE, Otto von Guericke University Magdeburg, Germany10.1002/mp.17652http://arxiv.org/abs/2404.08748v5Multibranch Generative Models for Multichannel Imaging with an Application to PET/CT Synergistic Reconstruction2025-02-03T11:40:31ZThis paper presents a novel approach for learned synergistic reconstruction of medical images using multibranch generative models. Leveraging variational autoencoders (VAEs), our model learns from pairs of images simultaneously, enabling effective denoising and reconstruction. Synergistic image reconstruction is achieved by incorporating the trained models in a regularizer that evaluates the distance between the images and the model. We demonstrate the efficacy of our approach on both Modified National Institute of Standards and Technology (MNIST) and positron emission tomography (PET)/computed tomography (CT) datasets, showcasing improved image quality for low-dose imaging. Despite challenges such as patch decomposition and model limitations, our results underscore the potential of generative models for enhancing medical imaging reconstruction.2024-04-12T18:21:08Z12 pages, 17 figures, 2 tables, submitted to IEEE TRPMSNoel Jeffrey PintonAlexandre BousseCatherine Cheze-Le-RestDimitris Visvikis10.1109/TRPMS.2025.3532176http://arxiv.org/abs/2502.01011v1An Adaptive Proton FLASH Therapy Using Modularized Pin Ridge Filter2025-02-03T03:02:52ZIn this paper, we proposed a method to optimize adaptive proton FLASH therapy (ADP FLASH) using modularized pin ridge filters (pRFs) by recycling module pins from the initial plan while reducing pRF adjustments in adaptive FLASH planning. Initially, single energy (250 MeV) FLASH pRF plans were created using pencil beam directions (PBDs) from initial IMPT plans on the planning CT (pCT). PBDs are classified as new/changed ($Δ$E > > 5 MeV) or unchanged by comparing spot maps for targets between pCT and re-CT. We used an iterative least square regression model to identify recyclable PBDs with minimal relative changes to spot MU weighting. Two PBDs with the least square error were retrieved per iteration and added to the background plan, and the remaining PBDs were reoptimized for the adaptive plan in subsequent iterations. The method was validated on three liver SBRT cases (50 Gy in 5 fractions) by comparing various dosimetric parameters across initial pRF plans on pCT, reCT and the ADP FLASH pRF plans on reCT. V100 for initial pRF plans on pCT, reCT, and ADP FLASH pRF plans for the three cases were as follows: (93.7%, 89.2%, 91.4%), (93.5%, 60.2%, 91.7%), (97.3%, 69.9%, 98.8%). We observe a decline in plan quality when applying the initial pRF to the reCT, whereas the ADP FLASH pRF approach restores quality comparable to the initial pRF on the pCT. FLASH effect of the initial pRF and ADP pRF plans were evaluated with a dose and dose rate threshold of 1Gy and 40Gy/s, respectively, using the FLASH effectiveness model. The proposed method recycled 91.2%, 71%, and 64.7% of PBDs from initial pRF plans for the three cases while maintaining all clinical goals and preserving FLASH effects across all cases.2025-02-03T03:02:52Z20 pages, 4 figuresAhmal Jawad ZafarXiaofeng YangZachary DiamondTian SiboDavid YuPretesh R. PatelJun Zhouhttp://arxiv.org/abs/2502.00741v1Fabrication of Fibers with Complex Features Using Thermal Drawing of 3D-Printed Preforms2025-02-02T10:28:27ZHigh-aspect-ratio polymer materials are widely utilized in applications ranging from everyday materials such as clothing to specialized equipment in industrial and medical fields. Traditional fabrication methods, such as extrusion and molding, face challenges in integrating diverse materials and achieving complex geometries. Additionally, these methods are limited in their ability to provide low-cost and rapid prototyping, which are critical for research and development processes. In this work, we investigated the use of commercially available 3D printers to fabricate fiber preforms, which were subsequently thermally drawn into fibers. By optimizing 3D printing parameters, we achieved the fabrication of fibers with diameters as small as 200 um having complex shapes, with features down to a few microns. We demonstrated the versatility of this method by fabricating fibers from diverse set of materials, such as fibers with different stiffnesses and fibers with magnetic characteristics, which are beneficial for developing tendon-driven and magnetically actuated robotic fibers. In addition, by designing novel preform geometries, we produced tapered fibers and fibers with interlocking mechanisms, also tailored for use in medical steerable catheter applications. These advancements highlight the scalability and versatility of this approach, offering a robust platform for producing high-precision polymer fibers for diverse applications.2025-02-02T10:28:27ZAli Anil DemircaliJinshi ZhaoAyhan AktasMohamed EMK AbdelazizBurak Temelkuranhttp://arxiv.org/abs/2501.14158v2Advancing MRI Reconstruction: A Systematic Review of Deep Learning and Compressed Sensing Integration2025-02-01T14:38:16ZMagnetic resonance imaging (MRI) is a non-invasive imaging modality and provides comprehensive anatomical and functional insights into the human body. However, its long acquisition times can lead to patient discomfort, motion artifacts, and limiting real-time applications. To address these challenges, strategies such as parallel imaging have been applied, which utilize multiple receiver coils to speed up the data acquisition process. Additionally, compressed sensing (CS) is a method that facilitates image reconstruction from sparse data, significantly reducing image acquisition time by minimizing the amount of data collection needed. Recently, deep learning (DL) has emerged as a powerful tool for improving MRI reconstruction. It has been integrated with parallel imaging and CS principles to achieve faster and more accurate MRI reconstructions. This review comprehensively examines DL-based techniques for MRI reconstruction. We categorize and discuss various DL-based methods, including end-to-end approaches, unrolled optimization, and federated learning, highlighting their potential benefits. Our systematic review highlights significant contributions and underscores the potential of DL in MRI reconstruction. Additionally, we summarize key results and trends in DL-based MRI reconstruction, including quantitative metrics, the dataset, acceleration factors, and the progress of and research interest in DL techniques over time. Finally, we discuss potential future directions and the importance of DL-based MRI reconstruction in advancing medical imaging. To facilitate further research in this area, we provide a GitHub repository that includes up-to-date DL-based MRI reconstruction publications and public datasets-https://github.com/mosaf/Awesome-DL-based-CS-MRI.2025-01-24T01:07:58ZarXiv admin note: substantial text overlap with arXiv:2405.00241Mojtaba SafariZach EidexChih-Wei ChangRichard L. J. QiuXiaofeng Yang10.1016/j.bspc.2025.108291