https://arxiv.org/api/z9wjV2Kz7ybIm+A2z0P9Sz8gOZo2026-06-29T01:49:31Z9009159015http://arxiv.org/abs/2502.08480v1Impact of Electric Spatially Discordant Alternans on Cardiac Magnetic Field2025-02-12T15:14:25ZSpatially discordant alternans (SDA) play a crucial role in cardiac arrhythmogenesis by creating steep repolarization gradients facilitating conduction block and reentry. While traditionally studied using electrical indicators, this work provides a novel perspective by characterizing SDA through their magnetic field signatures. Using a one-dimensional cardiac fiber model, we demonstrate that magnetic field measurements effectively detect SDA and temperature dependent changes in cardiac action potentials, offering a non-invasive alternative to conventional electrophysiological metrics. Our results reveal that the spatial organization of SDA is mirrored in the magnetic field distribution, with SDA nodes clearly identifiable via spatial mapping. Notably, magnetic restitution curves exhibit a distinct pattern from APD-based indicators, closely following the dynamics of the action potential upstroke. These findings establish the cardiac magnetic field as a powerful diagnostic tool for detecting SDA, opening new avenues for biomagnetic monitoring of arrhythmic risk.2025-02-12T15:14:25ZMartina NicolettiAnna CrispinoAlessandro LoppiniAlessio GizziLetizia ChiodoChristian CherubiniSimonetta Filippihttp://arxiv.org/abs/2502.07565v1Numerical Study on Human Brain Cortical Electrostimulation Assessment During Uniform Magnetic Field Exposure at Intermediate Frequencies2025-02-11T14:05:04ZObjectives: Permissible limits have been established by international guidelines and standards for human protection to electromagnetic field exposure to prevent adverse health effects stemming from electrostimulation in the most sensitive body part. That is the peripheral nervous system (PNS) in the intermediate frequency range (300 Hz to 100 kHz) and the central nervous system (CNS) at lower frequencies. However, there is a need to reevaluate protection limits against CNS electrostimulation in the intermediate frequency range, considering the importance of brain tissues during electromagnetic head exposure. This study aims to derive the level of CNS cortical stimulation to evaluate compliance with existing protection limits. Method: Multi-scale computation modelling was used to evaluate neuron stimulation thresholds by integrating individual neurons into realistic anatomical head models. Five different excitable membrane models within the motor cortex were examined across three human head models, providing the most comprehensive and extensive evaluation to date. Results: Current protection limits are confirmed as conservative, with non-compliance observed in only 0.02% and 2.4% of axons under clamped and sealed boundary conditions, respectively. The study highlights significant intersubject variability (up to 600% mean threshold) and clarifies the influence of neural excitation models on permissible level assessments. Conclusion: Current electric field limits are conservative for CNS electrostimulation in the intermediate frequencies range, but the margin of safety decreases at higher frequencies, warranting further evaluation. Impact: The findings and methodology contribute to the rationale and provide valuable insights for revising electromagnetic safety exposure guidelines.2025-02-11T14:05:04Z6 pages, 5 figures, 1 tableJose Gomez-TamesThomas TarnaudWout JosephEmmeric Tanghehttp://arxiv.org/abs/2502.07453v1Compound Mask for Divergent Wave Imaging in Medical Ultrasound2025-02-11T10:53:36ZDivergent wave imaging with coherent compounding allows obtaining broad field of view and higher frame rate with respect to line by line insonification. However, the spatial and contrast resolution crucially depends on the weights applied in the compound phase, whose optimization is often cumbersome and based on trial and error. This study addresses these limitations by introducing a closed-form approach that maps the transmit apodization weights used in synthetic aperture imaging into the compound mask applied to divergent wave imaging. The approach draws inspiration from a successful technique developed for plane wave imaging, leveraging synthetic aperture imaging as a reference due to its superior image quality. It works for both linear and convex geometries and arbitrary spatial arrangements of virtual sources generating divergent waves. The approach has been validated through simulated data using both linear and convex probes, demonstrating that the Full Width at Half Maximum (FWHM) in Divergent Wave Linear Array (DWLA) increased by 7.5% at 20 mm and 9% at 30 mm compared to Synthetic Aperture Linear Array (SALA). For Divergent Wave Convex Array (DWCA), the increase was 1.64% at 20 mm and 26.56% at 30 mm compared to Synthetic Aperture Convex Array (SACA), witnessing the method's effectiveness.2025-02-11T10:53:36ZZahraa AlzeinMarco CroccoDaniele D. Caviglia10.1109/ACCESS.2025.3557085http://arxiv.org/abs/2502.06161v1High-Intensity Helical Flow: A Double-Edged Sword in Coronary Artery Haemodynamics2025-02-10T05:20:41ZThe role of Helical Flow (HF) in human coronary arteries remains uncertain, yet its understanding promises unprecedented insights into atherosclerotic processes. In this study, we investigated the effects of HF and key haemodynamic descriptors in 39 patient-specific left coronary artery trees from the ASOCA dataset, including 20 non-stenosed and 19 stenosed cases. Absolute HF intensity $h_2$ correlated with higher Time-Averaged Endothelial Shear Stress (TAESS) in all vessel segments regardless of stenosis (p < 0.05). In stenosed cases, this correlation was so prominent that the vessel area exposed to adversely low TAESS was reduced (< 0.5 Pa, p = 0.0001), while areas of adversely high TAESS increased (> 4.71 Pa, p < 0.05), coinciding with high $h_2$ regions. This suggests that HF in coronary arteries is not always protective as previously thought. It not only mitigates low TAESS, which is associated with long-term plaque development and restenosis, but also exacerbates adversely high TAESS, which is linked to increased plaque vulnerability and acute events. Our findings redefine the current understanding of helical blood flow's role in cardiovascular atherosclerotic disease processes.2025-02-10T05:20:41ZChi ShenMingzi ZhangHamed KeramatiDiogo AlmeidaSusann Beier10.1098/rsos.242184http://arxiv.org/abs/2502.20406v1Reliability of characterising coronary artery flow with the flow-split outflow strategy: comparison against the multiscale approach2025-02-10T03:35:51ZIn computational modelling of coronary haemodynamics, imposing patient-specific flow conditions is paramount, yet often impractical due to resource and time constraints, limiting the ability to perform a large number of simulations particularly for diseased cases. We aimed to compare coronary haemodynamics quantified using a simplified flow-split strategy with varying exponents against the clinically verified but computationally intensive multiscale simulations under both resting and hyperaemic conditions in arteries with varying degrees of stenosis.
Six patient-specific left coronary artery trees were segmented and reconstructed, including three with severe (>70%) and three with mild (<50%) focal stenoses. Simulations were performed for the entire coronary tree to account for the flow-limiting effects from epicardial artery stenoses. Both a 0D-3D coupled multiscale model and a flow-split approach with four different exponents (2.0, 2.27, 2.33, and 3.0) were used. The resulting prominent haemodynamic metrics were statistically compared between the two methods.
Flow-split and multiscale simulations did not significantly differ under resting conditions regardless of the stenosis severity. However, under hyperaemic conditions, the flow-split method significantly overestimated the time-averaged wall shear stress by up to 16.8 Pa (p=0.031) and underestimate the fractional flow reserve by 0.327 (p=0.043), with larger discrepancies observed in severe stenoses than in mild ones. Varying the exponent from 2.0 to 3.0 within the flow-split methods did not significantly affect the haemodynamic results (p>0.141).
Flow-split strategies with exponents between 2.0 and 3.0 are appropriate for modelling stenosed coronaries under resting conditions. Multiscale simulations are recommended for accurate modelling of hyperaemic conditions, especially in severely stenosed arteries.2025-02-10T03:35:51ZFigure: 6, Table: 2, 27 PagesMingzi ZhangHamed KeramatiRamtin GharleghiSusann Beierhttp://arxiv.org/abs/2502.06125v1A CT Geometry With Multiple Centers Of Rotation For Solving Sparse View Problem2025-02-10T03:24:45ZWith the emergence of CNT (Carbon nanotube), static and instant CT scanning becomes possible. By transforming the traditionally rotated thermal source into a static ring array source composed of multiple CNTs, the imaging system can achieve high temporal resolution in scanning. However, due to the non-negligible packaging size of CNTs, the static CT based on CNTs faces sparse view problem, which affects the image quality by introducing streak artifacts. In this study, we based on the local correlation equation (LCE) to address the sparse view problem of static CT. The LCE is a series of partial differential equations (PDEs) to describe the local correlation of Radon transform in a neighborhood projection domain. Based on LCE, we analyze the characteristic of sparse view projection and propose a scanning geometry with multiple rotation centers, which is different from existing CT devices that acquires the projection around one rotation center. Specifically, in the proposed scanning geometry, the circular ring array X-ray sources is divided into several arcs while the sources of each arc share one rotation center. All rotation centers of the arcs are uniformly distributed on a small circle. The optimal distribution of the rotation centers can be optimized by the radius of the circle. Moreover, to elevate the image quality under the sparse view reconstruction, we employed the LCE to interpolate unmeasured projections. Compared to the single rotation center scheme used in existing CT geometries, the multiple rotation centers scan contributes to a more even projection distribution with same view number. The simulated results demonstrated the efficiency and potential applications of the proposed method in static CT reconstructions.2025-02-10T03:24:45ZJiayu DuanYang LiJianmei CaiXuanqin Mouhttp://arxiv.org/abs/2502.06057v1Neurophysiological correlates to the human brain complexity through $q$-statistical analysis of electroencephalogram2025-02-09T22:33:21ZThe prospects of assessing neural complexity (NC) by $q$-statistics of the systemic organization of different types and levels of brain activity were studied. In 70 adult subjects, NC was assessed via the parameter $q$ of $q$-statistics, applied to the ongoing and EEG and its spectral power of 20 scalp points (channels). The NC were estimated both globally for all channels (AllCh) and locally (for each single channel) in different Functional States (FSs). The values of $q$ was compared among FSs and single channels, as well they were correlated with the power of $θ$ (4-8Hz), $β_1$ (15-25Hz) and others EEG bands, in each FS. The value of $q$ across all FSs was higher for AllCh than for the single channels FSs. Consistently with previous studies, we found a negative correlation between NC and age. The FSs did not influence the $q$ of the EEG in AllCh, although locally the FS modulated $q$ in a consistent manner (e.g., reducing $q$ in posterior sites with eyes closed). The $q$ was correlated positively with the power of the $θ$ and negatively with that of the $β_1$ band in general. These findings support the idea that, as a first approach, $q$-statistics can describe the human NC. The relationship between $q$ and $θ$ power aligns with greater NC during FSs such as listening music and resting with eyes open, which is consistent with high-order representations rather than low-informative attentional tasks (OddBall).2025-02-09T22:33:21Z19 pages and 8 figuresDimitri Marques AbramovDaniel de Freitas QuintanilhaHenrique Santos LimaRoozemeria Pereira CostaCarla Kamil-LeiteVladimir V. LazarevConstantino Tsallishttp://arxiv.org/abs/2502.06041v1A coupled planar transmit RF array for ultrahigh field spine MR imaging2025-02-09T21:44:23ZUltrahigh-field MRI, such as those operating at 7 Tesla, enhances diagnostic capabilities but also presents unique challenges, including the need for advanced RF coil designs to achieve an optimal signal-to-noise ratio and transmit efficiency, particularly when imaging large samples. In this work, we introduce the coupled planar array, a novel technique for high-frequency, large-size RF coil design with enhanced the RF magnetic field (B1) efficiency and transmit performance for ultrahigh-field spine imaging applications. This array comprises multiple resonators that are electromagnetically coupled to function as a single multimodal resonator. The field distribution of its highest frequency mode is suitable for spine imaging applications. Based on the numerical modeling and calculation, a prototype of the coupled planar array was constructed and its performance was evaluated through comprehensive numerical simulations, rigorous RF measurements, empirical tests, and a comparison against a conventional surface coil with the same size and geometry. The results of this study demonstrate that the proposed coupled planar array exhibits superior performance compared to conventional surface coils in terms of B1 efficiency for both transmit (B1+) and receive (B1-) fields, specific absorption rate (SAR), and the ability to operate at high frequencies. This study suggests a promising and efficient approach to the design of high-frequency, large-size RF coils for spine MR imaging at ultrahigh magnetic fields.2025-02-09T21:44:23ZYunkun ZhaoKomlan PayneLeslie YingXiaoliang Zhanghttp://arxiv.org/abs/2405.15098v2Magnetic Resonance Image Processing Transformer for General Accelerated Image Reconstruction2025-02-07T21:02:23ZRecent advancements in deep learning have enabled the development of generalizable models that achieve state-of-the-art performance across various imaging tasks. Vision Transformer (ViT)-based architectures, in particular, have demonstrated strong feature extraction capabilities when pre-trained on large-scale datasets. In this work, we introduce the Magnetic Resonance Image Processing Transformer (MR-IPT), a ViT-based framework designed to enhance the generalizability and robustness of accelerated MRI reconstruction. Unlike conventional deep learning models that require separate training for different acceleration factors, MR-IPT is pre-trained on a large-scale dataset encompassing multiple undersampling patterns and acceleration settings, enabling a unified reconstruction framework. By leveraging a shared transformer backbone, MR-IPT effectively learns universal feature representations, allowing it to generalize across diverse reconstruction tasks. Extensive experiments demonstrate that MR-IPT outperforms both CNN-based and existing transformer-based methods, achieving superior reconstruction quality across varying acceleration factors and sampling masks. Moreover, MR-IPT exhibits strong robustness, maintaining high performance even under unseen acquisition setups, highlighting its potential as a scalable and efficient solution for accelerated MRI. Our findings suggest that transformer-based general models can significantly advance MRI reconstruction, offering improved adaptability and stability compared to traditional deep learning approaches.2024-05-23T23:13:02Z28 pages, 8 figures, 5 tablesGuoyao ShenMengyu LiStephan AndersonChad W. FarrisXin Zhanghttp://arxiv.org/abs/2502.05285v1A self-contact electromechanical framework for intestinal motility2025-02-07T19:42:51ZThis study introduces an advanced multiphysics and multiscale modeling approach to investigate intestinal motility. We propose a generalized electromechanical framework that incorporates contact mechanics, enabling the development of a unique and innovative model for intestinal motility. The theoretical framework includes an electromechanical model coupling a microstructural material model, which describes the intestinal structure, with an electrophysiological model that captures the propagation of slow waves. Additionally, it integrates a self-contact detection algorithm based on a nearest-neighbour search and the penalty method, along with boundary conditions that account for the influence of surrounding organs. A staggered finite element scheme implemented in FEniCS is employed to solve the governing equations using the finite element method. The model is applied to study cases of moderate and severe strangulation hernia, as well as intestinal adhesion syndrome. The results demonstrate that low peristalsis takes place in the pre-strangulation zone. At the same time, very high pressure is recorded in the strangulation zone, and peristaltic contractions persisted in the healthy region. For adhesions, the results indicate a complete absence of peristalsis in the adherent region. The model successfully reproduces both qualitatively and quantitatively propagative contractions in complex scenarios, such as pre- and post-surgical conditions, thereby highlighting its potential to provide valuable insights for clinical applications.2025-02-07T19:42:51ZRené Thierry DjoumessiPietro LenardaAlessio GizziMarco Paggihttp://arxiv.org/abs/2501.01341v4Evaluation of Deep Learning-based Scatter Correction on a Long-axial Field-of-view PET scanner2025-02-07T17:04:22ZObjective: Long-axial field-of-view (LAFOV) positron emission tomography (PET) systems allow higher sensitivity, with an increased number of detected lines of response induced by a larger angle of acceptance. However, this extended angle increases the number of multiple scatters and the scatter contribution within oblique planes. As scattering affects both quality and quantification of the reconstructed image, it is crucial to correct this effect with more accurate methods than the state-of-the-art single scatter simulation (SSS) that can reach its limits with such an extended field-of-view (FOV). In this work, which is an extension of our previous assessment of deep learning-based scatter estimation (DLSE) carried out on a conventional PET system, we aim to evaluate the DLSE method performance on LAFOV total-body PET.
Approach: The proposed DLSE method based on a convolutional neural network (CNN) U-Net architecture uses emission and attenuation sinograms to estimate scatter sinogram. The network was trained from Monte-Carlo (MC) simulations of XCAT phantoms [18F]-FDG PET acquisitions using a Siemens Biograph Vision Quadra scanner model, with multiple morphologies and dose distributions. We firstly evaluated the method performance on simulated data in both sinogram and image domain by comparing it to the MC ground truth and SSS scatter sinograms. We then tested the method on seven [18F]-FDG and seven [18F]-PSMA clinical datasets, and compare it to SSS estimations.
Results: DLSE showed superior accuracy on phantom data, greater robustness to patient size and dose variations compared to SSS, and better lesion contrast recovery. It also yielded promising clinical results, improving lesion contrasts in [18F]-FDG datasets and performing consistently with [18F]-PSMA datasets despite no training with [18F]-PSMA.2025-01-02T16:47:09Z15 pages, 10 figures, 3 tablesBaptiste LaurentAlexandre BousseThibaut MerlinAxel RomingerKuangyu ShiDimitris Visvikis10.1007/s00259-025-07120-6http://arxiv.org/abs/2501.04457v2Enhancing kidney quality assessment: Power Doppler during normothermic machine perfusion2025-02-07T12:55:53ZObjectives: Marginal donor kidneys are increasingly used for transplantation to overcome organ shortage. This study aims to investigate the additional value of Power Doppler (PD) imaging in kidney quality assessment during normothermic machine perfusion (NMP). Methods: Porcine kidneys (n=22) retrieved from a local slaughterhouse underwent 2 hours of NMP. Based on creatinine clearance (CrCl) and oxygen consumption (VO2), the kidneys were classified as functional (n=7) and non-functional (n=15) kidneys. PD imaging was performed at 30, 60, and 120 minutes, and PD metrics, including vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were calculated. Renal blood flow (RBF), CrCl, and VO2 were measured at the same time points during NMP. The metrics were compared utilizing correlation analysis. Results: FI and VFI moderately correlated with CrCl (r=0.537, p<0.0001; r=0.536, p<0.0001, respectively), while VI strongly correlated with VO2 (r=0.839, p<0.0001). At 120 minutes, PD metrics demonstrated the highest diagnostic accuracy for distinguishing functional from non-functional kidneys, with an area under the curve (AUC) of 0.943 for VI, 0.924 for FI, and 0.943 for VFI. Cutoff values of 17% for VI, 50 a.u. for FI, and 9 a.u. for VFI provided 100% specificity and 73% sensitivity to identify non-functional kidneys, with an overall diagnostic accuracy of 82%. Baseline kidney biopsies showed moderate acute tubular necrosis in both groups with no significant differences. Conclusions: PD metrics strongly correlate with renal viability and effectively differentiate functional from non-functional kidneys. PD imaging can be a valuable alternative to RBF during NMP for kidney assessment.2025-01-08T12:25:33ZArtif Organs. Published online March 12, 2025Yitian FangAnton V. NikolaevJeroen EssersGisela AmbagtsheerMarian C. Clahsen-van GroningenRobert C. MinneeRon W. F. de BruinGijs van Soest10.1111/aor.14983http://arxiv.org/abs/2405.08489v5Effects of skull properties on long-pulsed transcranial focused ultrasound transmission2025-02-06T12:28:35ZTranscranial low-intensity focused ultrasound can deliver energy to the brain in a minimally invasive manner for neuromodulation applications. However, continuous sonication through the skull introduces significant wave interactions, complicating precise energy delivery to the target. We present a comprehensive examination of intracranial acoustic fields generated by focused ultrasound transducers and assess the characteristics of cranial bone that affect acoustic transmission. Acoustic field maps were generated at 88 regions of interest across 10 historical and 2 Thiel-embalmed human skull specimens with sonication at frequencies of 220 kHz, 650 kHz, and 1000 kHz. The average peak pressure insertion losses for historical were 3.6$\pm$3.4 dB, 9.3$\pm$3.3 dB, and 14.8$\pm$5.8 dB, respectively, and for Thiel skulls, the respective losses were 2.9$\pm$1.8 dB, 9.4$\pm$2.6 dB, and 17.0$\pm$5.5 dB. The effect of skull thickness, skull density ratio, and skull curvature on intracranial peak pressure, power and focal area was investigated and linear fits produced. Several unfavorable focusing performances were observed in regions with excessive thickness variation. The effects of angulation and spacing between the transducer and the skull were also investigated. Preliminary findings indicate that wave superposition resulting from skull and transducer spacing could lead to a 30-40% uncertainty in peak recorded intracranial pressure.2024-05-14T10:29:20Z39 pages, 8 figuresHan LiSchool of Science and Engineering, University of Dundee, Dundee, UKSchool of Physics, Engineering and Technology, University of York, UKIsla BarnardSchool of Science and Engineering, University of Dundee, Dundee, UKTyler HalliwellSchool of Science and Engineering, University of Dundee, Dundee, UKXinyu ZhangSchool of Medicine, University of Dundee, Dundee, UKAndreas MelzerSchool of Medicine, University of Dundee, Dundee, UKInstitute for Computer Assisted Surgery, University Leipzig, GermanyZhihong HuangSchool of Physics, Engineering and Technology, University of York, UKhttp://arxiv.org/abs/2502.03867v1A necessary condition for the guarantee of the superiorization method2025-02-06T08:28:41ZWe study a method that involves principally convex feasibility-seeking and makes secondary efforts of objective function value reduction. This is the well-known superiorization method (SM), where the iterates of an asymptotically convergent iterative feasibility-seeking algorithm are perturbed by objective function nonascent steps. We investigate the question under what conditions a sequence generated by an SM algorithm asymptotically converges to a feasible point whose objective function value is superior (meaning smaller or equal) to that of a feasible point reached by the corresponding unperturbed one (i.e., the exactly same feasibility-seeking algorithm that the SM algorithm employs.) This question is yet only partially answered in the literature. We present a condition under which an SM algorithm that uses negative gradient descent steps in its perturbations fails to yield such a superior outcome. The significance of the discovery of this negative condition is that it necessitates that the inverse of this condition will have to be assumed to hold in any future guarantee result for the SM. The condition is important for practitioners who use the SM because it is avoidable in experimental work with the SM, thus increasing the success rate of the method in real-world applications.2025-02-06T08:28:41Z17 pages. Accepted for publication in the journal "Optimization Letters". arXiv admin note: text overlap with arXiv:2212.14724Kay BarshadYair CensorWalaa MoursiTyler WeamesHenry Wolkowiczhttp://arxiv.org/abs/2502.03360v1A Beam's Eye View to Fluence Maps 3D Network for Ultra Fast VMAT Radiotherapy Planning2025-02-05T16:56:17ZVolumetric Modulated Arc Therapy (VMAT) revolutionizes cancer treatment by precisely delivering radiation while sparing healthy tissues. Fluence maps generation, crucial in VMAT planning, traditionally involves complex and iterative, and thus time consuming processes. These fluence maps are subsequently leveraged for leaf-sequence. The deep-learning approach presented in this article aims to expedite this by directly predicting fluence maps from patient data. We developed a 3D network which we trained in a supervised way using a combination of L1 and L2 losses, and RT plans generated by Eclipse and from the REQUITE dataset, taking the RT dose map as input and the fluence maps computed from the corresponding RT plans as target. Our network predicts jointly the 180 fluence maps corresponding to the 180 control points (CP) of single arc VMAT plans. In order to help the network, we pre-process the input dose by computing the projections of the 3D dose map to the beam's eye view (BEV) of the 180 CPs, in the same coordinate system as the fluence maps. We generated over 2000 VMAT plans using Eclipse to scale up the dataset size. Additionally, we evaluated various network architectures and analyzed the impact of increasing the dataset size. We are measuring the performance in the 2D fluence maps domain using image metrics (PSNR, SSIM), as well as in the 3D dose domain using the dose-volume histogram (DVH) on a validation dataset. The network inference, which does not include the data loading and processing, is less than 20ms. Using our proposed 3D network architecture as well as increasing the dataset size using Eclipse improved the fluence map reconstruction performance by approximately 8 dB in PSNR compared to a U-Net architecture trained on the original REQUITE dataset. The resulting DVHs are very close to the one of the input target dose.2025-02-05T16:56:17ZSimon ArberetFlorin C. GhesuRiqiang GaoMartin KrausJonathan SackettEsa KuuselaAli Kamen