https://arxiv.org/api/F6leUkXqPATf9gEchhC3qO8xtu02026-06-29T00:44:38Z9008157515http://arxiv.org/abs/2502.11265v1Towards Automatic Identification of Missing Tissues using a Geometric-Learning Correspondence Model2025-02-16T20:43:53ZMissing tissue presents a big challenge for dose mapping, e.g., in the reirradiation setting. We propose a pipeline to identify missing tissue on intra-patient structure meshes using a previously trained geometric-learning correspondence model. For our application, we relied on the prediction discrepancies between forward and backward correspondences of the input meshes, quantified using a correspondence-based Inverse Consistency Error (cICE). We optimised the threshold applied to cICE to identify missing points in a dataset of 35 simulated mandible resections. Our identified threshold, 5.5 mm, produced a balanced accuracy score of 0.883 in the training data, using an ensemble approach. This pipeline produced plausible results for a real case where ~25% of the mandible was removed after a surgical intervention. The pipeline, however, failed on a more extreme case where ~50% of the mandible was removed. This is the first time geometric-learning modelling is proposed to identify missing points in corresponding anatomy.2025-02-16T20:43:53ZPresented in XXth International Conference on the use of Computers in Radiation therapy. Pages 759-762 in XXth ICCR Proceedings, found in https://udl.hal.science/hal-04720234v1Eliana M. Vasquez OsorioEdward Hendersonhttp://arxiv.org/abs/2502.11259v1Exploiting network optimization stability for enhanced PET image denoising using deep image prior2025-02-16T20:27:56ZPET is affected by statistical noise due to constraints on tracer dose and scan duration, impacting both diagnostic performance and quantitative accuracy. While deep learning (DL)-based PET denoising methods have been used to improve image quality, they may introduce over-smoothing, compromising quantitative accuracy. We propose a method for making a DL solution more reliable and apply it to the conditional deep image prior (DIP). We introduce the idea of stability information in the optimization process of conditional DIP, enabling the identification of unstable regions within the network's optimization trajectory. Our method incorporates a stability map, which is derived from multiple intermediate outputs of moderate network at different optimization steps. The final denoised image is then obtained by computing linear combination of the DIP output and the original reconstructed image, weighted by the stability map. Our method effectively reduces noise while preserving small structure details in brain FDG images. Results demonstrated that our approach outperformed existing methods in peak-to-valley ratio and noise suppression across various low-dose levels. Region-of-interest analysis confirmed that the proposed method maintains quantitative accuracy without introducing under- or over-estimation. We applied our method to full-dose PET data to assess its impact on image quality. The results revealed that the proposed method significantly reduced background noise while preserving the peak-to-valley ratio at a level comparable to that of unfiltered full-dose PET images. The proposed method introduces a robust approach to DL-based PET denoising, enhancing its reliability and preserving quantitative accuracy. This strategy has the potential to advance performance in high-sensitivity PET scanners, demonstrating that DL can extend PET imaging capabilities beyond low-dose applications.2025-02-16T20:27:56Z10 pages, 8 figuresPhys. Med. Biol. 70 (2025) 105019Fumio HashimotoKibo OteYuya OnishiHideaki TashimaGo AkamatsuYuma IwaoMiwako TakahashiTaiga Yamaya10.1088/1361-6560/add63fhttp://arxiv.org/abs/2502.11156v1DLBayesian: An Alternative Bayesian Reconstruction of Limited-view CT by Optimizing Deep Learning Parameters2025-02-16T15:10:56ZLimited-view computed tomography (CT) presents significant potential for reducing radiation exposure and expediting the scanning process. While deep learning (DL) methods have exhibited promising results in mitigating streaking artifacts caused by a reduced number of projection views, their generalization remains challenging. In this work, we proposed a DL-driven alternative Bayesian reconstruction method (DLBayesian) that efficiently integrates data-driven priors and data consistency constraints. DLBayesian comprises three stages: group-level embedding, significance evaluation, and individual-level consistency adaptation. Firstly, DL network parameters are optimized to learn how to eliminate the general limited-view artifacts on a large-scale paired dataset. Then, we introduced a significance score to quantitatively evaluate the contribution of parameters in DL models as a guide for the subsequent individual-level adaptation. Finally, in the Bayesian adaptation stage, an alternative Bayesian reconstruction further optimizes the DL network parameters precisely according to the projection data of the target case. We validated DLBayesian with sparse-view (90 views) projections from a circular trajectory CT and a special data missing case from a multi-segment linear trajectory CT. The results underscore DLBayesian's superior generalization capabilities across variations in patients, anatomic structures, and data distribution, as well as excelling in contextual structure recovery compared to networks solely trained via supervised loss. Real experiments on a dead rat demonstrate its capability in practical CT scans.2025-02-16T15:10:56ZChangyu ChenLi ZhangYuxiang XingZhiqiang Chenhttp://arxiv.org/abs/2502.10910v13D printed human skull phantoms for transcranial photoacoustic imaging2025-02-15T21:19:01ZPhotoacoustic (PA) waves are strongly distorted and attenuated in skull bone. To study these effects on PA imaging, we designed and 3D-printed tissue-mimicking phantoms of human skull. We present a comparison of results in phantom and ex vivo skull.2025-02-15T21:19:01Zsubmitted to European Conferences on Biomedical Optics (2025); Open Data at doi.org/10.5281/zenodo.14876160Hannah LindeSaskia MenzerJan LauferThomas Kirchnerhttp://arxiv.org/abs/2309.08381v2On undesired emergent behaviors in compound prostate cancer detection systems2025-02-15T08:47:30ZArtificial intelligence systems show promise to aid in the di- agnostic pathway of prostate cancer (PC), by supporting radiologists in interpreting magnetic resonance images (MRI) of the prostate. Most MRI-based systems are designed to detect clinically significant PC le- sions, with the main objective of preventing over-diagnosis. Typically, these systems involve an automatic prostate segmentation component and a clinically significant PC lesion detection component. In spite of the compound nature of the systems, evaluations are presented assum- ing a standalone clinically significant PC detection component. That is, they are evaluated in an idealized scenario and under the assumption that a highly accurate prostate segmentation is available at test time. In this work, we aim to evaluate a clinically significant PC lesion de- tection system accounting for its compound nature. For that purpose, we simulate a realistic deployment scenario and evaluate the effect of two non-ideal and previously validated prostate segmentation modules on the PC detection ability of the compound system. Following, we com- pare them with an idealized setting, where prostate segmentations are assumed to have no faults. We observe significant differences in the de- tection ability of the compound system in a realistic scenario and in the presence of the highest-performing prostate segmentation module (DSC: 90.07+-0.74), when compared to the idealized one (AUC: 77.93 +- 3.06 and 84.30+- 4.07, P<.001). Our results depict the relevance of holistic evalu- ations for PC detection compound systems, where interactions between system components can lead to decreased performance and degradation at deployment time.2023-09-15T13:15:09ZAccepted in MICCAI 2025, CapTiONErlend Sortland RolfsnesPhilip ThangngatTrygve EftestølTobias NordströmFredrik JäderlingMartin EklundAlvaro Fernandez-Quilez10.1007/978-3-031-73376-5_7http://arxiv.org/abs/2502.10580v1Accelerating Quantitative MRI using Subspace Multiscale Energy Model (SS-MuSE)2025-02-14T22:20:22ZMulti-contrast MRI methods acquire multiple images with different contrast weightings, which are used for the differentiation of the tissue types or quantitative mapping. However, the scan time needed to acquire multiple contrasts is prohibitively long for 3D acquisition schemes, which can offer isotropic image resolution. While deep learning-based methods have been extensively used to accelerate 2D and 2D + time problems, the high memory demand, computation time, and need for large training data sets make them challenging for large-scale volumes. To address these challenges, we generalize the plug-and-play multi-scale energy-based model (MuSE) to a regularized subspace recovery setting, where we jointly regularize the 3D multi-contrast spatial factors in a subspace formulation. The explicit energy-based formulation allows us to use variable splitting optimization methods for computationally efficient recovery.2025-02-14T22:20:22ZYan ChenJyothi Rikhab ChandSteven R. KecskemetiJames H. HolmesMathews Jacobhttp://arxiv.org/abs/2502.19431v1Sequential acquisition of fluorescence signals with changing fluorophore concentrations. Multivariate Curve Resolution with time measurements assistance2025-02-14T19:13:52ZSequential registering of fluorescence signals in conventional Excitation-Emission Matrices (EEMs), followed by modeling based on multilinear properties of the data, requires stable fluorophore concentrations throughout the acquisition of each EEM. Rapid concentration changes, as seen in chromatography or certain kinetics, can disrupt the conventional bilinearity of EEMs. This deviation depends on the relative rates of concentration changes versus spectral scanning speeds. Although entire scans can be slow, individual data points are acquired almost instantaneously, maintaining linear dependencies. Within specific time intervals, concentrations can be assumed constant. By using time-based localization, partial EEM data can be organized into partially filled cubes that allow for the correct modeling of third-order data. Additionally, Multivariate Curve Resolution requires reshaping operations. Two third-order datasets were analyzed using a time-assisted MCR implementation, following a strategy similar to one reported for chromatographic data (LC-EEM) with Parallel Factor Analysis. The second dataset comes from Diclofenac reaction kinetics (Kin-EEM). The results suggest that time-assisted MCR resolves such data effectively. The solutions found were similar to those obtained when processing the same data as cubes. Predictions from calibration models based on MCR results were comparable to those obtained when deriving higher order models from the same data. High degrees of similarity were achieved between resolved and reference spectral profiles. Both chromatographic and kinetic profiles were accurate and physically meaningful. The proposed strategy highlights the potential of incorporating time-based localization to enhance the analysis of fluorescence data in dynamic systems.2025-02-14T19:13:52ZGabriel SianoSofia MoraAgustina SchenoneLeonardo Giovaninihttp://arxiv.org/abs/2502.10322v1Offset geometry for extended field-of-view in multi-contrast and multi-scale X-ray microtomography of lung cancer lobectomy specimens2025-02-14T17:30:12ZX-ray microtomography is a powerful non-destructive technique allowing 3D virtual histology of resected human tissue. The achievable imaging field-of-view, is however limited by the fixed number of detector elements, enforcing the requirement to sacrifice spatial resolution in order to image larger samples. In applications such as soft-tissue imaging, phase-contrast methods are often employed to enhance image contrast. Some of these methods, especially those suited to laboratory sources, rely on optical elements, the dimensions of which can impose a further limitation on the field-of-view. We describe an efficient method to double the maximum field-of-view of a cone-beam X-ray microtomography system, without sacrificing on spatial resolution, and including multi-contrast capabilities. We demonstrate an experimental realisation of the method, achieving exemplary reconstructions of a resected human lung sample, with a cubic voxel of 10.5 $μ$m linear dimensions, across a horizontal field-of-view of 4.3 cm. The same concepts are applied to free-space propagation imaging of a 2.7 mm segment of the same sample, achieving a cubic voxel of 450 nm linear dimensions. We show that the methodology can be applied at a range of different length-scales and geometries, and that it is directly compatible with complementary implementations of X-ray phase-contrast imaging.2025-02-14T17:30:12Z14 pages (inc. references), 5 figuresHarry AllanAdam DohertyCarlos Navarrete-LeónOriol Roche i MorgóYunpeng JiaCharlotte PercivalZoe HagelKate E J OtterChuen Ryan KhawKate GowersHelen HallSam M JanesFleur MonkDavid MooreJoseph JacobMarco Endrizzihttp://arxiv.org/abs/2502.09893v1Dynamic-Computed Tomography Angiography for Cerebral Vessel Templates and Segmentation2025-02-14T03:33:04ZBackground: Computed Tomography Angiography (CTA) is crucial for cerebrovascular disease diagnosis. Dynamic CTA is a type of imaging that captures temporal information about the We aim to develop and evaluate two segmentation techniques to segment vessels directly on CTA images: (1) creating and registering population-averaged vessel atlases and (2) using deep learning (DL). Methods: We retrieved 4D-CT of the head from our institutional research database, with bone and soft tissue subtracted from post-contrast images. An Advanced Normalization Tools pipeline was used to create angiographic atlases from 25 patients. Then, atlas-driven ROIs were identified by a CT attenuation threshold to generate segmentation of the arteries and veins using non-linear registration. To create DL vessel segmentations, arterial and venous structures were segmented using the MRA vessel segmentation tool, iCafe, in 29 patients. These were then used to train a DL model, with bone-in CT images as input. Multiple phase images in the 4D-CT were used to increase the training and validation dataset. Both segmentation approaches were evaluated on a test 4D-CT dataset of 11 patients which were also processed by iCafe and validated by a neuroradiologist. Specifically, branch-wise segmentation accuracy was quantified with 20 labels for arteries and one for veins. DL outperformed the atlas-based segmentation models for arteries (average modified dice coefficient (amDC) 0.856 vs. 0.324) and veins (amDC 0.743 vs. 0.495) overall. For ICAs, vertebral and basilar arteries, DL and atlas -based segmentation had an amDC of 0.913 and 0.402, respectively. The amDC for MCA-M1, PCA-P1, and ACA-A1 segments were 0.932 and 0.474, respectively. Conclusion: Angiographic CT templates are developed for the first time in literature. Using 4D-CTA enables the use of tools like iCafe, lessening the burden of manual annotation.2025-02-14T03:33:04ZShrikanth YadavJisoo KimGeoffrey YoungLei Qinhttp://arxiv.org/abs/2502.09694v1In-Silico Investigation of 3D Quantitative Angiography for Internal Carotid Aneurysms Using Biplane Imaging and 3D Vascular Geometry Constraints2025-02-13T18:20:02ZQuantitative angiography (QA) in two dimensions has been instrumental in assessing neurovascular contrast flow patterns, aiding disease severity and treatment outcome evaluations. However, QA requires high spatio-temporal resolution, restricting its use to digital subtraction angiography (DSA), and is prone to errors in quantification of highly 3D flow patterns. This study examines whether 3D QA information can be recovered by reconstructing four-dimensional (4D) angiography using data from standard clinical imaging protocols. Patient-specific internal carotid aneurysm models were used to generate high-fidelity computational fluid dynamics (CFD) simulations of contrast flow. The resulting 4D angiograms were used to simulate biplane DSA under clinical imaging protocols. 4D angiography was reconstructed from two views using back-projection constrained by an a priori 3D geometry. Quantitative angiographic parametric imaging (API) metrics obtained from the CFD-based 4D angiography and reconstructed 4D angiography were compared using mean square error (MSE) and mean absolute percentage error (MAPE). The reconstructed 4D datasets effectively captured 3D flow dynamics, achieving an average MSE of 0.007 across models and flow conditions. API metrics such as PH and AUC closely matched the CFD ground truth, with temporal metrics showing some variability in regions with overlapping projections. These results demonstrate the potential to recover 3D QA information using simulated 4D angiography constrained by standard clinical imaging parameters. The method provides a robust framework for evaluating and improving QA in clinical neurovascular applications, offering new insights into the dynamics of aneurysmal contrast flow.2025-02-13T18:20:02Z14 pages, 6 figures, 2 tables. Under review in Medical PhysicsKyle A. WilliamsSwetadri Vasan Setlur NageshDaniel R. BednarekStephen RudinCiprian N. Ionitahttp://arxiv.org/abs/2502.09296v1A Physics-Informed Deep Learning Model for MRI Brain Motion Correction2025-02-13T13:09:55ZBackground: MRI is crucial for brain imaging but is highly susceptible to motion artifacts due to long acquisition times. This study introduces PI-MoCoNet, a physics-informed motion correction network that integrates spatial and k-space information to remove motion artifacts without explicit motion parameter estimation, enhancing image fidelity and diagnostic reliability. Materials and Methods: PI-MoCoNet consists of a motion detection network (U-net with spatial averaging) to identify corrupted k-space lines and a motion correction network (U-net with Swin Transformer blocks) to reconstruct motion-free images. The correction is guided by three loss functions: reconstruction (L1), perceptual (LPIPS), and data consistency (Ldc). Motion artifacts were simulated via rigid phase encoding perturbations and evaluated on IXI and MR-ART datasets against Pix2Pix, CycleGAN, and U-net using PSNR, SSIM, and NMSE. Results: PI-MoCoNet significantly improved image quality. On IXI, for minor artifacts, PSNR increased from 34.15 dB to 45.95 dB, SSIM from 0.87 to 1.00, and NMSE reduced from 0.55% to 0.04%. For moderate artifacts, PSNR improved from 30.23 dB to 42.16 dB, SSIM from 0.80 to 0.99, and NMSE from 1.32% to 0.09%. For heavy artifacts, PSNR rose from 27.99 dB to 36.01 dB, SSIM from 0.75 to 0.97, and NMSE decreased from 2.21% to 0.36%. On MR-ART, PI-MoCoNet achieved PSNR gains of ~10 dB and SSIM improvements of up to 0.20, with NMSE reductions of ~6%. Ablation studies confirmed the importance of data consistency and perceptual losses, yielding a 1 dB PSNR gain and 0.17% NMSE reduction. Conclusions: PI-MoCoNet effectively mitigates motion artifacts in brain MRI, outperforming existing methods. Its ability to integrate spatial and k-space information makes it a promising tool for clinical use in motion-prone settings. Code: https://github.com/mosaf/PI-MoCoNet.git.2025-02-13T13:09:55ZMojtaba SafariShansong WangZach EidexRichard QiuChih-Wei ChangDavid S. YuXiaofeng Yang10.1002/mp.70197http://arxiv.org/abs/2405.02477v2Deep Learning-Based Beamlet Model for Generic X-Ray Beam Dose Calculation2025-02-13T11:58:58ZModeling the absorbed dose during X-ray imaging is essential for optimizing radiation exposure. Monte Carlo simulations (MCS) are the gold standard for precise 3D dose estimation but require significant computation time. Deep learning offers faster dose prediction but often lacks generality, as models are typically trained for specific anatomical sites and beam geometries. The aim in this work was proposing a generic deep-learning approach for dose calculation that can be used for multiple X-ray imaging systems. This article proposes a versatile approach combining beamlet decomposition with deep learning, where the X-ray beam is broken down into beamlets. By using a sampling approach, various beam shapes can be generated, reducing learning complexity. The model learns the dose response of a beamlet for different energies and patient properties, making it adaptable to new system geometries without altering the learning model. In this work, we propose combining two U-Net networks (1D+3D) trained on different body parts to predict the dose of a beamlet regardless of its orientation and energy. Results have shown that the deep learning-based dose engine achieved a relative dose error of approximately 1.2+/-3.87% compared to the reference dose. For a more realistic simulation in cone-beam CT, dose results exhibited a relative error within the beam of 5% compared to a full MCS. The convergence of the proposed method was faster compared to MCS, with a speedup of 130 times for equivalent dose results. The versatility of the proposed solution allows for the simulation of multiple X-ray systems without the need to retrain the deep learning model with new beam specificities. The same trained model is capable of calculating the 3D dose within the patient for helical CT, cone-beam CT, fan-beam CT, or any collimated beam shape.2024-05-03T20:37:31Z17 pages, 9 figuresMaxime RousselotJing ZhangDidier BenoitChi-Hieu PhamJulien Berthttp://arxiv.org/abs/2502.08824v1Ultrasound imaging of cortical bone: cortex geometry and measurement of porosity based on wave speed for bone remodeling estimation2025-02-12T22:29:47ZIntracortical US imaging extends B-mode imaging into bone using a dedicated image reconstruction algorithm that corrects for refraction at the bone-soft tissue interfaces. It has shown promising results in a few healthy, predominantly young adults, providing anatomical images of the cortex (periosteal and endosteal surfaces) along with estimations of US wave speed. However, its reliability in older or osteoporotic bones remains uncertain. In this study, we critically assessed the performance of intracortical US imaging ex vivo in bones with various microstructural patterns, including bones exhibiting signs of unbalanced intracortical remodeling. We analyzed factors influencing US image quality, particularly endosteal surface reconstruction, as well as the accuracy of wave speed estimation and its relationship with porosity. We imaged 20 regions of interest from the femoral diaphysis of five elderly donors using a 2.5 MHz US transducer. The reconstructed US images were compared to site-matched high-resolution micro-CT (HR-muCT) images. In samples with moderate porosity, the endosteal surface was accurately identified, and thickness estimates from US and HR-muCT differed by less than 10%. In highly remodeled bones with increased porosity, the reconstructed endosteal surface appeared less bright and was located above the cortex region containing resorption cavities. We observed a decrease in US wave speed with increasing cortical porosity suggesting that the method could discriminate between bones with low porosity (less than 5%) and those with moderate to high porosity (greater than ~10%). This study paves the way for the application of US imaging in diagnosing cortical bone health, particularly for detecting increased cortical porosity and reduced cortical thickness.2025-02-12T22:29:47ZAmadou S. DiaGuillaume RenaudChristine ChappardQuentin Grimalhttp://arxiv.org/abs/2410.18842v2A diffusion MRI model for random walks confined on cylindrical surfaces: Towards non-invasive quantification of myelin sheath radius2025-02-12T16:13:05ZQuantifying the myelin sheath radius of myelinated axons in vivo is important for understanding, diagnosing, and monitoring various neurological disorders. Despite advancements in diffusion MRI (dMRI) microstructure techniques, there are currently no models specifically designed to estimate myelin sheath radii. This proof-of-concept theoretical study presents two novel dMRI models that characterize the signal from water diffusion confined to cylindrical surfaces, approximating myelin water diffusion. We derive their spherical mean signals, eliminating fiber orientation and dispersion effects for convenience. These models are further extended to account for multiple concentric cylinders, mimicking the layered structure of myelin. Additionally, we introduce a method to convert histological distributions of axonal inner radii from the literature into myelin sheath radius distributions. We also derive analytical expressions to estimate the effective myelin sheath radius expected from these distributions. Monte Carlo (MC) simulations conducted in cylindrical and spiral geometries validate the models. These simulations demonstrate agreement with analytical predictions. Furthermore, we observe significant correlations between the effective radii derived from histological distributions and those obtained by fitting the dMRI signal to a single-cylinder model. These models may be integrated with existing multi-compartment dMRI techniques, opening the door to non-invasive in vivo assessments of myelin sheath radii. Such assessments would require MRI scanners equipped with strong diffusion gradients, allowing measurements with short echo times. Further work is required to validate the technique with real dMRI data and histological measurements.2024-10-24T15:26:10Z55 pages, 7 figures, 1 table, manuscript accepted in Frontiers in PhysicsErick J Canales-RodríguezChantal M. W. TaxElda Fischi-GomezDerek K. JonesJean-Philippe ThiranJonathan Rafael-Patiño10.3389/fphy.2025.1516630http://arxiv.org/abs/2502.08480v1Impact of Electric Spatially Discordant Alternans on Cardiac Magnetic Field2025-02-12T15:14:25ZSpatially discordant alternans (SDA) play a crucial role in cardiac arrhythmogenesis by creating steep repolarization gradients facilitating conduction block and reentry. While traditionally studied using electrical indicators, this work provides a novel perspective by characterizing SDA through their magnetic field signatures. Using a one-dimensional cardiac fiber model, we demonstrate that magnetic field measurements effectively detect SDA and temperature dependent changes in cardiac action potentials, offering a non-invasive alternative to conventional electrophysiological metrics. Our results reveal that the spatial organization of SDA is mirrored in the magnetic field distribution, with SDA nodes clearly identifiable via spatial mapping. Notably, magnetic restitution curves exhibit a distinct pattern from APD-based indicators, closely following the dynamics of the action potential upstroke. These findings establish the cardiac magnetic field as a powerful diagnostic tool for detecting SDA, opening new avenues for biomagnetic monitoring of arrhythmic risk.2025-02-12T15:14:25ZMartina NicolettiAnna CrispinoAlessandro LoppiniAlessio GizziLetizia ChiodoChristian CherubiniSimonetta Filippi