https://arxiv.org/api/bbSgsbWzOaljHJzALhhR/C3RHqk2026-06-28T23:29:42Z9008156015http://arxiv.org/abs/2502.15064v1Pseudoinverse Diffusion Models for Generative CT Image Reconstruction from Low Dose Data2025-02-20T21:56:15ZScore-based diffusion models have significantly advanced generative deep learning for image processing. Measurement conditioned models have also been applied to inverse problems such as CT reconstruction. However, the conventional approach, culminating in white noise, often requires a high number of reverse process update steps and score function evaluations. To address this limitation, we propose an alternative forward process in score-based diffusion models that aligns with the noise characteristics of low-dose CT reconstructions, rather than converging to white noise. This method significantly reduces the number of required score function evaluations, enhancing efficiency and maintaining familiar noise textures for radiologists, Our approach not only accelerates the generative process but also retains CT noise correlations, a key aspect often criticized by clinicians for deep learning reconstructions. In this work, we rigorously define a matrix-controlled stochastic process for this purpose and validate it through computational experiments. Using a dataset from The Cancer Genome Atlas Liver Hepatocellular Carcinoma (TCGA-LIHC), we simulate low-dose CT measurements and train our model, comparing it with a baseline scalar diffusion process and conditional diffusion model. Our results demonstrate the superiority of our pseudoinverse diffusion model in terms of efficiency and the ability to produce high-quality reconstructions that are familiar in texture to medical professionals in a low number of score function evaluations. This advancement paves the way for more efficient and clinically practical diffusion models in medical imaging, particularly beneficial in scenarios demanding rapid reconstructions or lower radiation exposure.2025-02-20T21:56:15ZMatthew TivnanDufan WuQuanzheng Lihttp://arxiv.org/abs/2502.15060v1Multi-Source Static CT with Adaptive Fluence Modulation to Minimize Hallucinations in Generative Reconstructions2025-02-20T21:49:50ZMulti-source static Computed Tomography (CT) systems have introduced novel opportunities for adaptive imaging techniques. This work presents an innovative method of fluence field modulation using spotlight collimators. These instruments block positive or negative fan angles of even and odd indexed sources, respectively. Spotlight collimators enable volume of interest imaging by increasing relative exposure for the overlapping views. To achieve high quality reconstructions from sparse-view low-dose data, we introduce a generative reconstruction algorithm called Langevin Posterior Sampling (LPS), which uses a score based diffusion prior and physics based likelihood model to sample a posterior random walk. We conduct simulation-based experiments of head CT imaging for stroke detection and we demonstrate that spotlight collimators can effectively reduce the standard deviation and worst-case scenario hallucinations in reconstructed images. Compared to uniform fluence, our approach shows a significant reduction in posterior standard deviation. This highlights the potential for spotlight collimators and generative reconstructions to improve image quality and diagnostic accuracy of multi-source static CT.2025-02-20T21:49:50ZMatthew TivnanAmar GuptaKai YangDufan WuRajiv Guptahttp://arxiv.org/abs/2502.15055v1Generative Super-Resolution PET Imaging with Fourier Diffusion Models2025-02-20T21:33:19ZNeurological Positron Emission Tomography (PET) is a critical imaging modality for diagnosing and studying neurodegenerative diseases like Alzheimer's disease. However, the inherent low spatial resolution of PET images poses significant challenges in clinical settings. This work introduces a novel Generative Super-Resolution (GSR) approach using Fourier Diffusion Models (FDMs) to enhance the spatial resolution of PET images. Unlike traditional methods, FDMs leverage the time-dependent Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) to generate high-resolution, low-noise images from low-resolution inputs. Our method was evaluated using simulated data derived from High-Resolution Research Tomograph (HRRT) PET images with 2 mm resolution. The results demonstrate that FDMs significantly outperform existing techniques, including conditional diffusion models and image-to-image Schrödinger bridge, across several metrics, including structural similarity and noise suppression. Our simulation results highlight the potential of FDMs to generate high-quality 2mm resolution reconstructions given 4mm resolution input PET data.2025-02-20T21:33:19ZMatthew TivnanQuanzheng Lihttp://arxiv.org/abs/2502.14710v1Instrumented mouthguards in elite sports: Validity and head acceleration event (HAE) incidence in NCAA American Football2025-02-20T16:37:07ZObjectives: To determine the on-field validity of instrumented mouthguards (iMGs) in American football and to quantify head acceleration event (HAE) incidence in NCAA football players. Methods: Instrumented mouthguards were fitted to 35 male NCAA football players. Head kinematic data were collected during 64 player matches. On-field validity was determined through video review with positive predictive value (PPV) and sensitivity values calculated. HAE incidence was calculated as the number of HAEs per player match and stratified by Offense and Defense positions. Results: On-field validity of the Prevent Biometrics iMG in NCAA American Football indicates a sensitivity was 0.89 and PPV ranging from 0.76-0.98 based on false positive definitions. The incidence of PLA and PAA HAEs above a range of thresholds in Defense and Offense appear similar. The incidence of HAEs above 10 g was 11.2 and 11.3 HAEs per player match for Defense and Offense, respectively, while PAA incidence above 1.0 krad/s2 was 5.5 and 6.9 HAEs per player match for Defense and Offense, respectively. Incidence of HAEs above 30 g was 1.6 and 2.6 per player match and 0.9 and 1.4 for HAEs above 2.0 krad/s2 for Defense and Offense, respectively. Conclusion: The Prevent Biometrics iMG appears suitable for measuring HAEs in elite American football. The study provides a benchmark assessment of HAE incidence in elite American Football and lays a foundation for the development of position-specific interventions aimed at reducing HAE exposure.2025-02-20T16:37:07ZMario RotundoNicholas MurrayDavid AllanGregory Tierneyhttp://arxiv.org/abs/2502.13760v2Muscle Activation Estimation by Optimizing the Musculoskeletal Model for Personalized Strength and Conditioning Training2025-02-20T12:33:45ZMusculoskeletal models are pivotal in the domains of rehabilitation and resistance training to analyze muscle conditions. However, individual variability in musculoskeletal parameters and the immeasurability of some internal biomechanical variables pose significant obstacles to accurate personalized modelling. Furthermore, muscle activation estimation can be challenging due to the inherent redundancy of the musculoskeletal system, where multiple muscles drive a single joint. This study develops a whole-body musculoskeletal model for strength and conditioning training and calibrates relevant muscle parameters with an electromyography-based optimization method. By utilizing the personalized musculoskeletal model, muscle activation can be subsequently estimated to analyze the performance of exercises. Bench press and deadlift are chosen for experimental verification to affirm the efficacy of this approach.2025-02-19T14:22:39ZXi WuChenzui LiKehan ZouNing XiFei Chenhttp://arxiv.org/abs/2408.07737v2A Finite Element Analysis Model for Magnetomotive Ultrasound Elastometry Magnet Design with Experimental Validation2025-02-20T04:26:04ZMagnetomotive ultrasound (MMUS) using magnetic nanoparticle contrast agents has shown promise for thrombosis imaging and quantitative elastometry via magnetomotive resonant acoustic spectroscopy (MRAS). Young's modulus measurements of smaller, stiffer thrombi require an MRAS system capable of generating forces at higher temporal frequencies. Solenoids with fewer turns, and thus less inductance, could improve high frequency performance, but the reduced force may compromise results. In this work, a computational model capable of assessing the effectiveness of MRAS elastometry magnet configurations is presented and validated. Finite element analysis (FEA) was used to model the force and inductance of MRAS systems. The simulations incorporated both solenoid electromagnets and permanent magnets in three-dimensional steady-state, frequency domain, and time domain studies. The model successfully predicted that a configuration in which permanent magnets were added to an existing MRAS system could be used to increase the force supplied. Accordingly, the displacement measured in a magnetically labeled validation phantom increased by a factor of $2.2 \pm 0.3$ when the force was predicted to increase by a factor of $2.2 \pm 0.2$. The model additionally identified a new solenoid configuration consisting of four smaller coils capable of providing sufficient force at higher driving frequencies. These results indicate two methods by which MRAS systems could be designed to deliver higher frequency magnetic forces without the need for experimental trial and error. Either the number of turns within each solenoid could be reduced while permanent magnets are added at precise locations, or a larger number of smaller solenoids could be used. These findings overcome a key challenge toward the goal of MMUS thrombosis elastometry, and simulation files are provided online for broader experimentation.2024-08-14T17:55:51Z12 pages, 8 figures. This manuscript has been revised from version v1 via the peer review process. It has been accepted in its current form and is awaiting publication at Biomedical Physics and Engineering ExpressBiomed. Phys. Eng. Express 11 025048 (2025)Jacquelline NyakunuChristopher T. PiatnichoukHenry C. RussellNiels J. van DuijnhovenBenjamin E. Levy10.1088/2057-1976/adb8f0http://arxiv.org/abs/2012.14194v2Finer-Focused Partial Wave Spectroscopy (ff-PWS) and Detection of Cancer Stages From Human Tissue Samples2025-02-19T22:04:46ZThe progression of cancer is associated with different genetic and epigenetic events which result in nano to microscale structural alterations in cells/tissue. However, these structural alterations in the early stage of the disease remain undetectable by conventional microscopy due to the diffraction-limited resolution of ~200nm. With cancer being an epidemic worldwide, early and accurate detection methods are always in demand. In this sense, we developed a finer focusing mesoscopic physics-based partial wave spectroscopy (PWS) imaging and quantification technique, which can probe the precise scattering volume in cells/tissue to detect such structural alterations. Therefore, we employ the highly sensitive PWS technique to quantify the nanoscale refractive index fluctuations using commercially available paraffin embedded tissue microarrays (TMA) samples with the goal of the standardized early and accurate detection of stages of different cancers. Recently the use of scientific TMA samples has gained research interest in diagnosing different diseases and drug-effect in treatment since they are commercially easily accessible. In this work, deadly cancer such as pancreatic, prostate, breast, and colon cancer TMAs containing multiple cores of different stages for each cancer are analyzed using the PWS technique and the degree of disorder strength Ld was quantified. The finer focusing PWS results show that an increase in the disorder strength with the increase in the stage of each cancer. This quantitative analysis of different cancer stages using commercially available TMA samples could enhance and standardize early, accurate cancer diagnosis modalities.2020-12-28T11:20:19Z16 pages, 5 figuresDhruvil SolankiPrakash AdhikariIshmael ApachigawoFatemah AlharthiPrabhakar Pradhanhttp://arxiv.org/abs/2308.10968v3Regularization by Neural Style Transfer for MRI Field-Transfer Reconstruction with Limited Data2025-02-19T16:24:49ZRecent advances in MRI reconstruction have demonstrated remarkable success through deep learning-based models. However, most existing methods rely heavily on large-scale, task-specific datasets, making reconstruction in data-limited settings a critical yet underexplored challenge. While regularization by denoising (RED) leverages denoisers as priors for reconstruction, we propose Regularization by Neural Style Transfer (RNST), a novel framework that integrates a neural style transfer (NST) engine with a denoiser to enable magnetic field-transfer reconstruction. RNST generates high-field-quality images from low-field inputs without requiring paired training data, leveraging style priors to address limited-data settings. Our experiment results demonstrate RNST's ability to reconstruct high-quality images across diverse anatomical planes (axial, coronal, sagittal) and noise levels, achieving superior clarity, contrast, and structural fidelity compared to lower-field references. Crucially, RNST maintains robustness even when style and content images lack exact alignment, broadening its applicability in clinical environments where precise reference matches are unavailable. By combining the strengths of NST and denoising, RNST offers a scalable, data-efficient solution for MRI field-transfer reconstruction, demonstrating significant potential for resource-limited settings.2023-08-21T18:26:35Z27 pages, 9 figures, 3 tables, 1 algorithm chartGuoyao ShenYancheng ZhuMengyu LiRyan McNaughtonHernan JaraSean B. AnderssonChad W. FarrisStephan AndersonXin Zhanghttp://arxiv.org/abs/2412.00904v2On a revised concept of an event that allows linking nanodosimetry and microdosimetry in nanometric sites with macroscopic dosimetry2025-02-19T15:42:11ZThis work reviews the concepts of an event used in micro- and nanodosimetry and analyzes how single event distributions could theoretically be derived from probability distributions related to interactions of the primary particle which produce secondary electrons. It is shown that the corresponding mathematical expressions of conditional ionization cluster size distributions are alike those for the single event frequency distribution of energy imparted, particularly when all tracks are considered which intersect the volume in which interactions of the primary particle can result in energy deposits in the site. Track structure simulations of proton with energies between 1 MeV and 100 MeV are used to study how the occurrence of events depends on site size, beam radius, and proton energy. The range of impact parameters of particle tracks that contribute to energy imparted in a site appears not to depend on whether any energy deposits or only energy deposits by ionizations are considered. Since there is no longer a one-to-one correspondence between tracks passing a site and the occurrence of an event, it is proposed to use the fluence for which on average one event occurs as a substitute for single events. For protons, the product of this fluence and the site cross section or the average number of tracks necessary for an event shows an interesting dependence on site size and particle energy with asymptotic values close to unity for large sites and proton energies below 10 MeV. For a proton energy of 1 MeV, a minimum of the number of tracks is observed for sites between 5 nm and 10 nm diameter. The relative differences between the numbers of track per event on average obtained with different options of Geant4-DNA are in the order of 10 % and illustrate the need for further investigations into cross-section datasets and their uncertainties.2024-12-01T17:37:56Z39 pages, 8 Figs. plus 11 Suppl. FigsRadiation Physics and Chemistry 232; 112640 (2025). Online 23.02.2025Hans RabusLeo Thomas10.1016/j.radphyschem.2025.112640http://arxiv.org/abs/2502.13649v1Pericoronary adipose tissue attenuation as a predictor of functional severity of coronary stenosis2025-02-19T11:50:07ZObjective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid dynamics (CFD) simulations from a prior study. Centerlines of the main epicardial branches were automatically extracted, and lesions identified using Gaussian kernel regression to estimate healthy branch caliber. PCAT features were computed per vessel following guideline recommendations and per lesion within a region extending radially for two vessel radii. Features like fat volume and mean attenuation (FAI) were analyzed for their relationship with CFD-derived hemodynamic biomarkers, such as fractional flow reserve (FFR) and wall shear stress (WSS). These features also informed a machine learning (ML) model for classifying potentially ischemic lesions. Results: PCAT exhibited, on average, higher attenuation in the presence of hemodynamically significant lesions (i.e., FFR < 0.80), although this difference was of limited statistical significance. The ML classifier, trained on PCAT features, successfully distinguished potentially ischemic lesions, yielding average accuracy of 0.84. Conclusion: PCAT attenuation is correlated with the functional status of coronary stenosis and can be used to inform ML models for predicting potential ischemia. Significance: PCAT features, readily available from CCTA, can be used to predict the hemodynamic characteristics of a lesion without the need for an invasive FFR examination.2025-02-19T11:50:07ZMarta PillitteriGuido NanniniSimone SaittaLuca MarianiRiccardo MaragnaAndrea BaggianoGianluca PontoneAlberto Redaellihttp://arxiv.org/abs/2502.11171v2Design and Fabrication of Low Cost Cardiopulmonary Resuscitaion Device | A Novel Mechatronics System2025-02-18T19:34:47ZCardiac arrest is very common nowadays. Sudden heart attack is a condition where the heart suddenly stops beating causing a significant decrease in blood flow to the brain. The first step in medical point of view is for a patient experiencing sudden heart attack is Cardiopulmonary Resuscitation (CPR).Moreover, compression rate needed for CPR process is far beyond for humans to provide manually. So, there is intense need of mechanical device which can perform resuscitation. Cardiopulmonary resuscitation device is used to augment the blood flow and maintain hemodynamic cycle of human body. CPR device is proposed to meet the effective and unique blood flow mechanism, feedback system. In term of effective and unique blood flow mechanism design and fabrication of low cost cardiopulmonary resuscitation device based on principle of CPR and two concepts. It is combined Sterno-Thoracic Cardiopulmonary Resuscitation. The "cardiac pump" generates blood flow by squeezing blood out of the heart as the sternum is depressed. The "thoracic pump" increases intrathoracic pressure due to elastic recoil of ribs. In order to meet the American Heart Association standard guidelines a feedback system has established through closed loop control system, and integration of processing controllers. Specifically, a small HMI (Human machine interface) device has been established to control the whole mechanism which would be used for child, Adults and Senior citizens as a manual intelligence system. Henceforth, feedback system act as backbone for this device.2025-02-16T15:45:11ZNabeel Ahmad Khan Jadoonhttp://arxiv.org/abs/2502.13084v1Quantitative First-Pass Perfusion CMR: from technical principles to clinical practice2025-02-18T17:42:06ZMyocardial perfusion cardiovascular magnetic resonance (pCMR) using first-pass contrast-enhanced imaging could play an important role in the detection of epicardial and microvascular coronary artery disease. Recently, the emergence of quantitative pCMR has provided a more reliable and observer-independent analysis compared to visual interpretation of dynamic images. This review aims to cover the basics of quantitative pCMR, from acquisition protocols, its use in preclinical and clinical studies, image reconstruction and motion handling, to automated quantitative pCMR pipelines. It also offers an overview of emerging tools in the field, including artificial intelligence-based methods.2025-02-18T17:42:06ZAll copyright for this preprint belongs to the authors. The work is protected under copyright and may not be reproduced, distributed, or used without proper citation and permission, unless otherwise specifiedCatarina N CarvalhoAndreia GasparCarlos RealCarlos Galán-ArriolaElisa Moya-SáezRosa-María Menchón-LaraJavier SanchezCarlos Alberola-LópezRita G NunesBorja IbáñezTeresa M Correiahttp://arxiv.org/abs/2502.12349v1Quantitative diagnosis of amyloid without Congo red staining using polarized light microscopy2025-02-17T22:31:02ZAmyloidosis is a protein misfolding disease caused by the deposition of large, insoluble aggregates (amyloid fibrils) of protein in a tissue, which has been associated with various conditions, such as lymphoid disorders, Alzheimer's disease, diabetes mellitus type 2, chronic inflammatory processes, and cancers. Amyloid fibrils are commonly diagnosed by qualitative observation of green birefringence from Congo red stained biopsy tissue samples under polarized light, a technique that is limited by lack of specificity, dependence on subjective interpretation, and technical constraints. Studies emphasize the utility of quantitative polarized light microscopy (PLM) methodology to diagnose amyloid fibrils in Congo red stained tissues. However, while Congo red enhances the intrinsic birefringence of amyloid fibrillar structures, there are significant disadvantages such as the appearance of multiple non-green colors under polarized light and binding to other structures, which may result in misdiagnoses with Congo red dye and inconclusive explanations. In this work, we present an improved PLM methodology for quantitative detection of amyloid fibrils without requiring Congo red staining. We perform PLM measurements on four tissues: abdominal subcutaneous tissue biopsy, duodenal biopsy, thyroid biopsy, and breast biopsy, both with Congo red stain and H\&E stain, and through Fourier analysis quantify birefringence, birefringent axis orientation, dichroism, optical activity, and relative amyloid density. These results emphasize a quantitative analysis for amyloid diagnosis rooted in Fourier signal harmonics that does not require Congo red dye and paves the way for rapid, simple, and accurate diagnosis of amyloid fibrils.2025-02-17T22:31:02ZOwen LaileyMaria Agustina AlaisLiuhe WangPinki ChahalDavid G. CoryTimothy KhooEkaterina Olkhov-MitselDusan SarenacDmitry A. PushinJelena Mirkovichttp://arxiv.org/abs/2406.00122v4$\textit{In vivo}$ fundus imaging and computational refocusing with a diffuser-based fundus camera2025-02-17T22:03:02ZSignificance: Access to diagnostic eye care could be expanded with high-throughput and easy-to-use tools. Phase mask-based imaging may improve the fundus camera by enabling computational refocusing with no moving parts. While phase mask-based imaging has been demonstrated in a model eye, this approach has not been shown $\textit{in vivo}$.
Aim: A computational fundus camera was designed, constructed, and evaluated with the goal of determining the feasibility and performance of phase mask-based computational imaging of the $\textit{in vivo}$ fundus.
Approach: A holographic diffuser was introduced in a modified commercial fundus camera at a plane conjugate to the ocular pupil, resulting in a linear and shift-invariant point spread function that varies with refractive error. The image could be digitally refocused across a range of $\geq\pm$ 10 diopters of defocus error. The device was tested for ocular safety, and a human imaging pilot study was performed.
Results: The device captured and digitally refocused color human fundus images. The field of view was $\geq$35 degrees and resolution was 7.7-9.6 line pairs per mm.
Conclusions: We present the first $\textit{in vivo}$ diffuser-based fundus images, demonstrating the feasibility of computational imaging for ocular diagnostics.2024-05-31T18:23:11ZCorey SimmererMarisa MorakisLei TianLia Gomez-PerezT. Y. Alvin LiuNicholas J. Durrhttp://arxiv.org/abs/2502.11991v1Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes2025-02-17T16:32:10ZThis study evaluates the uncertainty in nanodosimetric calculations caused by variations in interaction cross sections within Monte Carlo Track Structure (MCTS) simulation codes. Nanodosimetry relies on accurately simulating particle interactions at the molecular scale. Different MCTS codes employ distinct physical models and datasets for electron interactions in liquid water, a surrogate for biological tissues. The paper focuses on the Ionization Cluster Size Distribution (ICSD) generated by electrons of varying energies in nanometric volumes. Seven MCTS codes were tested using their native cross sections and a common dataset derived from averaging data used in the participating codes. The results reveal significant discrepancies among the codes in ICSDs and derived biologically relevant nanodosimetric quantities such as mean ionization numbers (M1) and probabilities of obtaining two or more ionizations (F2). The largest variations were observed for low-energy electrons, where the contribution from interaction cross sections dominates the overall uncertainties. For instance, M1 values for ICSDs of electron of 20 eV can differ by around 45 % (RSD) and 34 % (RSD) was found for F2 values of ICSDs of electrons of 50 eV. Using common cross sections substantially reduced the discrepancies, suggesting that cross section datasets are the primary source of variability. Finally, estimates of deoxyribonucleic acid (DNA) damage using the PARTRAC code highlight tht cross section variations have a non-negligible impact simulated biological outcomes, particularly for double-strand breaks (DSBs) Indeed, despite the fact that many other parameters in the simulation that can greatly differ from one code to another, the different interaction cross-sections studied in this work can lead to differences in the number of DSBs calculated with the PARTRAC code of up to 15%.2025-02-17T16:32:10Z39 pages, 8 figures, 14 tables; submitted to PLOS OnePLOS One 21, e0340500 (2026)Carmen VillagrasaGiorgio BaioccoZine-El-Abidine ChaouiMichael DingfelderSébastien IncertiPavel KundrátIoanna KyriakouYusuke MatsuyaTakeshi KaiAlessio ParisYann PerrotMarcin PietrzakJan SchuemannHans Rabus10.1371/journal.pone.0340500