https://arxiv.org/api/CNRrKm0gqqRGP5VX58zltqvUffk 2026-06-28T22:14:34Z 9008 1545 15 http://arxiv.org/abs/2502.21129v1 Microscopic Propagator Imaging (MPI) with Diffusion MRI 2025-02-28T15:10:00Z We propose Microscopic Propagator Imaging (MPI) as a novel method to retrieve the indices of the microscopic propagator which is the probability density function of water displacements due to diffusion within the nervous tissue microstructures. Unlike the Ensemble Average Propagator indices or the Diffusion Tensor Imaging metrics, MPI indices are independent from the mesoscopic organization of the tissue such as the presence of multiple axonal bundle directions and orientation dispersion. As a consequence, MPI indices are more specific to the volumes, sizes, and types of microstructures, like axons and cells, that are present in the tissue. Thus, changes in MPI indices can be more directly linked to alterations in the presence and integrity of microstructures themselves. The methodology behind MPI is rooted on zonal modeling of spherical harmonics, signal simulation, and machine learning regression, and is demonstrated on both synthetic and Human Diffusion MRI data. 2025-02-28T15:10:00Z Tommaso Zajac Gloria Menegaz Marco Pizzolato http://arxiv.org/abs/2410.00669v3 Development of the normalization method for the first large field-of-view plastic-based PET Modular scanner 2025-02-28T05:10:13Z In positron emission tomography acquisition (PET), sensitivity along a line of response can vary due to crystal geometrical arrangements in the scanner and/or detector inefficiencies, leading to severe artefacts in the reconstructed image. To mitigate these effects, data must be corrected by a set of normalization coefficients applied to each line of response. The J-PET Modular scanner is a PET device made of 50 cm long plastic strips arranged axially, currently in operation at the Jagiellonian University in Kraków (Poland). We have implemented a normalization method for the large field-of-view plastic-based J-PET Modular scanner using the component-based approach. We estimated the geometric normalization factors for the J-PET Modular scanner using Monte Carlo simulations. We also analysed the effects of variations in detection efficiency. A dedicated cylindrical phantom was simulated to investigate the impact of various factors on image quality. The image quality was quantified in terms of radial and axial uniformity metrics, and the standard deviation to mean intensity ratio, determined for a set of image slices. Without normalization, reconstructions of a uniform cylinder exhibit artefacts. These artefacts were satisfactorily compensated using the normalization factors. Applying geometrical corrections lowers the non-uniformity of the image expressed as a standard deviation-to-mean ratio to a range between 5.5 % to 8.5 %. Computationally, the technique is straightforward to parallelize, making it time-efficient. Preliminary estimates suggest that the method is appropriate for use with long axial field-of-view scanners, such as the total-body J-PET, currently under development at the Jagiellonian University. 2024-10-01T13:28:38Z This paper was decided to be withdrawn due to failure to resolve collaborative disputes within the research team or authorship issues. This status might change in the future A. Coussat W. Krzemien J. Baran K. Dulski K. Klimaszewski R. Y. Shopa L. Raczyński W. Wiślicki http://arxiv.org/abs/2502.01988v2 ReMiDi: Reconstruction of Microstructure Using a Differentiable Diffusion MRI Simulator 2025-02-28T00:29:07Z We propose ReMiDi, a novel method for inferring neuronal microstructure as arbitrary 3D meshes using a differentiable diffusion Magnetic Resonance Imaging (dMRI) simulator. We first implemented in PyTorch a differentiable dMRI simulator that simulates the forward diffusion process using a finite-element method on an input 3D microstructure mesh. To achieve significantly faster simulations, we solve the differential equation semi-analytically using a matrix formalism approach. Given a reference dMRI signal $S_{ref}$, we use the differentiable simulator to iteratively update the input mesh such that it matches $S_{ref}$ using gradient-based learning. Since directly optimizing the 3D coordinates of the vertices is challenging, particularly due to ill-posedness of the inverse problem, we instead optimize a lower-dimensional latent space representation of the mesh. The mesh is first encoded into spectral coefficients, which are further encoded into a latent $\textbf{z}$ using an auto-encoder, and are then decoded back into the true mesh. We present an end-to-end differentiable pipeline that simulates signals that can be tuned to match a reference signal by iteratively updating the latent representation $\textbf{z}$. We demonstrate the ability to reconstruct microstructures of arbitrary shapes represented by finite-element meshes, with a focus on axonal geometries found in the brain white matter, including bending, fanning and beading fibers. Our source code is available online. 2025-02-04T04:03:08Z 15 pages, ~13 figures, 2 algorithms, 1 table Prathamesh Pradeep Khole Zahra Kais Petiwala Shri Prathaa Magesh Ehsan Mirafzali Utkarsh Gupta Jing-Rebecca Li Andrada Ianus Razvan Marinescu http://arxiv.org/abs/2502.20351v1 KNOWM Memristors in a Bridge Synapse delay-based Reservoir Computing system for detection of epileptic seizures 2025-02-27T18:23:24Z Nanodevices that show the potential for non-linear transformation of electrical signals and various forms of memory can be successfully used in new computational paradigms, such as neuromorphic or reservoir computing (RC). Dedicated hardware implementations based on functional neuromorphic structures significantly reduce energy consumption and/or increase computational capabilities of a given artificial neural network system. Concepts of RC, which as a flexible computational paradigm can be highly inclusive, are often used as a model to describe computations performed in materia. With mostly fixed internal structure, solid-state devices, especially memristors, are studied as computational substrates in various RC systems. In this work, we present single-node Echo State Machine (SNESM) RC system based on bridge synapse as a computational substrate (consisting of 4 memristors and a differential amplifier) used for epileptic seizure detection. KNOWM memristors were posed as ideal candidates because of their easy prototyping and reliability of operation. In this account, we present an application of commercially available KNOWM memristors in various neuromorphic applications, from simple analysis of switching and internal dynamics (elucidated form noise spectroscopy and total harmonic distortion analysis) to the classification and recognition of complex time series: epilepsy seizure recognition using a wrist-worn triaxial accelerometer. 2025-02-27T18:23:24Z International Journal of Parallel, Emergent and Distributed Systems, 2022, 37(5), 512-527 Dawid Przyczyna Grzegorz Hess Konrad Szaciłowski 10.1080/17445760.2022.2088751 http://arxiv.org/abs/2403.16722v3 A Monte Carlo simulation framework for investigating the effect of inter-track coupling on H$_2$O$_2$ productions at ultra-high dose rates 2025-02-27T12:59:19Z Background: Lower production of H$_2$O$_2$ in water is a hallmark of ultra-high dose rate (UHDR) compared to the conventional dose rate (CDR). However, the current computational models based on the predicted yield of H$_2$O$_2$ are in opposite of the experimental data. Methods: We construct an analytical model for the rate equation in the production of H$_2$O$_2$ from \ce{^{.}OH}-radicals and use it as a guide to propose a hypothetical geometrical inhomogeneity in the configuration of particles in the FLASH-UHDR beams. We perform a series of Monte Carlo (MC) simulations of the track structures for a system of charged particles impinging the medium in the form of clusters and/or bunches. Results: We demonstrate the interplay of diffusion, reaction rates, and overlaps in track-spacing attribute to a lower yield of H$_2$O$_2$ at FLASH-UHDR vs. CDR. This trend is reversed if spacing among the tracks becomes larger than a critical value, with a length scale that is proportional to the diffusion length of \ce{^{.}OH}-radicals modulated by a rate of decay due to recombination with other species, available within a track, and the space among the tracks. The latter is substantial on the suppressing of the H$_2$O$_2$ population at FLASH-UHDR relative to CDR. Conclusions: Based on our analysis of the present work, at FLASH-UHDR, the lower yield in H$_2$O$_2$ can be interpreted as a signature of bunching the particles in beams of ionizing radiation. The beams enter the medium in closely packed clusters and form inhomogeneities in the track-structure distribution. Thus the MC simulations based on the assumption of uniformly distributed tracks are unable to explain the experimental data. 2024-03-25T12:57:41Z Ramin Abolfath Sedigheh Fardirad Houda Kacem Marie-Catherine Vozenin Abbas Ghasemizad http://arxiv.org/abs/2502.19780v1 Visualising Ventilation Changes following Endobronchial Valve Placement with X-ray Velocimetry Functional Lung Imaging 2025-02-27T05:45:46Z Objective: Endobronchial Valves are a minimally invasive treatment for emphysema. After bronchoscopic placement the valves reduce the flow of air into targeted areas of the lung, causing collapse, and allowing the remainder of the lung to function more effectively. Approach: X-ray Velocimetry is a novel method that uses X-ray images taken during a breath to track lung motion, producing 3D maps of local ventilation. Healthy sheep received a CT scan and underwent X-ray Velocimetry imaging before and after endobronchial valves were placed in the lung. Sheep were imaged again when the endobronchial valves were removed after 14 days. Main results: X-ray Velocimetry enabled visualisation and quantification of a reduction of airflow to the areas downstream of the endobronchial valves, both in areas where collapse was and was not visible in CT. Changes to ventilation were also clearly visible in the remainder of the lungs. Significance: This preclinical study has shown X-ray Velocimetry is capable of detecting changes to ventilation caused by endobronchial valve placement, paving the way towards use in patients. 2025-02-27T05:45:46Z Ronan Smith Charlotte Thomas Phan Nguyen Arash Badiei Nina Eikelis Kristopher Nilsen Piraveen Pirakalathanan David Parsons Martin Donnelley http://arxiv.org/abs/2502.19650v1 Investigation of Non-Radiative Relaxation Dynamics Under Pulsed Excitation Using Photon Absorption Remote Sensing: A Proof-of-Principle Study in Mechanical Sensing 2025-02-27T00:45:43Z The mechanical properties of micro-scale bio-entities are fundamental for understanding their functions and pathological states. However, current methods for assessing elastic properties at single-particle level such as Brillouin and atomic force microscopies exhibit intrinsic limitations, including being often slow, having poor resolution, or involving complicated and invasive setups. In this study, we explore Photon Absorption Remote Sensing (PARS) microscopy as a unique solution for mechanical sensing of single micro-objects. PARS uses probe beam scattering/reflectivity measurements to capture non-radiative relaxation process following the absorption of a pulse of light by a micro-object. In particular, we demonstrate that, when operating at GHz-range bandwidth, PARS can trace the sub-nanosecond dynamics of non-radiative relaxation in individual micro-objects, capturing both photoacoustic (PA) pressure propagation and thermal diffusion. This GHz-range measurement, in conjunction with a developed descriptive model, enables the experimental extraction of a minimally distorted PA temporal profile. The PA temporal profile contain information on the ratio between the absorbing object's sound speed and its characteristic diameter, offering a new dimension in PARS microscopy. This enables the assessment of the object's elastic properties, deduced from its speed of sound. Additionally, it offers the potential for sizing objects with known sound speeds. The proof of principle experiments was conducted using spherical polystyrene absorbers, ranging in size from 1 to 10 micrometers with known properties, embedded in a Polydimethylsiloxane (PDMS) matrix. This technique expands the scope of PARS imaging, opening new perspectives for clinical applications in mechanobiology by demonstrating its potential for mechanical imaging. 2025-02-27T00:45:43Z Channprit Kaur Aria Hajiahmadi Benjamin R. Ecclestone James E. D. Tweel James A. Tummon Simmons Parsin Haji Reza http://arxiv.org/abs/2502.18829v1 Bridging Spectroscopy and Advanced Molecular Orientation Analysis with New 4+ Angle Polarization Toolbox in Quasar 2025-02-26T05:04:39Z Anisotropy plays a critical role in governing the mechanical, thermal, electrical, magnetic, and optical properties of materials, influencing their behavior across diverse applications. Probing and quantifying this directional dependence is crucial for advancing materials science and biomedical research, as it provides a deeper understanding of structural orientations at the molecular level, encompassing both scientific and industrial benefits. This study introduces the "4+ Angle Polarization" widget, an innovative extension to the open-source Quasar platform (https://quasar.codes/), tailored for advanced multiple-angle polarization analysis. This toolbox enables precise molecular orientation analysis of complex microspectroscopic datasets through a streamlined workflow. Using polarized Fourier transform infrared (p-FTIR) spectroscopy, we demonstrate its versatility across various sample types, including polylactic acid (PLA) organic crystals, murine cortical bone, and human osteons. By overcoming the limitations of traditional two-angle methods, the widget significantly enhances the accuracy of structural and orientational analysis. This novel analytical tool expands the potential of multiple-angle p-FTIR techniques into advanced characterization of structural anisotropy in heterogeneous systems, providing transformative insights for materials characterization, biomedical imaging and beyond. 2025-02-26T05:04:39Z 20 pages, 9 figures Callum Gassner Jitraporn Vongsvivut Meguya Ryu Soon Hock Ng Marko Toplak Vijayakumar Anand Pooja Takkalkar Mary Louise Fac Natalie A. Sims Bayden R. Wood Mark J. Tobin Saulius Juodkazis Junko Morikawa http://arxiv.org/abs/2408.13945v2 Personalized Topology-Informed Localization of Standard 12-Lead ECG Electrode Placement from Incomplete Cardiac MRIs for Efficient Cardiac Digital Twins 2025-02-25T14:57:06Z Cardiac digital twins (CDTs) offer personalized in-silico cardiac representations for the inference of multi-scale properties tied to cardiac mechanisms. The creation of CDTs requires precise information about the electrode position on the torso, especially for the personalized electrocardiogram (ECG) calibration. However, current studies commonly rely on additional acquisition of torso imaging and manual/semi-automatic methods for ECG electrode localization. In this study, we propose a novel and efficient topology-informed model to fully automatically extract personalized ECG standard electrode locations from 2D clinically standard cardiac MRIs. Specifically, we obtain the sparse torso contours from the cardiac MRIs and then localize the standard electrodes of 12-lead ECG from the contours. Cardiac MRIs aim at imaging of the heart instead of the torso, leading to incomplete torso geometry within the imaging. To tackle the missing topology, we incorporate the electrodes as a subset of the keypoints, which can be explicitly aligned with the 3D torso topology. The experimental results demonstrate that the proposed model outperforms the time-consuming conventional model projection-based method in terms of accuracy (Euclidean distance: $1.24 \pm 0.293$ cm vs. $1.48 \pm 0.362$ cm) and efficiency ($2$~s vs. $30$-$35$~min). We further demonstrate the effectiveness of using the detected electrodes for in-silico ECG simulation, highlighting their potential for creating accurate and efficient CDT models. The code is available at https://github.com/lileitech/12lead_ECG_electrode_localizer. 2024-08-25T21:49:10Z Lei Li Hannah Smith Yilin Lyu Julia Camps Shuang Qian Blanca Rodriguez Abhirup Banerjee Vicente Grau http://arxiv.org/abs/2502.17609v1 SynthRAD2025 Grand Challenge dataset: generating synthetic CTs for radiotherapy 2025-02-24T19:53:09Z Medical imaging is essential in modern radiotherapy, supporting diagnosis, treatment planning, and monitoring. Synthetic imaging, particularly synthetic computed tomography (sCT), is gaining traction in radiotherapy. The SynthRAD2025 dataset and Grand Challenge promote advancements in sCT generation by providing a benchmarking platform for algorithms using cone-beam CT (CBCT) and magnetic resonance imaging (MRI). The dataset includes 2362 cases: 890 MRI-CT and 1472 CBCT-CT pairs from head-and-neck, thoracic, and abdominal cancer patients treated at five European university medical centers (UMC Groningen, UMC Utrecht, Radboud UMC, LMU University Hospital Munich, and University Hospital of Cologne). Data were acquired with diverse scanners and protocols. Pre-processing, including rigid and deformable image registration, ensures high-quality, modality-aligned images. Extensive quality assurance validates image consistency and usability. All imaging data is provided in MetaImage (.mha) format, ensuring compatibility with medical image processing tools. Metadata, including acquisition parameters and registration details, is available in structured CSV files. To maintain dataset integrity, SynthRAD2025 is divided into training (65%), validation (10%), and test (25%) sets. The dataset is accessible at https://doi.org/10.5281/zenodo.14918089 under the SynthRAD2025 collection. This dataset supports benchmarking and the development of synthetic imaging techniques for radiotherapy applications. Use cases include sCT generation for MRI-only and MR-guided photon/proton therapy, CBCT-based dose calculations, and adaptive radiotherapy workflows. By integrating diverse acquisition settings, SynthRAD2025 fosters robust, generalizable image synthesis algorithms, advancing personalized cancer care and adaptive radiotherapy. 2025-02-24T19:53:09Z 22 pages, 8 tables, 4 figures; Under submission to Medical Physics, as dataset paper for the SynhtRAD2025 Grand Challenge https://synthrad2025.grand-challenge.org/ Adrian Thummerer Erik van der Bijl Arthur Jr Galapon Florian Kamp Mark Savenije Christina Muijs Shafak Aluwini Roel J. H. M. Steenbakkers Stephanie Beuel Martijn P. W. Intven Johannes A. Langendijk Stefan Both Stefanie Corradini Viktor Rogowski Maarten Terpstra Niklas Wahl Christopher Kurz Guillaume Landry Matteo Maspero 10.1002/mp.17981 http://arxiv.org/abs/2502.17209v1 Motion-Robust T2* Quantification from Gradient Echo MRI with Physics-Informed Deep Learning 2025-02-24T14:41:53Z Purpose: T2* quantification from gradient echo magnetic resonance imaging is particularly affected by subject motion due to the high sensitivity to magnetic field inhomogeneities, which are influenced by motion and might cause signal loss. Thus, motion correction is crucial to obtain high-quality T2* maps. Methods: We extend our previously introduced learning-based physics-informed motion correction method, PHIMO, by utilizing acquisition knowledge to enhance the reconstruction performance for challenging motion patterns and increase PHIMO's robustness to varying strengths of magnetic field inhomogeneities across the brain. We perform comprehensive evaluations regarding motion detection accuracy and image quality for data with simulated and real motion. Results: Our extended version of PHIMO outperforms the learning-based baseline methods both qualitatively and quantitatively with respect to line detection and image quality. Moreover, PHIMO performs on-par with a conventional state-of-the-art motion correction method for T2* quantification from gradient echo MRI, which relies on redundant data acquisition. Conclusion: PHIMO's competitive motion correction performance, combined with a reduction in acquisition time by over 40% compared to the state-of-the-art method, make it a promising solution for motion-robust T2* quantification in research settings and clinical routine. 2025-02-24T14:41:53Z Under Review Hannah Eichhorn Veronika Spieker Kerstin Hammernik Elisa Saks Lina Felsner Kilian Weiss Christine Preibisch Julia A. Schnabel 10.1002/mrm.70050 http://arxiv.org/abs/2502.16326v1 A mixed integer programming approach to minibeam aperture optimization for multi-collimator proton minibeam radiotherapy 2025-02-22T19:03:25Z Background: Multi-collimator proton minibeam radiation therapy (MC-pMBRT) has recently emerged as a versatile technique for dose shaping, enabling peak-valley dose patterns in organs-at-risk (OAR) while maintaining a uniform dose distribution in tumor. MC-pMBRT leverages a set of generic multi-slit collimators (MSC) with varying center-to-center distances. However, the current method for minibeam aperture optimization (MAO), i.e., the selection of MSC per beam angle, is manual and heuristic, resulting in computational inefficiencies and no guarantee of optimality. This work introduces a novel mixed integer programming (MIP) approach to MAO for optimizing MC-pMBRT plan quality. Methods: The proposed MIP approach jointly optimizes dose distributions, peak-to-valley dose ratio (PVDR), and selects the optimal set of MSC per beam angle. The optimization problem includes decision variables for MSC selection per beam angle and spot weights. The proposed MIP approach is a two-step process: Step1: the binary variables are optimally determined to select MSC for each beam angle; Step 2: the continuous variables are solved to determine the spot weights. Both steps utilize iterative convex relaxation and the alternating direction method of multipliers to solve the problems. Results: The proposed MIP method for MAO (MIP-MAO) was validated against the conventional heuristic method (CONV) for MC-pMBRT treatment planning. Results indicate that MIP-MAO enhances the conformity index (CI) for the target and improves PVDR for OAR. For instance, in a head-and-neck case, CI improved from 0.61 (CONV) to 0.70 (MIP-MAO); in an abdomen case, CI improved from 0.78 (CONV) to 0.83 (MIP-MAO). Additionally, MIP-MAO reduced mean doses in the body and OAR. Conclusions: A novel MIP approach for MAO in MC-pMBRT is presented, showing demonstrated improvements in plan quality and PVDR compared to the heuristic method. 2025-02-22T19:03:25Z Nimita Shinde Weijie Zhang Yuting Lin Hao Gao http://arxiv.org/abs/2502.16269v1 Quasi Crystal based Circular Patch Antenna with Artificial Magnetic Conductor for Breast Cancer Detection 2025-02-22T15:47:51Z Design and simulation of Quasi Crystal based Artificial Magnetic Conductor (AMC) Circular Microstrip Patch Antenna for tumor detection is discussed. Initially, a Circular Microstrip patch antenna is designed with a resonant frequency of $2.45 \, \text{GHz}$. The performance of the designed antenna can be improved by incorporating AMC in order to avoid surface waves. In this paper, we propose a novel technique for detecting malignant tissues in a more focusing manner using a Penrose patterned Quasi crystal. Quasi crystals act as a focusing device as it can transmit electromagnetic waves in a narrow direction. The tumor of size $3 \, \text{mm}$ is placed at a particular location specifically at $(0,0,10)$ in the breast phantom model. Our aim is the proposed model could identify the exact tumor location or the nearest co-ordinates of the actual location. Scattering parameters $S_{11}$ and $S_{22}$ obtained at $-10.30 \, \text{dB}$ and $-9.15 \, \text{dB}$ respectively at the tumor location $(0,-4,30)$ without the presence of Quasi crystal. Results were compared in each stage with and without Penrose Quasi crystal based patch antenna. The Quasi crystal based model was simulated and the results $S_{11}$ and $S_{22}$ parameters got improved at $-10.02 \, \text{dB}$ and $-9.37 \, \text{dB}$ respectively at the tumor location $(-1, -1, 13)$. The total specific absorption rate (SAR) of the proposed model is $0.139 \, \text{W/kg}$. Hence the proposed model is highly bio-compatible and safely applicable for human body. 2025-02-22T15:47:51Z 14 pages, 15 figures, 4 tables, submitted to International Conference on Magnetic materials and Applications, ICMAGMA-2023 Vishnupriya Leena Nikhil Kumar http://arxiv.org/abs/2502.14524v2 Accelerated X-Ray Fluorescence Computed Tomography via Multi-Pencil-Beam Excitation 2025-02-21T19:45:43Z X-ray fluorescence computed tomography (XFCT), a form of X-ray molecular imaging, offers detailed quantitative imaging capabilities for high-Z metal nanoparticles (MNPs), which are widely studied for their applications in multifunctional theranostics. Due to its affordability and accessibility, the benchtop XFCT prototype typically employs a single-pixel detector (SPD) with single-pencil-beam (SPB) X-ray excitation. While this design (resembling the first-generation CT geometry) achieves reliable detection sensitivity, it is hindered by long imaging times. The use of simultaneous multiple-pencil-beam (MPB) excitation presents a promising solution to significantly reduce imaging times. In this study, we developed a repeatable workflow that combines Monte Carlo (MC) simulations and 3D printing to design Nbeam-MPB collimator, where Nbeam is the number of beams generated by the collimator. As an initial test, we fabricated a 2-MPB collimator and evaluated the performance of 2-MPB-based XFCT imaging on a physical phantom and small animals surgically implanted with agarose pellets containing gold chloride (H[AuCl4]). The results demonstrated a 2x acceleration in image acquisition without compromising the contrast-to-noise ratio (CNR). We further investigated the concept of Nbeam-MPB acceleration on the MC computational XFCT system, which confirmed the feasibility of achieving at least 4x acceleration with 4-MPB excitation. Combined with additional system optimization, such as X-ray beam flux optimization, XFCT imaging could be further accelerated, reducing acquisition time from hours to minutes and meeting the requirements for routine MNP imaging. 2025-02-20T12:59:16Z Ryder M. Schmidt Daiki Hara Jorge D. Vega Marwan Abuhaija Brett Bocian Wendi Ma Nesrin Dogan Alan Pollack Ge Wang John C. Ford Junwei Shi http://arxiv.org/abs/2502.15185v1 Key Body Posture Characteristics of Short-distance Speed Skaters at the Start Based on Artificial Intelligence 2025-02-21T03:36:17Z Objective To conduct biomechanical analysis on the starting technique of male short-distance speed skating athletes in China and determine the key factors affecting the effectiveness of the starting movement. Methods 13 high-level male short-distance speed skating athletes were selected as the test subjects, and kinematic data were collected using an artificial intelligence video capture and analysis system. The body posture features and their effects on the starting movement performance were analyzed in the three stages of starting preparation, starting, and sprinting. Results The post-stability angle, anterior knee angle of the front leg, posterior knee angle of the rear leg, and stride length showed moderate to high positive correlations with the starting speed during the starting preparation stage. The trunk angle showed a high negative correlation with the starting speed. The trunk angle (TO4, TD4, TO6, TD6), hip angle (TO1, TO4, TO6), and knee angle (TD1) showed moderate to high negative correlations with the effectiveness of the starting movement during the starting and sprinting stages. The knee angle (TD2), ice-contact angle (TD2, TD4, TD5, TD6), and propulsion angle (TO1, TO4, TO7) showed moderate positive correlations with the effectiveness of the starting movement. Conclusion Stride length, left knee angle, and post-stability angle are the key factors affecting the starting speed. The larger the post-stability angle and left knee angle and the longer the stride length, the faster the starting speed. During the starting and sprinting stages, the smaller the ice-contact angle and propulsion angle, the greater the trunk angle and hip angle changes, the more effective the starting movement. 2025-02-21T03:36:17Z Zhang Xueliana Fang Yingjieb Liu Hang