https://arxiv.org/api/HGvepC/AXRrhAfku/88Zdsuad182026-06-27T19:02:13Z9008153015http://arxiv.org/abs/2503.03770v1Fusion of Various Optimization Based Feature Smoothing Methods for Wearable and Non-invasive Blood Glucose Estimation2025-03-06T16:42:53ZRecently, the wearable and non-invasive blood glucose estimation approach has been proposed. However, due to the unreliability of the acquisition device, the presence of the noise and the variations of the acquisition environments, the obtained features and the reference blood glucose values are highly unreliable. To address this issue, this paper proposes a polynomial fitting approach to smooth the obtained features or the reference blood glucose values. First, the blood glucose values are estimated based on the individual optimization approaches. Second, the absolute difference values between the estimated blood glucose values and the actual blood glucose values based on each optimization approach are computed. Third, these absolute difference values for each optimization approach are sorted in the ascending order. Fourth, for each sorted blood glucose value, the optimization method corresponding to the minimum absolute difference value is selected. Fifth, the accumulate probability of each selected optimization method is computed. If the accumulate probability of any selected optimization method at a point is greater than a threshold value, then the accumulate probabilities of these three selected optimization methods at that point are reset to zero. A range of the sorted blood glucose values are defined as that with the corresponding boundaries points being the previous reset point and this reset point. Hence, after performing the above procedures for all the sorted reference blood glucose values in the validation set, the regions of the sorted reference blood glucose values and the corresponding optimization methods in these regions are determined. The computer numerical simulation results show that our proposed method yields the mean absolute relative deviation (MARD) at 0.0930 and the percentage of the test data falling in the zone A of the Clarke error grid at 94.1176%.2025-03-06T16:42:53ZThis version corrects several typosIET Systems Biology, 2023, 17(3): 107-120Yiting WeiGuangdong University of Technology, Guangzhou, ChinaBingo Wing-Kuen LingGuangdong University of Technology, Guangzhou, ChinaDanni ChenGuangdong University of Technology, Guangzhou, ChinaYuheng DaiGuangdong University of Technology, Guangzhou, ChinaQing LiuGuangdong University of Technology, Guangzhou, China10.1049/syb2.12063http://arxiv.org/abs/2503.04469v1An artificially intelligent magnetic resonance spectroscopy quantification method: Comparison between QNet and LCModel on the cloud computing platform CloudBrain-MRS2025-03-06T14:19:55ZObjctives: This work aimed to statistically compare the metabolite quantification of human brain magnetic resonance spectroscopy (MRS) between the deep learning method QNet and the classical method LCModel through an easy-to-use intelligent cloud computing platform CloudBrain-MRS. Materials and Methods: In this retrospective study, two 3 T MRI scanners Philips Ingenia and Achieva collected 61 and 46 in vivo 1H magnetic resonance (MR) spectra of healthy participants, respectively, from the brain region of pregenual anterior cingulate cortex from September to October 2021. The analyses of Bland-Altman, Pearson correlation and reasonability were performed to assess the degree of agreement, linear correlation and reasonability between the two quantification methods. Results: Fifteen healthy volunteers (12 females and 3 males, age range: 21-35 years, mean age/standard deviation = 27.4/3.9 years) were recruited. The analyses of Bland-Altman, Pearson correlation and reasonability showed high to good consistency and very strong to moderate correlation between the two methods for quantification of total N-acetylaspartate (tNAA), total choline (tCho), and inositol (Ins) (relative half interval of limits of agreement = 3.04%, 9.3%, and 18.5%, respectively; Pearson correlation coefficient r = 0.775, 0.927, and 0.469, respectively). In addition, quantification results of QNet are more likely to be closer to the previous reported average values than those of LCModel. Conclusion: There were high or good degrees of consistency between the quantification results of QNet and LCModel for tNAA, tCho, and Ins, and QNet generally has more reasonable quantification than LCModel.2025-03-06T14:19:55ZMeijin LinLin GuoDicheng ChenJianshu ChenZhangren TuXu HuangJianhua WangJi QiYuan LongZhiguo HuangDi GuoXiaobo QuHaiwei Hanhttp://arxiv.org/abs/2503.04453v1Reproducibility Assessment of Magnetic Resonance Spectroscopy of Pregenual Anterior Cingulate Cortex across Sessions and Vendors via the Cloud Computing Platform CloudBrain-MRS2025-03-06T14:06:50ZGiven the need to elucidate the mechanisms underlying illnesses and their treatment, as well as the lack of harmonization of acquisition and post-processing protocols among different magnetic resonance system vendors, this work is to determine if metabolite concentrations obtained from different sessions, machine models and even different vendors of 3 T scanners can be highly reproducible and be pooled for diagnostic analysis, which is very valuable for the research of rare diseases. Participants underwent magnetic resonance imaging (MRI) scanning once on two separate days within one week (one session per day, each session including two proton magnetic resonance spectroscopy (1H-MRS) scans with no more than a 5-minute interval between scans (no off-bed activity)) on each machine. were analyzed for reliability of within- and between- sessions using the coefficient of variation (CV) and intraclass correlation coefficient (ICC), and for reproducibility of across the machines using correlation coefficient. As for within- and between- session, all CV values for a group of all the first or second scans of a session, or for a session were almost below 20%, and most of the ICCs for metabolites range from moderate (0.4-0.59) to excellent (0.75-1), indicating high data reliability. When it comes to the reproducibility across the three scanners, all Pearson correlation coefficients across the three machines approached 1 with most around 0.9, and majority demonstrated statistical significance (P<0.01). Additionally, the intra-vendor reproducibility was greater than the inter-vendor ones.2025-03-06T14:06:50ZRunhan ChenMeijin LinJianshu ChenLiangjie LinJiazheng WangXiaoqing LiJianhua WangXu HuangLing QianShaoxing LiuYuan LongDi GuoXiaobo QuHaiwei Hanhttp://arxiv.org/abs/2503.04380v1Non-Invasive Temporal Interference Electrical Stimulation for Spinal Cord Injury Rehabilitation: A Simulation Study2025-03-06T12:33:03ZBackground: Spinal cord injury (SCI) rehabilitation remains a major clinical challenge, with limited treatment options for functional recovery. Temporal interference (TI) electrical stimulation has emerged as a promising non-invasive neuromodulation technique capable of delivering deep and targeted stimulation. However, the application of TI stimulation in SCI rehabilitation remains largely unexplored. Methods: This study aims to investigate the feasibility of applying non-invasive TI electrical stimulation for SCI rehabilitation. Through computational modeling, we analyzed the electric field distribution characteristics in the spinal cord under different TI stimulation configurations. Based on these findings, we propose a clinically applicable TI stimulation protocol for SCI rehabilitation. Results: The results demonstrate that TI stimulation can effectively deliver focused electric fields to targeted spinal cord segments while maintaining non-invasiveness. The electric field intensity varied depending on individual anatomical differences, highlighting the need for personalized stimulation parameters. The proposed protocol provides a practical framework for applying TI stimulation in SCI rehabilitation and offers a non-invasive alternative to traditional spinal cord stimulation techniques. Conclusions: This study establishes the feasibility of using non-invasive TI stimulation for SCI rehabilitation. The proposed stimulation protocol enables precise and targeted spinal cord modulation. However, further research is needed to refine personalized stimulation parameters and validate the clinical efficacy of this approach.2025-03-06T12:33:03Z19 pages, 5 figuresXu XieYuchen XuHuilin MouXi LiLi ZhangZehao ShengWeidong ChenShaomin ZhangRuidong ChengMinmin Wanghttp://arxiv.org/abs/2503.03329v1Deep Learning-Based Diffusion MRI Tractography: Integrating Spatial and Anatomical Information2025-03-05T10:02:35ZDiffusion MRI tractography technique enables non-invasive visualization of the white matter pathways in the brain. It plays a crucial role in neuroscience and clinical fields by facilitating the study of brain connectivity and neurological disorders. However, the accuracy of reconstructed tractograms has been a longstanding challenge. Recently, deep learning methods have been applied to improve tractograms for better white matter coverage, but often comes at the expense of generating excessive false-positive connections. This is largely due to their reliance on local information to predict long range streamlines. To improve the accuracy of streamline propagation predictions, we introduce a novel deep learning framework that integrates image-domain spatial information and anatomical information along tracts, with the former extracted through convolutional layers and the later modeled via a Transformer-decoder. Additionally, we employ a weighted loss function to address fiber class imbalance encountered during training. We evaluate the proposed method on the simulated ISMRM 2015 Tractography Challenge dataset, achieving a valid streamline rate of 66.2%, white matter coverage of 63.8%, and successfully reconstructing 24 out of 25 bundles. Furthermore, on the multi-site Tractoinferno dataset, the proposed method demonstrates its ability to handle various diffusion MRI acquisition schemes, achieving a 5.7% increase in white matter coverage and a 4.1% decrease in overreach compared to RNN-based methods.2025-03-05T10:02:35ZYiqiong YangYitian YuanBaoxing RenYe WuYanqiu FengXinyuan Zhanghttp://arxiv.org/abs/2503.03277v1Fragmentation measurements with the FOOT experiment2025-03-05T09:00:04ZParticle Therapy (PT) has emerged as a powerful tool in cancer treatment, leveraging the unique dose distribution of charged particles to deliver high radiation levels to the tumor while minimizing damage to surrounding healthy tissue. Despite its advantages, further improvements in Treatment Planning Systems (TPS) are needed to address uncertainties related to fragmentation process, which can affect both dose deposition and effectiveness. These fragmentation effects also play a critical role in Radiation Protection in Space, where astronauts are exposed to high level of radiation, necessitating precise models for shielding optimization. The FOOT (FragmentatiOn Of Target) experiment addresses these challenges by measuring fragmentation cross-section with high precision, providing essential data for improving TPS for PT and space radiation protection strategies. This thesis contributes to the FOOT experiment in two key areas. First, it focuses on the performances of the vertex detector, which is responsible for reconstructing particle tracks and fragmentation vertexes with high spatial resolution. The study evaluates the detector's reconstruction algorithm and its efficiency to detect particles. Second the thesis present a preliminary calculation of fragmentation cross section, incorporating the vertex detector for the first time in these measurements.2025-03-05T09:00:04ZLuana Testahttp://arxiv.org/abs/2503.02788v1Reconstruction of proton relative stopping power with a granular calorimeter detector model2025-03-04T17:08:16ZProton computed tomography (pCT) aims to facilitate precise dose planning for hadron therapy, a promising and effective method for cancer treatment. Hadron therapy utilizes protons and heavy ions to deliver well focused doses of radiation, leveraging the Bragg peak phenomenon to target tumors while sparing healthy tissues. The Bergen pCT Collaboration aims to develop a novel pCT scanner, and accompanying reconstruction algorithms to overcome current limitations. This paper focuses on advancing the track- and image reconstruction algorithms, thereby enhancing the precision of the dose planning and reducing side effects of hadron therapy. A neural network aided track reconstruction method is presented.2025-03-04T17:08:16Z14 pages, 6 figures, 1 tableM. AehleJ. AlmeG. G. BarnaföldiG. BíróT. BodovaV. BorshchovA. van den BrinkM. ChaarB. DudásV. EikelandG. FeofilovC. GarthN. R. GaugerO. GrøttvikH. HelstrupS. IgolkinZs. JóleszR. KeidelC. KobdajT. KortusL. KuschV. LeonhardtS. MehendaleR. NingappaO. H. OdlandG. O'NeillG. PappT. PeitzmannH. E. S. PettersenP. PiersimoniM. ProtsenkoM. RauchA. Ur RehmanM. RichterD. RöhrichJ. SantanaA. SchillingJ. SecoA. SongmoolnakJ. Rambo SølieG. TambaveI. TymchukK. UllalandM. Varga-KőfaragóL. VolzB. WagnerS. WendzelA. WiebelR. XiaoS. YangH. YokoyamaS. Zillienhttp://arxiv.org/abs/2503.02485v1Calibration of the mechanical boundary conditions for a patient-specific thoracic aorta model including the heart motion effect2025-03-04T10:50:10ZObjective: we propose a procedure for calibrating 4 parameters governing the mechanical boundary conditions (BCs) of a thoracic aorta (TA) model derived from one patient with ascending aortic aneurysm. The BCs reproduce the visco-elastic structural support provided by the soft tissue and the spine and allow for the inclusion of the heart motion effect.
Methods: we first segment the TA from magnetic resonance imaging (MRI) angiography and derive the heart motion by tracking the aortic annulus from cine-MRI. A rigid-wall fluid-dynamic simulation is performed to derive the time-varying wall pressure field. We build the finite element model considering patient-specific material properties and imposing the derived pressure field and the motion at the annulus boundary. The calibration, which involves the zero-pressure state computation, is based on purely structural simulations. After obtaining the vessel boundaries from the cine-MRI sequences, an iterative procedure is performed to minimize the distance between them and the corresponding boundaries derived from the deformed structural model. A strongly-coupled fluid-structure interaction (FSI) analysis is finally performed with the tuned parameters and compared to the purely structural simulation.
Results and Conclusion: the calibration with structural simulations allows to reduce maximum and mean distances between image-derived and simulation-derived boundaries from 8.64 mm to 6.37 mm and from 2.24 mm to 1.83 mm, respectively. The maximum root mean square error between the deformed structural and FSI surface meshes is 0.19 mm. This procedure may prove crucial for increasing the model fidelity in replicating the real aortic root kinematics.2025-03-04T10:50:10ZVolume: 70 Issue: 11, November 2023, IEEE Transaction on Biomedical EngineeringLeonardo GeronziAline Bel-BrunonAntonio MartinezMichel RochetteMarco SensaleOlivier BouchotAlain LalandeSiyu LinPier Paolo ValentiniMarco Evangelos Biancolini10.1109/TBME.2023.3287680http://arxiv.org/abs/2503.02915v1Computer-aided shape features extraction and regression models for predicting the ascending aortic aneurysm growth rate2025-03-04T10:21:20ZObjective: ascending aortic aneurysm growth prediction is still challenging in clinics. In this study, we evaluate and compare the ability of local and global shape features to predict ascending aortic aneurysm growth.
Material and methods: 70 patients with aneurysm, for which two 3D acquisitions were available, are included. Following segmentation, three local shape features are computed: (1) the ratio between maximum diameter and length of the ascending aorta centerline, (2) the ratio between the length of external and internal lines on the ascending aorta and (3) the tortuosity of the ascending tract. By exploiting longitudinal data, the aneurysm growth rate is derived. Using radial basis function mesh morphing, iso-topological surface meshes are created. Statistical shape analysis is performed through unsupervised principal component analysis (PCA) and supervised partial least squares (PLS). Two types of global shape features are identified: three PCA-derived and three PLS-based shape modes. Three regression models are set for growth prediction: two based on gaussian support vector machine using local and PCA-derived global shape features; the third is a PLS linear regression model based on the related global shape features. The prediction results are assessed and the aortic shapes most prone to growth are identified.
Results: the prediction root mean square error from leave-one-out cross-validation is: 0.112 mm/month, 0.083 mm/month and 0.066 mm/month for local, PCA-based and PLS-derived shape features, respectively. Aneurysms close to the root with a large initial diameter report faster growth.
Conclusion: global shape features might provide an important contribution for predicting the aneurysm growth.2025-03-04T10:21:20ZVolume 162, August 2023, 107052, Computers in Biology and MedicineLeonardo GeronziAntonio MartinezMichel RochetteKexin YanAline Bel-BrunonPascal HaigronPierre EscrigJacques TomasiMorgan DanielAlain LalandeSiyu LinDiana Marcela Marin-CastrillonOlivier BouchotJean PorteriePier Paolo ValentiniMarco Evangelos Biancolini10.1016/j.compbiomed.2023.107052http://arxiv.org/abs/2502.13911v2Application of autoresonance in rapid beam extraction of synchrotrons2025-03-03T10:07:30ZIn recent years, ultra-high dose rate (FLASH) radiotherapy has become a novel cancer treatment technique because of its similar tumor-killing efficacy as conventional particle therapy while significantly protecting normal tissues. However, due to the limitation of particle number, achieving FLASH condition in a compact heavy-ion synchrotron requires a short extraction time of tens of milliseconds, which is challenging for the conventional RF-KO method. To tackle this challenge, we introduce autoresonance into the third-order resonant extraction for the first time, offering an alternative to the conventional approach of merely increasing the excitation strength. By leveraging a strong detuning effect, a frequency sweeping excitation with small amplitude can drive the entire beam into the autoresonant state, thus enabling rapid beam extraction within a single sweeping period. Compared with the conventional method, this innovative method requires only the addition of an octupole magnet. At the same time, it shows that the conventional RF-KO method has a high autoresonance threshold, so that only a small number of particles that meet the threshold can be excited to large amplitude and be extracted in each sweeping period. In this paper, the autoresonance threshold of a particle in the presence of sextupole and octupole magnetic fields is analyzed, and the single particle simulation shows good agreement with the theoretical formula. Furthermore, the autoresonance based rapid extraction process is simulated and studied, revealing the possibility of millisecond scale beam extraction.2025-02-19T17:43:39ZX. DingS. RuanH. RenG. WangR. H. ZhuJ. C. YangH. Zhaohttp://arxiv.org/abs/2503.01318v1MR-WAVES: MR Water-diffusion And Vascular Effects Simulations2025-03-03T09:01:45ZAccurate MR signal simulation, including microvascular structures and water diffusion, is crucial for MRI techniques like fMRI BOLD modeling and MR vascular Fingerprinting (MRF), which use susceptibility effects on MR signals for tissue characterization. However, integrating microvascular features and diffusion remains computationally challenging, limiting the accuracy of the estimates. Using advanced modeling and deep neural networks, we propose a novel simulation tool that efficiently accounts for susceptibility and diffusion effects. We used dimension reduction of magnetic field inhomogeneity matrices combined with deep learning method to accelerate the simulations while maintaining their accuracy. We validated our results through an in silico study against a reference method and in vivo MRF experiments. This approach accelerates MR signal generation by a factor of almost 13,000 compared to previously used simulation methods while preserving accuracy. The MR-WAVES method allows fast generation of MR signals accounting for microvascular structures and water-diffusion contribution.2025-03-03T09:01:45ZMain text: 10 pages, 8 figures, 1 table Submitted to Magnetic Resonance in Medicine (March 2025) The source code for our implementation is available here https://github.com/ThomasCoudert/MR-WAVES-publicThomas CoudertMaitê Silva Martins MarçalAurélien DelphinAntoine BarrierLila CungeLoïc LegrisJan M WarnkingBenjamin LemassonEmmanuel L BarbierThomas Christen10.1002/mrm.30629http://arxiv.org/abs/2503.01306v1From Claims to Evidence: A Unified Framework and Critical Analysis of CNN vs. Transformer vs. Mamba in Medical Image Segmentation2025-03-03T08:44:51ZWhile numerous architectures for medical image segmentation have been proposed, achieving competitive performance with state-of-the-art models networks such as nnUNet, still leave room for further innovation. In this work, we introduce nnUZoo, an open source benchmarking framework built upon nnUNet, which incorporates various deep learning architectures, including CNNs, Transformers, and Mamba-based models. Using this framework, we provide a fair comparison to demystify performance claims across different medical image segmentation tasks. Additionally, in an effort to enrich the benchmarking, we explored five new architectures based on Mamba and Transformers, collectively named X2Net, and integrated them into nnUZoo for further evaluation. The proposed models combine the features of conventional U2Net, nnUNet, CNN, Transformer, and Mamba layers and architectures, called X2Net (UNETR2Net (UNETR), SwT2Net (SwinTransformer), SS2D2Net (SwinUMamba), Alt1DM2Net (LightUMamba), and MambaND2Net (MambaND)). We extensively evaluate the performance of different models on six diverse medical image segmentation datasets, including microscopy, ultrasound, CT, MRI, and PET, covering various body parts, organs, and labels. We compare their performance, in terms of dice score and computational efficiency, against their baseline models, U2Net, and nnUNet. CNN models like nnUNet and U2Net demonstrated both speed and accuracy, making them effective choices for medical image segmentation tasks. Transformer-based models, while promising for certain imaging modalities, exhibited high computational costs. Proposed Mamba-based X2Net architecture (SS2D2Net) achieved competitive accuracy with no significantly difference from nnUNet and U2Net, while using fewer parameters. However, they required significantly longer training time, highlighting a trade-off between model efficiency and computational cost.2025-03-03T08:44:51ZPooya Mohammadi KazajGiovanni BajYazdan SalimiAnselm W. StarkWaldo ValenzuelaGeorge CM. SiontisHabib ZaidiMauricio ReyesChristoph GraeniIsaac Shirihttp://arxiv.org/abs/2407.15035v3Hemodynamic analysis of the Pulsatile Flow in Tubes of Bipolar Cross Sections2025-03-03T02:18:02ZPulsatile flow through compressed or defective blood vessels is a topic of fundamental importance in hemodynamics, particularly in cardiovascular research. This study examines flow dynamics within a tube with a bipolar cross section, possibly representing the geometry of bicuspid aortic valves (BAV), aortic bifurcations, and the aortic arch regions where non-uniform vessel shapes significantly influence hemodynamic behavior. An analytical solution is derived for the governing equations of pulsatile and poiseuille flow in a bipolar cross-sectional tube. The analysis focuses on the velocity field, flow rate, and wall shear stress (WSS) across different pulsation frequencies and geometric parameters, highlighting how these factors interact to shape flow characteristics. At low frequencies, the velocity profile remains smooth, with gradual acceleration and deceleration phases. In contrast, at higher frequencies, oscillatory effects become more pronounced, and the peak volume flow, initially occurring near $ωt=0$ and $ωt$=$π$, shifts toward an earlier phase in the cycle $ωt=0$ to $ωt=π/2)$ before stabilizing at very high frequencies. Shear stress behavior also exhibits frequency-dependent variations. At low frequencies, the fluid responds smoothly to pressure gradients, producing a shear stress distribution similar to steady flow. However, as frequency increases, inertial and unsteady effects introduce phase lags, leading to more complex shear stress patterns. These findings provide valuable insights into the interplay between vessel geometry and pulsatile forces, with implications for understanding disease progression and refining diagnostic models in cardiovascular medicine.2024-07-21T01:56:30Z DoyeolDavid Ahnhttp://arxiv.org/abs/2503.00920v1High-Q non-invasive Glucose Sensor using MicrostripLine Main Field and Split Ring Resonator2025-03-02T14:45:57ZA high-Q sensor integrating microstrip line (MLIN) main field and split ring resonators is presented for non-invasive glucose sensing. The proposed sensor combines the field-focusing effects of split ring resonators with the enhanced field substrate interaction properties of the MLIN main field, using the reflection coefficient (S11) of an open-ended MLIN with the finger as the substrate and operating at 750 MHz and 1.5 GHz. The permittivity of blood inside the finger depends on the glucose concentration, which in turn affects the S11 of the system. Sensor geometry was optimized using Method-of-Moments simulation before the sensor was fabricated and validated on standard solutions of glucose concentrations between 0 to 126 mg/dL within the physiological range, and a human test subject. In both experiments, a near inverse-linear relationship between the S11 peak magnitude and the glucose concentration was observed, demonstrating the sensitivity of the proposed sensor for detecting changes in blood glucose concentration at physiological conditions.2025-03-02T14:45:57ZBrandon Kaiheng TaySaumitra KapoorWenwei YuShao Ying Huanghttp://arxiv.org/abs/2503.00665v1Development of an Unpaired Deep Neural Network for Synthesizing X-ray Fluoroscopic Images from Digitally Reconstructed Tomography in Image Guided Radiotherapy2025-03-01T23:34:43ZPurpose The purpose of this study was to develop and evaluate a deep neural network (DNN) capable of generating flat-panel detector (FPD) images from digitally reconstructed radiography (DRR) images in lung cancer treatment, with the aim of improving clinical workflows in image-guided radiotherapy.
Methods A modified CycleGAN architecture was trained on paired DRR-FPD image data obtained from patients with lung tumors. The training dataset consisted of over 400 DRR-FPD image pairs, and the final model was evaluated on an independent set of 100 FPD images. Mean absolute error (MAE), peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and Kernel Inception Distance (KID) were used to quantify the similarity between synthetic and ground-truth FPD images. Computation time for generating synthetic images was also measured.
Results Despite some positional mismatches in the DRR-FPD pairs, the synthetic FPD images closely resembled the ground-truth FPD images. The proposed DNN achieved notable improvements over both input DRR images and a U-Net-based method in terms of MAE, PSNR, SSIM, and KID. The average image generation time was on the order of milliseconds per image, indicating its potential for real-time application. Qualitative evaluations showed that the DNN successfully reproduced image noise patterns akin to real FPD images, reducing the need for manual noise adjustments.
Conclusions The proposed DNN effectively converted DRR images into realistic FPD images for thoracic cases, offering a fast and practical method that could streamline patient setup verification and enhance overall clinical workflow. Future work should validate the model across different imaging systems and address remaining challenges in marker visualization, thereby fostering broader clinical adoption.2025-03-01T23:34:43ZChisako HayashiShinichiro MoriYasukuni MoriLim TaehyeungHiroki SuyariHitoshi Ishikawa