https://arxiv.org/api/7v1mTgtbZ3BEU86gLN6qC6zITMA2026-06-27T18:08:53Z9008151515http://arxiv.org/abs/2503.09505v1Pulsed laser diode excitation for transcranial photoacoustic imaging2025-03-12T16:16:53ZPhotoacoustic (PA) imaging of deep tissue tends to employ Q-switched lasers with high pulse energy to generate high optical fluence and therefore high PA signal. Compared to Q-switched lasers, pulsed laser diodes (PLDs) typically generate low pulse energy. In PA imaging applications with strong acoustic attenuation, such as through human skull bone, the broadband PA waves generated by nanoseconds laser pulses are significantly reduced in bandwidth during their propagation to a detector. As high-frequency PA signal components are not transmitted through skull, we propose to not generate them by increasing excitation pulse duration. Because PLDs are mainly limited in their peak power output, an increase in pulse duration linearly increases pulse energy and therefore PA signal amplitude. Here we show that the optimal pulse duration for deep PA sensing through thick skull bone is far higher than in typical PA applications. Counterintuitively, this makes PLD excitation well-suited for transcranial photoacoustics. We show this in PA sensing experiments on ex vivo human skull bone.2025-03-12T16:16:53Zsubmitted to Biomedical Optics ExpressMaxim N. CherkashinJan LauferThomas Kirchner10.1364/BOE.570037http://arxiv.org/abs/2503.09059v1Diffusing Alpha-emitters Radiation Therapy: In vivo Measurements of Effective Diffusion and Clearance Rates Across Multiple Tumor Types2025-03-12T04:52:40ZDiffusing alpha-emitters radiation therapy (Alpha-DaRT) is a new modality that uses alpha particles to treat solid tumors. Alpha-DaRT employs interstitial sources loaded with low activities of Radium-224, which release a chain of short-lived alpha-emitters diffusing over a few millimeters around each source. Alpha-DaRT dosimetry is described, to first order, by a framework called the diffusion-leakage (DL) model. The aim of this work is to estimate the tumor-specific parameters of the DL model from in-vivo studies on multiple histological cancer types. Autoradiography studies with phosphor imaging were conducted on 113 mice-borne tumors from 10 cancer cell lines. An observable, referred to as the effective diffusion length, Leff, was extracted from images of histological slices obtained using phosphor screens. The tumor and Alpha-DaRT source activities were measured after excision with a gamma counter to estimate the probability of Lead-212 clearance from the tumor by the blood, Pleak(Pb). The measured values of Leff are in the range of 0.2-0.7 mm across different tumor types and sizes. Pleak(Pb) is between 10% and 90% for all measured tumors, and it generally decreases in magnitude and spread for larger tumors. The measured values of Leff and Pleak(Pb) and associated dose calculations indicate that hexagonal Alpha-DaRT source lattices of ~4 mm spacing with muCi-scale Radium-224 activities can lead to effective coverage of the tumor volume with therapeutic dose levels, with considerable margin to compensate for local variations in diffusion and leakage.2025-03-12T04:52:40ZMirta DumancicGuy HegerIshai LuzMaayan VatarescuNoam WeizmanLior EpsteinTomer CooksLior Arazihttp://arxiv.org/abs/2503.08515v1Segmentation-Guided CT Synthesis with Pixel-Wise Conformal Uncertainty Bounds2025-03-11T15:07:16ZAccurate dose calculations in proton therapy rely on high-quality CT images. While planning CTs (pCTs) serve as a reference for dosimetric planning, Cone Beam CT (CBCT) is used throughout Adaptive Radiotherapy (ART) to generate sCTs for improved dose calculations. Despite its lower cost and reduced radiation exposure advantages, CBCT suffers from severe artefacts and poor image quality, making it unsuitable for precise dosimetry. Deep learning-based CBCT-to-CT translation has emerged as a promising approach. Still, existing methods often introduce anatomical inconsistencies and lack reliable uncertainty estimates, limiting their clinical adoption. To bridge this gap, we propose STF-RUE, a novel framework integrating two key components. First, STF, a segmentation-guided CBCT-to-CT translation method that enhances anatomical consistency by leveraging segmentation priors extracted from pCTs. Second, RUE, a conformal prediction method that augments predicted CTs with pixel-wise conformal prediction intervals, providing clinicians with robust reliability indicator. Comprehensive experiments using UNet++ and Fast-DDPM on two benchmark datasets demonstrate that STF-RUE significantly improves translation accuracy, as measured by a novel soft-tissue-focused metric designed for precise dose computation. Additionally, STF-RUE provides better-calibrated uncertainty sets for synthetic CT, reinforcing trust in synthetic CTs. By addressing both anatomical fidelity and uncertainty quantification, STF-RUE marks a crucial step toward safer and more effective adaptive proton therapy. Code is available at https://anonymous.4open.science/r/cbct2ct_translation-B2D9/.2025-03-11T15:07:16ZMICCAI 2025 Conference Submission. Follows the required LNCS format. 12 pages including references. Contains 4 figures and 1 tableDavid Vallmanya PochYorick EstievenartElnura ZhalievaSukanya PatraMohammad YaqubSouhaib Ben Taiebhttp://arxiv.org/abs/2503.07921v1Identification and Removal of System-Induced Autofluorescence in Miniaturized Fiber-optic Fluorescence Endoscopes2025-03-10T23:54:54ZMiniaturized fiber-optic fluorescence endoscopes play a crucial role in medical diagnostics and research, but system-induced autofluorescence remains a significant challenge, particularly in single-fiber setups. While recent advances, such as double-clad fiber (DCF) and DCF couplers, have reduced background noise, complete elimination remains challenging. Research on the various sources of system-induced autofluorescence and the methods to remove them are scarce. This study seeks to fulfill this need by proposing practical approaches to removal of system-induced autofluorescence. This study presents the methods to suppress static background noise and proposes an algorithm based on least-squares linear spectral unmixing to remove variable system-induced autofluorescence artifacts. The algorithm was evaluated on a single-fiber DCF intravascular imaging system, with phantom and rodent in vivo experiments confirming its effectiveness. Results showed accurate differentiation between true sample fluorescence and system-induced autofluorescence artifacts through the validation with optical coherence tomography images and histology results, further verified by statistical analysis. Unlike simple background subtraction, the method addresses dynamic variations in background noise and incidental artifacts, providing robust performance under varying conditions. Our method may be adapted to various fiber-based endoscopy setups and be compatible with different fluorescent agents and autofluorescence imaging, broadening its applicability in biomedical imaging.2025-03-10T23:54:54ZLei XiangRouyan ChenJoanne TanVictoria NankivellChristina A. BursillRobert A. McLaughlinJiawen Lihttp://arxiv.org/abs/2503.07293v1Is fitting error a reliable metric for assessing deformable motion correction in quantitative MRI?2025-03-10T13:16:30ZQuantitative MR (qMR) can provide numerical values representing the physical and chemical properties of the tissues. To collect a series of frames under varying settings, retrospective motion correction is essential to align the corresponding anatomical points or features. Under the assumption that the misalignment makes the discrepancy between the corresponding features larger, fitting error is a commonly used evaluation metric for motion correction in qMR. This study evaluates the reliability of the fitting error metric in cardiac diffusion tensor imaging (cDTI) after deformable registration. We found that while fitting error correlates with the negative eigenvalues, the negative Jacobian Determinant increases with broken cardiomyocytes, indicated by helix angle gradient line profiles. Since fitting error measures the distance between moved points and their re-rendered counterparts, the fitting parameter itself may be adjusted due to poor registration. Therefore, fitting error in deformable registration itself is a necessary but not sufficient metric and should be combined with other metrics.2025-03-10T13:16:30Z5 pages, 5 figures. Accepted by ISBI 2025Fanwen WangKe WenYaqing LuoYinzhe WuJiahao HuangDudley J. PennellPedro F. FerreiraAndrew D. ScottSonia Nielles-VallespinGuang Yanghttp://arxiv.org/abs/2503.07226v1Exact solutions to the cancer laser ablation modeling2025-03-10T12:12:01ZThe present paper deals with the study of the fluence rate over both healthy and tumor tissues in the presence of focal laser ablation (FLA). We propose new analytical solutions for the coupled partial differential equations (PDE) system, which includes the transport equation modeling the light penetration into biological tissue, the bioheat equation modeling the heat transfer and its respective damage. The present building could be the first step to the knowledge of the mathematical framework for biothermophysical problems, as well as the main key to simplify the numerical calculation due to its no cost. We derive exact solutions and simulate results from them. We discuss the potential physical contributions and present respective conclusions about (1) the validness of the diffusion approximation of the radiative transfer equation; (2) the local behavior of the source of scattered photons; (3) the unsteady-state of the fluence rate; and (4) the boundedness of the critical time of the thermal damage to the cancerous tissue. We also discuss some controversial and diverging hypotheses.2025-03-10T12:12:01Z21 pages, 4 figures, 5 tablesPhotonics 12 :4 (2025), 400Luisa Consiglieri10.3390/photonics12040400http://arxiv.org/abs/2503.07110v1A LSTM-Transformer Model for pulsation control of pVADs2025-03-10T09:33:59ZMethods: A method of the pulsation for a pVAD is proposed (AP-pVAD Model). AP-pVAD Model consists of two parts: NPQ Model and LSTM-Transformer Model. (1)The NPQ Model determines the mathematical relationship between motor speed, pressure, and flow rate for the pVAD. (2)The Attention module of Transformer neural network is integrated into the LSTM neural network to form the new LSTM-Transformer Model to predict the pulsation time characteristic points for adjusting the motor speed of the pVAD. Results: The AP-pVAD Model is validated in three hydraulic experiments and an animal experiment. (1)The pressure provided by pVAD calculated with the NPQ Model has a maximum error of only 2.15 mmHg compared to the expected values. (2)The pulsation time characteristic points predicted by the LSTM-Transformer Model shows a maximum prediction error of 1.78ms, which is significantly lower than other methods. (3)The in-vivo test of pVAD in animal experiment has significant improvements in aortic pressure. Animals survive for over 27 hours after the initiation of pVAD operation. Conclusion: (1)For a given pVAD, motor speed has a linear relationship with pressure and a quadratic relationship with flow. (2)Deep learning can be used to predict pulsation characteristic time points, with the LSTM-Transformer Model demonstrating minimal prediction error and better robust performance under conditions of limited dataset sizes, elevated noise levels, and diverse hyperparameter combinations, demonstrating its feasibility and effectiveness.2025-03-10T09:33:59ZChaoran EChenghan ChenYuyang ShiHaiyun WangPeixin HuaXiwen Zhanghttp://arxiv.org/abs/2503.06842v1A Simple Sonic Mapping Method Verified by CT Scan Images2025-03-10T02:09:07ZThis study presents a novel sonic mapping method applied to coal samples, verified by CT scan imaging. Cubic coal samples with side lengths of 50-70 mm were subjected to non-destructive sonic tests, measuring both P-wave (Vp) and S-wave (Vs) velocities. Each of the three orthogonal directions (X, Y, and Z) of the cube was divided into 9 regions, resulting in 27 Vp and 27 Vs measurements per sample. From these data, 2D sonic maps were constructed for each direction, and interpolation was employed to refine the mappings. A 3D sonic map was then generated by averaging the 2D maps. The 3D sonic mapping results were compared and validated against high-resolution CT scan images, confirming the reliability of this approach for mapping the internal structure of coal samples.2025-03-10T02:09:07ZJimmy Xuekai LiThomas FlottmannMax MillenShuai ChenYixiao HuangZhongwei Chenhttp://arxiv.org/abs/2503.06666v1Low contrast detection and super-resolution in CT images: evaluation of a novel approach based on Centroidal Voronoi Tessellation2025-03-09T15:30:44ZIn this work, image analysis techniques used in astrophysics to detect low-contrast signals have been adapted in the processing of Computed Tomography (CT) images, combining Centroidal Voronoi Tessellation (CVT) and machine learning techniques. Several CT acquisitions were performed using a phantom containing cylindrical inserts of different diameters producing objects with different contrasts respect to background. The images of the phantom, tilted by a known angle with respect to the tomograph axis (to mimic the casual orientation of a clinical lesion), were acquired at various radiation doses (CTDIvol) and at different slice's thicknesses. The success in detecting the signal in the single image (slice) was always greater than 60%. The axis of each insert has always been correctly identified. A super-resolution 2D image was then generated by projecting the individual slices of the scan along this axis, thus increasing the CNR of the object scanned as a whole. CVT holds great promise for future use in medical imaging, for the identification of low-contrast lesions in homogeneous organs, such as the liver.2025-03-09T15:30:44Z9 pages, 6 figuresSIF Congress 2022Lorenzo Lasagni10.1393/ncc/i2023-23071-4http://arxiv.org/abs/2503.06644v1The New CMS Measure of Excessive Radiation Dose or Inadequate CT Image Quality: Methods for Size-Adjusted Dose and Their Variabilities2025-03-09T14:43:25ZThe Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation of size-adjusted dose (SAD) using patient effective diameter and predefined size-adjustment coefficients. However, variability in SAD calculation methods raises concerns about standardization, compliance, and clinical applicability. This study evaluates five commonly used methods for estimating effective diameter and their impact on SAD determination in thoracic and abdominal CT protocols. A retrospective analysis of 719 CT exams was performed, comparing SAD values across different calculation approaches. Results indicate significant variability in SAD, with attenuation-based methods overestimating SAD in chest exams and projection-based methods exhibiting greater variability in abdominal exams. The findings highlight potential inconsistencies in CMS-defined dose thresholds and challenges in applying the measure across diverse patient populations and institutional imaging practices. Addressing these inconsistencies is critical for ensuring accurate dose reporting and maintaining diagnostic integrity in CT imaging.2025-03-09T14:43:25ZGary Y GeCharles M WeaverJie Zhanghttp://arxiv.org/abs/2503.06172v1Asymmetric Modular Pulse Synthesizer: A High-Power High-Granularity Electronics Solution for Transcranial Magnetic Stimulation with Practically Any Pulse Shape for Neural Activation Selectivity2025-03-08T11:22:51ZNoninvasive brain stimulation can activate neurons in the brain but requires power electronics with exceptionally high power in the mega-volt-ampere and high frequencies in the kilohertz range. Whereas oscillator circuits offered only one or very few pulse shapes, modular power electronics solved a long-standing problem for the first time and enabled arbitrary software-based design of the temporal shape of stimuli. However, synthesizing arbitrary stimuli with a high output quality requires a large number of modules. Systems with few modules and pulse-width modulation may generate apparently smooth current shapes in the highly inductive coil, but the stimulation effect of the neurons depends on the electric field and the electric field becomes a burst of ultra-brief rectangular pulses. We propose an alternative solution that achieves high-resolution pulse shaping with fewer modules by implementing high-power wide-bandwidth voltage asymmetry. Rather than equal voltage steps, our system strategically assigns different voltages to each module to achieve a near-exponential improvement in resolution. Compared to prior designs, our experimental prototype achieved better output quality, although it uses only half the number of modules.2025-03-08T11:22:51Z4 pages, 1 figureJinshui ZhangAngel PeterchevStefan Goetzhttp://arxiv.org/abs/2503.06131v1Comparative Time-Series Analysis of Hip and Shoulder Rotation in Baseball Bat Swings2025-03-08T08:56:36ZThis study focuses on the rotation of the hips and shoulders during a baseball bat swing, analyzing the time-series changes in rotational angles, rotational velocities, and axes using marker position data obtained from a motion capture system with 12 infrared cameras. Previous studies have examined factors such as ground reaction forces, muscle activation patterns, rotational energy, angular velocity, and angles during a swing. However, to the best of our knowledge, the hip and shoulder rotational motions have not been adequately visualized or compared. In particular, there is a lack of analysis regarding the coordination and timing differences between hip and shoulder movements during the swing. Therefore, this study aims to quantitatively compare the hip and shoulder rotational movements during the swing between skilled and unskilled players and visualizes the differences between them. Based on the obtained data, the study aims to improve the understanding of bat swing mechanics by visualizing the coordinated body movements during the swing.2025-03-08T08:56:36Z18 pages, 18 figuresKoga OkuboKanta Tachibanahttp://arxiv.org/abs/2503.06000v1Optimization models for needle placement in 3D-printed masks for high dose rate brachytherapy2025-03-08T01:02:40ZHigh dose rate brachytherapy (HDR-BT) is an appealing treatment option for superficial cancers that permits the delivery of higher local doses than other radiation modalities without a significant increase in toxicity. In order for HDR-BT to be used in these situations, needles through which the radiation source is passed must be strategically placed in close proximity to the patient's body. Currently, this crucial step is performed manually by physicians or medical physicists. The use of 3D-printed masks customized for individual patients has been advocated as a way to more precisely and securely position these needles, with the potential of producing better and safer treatment plans. In this paper, we propose optimization approaches for positioning needles within 3D-printed masks for HDR-BT, focusing on skin cancers. We numerically show that the models we propose efficiently generate more homogeneous plans than those derived manually and provide an alternative to manual placement that can save planning time and enhance plan quality.2025-03-08T01:02:40ZNasim Mirzavand BoroujeniJean-Philippe P. RichardDavid SterlingChristopher Wilkehttp://arxiv.org/abs/2503.05608v1Compact Accelerator-Based Production of Carrier-free $^{177}$Lu From 18 MeV $D^+$ on [$^{176}$Yb]Yb$_2$O$_3$2025-03-07T17:32:27ZWe use experimental and simulated excitation functions to estimate the yield of deuteron activations on a [$^{176}$Yb]Yb$_2$O$_3$ target enriched to 99%. Subsequent calculations are used to determine the production of radiotherapeutic $^{177}$Lu according to a 10 mA, 18 MeV $D^+$ compact linear accelerator. The design comprises a single radio-frequency quadrupole accelerator (RFQ) and seven drift tube linacs (DTLs) that achieve a beam efficiency of 99.5% over a length of $12\,\text{m}$. Our results show that a 5-day irradiation can yield more than $1$ mg of $^{177}$Lu, exceeding $4.4$ TBq. After a 2 day processing period, it is estimated that the sample will have a radiopurity greater than 99.8% (carrier-free). Given recent EMA and FDA approvals of $^{177}$Lu-DOTATATE and $^{177}$Lu-PSMA-617, our results confirm the viability of accelerator-based $^{177}$Lu production and provide a promising clinical alternative to reactor-based methods.2025-03-07T17:32:27ZAustin A. MorrisTianhao WeiZhi WangYing XiaMeiyun HanYuanrong Luhttp://arxiv.org/abs/2503.05569v1A-SEE2.0: Active-Sensing End-Effector for Robotic Ultrasound Systems with Dense Contact Surface Perception Enabled Probe Orientation Adjustment2025-03-07T16:51:29ZConventional freehand ultrasound (US) imaging is highly dependent on the skill of the operator, often leading to inconsistent results and increased physical demand on sonographers. Robotic Ultrasound Systems (RUSS) aim to address these limitations by providing standardized and automated imaging solutions, especially in environments with limited access to skilled operators. This paper presents the development of a novel RUSS system that employs dual RGB-D depth cameras to maintain the US probe normal to the skin surface, a critical factor for optimal image quality. Our RUSS integrates RGB-D camera data with robotic control algorithms to maintain orthogonal probe alignment on uneven surfaces without preoperative data. Validation tests using a phantom model demonstrate that the system achieves robust normal positioning accuracy while delivering ultrasound images comparable to those obtained through manual scanning. A-SEE2.0 demonstrates 2.47 ${\pm}$ 1.25 degrees error for flat surface normal-positioning and 12.19 ${\pm}$ 5.81 degrees normal estimation error on mannequin surface. This work highlights the potential of A-SEE2.0 to be used in clinical practice by testing its performance during in-vivo forearm ultrasound examinations.2025-03-07T16:51:29Z8 pages, submitted for reviewYernar ZhetpissovXihan MaKehan YangHaichong K. Zhang