https://arxiv.org/api/EdjaeBaqQsa/dhT9LFmq31qkiG82026-06-27T17:18:17Z9008150015http://arxiv.org/abs/2409.09993v2OpenDosimeter: Open Hardware Personal X-ray Dosimeter2025-03-19T08:12:07ZWe present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at $\pm$25% accuracy, tested for energies up to 120 keV. The maximum dose rate readings are limited by pile-up effects when approaching count rate saturation ($\sim$77 kcps at $\sim$13 $μ$s average pulse processing time). The total component cost for making an OpenDosimeter is <\$100, which, combined with its open design (both hardware and software), enables cost-effective local reproducibility on a global scale. Through a student workshop, we also demonstrate its effectiveness as an educational and capacity-building tool. This paper complements the open-source documentation by explaining the underlying technology, the algorithm for dose calculation, and areas for future improvement.2024-09-16T05:00:48Z9 pages, 4 figures Version 2: Added Figure 4 on the workshop at Strathmore Universty, organized by Pamela Kilavi (added as co-author). Added corresponding text in the Results, Discussion, and Methods section, and updated the abstract to include the workshopCommun Eng 4, 207 (2025)Norah GerAlice KuJasmyn LopezN. Robert BennettJia WangGrace AtekaEnoch AnyendaMatthias RosezkyPamela KilaviAdam S. WangKian Shaker10.1038/s44172-025-00540-0http://arxiv.org/abs/2503.14933v1A Language Vision Model Approach for Automated Tumor Contouring in Radiation Oncology2025-03-19T06:41:37ZBackground: Lung cancer ranks as the leading cause of cancer-related mortality worldwide. The complexity of tumor delineation, crucial for radiation therapy, requires expertise often unavailable in resource-limited settings. Artificial Intelligence(AI), particularly with advancements in deep learning (DL) and natural language processing (NLP), offers potential solutions yet is challenged by high false positive rates. Purpose: The Oncology Contouring Copilot (OCC) system is developed to leverage oncologist expertise for precise tumor contouring using textual descriptions, aiming to increase the efficiency of oncological workflows by combining the strengths of AI with human oversight. Methods: Our OCC system initially identifies nodule candidates from CT scans. Employing Language Vision Models (LVMs) like GPT-4V, OCC then effectively reduces false positives with clinical descriptive texts, merging textual and visual data to automate tumor delineation, designed to elevate the quality of oncology care by incorporating knowledge from experienced domain experts. Results: Deployments of the OCC system resulted in a significant reduction in the false discovery rate by 35.0%, a 72.4% decrease in false positives per scan, and an F1-score of 0.652 across our dataset for unbiased evaluation. Conclusions: OCC represents a significant advance in oncology care, particularly through the use of the latest LVMs to improve contouring results by (1) streamlining oncology treatment workflows by optimizing tumor delineation, reducing manual processes; (2) offering a scalable and intuitive framework to reduce false positives in radiotherapy planning using LVMs; (3) introducing novel medical language vision prompt techniques to minimize LVMs hallucinations with ablation study, and (4) conducting a comparative analysis of LVMs, highlighting their potential in addressing medical language vision challenges.2025-03-19T06:41:37Z19 pages, 4 figuresYi LuoHamed HooshangnejadXue FengGaofeng HuangXiaojian ChenRui ZhangQuan ChenWil NgwaKai Dinghttp://arxiv.org/abs/2503.14395v1Weakly Supervised Spatial Implicit Neural Representation Learning for 3D MRI-Ultrasound Deformable Image Registration in HDR Prostate Brachytherapy2025-03-18T16:30:08ZPurpose: Accurate 3D MRI-ultrasound (US) deformable registration is critical for real-time guidance in high-dose-rate (HDR) prostate brachytherapy. We present a weakly supervised spatial implicit neural representation (SINR) method to address modality differences and pelvic anatomy challenges.
Methods: The framework uses sparse surface supervision from MRI/US segmentations instead of dense intensity matching. SINR models deformations as continuous spatial functions, with patient-specific surface priors guiding a stationary velocity field for biologically plausible deformations. Validation included 20 public Prostate-MRI-US-Biopsy cases and 10 institutional HDR cases, evaluated via Dice similarity coefficient (DSC), mean surface distance (MSD), and 95% Hausdorff distance (HD95).
Results: The proposed method achieved robust registration. For the public dataset, prostate DSC was $0.93 \pm 0.05$, MSD $0.87 \pm 0.10$ mm, and HD95 $1.58 \pm 0.37$ mm. For the institutional dataset, prostate CTV achieved DSC $0.88 \pm 0.09$, MSD $1.21 \pm 0.38$ mm, and HD95 $2.09 \pm 1.48$ mm. Bladder and rectum performance was lower due to ultrasound's limited field of view. Visual assessments confirmed accurate alignment with minimal discrepancies.
Conclusion: This study introduces a novel weakly supervised SINR-based approach for 3D MRI-US deformable registration. By leveraging sparse surface supervision and spatial priors, it achieves accurate, robust, and computationally efficient registration, enhancing real-time image guidance in HDR prostate brachytherapy and improving treatment precision.2025-03-18T16:30:08ZJing WangRuirui LiuYu LeiMichael J. BaineTian LiuYang Leihttp://arxiv.org/abs/2503.14386v1A Comprehensive Scatter Correction Model for Micro-Focus Dual-Source Imaging Systems: Combining Ambient, Cross, and Forward Scatter2025-03-18T16:21:45ZCompared to single-source imaging systems, dual-source imaging systems equipped with two cross-distributed scanning beams significantly enhance temporal resolution and capture more comprehensive object scanning information. Nevertheless, the interaction between the two scanning beams introduces more complex scatter signals into the acquired projection data. Existing methods typically model these scatter signals as the sum of cross-scatter and forward scatter, with cross-scatter estimation limited to single-scatter along primary paths. Through experimental measurements on our selfdeveloped micro-focus dual-source imaging system, we observed that the peak ratio of hardware-induced ambient scatter to single-source projection intensity can even exceed 60%, a factor often overlooked in conventional models. To address this limitation, we propose a more comprehensive model that decomposes the total scatter signals into three distinct components: ambient scatter, cross-scatter, and forward scatter. Furthermore, we introduce a cross-scatter kernel superposition (xSKS) module to enhance the accuracy of cross-scatter estimation by modeling both single and multiple crossscatter events along non-primary paths. Additionally, we employ a fast object-adaptive scatter kernel superposition (FOSKS) module for efficient forward scatter estimation. In Monte Carlo (MC) simulation experiments performed on a custom-designed waterbone phantom, our model demonstrated remarkable superiority, achieving a scatter-toprimary-weighted mean absolute percentage error (SPMAPE) of 1.32%, significantly lower than the 12.99% attained by the state-of-the-art method. Physical experiments further validate the superior performance of our model in correcting scatter artifacts.2025-03-18T16:21:45ZJianing SunJigang DuanGuangyin LiXu JiangXing Zhaohttp://arxiv.org/abs/2503.14567v1SpecReX: Explainable AI for Raman Spectroscopy2025-03-18T10:49:15ZRaman spectroscopy is becoming more common for medical diagnostics with deep learning models being increasingly used to leverage its full potential. However, the opaque nature of such models and the sensitivity of medical diagnosis together with regulatory requirements necessitate the need for explainable AI tools. We introduce SpecReX, specifically adapted to explaining Raman spectra. SpecReX uses the theory of actual causality to rank causal responsibility in a spectrum, quantified by iteratively refining mutated versions of the spectrum and testing if it retains the original classification. The explanations provided by SpecReX take the form of a responsibility map, highlighting spectral regions most responsible for the model to make a correct classification. To assess the validity of SpecReX, we create increasingly complex simulated spectra, in which a "ground truth" signal is seeded, to train a classifier. We then obtain SpecReX explanations and compare the results with another explainability tool. By using simulated spectra we establish that SpecReX localizes to the known differences between classes, under a number of conditions. This provides a foundation on which we can find the spectral features which differentiate disease classes. This is an important first step in proving the validity of SpecReX.2025-03-18T10:49:15ZAAAI Workshop on Health Intelligencee (W3PHIAI-25)Nathan BlakeDavid A. KellyAkchunya ChanchalSarah Kapllani-MucajGeraint ThomasHana Chocklerhttp://arxiv.org/abs/2503.14087v1Demonstration of a mechanical external biventricular assist device for resuscitative thoracotomy2025-03-18T10:07:34ZResuscitative thoracotomy, a high-risk procedure involving open heart massage, serves as a last resort for life-threatening conditions like penetrating chest wounds, severe blunt trauma, or surgery-related cardiac arrest. However, its success rate remains low, even with highly trained specialists. This research investigates the potential of an external biventricular assist device (BiVAD). By replacing open heart massage with our BiVAD device during resuscitative thoracotomy, we aim to achieve sufficient cardiac output, maintain physiological pressure levels, and potentially improve patient survival in these critical situations. The proposed BiVAD system features a simple 3D printed patch design for direct cardiac attachment, an actuation device, and a vacuum pump. The straightforward design allows quick application in emergency situations. The BiVAD system was tested in a hydraulic mock circulation, utilizing a silicone heart. Three actuation modes were tested for proof-of-concept: manual patch actuation, standard cardiac hand massage, and utilizing full capabilities of our BiVAD patch system with actuation device operation. Overall performance was assessed on ventricular pressure and flow rate data. Focusing on achieving the optimal cardiac output of 1.5 L/min (critical for patient survival), we tested our patch system against cardiac hand massage at a fixed rate of 60 bpm. Notably, our BiVAD system not only achieved to operate in the range of required cardiac output but also significantly reduced peak pressure in both ventricles compared to standard cardiac hand massage. This initial evaluation using a silicone heart model demonstrates the potential of our BiVAD system to achieve sufficient cardiac output while reducing peak pressure compared to cardiac hand massage. Further development holds promise for effective cardiac support in resuscitative thoracotomy.2025-03-18T10:07:34ZKristóf SárosiThomas KummerThomas RösgenStijn VandenbergheStefanos DemertzisPatrick Jennyhttp://arxiv.org/abs/2503.13723v1Fast Maximum Likelihood Positioning for a Staggered Layer Scintillation PET Detector2025-03-17T21:11:30ZIn this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer design with pixelated scintillators enables the determination of the gamma's depth of interaction and facilitates an iteration-free formulation of the MLP algorithm. The efficacy of the algorithm optimization was tested on a scintillation detector block designed for an ultra-high field BrainPET 7T, comprising three scintillator pixel layers. The three layers contain 24 x 24, 24 x 23 and 23 x 22 scintillator pixels, respectively, with a pixel pitch of 2 mm in both directions and layer thicknesses of 9, 8 and 7 mm. Calibration measurements, in combination with an automated calibration script, were used to obtain the expected counts of scintillation photons required in the MLP algorithm. Using Single-Instruction-Multiple-Data parallelization, multi-threading and optimized cache lines, a maximum processing speed of approximately 22.5 million singles per second was achieved on a platform with four Intel Xeon Platinum 8168 CPUs and 60 threads, encompassing all required processing steps. The automatic calibration failed for 1 to 15 individual scintillator pixels in approximately 10 per cent of the 120 scintillation detector blocks, necessitating manual correction. After applying the energy correction to the positioned single events, an energy resolution of of 12 +/- 2 per cent FWHM was obtained for the entire scintillation block. This value is very close to the energy resolutions measured for the individual scintillator pixels, proving that the MLP accurately identifies the scintillating pixel and that the energy correction method effectively compensates for the light collection variations of the SiPM array.2025-03-17T21:11:30Z20 pages, 3 figuresChristoph W. LercheInstitute for Neuroscience and MedicineWenwei BiInstitute for Neuroscience and MedicineDepartment of Physics RWTH Aachen University Aachen GermanyMirjam SchoeneckInstitute for Neuroscience and MedicineM. Schoeneck is now with the Faculty of Medicine and Institute for Diagnostic and Interventional Radiology University Hospital Cologne GermanyDebora NiekaemperInstitute for Neuroscience and MedicineDepartment of Physics RWTH Aachen University Aachen GermanyQi LiuInstitute for Neuroscience and MedicineElisabeth PfaehlerInstitute for Neuroscience and MedicineLutz TellmannInstitute for Neuroscience and MedicineJuergen J. ScheinsInstitute for Neuroscience and MedicineN. Jon ShahInstitute for Neuroscience and MedicineInstitute of Neuroscience and Medicine 11JARA - BRAIN - Translational MedicineDepartment of Neurology RWTH Aachen University Aachen Germany10.1088/1361-6560/adf8abhttp://arxiv.org/abs/2304.07588v10Systematic Review on Learning-based Spectral CT2025-03-17T16:01:42ZSpectral computed tomography (CT) has recently emerged as an advanced version of medical CT and significantly improves conventional (single-energy) CT. Spectral CT has two main forms: dual-energy computed tomography (DECT) and photon-counting computed tomography (PCCT), which offer image improvement, material decomposition, and feature quantification relative to conventional CT. However, the inherent challenges of spectral CT, evidenced by data and image artifacts, remain a bottleneck for clinical applications. To address these problems, machine learning techniques have been widely applied to spectral CT. In this review, we present the state-of-the-art data-driven techniques for spectral CT.2023-04-15T16:07:31Z26 pages, 5 figuresAlexandre BousseVenkata Sai Sundar KandarpaSimon RitAlessandro PerelliMengzhou LiGuobao WangJian ZhouGe Wang10.1109/TRPMS.2023.3314131http://arxiv.org/abs/2412.15018v2Joint estimation of activity, attenuation and motion in respiratory-self-gated time-of-flight PET2025-03-17T11:31:52ZWhole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET. These methods enable the reconstruction of a single activity image free from motion and attenuation artifacts.
The proposed methods were evaluated using data from the anthropomorphic Wilhelm phantom acquired on a Siemens mCT PET/CT system, as well as 3 clinical FDG PET/CT datasets acquired on a GE DMI PET/CT system. Image quality was assessed visually to identify motion and attenuation artifacts. Lesion uptake values were quantitatively compared across reconstructions without motion modeling, with motion modeling but static attenuation correction, and with our proposed methods.
For the Wilhelm phantom, the proposed methods delivered image quality closely matching the reference reconstruction from a static acquisition. The lesion-to-background contrast for a liver dome lesion improved from 2.0 (no motion correction) to 5.2 (proposed methods), matching the contrast from the static acquisition (5.2). In contrast, motion modeling with static attenuation correction yielded a lower contrast of 3.5. In patient datasets, the proposed methods successfully reduced motion artifacts in lung and liver lesions and mitigated attenuation artifacts, demonstrating superior lesion to background separation.
Our proposed methods enable the reconstruction of a single, high-quality activity image that is motion-corrected and free from attenuation artifacts, without the need for external hardware.2024-12-19T16:30:56Z18 pages, 7 figures, 2 tablesMasoud ElhamiaslFrederic JolivetAhmadreza RezaeiMichael FieselerKlaus SchäfersJohan NuytsGeorg SchrammFernando Boada10.1088/1361-6560/adbed5http://arxiv.org/abs/2503.12515v1AI-Powered Automated Model Construction for Patient-Specific CFD Simulations of Aortic Flows2025-03-16T14:18:25ZImage-based modeling is essential for understanding cardiovascular hemodynamics and advancing the diagnosis and treatment of cardiovascular diseases. Constructing patient-specific vascular models remains labor-intensive, error-prone, and time-consuming, limiting their clinical applications. This study introduces a deep-learning framework that automates the creation of simulation-ready vascular models from medical images. The framework integrates a segmentation module for accurate voxel-based vessel delineation with a surface deformation module that performs anatomically consistent and unsupervised surface refinements guided by medical image data. By unifying voxel segmentation and surface deformation into a single cohesive pipeline, the framework addresses key limitations of existing methods, enhancing geometric accuracy and computational efficiency. Evaluated on publicly available datasets, the proposed approach demonstrates state-of-the-art performance in segmentation and mesh quality while significantly reducing manual effort and processing time. This work advances the scalability and reliability of image-based computational modeling, facilitating broader applications in clinical and research settings.2025-03-16T14:18:25Z42 pages, 8 figuresPan DuDelin AnChaoli WangJian-Xun Wanghttp://arxiv.org/abs/2503.10887v1Minimizing Human-Induced Variability in Quantitative Angiography for Robust and Explainable AI-Based Occlusion Prediction2025-03-13T21:19:41ZBias from contrast injection variability is a significant obstacle to accurate intracranial aneurysm occlusion prediction using quantitative angiography and deep neural networks . This study explores bias removal and explainable AI for outcome prediction. This study used angiograms from 458 patients with flow diverters treated IAs with six month follow up defining occlusion status. We minimized injection variability by deconvolving the parent artery input to isolate the impulse response of aneurysms, then reconvolving it with a standardized injection curve. A deep neural network trained on these QA derived biomarkers predicted six month occlusion. Local Interpretable Model Agnostic Explanations identified the key imaging features influencing the model, ensuring transparency and clinical relevance.2025-03-13T21:19:41ZParmita MondalMohammad Mahdi Shiraz BhurwaniSwetadri Vasan Setlur NageshPui Man Rosalind LaiJason DaviesElad LevyKunal VakhariaMichael R LevittAdnan H SiddiquiCiprian N Ionitahttp://arxiv.org/abs/2503.10396v1Analysis of the Institutional Free Market in Accredited Medical Physics Graduate Programs2025-03-13T14:15:51ZMedical Physics education is delivered through accredited programs with admissions and funding for students determined by individual institutions providing the educational experiences. Public data from accredited graduate programs, along with funding data, were used to analyze institutional trends in this educational market. Temporal trends from 2017 to 2023 show robust growth in MS graduates, increasing at an average of 17.7 per year, as compared to steady but modest growth in PhDs, increasing by 3.6 per year. The current status is there are nearly two MS graduates for every PhD graduate. Trends in funding show self-funding of students is a dominant pathway in domestic programs. Those programs dominated by accredited MS education have their largest fraction of faculty in radiation oncology departments, whereas those dominated by PhD education have their largest fraction of faculty in radiology departments. Overall NIH funding in the space of radiation diagnostics and therapeutics has been largely static over this timeframe, but with a notable 5 year rise in NCI funding. This can be contrasted to a substantial 5X-6X rise in NIH funding for engineering research in this same period, with significant increases in trainee funding there. Taken as a whole, this survey shows that growth in the field of medical physics education is dominated by MS graduates, presumably servicing the expanded growth needs for well-trained clinical physicists. However, the research infrastructure that supports PhD training in medical physics seems likely to be growing modestly and missing the growth trend of NIH funding that appears to show substantially more growth in non-accredited programs such as biomedical engineering. This data is useful to informing accreditation guidance on numbers of graduates to match the workforce needs or for inter-institutional planning around education goals.2025-03-13T14:15:51Z10 pages, 5 figures, original scientific research paperBrian W. PogueAlexander P. Niverhttp://arxiv.org/abs/2503.10317v1Linking Fluorescence Spectroscopy and 31P MRS in NADH Phantoms2025-03-13T12:52:11ZGlioblastoma exhibits significant metabolic alterations, making tracking energy metabolism important for its characterization. This could be crucial for glioblastoma resection in neurosurgery. We link two NADH monitoring methods, showing linear dependence on phantom concentrations.2025-03-13T12:52:11ZGiorgi AsatianiArthur GautheronLaurent Mahieu-WilliameHélène RatineyBruno Montcelhttp://arxiv.org/abs/2401.01557v2Compact dose delivery of laser-accelerated high-energy electron beams towards radiotherapy applications2025-03-13T02:34:03ZThe use of very high energy electron (VHEE) beams for radiotherapy has been actively studied for over two decades due to their advantageous dose distribution, deep penetration depth and great potential of ultra-high dose-rate irradiation. Recently, laser-plasma wakefield accelerator (LWFA) has emerged as a promising method for the compact generation of VHEE beams, due to its substantially higher accelerating gradients compared to traditional radio-frequency accelerators. However, how to compactly deliver the LWFA-based VHEE beams of relatively large energy spread and create a maximum dose deeply inside the body remains very challenging. In this article, we present a simple dose delivery scheme utilizing only two dipole magnets for LWFA-based VHEE treatment. By adjusting the magnet strengths, the electron beams can be guided along different angular trajectories towards a precise position as deep as 20 cm within a water phantom, creating a maximum dose over the target region and significantly reducing the entrance dose. Supported by Monte Carlo simulations, such a beam delivery approach is demonstrated to be insensitive to the beam energy spread and meanwhile capable of controlling precisely the dose-peak position in both lateral and longitudinal directions. As such, a uniform dose peak can be generated by the weighted sum of VHEE beams that reach different dose-peak depths. These results demonstrate that LWFA-based VHEE beams can be compactly delivered into a deep-seated tumor region in a controllable manner, thus advancing the development of the VHEE radiotherapy towards the practical clinical applications in the near future.2024-01-03T06:14:39Z14 pages, 5 figuresBing ZhouZhiyuan GuoYang WanShuang LiuJianfei HuaWei Lu10.1103/xdsm-7xmfhttp://arxiv.org/abs/2410.11504v2Physically motivated projection of the electrocardiogram -- a feasibility study2025-03-12T21:30:23ZWe present PhysECG: a physically motivated projection of the 12 lead electrocardiogram, supported by a deep learning model trained on 21,799 recordings from the PTB-XL database and discuss its feasibility. The method allows to evaluate the epicardial activity (inverse problem of ECG imaging) and, in particular, to distinguish left and right ventricular activity, with statistical spread related to localization of the septum. The observed dyssynchrony resembles other experimental results. The foundations of the method are based on the molecular theory of biopotentials. The heart's activity in view of the method is decomposed into two processes: the passage of the electric activation wavefront and the response of cardiomyocytes. We introduce the idea of the electrode-resolved activity function, which represents the mass of the ventricle in Phase 0 of action potential within the lead field of each electrode. The computations are fast and robust, with excellent convergence. We present the quality metrics for the reconstruction based on the model on the testing set selected from the PTB database. In order to prove feasibility, we present and discuss two healthy controls: male and female, and two pathologies: right bundle branch block, and anterior myocardial infarction. The results obtained using PhysECG seem to be in accordance with the changes evoked by pathology, which has to be confirmed by subsequent clinical studies. The method is based on ECG, and does not require reconstruction of body geometry, which presents an affordable solution for low and middle-income countries where access to imaging is limited.2024-10-15T11:17:08Z26 pages, 11 figuresSebastian WildowiczTomasz GradowskiPaulina FiguraIgor OlczakJudyta SobiechTeodor Buchner10.1016/j.bbe.2025.03.001