https://arxiv.org/api/5hYxqRqz346ta95EvzKPXjTaNow2026-06-21T13:50:40Z898515015http://arxiv.org/abs/2605.05491v1Pulse-Width-Specific Phase Space Informed Universal Beam Modeling for UHDR electron LINAC in FLASH-RT2026-05-06T22:26:33ZCommercial treatment planning systems for electron FLASH radiotherapy are unavailable, and the dosimetric precision required for ultra-high dose rate delivery makes Monte Carlo (MC) simulation the gold standard approach. This work establishes a methodology for generating pulse-width-specific phase space (PHSP) files for the Mobetron UHDR system (9 MeV), accounting for systematic beam quality shifts caused by RF waveguide loading across pulse widths of 1.2-4.0 microsecond. Using GAMOS 6.2.0, source parameters were iteratively refined against experimental targets: mean energy was optimized by matching phantom-measured R50 in the fall-off region, while energy spread was refined using surface dose and build-up gradients. Relationships derived from a mid-range 6 cm aperture were applied across all clinical configurations (2.5-10 cm) to test the aperture-independence of beam loading effects. Mean energy decreased exponentially from 9.58 to 9.04 MeV (R^2=0.99) with increasing pulse width, while energy spread increased quadratically (R^2=0.99), with a strong negative correlation (r=-0.98). Cross-aperture validation confirmed that energy shifts are independent of downstream collimation. The geometric mean pulse width (2.28 microsecond) was evaluated as a universal clinical reference, yielding 9.32 MeV mean energy. Across experimental extremes, R50 deviations were within 1.3 mm and critical depth-dose parameters remained within 2.0 mm, meeting AAPM TG-106 tolerances. Validated regression models enable beam parameter prediction at arbitrary pulse widths, and the universal reference reduces computational burden by 75% while maintaining clinical accuracy.2026-05-06T22:26:33Z17 pages, 7 figuresRafael CarballeiraThayer School of Engineering, Dartmouth College, Hanover, New HampshireDavid J. GladstoneThayer School of Engineering, Dartmouth College, Hanover, New HampshireDartmouth Cancer Center, Lebanon, New HampshireKevin J. WillyThayer School of Engineering, Dartmouth College, Hanover, New HampshirePhilip Von-Voigts RhetzIntraOp Medical Corporation, Sunnyvale, CaliforniaRongxiao ZhangThayer School of Engineering, Dartmouth College, Hanover, New HampshireSchool of Medicine, University of Missouri, Columbia, Missourihttp://arxiv.org/abs/2605.01538v2Automatic Aberration Correction for Transcranial Functional and Super-Resolution Ultrasound Imaging in Rodents and Nonhuman Primates2026-05-06T21:06:50ZSkull-induced aberrations remain a major drawback of transcranial ultrasound localization microscopy (ULM), degrading sensitivity and spatial accuracy through microbubble mislocalization, false detections, and imaging artifacts, such as disconnected or duplicated vessels. Here, we present a differentiable beamforming framework for automatic aberration correction in transcranial Doppler and ULM. Our approach uses spatially distributed delay-based parameterization of the aberration that is optimized in a closed-loop manner using angular coherence as an objective function. We demonstrate robust improvements of transcranial ULM, in vivo, with enhanced resolution of both mouse and nonhuman primate (NHP) brains. We also extended differentiable beamforming to functional measurements, with improvements in the sensitivity of transcranial functional ultrasound (fUS) and ULM based hemodynamic quantification. Extending this approach to 3D transcranial ULM imaging in NHPs, we show efficient correction of skull induced aberrations and removal of artifacts, such as vessel duplications. By providing a fully automated and generalizable solution for aberration correction, this work lowers a major technical barrier to transcranial ultrasound imaging, enabling broader adoption of non-invasive, super-resolution and functional neuroimaging across laboratories and across species.2026-05-02T17:03:31ZPaul XingAntoine MalescotEric MartineauStephan QuessyRavi L. RungtaNuma DancauseJean Provosthttp://arxiv.org/abs/2605.05175v1MRI-Eval: A Tiered Benchmark for Evaluating LLM Performance on MRI Physics and GE Scanner Operations Knowledge2026-05-06T17:42:01ZBackground: Existing MRI LLM benchmarks rely mainly on review-book multiple-choice questions, where top proprietary models already score highly, limiting discrimination. No systematic benchmark has evaluated vendor-specific scanner operational knowledge central to research MRI practice. Purpose: We developed MRI-Eval, a tiered benchmark for relative model comparison on MRI physics and GE scanner operations knowledge using primary multiple-choice questions (MCQ), with stem-only and primed diagnostic conditions as complementary analyses. Methods: MRI-Eval includes 1365 scored items across nine categories and three difficulty tiers from textbooks, GE scanner manuals, programming course materials, and expert-generated questions. Five model families were evaluated (GPT-5.4, Claude Opus 4.6, Claude Sonnet 4.6, Gemini 2.5 Pro, Llama 3.3 70B). MCQ was primary; stem-only removed options and used an independent LLM judge; primed stem-only tested responses to incorrect user claims. Results: Overall MCQ accuracy was 93.2% to 97.1%. GE scanner operations was the lowest category for every model (88.2% to 94.6%). In stem-only, frontier-model accuracy fell to 58.4% to 61.1%, and Llama 3.3 70B fell to 37.1%; GE scanner operations stem-only accuracy was 13.8% to 29.8%. Conclusion: High MCQ performance can mask weak free-text recall, especially for vendor-specific operational knowledge. MRI-Eval is most informative as a relative comparison benchmark rather than an absolute competency measure and supports caution in using raw LLM outputs for GE-specific protocol guidance.2026-05-06T17:42:01Z21 pages, 4 figures, 10 tablesPerry E. Radauhttp://arxiv.org/abs/2605.04596v1A Physics-Constrained Learning Framework for Wave Propagation in Complex Poroelastic Multilayered Media2026-05-06T07:42:31ZWave propagation through complex poroelastic multilayered media is difficult to model and invert because pronounced heterogeneity, scattering, mode conversion and fluid-solid coupling jointly distort acoustic signals during propagation. Here we present Physics-Constrained Learning for Complex Multilayered Media (PCL-CMM), a general framework that integrates Biot's poroelastic theory with the elastic wave equation to bridge the gap between physically rigorous wave modelling and data-driven learning. PCL-CMM constructs a high-fidelity digital twin that dynamically computes an effective acoustic stiffness tensor for forward wave modelling and incorporates the resulting physical constraint as a loss term to regularize the training of deep neural networks. We demonstrate PCL-CMM on transcranial photoacoustic imaging, where skull-induced acoustic distortions severely degrade image formation. Across simulations and ex vivo experiments, PCL-CMM effectively compensates for these distortions and improves SSIM by more than 0.06 compared with purely data-driven neural networks. This work establishes a physics-constrained learning framework for acoustic wave modelling in complex poroelastic multilayered media.2026-05-06T07:42:31Z30 pages,8 figures,2 tablesYa GaoYifan WangYiming ChenHaohan SunShoukun LyuJunmei CaoWeijiang XuQian Chenghttp://arxiv.org/abs/2605.04520v1Development and Validation of Patient-Specific Monte Carlo Dosimetry for Synchrotron Breast Phase-Contrast CT2026-05-06T05:58:08ZThis study develops and validates a patient-specific Monte Carlo (MC) dosimetry framework for propagation-based phase-contrast breast CT (BCT) at the Imaging and Medical Beamline (IMBL), ANSTO Australian Synchrotron, for accurate mean glandular dose (MGD) estimation. BCT provides 3D imaging without breast compression, improving comfort and visualization of internal structures for cancer detection. Propagation-based phase contrast improves soft-tissue contrast at equal or lower dose than conventional systems. Accurate dosimetry remains essential for safety and optimisation. Most MC-based MGD studies use non-patient-specific phantoms that ignore anatomical variability, while existing patient-specific methods lack a unified framework. Here, a voxel-based MC framework using EGSnrc was implemented to compute MGD in realistic anthropomorphic breast phantoms derived from synchrotron BCT images. IMBL beam characteristics were used as source inputs. Homogeneous phantoms were also generated to compute air Kerma to MGD conversion coefficients (DgN) for comparison with heterogeneous models. Simulations covered breast height, skin thickness, and photon energies (28 to 38 keV). Results show MGD depends strongly on anatomy and energy. Higher glandular density reduces MGD, while larger breast volume increases dose. A 2 mm increase in skin thickness reduces MGD by 10%. Differences between heterogeneous and homogeneous phantoms show variations in DgN, highlighting the need for anatomical realism. The framework provides a robust basis for patient-specific dosimetry in synchrotron phase-contrast BCT, enabling precise MGD estimation and supporting safe, optimised clinical imaging. This supports improved protocol design and contributes to standardised patient-specific dosimetry for clinical translation across varying breast anatomies and imaging conditions within synchrotron BCT applications.2026-05-06T05:58:08ZAmir EntezamAshkan PakzadChristopher J. HallAnton MaksimenkoMatthew John CameronAdam RoundMojtaba Hoseini-GhahfarokhiSeyedamir T. TabaYakov I. NesteretsDaniel HausermannMagdalena Bazalova-CarterPatrick C. BrennanTimur E. GureyevHarry M. Quineyhttp://arxiv.org/abs/2605.03931v1Measurement of the neutron shielding efficacy of magnetite for Proton Therapy Facilities and other applications2026-05-05T16:20:42ZThe neutron shielding properties of high-density concrete and magnetite aggregates were evaluated using both experimental measurements and Monte Carlo simulations. Because these materials are commonly used in medical accelerator facilities, it is essential to characterize their behavior under neutron radiation to ensure adequate shielding performance. Our experimental results show good agreement with the Monte Carlo calculations, confirming the reliability of the simulation approach. The attenuated neutron doses for various shielding thicknesses were determined for each aggregate type based on simulation and then compared as dose ratios. The findings indicate that magnetite provides superior neutron shielding, exhibiting a shorter attenuation length than conventional concrete for the same barrier thickness. The neutron attenuation characteristics of both concrete and magnetite were studied for typical neutron spectra encountered in clinical proton-therapy accelerators, including treatment rooms, primary, secondary barriers, and mazes. These results can support the optimization of radiation-shielding designs in medical and research facilities.2026-05-05T16:20:42Z9 pages, 9 figures, submit to NIM-BKijun ParkCynthia KeppelPawel AmbrozewiczKenneth WrightMichael Kosinskihttp://arxiv.org/abs/2605.02615v1TRACED: In vivo imaging of extracellular intrinsic diffusivity, tortuosity, cell size distribution and cell density in human glioma patients2026-05-04T14:03:48ZThe lack of analytical models describing diffusion time dependence at intermediate time scales in complex tissue microstructure limits the accurate quantification of extracellular diffusivity and tissue microstructure. We introduce TRACED, a biophysical model that incorporates diffusion time dependence in cell distributions to quantify pathologically-relevant properties in solid tumors. Neural networks were trained on Monte Carlo diffusion simulations using sphere distribution-based geometries to enable the rapid computation of time-dependent diffusion MRI signals in cell populations of variable cell size. Model sensitivity and fit performance were assessed via simulation. Diffusion data from eight mixed-grade glioma patients was fitted using the TRACED model. Data fitting was performed using a novel physics-informed transfer learning pipeline, Sim2PINN. In two patients, cell size measurements were compared directly with image-localized histology. Simulation results indicate improved parameter estimation compared to the simple two-compartment model. TRACED enabled the simultaneous in vivo quantification of intracellular volume fraction, cell size distribution, extracellular intrinsic diffusivity, and tortuosity in glioma patients. Neural network implementations of diffusion time-dependence and tortuosity showed behavior consistent with coarse-graining and effective medium theory, respectively. Future work will explore the clinical utility of TRACED parameters in additional patients.2026-05-04T14:03:48Z14 pages, 8 figures (main); 2 pages, 4 figures (supplementary). Submitted to Magnetic Resonance in MedicineJoshua K. MarchantHong-Hsi LeeElizabeth R. GerstnerSusie Y. HuangBruce R. Rosenhttp://arxiv.org/abs/2605.02605v1Mitigation of Boundary Sampling Artifacts in Phase Space Generation for Electron FLASH Radiotherapy2026-05-04T13:52:27ZApplicator-specific phase space (PHSP) files recorded at the aperture exit reduce Monte Carlo dose calculation time by 30-50% for electron FLASH radiotherapy. However, positioning PHSP scoring planes coincident with the applicator-air interface introduces boundary sampling artifacts. This study characterizes these artifacts in Geant4-based simulations and demonstrates their mitigation. PHSP files were generated using GAMOS 6.2.0 for a 9 MeV Mobetron UHDR model across twelve clinical aperture configurations (2.5-10 cm diameter). Three scoring plane positions were evaluated relative to the physical aperture exit: coincident with the interface, 0.1 mm downstream, and 1 mm downstream. Scoring at the exact interface produced proximal R50 shifts of up to 2.2 mm and Distance-to-Agreement (DTA) values of 4-6 mm, exceeding clinical acceptance criteria. Artifact severity scaled inversely with aperture diameter, with the smallest configurations most severely affected. A 0.1 mm offset partially restored the primary electron energy spectrum but failed to recover the bremsstrahlung tail. A 1 mm offset fully resolved all artifacts, achieving mean DTA values within 2.0 mm, equivalent to or better than linac-exit references. These artifacts arise from the degenerate behavior of the fUseSafety step-limitation algorithm when safety equals zero at exact material boundaries, producing incomplete secondary electron equilibration and suppressed bremsstrahlung production. Angular distribution analysis revealed a near-forward particle pileup in the 0 mm PHSP and a deficit of large-angle secondaries recovered by the 1 mm offset. A 1 mm downstream offset fully mitigates these artifacts while introducing negligible perturbation to primary beam characteristics. This requirement applies to any Geant4-based framework (including TOPAS and GATE) scoring PHSP files at material exit surfaces.2026-05-04T13:52:27Z14 pages, 8 figuresRafael CarballeiraThayer School of Engineering, Dartmouth College, Hanover, New HampshireRongxiao ZhangThayer School of Engineering, Dartmouth College, Hanover, New HampshireSchool of Medicine, University of Missouri, Columbia, MissouriKevin J. WillyThayer School of Engineering, Dartmouth College, Hanover, New HampshireHayley CashMedical University of South Carolina, Charleston, South CarolinaDavid J. GladstoneThayer School of Engineering, Dartmouth College, Hanover, New HampshireDartmouth Cancer Center, Lebanon, New Hampshirehttp://arxiv.org/abs/2604.16161v2VQ-Wave: A physics-driven spatio-temporal deep learning approach for non-contrast-enhanced lung ventilation and perfusion MRI2026-05-04T13:38:11ZPurpose: To develop a robust deep learning framework for non-contrast-enhanced functional lung MRI, overcoming the limitations of spectral decomposition in the presence of physiological non-stationarity.
Methods: We introduce VQ-Wave (Ventilation/Q-perfusion Waveform-based Assessment of Variable Evolutions), a physics-driven spatio-temporal inception neural network trained on synthetic signal models to estimate ventilation and perfusion parameters. By processing local spatial context alongside temporal evolution, the network learns to decouple physiological signals from noise. The training generator simulated non-stationary dynamics, including amplitude modulations, frequency drifts, and noise. Performance was validated against matrix pencil (MP) decomposition using numerical phantoms and in-vivo lung MRI acquired in four healthy volunteers and two children with cystic fibrosis (CF) at 1.5T.
Results: In numerical benchmarks, VQ-Wave demonstrated superior robustness to non-stationarity, maintaining low global and regional error rates where MP exhibited stochastic instability due to spectral leakage. In-vivo, VQ-Wave accurately captured functional defects in patients with CF yielding ventilation and perfusion maps with high quantitative stability (mean variation < 12%) even when scan time was reduced from 45s to 15s. Conversely, under irregular physiology and short scan lengths, MP decomposition severely degraded, exhibiting systematic amplitude instability, overestimation bias, and regional signal dropouts.
Conclusion: VQ-Wave offers a robust, physics-driven neural network-based alternative to spectral decomposition. By effectively handling physiological irregularity and noise, it enables reliable functional lung imaging with substantially shortened acquisition protocols.2026-04-17T15:30:38ZGrzegorz BaumanPavlos PanosPhilipp LatzinOliver Bieri10.1002/mrm.70423http://arxiv.org/abs/2605.01918v1Characterising Water Exchange in Gliomas Using Diffusion MRI with Free Gradient Waveforms2026-05-03T14:57:37ZTransmembrane water permeability, which regulates cellular water exchange and is influenced by water channels such as aquaporin-4 (AQP4), has been implicated in glioma progression and may affect tumour infiltration and treatment response. Non-invasive mapping of water exchange may therefore provide biomarkers of glioma pathology. This study investigates the feasibility of characterizing water exchange in gliomas using diffusion MRI with free gradient waveforms, known as the Restriction-Exchange (ResEx) approach, which enables exchange quantification independent of restricted diffusion effects. Thirteen patients with histologically confirmed gliomas (ten glioblastomas, three astrocytomas) underwent preoperative MRI at 3T using a custom ResEx protocol. Multiple diffusion-weighted acquisitions with selective exchange sensitivity were performed to estimate voxel-wise maps of the apparent diffusion coefficient (ADC), diffusion kurtosis, and water exchange rate. ResEx-derived maps revealed heterogeneous spatial patterns across and within tumours. Elevated exchange rates were commonly observed in enhancing tumour margins, potentially reflecting smaller cells, increased membrane permeability or AQP4 upregulation. In some cases, elevated exchange extended into non-enhancing peritumoural regions. Exchange values in oedema were slightly higher than in healthy tissue, suggesting potential infiltration or membrane disruption. Diffusion MRI with free gradient waveforms permits non-invasive mapping of water exchange in gliomas and reveals physiological information not captured by standard imaging. Exchange rate mapping may offer novel biomarkers of tumour aggressiveness, infiltration, and treatment response, and holds promise for surgical and radiotherapy planning.2026-05-03T14:57:37ZArthur ChakwiziraFilip SzczepankiewiczCarl-Fredrik WestinLinda KnutssonPia C SundgrenMarkus Nilssonhttp://arxiv.org/abs/2605.01629v1Brain criticality through nonadditive entropic analysis of electroencephalograms2026-05-02T22:40:43ZOn the grounds of nonadditive entropies -- appropriate for complex systems -- we investigate the electroencephalogram amplitudes of typical and ADHD children. The corresponding probability distributions are $q$-Gaussians, i.e., $ρ(x) \propto e_q^{-βx^2} \equiv [1+(q-1) βx^2]^{1/(1-q)}$, where $(q,β)$ are, respectively, the entropic index characterizing complexity and the inverse width. We show that $q$ tends to monotonically vary with $β$ for both typical and ADHD subjects, thus revealing critical behavior of the brain. Moreover, we verify that ADHD subjects have a higher complexity than the typical ones. Consistently, biomarkers for objective phychyatric diagnosis could emerge along this path. We show that $q$ tends to monotonically vary with $β$ for both typical and ADHD subjects, thus revealing critical behavior of the brain. Moreover, we verify that ADHD subjects have a higher complexity than the typical ones. Consistently, biomarkers for objective phychyatric diagnosis could emerge along this path.2026-05-02T22:40:43Z7 pages and 6 figuresHenrique Santos LimaConstantino TsallisDimitri M. Abramovhttp://arxiv.org/abs/2605.01265v1X-ray dark-field imaging from intensity flow: A Fokker-Planck approach to grating interferometry2026-05-02T05:48:04ZGrating interferometry is a promising diagnostic technique that enables simultaneous acquisition of three complementary, synergistic X-ray images: transmission, differential phase, and dark-field. Its key advantage over other setups is its ability to use large pixels and, hence, large-area detectors, as well as its compatibility with low-coherence, compact X-ray sources, both of which are key factors for human-scale imaging. It has already demonstrated strong potential for chest imaging applications, including the diagnosis of pulmonary emphysema, fibrosis, and cancer. To retrieve transmission, differential phase, and dark-field images from data, an algorithm is required to separate the distinct mechanisms contributing to measured contrast. Since its realization, this image-retrieval step has remained fundamentally unchanged. In this work, we develop a novel transmission- and dark-field retrieval algorithm for grating-interferometry derived from the X-ray Fokker-Planck equation. To demonstrate and validate our Fokker-Planck algorithm, we apply it to experimental measurements of a test sample and to data from a mouse chest acquired with varying exposure times and added Poisson noise. The retrieved images were qualitatively and quantitatively compared with those retrieved using a conventional sinusoidal-fitting approach. Across both samples, the Fokker--Planck method produced images consistent with conventional retrieval, with a comparable signal-to-noise ratio. Notably, our Fokker-Planck method suppresses artefacts arising in the conventional approach under grating perturbations (e.g., structural defects like scratches) and reduced flux or visibility, yielding smoother and more reproducible images. Additionally, we demonstrate that our Fokker-Planck method has an advantage over the conventional dark-field retrieval method for fast sample imaging with short exposure times and high noise.2026-05-02T05:48:04ZSupplementary material is available upon request from the corresponding author (samantha.alloo@monash.edu)Samantha J. AllooFlorian SchaffRegine GradlBenedikt GuntherFranz PfeifferKaye S. Morganhttp://arxiv.org/abs/2605.00730v1Reconstruction of glymphatic transport fields from subject-specific imaging data, with particular emphasis on cerebrospinal fluid flow and tracer conservation2026-05-01T15:29:16ZThe reconstruction of physically valid transport fields from subject-specific imaging data is a fundamental challenge in image-based computational modeling due to measurement noise, modeling uncertainties and discretization errors. Without a methodology to construct models that faithfully reflect the underlying physics, mechanistic understanding of complex biological systems is inherently limited. In this work, we address this challenge in the glymphatic system, the brain's waste-clearance network, where cerebrospinal fluid (CSF) is transported through perivascular spaces into the brain parenchyma to facilitate metabolic waste removal. We introduce a computational framework for the high-fidelity reconstruction of subject-specific glymphatic transport fields from spatiotemporal imaging data. The formulation utilizes an advection-diffusion model with a velocity decomposition that imposes mass conservation, enabling the recovery of solenoidal (divergence-free) velocity fields through the solution of a constrained inverse problem. The system is discretized using immersed isogeometric analysis with quadratic B-spline basis functions, providing smooth, high-continuity solutions and inherent regularization of imaging noise. We demonstrate the framework's utility by using contrast-enhanced magnetic resonance imaging of tracer transport in a mouse brain, obtaining spatially varying estimates of CSF velocity, diffusivity, and clearance parameters. Forward simulations using the recovered fields show close agreement with experimental observations, validating the framework's ability to characterize complex transport dynamics while preserving physical integrity. This approach provides a generalizable methodology for the robust inference of physically consistent transport fields from imperfect imaging data, with broad applicability to the image-guided modeling of biological and engineering systems.2026-05-01T15:29:16ZTotal 40 pages including references and appendix, 16 figuresA. Derya BakilerMichael J. JohnsonMichael R. A. AbdelmalikFrimpong A. BaidooAndrew BadachhapeAnanth V. AnnapragadaThomas J. R. HughesShaolie S. Hossainhttp://arxiv.org/abs/2605.00511v1Pre-CAT: A web-based, graphical user-interface toolbox for preclinical CEST-MRI data processing and analysis2026-05-01T08:38:43ZPurpose: As interest in CEST-MRI grows, particularly in the preclinical setting, the necessity for standardized and easy-to-use acquisition and data analysis pipelines has become apparent. While vendors have increasingly introduced support for CEST acquisitions on both clinical and preclinical hardware, image post-processing and analysis pipelines remain siloed based on privately developed code. We aim to develop an easy-to-use, open-source graphical user interface toolbox for preclinical CEST-MRI data analysis (Preclinical CEST-MRI Analysis Tool; Pre-CAT), supporting multiple acquisition types, organ systems, and CEST contrast mechanisms. Methods: Pre-CAT was developed in Python and utilizes the Numpy, Scipy, and Matplotlib libraries for data analysis and plotting. Inbuilt data processing steps include image loading, reconstruction, post-processing, and segmentation. Pre-CAT also supports data analysis for QUESP, CEST-MRF, and field mapping experiments using consensus protocols and methods. Pre-CAT's web interface and GUI were developed using Streamlit, an open-source Python framework. Pre-CAT is hosted and accessible online and can be downloaded for local installation to complete the data analysis pipeline in roughly one minute using modern hardware. Results: Pre-CAT analysis pipelines for Z-spectroscopy, CEST-MRF, and quantitative CEST (QUESP/QUEST) are demonstrated. Conclusion: With the introduction of Pre-CAT, we aim to standardize the preclinical CEST-MRI data analysis pipeline, fostering collaboration across research sites and reducing methodological redundancy. Pre-CAT is open-source and relatively modular, encouraging the addition of new methods and protocols.2026-05-01T08:38:43ZJonah Weigand-WhittierSamuel RubinCindy AyalaMark VelasquezNikita VladimirovHadas AvrahamOr PerlmanM. Roselle AbrahamMoriel H. Vandsburgerhttp://arxiv.org/abs/2512.04401v3Learnt Microwave Image Reconstruction with A Conformal Antenna Array2026-05-01T02:18:06ZA deep learning model is proposed for reconstructing 2D dielectric breast images from time-domain signals. Unlike existing learning models that employ a fixed antenna array, where input data consists solely of measurements, the proposed system integrates antenna positioning into the processing pipeline. This allows for a conformal antenna array that adapts to different breast sizes for optimal data collection across various patients, which eliminates undesired signal attenuation in coupling liquid when implemented for the fixed array. By leveraging antenna positions, the breast surface can be pre-estimated, enabling the neural network to focus on image reconstruction within the region of interest. Numerical results demonstrate that the proposed model may reconstruct breast images with good quality.2025-12-04T02:50:44Z10 pagesWenyi ShaoBeibei Zhou