https://arxiv.org/api/Dn8H9bkdTQwGLmjEZoLPSWKijJs2026-07-17T21:46:20Z90581515http://arxiv.org/abs/2607.10670v1Electrohydrodynamic wind generation in planar DBDs: role of electrode symmetry and geometry2026-07-12T09:31:29ZThis study experimentally and numerically investigates the electrohydrodynamic (EHD) interaction produced by a surface dielectric barrier discharge (SDBD) plasma actuator at atmospheric pressure. The non-thermal dielectric barrier discharge generates ionic wind, which is characterized using a symmetric annular actuator composed of concentric ring and disk electrodes. Unlike conventional linear SDBD actuators that primarily produce tangential airflow, this annular configuration generates a predominantly vertical ionic-wind jet. The effects of electrode diameter D and thickness delta on the induced wind velocity perpendicular to the electrode plane are systematically examined. The experimental results show a maximum wind velocity of 3.42 m s^{-1} for an optimized electrode configuration with D = 32 mm and delta = 0.06 mm. Numerical plasma-fluid simulations support the experimental trends and provide spatial distributions of airflow velocity, electrohydrodynamic volumetric force, electron temperature, and gas pressure in the plasma region. Additional diagnostics based on ozone concentration measurements and Schlieren imaging show that electrodes with larger diameters, particularly 22 and 32 mm, enhance the height and development of the vertical flow, while increasing electrode diameter also promotes ozone production. The results demonstrate an important trade-off between ionic-wind performance and reactive byproduct generation. These findings provide practical guidance for optimizing annular dielectric barrier discharge plasma actuators for active flow control, air purification, ozone-assisted disinfection, and biomedical plasma applications.2026-07-12T09:31:29Zpages, 18 figures, 3 tables. Experimental and numerical study of vertical ionic-wind generation by an annular surface dielectric barrier discharge plasma actuator. Includes COMSOL plasma-fluid simulations, Schlieren flow visualization, Pitot-tube velocity measurements, and ozone measurements. Published in Physica ScriptaPhysica Scripta 101 (2026) 065601Farshad SohbatzadehSaeed Ranjbar MalekshahHamed Soltani AhmadiS MirzanejhadRamin MehrabifardSamira MavaddatiZdenko Machala10.1088/1402-4896/ae3e22http://arxiv.org/abs/2606.13485v2Interaction Dynamics MPC for Knee Rehabilitation Exoskeletons: A Series-Elastic Instantiation2026-07-11T23:18:26ZSafe rehabilitation is an interaction-dynamics problem: the controller must regulate a prescribed motion while absorbing involuntary spasm, voluntary effort, actuator compliance, and model mismatch as interaction disturbances. This paper instantiates the predictive interaction-dynamics framework of the base pHRI formulation on a series-elastic-actuated knee joint. SEA feedforward reduces the gravity-compensated knee to the same constant-coefficient scalar double integrator used in the base framework, while a dynamic-residual measurement from spring deflection supplies an interaction-disturbance observation. A steady-state target converts the estimated disturbance into a cancelling input, and a finite-horizon quadratic program regulates deviations from that target under range-of-motion, torque, and velocity constraints. The evaluation is stiffness- and damping-matched so improvements cannot be attributed to higher impedance. Under a motion-opposing $15\unit{Nm}$ step, classical impedance and MPC without estimation produce about $500\unit{mrad}$ steady-state error, whereas Kalman-augmented interaction MPC reduces this to $1.17\unit{mrad}$ at 100~Hz and $0.70\unit{mrad}$ at 500~Hz; the 500~Hz peak is $7.27\unit{mrad}$. In 30 randomized trials, the 95th-percentile peak is $21.57\unit{mrad}$. Bounded Assist-as-Needed scheduling, a corrective-channel energy tank, inequality-constrained OSQP stress cases, direct MuJoCo execution, and a posture-clamped MyoSuite knee-slice run are implemented. The results support the SEA-knee instantiation of the interaction-dynamics framework while separating it from clinical intent recognition, full-system passivity, safety certification, hardware trials, and free-standing multi-joint validation.2026-06-11T15:35:03ZYongyan CaoJinshan Tanghttp://arxiv.org/abs/2505.18782v9Joint Reconstruction of Activity and Attenuation in PET by Diffusion Posterior Sampling in Wavelet Coefficient Space2026-07-11T15:57:46ZAttenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography (CT) or magnetic resonance (MR) scan. However, this additional scan may complicate the imaging workflow, introduce misalignment artifacts and increase radiation exposure. In this paper, we propose a joint reconstruction of activity and attenuation (JRAA) approach that eliminates the need for auxiliary anatomical imaging by relying solely on emission data. This framework combines wavelet diffusion model (WDM) and diffusion posterior sampling (DPS) to reconstruct fully three-dimensional (3-D) data. Experimental results on simulated data show our method outperforms maximum likelihood activity and attenuation (MLAA) and MLAA-UNet with U-Net-based post processing, and yields high-quality noise-free reconstructions across various count settings with time-of-flight (TOF). It is also able to reconstruct non-TOF data, although the reconstruction quality significantly degrades in low-count (LC) conditions, limiting its practical effectiveness in such settings. Nonetheless, a non-TOF Biograph mMR real data reconstruction with joint scatter estimation highlights the potential of the method for clinical applications. This approach represents a step towards stand-alone PET imaging by reducing the dependence on anatomical modalities while maintaining quantification accuracy, even in LC scenarios when TOF information is available. Our code is available on GitHub at https://github.com/clemphg/jraa-dps.2025-05-24T16:39:50Z16 pages, 10 figures, 8 tablesClémentine Phung-NgocAlexandre BousseAntoine De PaepeThibaut MerlinBaptiste LaurentHong-Phuong DangOlivier SautCatherine Cheze-Le-RestDimitris Visvikis10.1109/TRPMS.2026.3706239http://arxiv.org/abs/2607.10019v1Optically-powered Low Power Low Noise Amplifiers for MRI2026-07-10T22:44:48ZPurpose: Fully optical receive coils can potentially allow dense receiver arrays with a large channel count, reduced channel crosstalk, and less cable clutter. The power requirements of conventional low-noise amplifiers (LNAs) are prohibitive for simultaneously driving many coils through optical means, as opto-electric power conversion efficiencies can only reach about 50%. The goal is to develop low-power LNAs (LPLNA) with substantially lower power consumption without compromising noise figure (NF) and gain. Methods: A LPLNA was designed as a two-stage cascaded amplifier using an MR-compatible E-pHEMT (Enhancement-mode Pseudomorphic High Electron Mobility Transistor) transistor. The design was implemented on a single-sided printed circuit board (PCB), and its performance was compared with a commercial LNA. A four-channel shielded loop resonator array was constructed, and the signal-to-noise ratio (SNR), noise covariance, and preamplifier decoupling performance were evaluated. Results: The LPLNA had a five-fold lower electrical power consumption (40 mW) than the commercial LNA and provided comparable SNR in phantom measurements. In vivo experiments further confirmed that the LPLNA operates reliably under realistic MRI conditions. Additionally, four-channel receiver array measurements demonstrated comparable SNR within 2% of the commercial LNA and lower inter-channel noise correlation with 0.26 vs 0.3 on average. Conclusion: This study demonstrates the feasibility of LPLNAs for optically-powered RF receiver coil arrays. The LPLNA could also be applied in power-constrained or remote MRI environments.2026-07-10T22:44:48ZReza AghabagheriJakob GerlachZining LiuMorteza TeymooriCaglar AtamanMichael BockAli Caglar Oezenhttp://arxiv.org/abs/2511.11274v3Polarization-Sensitive Module for Optical Coherence Tomography Instruments2026-07-10T21:05:56ZPolarization-sensitive optical coherence tomography (PS-OCT) extends OCT by analyzing the polarization states of backscattered light to quantify tissue birefringence. However, conventional implementations require polarization-diverse detection and are therefore incompatible with most commercial OCT systems. As a result, PS-OCT has largely remained restricted to specialized research groups, limiting its broader scientific and clinical use. Here, we present a modular PS-OCT framework that integrates with a standard spectral-domain OCT platform through a detachable rotating achromatic half-wave plate in the sample arm. This waveplate modulates both incident and reflected polarization states. Three or more repeated measurements at distinct waveplate orientations enable reconstruction of the sample's round-trip Jones matrix and the corresponding polarization properties. To mitigate random phase variations between repeated measurements, we introduce a phase optimization strategy. We validate the framework with imaging of birefringent phantoms and the human retina in vivo, demonstrating reliable reconstruction of retardance and optic axis orientation. In this study, we implemented a polarization-sensitive module on the SPECTRALIS platform with minimal hardware modification. The framework could potentially be extended to other OCT systems with appropriate mechanical integration and access to acquisition data. By reducing the hardware complexity typically associated with conventional PS-OCT, this framework may facilitate broader adoption of PS-OCT imaging in both research and clinical settings.2025-11-14T13:09:37Z12 pages, 10 figuresPo-Yi LeeChuan-Bor ChuehMilen ShishkovSebastián Ruiz-LoperaTai-Ang WangHsiang-Chieh LeeTeresa ChenBrett E. BoumaMartin Villigerhttp://arxiv.org/abs/2607.09948v1Artificial Intelligence Across the Cardiac Amyloidosis Diagnostic Pathway: From Single-Modality Detection to Multimodal Clinical Integration2026-07-10T20:02:50ZCardiac amyloidosis (CA) is increasingly recognized but remains substantially underdiagnosed, because its clinical and imaging phenotype overlaps with more common cardiomyopathies. Definitive subtype assignment and management further require integration of multimodal evidence to distinguish transthyretin from light chain disease. Machine learning and deep learning have been applied across the diagnostic and management pathway. These applications span ECG, echocardiography, and health record-based case finding, as well as CMR and nuclear interpretation, including SPECT/CT biomarker quantification, prognostic modeling, and treatment response assessment. This narrative review synthesizes these studies by clinical tasks, namely screening, detection, quantification, prognosis, and treatment response monitoring, rather than by input modality. This task-based organization clarifies why apparently similar AI models require different cohorts, reference standards, evaluation metrics, and implementation thresholds. The evidence reveals a maturity gradient. Binary detection and AI assisted quantification on bone scintigraphy and SPECT/CT are closest to clinical translation. Detection is supported by large externally validated cohorts, and quantification by interpretable, outcome linked measurement of myocardial tracer burden. By contrast, subtype aware classification, prognostic risk stratification, and treatment response monitoring remain at an early stage. These tasks are limited by small cohorts, enriched retrospective designs, heterogeneous labels, incomplete external validation, and uncertain calibration in realistic prevalence settings. Across tasks, high discrimination alone is insufficient.2026-07-10T20:02:50ZDiana Shadibaeva and Rochak Dhakal contributed equally to this work. Total Pages = 35, No. of Figures = 4, No. of Tables on Manuscript = 1, Supplementary Tables = 6Diana ShadibaevaRochak DhakalKui ZhangXiaofeng YangSaurabh MalhotraWeihua Zhouhttp://arxiv.org/abs/2607.09945v1APHABAMAS: An analytical phantom-based scheme for assessing the accuracy of high-resolution 3D MRI motion-artifact simulations2026-07-10T19:55:56ZPurpose: Motion compromises the utility of high-resolution 3D MRI, an established tool in quantitative neuroimaging research. Deep learning-based methods have shown promise for mitigating motion-induced artifacts, but their development typically requires simulated motion-corrupted data. Several open-source tools exist for this task, each implementing different algorithms. However, no scheme currently exists for evaluating the accuracy of these simulations, making it difficult for users to choose the most suitable tool. Developing such a scheme is the aim of this study. Methods: The essential ingredient of the desired scheme is a ground-truth reference simulation that does not suffer from sampling-induced error. To meet this requirement, the proposed scheme, APHABAMAS, leverages a digital phantom whose representations in both the image and Fourier domains can be expressed analytically under arbitrary rigid-body transformations. Results: APHABAMAS is used to quantify the sampling-induced errors of three existing simulation algorithms, establishing their first definitive accuracy-based ranking. Conclusions: APHABAMAS provides a rigorous tool for assessing the accuracy of high-resolution 3D MRI motion-artifact simulations. It allows the accuracy-based ranking of existing simulation algorithms to be established, thereby enabling informed selection of the most suitable algorithm for synthesizing motion-corrupted data.2026-07-10T19:55:56ZTianqi WuHui Zhanghttp://arxiv.org/abs/2607.09401v1Two observables of one wall: how surface relaxivity can bias the diffusion intra-axonal fraction and the myelin water fraction2026-07-10T13:27:44ZSurface relaxivity and time-dependent diffusion are two readouts of the same wall collisions on one substrate: the transverse rate that microstructure imaging fits is a bulk rate plus a surface rate $ρ\,(S/V)$, and intra- and extra-axonal water carry different $S/V$, so their $T_2$ differ and any compartment estimate that normalises by a TE-weighted $b=0$ is biased. We derive closed forms for the interior (Brownstein-Tarr) and exterior (Novikov-Burcaw) surface rates over myelinated cylinders, validate them with wall-counting Monte Carlo, and quantify the resulting bias on the diffusion intra-axonal signal fraction $f_{\mathrm{intra}}$ and on the myelin water fraction (MWF). The interior/exterior $S/V$ ratio is $(1-\mathrm{VF})/(g\,\mathrm{VF})$, independent of the calibre distribution and crossing unity at fibre volume fraction $\mathrm{VF}^{\ast}=1/(1+g)$. Physiological white matter sits above this crossover, so surface relaxivity over-weights the intra-axonal signal, biasing $f_{\mathrm{intra}}$ by $\approx 12\%$ at clinical PGSE ($\mathrm{TE}=80\,\mathrm{ms}$). That fractions are TE-dependent is known; new here are the surface-relaxivity and packing attribution, a closed-form sign law, and a testable packing-dependent TE drift. The same physics reads through relaxometry as a smaller MWF bias: the thinnest axons' water crosses below the myelin window and is counted as myelin, so fine white matter reads myelin-richer ($\sim 0.33\,\mathrm{pp}$, beneath single-voxel noise but super-linear in the uncertain $ρ$), while in primary lumen-preserving demyelination this bias is nearly constant and cancels in the longitudinal change. One $S/V$ physics thus biases both diffusion and relaxometry microstructure estimates, the $f_{\mathrm{intra}}$ bias being first-order and packing-dependent, the MWF bias small and structural.2026-07-10T13:27:44ZRutger H. J. Fickhttp://arxiv.org/abs/2509.23136v2Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence2026-07-09T14:24:02ZPurpose: To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2*), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence and fat-water separation.
Theory and Methods: R1f and R1w were calculated with fat-specific and water-specific MP2RAGE signals. R2* and PDFF maps were obtained from fat-water separation applied to the second RAGE block. Sequence parameters optimization was performed via Cramér-Rao lower bounds theory, and we designed four protocols with different combinations of number of echoes and readout gradient schemes (I: 3 echoes unipolar, II: 6 echoes unipolar, III: 6 echoes bipolar, and IV: 10 echoes bipolar). We tested and validated these protocols with numerical simulations, phantom and in vivo experiments. In phantoms, we compared ME-MP2RAGE measurements with inversion recovery spin-echo (IR-SE) global R1 and 3D Fast Low Angle Shot (3D FLASH) R2* and PDFF. In vivo, we scanned the lower leg and neck of a healthy volunteer.
Results: Numerical simulations showed accurate quantification of relaxation rates with mean relative bias < 3% and PDFF with mean bias < 0.003 using protocol ME-MP2RAGE IV (10 echoes bipolar). Phantom experiments showed excellent agreement with IR-SE and 3D FLASH measurements. In vivo, measurements in the lower leg and neck were consistent with literature values.
Conclusion: We proposed an accurate method for simultaneous quantification of R1f, R1w, R2*, and PDFF from a single acquisition with the ME-MP2RAGE sequence.2025-09-27T05:39:08ZThe manuscript has 8 figures and 2 table. Additional tables and figures are presented in the Supplementary InformationJorge Campos PazmiñoMarc-Antoine FortinVéronique FortierEvan McNabbRenée-Claude BiderAndré van der KouweIves R. Levesquehttp://arxiv.org/abs/2605.30172v2A Lumped-Element Electrical Model of the Human Head for Brain-Oriented Applications2026-07-09T14:23:03ZIn this work, we present a compact surrogate circuit for electro-quasi-static (EQS) head modeling. A three-shell geometry (brain, skull, scalp) is considered, and each layer is modeled through radial and tangential pathways, implemented as RC branches. Frequency-dependent tissue conductivity and permittivity are mapped into dispersive resistive and capacitive elements. The model is validated against a semi-analytical spherical-harmonics reference solution over multiple geometrical configurations and operating frequencies, demonstrating good agreement. Neglecting dispersion and capacitive pathways can lead to an overestimation of scalp potentials over the considered frequency range, highlighting the need for dispersive RC circuit modeling.2026-05-28T16:21:51Z4 pages, 4 figures. To appear in the proceedings of the APS March Meeting 2026, Detroit, MichiganAngelo FacciaErmanno CitraroFrancesco P. Andriullihttp://arxiv.org/abs/2407.18709v3Immunity to Increasing Condition Numbers of Linear Superiorization versus Linear Programming2026-07-09T10:13:26ZGiven a family of linear constraints and a linear objective function one can consider whether to apply a Linear Programming (LP) algorithm or use a Linear Superiorization (LinSup) algorithm on this data. In the LP methodology one aims at finding an optimal point, i.e., a point that fulfills the constraints and has the minimal value of the objective function over these constraints. The Linear Superiorization approach considers the same data as in linear programming problems but instead of attempting to solve with linear programming methods it employs perturbation resilient feasibility-seeking algorithms that steer the iterations toward a feasible point with reduced (not necessarily minimal) objective function value. This aim of the superiorization method (SM) is less demanding than aiming to reach full-fledged constrained optimality and it places more importance on reaching feasibility than on reaching optimality. Previous studies (e.g., [1]) compared LP and LinSup in terms of their respective outputs and the resources they use. Here, we investigate classical LP approaches and LinSup in terms of their sensitivity to condition numbers of the system of linear constraints. Condition numbers are a measure for the impact of deviations in the input data on the output of a problem and, in particular, they describe the factor of error propagation when given wrong or erroneous data. Therefore, the ability of LP and LinSup to cope with increased condition numbers, thus with illposed problems, is an important matter to consider which was not studied until now. We investigate experimentally the advantages and disadvantages of both LP and LinSup on exemplary sets of data of problems of linear programming with multiple condition numbers and different problem dimensions.2024-07-26T12:49:52Z18 pages, 6 figuresJan SchröderYair CensorPhilipp SüssKarl-Heinz Küferhttp://arxiv.org/abs/2607.08084v1ConRad: Efficient Conformal Prediction for Radiomics2026-07-09T03:32:58ZRadiomic features derived from medical images and segmentation masks are used to support decision making in clinical imaging pipelines. In practice, these features are often computed from predicted masks, but segmentation models can be overconfident or poorly calibrated, making derived measurements appear more reliable than they are. Conformal prediction (CP) provides distribution-free prediction intervals with finite-sample marginal coverage guarantees, but black-box intervals for segmentation-derived radiomics can be inefficient because they ignore test-time information about image appearance, mask geometry, and segmentation uncertainty. We propose ConRad, a conformal framework for scalar radiomic targets that uses covariates derived from the predicted mask, input image, predicted radiomics, and boundary uncertainty to construct adaptive intervals while maintaining coverage. Across five 2D medical imaging datasets and 171 retained radiomic targets, we show that ConRad improves feature-level efficiency compared to baselines while maintaining near-nominal empirical coverage. Ablation results further indicate that segmentation boundary uncertainty features are the largest contributors to interval efficiency.2026-07-09T03:32:58ZCode available at https://github.com/matthewyccheung/conradMatt Y. CheungAshok VeeraraghavanGuha Balakrishnanhttp://arxiv.org/abs/2604.06482v2Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)2026-07-08T21:43:59ZTime-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.2026-04-07T21:34:54Z57 pages, 10 figuresJiacheng XieHua-Chieh ShaoCan WuRicardo OtazoJie DengMu-Han LinTsuicheng ChiuJacob BuattiViktor IakovenkoYou Zhanghttp://arxiv.org/abs/2607.07906v1Understanding quorum sensing self-organization: Clustering and defect-induced ordering of diffusing particles2026-07-08T20:42:21ZQuorum sensing (QS) is known in biology as a form of intercellular communication mediated by signaling molecules called autoinducers. The QS protocol governs the transition from individual to collective cell behavior once a critical population density is reached. Using numerical simulations, we investigate how defects influence the QS transition and the structural organization of the resulting colonies. Our model system consists of a mixture of slow ("cold") and fast ("hot") diffusing colloidal particles that obey the QS protocol, together with defect particles characterized by a constant diffusivity. A striking reentrant solidification of QS particles, characterized by long-range order, is induced by hot defects, whereas cold defects give rise to amorphous structures with only short-range order. These findings deepen our understanding of the QS interaction and provide a mechanism to control the degree of organization in QS systems, with potential applications in robotics, social sciences, and medicine -- for instance, in overcoming antimicrobial resistance.2026-07-08T20:42:21Z9 pages, 8 figures (first version submitted on May 14, 2026)Feifei LiuVyacheslav R. MiskoYunyun LiFabio Marchesonihttp://arxiv.org/abs/2607.07039v1From Data Completeness to Data Sufficiency: A Task-Driven Imaging Framework for Intraoperative CBCT under Quality-Time-Dose Trade-offs2026-07-08T06:16:30ZMobile C-arm cone-beam computed tomography (CBCT) has been widely used for real-time intraoperative 3D imaging. However, current practice often mechanically applies the fan-beam CT criterion of "180° plus fan angle" in pursuit of "data completeness" in reconstruction. This review argues that, under the single circular trajectory of three-dimensional cone-beam geometry, complete data are mathematically unattainable; moreover, blindly increasing sampling may exacerbate the trade-off among intraoperative image quality (Q), imaging time (T), and radiation dose (D). Against this background, this review reframes the evaluation of intraoperative CBCT around "data sufficiency" rather than "data completeness." This perspective moves beyond the excessive pursuit of absolute mathematical and analytic accuracy, and instead emphasizes task-specific minimum image-quality thresholds required for clinical decision-making. By synthesizing evidence from multiple clinical scenarios, this review suggests that approximation errors can be acceptable when clinical decision-making requirements are satisfied, thereby achieving a Q-T-D balance.2026-07-08T06:16:30ZYi JiaRongjun GeYang ChenYan XiWenjun Xia