https://arxiv.org/api/fV5OAnQ2Xo8UmPG0cZEovyQ1p1w 2026-06-27T16:18:38Z 9008 1485 15 http://arxiv.org/abs/2503.18342v1 Limited-angle SPECT image reconstruction using deep image prior 2025-03-24T05:02:09Z In SPECT image reconstruction, limited-angle (LA) conditions lead to a loss of frequency components, which distort the reconstructed tomographic image along directions corresponding to the non-collected projection angle range. Although conventional iterative image reconstruction methods have been used to improve the reconstructed images in LA conditions, the image quality is still unsuitable for clinical use. We propose a LA SPECT image reconstruction method that uses an end-to-end deep image prior (DIP) framework to improve reconstructed image quality. The proposed LA SPECT image reconstruction is an end-to-end DIP framework which incorporates a forward projection model into the loss function to optimise the neural network. By also incorporating a binary mask that indicates whether each data point in the measured projection data has been collected, the proposed method restores the non-collected projection data and reconstructs a less distorted image. The proposed method was evaluated using 20 numerical phantoms and clinical patient data. In numerical simulations, the proposed method outperformed existing back-projection-based methods in terms of PSNR and SSIM. We analysed the reconstructed tomographic images in the frequency domain using an object-specific modulation transfer function, in simulations and on clinical patient data, to evaluate the response of the reconstruction method to different frequencies of the object. The proposed method significantly improved the response to almost all spatial frequencies, even in the non-collected projection angle range. The results demonstrate that the proposed method reconstructs a less distorted tomographic image. The proposed end-to-end DIP-based reconstruction method restores lost frequency components and mitigates image distortion under LA conditions by incorporating a binary mask into the loss function. 2025-03-24T05:02:09Z Phys. Med. Biol. 70 (2025) 145005 Kensuke Hori Fumio Hashimoto Kazuya Koyama Takeyuki Hashimoto 10.1088/1361-6560/adea09 http://arxiv.org/abs/2503.18162v1 SNRAware: Improved Deep Learning MRI Denoising with SNR Unit Training and G-factor Map Augmentation 2025-03-23T18:16:36Z To develop and evaluate a new deep learning MR denoising method that leverages quantitative noise distribution information from the reconstruction process to improve denoising performance and generalization. This retrospective study trained 14 different transformer and convolutional models with two backbone architectures on a large dataset of 2,885,236 images from 96,605 cardiac retro-gated cine complex series acquired at 3T. The proposed training scheme, termed SNRAware, leverages knowledge of the MRI reconstruction process to improve denoising performance by simulating large, high quality, and diverse synthetic datasets, and providing quantitative information about the noise distribution to the model. In-distribution testing was performed on a hold-out dataset of 3000 samples with performance measured using PSNR and SSIM, with ablation comparison without the noise augmentation. Out-of-distribution tests were conducted on cardiac real-time cine, first-pass cardiac perfusion, and neuro and spine MRI, all acquired at 1.5T, to test model generalization across imaging sequences, dynamically changing contrast, different anatomies, and field strengths. The best model found in the in-distribution test generalized well to out-of-distribution samples, delivering 6.5x and 2.9x CNR improvement for real-time cine and perfusion imaging, respectively. Further, a model trained with 100% cardiac cine data generalized well to a T1 MPRAGE neuro 3D scan and T2 TSE spine MRI. 2025-03-23T18:16:36Z Hui Xue Sarah M. Hooper Iain Pierce Rhodri H. Davies John Stairs Joseph Naegele Adrienne E. Campbell-Washburn Charlotte Manisty James C. Moon Thomas A. Treibel Peter Kellman Michael S. Hansen http://arxiv.org/abs/2503.17930v1 Determination of unscaled blood input for human dynamic FDG brain PET 2025-03-23T04:09:45Z Objectives: Many existing techniques for the non-invasive quantification of the blood input function in dynamic FDG-PET imaging require strong historical information or user input. The technique proposed in this work utilizes the assumption that a dynamic PET scan can be modeled by the Patlak plot to determine an unscaled blood input function. Materials and Methods: The time activity curve (TAC) for each voxel in a dynamic image can be considered as an n-dimensional vector. In this context, a TAC follows the Patlak plot if and only if the TAC is a linear combination of the blood input function and the integral of the blood input function. Given a set of TACs which follow the Patlak plot, we can thus use PCA to determine a basis which spans the same vector space as the blood input function and the integral of the blood input function. We then seek to find two TACs in this vector space which best satisfy that the estimated anti-derivative of one of the TACs is close to the other TAC; such TACs are candidates for the blood input function and the integral of the blood input function. We were able to construct a low (2) dimensional optimization problem to find such TACs. Results: We applied our results to obtain predicted blood input functions and Ki maps for twelve normal subjects. Scaling the predicted blood input function to best match the ground truth, we achieved an average SSE of $0.042 \pm 0.032$ and an average DTW distance of $0.141 \pm 0.053$. Matching the means of the predicted and ground truth Ki maps, we achieved an average MAPE of $2.539 \pm 0.928$ and an average SSIM of $0.991 \pm 0.005$. Conclusion: While not often viewed as such, the assumption that some dynamic data follows a kinetic model gives strong prior information. In the case of the Patlak plot, we can use this assumption to estimate an unscaled blood input function and unscaled Ki map. 2025-03-23T04:09:45Z 20 pages, 10 figures, to be submitted to IEEE Transactions on Medical Imaging William Terrell Mark Muzi Bijoy Kundu http://arxiv.org/abs/2503.17553v1 Autonomous Radiotherapy Treatment Planning Using DOLA: A Privacy-Preserving, LLM-Based Optimization Agent 2025-03-21T22:01:19Z Radiotherapy treatment planning is a complex and time-intensive process, often impacted by inter-planner variability and subjective decision-making. To address these challenges, we introduce Dose Optimization Language Agent (DOLA), an autonomous large language model (LLM)-based agent designed for optimizing radiotherapy treatment plans while rigorously protecting patient privacy. DOLA integrates the LLaMa3.1 LLM directly with a commercial treatment planning system, utilizing chain-of-thought prompting, retrieval-augmented generation (RAG), and reinforcement learning (RL). Operating entirely within secure local infrastructure, this agent eliminates external data sharing. We evaluated DOLA using a retrospective cohort of 18 prostate cancer patients prescribed 60 Gy in 20 fractions, comparing model sizes (8 billion vs. 70 billion parameters) and optimization strategies (No-RAG, RAG, and RAG+RL) over 10 planning iterations. The 70B model demonstrated significantly improved performance, achieving approximately 16.4% higher final scores than the 8B model. The RAG approach outperformed the No-RAG baseline by 19.8%, and incorporating RL accelerated convergence, highlighting the synergy of retrieval-based memory and reinforcement learning. Optimal temperature hyperparameter analysis identified 0.4 as providing the best balance between exploration and exploitation. This proof of concept study represents the first successful deployment of locally hosted LLM agents for autonomous optimization of treatment plans within a commercial radiotherapy planning system. By extending human-machine interaction through interpretable natural language reasoning, DOLA offers a scalable and privacy-conscious framework, with significant potential for clinical implementation and workflow improvement. 2025-03-21T22:01:19Z 19 pages, 5 figures, preprint Humza Nusrat Department of Radiation Oncology, Henry Ford Health, Detroit, USA College of Human Medicine, Michigan State University, East Lansing, USA Bing Luo Department of Radiation Oncology, Henry Ford Health, Detroit, USA Ryan Hall Department of Radiation Oncology, Henry Ford Health, Detroit, USA Joshua Kim Department of Radiation Oncology, Henry Ford Health, Detroit, USA Hassan Bagher-Ebadian Department of Radiation Oncology, Henry Ford Health, Detroit, USA College of Human Medicine, Michigan State University, East Lansing, USA Anthony Doemer Department of Radiation Oncology, Henry Ford Health, Detroit, USA Benjamin Movsas Department of Radiation Oncology, Henry Ford Health, Detroit, USA College of Human Medicine, Michigan State University, East Lansing, USA Kundan Thind Department of Radiation Oncology, Henry Ford Health, Detroit, USA College of Human Medicine, Michigan State University, East Lansing, USA http://arxiv.org/abs/2403.10346v2 End-to-end Adaptive Dynamic Subsampling and Reconstruction for Cardiac MRI 2025-03-21T16:26:49Z $\textbf{Background:}$ Accelerating dynamic MRI is vital for advancing clinical applications and improving patient comfort. Commonly, deep learning (DL) methods for accelerated dynamic MRI reconstruction typically rely on uniformly applying non-adaptive predetermined or random subsampling patterns across all temporal frames of the dynamic acquisition. This approach fails to exploit temporal correlations or optimize subsampling on a case-by-case basis. $\textbf{Purpose:}$ To develop an end-to-end approach for adaptive dynamic MRI subsampling and reconstruction, capable of generating customized sampling patterns maximizing at the same time reconstruction quality. $\textbf{Methods:}$ We introduce the End-to-end Adaptive Dynamic Sampling and Reconstruction (E2E-ADS-Recon) for MRI framework, which integrates an adaptive dynamic sampler (ADS) that adapts the acquisition trajectory to each case for a given acceleration factor with a state-of-the-art dynamic reconstruction network, vSHARP, for reconstructing the adaptively sampled data into a dynamic image. The ADS can produce either frame-specific patterns or unified patterns applied to all temporal frames. E2E-ADS-Recon is evaluated under both frame-specific and unified 1D or 2D sampling settings, using dynamic cine cardiac MRI data and compared with vSHARP models employing standard subsampling trajectories, as well as pipelines where ADS was replaced by parameterized samplers optimized for dataset-specific schemes. $\textbf{Results:}$ E2E-ADS-Recon exhibited superior reconstruction quality, especially at high accelerations, in terms of standard quantitative metrics (SSIM, pSNR, NMSE). $\textbf{Conclusion:}$ The proposed framework improves reconstruction quality, highlighting the importance of case-specific subsampling optimization in dynamic MRI applications. 2024-03-15T14:31:35Z 38 pages, 26 figures, 2 tables George Yiasemis Jan-Jakob Sonke Jonas Teuwen http://arxiv.org/abs/2411.18249v2 Deep End-to-end Adaptive k-Space Sampling, Reconstruction, and Registration for Dynamic MRI 2025-03-21T14:54:33Z Dynamic MRI enables a range of clinical applications, including cardiac function assessment, organ motion tracking, and radiotherapy guidance. However, fully sampling the dynamic k-space data is often infeasible due to time constraints and physiological motion such as respiratory and cardiac motion. This necessitates undersampling, which degrades the quality of reconstructed images. Poor image quality not only hinders visualization but also impairs the estimation of deformation fields, crucial for registering dynamic (moving) images to a static reference image. This registration enables tasks such as motion correction, treatment planning, and quantitative analysis in applications like cardiac imaging and MR-guided radiotherapy. To overcome the challenges posed by undersampling and motion, we introduce an end-to-end deep learning (DL) framework that integrates adaptive dynamic k-space sampling, reconstruction, and registration. Our approach begins with a DL-based adaptive sampling strategy, optimizing dynamic k-space acquisition to capture the most relevant data for each specific case. This is followed by a DL-based reconstruction module that produces images optimized for accurate deformation field estimation from the undersampled moving data. Finally, a registration module estimates the deformation fields aligning the reconstructed dynamic images with a static reference. The proposed framework is independent of specific reconstruction and registration modules allowing for plug-and-play integration of these components. The entire framework is jointly trained using a combination of supervised and unsupervised loss functions, enabling end-to-end optimization for improved performance across all components. Through controlled experiments and ablation studies, we validate each component, demonstrating that each choice contributes to robust motion estimation from undersampled dynamic data. 2024-11-27T11:38:48Z 48 pages, 23 figures, 8 tables George Yiasemis Jan-Jakob Sonke Jonas Teuwen http://arxiv.org/abs/2501.17954v2 Discrete Dielectric Coatings for Length Control and Tunability of Half-Wave Dipole Antennas at 300 MHz Magnetic Resonance Imaging Applications 2025-03-21T14:32:48Z This study presents a novel discretely dielectric material-coated (DDMC) dipole antenna design for ultra-high-field (UHF) MRI applications. This design improves frequency tuning, lowers electric field intensity, and reduces SAR by including discrete high-permittivity dielectric coatings at both ends of the dipole. The DDMC dipole's performance was compared to that of a fractionated dipole design using metrics such as inter-element coupling, B1 field distribution, and SNR. Simulations and experimental results showed that the DDMC dipole provided superior B1 field uniformity with significantly reduced B1 variation along the dipole conductor while reducing SAR, making it a safer and more efficient option for MR signal excitation and reception in UHF MR imaging. Furthermore, with its improved electromagnetic decoupling performance, the multichannel array made from the proposed DDMC dipoles shows promise for improving parallel imaging and imaging quality in UHF MRI, with future work focusing on material optimization and scalability for multi-channel arrays. 2025-01-29T19:30:09Z 9 pages, 10 figures Aditya A Bhosale Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States Yunkun Zhao Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States Divya Gawande Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States Komlan Payne Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States Xiaoliang Zhang Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, NY, United States http://arxiv.org/abs/2503.16918v1 Design of 3D Non-Cartesian Trajectories for Fast Volumetric MRI via Analytic Coordinate Discretization 2025-03-21T07:31:55Z 3D non-Cartesian trajectories offer several advantages over rectilinear trajectories for rapid volumetric imaging, including improved sampling efficiency and greater robustness to motion, flow, and aliasing artifacts. In this paper, we present a unified framework for designing three widely used non-Cartesian trajectories: 3D Radial, 3D Cones, and Stack-of-Spirals. Our approach is based on the idea that a non-Cartesian trajectory can be interpreted as a discretized version of an analytic coordinate defined by a set of template trajectories. Equivalently, the analytic coordinate is conceptualized as a non-Cartesian trajectory composed of an infinite number of copies of a set of template trajectories. The discretization is accomplished by constructing a continuous spiral path on a surface and sampling points along this path at unit intervals, leaving only the essential spokes/interleaves, thereby yielding the practical non-Cartesian trajectory from the analytic coordinate. One of the advantages of our approach is that the analytic density compensation factor can be readily derived using Jacobian determinants, which quantify changes in unit areas due to the transformation from the analytic coordinate to the Cartesian grid. Additionally, the proposed approach derives analytic formulae to compute the number of readouts based on prescribed parameters, allowing us to specify the trajectory's acceleration factor for a given total scan time. Furthermore, variable-density sampling can be easily incorporated, and spokes/interleaves are smoothly distributed in k-space along the derived spiral path, even for a small number of readouts. In a preliminary phantom study, the proposed method demonstrated improved sampling efficiency and image quality compared to the conventional approach. 2025-03-21T07:31:55Z preprint, 11 pages, 8 figures Kwang Eun Jang Dwight G. Nishimura http://arxiv.org/abs/2503.16706v1 ISIT-GEN: An in silico imaging trial to assess the inter-scanner generalizability of CTLESS for myocardial perfusion SPECT on defect-detection task 2025-03-20T20:58:07Z A recently proposed scatter-window and deep learning-based attenuation compensation (AC) method for myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), namely CTLESS, demonstrated promising performance on the clinical task of myocardial perfusion defect detection with retrospective data acquired on SPECT scanners from a single vendor. For clinical translation of CTLESS, it is important to assess the generalizability of CTLESS across different SPECT scanners. For this purpose, we conducted a virtual imaging trial, titled in silico imaging trial to assess generalizability (ISIT-GEN). ISIT-GEN assessed the generalizability of CTLESS on the cardiac perfusion defect detection task across SPECT scanners from three different vendors. The performance of CTLESS was compared with a standard-of-care CT-based AC (CTAC) method and a no-attenuation compensation (NAC) method using an anthropomorphic model observer. We observed that CTLESS had receiver operating characteristic (ROC) curves and area under the ROC curves similar to those of CTAC. Further, CTLESS was observed to significantly outperform the NAC method across three scanners. These results are suggestive of the inter-scanner generalizability of CTLESS and motivate further clinical evaluations. The study also highlights the value of using in silico imaging trials to assess the generalizability of deep learning-based AC methods feasibly and rigorously. 2025-03-20T20:58:07Z Zitong Yu Nu Ri Choi Zezhang Yang Nancy A. Obuchowski Barry A. Siegel Abhinav K. Jha http://arxiv.org/abs/2503.16170v1 Advancing Tumor Budding Detection with Fourier Ptychography Microscopy 2025-03-20T14:11:03Z Background: Tumour budding is an independent predictor of metastasis and prognosis in colorectal cancer and is a vital part of the pathology specification report. In a conventional pathological section observation process, pathologists have to repeatedly switch from 10x objective to 20x objective several times to localize and image the target region. Besides the switching operations, repeated manual or electro-mechanical focusing is also very time-consuming, affecting the total time for pathological diagnosis. In addition, It is usually necessary to remove the manually marked symbols on the stained pathology slides used for classification and management before observation. Methods: In this paper, we utilize Fourier ptychographic microscopy (FPM) in the pathological diagnosis process to realize large space-bandwidth product imaging, quantitative phase imaging, and digital refocusing in the observation process without any mechanical operations, which can therefore simplify the above-mentioned cumbersome diagnostic processes. We first verify the effectiveness and efficiency of the proposed method with several typical pathological sections. Then, instead of manually erasing, we also prove that FP framework can digitally remove the artificial markers with its digital refocusing ability. Results: At last, we demonstrated pathologists can achieve 100% diagnostic accuracy with FPM imaging results. Conclusions: The proposed method can greatly simplify the process of pathological diagnosis, and the related addon hardware system does not require expensive components, which makes it have great potential for promotion in the field of pathological diagnosis. 2025-03-20T14:11:03Z Yiyan Su Ruiqing Sun Yajing Wang Yanfeng xi Shaohui Zhang http://arxiv.org/abs/2503.15708v1 Sustainable Deep Learning-Based Breast Lesion Segmentation: Impact of Breast Region Segmentation on Performance 2025-03-19T21:42:33Z Purpose: Segmentation of the breast lesion in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is an essential step to accurately diagnose and plan treatment and monitor progress. This study aims to highlight the impact of breast region segmentation (BRS) on deep learning-based breast lesion segmentation (BLS) in breast DCE-MRI. Methods Using the Stavanger Dataset containing primarily 59 DCE-MRI scans and UNet++ as deep learning models, four different process were conducted to compare effect of BRS on BLS. These four approaches included the whole volume without BRS and with BRS, BRS with the selected lesion slices and lastly optimal volume with BRS. Preprocessing methods like augmentation and oversampling were used to enhance the small dataset, data shape uniformity and improve model performance. Optimal volume size were investigated by a precise process to ensure that all lesions existed in slices. To evaluate the model, a hybrid loss function including dice, focal and cross entropy along with 5-fold cross validation method were used and lastly a test dataset which was randomly split used to evaluate the model performance on unseen data for each of four mentioned approaches. Results Results demonstrate that using BRS considerably improved model performance and validation. Significant improvement in last approach -- optimal volume with BRS -- compared to the approach without BRS counting around 50 percent demonstrating how effective BRS has been in BLS. Moreover, huge improvement in energy consumption, decreasing up to 450 percent, introduces a green solution toward a more environmentally sustainable approach for future work on large dataset. 2025-03-19T21:42:33Z Sam Narimani Solveig Roth Hoff Kathinka Dahli Kurz Kjell-Inge Gjesdal Jurgen Geisler Endre Grovik http://arxiv.org/abs/2503.15700v1 Impact of pH and chloride content on the biodegradation of magnesium alloys for medical implants: An in vitro and phase-field study 2025-03-19T21:22:57Z The individual contributions of pH and chloride concentration to the corrosion kinetics of bioabsorbable magnesium (Mg) alloys remain unresolved despite their significant roles as driving factors in Mg corrosion. This study demonstrates and quantifies hitherto unknown separate effects of pH and chloride content on the corrosion of Mg alloys pertinent to biomedical implant applications. The experimental setup designed for this purpose enables the quantification of the dependence of corrosion on pH and chloride concentration. The in vitro tests conclusively demonstrate that variations in chloride concentration, relevant to biomedical applications, have a negligible effect on corrosion kinetics. The findings identify pH as a critical factor in the corrosion of bioabsorbable Mg alloys. A variationally consistent phase-field model is developed for assessing the degradation of Mg alloys in biological fluids. The model accurately predicts the corrosion performance of Mg alloys observed during the experiments, including their dependence on pH and chloride concentration. The capability of the framework to account for mechano-chemical effects during corrosion is demonstrated in practical orthopaedic applications considering bioabsorbable Mg alloy implants for bone fracture fixation and porous scaffolds for bone tissue engineering. The strategy has the potential to assess the in vitro and in vivo service life of bioabsorbable Mg-based biomedical devices. 2025-03-19T21:22:57Z S. Kovacevic W. Ali T. K. Mandal E. Martínez-Pañeda J. Llorca http://arxiv.org/abs/2503.15691v1 Critical review of patient outcome study in head and neck cancer radiotherapy 2025-03-19T21:01:33Z Rapid technological advances in radiation therapy have significantly improved dose delivery and tumor control for head and neck cancers. However, treatment-related toxicities caused by high-dose exposure to critical structures remain a significant clinical challenge, underscoring the need for accurate prediction of clinical outcomes-encompassing both tumor control and adverse events (AEs). This review critically evaluates the evolution of data-driven approaches in predicting patient outcomes in head and neck cancer patients treated with radiation therapy, from traditional dose-volume constraints to cutting-edge artificial intelligence (AI) and causal inference framework. The integration of linear energy transfer in patient outcomes study, which has uncovered critical mechanisms behind unexpected toxicity, was also introduced for proton therapy. Three transformative methodological advances are reviewed: radiomics, AI-based algorithms, and causal inference frameworks. While radiomics has enabled quantitative characterization of medical images, AI models have demonstrated superior capability than traditional models. However, the field faces significant challenges in translating statistical correlations from real-world data into interventional clinical insights. We highlight that how causal inference methods can bridge this gap by providing a rigorous framework for identifying treatment effects. Looking ahead, we envision that combining these complementary approaches, especially the interventional prediction models, will enable more personalized treatment strategies, ultimately improving both tumor control and quality of life for head and neck cancer patients treated with radiation therapy. 2025-03-19T21:01:33Z Jingyuan Chen Yunze Yang Chenbin Liu Hongying Feng Jason M. Holmes Lian Zhang Steven J. Frank Charles B. Simone Daniel J. Ma Samir H. Patel Wei Liu http://arxiv.org/abs/2503.15663v1 Implantable CMOS probes for high resolution Electrical Imaging of Local Field Potentials Across the Rat Barrel Cortex in vivo 2025-03-19T19:28:37Z High-resolution recordings of extracellular potentials are fundamental for the study of neuronal networks, the basis of neuronal coding and transmission. Here we present an innovative method for an in vivo electrical imaging of Local Field Potentials using novel implantable neural interfaces with a high-density array of 256 recording sites and a spatial resolution of 15 μm. Thanks to this technology, we analyze the propagation of whisker-evoked activity in a single barrel-column of the rat somatosensory cortex. 2025-03-19T19:28:37Z 14 Pages, 7 Figures, 1 Table, to be submitted soon to Nature Materials or equivalent Claudia Cecchetto Mufti Mahmud Vincenzo Sorrenti Marta Maschietto Enrico Chiarello Mathias Schulz Roland Thewes Stefano Vassanelli http://arxiv.org/abs/2503.15153v1 Improving PET scanner time-of-flight resolution using additional prompt photon 2025-03-19T12:17:40Z Positronium Imaging requires two classes of events: double-coincidences originated from pair of back-to-back annihilation photons and triple-coincidences comprised with two annihilation photons and one additional prompt photon. The standard reconstruction of the emission position along the line-of-response of triple-coincidence event is the same as in the case of double-coincidence event; an information introduced by the high-energetic prompt photon is ignored. In this study, we propose to extend the reconstruction of position of triple-coincidence event by taking into account the time and position of prompt photon. We incorporate the knowledge about the positronium lifetime distribution and discuss the limitations of the method based on the simulation data. We highlight that the uncertainty of the estimate provided by prompt photon alone is much higher than the standard deviation estimated based on two annihilation photons. We finally demonstrate the extent of resolution improvement that can be obtained when estimated using three photons. 2025-03-19T12:17:40Z 17 pages, 9 figures, based on the content presented at WMLQ2024, accepted in Computer Science Journal Computer Science 26(SI) 2025 Lech Raczynski Wojciech Krzemien Konrad Klimaszewski 10.7494/csci.2025.26.SI.7057