https://arxiv.org/api/m/kvvnPSghNNAokOGgaATaAC8cY2026-06-27T15:16:32Z9008147015http://arxiv.org/abs/2503.22392v1Volumetric Material Decomposition Using Spectral Diffusion Posterior Sampling with a Compressed Polychromatic Forward Model2025-03-28T12:52:59ZWe have previously introduced Spectral Diffusion Posterior Sampling (Spectral DPS) as a framework for accurate one-step material decomposition by integrating analytic spectral system models with priors learned from large datasets. This work extends the 2D Spectral DPS algorithm to 3D by addressing potentially limiting large-memory requirements with a pre-trained 2D diffusion model for slice-by-slice processing and a compressed polychromatic forward model to ensure accurate physical modeling. Simulation studies demonstrate that the proposed memory-efficient 3D Spectral DPS enables material decomposition of clinically significant volume sizes. Quantitative analysis reveals that Spectral DPS outperforms other deep-learning algorithms, such as InceptNet and conditional DDPM in contrast quantification, inter-slice continuity, and resolution preservation. This study establishes a foundation for advancing one-step material decomposition in volumetric spectral CT.2025-03-28T12:52:59ZXiao JiangGrace J. GangJ. Webster Staymanhttp://arxiv.org/abs/2504.01025v1Diagnosis of Pulmonary Hypertension by Integrating Multimodal Data with a Hybrid Graph Convolutional and Transformer Network2025-03-28T01:14:17ZEarly and accurate diagnosis of pulmonary hypertension (PH) is essential for optimal patient management. Differentiating between pre-capillary and post-capillary PH is critical for guiding treatment decisions. This study develops and validates a deep learning-based diagnostic model for PH, designed to classify patients as non-PH, pre-capillary PH, or post-capillary PH. This retrospective study analyzed data from 204 patients (112 with pre-capillary PH, 32 with post-capillary PH, and 60 non-PH controls) at the First Affiliated Hospital of Nanjing Medical University. Diagnoses were confirmed through right heart catheterization. We selected 6 samples from each category for the test set (18 samples, 10%), with the remaining 186 samples used for the training set. This process was repeated 35 times for testing. This paper proposes a deep learning model that combines Graph convolutional networks (GCN), Convolutional neural networks (CNN), and Transformers. The model was developed to process multimodal data, including short-axis (SAX) sequences, four-chamber (4CH) sequences, and clinical parameters. Our model achieved a performance of Area under the receiver operating characteristic curve (AUC) = 0.81 +- 0.06(standard deviation) and Accuracy (ACC) = 0.73 +- 0.06 on the test set. The discriminative abilities were as follows: non-PH subjects (AUC = 0.74 +- 0.11), pre-capillary PH (AUC = 0.86 +- 0.06), and post-capillary PH (AUC = 0.83 +- 0.10). It has the potential to support clinical decision-making by effectively integrating multimodal data to assist physicians in making accurate and timely diagnoses.2025-03-28T01:14:17Z23 pages, 8 figures, 4 tablesFubao ZhuYang ZhangGengmin LiangJiaofen NanYanting LiChuang HanDanyang SunZhiguo WangChen ZhaoWenxuan ZhouJian HeYi XuIokfai CheangXu ZhuYanli ZhouWeihua Zhouhttp://arxiv.org/abs/2503.21384v1In vivo dynamic optical coherence tomography of human skin with hardware- and software-based motion correction2025-03-27T11:33:09ZIn vivo application of dynamic optical coherence tomography (DOCT) is hindered by bulk motion of the sample. We demonstrate DOCT imaging of \invivo human skin by adopting a sample-fixation attachment to suppress bulk motion and a subsequent software motion correction to further reduce the effect of sample motion. The performance of the motion-correction method was assessed by DOCT image observation, statistical analysis of the mean DOCT values, and subjective image grading. Both the mean DOCT value analysis and subjective grading showed statistically significant improvement of the DOCT image quality. In addition, a previously unobserved high DOCT layer was identified though image observation, which may represent the stratum basale with high keratinocyte proliferation.2025-03-27T11:33:09ZBiomed. Opt. Express 17, 1442-1461 (2026)Yu GuoRion MorishitaIbrahim Abd El-SadekKohei YamazakiShingo SakaiPradipta MukherjeeYiheng LimCunyou BaoKeiichi SugataShinya KasamatsuHiroyuki YoshidaShuichi MakitaYoshiaki Yasuno\10.1364/BOE.588691http://arxiv.org/abs/2407.12991v2Concrete and Lead Shielding Requirements for PET Facilities2025-03-27T08:47:31ZWe investigate shielding thickness requirements in concrete and lead walls for positron emission tomography (PET) facilities. F\textsuperscript{18}, the most commonly used PET radiotracer, emits two back-to-back 511 keV photons, necessitating effective shielding to protect hospital staff while patients are in treatment rooms and during their hospital stay. Photon transmission measurements were conducted through a standard Israeli B30 concrete wall (3 m high, 20 cm thick) using photons from an F\textsuperscript{18} source. A narrow-beam transmission coefficient of \( T = (3.0 \pm 1.0)\% \) was recorded with the source positioned 0.05 m from the wall, and the detector at distances of 0.05--3.0 m on the opposite side. When the source is 3 meters from the wall, photons within a 0.64 m radius circular disk (wide-beam) strike the wall. This produces a dose ``buildup'' effect, whereby photons striking within the disk reach the dosimeter after Compton scattering within the wall. The wide-beam transmission coefficient was measured as \( T = (8.8 \pm 1.8)\% \), corresponding to a buildup factor \( B = 4.0 \pm 0.8 \), consistent with Monte Carlo (MC) simulations \( B = 3.9 \pm 0.6 \), validating the simulation reliability for this specific setup. Note however that reliance solely on thick concrete walls presents construction challenges due to weight, space, and cost inefficiency. Since ordinary concrete effectively interacts only through Compton scattering, while lead walls interact via the photoelectric effect, lead is preferable for shielding. A 3.3 cm lead wall results in \( < 0.5\% \) transmission, and lead sheets can be supported by a 5 cm gypsum wall, optimizing shielding design. However, considering the environmental toxicity of lead, note that recent studies advocate the use of tungsten carbide.2024-07-17T20:16:53Z11 pages, 4 figures, 2tablesVictor SteinerAviv MalkiTzafrir Ben YehudaMurray Moinesterhttp://arxiv.org/abs/2401.10389v3Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data2025-03-26T20:31:19ZTranscranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of microbubble signals. We propose to use the \textit{a priori} knowledge of the medium based upon microbubble localization and wave propagation to build a forward model to link the measured signals directly to the aberration function. A standard least-squares inversion is then used to retrieve the aberration function. We first validated IPAC on simulated data of a vascular network using plane wave as well as divergent wave emissions. We then evaluated the reproducibility of IPAC \textit{in vivo} in 5 mouse brains. We showed that aberration correction improved the contrast of CEUS images by 4.6 dB. For ULM images, IPAC yielded sharper vessels, reduced vessel duplications, and improved the resolution from 21.1 $μ$m to 18.3 $μ$m. Aberration correction also improved hemodynamic quantification for velocity magnitude and flow direction.2024-01-18T21:58:44ZTransactions on Biomedical Engineering, vol. 72, no. 11, pp. 3196-3209, Nov. 2025Paul XingAntoine MalescotEric MartineauRavi RungtaJean Provost10.1109/TBME.2025.3564473http://arxiv.org/abs/2406.13078v3A universal bioluminescence tomography system for pre-clinical image-guided radiotherapy research2025-03-26T20:05:59ZCBCT-guided small animal irradiators encounter challenges in localizing soft-tissue targets due to low imaging contrast. Bioluminescence tomography (BLT) offers a promising solution, but they have largely remained in laboratorial development, limiting accessibility for researchers. In this work, we develop a universal, commercial-graded BLT-guided system (MuriGlo) designed to seamlessly integrate with commercial irradiators and empower researchers for translational studies. We demonstrate its capabilities in supporting in vitro and in vivo studies. The MuriGlo comprises detachable mouse bed, thermostatic control, mirrors, filters, and CCD, enabling multi-projection and multi-spectral imaging. We evaluate that the thermostatic control effectively sustains animal temperature at 37°C throughout imaging, and quantify that the system can detect as few as 61 GL261-AkaLuc cells in vitro. To illustrate how the MuriGlo can be utilized for in vivo image-guided research, we present 3 strategies, BLT-guided 5-arc, 2-field box, and BLI-guided single-beam, ranging from complicated high-conformal to simplest high-throughput plans. The high conformal BLT-guided 5-arc plan fully covers the gross tumor volume (GTV) at prescribed dose with minimal normal tissue exposure (3.9%), while the simplified, high-throughput BLT-guided 2-field box achieves 100% GTV coverage but results in higher normal tissue exposure (13.1%). Moreover, we demonstrate that the localization accuracy of MuriGlo for both widely-used SARRP and SmART irradiators is within1 mm, and the tumor coverage reaches over 97% with 0.75mm margin. The universal BLT-guided system offers seamless integration with commercial irradiators, achieving comparable localization accuracy, expected to supporting high-precision radiation research.2024-06-18T21:57:12ZZhishen TongZijian DengXiangkun XuCiara NewmanXun JiaYuncheng ZhongMerle ReinhartPaul TsouchlosTim DevlingHamid DehghaniIulian IordachitaDebabrata SahaJames KimJohn W. WongKen Kang-Hsin Wanghttp://arxiv.org/abs/2503.20946v1Nanophotonic thermal management in X-ray tubes2025-03-26T19:32:08ZIn X-ray tubes, more than 99% of the kilowatts of power supplied to generate X-rays via bremsstrahlung are lost in the form of heat generation in the anode. Therefore, thermal management is a critical barrier to the development of more powerful X-ray tubes with higher brightness and spatial coherence, which are needed to translate imaging modalities such as phase-contrast imaging to the clinic. In rotating anode X-ray tubes, the most common design, thermal radiation is a bottleneck that prevents efficient cooling of the anode$\unicode{x2014}$the hottest part of the device by far. We predict that nanophotonically patterning the anode of an X-ray tube enhances heat dissipation via thermal radiation, enabling it to operate at higher powers without increasing in temperature. The focal spot size, which is related to the spatial coherence of generated X-rays, can also be made smaller at a constant temperature. A major advantage of our "nanophotonic thermal management" approach is that in principle, it allows for complete control over the spectrum and direction of thermal radiation, which can lead to optimal thermal routing and improved performance.2025-03-26T19:32:08ZMain text: 13 pages including references, 2 figures; Supporting Information: 20 pages, 14 figures, located after the main text and referencesSimo PajovicCharles Roques-CarmesSeou ChoiSteven E. KooiRajiv GuptaMichael E. ZalisIvan ČelanovićMarin Soljačićhttp://arxiv.org/abs/2503.20751v1The Role of Computational Modeling in Enhancing Thermal Safety During Cardiac Ablation2025-03-26T17:36:24ZObjective: In this review, we aim to provide an analysis of current cardiac ablation techniques, such as radiofrequency ablation (RF), cryoablation, and pulsed-field ablation (PFA), with a focus on the role of computational modeling in enhancing the precision, safety, and effectiveness of these treatments. Particular attention is given to thermal management, exploring how computational approaches contribute to understanding and controlling energy delivery, heat distribution, and tissue response during ablation procedures. Methods: The mechanisms, applications, and limitations of radiofrequency (RF) ablation, cryoablation, and pulsed field ablation (PFA) are reviewed. Additionally, the use of computational approaches, including numerical methods and artificial intelligence (AI)-based models, for evaluating energy distribution, lesion size, and tissue response during ablation procedures is discussed. Results: Computational methods can predict ablation treatment outcomes and help optimize lesion size, ablation parameters, and procedural safety. However, these models are only reliable when properly validated and verified. Conclusion: Further research is essential to collect reliable in vivo data for validating computational models and integrating them into clinical practice to improve patient outcomes.2025-03-26T17:36:24ZThe Manuscript was submitted for review to ICVTS Journal, 40 pages, 1 figure, and 3 tables. Fateme Esmailie is the corresponding author. Leila Seidabadi and Indra Vandenbussche are Co-first authorsLeila SeidabadiIndra VandenbusscheRowan Carter FinkMacKenzie MooreBailey McCorkendaleFateme Esmailiehttp://arxiv.org/abs/2110.09841v3Cutting Voxel Projector a New Approach to Construct 3D Cone Beam CT Operator2025-03-26T12:51:33ZWe introduce a novel class of projectors for 3D cone beam tomographic reconstruction. Analytical formulas are derived to compute the relationship between the volume of a voxel projected onto a detector pixel and its contribution to the line integral of attenuation recorded by that pixel. Based on these formulas, we construct a near-exact projector and backprojector, particularly suited for algebraic reconstruction techniques and hierarchical reconstruction approaches with nonuniform voxel grids. Unlike traditional projectors, which assume a uniform grid with fixed voxel sizes, our method enables local refinement of voxels, allowing for adaptive grid resolution and improved reconstruction quality in regions of interest. We have implemented this cutting voxel projector along with a relaxed, speed-optimized version and compared them to two established projectors: a ray-tracing projector based on Siddon's algorithm and a TT footprint projector. Our results demonstrate that the cutting voxel projector achieves higher accuracy than the TT projector, especially for large cone beam angles. Furthermore, the relaxed version of the cutting voxel projector offers a significant speed advantage, while maintaining comparable accuracy. In contrast, Siddon's algorithm, tuned to achieve the same accuracy, is considerably slower than the cutting voxel projector. All algorithms are implemented in a GPU optimized open-source framework for algebraic reconstruction. GitHub repository of the project https://github.com/kulvait/KCT_cbct.2021-10-19T10:54:01Z12 pages, 5 figuresJournal of Computational Science, Vol. 87, No. 102573, 2025Vojtěch KulvaitInstitute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, GermanyJulian MoosmannInstitute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, GermanyGeorg RoseInstitute for Medical Engineering and Research Campus STIMULATE, University of Magdeburg, Magdeburg, Germany10.1016/j.jocs.2025.102573http://arxiv.org/abs/2402.09428v3Neural-network based high-speed volumetric dynamic optical coherence tomography2025-03-26T11:03:41ZWedemonstratedeep-learningneuralnetwork(NN)-baseddynamicopticalcoherence tomography (DOCT), which generates high-quality logarithmic-intensity-variance (LIV) DOCT images from only four OCT frames. The NN model is trained for tumor spheroid samples using a customized loss function: the weighted mean absolute error. This loss function enables highly accurate LIV image generation. The fidelity of the generated LIV images to the ground truth LIV images generated using 32 OCT frames is examined via subjective image observation and statistical analysis of image-based metrics. Fast volumetric DOCT imaging with an acquisition time of 6.55 s/volume is demonstrated using this NN-based method.2024-01-24T10:41:41ZBiomedical Optics Express 15(5), 3216-3239 (2024)Yusong LiuIbrahim Abd El-SadekRion MorishitaShuichi MakitaTomoko MoriAtsuko FurukawaSatoshi MatsusakaYoshiaki Yasuno10.1364/BOE.519964http://arxiv.org/abs/2503.20073v1Differential metabolic and cellular brain regional susceptibility in adult rats with chronic liver disease2025-03-25T21:18:32ZBackground & Aims: Patients with type C hepatic encephalopathy (HE) present diverse symptoms indicating that various brain regions are affected. Understanding the distinct metabolic and cellular changes across these regions could help explain the clinical variability of HE. We analyzed, for the first time, the longitudinal in-vivo neurometabolic and morphological changes in astrocytes, neurons and microglia in the hippocampus, striatum and cerebellum during the progression of CLD-induced type C HE in the bile duct ligated (BDL) rat model. Methods: Wistar rats underwent BDL and their brains were studied before BDL and at post-operative weeks-2, 4, 6 and 8 using in-vivo 1H-MRS (9.4T) of the hippocampus, striatum and cerebellum along with histological assessment (astrocytes, microglia, and neurons) and blood biochemistry. Results: Across all brain regions, glutamine (Gln) was the first metabolite to increase, followed by a decrease in osmolytes and neurotransmitters. The cerebellum was characterized by the highest Gln burden (+134%), elevated Lactate (+84%) and decreased GABA (-23%), suggesting its increased vulnerability. This coincided with pronounced alterations in astrocyte morphology, possibly related to the high Gln load. In contrast, the striatum displayed the lowest Gln increase (+48%) but the strongest osmolyte decrease, with milder astrocytic changes. We also showed mutual and distinct regional morphological changes in microglia (activation) and neurons (decreased dendritic spine density, soma size alterations). Conclusions: Our findings highlight both common and differential metabolic and cellular responses to CLD across the brain regions, with cerebellum and striatum showing differential responses. We also hypothesized that glutamine is one of the initial brain metabolic markers of type C HE, impacting astrocytes and inevitably neurons contributing to cognitive decline.2025-03-25T21:18:32ZDunja SimicicKatarzyna PierzchalaOlivier BraissantDario SessaValérie A. McLinCristina Cudalbuhttp://arxiv.org/abs/2503.19747v1Cystic Lung Phantom to Validate Clinical CT Protocols2025-03-25T15:11:02ZIn CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.2025-03-25T15:11:02ZShefra ShahFarah HussainiDumitru MaziluEric E. BennettHan Wenhttp://arxiv.org/abs/2503.19243v1Tumor monitoring and detection of lymph node metastasis using quantitative ultrasound and immune cytokine profiling in dogs undergoing radiation therapy: a pilot study2025-03-25T01:03:13ZQuantitative ultrasound (QUS) characterizes the composition of cells to distinguish diseased from healthy tissue. QUS can reflect the complexity of the tumor and detect early lymph node (LN) metastasis ex vivo. The objective in this study was to gather preliminary QUS and cytokine data from dogs undergoing radiation therapy and correlate QUS data with both LN metastasis and tumor response. Spontaneous solid tumors were evaluated with QUS before and up to one year after receiving RT. Additionally, regional LNs were evaluated with QUS in vivo, then excised and examined with histopathology to detect metastasis. Paired t-tests were used to compare QUS data of metastatic and non-metastatic LNs within patients. Furthermore, paired t-tests compared pre- versus post-RT QUS data. Serum was collected at each time point for cytokine profiles. Most statistical tests were underpowered to produce significant $p$ values, but interesting trends were observed. The lowest $p$ values for LN tests were found with the envelope statistics $K$ ($p = 0.142$) and $μ$ ($p = 0.181$), which correspond to cell structure and number of scatterers. For tumor response, the lowest $p$ values were found with $K$ ($p = 0.115$) and $μ$ ($p = 0.127$) when comparing baseline QUS data with QUS data 1 week after RT. Monocyte chemoattractant protein 1 (MCP-1) was significantly higher in dogs with cancer when compared to healthy controls ($p = 1.12$e-4). A weak correlation was found between effective scatterer diameter (ESD) and Transforming growth factor beta 1 (TGF$β$-1). While statistical tests on the preliminary QUS data alone were underpowered to detect significant differences among groups, our methods create a basis for future studies.2025-03-25T01:03:13Z8 pages, 5 figuresMick GardnerAudrey BillhymerRebecca KamererJoanna SchmitTrevor ParkJulie Nguyen-EdquilangRita MillerKim A SeltingMichael Oelzehttp://arxiv.org/abs/2503.18592v1The Role of Artificial Intelligence in Enhancing Insulin Recommendations and Therapy Outcomes2025-03-24T11:50:14ZThe growing worldwide incidence of diabetes requires more effective approaches for managing blood glucose levels. Insulin delivery systems have advanced significantly, with artificial intelligence (AI) playing a key role in improving their precision and adaptability. AI algorithms, particularly those based on reinforcement learning, allow for personalised insulin dosing by continuously adapting to an individual's responses. Despite these advancements, challenges such as data privacy, algorithm transparency, and accessibility still need to be addressed. Continued progress and validation in AI-driven insulin delivery systems promise to improve therapy outcomes further, offering people more effective and individualised management of their diabetes. This paper presents an overview of current strategies, key challenges, and future directions.2025-03-24T11:50:14ZMaria PanagiotouKnut StroemmenLorenzo BrigatoBastiaan E. de GalanStavroula Mougiakakouhttp://arxiv.org/abs/2503.18537v1In-vivo real-time 13C-MRSI without polarizer on site: across cities transportable hyperpolarization using UV-induced labile radicals2025-03-24T10:45:02ZHyperpolarized 13C Magnetic Resonance Spectroscopic Imaging (HP 13C-MRSI) has the potential to greatly improve diagnostic radiology thanks to its unique capability to detect, noninvasively, a wide range of diseases entailing aberrant metabolism. Nevertheless, it struggles to enter everyday clinical practice as an alternative and/or complement to Positron Emission Tomography (PET). Because of the minute-long hyperpolarization lifetime of the MR HP contrast agents, one of the reasons is, differently from PET, the need and financial burden to have the polarizing machine on site and, as close as possible to the MR scanner. In this work, we show that dDNP samples prepared with UV-induced labile radicals can bridge the technical gap with PET and provide MRI facilities with hours-long relaxing HP contrast agents. As a demonstration, we show the first across cities HP 13C-MRSI experiment in vivo and on a clinical scanner for a perfusion/angiography ([1-13C]HP001) and a metabolic ([U-13C, d7]glucose) contrast agent.2025-03-24T10:45:02ZAndrea CapozziMagnus KarlssonYupeng ZhaoJan KilundEsben Sovso Szocska HansenLotte Bonde BertelsenChristoffer LaustsenJan Henrik Ardenkjaer-LarsenMathilde H. Lerche