https://arxiv.org/api/Pc7b/1zP5V2nXv0P7YfRgmsPcGE 2026-06-27T14:04:07Z 9008 1455 15 http://arxiv.org/abs/2504.02748v1 Atrial constitutive neural networks 2025-04-03T16:35:49Z This work presents a novel approach for characterizing the mechanical behavior of atrial tissue using constitutive neural networks. Based on experimental biaxial tensile test data of healthy human atria, we automatically discover the most appropriate constitutive material model, thereby overcoming the limitations of traditional, pre-defined models. This approach offers a new perspective on modeling atrial mechanics and is a significant step towards improved simulation and prediction of cardiac health. 2025-04-03T16:35:49Z Mathias Peirlinck Kevin Linka Ellen Kuhl http://arxiv.org/abs/2504.02711v1 Anisotropy analysis of bamboo and tooth using 4-angle polarization micro-spectroscopy 2025-04-03T15:51:43Z To investigate the anisotropic properties of biomaterials, two distinct classes are considered: polymer-based (e.g., cellulose in plants) and crystalline-based (e.g., enamel in teeth), each demonstrating distinct structural and functional characteristics. Four-angle polarization (4-pol.) spectral mapping of sub-1 μm bamboo slices was carried out in the mid-IR spectral range (2.5-20 μm) to reveal the 3D organization of the chemical bonding of cellulose using the key characteristic absorption bands associated with C-O-C and C-N vibrational modes. The longitudinal and transverse microtome slices revealed a switch between the presence and absence of dichroism in parenchyma cell walls and vascular bundles. The cell wall showed continuous alignment of the C-O-C stretching vibrational mode (8.6 μm/1163 cm-1) down to the pixel resolution of ~ 4 μm (the step size in imaging) in the transverse slice; the cell wall thickness is ~ 1 μm. Thin microtomed slices of a tooth were measured in transmission and reflection modes. The single-point reflection measurements, performed using two perpendicular orientations, revealed orientational anisotropy in the enamel, which was absent in the dentin region. High sub-diffraction limited lateral resolution was numerically validated using a simplified-model of a Gaussian beam reading out material pixels with a defined orientation of absorption. It is shown that the orientation of small ~ λ/10 ~ 1 μm objects can be revealed using a focal spot of ~ λ/NA ~ 20 μm, defining the diffraction limit for the objective lens with a numerical aperture NA ~ 0.5. 2025-04-03T15:51:43Z 12 pages, 7 figures (+1 figure in supplement) Meguya Ryu Hsin-Hui Huang Jitraporn Vongsvivut Soon Hock Ng Irma Dumbryte Donatas Narbutis Mangirdas Malinauskas Saulius Juodkazis Junko Morikawa http://arxiv.org/abs/2409.14898v4 First image-guided treatment of a mouse tumor with radioactive ion beams 2025-04-01T19:23:49Z Radioactive ion beams (RIB) are a key focus of current research in nuclear physics. Already long ago it was proposed that they could have applications in cancer therapy. In fact, while charged particle therapy is potentially the most effective radiotherapy technique available, it is highly susceptible to uncertainties in the beam range. RIB are well-suited for image-guided particle therapy, as isotopes that undergo \b{eta}+-decay can be precisely visualized using positron emission tomography (PET), enabling accurate real-time monitoring of the beam range. We successfully treated a mouse osteosarcoma using a radioactive 11C-ion beam. The tumor was located in the neck, in close proximity to the spinal cord, increasing the risk of radiation-induced myelopathy from even slight variations in the beam range caused by anatomical changes or incorrect calibration of the planning CT. We managed to completely control the tumor with the highest dose while minimizing toxicity. Low-grade neurological side effects were correlated to the positron activity measured in the spine. The biological washout of the activity from the tumor volume was dependent on the dose, indicating a potential component of vascular damage at high doses. This experiment marks the first instance of tumor treatment using RIB and paves the way for future clinical applications. 2024-09-23T10:48:01Z 56 pages, 13 figures, supplements. Video supplements available on request Daria Boscolo Giulio Lovatti Olga Sokol Tamara Vitacchio Francesco Evangelista Emma Haettner Walter Tinganelli Christian Graeff Uli Weber Christoph Schuy Munetaka Nitta Martina Moglioni Daria Kostyleva Sivaji Purushothaman Peter G. Thirolf Jonathan Bortfeldt Christoph Scheidenberger Katia Parodi Marco Durante 10.1038/s41567-025-02993-8 http://arxiv.org/abs/2503.20407v2 Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise 2025-04-01T03:20:18Z Dynamic optical coherence tomography (DOCT) enables label-free functional imaging by capturing temporal OCT signal variations caused by intracellular and intratissue motions. However, the relationship between DOCT signals and the sample motion behind them remains unclear. This paper presents a comprehensive DOCT simulation framework that incorporates mathematical models of intracellular/intratissue motions, two OCT signal generator types that generate OCT signal time sequences from the moving scatterer models, and representative DOCT algorithms. The theory and algorithms of the framework are described in detail, and the utility of this framework is demonstrated through numerical studies. This framework is available as open source and will enhance the understanding and utility of DOCT. 2025-03-26T10:31:16Z Biomed. Opt. Express 16, 2875-2897 (2025) Yuanke Feng Shumpei Fujimura Yiheng Lim Thitiya Seesan Rion Morishita Ibrahim Abd El-Sadek Pradipta Mukherjee Shuichi Makita Yoshiaki Yasuno 10.1364/BOE.564025 http://arxiv.org/abs/2503.24195v1 Computational Orthodontic Force Simulation: A Review 2025-03-31T15:13:36Z In orthodontic treatment, the biological response of the tooth, periodontal ligament, and bone complex to orthodontic force is crucial in influencing treatment outcomes. The challenge lies in accurately measuring, estimating, and predicting these forces during clinical procedures. This review aims to fill the gap in the literature by systematically summarizing existing research on orthodontic force simulation, examining common loading techniques and technologies, and discussing the potential for refining the orthodontic force simulation process. The literature was comprehensively reviewed, with an emphasis on the exploration of the biological mechanism of tooth movement. Studies were categorized based on force-loading techniques for both fixed and invisible orthodontic appliances. Finite element (FE) analysis stands out as the predominant technique for orthodontic force simulation, with a significant focus on fixed orthodontics but limited emphasis on invisible orthodontics. Current orthodontic force simulations tend to be fragmented, often considering only the instantaneous response to applied forces. There exists an urgent demand for a sophisticated analytical simulation model. Such a model, possibly leveraging advanced technologies like deep learning, holds the promise of forecasting orthodontic treatment outcomes with heightened precision and efficiency. 2025-03-31T15:13:36Z 19 pages, 4 figure, 1 table Waheed Ahmad Jing Xiong Zeyang Xia http://arxiv.org/abs/2503.24158v1 Current status of real-time imaging of antiproton annihilation in biological targets 2025-03-31T14:42:01Z Following a successful pioneering study of the biological effects of antimatter ( the AD-4/ACE experiment at CERN), the use of antiprotons in clinical radiotherapy became a very serious possibility. A major part of any future radiotherapy using antiprotons will be real-time imaging of antiproton annihilation in biological targets. In principle, real-time imaging is possible thanks to the secondary particles, neutral pions and charger pions, produced by the annihilation of antiprotons in the cells they come to a stop in.Neutral pions decay dominantly and almost instantaneously into a photon pair, and one approach to real-time imaging is based on the detection of these high-energy gammas. An alternative is based on the detection of charged pions, which have lifetimes almost a billion times longer than neutral pions. This paper is a brief review of this field of research, from the first real-time imaging achieved by the AD-4/ACE experiment in 2004 to the present day. 2025-03-31T14:42:01Z 7 pages, 3 figures Zlatko Dimcovski Michael Doser http://arxiv.org/abs/2504.03728v1 When More Is Less: Higher Magnetic Fields and Their Limited Impact on SNR per Time Unit of Acquisition Time in Single Voxel Spectroscopy 2025-03-31T14:24:57Z Magnetic resonance spectroscopy (MRS) offers significant diagnostic potential but is inherently constrained by low signal-to-noise ratio (SNR). While increasing the main magnetic field strength B_0 is theoretically linked to increased SNR, practically obtained gains in SNR from B07/4 to B0 depending on the domination of thermal noise at high B0, are not always realized. Especially in clinical settings the maximum reachable SNR is further constrained by the total available acquisition time (TA) and the regulatory limits on maximum tolerable specific absorption rate (SAR). This work attempts to derive mathematical expressions that enable systematical analysis of the theoretical achievable SNR-gain. One important notion is this context is the SNR gain per unit of measurement time as a function of the main magnetic field B0 strengths in the case of single voxel spectroscopy (SVS) pulse sequences. Our findings indicate that under given fixed total amount of (patient acceptable) measurement time TA, and maximum tolerable SAR limitation, together with conditions that ensure the adiabaticity of specific sequences, further increasing B0 does not further improve SNR per unit of measurement time. Key factors were identified, including RF-pulse bandwidth scaling with B0 and longitudinal relaxation time (T1) dependencies, impact the net gain as well. Our theoretical analysis emphasizes critical considerations for optimizing SNR per unit time in clinical MRS, even challenging the presumption that higher magnetic fields B0 always yield improved SNR per time unit of measurement time performance. 2025-03-31T14:24:57Z Guodong Weng Johannes Slotboom http://arxiv.org/abs/2410.08856v3 FlowMRI-Net: A Generalizable Self-Supervised 4D Flow MRI Reconstruction network 2025-03-31T14:07:13Z Background: Image reconstruction from highly undersampled 4D flow MRI data can be very time consuming and may result in significant underestimation of velocities depending on regularization, thereby limiting the applicability of the method. The objective of the present work was to develop a generalizable self-supervised deep learning-based framework for fast and accurate reconstruction of highly undersampled 4D flow MRI and to demonstrate the utility of the framework for aortic and cerebrovascular applications. Methods: The proposed deep-learning-based framework, called FlowMRI-Net, employs physics-driven unrolled optimization using a complex-valued convolutional recurrent neural network and is trained in a self-supervised manner. The generalizability of the framework is evaluated using aortic and cerebrovascular 4D flow MRI acquisitions acquired on systems from two different vendors for various undersampling factors (R=8,16,24) and compared to state-of-the-art compressed sensing (CS-LLR) and deep learning-based (FlowVN) reconstructions. Evaluation includes an ablation study and a qualitative and quantitative analysis of image and velocity magnitudes. Results: FlowMRI-Net outperforms CS-LLR and FlowVN for aortic 4D flow MRI reconstruction, resulting in significantly lower vectorial normalized root mean square error and mean directional errors for velocities in the thoracic aorta. Furthermore, the feasibility of FlowMRI-Net's generalizability is demonstrated for cerebrovascular 4D flow MRI reconstruction, where no FlowVN can be trained due to the lack of high-quality reference data. Reconstruction times ranged from 3 to 7 minutes on commodity CPU/GPU hardware. Conclusion: FlowMRI-Net enables fast and accurate reconstruction of highly undersampled aortic and cerebrovascular 4D flow MRI, with possible applications to other vascular territories. 2024-10-11T14:35:52Z Luuk Jacobs Marco Piccirelli Valery Vishnevskiy Sebastian Kozerke http://arxiv.org/abs/2503.22578v2 Deducing Cardiorespiratory Motion of Cardiac Substructures Using a Novel 5D-MRI Workflow for Radiotherapy 2025-03-31T03:00:09Z Objective: Cardiotoxicity is a devastating complication of thoracic radiotherapy. Current radiotherapy imaging protocols are insufficient to decouple and quantify cardiac motion, limiting substructure-specific motion considerations in treatment planning. We propose a 5D-MRI workflow for substructure-specific motion analysis, with future extension to margin calculation. Approach: Our 5D-MRI workflow was implemented for 10 healthy volunteers, ranging from 23 to 65 years old, reconstructing images for end-exhale/inhale and active-exhale/inhale for end-systole/diastole. For motion assessment, proximal coronary arteries, chambers, great vessels, and cardiac valves/nodes were contoured across all images and verified. Centroid/bounding box excursion was calculated for cardiac, respiratory, and hysteresis motion. Distance metrics were tested for statistical independence across substructure pairings. Main Results: 5D-MRI images were successfully acquired and contoured for all volunteers. Cardiac motion was greatest for the coronary arteries (specifically the right coronary) and smallest for the great vessels. Respiratory motion was dominant in the S-I direction and largest for the inferior vena cava. Respiratory hysteresis was generally <5 mm but exceeded 5 mm for some volunteers. For cardiac motion, there were statistical differences between the coronary arteries, chambers, and great vessels, and between the right/left heart. Respiratory motion differed significantly between the base and apex of the heart. Significance: Our 5D-MRI workflow successfully decouples cardiorespiratory motion with one ~5-minute acquisition. Cardiac motion was >5mm for the coronary arteries and chambers, while respiratory motion was >5mm for all substructures. Statistical considerations and inter-patient variability indicate a substructure and patient-specific approach may be needed for PRV assessment. 2025-03-28T16:27:04Z Chase Ruff Tarun Naren Oliver Wieben Prashant Nagpal Kevin Johnson Jiwei Zhao Thomas Grist Carri Glide-Hurst http://arxiv.org/abs/2503.23528v1 Construction and characterisation of a coded-mask gamma camera for beam range monitoring in proton therapy 2025-03-30T17:17:15Z The major advantage of proton therapy over conventional radiotherapy is the dose deposition pattern, enabling precise coverage of the tumour volume while sparing nearby healthy tissues. However, accurate control of the proton beam range online during patient irradiation is still considered a challenge. Thus, there are extensive efforts to develop a detector capable of in vivo beam range monitoring for proton therapy, among them, the coded-mask gamma camera developed by the SiFi-CC group. The assembly of this detector, as well as its first test under clinical conditions, are the subject of this thesis. The detector consists of a tungsten collimator and a stack of thin scintillation fibres, read out at both ends by SiPMs. Such a design allows for efficient detection of prompt gammas (PG) and reconstruction of a PG depth profile, which is strongly correlated with the proton beam range. The readout system was selected in an extensive comparison study of five different systems. After assembly, the detector was tested under clinical conditions: a phantom was irradiated with proton beams of energies from 70.51 MeV to 108.15 MeV, the detector response was processed with low-level reconstruction software, and the MLEM algorithm was applied to reconstruct the PG depth profiles (images). The distal falloff positions of these profiles were determined and compared with the calculated proton ranges. The image reconstruction parameters were optimised in terms of accuracy of proton range shift determination. The results obtained were checked against a Geant4 simulation, showing good consistency. The statistical precision was found to be 1.7 mm for $10^8$ protons. The result is comparable to similar systems investigated by other research groups. However, simulation results suggest that certain hardware amendments to the detector can increase that precision about four times. 2025-03-30T17:17:15Z PhD Thesis Magdalena Kołodziej http://arxiv.org/abs/2503.23507v1 Federated Self-Supervised Learning for One-Shot Cross-Modal and Cross-Imaging Technique Segmentation 2025-03-30T16:40:12Z Decentralized federated learning enables learning of data representations from multiple sources without compromising the privacy of the clients. In applications like medical image segmentation, where obtaining a large annotated dataset from a single source is a distressing problem, federated self-supervised learning can provide some solace. In this work, we push the limits further by exploring a federated self-supervised one-shot segmentation task representing a more data-scarce scenario. We adopt a pre-existing self-supervised few-shot segmentation framework CoWPro and adapt it to the federated learning scenario. To the best of our knowledge, this work is the first to attempt a self-supervised few-shot segmentation task in the federated learning domain. Moreover, we consider the clients to be constituted of data from different modalities and imaging techniques like MR or CT, which makes the problem even harder. Additionally, we reinforce and improve the baseline CoWPro method using a fused dice loss which shows considerable improvement in performance over the baseline CoWPro. Finally, we evaluate this novel framework on a completely unseen held-out part of the local client dataset. We observe that the proposed framework can achieve performance at par or better than the FedAvg version of the CoWPro framework on the held-out validation dataset. 2025-03-30T16:40:12Z Siladittya Manna Suresh Das Sayantari Ghosh Saumik Bhattacharya http://arxiv.org/abs/2503.23161v1 Anthropomorphic tissue-mimicking phantoms for oximetry validation in multispectral optical imaging 2025-03-29T17:34:04Z Significance: Optical imaging of blood oxygenation (sO$_2$) can be achieved based on the differential absorption spectra of oxy- and deoxy-haemoglobin. A key challenge in realising clinical validation of the sO$_2$ biomarkers is the absence of reliable sO$_2$ reference standards, including test objects. Aim: To enable quantitative testing of multispectral imaging methods for assessment of sO$_2$ by introducing anthropomorphic phantoms with appropriate tissue-mimicking optical properties. Approach: We used the stable copolymer-in-oil base material to create physical anthropomorphic structures and optimised dyes to mimic the optical absorption of blood across a wide spectral range. Using 3D-printed phantom moulds generated from a magnetic resonance image of a human forearm, we moulded the material into an anthropomorphic shape. Using both reflectance hyperspectral imaging (HSI) and photoacoustic tomography (PAT), we acquired images of the forearm phantoms and evaluated the performance of linear spectral unmixing (LSU). Results: Based on 10 fabricated forearm phantoms with vessel-like structures featuring five distinct sO$_2$ levels (between 0 and 100%), we showed that the measured absorption spectra of the material correlated well with HSI and PAT data with a Pearson correlation coefficient consistently above 0.8. Further, the application of LSU enabled a quantification of the mean absolute error in sO$_2$ assessment with HSI and PAT. Conclusion: Our anthropomorphic tissue-mimicking phantoms hold potential to provide a robust tool for developing, standardising, and validating optical imaging of sO$_2$. 2025-03-29T17:34:04Z Kris Kristoffer Dreher Janek Groehl Friso Grace Leonardo A. Ayala Jan-Hinrich Nölke Christoph J Bender Melissa J Watt Catherine-Louise White Ran Tao Wibke Johnen Minu Dietlinde Tizabi Alexander Seitel Lena Maier-Hein Sarah Elizabeth Bohndiek http://arxiv.org/abs/2503.23148v1 Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections 2025-03-29T17:08:34Z X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina. 2025-03-29T17:08:34Z Hunter C. Meyer Conner B. Dooley Victoria L. Fontenot Kyungmin Ham Leslie G. Butler Alexandra Noel Joyoni Dey http://arxiv.org/abs/2503.22911v1 Development of a Miniaturized, Automated, and Cost-Effective Device for Enzyme-Linked Immunosorbent Assay 2025-03-28T23:26:45Z In this work, a miniaturized, automated, and cost-effective ELISA device is designed and implemented, without the utilization of conventional techniques such as pipetting or microfluidic valve technologies. The device has dimensions of 24 cm x 19 cm x 14 cm and weighs <3 Kg. The total hardware cost of the device is estimated to be approximately $1,200, which can be further reduced through optimization during scale-up production. 3D printed disposable parts, including the reagent reservoir disk and the microfluidic connector, have also been developed. IL-6 is used as a model system to demonstrate how the device provides an ELISA measurement. The cost per test is estimated to be less than ten dollars. The compactness, automated operation, along with the cost-effectiveness of this ELISA device, makes it suitable for point-of-care applications in resource-limited regions. 2025-03-28T23:26:45Z references in page 12, before tables and figures Majid Aalizadeh Shuo Yang Suchithra Guntur Vaishnavi Potluri Girish Kulkarni Xudong Fan http://arxiv.org/abs/2503.22438v1 Automatic determination of the different control mechanisms in upright position by a wavelet method 2025-03-28T13:57:54Z A recent model to analyze the Center of Pressure trajectories is based on the fractional Brownian motion. By doing so, one note that standing still is describe by different mechanisms following the frequency. Previous studies exhibit the existence of a control mechanism which stabilize the upright position at a large enough time scales (from 0.3 s to 1.2 s depending on the method and on the authors) or equivalently at low frequencies. The different mechanisms are separated by a critical time scale or equivalently a critical frequency. This critical frequency is fundamental to understand the control mechanism of upright position : only physiological phenomenon at frequencies larger than this critical frequency could contribute to the task of maintaining equilibrium. A new statistical method is introduced based onto the recent progress in signal processing : the wavelets analysis. The algorithm is entirely automatic. Seventeen healthy young subjects were studied under quiet-standing conditions, the mean value of critical frequency is 1.8 Hz corresponding to a mean critical time scale 0.68 s. The algorithm is entirely automatic. 2025-03-28T13:57:54Z 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Oct 2001, Istanbul, Turkey. pp.1163-1166 Pierre R. Bertrand LAPSCO Jean-Marc Bardet LSP Michel Dabonneville LIMOS A. Mouzat LAPSCO Philippe Vaslin LIMOS