https://arxiv.org/api/0YjiuWmPO9iemJqpcY9E3hZKsBw2026-06-27T13:03:16Z9008144015http://arxiv.org/abs/2504.06520v2Multi-Frequency Reverberant Shear Waves for Assessing Tissue Dispersion in Optical Coherence Elastography2025-04-10T21:24:10ZOptical coherence elastography (OCE) is a powerful non-invasive imaging technique for high-resolution assessment of tissue elasticity and viscoelasticity. Accurate characterization of viscoelastic properties requires estimating shear wave speed (SWS) across multiple frequencies, as dispersion induces frequency-dependent variations in wave speed. This study introduces a novel multi-frequency reverberant OCE (MFR-OCE) approach to enhance viscoelastic tissue characterization by simultaneously capturing shear wave dynamics over multiple frequencies. We present the theoretical framework, experimental setup, and validation of MFR-OCE through simulations and experiments on gelatin phantoms, ex vivo porcine cornea, and ex vivo bovine liver. Simulation results demonstrate that MFR-OCE estimates SWS with errors below 4% relative to ground truth, and phantom experimental results show that MFR-OCE and single-frequency OCE also yield closely matching SWS estimates, with differences below 3%. Furthermore, the frequency-dependent dispersion coefficients extracted from biological tissues and phantoms align with the theoretical viscoelastic power law model. The gelatin phantoms exhibit a low viscoelastic behavior with an exponent of 0.13 for the power law fit of SWS, while the ex vivo porcine cornea demonstrates intermediate viscoelastic behavior, with a power law exponent of 0.33. The liver tissue shows significant frequency dependence, with a power law exponent of 0.51. These findings demonstrate that MFR-OCE enables a more comprehensive understanding of tissue mechanics and holds the potential for improving diagnostic accuracy in clinical applications.2025-04-09T01:40:05ZHamidreza AsemaniPanomsak MeemonGilmer Flores BarreraJannick P. RollandKevin J. Parkerhttp://arxiv.org/abs/2504.07933v1Geometric and Dosimetric Validation of Deformable Image Registration for Prostate MR-guided Adaptive Radiotherapy2025-04-10T17:47:47ZObjective: Quantify geometric and dosimetric accuracy of a novel prostate MR-to-MR deformable image registration (DIR) approach to support MR-guided adaptive radiation therapy dose accumulation.
Approach: We evaluated DIR accuracy in 25 patients treated with 30 Gy in 5 fractions on a 1.5 T MR-linac using an adaptive workflow. A reference MR was used for planning, with three images collected at each fraction: adapt MR for adaptive planning, verify MR for pretreatment position verification and beam-on for capturing anatomy during radiation delivery. We assessed three DIR approaches: intensity-based, intensity-based with controlling structures (CS) and novel intensity based with controlling structures and points of interest (CS+P). DIRs were performed between the reference and fraction images and within fractions. We propagated CTV, bladder, and rectum contours using the DIRs and compared to manual contours using Dice similarity coefficient, mean distance to agreement (DTAmean), and dose-volume metrics.
Results: CS and CS+P improved geometric agreement between contours over intensity-only DIR. DTAmean for reference-to-beam-on intensity-only DIR was 0.131+/-0.009cm (CTV), 0.46+/-0.08cm (bladder), and 0.154+/-0.013cm (rectum). For the CS, the values were 0.018+/-0.002cm, 0.388+/-0.14cm, and 0.036+/-0.013cm. For CS+P these values were 0.015+/-0.001cm, 0.025+/-0.004cm, and 0.021+/-0.002cm. Dosimetrically, comparing CS and CS+P for reference to beam-on DIRs resulted in a change of CTV D98% from [-29cGy, 19cGy] to [-18cGy, 26cGy], rectum D1cc from [-106cGy, 72cGy] to [-52cGy, 74cGy], and bladder D5cc from [-51cGy, 544cGy] to [-79cGy, 36cGy].
Significance: CS improved geometric and dosimetric accuracy over intensity-only DIR, with CS+P providing the most consistent performance. However, session image segmentation remains a challenge, which may be addressed with automated contouring.2025-04-10T17:47:47ZVictor N. MalkovMayo Clinic, Department of Radiation Oncology, Rochester, MN, USARadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaIymad R. MansourRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaVickie KongRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaWinnie LiRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaJennifer DangRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaParisa SadeghiRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaInmaculada NavarroRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaJerusha PadayacheeRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaPeter ChungRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaJeff D. WinterRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, CanadaTony TadicRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Ontario, Canadahttp://arxiv.org/abs/2502.19376v2Neutron Beam Shaping by Ghost Projection2025-04-10T17:41:33ZWe present a method to shape a neutron beam and project any specified target image using a single universal patterned mask that is transversely displaced. The method relies on ``ghost projection'', which is a reversed form of classical ghost imaging. A set of sub-mask regions that combine to construct the required beam shape is computed; illumination of each region with the determined exposure time projects the shaped beam. We demonstrate this method experimentally, using the Dingo neutron imaging beamline at the OPAL nuclear research reactor (Australia). The ability to shape a neutron beam ``on demand'' allows selective dose delivery away from sensitive areas of samples, such as in cultural heritage artifacts. It also benefits irradiation techniques, e.g., in testing resilience of electronic components for space and defense technologies or neutron therapies.2025-02-26T18:21:26ZAndrew M. KingstonAlaleh AminzadehLindon RobertsJeremy M. C. BrownFilomena SalveminiJoseph J. BevittUlf GarbeDavid M. Paganinhttp://arxiv.org/abs/2504.07775v1Focal Cortical Dysplasia Type II Detection Using Cross Modality Transfer Learning and Grad-CAM in 3D-CNNs for MRI Analysis2025-04-10T14:15:16ZFocal cortical dysplasia (FCD) type II is a major cause of drug-resistant epilepsy, often curable only by surgery. Despite its clinical importance, the diagnosis of FCD is very difficult in MRI because of subtle abnormalities, leading to misdiagnosis. This study investigates the use of 3D convolutional neural networks (3D-CNNs) for FCD detection, using a dataset of 170 subjects (85 FCD patients and 85 controls) composed of T1-weighted and FLAIR MRI scans. In particular, it investigates the benefits obtained from cross-modality transfer learning and explainable artificial intelligence (XAI) techniques, in particular Gradient-weighted Class Activation Mapping (Grad-CAM). ResNet architectures (ResNet-18, -34, and -50) were implemented, employing transfer learning strategies that used pre-trained weights from segmentation tasks. Results indicate that transfer learning significantly enhances classification accuracy (up to 80.3%) and interpretability, as measured by a novel Heat-Score metric, which evaluates the model's focus on clinically relevant regions. Improvements in the Heat-Score metric underscore the model's seizure zone localization capabilities, bringing AI predictions and clinical insights closer together. These results highlight the importance of transfer learning, including cross-modality, and XAI in advancing AI-based medical diagnostics, especially for difficult-to-diagnose pathologies such as FCD.2025-04-10T14:15:16ZLorenzo LasagniAntonio CiccaroneRenzo GuerriniMatteo LengeLudovico D'incertihttp://arxiv.org/abs/2407.08574v3Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner2025-04-08T16:49:02ZIn state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum-entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and para-positronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening new avenues for exploring polarization correlations in PET as a diagnostic indicator.2024-07-11T15:01:31ZP. MoskalD. KumarS. SharmaE. Y. BeyeneN. ChugA. CoussatC. CurceanuE. CzerwinskiM. DasK. DulskiM. GorgolB. JasinskaK. KacprzakT. KaplanogluL. KaplonT. KozikE. LisowskiF. LisowskiW. MrykaS. NiedzwieckiS. ParzychE. P. del RioM. RadlerM. SkurzokE. L. StepienP. TantyK. Tayefi ArdebiliK. Valsan Eliyanhttp://arxiv.org/abs/2504.06195v1Accuracy Enhancement in Refractive Index Sensing via Full-Spectrum Machine Learning Modeling2025-04-08T16:37:53ZWe present a full-spectrum machine learning framework for refractive index sensing using simulated absorption spectra from meta-grating structures composed of titanium or silicon nanorods under TE and TM polarizations. Linear regression was applied to 80 principal components extracted from each spectrum, and model performance was assessed using five-fold cross-validation, simulating real-world biosensing scenarios where unknown patient samples are predicted based on standard calibration data. Titanium-based structures, dominated by broadband intensity changes, yielded the lowest mean squared errors and the highest accuracy improvements: up to a 6065-fold reduction compared to the best single-feature model. In contrast, silicon-based structures, governed by narrow resonances, showed more modest gains due to spectral nonlinearity that limits the effectiveness of global linear models. We also show that even the best single-wavelength predictor is identified through data-driven analysis, not visual selection, highlighting the value of automated feature preselection. These findings demonstrate that spectral shape plays a key role in modeling performance and that full-spectrum linear approaches are especially effective for intensity-modulated index sensors.2025-04-08T16:37:53Z21 pages, 8 figures, 1 tableMajid AalizadehChinmay RautMorteza Azmoudeh AfsharAli TabartehfarahaniXudong Fanhttp://arxiv.org/abs/2504.05990v1AI analysis of medical images at scale as a health disparities probe: a feasibility demonstration using chest radiographs2025-04-08T12:53:14ZHealth disparities (differences in non-genetic conditions that influence health) can be associated with differences in burden of disease by groups within a population. Social determinants of health (SDOH) are domains such as health care access, dietary access, and economics frequently studied for potential association with health disparities. Evaluating SDOH-related phenotypes using routine medical images as data sources may enhance health disparities research. We developed a pipeline for using quantitative measures automatically extracted from medical images as inputs into health disparities index calculations. Our study focused on the use case of two SDOH demographic correlates (sex and race) and data extracted from chest radiographs of 1,571 unique patients. The likelihood of severe disease within the lung parenchyma from each image type, measured using an established deep learning model, was merged into a single numerical image-based phenotype for each patient. Patients were then separated into phenogroups by unsupervised clustering of the image-based phenotypes. The health rate for each phenogroup was defined as the median image-based phenotype for each SDOH used as inputs to four imaging-derived health disparities indices (iHDIs): one absolute measure (between-group variance) and three relative measures (index of disparity, Theil index, and mean log deviation). The iHDI measures demonstrated feasible values for each SDOH demographic correlate, showing potential for medical images to serve as a novel probe for health disparities. Large-scale AI analysis of medical images can serve as a probe for a novel data source for health disparities research.2025-04-08T12:53:14Z21 pages, 4 figuresHeather M. WhitneyHui LiKaren DrukkerElbert HuangMaryellen L. Gigerhttp://arxiv.org/abs/2504.05884v1Endoscopic fiber-coupled diamond magnetometer for cancer surgery2025-04-08T10:17:43ZInteroperative measurements using magnetic sensors is a valuable technique in cancer surgery for finding magnetic tracers. Here we present a fiber-coupled nitrogen-vacancy (N-V) center magnetometer capable of detecting iron oxide suspension (MagTrace from Endomagnetics Ltd.) used in breast cancer surgeries. Detection of an iron mass as low as 0.56~mg has been demonstrated, 100 times less than that of a recommended dose at a maximum distance of 5.8~mm. Detection of an iron concentration as low as 2.8 mg/ml has also been demonstrated, 20 times less than a recommended dose. The maximum working distance from the sensor can be as large as 14.6~mm for higher concentrations. The sensor head has a maximum diameter of 10~mm which would allow it to be used for endoscopy, laparoscopy and interoperative surgery.2025-04-08T10:17:43Z9 pages, 15 figuresPhysical Review Applied 24, 024029 (2025)A. J. NewmanS. M. GrahamC. J. StephenA. M. EdmondsM. L. MarkhamG. W. Morley10.1103/znt3-988whttp://arxiv.org/abs/2504.06315v1Eye2Heart : a validated lumped-parameter model bridging cardiovascular and ocular dynamics2025-04-08T08:01:07ZThe cardiovascular and ocular systems are intricately connected, with hemodynamic interactions playing a crucial role in both physiological regulation and pathological conditions. However, existing models often treat these systems separately, limiting the understanding of their interdependence. In this study, we present the Eye2Heart model, a novel closed-loop mathematical framework that integrates cardiovascular and ocular dynamics. Using an electricalhydraulic analogy, the model describes the interactions between the heart and retinal circulation through a system of ordinary differential equations. The model is validated against clinical and experimental data, demonstrating its ability to reproduce key cardiovascular parameters (e.g., stroke volume, cardiac output) and ocular hemodynamics (e.g., retinal blood flow). Additionally, we explore in silico the effects of intraocular pressure (IOP) and left ventricular compliance on both local ocular and global systemic circulation, revealing critical dependencies between cardiovascular and ocular health. The results highlight the model's potential for studying cardiovascular diseases with ocular manifestations, paving the way for patient-specific data integration and expanding applications in personalized medicine.2025-04-08T08:01:07ZLorenzo SalaMaIAGE, MUSCAMohamed ZaidMAP5 - UMR 8145Faith HughesMAP5 - UMR 8145Marcela SzoposMAP5 - UMR 8145Virginia H. HuxleyMizzouAlon HarrisMSSMGiovanna GuidoboniSergey Lapinhttp://arxiv.org/abs/2406.15609v3Automated radiotherapy treatment planning guided by GPT-4Vision2025-04-08T00:19:04ZObjective: Radiotherapy treatment planning is a time-consuming and potentially subjective process that requires the iterative adjustment of model parameters to balance multiple conflicting objectives. Recent advancements in frontier Artificial Intelligence (AI) models offer promising avenues for addressing the challenges in planning and clinical decision-making. This study introduces GPT-RadPlan, an automated treatment planning framework that integrates radiation oncology knowledge with the reasoning capabilities of large multi-modal models, such as GPT-4Vision (GPT-4V) from OpenAI.
Approach: Via in-context learning, we incorporate clinical requirements and a few (3 in our experiments) approved clinical plans with their optimization settings, enabling GPT-4V to acquire treatment planning domain knowledge. The resulting GPT-RadPlan system is integrated into our in-house inverse treatment planning system through an application programming interface (API). For a given patient, GPT-RadPlan acts as both plan evaluator and planner, first assessing dose distributions and dose-volume histograms (DVHs), and then providing textual feedback on how to improve the plan to match the physician's requirements. In this manner, GPT-RadPlan iteratively refines the plan by adjusting planning parameters, such as weights and dose objectives, based on its suggestions.
Main results: The efficacy of the automated planning system is showcased across 17 prostate cancer and 13 head and neck cancer VMAT plans with prescribed doses of 70.2 Gy and 72 Gy, respectively, where we compared GPT-RadPlan results to clinical plans produced by human experts. In all cases, GPT-RadPlan either outperformed or matched the clinical plans, demonstrating superior target coverage and reducing organ-at-risk doses by 5 Gy on average (15 percent for prostate and 10-15 percent for head and neck).2024-06-21T19:23:03Z12 pages, 4 figuresSheng LiuOscar Pastor-SerranoYizheng ChenMatthew GopaulchanWeixing LiangMark BuyyounouskiErqi PollomQuynh-Thu LeMichael GensheimerPeng DongYong YangJames ZouLei Xinghttp://arxiv.org/abs/2504.05302v1Ionomeric extracellular matrices for dynamic soft robotic tissue engineering devices through protein sulfonation2025-04-07T17:59:11ZConventional tissue engineering methodologies frequently depend on pharmacological strategies to induce or expedite tissue repair. However, bioengineered strategies incorporating biophysical stimulation have emerged as promising alternatives. Electroactive materials facilitate the provision of controlled electrical, mechanical, and electromechanical stimuli, which support cell proliferation and tissue remodelling. Despite their ability to supply external electrical and mechanical stimuli to the tissue microenvironment, the electroactive polymers in use today often lack critical biochemical signals essential for native-like cell-cell and cell-scaffold interactions, thereby constraining their regenerative capabilities. To address the demand for biomimetic materials that possess enhanced capabilities in promoting cell and tissue stimulation, we present the development of a novel class of polymers called ionomeric extracellular matrices (iECMs). By utilising the linker-mediated conjugation of sulfonic acid biomolecules (taurine) to the backbone of an extracellular matrix protein (collagen), we illustrate the potential of iECMs as the first electromechanical actuating material platform derived entirely from ECM materials, paving the way for dynamic and soft-robotic platforms for a wide range of tissue engineering applications.2025-04-07T17:59:11ZMatthew K BurgessRyan T MurrayVeronica M LucianZekun LiuRobin O ClevelandCallum J BeestonMalavika Nairhttp://arxiv.org/abs/2504.04871v1Characteristics of Ge-doped Multi-Mode Fibers in Total Ionizing Dose2025-04-07T09:26:05ZPurpose: The fiber optical links in 850 nm band with Ge-doped multi-mode (MM) fibers are well developed for data transmission at 10 Gbps and higher. The applications in nuclear environments require radiation resistance. The characteristics of Ge-doped MM fibers are investigated for Radiation Induced Attenuation (RIA) in Total Ionizing Dose (TID).
Methods: Commercial samples of Ge-doped MM fibers were irradiated in Go-60 gamma rays at dose rates of 5 to 1.4k Gy(SiO2)/hr. The fiber samples were packaged in water tanks maintained at constant temperatures in the range of -15 to 45 degC. The optical power transmitted through the fibers were recorded in irradiation, and in annealing when the source was shielded. The measurements of RIA in time are analyzed for dose rate and temperature dependences.
Results: Ge-doped fiber samples of OM2 to OM4 grades were investigated for attenuation of optical power in radiation ionizing dose. Depending on the fabrication technology, two of the fiber types show radiation resistance with the RIAs of 0.2 dB/m and 0.05 dB/m, respectively, for the TID of 300 kGy(SiO2). At low dose rate of 5 Gy/hr, the RIA increases steadily and the annealing of low density ionizing defects does not cause notable deviation. At 1.4 kGy/hr the accumulated defects result to twice higher RIA during irradiation, and is worsen to a factor three in cold temperature. However, once the source is shielded the recovery is effective in a few hours.
Conclusion: The telecom products of 850 nm Ge-doped MM fibers provide high speed communication in distances of a few hundred meters. The industrial fabrication methods provide fibers that can endure radiation ionizing dose for applications in nuclear instrumentation.2025-04-07T09:26:05Z9 pages, 13 figuresDatao GongSuen HouBo-Jing JuangBin LinChonghan LiuTiankuan LiuMing QiYi YangJingbo YeLei ZhangLi ZhangHuiPing Zhuhttp://arxiv.org/abs/2504.03899v1A novel methodology to estimate pileup effects and induced error in microdosimetric spectra2025-04-04T19:41:17ZMicrodosimetry provides a superior characterization of the radiation field compared to conventional LET-based methodology, and for this reason it has become increasingly attractive for quality assurance in particle therapy. However, the typical particle rates used in the treatments lead to pileup, which distorts the experimental spectra, and thus compromises the accuracy of microdosimetric measurements, limiting their use in clinical settings. In this work, we investigated the pileup in a spherical Tissue Equivalent Proportional Counter (TEPC), and developed an algorithm to evaluate the contribution of this effect to the measured spectra. We exposed the TEPC to 11 and 70 MeV proton beams, and collected the microdosimetric spectra at rates in the $10^3$-$10^6$ pps range. Using a combination of GEANT4 Monte Carlo simulations and experimental data, we develop an algorithm capable of estimating the pileup probability affecting experimental measurements. The data suggest that the pileup probability has a linear increase with rate until it reaches a value of $15 \pm 3 \, \%$ at $28.2 \times 10^3$ pps, at which point it begins to saturate. Additionally, the outcomes from the comparison of the two proton energies suggest that the methodology used to estimate pileup can be used to predict the effects in clinical proton beams with similar energies. This same methodology can be applied to any type of microdosimetric measurement making it a reliable tool for addressing pileup issues and facilitating the application of microdosimetry in clinical settings.2025-04-04T19:41:17ZE. PierobonM. MissiaggiaF. G. CordoniC. La Tessahttp://arxiv.org/abs/2504.15287v1Continuum Damage Modeling of Biaxial Fatigue Failure in Whole Bone: A Hybrid Approach with Machine Learning Integration2025-04-04T17:41:44ZRepetitive loading of bone is associated with microdamage accumulation and material property degradation that may ultimately result in fatigue fracture. Our previous work used continuum damage mechanics (CDM)-based finite element (FE) modeling to predict stiffness loss and fatigue failure in whole bone; however, this model did not account for inter-specimen variability in fatigue behaviour and multiaxial loading effects, which limited its applied efficacy. In this study, we refined the CDM-based FE model to predict experimental fatigue-life measurements from 21 whole rabbit tibiae subjected to cyclic axial compression with different magnitudes of superposed torsion. Machine learning (ML) methods were used to predict damage parameters from initial, undamaged, conditions, which were then used to predicted stiffness degradation and fatigue failure with the CDM-based FE modeling pipeline. Regression analysis was used to compare CDM-based FE fatigue-life predictions with experimental measurements. A random forest ML model predicted specimen-specific damage parameters with high accuracy (R2 = 0.85) and the CDM-based FE models demonstrated remarkable predictive capability, explaining up to 91% of the variance in fatigue-life measurements. Stiffness degradation profiles also followed a similar trend to experimental measurements; however, this agreement worsened with the level of superposed torsion suggesting additional refinements to the model may be necessary. These findings demonstrate the efficacy of integrating ML with CDM-based FE modeling to predict fatigue life and stiffness degradation. The observed agreement with experimental measurements suggests the modeling framework may provide valuable information regarding the mechanisms of fatigue fracture in whole bone2025-04-04T17:41:44ZReza KakavandJonah M. DimnikIfaz T. HaiderW. Brent Edwardshttp://arxiv.org/abs/2504.03298v1Optimization of pulsed saturation transfer MR fingerprinting (ST MRF) acquisition using the Cramér-Rao bound and sequential quadratic programming2025-04-04T09:24:05ZPurpose: To develop a method for optimizing pulsed saturation transfer MR fingerprinting (ST MRF) acquisition. Methods: The Cramér-Rao bound (CRB) for variance assessment was employed on Bloch-McConnell-based simulated signals, followed by a numerical sequential quadratic programming optimization and basin-hopping avoidance of local minima. Validation was performed using L-arginine phantoms and healthy human volunteers (n=4) at 3T while restricting the scan time to be less than 40 s. Results: The proposed optimization approach resulted in a significantly improved agreement with reference gold standard values in vivo, compared to baseline non-optimized protocols (8$\%$ lower NRMSE, 7$\%$ higher SSIM, and 15$\%$ higher Pearson's r value, p<0.001). Conclusion: The combination of the CRB with sequential quadratic programming and a rapid Bloch-McConnell simulator offers a means for optimizing and accelerating pulsed CEST and semisolid magnetization transfer (MT) MRF acquisition.2025-04-04T09:24:05ZSubmitted to Magnetic Resonance in Medicine. This project was funded by the European Union (ERC, BabyMagnet, project no. 101115639). Views and opinions expressed are, however, those of the authors only and do not necessarily reflect those of the European Union or the European Research Council. Neither the European Union nor the granting authority can be held responsible for themMagnetic Resonance in Medicine, 1-13 (2025)Nikita VladimirovMoritz ZaissOr Perlman10.1002/mrm.70141