https://arxiv.org/api/rip69xNzgpFKaL030diO7Z8dt5U 2026-06-27T12:03:13Z 9008 1425 15 http://arxiv.org/abs/2504.10953v1 Intraoperative perfusion assessment by continuous, low-latency hyperspectral light-field imaging: development, methodology, and clinical application 2025-04-15T07:59:04Z Accurate assessment of tissue perfusion is crucial in visceral surgery, especially during anastomosis. Currently, subjective visual judgment is commonly employed in clinical settings. Hyperspectral imaging (HSI) offers a non-invasive, quantitative alternative. However, HSI imaging lacks continuous integration into the clinical workflow. This study presents a hyperspectral light field system for intraoperative tissue oxygen saturation (SO2) analysis and visualization. We present a correlation method for determining SO2 saturation with low computational demands. We demonstrate clinical application, with our results aligning with the perfusion boundaries determined by the surgeon. We perform and compare continuous perfusion analysis using two hyperspectral cameras (Cubert S5, Cubert X20), achieving processing times of < 170 ms and < 400 ms, respectively. We discuss camera characteristics, system parameters, and the suitability for clinical use and real-time applications. 2025-04-15T07:59:04Z 6 pages, 4 figures Proc. SPIE 13306, Advanced Biomedical and Clinical Diagnostic and Surgical Guidance Systems XXIII, 1330606 (20 March 2025) Stefan Kray Institute of Smart Systems and Services, Pforzheim University Andreas Schmid Institute of Smart Systems and Services, Pforzheim University Eric L. Wisotzky Computer Vision & Graphics, Vision & Imaging Technologies, Fraunhofer Heinrich-Hertz-Institute HHI, Berlin Visual Computing, Humboldt-University, Berlin Moritz Gerlich Institute of Smart Systems and Services, Pforzheim University Sebastian Apweiler Department of General-, Visceral- and Thoracic Surgery, Klinikum Darmstadt Anna Hilsmann Computer Vision & Graphics, Vision & Imaging Technologies, Fraunhofer Heinrich-Hertz-Institute HHI, Berlin Thomas Greiner Institute of Smart Systems and Services, Pforzheim University Peter Eisert Computer Vision & Graphics, Vision & Imaging Technologies, Fraunhofer Heinrich-Hertz-Institute HHI, Berlin Visual Computing, Humboldt-University, Berlin Werner Kneist Department of General-, Visceral- and Thoracic Surgery, Klinikum Darmstadt 10.1117/12.3042238 http://arxiv.org/abs/2504.10665v1 On the optimisation of the geometric pattern for structured illumination based X-ray phase contrast and dark field imaging: A simulation study and its experimental validation 2025-04-14T19:39:45Z Phase-contrast and dark-field imaging are relatively new X-ray imaging modalities that provide additional information to conventional attenuation-based imaging. However, this new information comes at the price of a more complex acquisition scheme and optical components. Among the different techniques available, such as Grating Interferometry or Edge Illumination, modulation-based and more generally single-mask/grid imaging techniques simplify these new procedures to obtain phase and dark-field images by shifting the experimental complexity to the numerical post-processing side. This family of techniques involves inserting a membrane into the X-ray beam that locally modulating the intensity to create a pattern on the detector which serves as a reference. However, the topological nature of the mask used seems to determine the quality of the reconstructed phase and dark-field images. We present in this article an in-depth study of the impact of the membrane parameters used in a single mask imaging approach. A spiral topology seems to be an optimum both in terms of resolution and contrast-to-noise ratio compared to random and regular patterns. 2025-04-14T19:39:45Z 19 pages, 5 figures Clara Magnin Laurene Quenot Dan Mihai Cenda Blandine Lantz Bertrand Faure Emmanuel Brun http://arxiv.org/abs/2504.10315v1 An energy optimization method based on mixed-integer model and variational quantum computing algorithm for faster IMPT 2025-04-14T15:24:23Z Intensity-modulated proton therapy (IMPT) offers superior dose conformity with reduced exposure to surrounding healthy tissues compared to conventional photon therapy. Improving IMPT delivery efficiency reduces motion-related uncertainties, enhances plan robustness, and benefits breath-hold techniques by shortening treatment time. Among various factors, energy switching time plays a critical role, making energy layer optimization (ELO) essential. This work develops an energy layer optimization method based on mixed integer model and variational quantum computing algorithm to enhance the efficiency of IMPT. The energy layer optimization problem is modeled as a mixed-integer program, where continuous variables optimize the dose distribution and binary variables indicate energy layer selection. To solve it, iterative convex relaxation decouples the dose-volume constraints, followed by the alternating direction method of multipliers (ADMM) to separate mixed-variable optimization and the minimum monitor unit (MMU) constraint. The resulting beam intensity subproblem, subject to MMU, either admits a closed-form solution or is efficiently solvable via conjugate gradient. The binary subproblem is cast as a quadratic unconstrained binary optimization (QUBO) problem, solvable using variational quantum computing algorithms. With nearly the same plan quality, the proposed method noticeable reduces the number of the used energies. For example, compared to conventional IMPT, QC can reduce the number of energy layers from 61 to 35 in HN case, from 56 to 35 in lung case, and from 59 to 32 to abdomen case. The reduced number of energies also results in fewer delivery time, e.g., the delivery time is reduced from 100.6, 232.0, 185.3 seconds to 90.7, 215.4, 154.0 seconds, respectively. 2025-04-14T15:24:23Z Ya-Nan Zhu Nimita Shinde Bowen Lin Hao Gao http://arxiv.org/abs/2410.02696v2 Evaluation of the two-voltage method for parallel-plate ionization chambers irradiated with pulsed beams 2025-04-14T14:21:44Z Air-vented ionization chambers exposed to clinical radiation beams may suffer from recombination during the drift of the charge carriers towards the electrodes. Thus, dosimetry protocols recommend the use of a correction factor, usually denominated saturation factor ($k_{\rm sat}$), to correct the ionization chamber readout for the incomplete collection of charge. The two-voltage method is the recommended methodology for the calculation of the saturation factor, however, it is based on the early Boag model, which only takes into account the presence of positive and negative ions in the ionization chamber and does not account for the electric field screening or the free electron contribution to the signal. The numerical simulation shows a better agreement with the experimental data than the current analytical theories in terms of charge collection efficiency. The classical two-voltage method, systematically overestimates the saturation factor, with differences increasing with dose per pulse also present at low dose per pulse. These results may have implications for the dosimetry with ionization chambers in therapy modalities that use a dose per pulse higher than conventional radiotherapy such as intraoperative radiotherapy but also in conventional dose per pulse for ionization chambers that suffer from significant charge recombination. 2024-10-03T17:20:38Z José Paz-Martín Andreas Schüller Alexandra Bourgouin Araceli Gago-Arias Diego M. Gonzalez-Castaño Nicolás Gómez-Fernández Juan Pardo-Montero Faustino Gómez 10.1002/mp.17814 http://arxiv.org/abs/2407.06165v2 Tumor likelihood estimation on MRI prostate data by utilizing k-Space information 2025-04-14T10:28:26Z We present a novel preprocessing and prediction pipeline for the classification of magnetic resonance imaging (MRI) that takes advantage of the information rich complex valued k-Space. Using a publicly available MRI raw dataset with 312 subject and a total of 9508 slices, we show the advantage of utilizing the k-Space for better prostate cancer likelihood estimation in comparison to just using the magnitudinal information in the image domain, with an AUROC of $86.1\%\pm1.8\%$. Additionally, by using high undersampling rates and a simple principal component analysis (PCA) for coil compression, we reduce the time needed for reconstruction by avoiding the time intensive GRAPPA reconstruction algorithm. By using digital undersampling for our experiments, we show that scanning and reconstruction time could be reduced. Even with an undersampling factor of 16, our approach achieves meaningful results, with an AUROC of $71.4\%\pm2.9\%$, using the PCA coil combination and taking into account the k-Space information. With this study, we were able to show the feasibility of preserving phase and k-Space information, with consistent results. Besides preserving valuable information for further diagnostics, this approach can work without the time intensive ADC and reconstruction calculations, greatly reducing the post processing, as well as potential scanning time, increasing patient comfort and allowing a close to real-time prediction. 2024-06-04T12:05:20Z M. Rempe F. Hörst C. Seibold B. Hadaschik M. Schlimbach J. Egger K. Kröninger F. Breuer M. Blaimer J. Kleesiek http://arxiv.org/abs/2504.05005v2 Can audio recordings be used to detect leaks and coughs during mechanical insufflation exsufflation (MI-E) treatment? 2025-04-14T09:32:03Z This report relates to a study group hosted by the EPSRC funded network, Integrating data-driven BIOphysical models into REspiratory MEdicine (BIOREME), and supported by SofTMech and Innovate UK, Business Connect. The BIOREME network hosts events, including this study group, to bring together multi-disciplinary researchers, clinicians, companies and charities to catalyse research in the applications of mathematical modelling for respiratory medicine. The goal of this study group was to provide an interface between companies, clinicians, and mathematicians to develop mathematical tools to the problems presented. The study group was held at The University of Glasgow on the 17 - 21 June 2024 and was attended by 16 participants from 8 different institutions. Below details the technical report of one of the challenges and the methods developed by the team of researchers who worked on this challenge. 2025-04-07T12:32:01Z Jonathan Brady Vijay Chandiramani Michelle Chatwin Emmanuel Lwele Aminat Yetunde Saula Peter Stewart Toby Stokes http://arxiv.org/abs/2311.12958v3 A nonlocal equation describing tumor growth 2025-04-14T07:04:38Z Cancer is a very complex phenomenon that involves many different scales and situations. In this paper we consider a free boundary problem describing the evolution of a tumor colony and we derive a new asymptotic model for tumor growth. We focus on the case of a single phase tumor colony taking into account chemotactic effects in an early stage where there is no necrotic inner region. Thus, our model is valid for the case of multilayer avascular tumors with very little access to both nutrients and inhibitors or the case where the amount of nutrients and inhibitors is very similar to the amount consumed by the multilayer tumor cells. Our model takes the form of a single nonlocal and nonlinear partial differential equation. Besides deriving the model, we also prove a well-posedness result. 2023-11-21T19:53:33Z Improved introduction and updated references Rafael Granero-Belinchón Martina Magliocca http://arxiv.org/abs/2505.07823v1 Ultrahigh-speed digital holography for quantitative Doppler imaging of the human retina 2025-04-14T07:00:32Z High-speed digital holography reveals local blood flow contrasts in the eye fundus through deterministic signal analysis, leveraging a forward scattering model of dynamically diffused light. This approach enables the estimation of absolute blood flow in primary in-plane retinal arteries. 2025-04-14T07:00:32Z 3 pages, 2 figs Zacharie Auray Yann Fischer Olivier Martinache Michael Atlan http://arxiv.org/abs/2504.09601v1 Mixture-of-Shape-Experts (MoSE): End-to-End Shape Dictionary Framework to Prompt SAM for Generalizable Medical Segmentation 2025-04-13T14:34:52Z Single domain generalization (SDG) has recently attracted growing attention in medical image segmentation. One promising strategy for SDG is to leverage consistent semantic shape priors across different imaging protocols, scanner vendors, and clinical sites. However, existing dictionary learning methods that encode shape priors often suffer from limited representational power with a small set of offline computed shape elements, or overfitting when the dictionary size grows. Moreover, they are not readily compatible with large foundation models such as the Segment Anything Model (SAM). In this paper, we propose a novel Mixture-of-Shape-Experts (MoSE) framework that seamlessly integrates the idea of mixture-of-experts (MoE) training into dictionary learning to efficiently capture diverse and robust shape priors. Our method conceptualizes each dictionary atom as a shape expert, which specializes in encoding distinct semantic shape information. A gating network dynamically fuses these shape experts into a robust shape map, with sparse activation guided by SAM encoding to prevent overfitting. We further provide this shape map as a prompt to SAM, utilizing the powerful generalization capability of SAM through bidirectional integration. All modules, including the shape dictionary, are trained in an end-to-end manner. Extensive experiments on multiple public datasets demonstrate its effectiveness. 2025-04-13T14:34:52Z Accepted to CVPR 2025 workshop Jia Wei Xiaoqi Zhao Jonghye Woo Jinsong Ouyang Georges El Fakhri Qingyu Chen Xiaofeng Liu http://arxiv.org/abs/2504.10534v1 Imaging Transformer for MRI Denoising: a Scalable Model Architecture that enables SNR << 1 Imaging 2025-04-13T02:36:15Z Purpose: To propose a flexible and scalable imaging transformer (IT) architecture with three attention modules for multi-dimensional imaging data and apply it to MRI denoising with very low input SNR. Methods: Three independent attention modules were developed: spatial local, spatial global, and frame attentions. They capture long-range signal correlation and bring back the locality of information in images. An attention-cell-block design processes 5D tensors ([B, C, F, H, W]) for 2D, 2D+T, and 3D image data. A High Resolution (HRNet) backbone was built to hold IT blocks. Training dataset consists of 206,677 cine series and test datasets had 7,267 series. Ten input SNR levels from 0.05 to 8.0 were tested. IT models were compared to seven convolutional and transformer baselines. To test scalability, four IT models 27m to 218m parameters were trained. Two senior cardiologists reviewed IT model outputs from which the EF was measured and compared against the ground-truth. Results: IT models significantly outperformed other models over the tested SNR levels. The performance gap was most prominent at low SNR levels. The IT-218m model had the highest SSIM and PSNR, restoring good image quality and anatomical details even at SNR 0.2. Two experts agreed at this SNR or above, the IT model output gave the same clinical interpretation as the ground-truth. The model produced images that had accurate EF measurements compared to ground-truth values. Conclusions: Imaging transformer model offers strong performance, scalability, and versatility for MR denoising. It recovers image quality suitable for confident clinical reading and accurate EF measurement, even at very low input SNR of 0.2. 2025-04-13T02:36:15Z Hui Xue Sarah M. Hooper Rhodri H. Davies Thomas A. Treibel Iain Pierce John Stairs Joseph Naegele Charlotte Manisty James C. Moon Adrienne E. Campbell-Washburn Peter Kellman Michael S. Hansen http://arxiv.org/abs/2502.04493v2 LUND-PROBE -- LUND Prostate Radiotherapy Open Benchmarking and Evaluation dataset 2025-04-12T12:49:13Z Radiotherapy treatment for prostate cancer relies on computed tomography (CT) and/or magnetic resonance imaging (MRI) for segmentation of target volumes and organs at risk (OARs). Manual segmentation of these volumes is regarded as the gold standard for ground truth in machine learning applications but to acquire such data is tedious and time-consuming. A publicly available clinical dataset is presented, comprising MRI- and synthetic CT (sCT) images, target and OARs segmentations, and radiotherapy dose distributions for 432 prostate cancer patients treated with MRI-guided radiotherapy. An extended dataset with 35 patients is also included, with the addition of deep learning (DL)-generated segmentations, DL segmentation uncertainty maps, and DL segmentations manually adjusted by four radiation oncologists. The publication of these resources aims to aid research within the fields of automated radiotherapy treatment planning, segmentation, inter-observer analyses, and DL model uncertainty investigation. The dataset is hosted on the AIDA Data Hub and offers a free-to-use resource for the scientific community, valuable for the advancement of medical imaging and prostate cancer radiotherapy research. 2025-02-06T20:44:42Z 4 figures Viktor Rogowski Lars E Olsson Jonas Scherman Emilia Persson Mustafa Kadhim Sacha af Wetterstedt Adalsteinn Gunnlaugsson Martin P. Nilsson Nandor Vass Mathieu Moreau Maria Gebre Medhin Sven Bäck Per Munck af Rosenschöld Silke Engelholm Christian Jamtheim Gustafsson http://arxiv.org/abs/2504.09193v1 Dynamic laboratory X-ray phase-contrast microtomography with structure-based prior regularisation 2025-04-12T12:17:21Z X-ray microtomography is a versatile tool allowing the measurement of the 3D structure of optically thick samples. As a non-destructive technique, it is readily adapted to 4D imaging, where a sample can be monitored over time, and especially in conjunction with the application of external stimuli. To apply this technique with the limited X-ray flux available at a conventional laboratory source, we leverage the contrast enhancement of free-space propagation phase-contrast imaging, achieving an increase in contrast-to-noise ratio of 5.8x. Furthermore, we combine this with iterative reconstruction, using regularisation by a structure-based prior from a high-quality reference scan of the object. This combination of phase-contrast imaging and iterative reconstruction leads to a 29.2x improvement in contrast-to-noise ratio compared to the conventional reconstruction. This enables fully dynamic X-ray microtomography, with a temporal resolution of 9 s at a voxel size of 10.5 $μ$m. We use this to measure the movement of a waterfront in the fine vessels of a wooden skewer, as a representative example of dynamic system evolving on the scale of tens of seconds. 2025-04-12T12:17:21Z 13 pages, 7 figures Harry Allan Tom Partridge Joseph Jacob Marco Endrizzi 10.1088/1361-6501/ae01c8 http://arxiv.org/abs/2504.08969v1 An in silico approach to analyse the influence of carotid haemodynamics on cardiovascular events using 3D tomographic ultrasound and computational fluid dynamics 2025-04-11T20:48:32Z Analysing the haemodynamics of flow in carotid artery disease serves as a means to better understand the development and progression of associated complex diseases. Carotid artery disease can predispose people to major adverse cardiovascular events. Understanding the nature of carotid blood flow using in silico methods enables the extraction of relevant metrics that are not accessible in vivo. This study develops computationally efficient means of modelling patient-specific flow, utilising 3D tomographic ultrasound to generate anatomically faithful reconstructions including artherosclerotic plaque, and computational fluid dynamics to simulate flow in these arteries. A computationally efficient model has been proposed here, which has been used to conduct simulations for a large dataset, the results of which where stastitically analysed to test the association of relevant haemodynamic metrics with cardiovascular events. The incidence of major cardiovascular diseases in carotid artery disease patients has been shown to have an association with flow vorticity in the region of interest, and less so with the absolute magnitudes of wall shear stress. 2025-04-11T20:48:32Z 15 pages, 8 figures Author contribution: Methods:SS,ABH,AR,SKR Investigation:SS,ABH,AR,SKR Software:SS,JW Validation:SS,JW Formal analysis:SS,EM. Visualisation:SS Resources:SS,ABH,AR,SKR Data curation:SS,SKR Writing-draft:SS Writing-editing:SS, EM,ABH,AR,SKR Supervision:EM,ABH,AR,SKR Funding acquisiton:EM,ABH,AR,SKR Conceptualisation:ABH,AR, SKR Project admin:ABH, SKR Sampad Sengupta Department of Mechanical and Aerospace Engineering, School of Engineering, The University of Manchester, Manchester, UK Department of Chemical Engineering and Biotechnology, The University of Cambridge, Cambridge, UK Emily Manchester Department of Mechanical and Aerospace Engineering, School of Engineering, The University of Manchester, Manchester, UK Jie Wang Department of Mechanical and Aerospace Engineering, School of Engineering, The University of Manchester, Manchester, UK Ajay B. Harish Department of Mechanical and Aerospace Engineering, School of Engineering, The University of Manchester, Manchester, UK Alistair Revell Department of Mechanical and Aerospace Engineering, School of Engineering, The University of Manchester, Manchester, UK Steven K. Rogers Manchester Academic Vascular Research and Innovation Centre Division of Nursing, Midwifery and Social Work, School of Health Sciences, Faculty of Medicine, Biology and Health, University of Manchester, Manchester, UK http://arxiv.org/abs/2504.08351v1 Thoracic Fluid Measurements by Bioimpedance: A Comprehensive Survey 2025-04-11T08:39:02Z Bioimpedance is an extensively studied non-invasive technique with diverse applications in biomedicine. This comprehensive review delves into the foundational concepts, technical intricacies, and practical implementations of bioimpedance. It elucidates the underlying principles governing bioimpedance measurements, including the relevant physics equations employed for estimating body fluid levels. Moreover, a thorough examination of the prevalent single-chip analog front end (AFE) available in the market, such as AD5933, MAX30001, AD5940, and AFE4300, is conducted, shedding light on their specifications and functionalities. The review focuses on using bioimpedance to assess thoracic impedance for heart failure detection by utilizing the relation between lung water and heart failure. Traditional techniques are compared with bioimpedance-based methods, demonstrating the latter's efficacy as a non-invasive tool for cardiac evaluation. In addition, the review addresses the technical limitations and challenges associated with bioimpedance. Pertinent issues such as contact impedance, motion artifacts, calibration, and validation regarding their impact on measurement precision and dependability are thoroughly examined. The review also explores strategies and advancements in using artificial intelligence to mitigate these challenges. 2025-04-11T08:39:02Z 15 pages, 2 figures, 2 tables Manender Yadav Shreyansh Shukla Varsha Kiron U. Deva Priyakumar Maitreya Maity http://arxiv.org/abs/2503.15711v2 VPAL: A novel method to reduce reconstruction time for 5D free-running imaging 2025-04-11T03:11:12Z Purpose: Ferumoxytal-enhanced 5D free-running whole heart CMR provides image quality comparable to CTA, but requires hours-long reconstruction time, preventing clinical usage. This study developed a variable projection augmented Lagrangian (VPAL) method for 5D motion-resolved image reconstruction and compared it with alternating direction method of multipliers (ADMM) in five numerical simulations and 15 in-vivo pediatric data set. Approach: Relative error of the reconstructed images against the ground-truth images was assessed in numerical simulations. In-vivo analysis compared reconstruction time, mid-short axis (SA) blood-myocardium sharpness, left ventricular ejection fraction (LVEF), and a radiologist's image quality ratings between VPAL and ADMM. A paired t-test (p<0.05) was used to determine statistical significance, while linear regression and Bland-Altman analysis for agreement assessments. Results: VPAL and ADMM had similar relative errors compared to the ground truth, p = 0.07. In in-vivo datasets, VPAL reduced the reconstruction time from 16.3 +/- 3.6 hours (ADMM) to 4.7 +/- 1.1 hours (VPAL), p=1e-10. Blood-myocardium border sharpness in VPAL closely correlates to ADMM , R^2 = 0.97. The LVEFs values measured by VPAL and ADMM reconstructions are largely similar, 56 +/- 6 % in ADMM and 56 +/- 6 % in VPAL, p=0.55. Both VPAL and ADMM reconstructions have good to excellent diagnostic ratings (VPAL vs. ADMM: 3.9 +/- 0.3 vs. 3.8 +/- 0.4 in 2-chamber; 3.9 +/- 0.4 vs. 3.9 +/- in 4-chamber; 3.7 +/- 0.5 vs. 3.7 +/- 0.5 in mid-SA reformatted views. Conclusion: VPAL enables faster reconstruction than ADMM while maintaining equivalent image quality for functional assessments, supporting its potential for clinical use. 2025-03-19T21:44:45Z Yitong Yang Muhammad Naeem Marly Van Assen Jerome Yerly Davide Piccini Matthias Stuber John Oshinski Matthias Chung