https://arxiv.org/api/MU3fZNmSTsdkN2KKsnWnlFdGmvQ2026-06-27T10:03:24Z9008139515http://arxiv.org/abs/2504.14724v2Parametrization of microbial survival models under UVC exposure2025-04-24T22:35:13ZThis study aims to identify and parameterize the optimal survival curves for 33 fundamental microorganisms subject to UVC exposure through experimental measurements. We compile published data on UVC doses and corresponding survival fractions for these microorganisms to estimate parameters for four prominent survival models: Single-target (ST), Multi-target (MT), Linear Quadratic (LQ), and Two-Stage Decay (TSD). The best-fitting model for each microorganism is determined by selecting the one with the lowest mean squared error (MSE) compared to the experimental data. Our analysis indicates that the MT model is the most frequently appropriate, accurately fitting 21 of the 33 microorganisms. The TSD model is the best fit for only three, while the LQ model, though occasionally suitable at lower doses, is often excluded due to unreliable performance at higher doses. The assessed models, particularly the MT model, demonstrate strong predictive capabilities for UVC surface sterilization of microorganisms. However, caution is warranted with the LQ model at higher doses due to its potential limitations.2025-04-20T19:37:11ZAikaterini A. TsantariKonstantinos K. DelibasisHarilaos G. SandalidisNestor D. Chatzidiamantishttp://arxiv.org/abs/2410.17119v2Dynamic Glucose Enhanced Imaging using Direct Water Saturation2025-04-24T16:00:00ZPurpose: Dynamic glucose enhanced (DGE) MRI studies employ chemical exchange saturation transfer (CEST) or spin lock (CESL) to study glucose uptake. Currently, these methods are hampered by low effect size and sensitivity to motion. To overcome this, we propose to utilize exchange-based linewidth (LW) broadening of the direct water saturation (DS) curve of the water saturation spectrum (Z-spectrum) during and after glucose infusion (DS-DGE MRI). Methods: To estimate the glucose-infusion-induced LW changes ($Δ$LW), Bloch-McConnell simulations were performed for normoglycemia and hyperglycemia in blood, gray matter (GM), white matter (WM), CSF, and malignant tumor tissue. Whole-brain DS-DGE imaging was implemented at 3 tesla using dynamic Z-spectral acquisitions (1.2 s per offset frequency, 38 s per spectrum) and assessed on four brain tumor patients using infusion of 35 g of D-glucose. To assess $Δ$LW, a deep learning-based Lorentzian fitting approach was employed on voxel-based DS spectra acquired before, during, and post-infusion. Area-under-the-curve (AUC) images, obtained from the dynamic $Δ$LW time curves, were compared qualitatively to perfusion-weighted imaging (PWI). Results: In simulations, $Δ$LW was 1.3%, 0.30%, 0.29/0.34%, 7.5%, and 13% in arterial blood, venous blood, GM/WM, malignant tumor tissue, and CSF, respectively. In vivo, $Δ$LW was approximately 1% in GM/WM, 5-20% for different tumor types, and 40% in CSF. The resulting DS-DGE AUC maps clearly outlined lesion areas. Conclusions: DS-DGE MRI is highly promising for assessing D-glucose uptake. Initial results in brain tumor patients show high-quality AUC maps of glucose-induced line broadening and DGE-based lesion enhancement similar and/or complementary to PWI.2024-10-22T15:50:47ZPublished in Magn Reson Med. doi: 10.1002/mrm.30447Magn Reson Med. 2025 Mar 17Linda KnutssonNirbhay N. YadavSajad Mohammed AliDavid Olayinka KamsonEleni DemetriouAnina SeidemoLindsay BlairDoris D. LinJohn LaterraPeter C. M. van Zijl10.1002/mrm.30447.10.1002/mrm.30447http://arxiv.org/abs/2504.17251v1Ultrafast ultrasound coded vector Doppler imaging of blood flow velocity and resistivity2025-04-24T05:01:06ZDynamic and precise measurement of cerebral blood flow velocity is crucial in neuroscience and the diagnosis of cerebrovascular diseases. Traditional color Doppler ultrasound can only measure the velocity component along the ultrasound beam, which restricts its ability to accurately capture the complete blood flow vector in complex environments. To overcome these limitations, we propose an ultrafast pulse-coded vector Doppler (PC-UVD) imaging method, utilizing Hadamard matrix-based pulse encoding to improve velocity estimation accuracy under low signal-to-noise ratio (SNR) conditions. Our study encompasses spiral flow simulations and in vivo rat brain experiments, showing significantly enhanced measurement precision compared to conventional ultrafast vector Doppler (UVD). This innovative approach enables the measurement of dynamic cerebral blood flow velocity within a single cardiac cycle, offering insights into the characteristics of cerebrovascular resistivity. The proposed PC-UVD method employs Hadamard matrix encoding of plane waves, boosting SNR without compromising temporal or spatial resolution. Velocity vectors are subsequently estimated using a weighted least squares (WLS) approach, with iterative residual-based weight optimization improving robustness to noise and minimizing the impact of outliers. The effectiveness of this technique is confirmed through simulations with a spiral blood flow phantom, demonstrating a marked improvement in velocity estimation accuracy, particularly in deep imaging regions with significant signal attenuation. In vivo experiments on rat brains further confirm that the proposed method offers greater accuracy than existing UVD approaches, particularly for small vessels. Notably, our method can precisely differentiate arterial from venous flow by analyzing pulsatility and resistivity within the cerebral vascular network.2025-04-24T05:01:06ZS. Yan, Y. Ding, G. Ma, Y. Fu, K. Xu, and D. Ta, Ultrafast Ultrasound Coded Vector Doppler Imaging of Blood Flow Velocity and Resistivity, Acta Physica Sinica, vol. 74, no. 1, 2025Shaoyuan YanYiming DingGuoao MaYapeng FuKailiang XuDean Ta10.7498/aps.74.20241454http://arxiv.org/abs/2504.17183v1Effect of Electrode Array Position on Electric Field Intensity in Glioblastoma Patients Undergoing Electric Field Therapy2025-04-24T01:36:29ZBackground: The intensity of the electric field applied to a brain tumor by electric field therapy is influenced by the position of the electrode array, which should be optimized based on the patient's head shape and tumor characteristics. This study assessed the effects of varying electrode positions on electric field intensity in glioblastoma multiforme (GBM) patients.
Methods: This study enrolled 13 GBM patients. The center of the MR slice corresponding to the center of the tumor was set as the reference point for the electrodes, creating pairs of electrode arrays in the top-rear and left-right positions. Based on this reference plan, four additional treatment plans were generated by rotating three of the four electrode arrays, all except the top electrode array, by 15$^\circ$ and 30$^\circ$ from their reference positions, resulting in a total of five treatment plans per patient. Electric field frequency was set at 200 kHz, and current density at 31 mArms/cm$^2$. The minimum and mean electric field intensities, homogeneity index (HI), and coverage index (CovI) were calculated and compared.
Results: The optimal plans showed differences ranging from-0.39% to 24.20% for minimum intensity and -14.29% to 16.67% for mean intensity compared to reference plans. HI and CovI varied from 0.00% to 48.65% and 0.00% to 95.3%, respectively. The average improvements across all patients were 8.96% for minimum intensity, 5.11% for mean intensity, 15.65% for HI, and 17.84% for CovI.
Conclusions: Optimizing electrode angle improves electric field therapy outcomes in GBM patients by maximizing field intensity and coverage. Keywords: electric field therapy; glioblastoma multiforme (GBM); treatment planning system (TPS); electrode array position; tumor coverage2025-04-24T01:36:29Z10 pages, 4 figuresYousun KoSangcheol KimTae Hyun KimDongho ShinHaksoo KimSung Uk LeeJonghyun KimMyonggeun Yoonhttp://arxiv.org/abs/2504.17161v1Invasion depth estimation of gastric cancer in early stage using circularly polarized light scattering: Phantom studies2025-04-24T00:43:24ZDepolarization of circularly polarized light due to multiple scattering in turbid media provides size distributions of scatterer. Applied it to the biological tissues as turbid media, scatters correspond to cell nuclei, which is abnormally grown in cancerous tissues. Therefore, the invasion depth of early-staged cancer can be estimated by comparisons of circular polarization of scattered light. In this study, we fabricated the optical phantoms made of resin and polystyrene beads to verify this technique by systematic experiments. The single-layered phantoms containing only one size of beads exhibits uniform monodispersed scattering media. Polarization images taken by a circular polarization imaging camera show systematically changes to the numerical density of scatters. Healthy and cancerous tissue phantoms exhibiting the lengths of mean free paths close to actual biological tissues were stacked to be bi-layered phantoms which imitates early-staged cancers. The averaged circular polarization values obtained from the images captured with the polarization camera are indicative of obvious changes depending on the thickness of cancerous layer of phantoms.2025-04-24T00:43:24ZMike R. MaskeyMitsuo FukunoAkane SaitoAsato EsumiTakahiro KuchimaruNozomi Nishizawahttp://arxiv.org/abs/2504.17114v1Anatomy-constrained modelling of image-derived input functions in dynamic PET using multi-organ segmentation2025-04-23T21:47:05ZAccurate kinetic analysis of [$^{18}$F]FDG distribution in dynamic positron emission tomography (PET) requires anatomically constrained modelling of image-derived input functions (IDIFs). Traditionally, IDIFs are obtained from the aorta, neglecting anatomical variations and complex vascular contributions. This study proposes a multi-organ segmentation-based approach that integrates IDIFs from the aorta, portal vein, pulmonary artery, and ureters. Using high-resolution CT segmentations of the liver, lungs, kidneys, and bladder, we incorporate organ-specific blood supply sources to improve kinetic modelling. Our method was evaluated on dynamic [$^{18}$F]FDG PET data from nine patients, resulting in a mean squared error (MSE) reduction of $13.39\%$ for the liver and $10.42\%$ for the lungs. These initial results highlight the potential of multiple IDIFs in improving anatomical modelling and fully leveraging dynamic PET imaging. This approach could facilitate the integration of tracer kinetic modelling into clinical routine.2025-04-23T21:47:05ZThe code is available under https://github.com/tinolan/curve_fit_multi_idifValentin LangerKartikay TehlanThomas Wendlerhttp://arxiv.org/abs/2502.16746v2Resolving quantitative MRI model degeneracy in self-supervised machine learning2025-04-23T10:15:46ZQuantitative MRI (qMRI) estimates tissue properties of interest from measured MRI signals. This process is conventionally achieved by model fitting, whose computational expense limits qMRI's clinical use, motivating recent development of machine learning-based methods. Self-supervised approaches are particularly popular as they avoid the pitfall of distributional shift that affects supervised methods. However, it is unknown how such methods behave if similar signals can result from multiple tissue properties, a common challenge known as model degeneracy. Understanding this is crucial for ascertaining the scope within which self-supervised approaches may be applied. To this end, this work makes two contributions. First, we demonstrate that model degeneracy compromises self-supervised approaches, motivating the development of mitigation strategies. Second, we propose a mitigation strategy based on applying appropriate constraining transforms on the output of the bottleneck layer of the autoencoder network typically employed in self-supervised approaches. We illustrate both contributions using the estimation of proton density fat fraction and $R_2^*$ from chemical shift-encoded MRI, an ideal exemplar due to its exhibition of degeneracy across the full parameter space. The results from both simulation and $\textit{in vivo}$ experiments demonstrate that the proposed strategy helps resolve model degeneracy.2025-02-23T23:22:44ZAccepted at IPMI 2025Information Processing in Medical Imaging. IPMI 2025. Lecture Notes in Computer Science, vol 15830. Springer, ChamGiulio V. MinoreLouis Dwyer-HemmingsTimothy J. P. BrayHui Zhang10.1007/978-3-031-96625-5_13http://arxiv.org/abs/2504.16534v1Partitioning of multiple brain metastases improves dose gradients in single-isocenter radiosurgery2025-04-23T09:02:57ZBackground: A growing number of cancer patients with brain metastases can benefit from stereotactic radiosurgery (SRS) thanks to recent advances in systemic therapies. With an increasing patient load, single-isocenter treatments on widely available C-arm linear accelerators are an attractive option. However, the planning of such treatments is challenging for multi-target cases due to the island blocking problem, which occurs when the multi-leaf collimator cannot conform to all targets simultaneously.
Purpose: We propose a multi-target partitioning algorithm that mitigates excessive exposure of normal tissue caused by the island blocking problem.
Methods: The algorithm divides (partitions) the set of targets into subsets to treat with separate arc passes, optimizing both subsets and collimator angles to minimize island blocking. The algorithm was incorporated into a fully automated treatment planning script and evaluated on 20 simulated patient cases, each with 10 brain metastases and 21 Gy prescriptions. It was also retrospectively evaluated on six clinical cases.
Results: Partitioning significantly improved the gradient index, global efficiency index, and brain V12Gy compared to simultaneous treatment of all metastases. For example, the average gradient index improved from 5.9 to 3.3, global efficiency index from 0.32 to 0.46, and normal brain V12Gy from 49 cm3 to 26 cm3 between 3 and 9 arcs. The proposed algorithm outperformed baselines in utilizing a limited number of arcs. All target partitioning strategies increased the total number of monitor units (MUs).
Conclusions: The dose gradient in single-isocenter VMAT plans can be substantially improved by treating a smaller subset of metastases at a time. This requires more MUs and arcs, implying a trade-off between delivery time and plan quality which can be explored using the algorithm proposed in this paper.2025-04-23T09:02:57Z33 pages, 7 figuresMed Phys. 2025; 52:e18117Johan SundströmAnton FinnsonElin HynningGeert De KerfAlbin Fredriksson10.1002/mp.18117http://arxiv.org/abs/2502.03731v2A Physiological-Model-Based Neural Network Framework for Blood Pressure Estimation from Photoplethysmography Signals2025-04-23T08:59:48ZContinuous blood pressure (BP) estimation via photoplethysmography (PPG) remains a significant challenge, particularly in providing comprehensive cardiovascular insights for hypertensive complications. This study presents a novel physiological model-based neural network (PMB-NN) framework for BP estimation from PPG signals, incorporating the identification of total peripheral resistance (TPR) and arterial compliance (AC) to enhance physiological interpretability. Preliminary experimental results, obtained from a single healthy participant under varying activity intensities, demonstrated promising accuracy, with a median standard deviation of 6.88 mmHg for systolic BP and 3.72 mmHg for diastolic BP. The median error for TPR and AC was 0.048 mmHg*s/ml and -0.521 ml/mmHg, respectively. Consistent with expectations, both estimated TPR and AC exhibited a reduction as activity intensity increased.2025-02-06T02:46:51ZYaowen ZhangLibera FresielloPeter H. VeltinkDirk W. DonkerYing Wanghttp://arxiv.org/abs/2504.10916v2Embedding Radiomics into Vision Transformers for Multimodal Medical Image Classification2025-04-23T03:21:07ZBackground: Deep learning has significantly advanced medical image analysis, with Vision Transformers (ViTs) offering a powerful alternative to convolutional models by modeling long-range dependencies through self-attention. However, ViTs are inherently data-intensive and lack domain-specific inductive biases, limiting their applicability in medical imaging. In contrast, radiomics provides interpretable, handcrafted descriptors of tissue heterogeneity but suffers from limited scalability and integration into end-to-end learning frameworks. In this work, we propose the Radiomics-Embedded Vision Transformer (RE-ViT) that combines radiomic features with data-driven visual embeddings within a ViT backbone.
Purpose: To develop a hybrid RE-ViT framework that integrates radiomics and patch-wise ViT embeddings through early fusion, enhancing robustness and performance in medical image classification.
Methods: Following the standard ViT pipeline, images were divided into patches. For each patch, handcrafted radiomic features were extracted and fused with linearly projected pixel embeddings. The fused representations were normalized, positionally encoded, and passed to the ViT encoder. A learnable [CLS] token aggregated patch-level information for classification. We evaluated RE-ViT on three public datasets (including BUSI, ChestXray2017, and Retinal OCT) using accuracy, macro AUC, sensitivity, and specificity. RE-ViT was benchmarked against CNN-based (VGG-16, ResNet) and hybrid (TransMed) models.
Results: RE-ViT achieved state-of-the-art results: on BUSI, AUC=0.950+/-0.011; on ChestXray2017, AUC=0.989+/-0.004; on Retinal OCT, AUC=0.986+/-0.001, which outperforms other comparison models.
Conclusions: The RE-ViT framework effectively integrates radiomics with ViT architectures, demonstrating improved performance and generalizability across multimodal medical image classification tasks.2025-04-15T06:55:58Z27 pages, 3 figuresZhenyu YangHaiming ZhuRihui ZhangHaipeng ZhangJianliang WangChunhao WangMinbin ChenFang-Fang Yinhttp://arxiv.org/abs/2504.16036v1Rotational ultrasound and photoacoustic tomography of the human body2025-04-22T17:02:12ZImaging the human body's morphological and angiographic information is essential for diagnosing, monitoring, and treating medical conditions. Ultrasonography performs the morphological assessment of the soft tissue based on acoustic impedance variations, whereas photoacoustic tomography (PAT) can visualize blood vessels based on intrinsic hemoglobin absorption. Three-dimensional (3D) panoramic imaging of the vasculature is generally not practical in conventional ultrasonography with limited field-of-view (FOV) probes, and PAT does not provide sufficient scattering-based soft tissue morphological contrast. Complementing each other, fast panoramic rotational ultrasound tomography (RUST) and PAT are integrated for hybrid rotational ultrasound and photoacoustic tomography (RUS-PAT), which obtains 3D ultrasound structural and PAT angiographic images of the human body quasi-simultaneously. The RUST functionality is achieved in a cost-effective manner using a single-element ultrasonic transducer for ultrasound transmission and rotating arc-shaped arrays for 3D panoramic detection. RUST is superior to conventional ultrasonography, which either has a limited FOV with a linear array or is high-cost with a hemispherical array that requires both transmission and receiving. By switching the acoustic source to a light source, the system is conveniently converted to PAT mode to acquire angiographic images in the same region. Using RUS-PAT, we have successfully imaged the human head, breast, hand, and foot with a 10 cm diameter FOV, submillimeter isotropic resolution, and 10 s imaging time for each modality. The 3D RUS-PAT is a powerful tool for high-speed, 3D, dual-contrast imaging of the human body with potential for rapid clinical translation.2025-04-22T17:02:12ZYang ZhangShuai NaJonathan J. RussinKarteekeya SastryLi LinJunfu ZhengYilin LuoXin TongYujin AnPeng HuKonstantin MaslovTze-Woei TanCharles Y. LiuLihong V. Wanghttp://arxiv.org/abs/2504.15969v1Improved energy-based scatter estimation by incorporating local energy spectra and accelerating the parametric fitting2025-04-22T15:09:54ZPET requires accurate, precise, and efficient scatter correction techniques. Conventional scatter estimation typically relies on tail-fitted single-scatter simulation (SSS) strategy. However, the accuracy of tail-fitted SSS is limited, for example, by mismatches between the attenuation image and the PET emission data or by the presence of activity outside the FOV. These shortcomings can be addressed using energy-based scatter estimation (EBSE), as recently proposed by Efthimiou et al. and Hamill et al. The aim of this work is to 1. improve the accuracy of EBSE by accounting for the LOR dependence of the energy spectrum of unscattered photons, 2. improve the computational speed of EBSE through better initialization and a more efficient optimization algorithm. The proposed improved EBSE method models the energy probability density function (PDF) of both single and multiple scattered photons, and incorporates a position-dependent energy PDF for unscattered photons. These energy PDFs form the basis of two forward models used for scatter estimation based on 2D energy histograms. The performance of these models were evaluated using GATE Monte Carlo simulations and a NEMA phantom acquisition on a GE SIGNA PET/MR scanner. Furthermore, we assessed the stability of EBSE across the forward models by varying the number of counts in the 2D energy histograms via data mashing. EBSE outperformed tail-fitted SSS, particularly in regions near out-of-FOV activity. Our GATE simulations showed that incorporating a local energy for unscattered photons improves off-center regional quantification by approximately 2% points. Additionally, improved initialization combined with the NEGML optimizer enabling execution on a mashed TOF sinogram in 12 minutes on six-core CPU. The proposed method enhances both the accuracy and computational efficiency of EBSE, making it well-suited for clinical applications.2025-04-22T15:09:54ZSeyed Amir Zaman PourAhmadreza RezaeiFloris JansenKristof BaeteGeorg SchrammJohan Nuytshttp://arxiv.org/abs/2504.15824v1Characterization and ex vivo application of flexible 2D scintillating coatings in ultra-high dose rate electron beams for FLASH radiotherapy2025-04-22T12:11:50ZThe increasing interest in FLASH-RT has lead to the conversion of linear accelerators to enable ultra-high dose rate (UHDR) beams for preclinical research. Dosimetry hereof remains challenging with several crucial aspects missing. This work shows the challenges for real-time 2D UHDR dosimetry, and aims to present a solution in the context of preclinical irradiations in non-homogeneous UHDR electron beams. An experimental camera-scintillation sheet combination, was used to investigate the spatial dose distribution of a converted UHDR Varian Trilogy. The dosimetric system was characterized by variation of the number of pulses and source to surface distance (SSD) and its application was investigated by variation of bolus thickness and ambient light intensity. The challenges of prelcinical real time 2D dosimetry with scintillating coatings were assessed by ex vivo irradiations of a rat brain, mouse hindlimb and whole body mouse. Radiochromic EBT XD film was used as passive reference dosimeter. The coating showed a linear response with the number of pulses in the absence and presence of transparent bolus, up to 3 cm thick, and with the inverse squared SSD. The presence of ambient light reduces the signal-background ratio. The sheet showed to have sufficient flexibility to be molded on the subjects' surface, following its curvatures. Linearity with number of pulses was preserved in a preclinical setting. For small field sizes the light output became too low, resulting in noisy dose maps. The system showed robust within 5% for camera set up differences. Calibration of the system was complicated due to set up variations and the inhomogeneity of the beam. We showed the need for 2D real-time dosimetry to determine beam characteristics in non-homogeneous UHDR beams using a preclinical setting. We presented one solution to meet this need with scintillating based dosimetry.2025-04-22T12:11:50Z15 pagesVerdi VanreuselStephen BrownShujat AliThomas De KerfAnthony J. DoemerPaul LeblansBenjamin MovsasHumza NusratBehzad ShirmardKundan ThindSteve VanlanduitDirk VerellenAlessia GaspariniLuana de Freitas Nascimentohttp://arxiv.org/abs/2504.15496v1Fluorescence Reference Target Quantitative Analysis Library2025-04-22T00:03:55ZStandardized performance evaluation of fluorescence imaging systems remains a critical unmet need in the field of fluorescence-guided surgery (FGS). While the American Association of Physicists in Medicine (AAPM) TG311 report and recent FDA draft guidance provide recommended metrics for system characterization, practical tools for extracting these metrics remain limited, inconsistent, and often inaccessible. We present QUEL-QAL, an open-source Python library designed to streamline and standardize the quantitative analysis of fluorescence images using solid reference targets. The library provides a modular, reproducible workflow that includes region of interest (ROI) detection, statistical analysis, and visualization capabilities. QUEL-QAL supports key metrics such as response linearity, limit of detection, depth sensitivity, and spatial resolution, in alignment with regulatory and academic guidance. Built on widely adopted Python packages, the library is designed to be extensible, enabling users to adapt it to novel target designs and analysis protocols. By promoting transparency, reproducibility, and regulatory alignment, QUEL-QAL offers a foundational tool to support standardized benchmarking and accelerate the development and evaluation of fluorescence imaging systems.2025-04-22T00:03:55Z12 pages, 1 table, 4 figures. Code available: https://github.com/QUEL-Imaging/quel-qal), PyPi: quel-qalEammon A. LittlerEmmanuel A. MannohEthan P. M. LaRochellehttp://arxiv.org/abs/2504.12346v2Mechanical Characterization of Brain Tissue: Experimental Techniques, Human Testing Considerations, and Perspectives2025-04-21T01:25:57ZUnderstanding the mechanical behavior of brain tissue is crucial for advancing both fundamental neuroscience and clinical applications. Yet, accurately measuring these properties remains challenging due to the brain unique mechanical attributes and complex anatomical structures. This review provides a comprehensive overview of commonly used techniques for characterizing brain tissue mechanical properties, covering both invasive methods such as atomic force microscopy, indentation, axial mechanical testing, and oscillatory shear testing and noninvasive approaches like magnetic resonance elastography and ultrasound elastography. Each technique is evaluated in terms of working principles, applicability, representative studies, and experimental limitations. We further summarize existing publications that have used these techniques to measure human brain tissue mechanical properties. With a primary focus on invasive studies, we systematically compare their sample preparation, testing conditions, reported mechanical parameters, and modeling strategies. Key sensitivity factors influencing testing outcomes (e.g., sample size, anatomical location, strain rate, temperature, conditioning, and post-mortem interval) are also discussed. Additionally, selected noninvasive studies are reviewed to assess their potential for in vivo characterization. A comparative discussion between invasive and noninvasive methods, as well as in vivo versus ex vivo testing, is included. This review aims to offer practical guidance for researchers and clinicians in selecting appropriate mechanical testing approaches and contributes a curated dataset to support constitutive modeling of human brain tissue.2025-04-15T18:03:14ZJixin HouKun JiangArunachalam RamanathanAbhishek Saji KumarWei ZhangLin ZhaoTaotao WuRamana PidapartiDajiang ZhuGang LiKenan SongTianming LiuMir Jalil RazaviEllen KuhlXianqiao Wang