https://arxiv.org/api/aGvYsmcJ1MLkTb9J1IpfVUEIuc02026-06-27T09:07:00Z9008138015http://arxiv.org/abs/2410.02632v3Quantification of the Plan Aperture Modulation of Radiotherapy Treatment Plans2025-04-29T18:08:28ZThis study introduces a novel metric, Plan Aperture Modulation (PAM), developed to quantify the modulation of radiotherapy treatment plans. PAM aims to provide a clear geometric interpretation, addressing the limitations of previous complexity metrics and facilitating its integration into treatment planning systems (TPSs) and clinical workflows. The PAM metric was defined as the average fraction of the target area outside the beam aperture, weighted over all control points in a treatment plan. The metric was evaluated in VMAT plans for two sites: prostate with lymph nodes and lung SBRT. Plans with varying complexities were generated using the Eclipse TPS, and PAM was compared to established metrics, including Plan Modulation (PM), Modulation Complexity Score (MCS), and monitor units per Gray (MU/Gy). The relationship between PAM and the Modulation Factor (MF), which quantifies the increase in MUs due to plan modulation, was also investigated. PAM provided a more intuitive assessment of plan modulation compared to the other metrics, and was validated across different delivery systems, such as C-arm linacs and Halcyon systems. The metric outperformed the previous metrics, indicated a zero modulation for Dynamic Conformal Arc plans, and was independent of confounding variables, such as treatment technique, beam energy, delivery system, and patient anatomy. Derived equations enabled the calculation of MF based on PAM, allowing for a robust quantification of plan modulation. PAM is a robust and intuitive metric for quantifying modulation in radiotherapy plans. It overcomes the limitations of previous metrics and can be readily implemented in TPSs to control plan modulation during optimization and for reporting. PAM is a promising tool for improving treatment planning workflows and for comparing and benchmarking radiotherapy plans in multi-institutional studies, clinical trials, and audits.2024-10-03T16:15:15ZVictor HernandezIñigo Lara-AristimuñoRuben AbellaJordi Saez10.1002/mp.70144http://arxiv.org/abs/2504.20874v1Diagnostic performance of echocardiography in detecting and differentiating cardiac amyloidosis: a meta-analysis2025-04-29T15:44:30ZAims: This meta-analysis aimed to evaluate the diagnostic performance of echocardiographic parameters for cardiac amyloidosis (CA), with a focus on subtype stratification and comparisons with healthy controls. Methods and Results: A comprehensive search identified 26 studies published before February 2025, encompassing 3,802 patients. Compared to healthy individuals, CA patients demonstrated significant echocardiographic abnormalities, including reduced left ventricular ejection fraction (LVEF; WMD = -10.65, 95% CI: [-11.84, -9.46]), increased left atrial volume index (WMD = +15.87, 95% CI: [14.35, 17.38]), and thickened posterior wall (WMD = +5.14, 95% CI: [4.85, 5.42]). Subtype analyses revealed that transthyretin cardiac amyloidosis (ATTR-CA) was associated with more pronounced systolic dysfunction than light-chain cardiac amyloidosis (AL-CA), evidenced by lower global longitudinal strain (WMD = -2.02, 95% CI: [-2.66, -1.37]), reduced LVEF (WMD = -5.31, 95% CI: [-6.63, -3.99]), and diminished tricuspid annular plane systolic excursion (WMD = -1.59, 95% CI: [-2.23, -0.95]). Additionally, ATTR-CA patients exhibited greater ventricular wall thickening in both posterior wall (WMD = +1.87, 95% CI: [1.51, 2.23]) and interventricular septum (WMD = +2.24, 95% CI: [1.85, 2.63]). Conclusion: Echocardiography plays a pivotal role in diagnosing CA and distinguishing between AL-CA and ATTR-CA. Key indices such as LVEF and global longitudinal strain are especially valuable for early detection, while subtype-specific patterns highlight distinct underlying pathophysiologies, offering guidance for tailored diagnostic and therapeutic strategies.2025-04-29T15:44:30ZZihang ZhangYunjie ChenYuanzhou CaoXinyi XieKangming JiChuang YangLijun Qianhttp://arxiv.org/abs/2504.20440v1Consensus Recommendations for Hyperpolarized [1-13C]pyruvate MRI Multi-center Human Studies2025-04-29T05:29:48ZMagnetic resonance imaging of hyperpolarized (HP) [1-13C]pyruvate allows in-vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. Consensus on best practice for multi-center studies is required to develop clinical applications. This paper presents the results of a 2-round formal consensus building exercise carried out by experts with HP [1-13C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data-analysis; with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-13C]pyruvate MRI.
Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering 'HP 13C-Pyruvate Preparation', 'MRI System Setup, Calibration, and Phantoms', 'Acquisition and Reconstruction', and 'Data Analysis and Quantification'.
Consensus was present across categories, examples include that: (i) different HP pyruvate preparation methods could be used in human studies, but that the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and that the same field strength must be used, but that the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve (AUC) values and metabolite AUC were the preferred metabolism metrics.
The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.2025-04-29T05:29:48ZShonit PunwaniPeder EZ LarsonChristoffer LaustsenJan VanderMeulenJan Henrik Ardenkjær-LarsenAdam W. AutryJames A. BanksonJenna BernardRobert BokLotte Bonde BertelsenJenny CheAlbert P. ChenRafat ChowdhuryArnaud CommentCharles H. CunninghamDuy DangFerdia A GallagherAdam GauntYangcan GongJeremy W. GordonAshley GrimmerJames GristEsben Søvsø Szocska HansenMathilde Hauge LercheRichard L. HeskethJan-Bernd HoevenerChing-Yi HsiehKayvan R. KeshariSebastian KozerkeTitus LanzDirk MayerMary McLeanJae Mo ParkJim SlaterDamian TylerJean-Luc VanderheydenDaniel VigneronCornelius von MorzeDuan XuFulvio ZaccagnaVlad Zahathe HP 13C MRI Consensus Grouphttp://arxiv.org/abs/2504.20226v1Joint Range-modulator and Spot Optimization for Bragg-peak Proton FLASH Radiotherapy2025-04-28T19:50:51ZBackground: Ultra-high-dose-rate (UHDR) radiation therapy has demonstrated promising potential in reducing toxicity to organs-at-risk (OARs). Proton therapy is uniquely positioned to deliver UHDR by leveraging the Bragg peak in conjunction with patient-specific range modulators (PSRMs) to generate a spread-out Bragg peak (SOBP). Existing proton FLASH (pFLASH) planning typically involves (1) generating a multi-energy IMPT plan for spot weights and (2) converting it to single-energy delivery via PSRM optimization. However, the intrinsic coupling between spot weight distribution and PSRM design has not been fully investigated. Purpose: This work proposes Joint Range-Modulator and Spot Optimization (JRSO) that simultaneously optimizes the PSRM and spot weights to improve the plan quality of conformal pFLASH therapy. Methods: Unlike the conventional method, JRSO does not require a one-to-one correspondence between beam spots and PSRM pins. To achieve better plan quality, starting from an initial solution derived from a conventional IMPT plan, JRSO alternatively updates the PSRM design and spot weights. This process progressively refines both parameters while ensuring compliance with practical delivery constraints, such as the minimum monitor-unit (MMU) requirement. Results: JRSO obtained improved plan quality compared to the conventional method. For example, in a head-and-neck (HN) case, JRSO lowered the maximum target dose from 117.6% to 107.1%, improved the conformity index from 0.74 to 0.87, and decreased the region-of-interest (ROI) effective dose from 6.50 Gy to 6.10 Gy. Conclusion: A new optimization method JRSO is proposed for conformal pFLASH radiotherapy. It outperforms the conventional approach and may extend the applicability of PSRM to more complex clinical scenarios, particularly those involving misalignments between beam spots and pins.2025-04-28T19:50:51Z27 pages, 4 figuresJiayue HanYa-Nan ZhuAoxiang WangWangyao LiYuting LinHao Gaohttp://arxiv.org/abs/2406.17895v2On the mechanics of inhaled bronchial transmission of pathogenic microdroplets generated from the upper respiratory tract, with implications for infection onset2025-04-28T16:17:18ZCould the microdroplets formed by viscoelastic stretching and break-up of mucosal liquids in the upper respiratory tract (URT), when inhaled further downwind, explain the brisk pace at which deep lung infections emerge following onset of initial infection at the URT? While it is well-established that particulates inhaled from outside can possibly penetrate to the lower airway only if they are < 5 microns, the fate of particulates (many > 5-microns in diameter) sheared away from the intra-URT mucosa during inhalation remains an open question. These particulates predominantly originate at the nasopharynx, oropharynx, and laryngeal chamber with the vocal folds. To resolve the posed question, this study considers a CT-based 3D anatomical airway reconstruction and isolates the tract from the laryngeal vocal fold region, mapping the entire tracheal cavity and concluding at generation 2 of the tracheobronchial tree. Through the delineated geometry, airflow simulation is conducted using the LES scheme to replicate relaxed inhalation at 15 L/min. Against the ambient air flux, numerical experiments have been performed to monitor the transport of liquid particulates with diameters 1-30 microns, bearing physical properties akin to aerosolized mucus with embedded virions. The full-scale numerical transmission trends to the lower airway were found consistent with the findings from a reduced-order mathematical model that conceptualized the impact of intra-airway vortex instabilities on local particle transport through point vortex idealization in an anatomy-guided 2D potential flow domain. The results collectively demonstrate markedly elevated trends of deep lung penetration by the URT-derived particulates, even if they are as large as 10- and 15 microns. The high viral load carried by such droplets to the bronchial spaces could mechanistically explain the accelerated seeding of infection in the lungs.2024-06-25T19:07:22Z18 pages, 8 figures, 2 tablesSaikat Basuhttp://arxiv.org/abs/2504.19927v1Dependence of the Radical Dynamics on the Beam Temporal Profile in FLASH Radiotherapy2025-04-28T16:01:26ZPurpose: This study aims to investigate the impact of the beam temporal profile on the radical dynamics and inter-track interactions of FLASH radiotherapy, supporting parameter optimization for the equipment development and clinical implementation. Methods: MonteCarlo simulations based on the IRT method were performed to analyze the dynamics after irradiation, including single-pulse or multi-pulses irradiation, pulse repetition rate, width and dose. The physicochemical experiments were performed to measure the eaq-lifetimes for validation. The generation and recombination of OH and eaq-radicals were recorded under 6 MeV electron irradiation with varying beam temporal profiles. The radial distributions of the radicals were statistically analyzed, and the corresponding LETd and LETt were calculated. The inter-track interactions were assessed through a mathematical model. Results: The spatial distribution and temporal evolution of radicals were significantly affected by the beam time profiles. Compared with multi-pulses irradiation, single-pulse mode with a width less than 1/10 of the radical lifetime, a repetition interval longer than the radical lifetime, and a dose exceeding 1 Gy/pulse can lead to radicals rapid consumption, reducing the residual content. Instantaneous high dose rates induced radical tracks overlaps. When the single-pulse dose exceeded 1 Gy, the overlap probability approached 100%, aligning with the threshold for radical instantaneous combination. Conclusion: Under a low-duty cycle and high instantaneous dose-rate time profile, the radicals were rapidly consumed through track overlap hence reduced damage to normal tissues, inducing FLASH effect. The optimized time profile can be used to guide the development of equipment and parameter settings in clinical practice to maximize the FLASH effect, such as the laser accelerators and superconducting photocathode guns.2025-04-28T16:01:26Z18 pagesJianhan SunXianghui KongJianfeng LvXiaodong LiuJinghui WangChen LinTian LiYibao ZhangSenlin Huang10.1088/1361-6560/ae37c3http://arxiv.org/abs/2501.04419v2Extending the time-over-threshold calibration of Timepix3 for spatial-resolved ion spectroscopy2025-04-28T14:32:07ZHybrid pixel detectors have a well-established array of applications ranging from particle physics to life sciences. The small dimensions of Timepix3 as well as its relatively low energetic expenses make it an intriguing option additionally for ion detection in nuclear physics experiments, as it reveals simultaneously precise temporal, spatial and energetic properties of recorded events from nuclear reactions. Currently, a limiting factor is the electronics behavior at high input charge resulting in improper energy determination of incident heavier ions. While the low-energy per-pixel calibration of Timepix3 is normally performed with the use of photons of up to 60 keV, the characteristic linear range permits a correct extrapolation up to only 150 keV/pixel. We developed a global per-pixel energy correction method involving the use of short-ranged accelerated ions and spectroscopic alpha sources, to suitably extend the energy determination capability of Timepix3 for nuclear ion spectroscopy experiments, where spatial and temporal precision of recorded events are equally crucial. It was found that upon applying this correction, the reliable per-pixel energy range has been increased from the original 150 keV to at least 1.1 MeV, while maintaining the relative energy resolution to better than 2.5% for stopped protons of up to 1.9 MeV and better than 3.1% for alpha particles of 5.5 MeV. Furthermore, to demonstrate the spatial resolution of Timepix3 detectors with silicon sensors, we present alpha-radiography measurements from which we extract the modulation transfer function (MTF) and produce real-world biological sample images.2025-01-08T11:07:54ZJINST 20 P05040 (2025)Radu-Emanuel MihaiBenedikt BergmannPetr Smolyanskiy10.1088/1748-0221/20/05/P05040http://arxiv.org/abs/2505.02843v1Physical foundations for trustworthy medical imaging: a review for artificial intelligence researchers2025-04-28T09:35:00ZArtificial intelligence in medical imaging has seen unprecedented growth in the last years, due to rapid advances in deep learning and computing resources. Applications cover the full range of existing medical imaging modalities, with unique characteristics driven by the physics of each technique. Yet, artificial intelligence professionals entering the field, and even experienced developers, often lack a comprehensive understanding of the physical principles underlying medical image acquisition, which hinders their ability to fully leverage its potential. The integration of physics knowledge into artificial intelligence algorithms enhances their trustworthiness and robustness in medical imaging, especially in scenarios with limited data availability. In this work, we review the fundamentals of physics in medical images and their impact on the latest advances in artificial intelligence, particularly, in generative models and reconstruction algorithms. Finally, we explore the integration of physics knowledge into physics-inspired machine learning models, which leverage physics-based constraints to enhance the learning of medical imaging features.2025-04-28T09:35:00Z17 pages, 2 figuresMiriam CoboDavid Corral FontechaWilson SilvaLara Lloret Iglesiashttp://arxiv.org/abs/2504.19401v1Innovative Integration of 4D Cardiovascular Reconstruction and Hologram: A New Visualization Tool for Coronary Artery Bypass Grafting Planning2025-04-28T00:56:06ZBackground: Coronary artery bypass grafting (CABG) planning requires advanced spatial visualization and consideration of coronary artery depth, calcification, and pericardial adhesions. Objective: To develop and evaluate a dynamic cardiovascular holographic visualization tool for preoperative CABG planning. Methods: Using 4D cardiac computed tomography angiography data from 14 CABG candidates, we developed a semi-automated workflow for time-resolved segmentation of cardiac structures, epicardial adipose tissue (EAT), and coronary arteries with calcium scoring. The workflow incorporated methods for cardiac segmentation, coronary calcification quantification, visualization of coronary depth within EAT, and pericardial adhesion assessment through motion analysis. Dynamic cardiovascular holograms were displayed using the Looking Glass platform. Thirteen cardiac surgeons evaluated the tool using a Likert scale. Additionally, pericardial adhesion scores from holograms of 21 patients (including seven undergoing secondary cardiac surgeries) were compared with intraoperative findings. Results: Surgeons rated the visualization tool highly for preoperative planning utility (mean Likert score: 4.57/5.0). Hologram-based pericardial adhesion scoring strongly correlated with intraoperative findings (r=0.786, P<0.001). Conclusion: This study establishes a visualization framework for CABG planning that produces clinically relevant dynamic holograms from patient-specific data, with clinical feedback confirming its effectiveness for preoperative planning.2025-04-28T00:56:06Z35 pages, 9 figuresJMIR Med Inform 13, e72237 (2025)Shuo WangTong RenNan ChengLi ZhangRong Wang10.2196/72237http://arxiv.org/abs/2503.01576v2MRI super-resolution reconstruction using efficient diffusion probabilistic model with residual shifting2025-04-26T17:46:19ZObjective:This study introduces a residual error-shifting mechanism that drastically reduces sampling steps while preserving critical anatomical details, thus accelerating MRI reconstruction. Approach:We propose a novel diffusion-based SR framework called Res-SRDiff, which integrates residual error shifting into the forward diffusion process. This enables efficient HR image reconstruction by aligning the degraded HR and LR distributions.We evaluated Res-SRDiff on ultra-high-field brain T1 MP2RAGE maps and T2-weighted prostate images, comparing it with Bicubic, Pix2pix, CycleGAN, and a conventional denoising diffusion probabilistic model with vision transformer backbone (TM-DDPM), using quantitative metrics such as peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), gradient magnitude similarity deviation (GMSD), and learned perceptual image patch similarity (LPIPS). Main results: Res-SRDiff significantly outperformed all comparative methods in terms of PSNR, SSIM, and GMSD across both datasets, with statistically significant improvements (p-values<<0.05). The model achieved high-fidelity image restoration with only four sampling steps, drastically reducing computational time to under one second per slice, which is substantially faster than conventional TM-DDPM with around 20 seconds per slice. Qualitative analyses further demonstrated that Res-SRDiff effectively preserved fine anatomical details and lesion morphology in both brain and pelvic MRI images. Significance: Our findings show that Res-SRDiff is an efficient and accurate MRI SR method, markedly improving computational efficiency and image quality. Integrating residual error shifting into the diffusion process allows for rapid and robust HR image reconstruction, enhancing clinical MRI workflows and advancing medical imaging research. The source at:https://github.com/mosaf/Res-SRDiff2025-03-03T14:15:08ZMojtaba SafariShansong WangZach EidexQiang LiErik H. MiddlebrooksDavid S. YuXiaofeng Yang10.1088/1361-6560/ade049http://arxiv.org/abs/2504.18968v1HeartSimSage: Attention-Enhanced Graph Neural Networks for Accelerating Cardiac Mechanics Modeling2025-04-26T16:31:12ZFinite element analysis (FEA) forms the cornerstone of modeling cardiac biomechanics but is computationally expensive, limiting its clinical application for digital twin creation, which often requires tens to hundreds of simulations to estimate tissue parameters. We developed an attention-enhanced graph neural network (GNN)-based FEA emulator, HeartSimSage, to rapidly predict passive biventricular myocardial displacements from patient-specific geometries, chamber pressures, and material properties. HeartSimSage addresses the limitations of current emulators by effectively handling diverse three-dimensional (3D) biventricular geometries, mesh topologies, fiber directions, structurally based constitutive models, and physiological boundary conditions. It supports flexible mesh structures with variable node counts, orderings, and element connectivity. To optimize information propagation, we designed a neighboring connection strategy inspired by Graph Sample and Aggregate (GraphSAGE) that prioritizes local interactions while maintaining mid-to-long-range dependencies. We further incorporated Laplace-Dirichlet solutions for enhanced spatial encoding and employed subset-based training for improved efficiency. By integrating an attention mechanism, HeartSimSage adaptively weighs neighbor contributions and filters irrelevant information, enhancing prediction accuracy. HeartSimSage achieves approximately 13,000x speedup on GPU and 190x on CPU compared to traditional FEA, while maintaining a nominal averaged error of 0.13% +- 0.12% in predicting biventricular displacements. We validated our model using a published left ventricle dataset and conducted sensitivity analyses on hyperparameters, neighboring strategies, and the attention mechanism.2025-04-26T16:31:12ZLei ShiYurui ChenVijay Vedulahttp://arxiv.org/abs/2504.18343v1Evaluation of the Automatic Classifier AutoSense Sky OS for Pediatric Cochlear Implant Users using a Virtual Classroom Environment2025-04-25T13:32:14ZThis study evaluated whether AutoSense Sky OS, an automatic classifier used in pediatric Advanced Bionics cochlear implants (CIs), improves speech intelligibility from the front without significantly impairing spatial awareness (i.e., sound detection and identification from all directions), with the main focus on the classroom situation. A double-blind crossover study was conducted with 12 pediatric CI users aged 7-16 years. Participants tested two settings: one with AutoSense Sky OS activated and the other with an omnidirectional microphone mode. Speech intelligibility from the front and spatial awareness were assessed in a virtual classroom environment using a Virtual Reality headset and a 12-loudspeaker array. Participants also rated the performance of each setting during a take-home period. A technical evaluation revealed that AutoSense Sky OS activated its directional microphone mode in the virtual classroom, and during the listening test this significantly improved speech intelligibility from the front while significantly reducing spatial awareness. While not all participants reported noticeable differences between settings in daily life, 8 out of 12 children preferred "AutoSense on", perceiving improved speech intelligibility in noisy environments. Conversely, some participants preferred "AutoSense off" due to poorer localization and speech intelligibility from behind with "AutoSense on". In conclusion, the automatic classifier provided improved speech understanding in noisy conditions such as a classroom, at the cost of a slightly reduced spatial awareness. The preference for AutoSense Sky OS among CI children and their parents appears to be a matter of individual trade-offs between improved speech intelligibility in noisy conditions and reduced spatial awareness.2025-04-25T13:32:14Z31 pages, 11 figuresMaartje M. E. HendrikseAndré GoedegebureKars R. TjepkemaJantien L. Vroegop10.1016/j.heares.2025.109414http://arxiv.org/abs/2312.03116v2Deformable Registration of MRA and 4D Flow Images to Facilitate Accurate Estimation of Flow Properties within Blood Vessels2025-04-25T12:42:06ZA method is presented for the registration of MRA and 4D Flow images, with the goal of calculating blood flow properties using both modalities simultaneously. In particular, the method produces an alignment of segmentations of vessel networks, from MRA images, with the blood velocity field within those networks, from the corresponding 4D Flow images. The alignment procedure is driven by the registration of centerlines of vessels extracted from the two modalities. Our approach is robust to noise, small deformations, and partial omissions of vessel surfaces and/or blood velocities. The alignment procedure is tested on 7 patient data sets acquired at Texas Children's Hospital. The quality of the resulting alignment is assessed by (i) an illustration of the aligned and unaligned surface segmentations for a sample patient, (ii) histograms of distances between centerline networks, and (iii) graphs of estimated blood flow. For each of the 7 analyzed data sets, medians of the distance histograms decreased an average of 83.5%, and the estimated blood flow increased significantly as a result of the alignment procedure.2023-12-05T20:24:39ZDan LiorCraig G. RusinJustin WeigandKristina V. MontezYimo WangSilvana MolossiDaniel J. PennyCharles Puelzhttp://arxiv.org/abs/2410.20828v3Projection-based Reduced Order Modelling for Unsteady Parametrized Optimal Control Problems in 3D Cardiovascular Flows2025-04-25T09:23:34ZThis paper presents a projection-based reduced order modelling (ROM) framework for unsteady parametrized optimal control problems (OCP$_{(μ)}$s) arising from cardiovascular (CV) applications. In real-life scenarios, accurately defining outflow boundary conditions in patient-specific models poses significant challenges due to complex vascular morphologies, physiological conditions, and high computational demands. These challenges make it difficult to compute realistic and reliable CV hemodynamics by incorporating clinical data such as 4D magnetic resonance imaging. To address these challenges, we focus on controlling the outflow boundary conditions to optimize CV flow dynamics and minimize the discrepancy between target and computed flow velocity profiles. The fluid flow is governed by unsteady Navier--Stokes equations with physical parametric dependence, i.e. the Reynolds number. Numerical solutions of OCP$_{(μ)}$s require substantial computational resources, highlighting the need for robust and efficient ROMs to perform real-time and many-query simulations. Here, we aim at investigating the performance of a projection-based reduction technique that relies on the offline-online paradigm, enabling significant computational cost savings. The Galerkin finite element method is used to compute the high-fidelity solutions in the offline phase. We implemented a nested-proper orthogonal decomposition (nested-POD) for fast simulation of OCP$_{(μ)}$s that encompasses two stages: temporal compression for reducing dimensionality in time, followed by parametric-space compression on the precomputed POD modes. We tested the efficacy of the methodology on vascular models, namely an idealized bifurcation geometry and a patient-specific coronary artery bypass graft, incorporating stress control at the outflow boundary, observing consistent speed-up with respect to high-fidelity strategies.2024-10-28T08:26:39ZSurabhi RathorePasquale Claudio AfricaFrancesco BallarinFederico PichiMichele GirfoglioGianluigi Rozzahttp://arxiv.org/abs/2504.18101v1A Noise-Robust Model-Based Approach to T-Wave Amplitude Measurement and Alternans Detection2025-04-25T06:01:07ZT-wave alternans (TWA) is a potential marker for sudden cardiac death, but its reliable analysis is often constrained to noise-free environments, limiting its utility in real-world settings. We explore model-based T-wave estimation to mitigate the impact of noise on TWA level. Detection was performed using a previous surrogate-based method as a benchmark and a new method based on a Markov model state transition matrix (STM). These were combined with a Modified Moving Average (MMA) method and polynomial T-wave modeling to enhance noise robustness. Methods were tested across a wide range of signal-to-noise ratios (SNRs), from -5 to 30 dB, and different noise types: baseline wander (BW), muscle artifacts (MA), electrode movement (EM), and respiratory modulation. Synthetic ECGs with known TWA levels were used: 0 uV for TWA-free and 30-72 uV for TWA-present signals. T-wave modeling improved estimation accuracy under noisy conditions. With EM noise at SNRs of -5 and 5 dB, mean absolute error (MAE) dropped from 62 to 49 uV and 27 to 25 uV, respectively (Mann-Whitney-U test, p < 0.05) with modeling applied. Similar improvements were seen with MA noise: MAE dropped from 100 to 70 uV and 26 to 23 uV. In detection, the STM method achieved an F1-score of 0.92, outperforming the surrogate-based method (F1 = 0.81), though both struggled under EM noise at -5 dB. Importantly, beyond SNR, detection performance depended on the number of beats analyzed. These findings show that combining model-based estimation with STM detection significantly improves TWA analysis under noise, supporting its application in ambulatory and wearable ECG monitoring.2025-04-25T06:01:07Z11 pages, 8 figuresZuzana KoscovaAmit ShahAli Bahrami RadQiao LiGari D CliffordReza Sameni