https://arxiv.org/api/b1EwPDlhPE7ZR+oWOSQY8xAUUPk2026-06-27T08:08:22Z9008136515http://arxiv.org/abs/2411.00165v3Accurate and Efficient Cardiac Digital Twin from surface ECGs: Insights into Identifiability of Ventricular Conduction System2025-05-02T14:14:59ZDigital twins for cardiac electrophysiology are an enabling technology for precision cardiology. Current forward models are advanced enough to simulate the cardiac electric activity under different pathophysiological conditions and accurately replicate clinical signals like torso electrocardiograms (ECGs). In this work, we address the challenge of matching subject-specific QRS complexes using anatomically accurate, physiologically grounded cardiac digital twins. By fitting the initial conditions of a cardiac propagation model, our non-invasive method predicts activation patterns during sinus rhythm. For the first time, we demonstrate that distinct activation maps can generate identical surface ECGs. To address this non-uniqueness, we introduce a physiological prior based on the distribution of Purkinje-muscle junctions. Additionally, we develop a digital twin ensemble for probabilistic inference of cardiac activation. Our approach marks a significant advancement in the calibration of cardiac digital twins and enhances their credibility for clinical application.2024-10-31T19:16:00Z27 pages, 11 figuresThomas GranditsKarli GilletteGernot PlankSimone Pezzutohttp://arxiv.org/abs/2505.01165v1Helium Range Viability for Online Range Probing in Mixed Carbon-Helium Beams2025-05-02T10:14:38ZBackground: Recently, mixed carbon-helium beams were proposed for range verification in carbon ion therapy: Helium, with three times the range of carbon, serves as an on-line range probe, and is mixed into a therapeutic carbon beam. Purpose: Treatment monitoring is of special interest for lung cancer therapy, however the helium range might not always be sufficient to exit the patient distally. Therefore mixed beam use cases of several patient sites are considered. Methods: An extension to the open-source planning toolkit, matRad allows for calculation and optimization of mixed beam treatment plans. The use of the mixed beam method in 15 patients with lung cancer, as well as in a prostate and liver case, for various potential beam configurations was investigated. Planning strategies to optimize the residual helium range considering the sensitive energy range of the imaging detector were developed. A strategy involves adding helium to energies whose range is sufficient. Another one is to use range shifters to increase the helium energy and thus range. Results: In most patient cases, the residual helium range of at least one spot is too low. All investigated planning strategies can be used to ensure a high enough helium range while still keeping a low helium dose and a satisfactory total mixed carbon-helium beam dose. The use of range shifters allows for the detection of more spots. Conclusion: The mixed beam method shows promising results for online motioning. The use of range shifters ensures a high enough helium range and more detectable spots, allowing for a wider-spread application.2025-05-02T10:14:38ZMed Phys. 2025;52:e70194Jennifer J. HardtAlexander A. PryanichnikovOliver JäkelJoao SecoNiklas Wahl10.1002/mp.70194http://arxiv.org/abs/2504.18379v2The Foundation for Developing an Exoskeleton for the Rehabilitation of Temporomandibular Disorders2025-05-02T09:55:18ZTemporomandibular disorders affect a significant portion of the population, often causing pain and restricted jaw movement. Physiotherapy with active jaw exoskeletons seems to be a promising treatment approach. However, there has been limited progress in this area, with only a few studies published. The lack of detailed simulations and biomechanical jaw models in these papers impedes the design and validation of such devices. Thus, this work presents an open-source and extendable jaw model framework to support the development of jaw exoskeletons for TMD rehabilitation. The framework includes three model variants with varying complexity: a rigid body model with point-on-surface constraints, a rigid body model with mesh geometry constraints, and a hybrid model combining rigid dynamics with finite element methods. Model customization is facilitated through JSON configuration files, requiring minimal programming expertise. The framework was evaluated using experimental kinematic data from a single participant, with muscle excitations computed via PID controllers tuned through global optimization. The models successfully reproduced jaw movements without prior individualization, demonstrating their suitability for prototyping and studying exoskeleton behavior. The basic models are ideal for rapid prototyping, while the hybrid model provides insights into the effects of exoskeletons on the masticatory system. This framework establishes a foundation for advancing jaw exoskeleton development, with future work focusing on patient-specific modeling, improved anatomical detail, and tools for exoskeleton control and design. The framework code is publicly available and can be found at https://github.com/paulotto/exosim.2025-04-25T14:25:36Z7 pages, 3 figures, 1 table, GitHub: https://github.com/paulotto/exosim2025 IEEE International Conference on Simulation, Modeling, and Programming for Autonomous Robots (SIMPAR), Palermo, Italy, 2025, https://ieeexplore.ieee.org/document/10979121Paul-Otto MüllerOskar von Stryk10.1109/SIMPAR62925.2025.10979121http://arxiv.org/abs/2405.10592v3Secondary spectrum after shieldings in x-ray rooms2025-05-01T20:17:30ZBackground: Calculating the characteristics of radiation emerging from radiation shielding to determine the level of safety in protected areas has been a widely studied topic in Radiation Protection due to its importance for the protection of the public and professionals. Methods: This work provides spatial distributions of energy spectra of emergent photons after shielding barriers. These distributions are obtained through Monte Carlo simulations using monoenergetic pencil photon beams incident on shielding barriers of different materials and thicknesses. The obtained results are applied to calculate the spectra of transmitted radiation in cases of polyenergetic beams similar to those encountered in clinical practice. Results: The significant contribution of secondary radiation in the radiation found behind shields is demonstrated across a wide range of energies, barrier thicknesses and barrier materials. Conclusion: It is shown that characterizing shields using their response to monoenergetic pencil beams provides a useful tool for characterizing radiation behind shields in a wide range of practical situations.2024-05-17T07:33:09ZAntonio González-Lópezhttp://arxiv.org/abs/2505.00670v1TumorTwin: A python framework for patient-specific digital twins in oncology2025-05-01T17:20:20ZBackground: Advances in the theory and methods of computational oncology have enabled accurate characterization and prediction of tumor growth and treatment response on a patient-specific basis. This capability can be integrated into a digital twin framework in which bi-directional data-flow between the physical tumor and the digital tumor facilitate dynamic model re-calibration, uncertainty quantification, and clinical decision-support via recommendation of optimal therapeutic interventions. However, many digital twin frameworks rely on bespoke implementations tailored to each disease site, modeling choice, and algorithmic implementation.
Findings: We present TumorTwin, a modular software framework for initializing, updating, and leveraging patient-specific cancer tumor digital twins. TumorTwin is publicly available as a Python package, with associated documentation, datasets, and tutorials. Novel contributions include the development of a patient-data structure adaptable to different disease sites, a modular architecture to enable the composition of different data, model, solver, and optimization objects, and CPU- or GPU-parallelized implementations of forward model solves and gradient computations. We demonstrate the functionality of TumorTwin via an in silico dataset of high-grade glioma growth and response to radiation therapy.
Conclusions: The TumorTwin framework enables rapid prototyping and testing of image-guided oncology digital twins. This allows researchers to systematically investigate different models, algorithms, disease sites, or treatment decisions while leveraging robust numerical and computational infrastructure.2025-05-01T17:20:20ZMichael KapteynAnirban ChaudhuriErnesto A. B. F. LimaGraham PashRafael BravoKaren WillcoxThomas E. YankeelovDavid A. Hormuthhttp://arxiv.org/abs/2505.00643v1Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI2025-05-01T16:31:52ZReal-time (RT) dynamic MRI plays a vital role in capturing rapid physiological processes, offering unique insights into organ motion and function. Among these applications, RT cine MRI is particularly important for functional assessment of the heart with high temporal resolution. RT imaging enables free-breathing, ungated imaging of cardiac motion, making it a crucial alternative for patients who cannot tolerate conventional breath-hold, ECG-gated acquisitions. However, achieving high acceleration rates in RT cine MRI is challenging due to aliasing artifacts from extra-cardiac tissues, particularly at high undersampling factors. In this study, we propose a novel outer volume removal (OVR) method to address this challenge by eliminating aliasing contributions from non-cardiac regions in a post-processing framework. Our approach estimates the outer volume signal for each timeframe using composite temporal images from time-interleaved undersampling patterns, which inherently contain pseudo-periodic ghosting artifacts. A deep learning (DL) model is trained to identify and remove these artifacts, producing a clean outer volume estimate that is subsequently subtracted from the corresponding k-space data. The final reconstruction is performed with a physics-driven DL (PD-DL) method trained using an OVR-specific loss function to restore high spatio-temporal resolution images. Experimental results show that the proposed method at high accelerations achieves image quality that is visually comparable to clinical baseline images, while outperforming conventional reconstruction techniques, both qualitatively and quantitatively. The proposed approach provides a practical and effective solution for artifact reduction in RT cine MRI without requiring acquisition modifications, offering a pathway to higher acceleration rates while preserving diagnostic quality.2025-05-01T16:31:52ZMerve GülleSebastian WeingärtnerMehmet Akçakayahttp://arxiv.org/abs/2504.21765v1Evaluation of In Vivo Subject-Specific Mechanical Modeling of the Optic Nerve Head for Robust Assessment of Ocular Mechanics2025-04-30T16:05:50ZTo establish the tissue regions necessary to accurately represent the mechanics of the optic nerve head (ONH), imaging data of the ONH from 2 healthy subjects were used to create in vivo subject-specific eye mechanical models considering distinct properties for all major ocular tissues. Tests were performed to evaluate the effect of the material properties and the inclusion of these tissues on the mechanics of the lamina cribrosa (LC), retina, and optic nerve. Then, the LC mechanical response due to variations in intraocular and intracranial pressures was evaluated to validate the modeling approach. The sclera stiffness has the largest impact on the mechanics of the LC, retina, and optic nerve, while Bruchs membrane has a negligible effect on these tissues response. The validation tests showed increased LC strain with increased pressure and highest strains in the inferior and temporal subregion, as seen in literature studies. Consequently, accurate ONH mechanical representation can be obtained by only including those tissue regions identified as necessary.2025-04-30T16:05:50Z23 pages, 12 figures, 1 tableSoumaya OuhsousouLucy Q. ShenChhavi SainiAmin PourasgharMengyu WangJohn C. Brighamhttp://arxiv.org/abs/2504.21743v1Obstructive Sleep Apnea Characterization: A Multimodal Cross-Recurrence-Based Approach for Investigating Atrial Fibrillation2025-04-30T15:39:07ZObstructive sleep apnea (OSA) is believed to contribute significantly to atrial fibrillation (AF) development in certain patients. Recent studies indicate a rising risk of AF with increasing OSA severity. However, the commonly used apnea-hypopnea index in clinical practice may not adequately account for the potential cardiovascular risks associated with OSA. (1) Objective: to propose and explore a novel method for assessing OSA severity considering potential connection to cardiac arrhythmias. (2) Method: the approach utilizes cross-recurrence features to characterize OSA and AF by considering the relationships among oxygen desaturation, pulse arrival time, and heart-beat intervals. Multinomial logistic regression models were trained to predict four levels of OSA severity and four groups related to heart rhythm issues. The rank biserial correlation coefficient, rrb, was used to estimate effect size for statistical analysis. The investigation was conducted using the MESA database, which includes polysomnography data from 2055 subjects. (3) Results: a derived cross-recurrence-based index showed a significant association with a higher OSA severity (p < 0.01) and the presence of AF (p < 0.01). Additionally, the proposed index had a significantly larger effect, rrb, than the conventional apnea-hypopnea index in differentiating increasingly severe heart rhythm issue groups: 0.14 > 0.06, 0.33 > 0.10, and 0.41 > 0.07. (4) Significance: the proposed method holds relevance as a supplementary diagnostic tool for assessing the authentic state of sleep apnea in clinical practice.2025-04-30T15:39:07ZAlready published in the IEEE Journal of Biomedical and Health Informatics (JBHI) under a Creative Commons License CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Accepted 11 July 2024. Date of current version 4 October 2024 (13 pages, 11 figures, 2 tables). Volume: 28, Issue: 10, Pages: 6155 - 6167. Link to the published paper: https://ieeexplore.ieee.org/document/10601325Mantas RinkevičiusJesús LázaroEduardo GilPablo LagunaPeter H. CharltonRaquel BailónVaidotas Marozas10.1109/JBHI.2024.3428845http://arxiv.org/abs/2410.12533v2Imaging neutrons with a position-sensitive monolithic CLYC detector2025-04-30T12:37:06ZIn this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $γ$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at simultaneously obtaining information about the spatial origin of \g-ray and neutron sources. We first investigated the performance of large 50$\times$50~mm$^{2}$ monolithic CLYC crystals coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95\% $^{6}$Li-enriched CLYC detectors coupled to an array of 8$\times$8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. Energy resolution ranging from 6-8\% for the $^{137}$Cs peak and a figure of merit of 3-4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to $γ$-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5~mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.2024-10-16T13:10:29Z14 pages, 15 Figures, submitted to NIM-AJ. Lerendegui-MarcoG. CisternaJ. HallamV. Babiano-SuárezJ. Balibrea-CorreaD. CalvoI. LadarescuG. de la FuenteB. GameiroA. Sanchis-MoltóP. Torres-SánchezC. Domingo-Pardohttp://arxiv.org/abs/2504.21537v1The role of dendritic spines in water exchange measurements with diffusion MRI: Double Diffusion Encoding and free-waveform MRI2025-04-30T11:34:44ZTime-dependent diffusion MRI enables the estimation of water exchange rates in vivo, yet reported values in grey matter remain inconsistent. While most studies attribute these estimates to membrane permeability, non-permeative geometric exchange has also been proposed. The present study investigates the contribution of geometric exchange between dendritic spines and shafts to diffusion MRI-derived exchange estimates. Monte Carlo simulations were performed in synthetic dendrites with varying spine morphology, density, and membrane permeability. Diffusion-weighted signals were generated using multiple protocols - including single diffusion encoding, double diffusion encoding, and free waveforms - and were analysed using four frameworks: the Kärger model (via kurtosis time-dependence), correlation tensor imaging, Restriction-Exchange, and Multi-Gaussian Exchange with transient kurtosis (tMGE). Dendritic spines were found to impart similar time-dependence signatures on the diffusion-weighted signal as permeative exchange (signal decrease with diffusion time). The effect was modulated by both spine morphology and density. Both the exchange rate and microscopic kurtosis increased with spine density. The tMGE method demonstrated the ability to disentangle geometric from permeative exchange. Non-permeative exchange in dendritic spines has a non-negligible impact on exchange estimates obtained with diffusion MRI and should be considered in future studies. Diffusion MRI exchange estimates may provide a non-invasive proxy for dendritic spine density, with potential applications in studies of neurological disorders.2025-04-30T11:34:44ZArthur ChakwiziraKadir ŞimşekFilip SzczepankiewiczMarco PalomboMarkus Nilssonhttp://arxiv.org/abs/2504.21469v1Turning a Disposable Bronchoscope into a Dynamic Speckle Imaging Tool: Yes, It Works2025-04-30T09:47:43ZDynamic speckle imaging, typically used in laser-illuminated surface diagnostics, has proven valuable for assessing biological activity. In this work, we demonstrate its feasibility in an endoscopic context using a disposable bronchoscope. Despite technical limitations and aliasing artifacts, our preliminary results show discernible vascular structures, indicating potential for minimally invasive diagnostic applications. It is important to note that the imaging systems used in this study are designed primarily for clinical robustness and classical imaging, including single-use sterility, ease of handling, and real-time visualization, and not for scientific fidelity of visual data or computational post-processing. As such, they are not inherently suited to dynamic speckle analysis, which requires precise control over temporal acquisition parameters, linear response characteristics of the imaging sensor, and stable illumination conditions, particularly from the coherent laser source. Nevertheless, our results demonstrate that, even within these constraints, dynamic speckle imaging is indeed achievable. This opens the door to further adaptation and optimization of such clinical imaging tools for functional biomedical investigations.2025-04-30T09:47:43ZAurélien plyerElise ColinEnrique Garcia-Caurelhttp://arxiv.org/abs/2504.21193v1Slug-Mapper: Magnetic Scanner for Ultra Low-Field MRI Scanners2025-04-29T21:54:34ZUltra-Low Field (ULF) MRI scanners offer a portable and cost-effective alternative to conventional MRI systems, but require careful calibration to compensate for reduced magnetic field strength and signal quality. In this paper, we present Slug-Mapper, a low-cost, open-source magnetic field scanner designed to map the static field $B_0$ voxel-by-voxel within the bore of a ULF MRI system. Built using a repurposed 3D printer, a Raspberry Pi, and off-the-shelf components, Slug-Mapper enables high-resolution magnetic field characterization for both passive and active shimming. We provide a detailed overview of MRI physics, the engineering challenges of ULF systems, and the architecture and operation of Slug-Mapper. This tool bridges the gap between hardware prototyping and precise system calibration, supporting the development of accessible and portable MRI technology.2025-04-29T21:54:34ZJonathan W. Morrishttp://arxiv.org/abs/2407.02227v2Interplay between MRI-based axon diameter and myelination estimates in macaque and human brain2025-04-29T20:31:27ZAxon diameter and myelin thickness affect the conduction velocity of action potentials in the nervous system. Imaging them non-invasively with MRI-based methods is thus valuable for studying brain microstructure and function. Electron microscopy studies suggest that axon diameter and myelin thickness are closely related to each other. However, the relationship between MRI-based estimates of these microstructural measures, known to be relative indices, have not been investigated across the brain mainly due to methodological limitations. In recent years, studies using ultra-high gradient strength diffusion MRI (dMRI) have demonstrated improved estimation of axon diameter index across white-matter (WM) tracts in the human brain, making such investigations feasible. In this study, we aim to investigate relationships between tissue microstructure properties across white-matter tracts, as estimated with MRI-based methods. We collected dMRI with ultra-high gradient strength and multi-echo spin-echo MRI on ex vivo macaque and human brain samples on a preclinical scanner. From these data, we found that the correlations between axon diameter index and other microstructural imaging parameters were weak but consistent across WM tracts in samples estimated with sufficient signal to noise ratio. In well-myelinated regions, tissue voxels with larger axon diameter indices were associated with lower packing density, lower MWF and a tendency of higher g-ratio. We also found that intra-axonal signal fractions and MWF were not consistently correlated when assessed in different samples. Overall, the findings suggest that MRI-based axon geometry and myelination measures can provide complementary information about fiber morphology, and the relationships between these measures agree with prior electron microscopy studies in smaller field of views.2024-07-02T12:52:13Z30 pages, 7 figures and 1 table; accepted by imaging neuroscienceTing GongChiara MaffeiEvan DannHong-Hsi LeeHansol LeeJean C. AugustinackSusie Y. HuangSuzanne N. HaberAnastasia Yendikihttp://arxiv.org/abs/2407.06379v2Microstructure.jl: a Julia Package for Probabilistic Microstructure Model Fitting with Diffusion MRI2025-04-29T20:08:32ZMicrostructure.jl is a Julia package designed for probabilistic estimation of tissue microstructural parameters from diffusion or combined diffusion-relaxometry MRI data. It provides a flexible and extensible framework for defining compartment models and includes robust and unified estimators for parameter fitting and uncertainty quantification. The package incorporates several established models from the literature, such as the spherical mean technique and soma and neurite density imaging (SANDI), along with their extensions for analyzing combined diffusion and T2 mapping data acquired at multiple echo times. For parameter estimation, it features methods like Markov Chain Monte Carlo (MCMC) sampling and Monte Carlo dropout with neural networks, which provide probabilistic estimates by approximating the posterior distributions of model parameters. In this study, we introduce the major modules, functionality, and design of this package. We demonstrate its usage in optimizing acquisition protocols and evaluating model fitting performance with synthesized datasets. We also showcase practical applications with publicly available datasets. Microstructure.jl is applicable to in vivo and ex vivo imaging data acquired with typical research, high-performance, or pre-clinical scanners.2024-07-08T20:47:31Z30 pages, 11 figures, 1 tableTing GongAnastasia Yendikihttp://arxiv.org/abs/2504.21123v1Light-Based Fast Timing in Bulk CsPbBr3 Crystals for TOF-PET and Proton Range Verification2025-04-29T19:06:43ZHalide perovskite semiconductors such as CsPbBr3 (CLB) are emerging gamma-ray detectors for applications requiring very high energy resolution and potential for fine detector segmentation. Semiconductor detectors typically offer poor time resolution due to the long drift times. Recently, we proposed to use the Cherenkov light component in partially transparent semiconductors to boost the timing capability of such detectors. Cherenkov light produced upon 511 keV gamma-ray interaction with CLB was investigated by means of optical simulations and experimental measurements. The timing capability of a pair of identical CLB crystals ( 3 x 3 x 5 mm3) coupled to NUV- MT silicon photomultipliers was measured. On average, 9.5 Cherenkov photons are produced in CLB between 555 and 900 nm for 511 keV photoelectric interactions based on our simulation framework. Experimentally, we observe 2-to-3 times more photons detected than in the simulation. The two most likely explanations for these additional detected optical photons are either the partial transparency of CLB in the UV, or a mild scintillation light emitted by CLB at room temperature. A coincidence time resolution (CTR) of 419 ps FWHM was obtained by triggering on more than 2 fired SiPM cells and after time walk correction. The measured CTR confirms the feasibility to use the Cherenkov light-component for fast timing applications on top of the charge readout, toward full 3D localization.2025-04-29T19:06:43ZUnder review in IEEE TRPMSNicolaus KratochwilLeonor ReboloIndra R. PandeyJoshua W. CatesEmilie RoncaliJoshua H. PalmerGerard Arino-Estrada