https://arxiv.org/api/SDv8maMA9mh8708MMPMQSZq7gqM 2026-06-27T07:16:46Z 9008 1350 15 http://arxiv.org/abs/2402.17410v2 Image space formalism of convolutional neural networks for k-space interpolation 2025-05-09T10:02:55Z Purpose: Noise resilience in image reconstructions by scan-specific robust artificial neural networks for k-space interpolation (RAKI) is linked to nonlinear activations in k-space. To gain a deeper understanding of this relationship, an image space formalism of RAKI is introduced for analyzing noise propagation analytically, identifying and characterizing image reconstruction features and to describe the role of nonlinear activations in a human readable manner. Methods: The image space formalism for RAKI inference is employed by expressing nonlinear activations in k-space as element-wise multiplications with activation masks, which transform into convolutions in image space. Jacobians of the de-aliased, coil-combined image relative to the aliased coil images can be expressed algebraically, and thus, the noise amplification is quantified analytically (g-factor maps). We analyze the role of nonlinearity for noise resilience by controlling the degree of nonlinearity in the reconstruction model via the negative slope parameter in leaky ReLU. Results: The analytical g-factor maps correspond with those obtained from Monte Carlo simulations and from an auto differentiation approach for in vivo brain images. Apparent blurring and contrast loss artifacts are identified as implications of enhanced noise resilience. These residual artifacts can be traded against noise resilience by adjusting the degree of nonlinearity in the model (Tikhonov-like regularization) in case of limited training data. The inspection of image space activations reveals an autocorrelation pattern leading to a potential center artifact. Conclusion: The image space formalism of RAKI provides the means for analytical quantitative noisepropagation analysis and human-readable visualization of the effects of the nonlinear activation functions in k-space. 2024-02-27T11:01:58Z Peter Dawood Felix Breuer Istvan Homolya Maximilian Gram Peter M. Jakob Moritz Zaiss Martin Blaimer http://arxiv.org/abs/2304.02470v3 Mechanisms and safety of air plasma inactivated SARS-CoV-2 2025-05-09T08:27:28Z Cold atmospheric plasma (CAP) displays antimicrobial, antitumor, and antiviral properties, while the underlying mechanism is seldom clearly elucidated. In this work, we employed CAP with air-feeding gas to directly inactivate SARS-CoV-2. The results indicate that the typical SARS-CoV-2 morphological spikes disappeared after plasma treatment and the proteosomes of SRAS-CoV-2 were modified. In addition, we also evaluated the safety of the air plasma device in simulating daily life environments through rat experiments. We evaluated rats' daily physiological behavior, body weight, food consumption, organ histopathology, blood biochemical indicators, and so on. These results demonstrate air plasma device is a safe and effective mean prevents virus transmissions and infections. 2023-03-31T01:58:59Z Need more data to support conclusion Guiqiang Wang Dehua Kong Wei Tang Jie Fang Zhitong Chen http://arxiv.org/abs/2505.05812v1 Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising 2025-05-09T06:15:28Z Breast cancer is the most frequently diagnosed human cancer in the United States at present. Early detection is crucial for its successful treatment. X-ray mammography and digital breast tomosynthesis are currently the main methods for breast cancer screening. However, both have known limitations in terms of their sensitivity and specificity to breast cancers, while also frequently causing patient discomfort due to the requirement for breast compression. Breast computed tomography is a promising alternative, however, to obtain high-quality images, the X-ray dose needs to be sufficiently high. As the breast is highly radiosensitive, dose reduction is particularly important. Phase-contrast computed tomography (PCT) has been shown to produce higher-quality images at lower doses and has no need for breast compression. It is demonstrated in the present study that, when imaging full fresh mastectomy samples with PCT, deep learning-based image denoising can further reduce the radiation dose by a factor of 16 or more, without any loss of image quality. The image quality has been assessed both in terms of objective metrics, such as spatial resolution and contrast-to-noise ratio, as well as in an observer study by experienced medical imaging specialists and radiologists. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialized synchrotron facilities. 2025-05-09T06:15:28Z 16 pages, 3 figures, 1 table Ashkan Pakzad Robert Turnbull Simon J. Mutch Thomas A. Leatham Darren Lockie Jane Fox Beena Kumar Daniel Häsermann Christopher J. Hall Anton Maksimenko Benedicta D. Arhatari Yakov I. Nesterets Amir Entezam Seyedamir T. Taba Patrick C. Brennan Timur E. Gureyev Harry M. Quiney http://arxiv.org/abs/2505.05643v1 UltraGauss: Ultrafast Gaussian Reconstruction of 3D Ultrasound Volumes 2025-05-08T20:53:47Z Ultrasound imaging is widely used due to its safety, affordability, and real-time capabilities, but its 2D interpretation is highly operator-dependent, leading to variability and increased cognitive demand. 2D-to-3D reconstruction mitigates these challenges by providing standardized volumetric views, yet existing methods are often computationally expensive, memory-intensive, or incompatible with ultrasound physics. We introduce UltraGauss: the first ultrasound-specific Gaussian Splatting framework, extending view synthesis techniques to ultrasound wave propagation. Unlike conventional perspective-based splatting, UltraGauss models probe-plane intersections in 3D, aligning with acoustic image formation. We derive an efficient rasterization boundary formulation for GPU parallelization and introduce a numerically stable covariance parametrization, improving computational efficiency and reconstruction accuracy. On real clinical ultrasound data, UltraGauss achieves state-of-the-art reconstructions in 5 minutes, and reaching 0.99 SSIM within 20 minutes on a single GPU. A survey of expert clinicians confirms UltraGauss' reconstructions are the most realistic among competing methods. Our CUDA implementation will be released upon publication. 2025-05-08T20:53:47Z Mark C. Eid Ana I. L. Namburete João F. Henriques http://arxiv.org/abs/2504.16805v4 Dosimetric Evaluation of CT-to-RED Calibration Curves on Dosimetric Accuracy in Brain Radiotherapy 2025-05-08T18:12:20Z Accurate radiotherapy dose calculation depends on converting CT Hounsfield Units (HU) to relative electron density (RED) using calibration curves. This study compared three different CT-to-RED calibration curves-two derived from physical phantoms (CIRS 062M and Catphan 604) and one default curve from the Monaco treatment planning system (TPS) by recalculating ten brain tumor VMAT plans. The analysis showed that using the default TPS curve led to dose overestimation (by 3 5 for target volumes and 2 4 for some critical organs) compared to the CIRS phantom-derived curve, which was the most accurate. The Catphan curve had intermediate results. The findings highlight that the choice of calibration curve significantly affects dose accuracy in brain radiotherapy, and site-specific, phantom-based calibration should be prioritized to improve treatment precision and safety. 2025-04-23T15:24:57Z Hossam Donya Duong Thanh Tai Islam G. Ali http://arxiv.org/abs/2505.04172v2 A Dataset and Toolkit for Multiparameter Cardiovascular Physiology Sensing on Rings 2025-05-08T14:40:30Z Smart rings offer a convenient way to continuously and unobtrusively monitor cardiovascular physiological signals. However, a gap remains between the ring hardware and reliable methods for estimating cardiovascular parameters, partly due to the lack of publicly available datasets and standardized analysis tools. In this work, we present $τ$-Ring, the first open-source ring-based dataset designed for cardiovascular physiological sensing. The dataset comprises photoplethysmography signals (infrared and red channels) and 3-axis accelerometer data collected from two rings (reflective and transmissive optical paths), with 28.21 hours of raw data from 34 subjects across seven activities. $τ$-Ring encompasses both stationary and motion scenarios, as well as stimulus-evoked abnormal physiological states, annotated with four ground-truth labels: heart rate, respiratory rate, oxygen saturation, and blood pressure. Using our proposed RingTool toolkit, we evaluated three widely-used physics-based methods and four cutting-edge deep learning approaches. Our results show superior performance compared to commercial rings, achieving best MAE values of 5.18 BPM for heart rate, 2.98 BPM for respiratory rate, 3.22\% for oxygen saturation, and 13.33/7.56 mmHg for systolic/diastolic blood pressure estimation. The open-sourced dataset and toolkit aim to foster further research and community-driven advances in ring-based cardiovascular health sensing. 2025-05-07T06:56:00Z Jiankai Tang Kegang Wang Yingke Ding Jiatong Ji Zeyu Wang Xiyuxing Zhang Ping Chen Yuanchun Shi Yuntao Wang http://arxiv.org/abs/2505.03463v1 Nonperiodic dynamic CT reconstruction using backward-warping INR with regularization of diffeomorphism (BIRD) 2025-05-06T12:01:40Z Dynamic computed tomography (CT) reconstruction faces significant challenges in addressing motion artifacts, particularly for nonperiodic rapid movements such as cardiac imaging with fast heart rates. Traditional methods struggle with the extreme limited-angle problems inherent in nonperiodic cases. Deep learning methods have improved performance but face generalization challenges. Recent implicit neural representation (INR) techniques show promise through self-supervised deep learning, but have critical limitations: computational inefficiency due to forward-warping modeling, difficulty balancing DVF complexity with anatomical plausibility, and challenges in preserving fine details without additional patient-specific pre-scans. This paper presents a novel INR-based framework, BIRD, for nonperiodic dynamic CT reconstruction. It addresses these challenges through four key contributions: (1) backward-warping deformation that enables direct computation of each dynamic voxel with significantly reduced computational cost, (2) diffeomorphism-based DVF regularization that ensures anatomically plausible deformations while maintaining representational capacity, (3) motion-compensated analytical reconstruction that enhances fine details without requiring additional pre-scans, and (4) dimensional-reduction design for efficient 4D coordinate encoding. Through various simulations and practical studies, including digital and physical phantoms and retrospective patient data, we demonstrate the effectiveness of our approach for nonperiodic dynamic CT reconstruction with enhanced details and reduced motion artifacts. The proposed framework enables more accurate dynamic CT reconstruction with potential clinical applications, such as one-beat cardiac reconstruction, cinematic image sequences for functional imaging, and motion artifact reduction in conventional CT scans. 2025-05-06T12:01:40Z Muge Du Zhuozhao Zheng Wenying Wang Guotao Quan Wuliang Shi Le Shen Li Zhang Liang Li Yinong Liu Yuxiang Xing http://arxiv.org/abs/2505.03037v1 Dual Prompting for Diverse Count-level PET Denoising 2025-05-05T21:27:23Z The to-be-denoised positron emission tomography (PET) volumes are inherent with diverse count levels, which imposes challenges for a unified model to tackle varied cases. In this work, we resort to the recently flourished prompt learning to achieve generalizable PET denoising with different count levels. Specifically, we propose dual prompts to guide the PET denoising in a divide-and-conquer manner, i.e., an explicitly count-level prompt to provide the specific prior information and an implicitly general denoising prompt to encode the essential PET denoising knowledge. Then, a novel prompt fusion module is developed to unify the heterogeneous prompts, followed by a prompt-feature interaction module to inject prompts into the features. The prompts are able to dynamically guide the noise-conditioned denoising process. Therefore, we are able to efficiently train a unified denoising model for various count levels, and deploy it to different cases with personalized prompts. We evaluated on 1940 low-count PET 3D volumes with uniformly randomly selected 13-22\% fractions of events from 97 $^{18}$F-MK6240 tau PET studies. It shows our dual prompting can largely improve the performance with informed count-level and outperform the count-conditional model. 2025-05-05T21:27:23Z Published in IEEE International Symposium on Biomedical Imaging (ISBI) 2025 Xiaofeng Liu Yongsong Huang Thibault Marin Samira Vafay Eslahi Tiss Amal Yanis Chemli Keith Johnson Georges El Fakhri Jinsong Ouyang http://arxiv.org/abs/2503.12850v2 In vivo validation of Wireless Power Transfer System for Magnetically Controlled Robotic Capsule Endoscopy 2025-05-05T13:48:35Z This paper presents the in vivo validation of an inductive wireless power transfer (WPT) system integrated for the first time into a magnetically controlled robotic capsule endoscopy platform. The proposed system enables continuous power delivery to the capsule without the need for onboard batteries, thus extending operational time and reducing size constraints. The WPT system operates through a resonant inductive coupling mechanism, based on a transmitting coil mounted on the end effector of a robotic arm that also houses an external permanent magnet and a localization coil for precise capsule manipulation. To ensure robust and stable power transmission in the presence of coil misalignment and rotation, a 3D receiving coil is integrated within the capsule. Additionally, a closed-loop adaptive control system, based on load-shift keying (LSK) modulation, dynamically adjusts the transmitted power to optimize efficiency while maintaining compliance with specific absorption rate (SAR) safety limits. The system has been extensively characterized in laboratory settings and validated through in vivo experiments using a porcine model, demonstrating reliable power transfer and effective robotic navigation in realistic gastrointestinal conditions: the average received power was 110 mW at a distance of 9 cm between the coils, with variable capsule rotation angles. The results confirm the feasibility of the proposed WPT approach for autonomous, battery-free robotic capsule endoscopy, paving the way for enhanced diagnostic in gastrointestinal medicine. 2025-03-17T06:03:49Z 9 pages, 9 figures, regular paper IEEE Sensors Journal 2025, Volume: 25, Issue: 24, Pages: 44729 - 44739 Alessandro Catania Michele Bertozzi Nikita J. Greenidge Benjamin Calme Gabriele Bandini Christian Sbrana Roberto Cecchi Alice Buffi Massimo Macucci Sebastiano Strangio Pietro Valdastri Giuseppe Iannaccone 10.1109/JSEN.2025.11235502 http://arxiv.org/abs/2505.02555v1 Bimodal Cochlear Implants: Measurement of the Localization Performance as a Function of Device Latency Difference 2025-05-05T10:54:08Z Bimodal cochlear implant users show poor localization performance. One reason for this is a difference in the processing latency between the hearing aid and the cochlear implant side. It has been shown that reducing this latency difference acutely improves the localization performance of bimodal cochlear implant users. However, due to the frequency dependency of both the device latencies and the acoustic hearing ear, current frequency-independent latency adjustments cannot fully compensate for the differences, leaving open which latency adjustment is best. We therefore measured the localization performance of eleven bimodal cochlear implant users for multiple cochlear implant latencies. We confirm previous studies that adjusting the interaural latency improves localization in all eleven bimodal cochlear implant users. However, the latency that leads to the best localization performance for most subjects was not at the latency calculated to compensate for the interaural difference at intermediate frequencies (1 kHz). Nine of eleven subjects localized best with a cochlear implant latency that was slightly shorter than the calculated latency compensation. 2025-05-05T10:54:08Z 27 pages, 5 figures, submitted to Trends in Hearing Rebecca C. Felsheim Sabine Hochmuth Alina Kleinow Andreas Radeloff Mathias Dietz http://arxiv.org/abs/2505.01970v1 Determination of the absorbed dose in the brain with DICOM images using GATE/GEANT4 and MATLAB 2025-05-04T02:39:36Z In this study, the absorbed dose calculation for the cerebral region is refined using the Geant4 software, along with the ROOT and GATE programs. This approach provides a detailed statistical analysis of positron trajectories within a water medium, using a voxel-sized source based on PET imaging. By simulating positron displacement within a 4x4x4 mm3 voxel containing radioactive material mixed with water, and bordered by voxels of identical density, the exact absorbed dose in the brain can be precisely determined. PET images, processed in MATLAB, will complement this dosimetric analysis. Results are compared to established guidelines, such as MIRD Pamphlet 17 and ICRP 106, to validate the accuracy and consistency of the absorbed dose calculations. The primary aim of this research is to optimize the absorbed dose in the cerebral region using digital images from the Philips PET-CT Gemini GXL6 scanner at the Radiotherapy and Nuclear Medicine Service, University Hospital of Caracas. The absorbed dose is calculated with the GATE simulator, a Monte Carlo-based tool supported by the Geant4 and ROOT frameworks. The focus is on evaluating the positron displacement from the central voxel to neighboring voxels. Post-simulation, the program algorithms provide detailed data on absorbed doses for both gamma and beta radiation emitted by 18F. This simulation data is then integrated into PET DICOM images within MATLAB. Geometric calculations are applied to further enhance absorbed dose information by leveraging the voxel characteristics of the images, thus optimizing the absorbed dose depiction. Results will be benchmarked against standards like ICRP 109, MIRD Pamphlet 2, and ICRP 53 for validation and optimization. 2025-05-04T02:39:36Z 11 pages, 8 figures Walter Sabalza-Castillejo Miguel Martin-Landrove http://arxiv.org/abs/2505.01940v1 3D neuron growth and neurodevelopmental disorder modeling based on truncated hierarchical B-splines with multi-level local refinements 2025-05-03T22:24:41Z 3D neuron growth and neurodevelopmental disorders (NDDs) deterioration exhibit complex morphological transformations as neurites differentiate into axons and dendrites, forming intricate networks driven by tubulin concentrations and neurotrophin signals. Conventional 2D models fall short of capturing such morphological complexity, prompting the need and development of advanced 3D computational approaches. In this paper, we present a complex 3D neuron growth model based on isogeometric analysis (IGA) and the phase field method, utilizing locally refined truncated hierarchical B-splines (THB-splines). IGA offers isoparametric representation and higher-order continuity, which are essential for simulating the smooth, evolving interfaces of phase field neurites. In contrast, the phase field method can automatically handle diffuse interfaces and complex topological changes without explicit boundary tracking. This IGA-based phase field method enables accurate and efficient simulation of neurite extensions, branching, and retraction in a fully 3D setting. The THB-spline implementation supports multi-level local refinement, focusing computational resources on regions of active growth, while dynamic domain expansion adapts the simulation domain to extend with growing neurites. KD-tree-based interpolation ensures that phase field variables are accurately transferred onto newly refined meshes. NDDs associated neurite deterioration is simulated by modulating the driving force term within the phase field model to induce interface retraction. This comprehensive 3D framework enhances the accuracy of neurite morphology simulations, advancing the study of complex neuron development, network formation and NDDs. 2025-05-03T22:24:41Z 19 pages, 8 figures Kuanren Qian Yongjie Jessica Zhang http://arxiv.org/abs/2505.01909v1 Impact of metal nanoparticles on cell survival predicted by the local effect model for cells in suspension and tissue. Part 1: Theoretical framework 2025-05-03T19:37:21Z This work investigates the change in cell survival predicted by the local effect model (LEM) for an irradiated cell containing metal nanoparticles (MNPs) depending on the distribution of neighboring cells and the uptake of MNPs into the cells. In this first part of the paper, the theoretical framework is described, which is based on analytical weighting functions for the energy deposition around a single metal nanoparticle and radially symmetric distributions of MNPs. The weighting functions allow calculation of the radial profile of the absorbed dose in the cell nucleus as well as the mean dose and the mean square of the dose in the nucleus. The latter two quantities determine cell survival according to the LEM. The weighting functions are applied to isolated cells in a localized MNP distribution, cells in solution, and densely packed cells in tissue. It is shown that only for the idealistic case of complete uptake of MNPs it is sufficient to consider an isolated cell, as this otherwise leads to a significant underestimation in more realistic situations. In the case of cells in tissue, the MNP concentration within the range of secondary particles around the cell must be taken into account. Different packing densities of the cells may lead to values differing by up to 30% for the mean dose in the cell nucleus, depending on the conceived scenario for the uptake of MNPs. The weighting function offers a versatile method for assessing cell survival under irradiation in the presence of MNPs by the LEM, which is more general than previously reported approaches. 2025-05-03T19:37:21Z 43 pages, 19 Figures, 4 Tables plus Supplement (27 pages) Biomed. Phys. Eng. Express 11 (2025) 065002 Hans Rabus Leo Thomas 10.1088/2057-1976/ae07e7 http://arxiv.org/abs/2505.01833v1 Characterization of micro-SPECT system based on Timepix detector 2025-05-03T14:37:32Z In this work, the characteristics of a prototype SPECT system based on the Timepix readout chip, with a MURA type encoding mask, were evaluated. The set-up has a small field of view and can be used in preclinical studies of drugs in small laboratory animals. Despite many existing test protocols developed and described in pertinent documents of national standard bodies and IAEA recommendation, they are not suitable for microtomographic systems based on semiconductor pixel detectors due to different detector technology, high spatial resolution and small area of interest. To measure their characteristics, special phantoms were developed, with a small "hot~region". Such micro-SPECT parameters as spatial resolution, contrast, linearity and system efficiency were studied using Tc-99m source. The detector calibration and data preprocessing are described. 2025-05-03T14:37:32Z V. Rozhkov I. Hernandez A. Leyva A. Zhemchugov http://arxiv.org/abs/2505.01622v1 Wildfire Smoke -- A Rigorous Challenge for HVAC Air Filters 2025-05-02T23:02:13Z Wildfires pose a significant air quality challenge as the smoke they produce can travel long distances and infiltrate indoor spaces. HVAC filters serve as a primary defense against this threat. In our study, we tested over 17 different types of commercially available filter media, including charged and uncharged synthetic, as well as fiberglass media, from leading global manufacturers, to assess their efficiency in removing smoke, using pine needle smoke as a proxy for wildfire smoke. Our findings revealed that charged polymer media, across all tested MERV grades, showed a rapid decline in smoke removal efficiency within minutes while causing no increase in airflow resistance. In contrast, mechanical media demonstrated more stable performance but experienced an increase in airflow resistance. Using scanning electron microscopy (SEM), we examined smoke deposition on fiber media, revealing unique interactions that contribute to the decline in filtration performance. These results suggest the need to reconsider current standards - whose testing is centered around inorganic particle removal - and the applicability of their ratings to smoke filtration. Our study also highlights the critical need to develop standard testing methods and evaluation criteria specific to smoke particles in HVAC filters to better protect human occupants during wildfire events. 2025-05-02T23:02:13Z Tanya Shirman Hediyeh Zamani Sissi Liu