https://arxiv.org/api/G02vMz7u5NvZANGFck6oLzRzowc2026-04-07T11:29:16Z879713515http://arxiv.org/abs/2602.20460v1Radiation damage to normal mammalian tissue in vivo with laser-driven protons at ultra-high instantaneous dose rate2026-02-24T01:39:45ZThe differential sparing of normal tissues relative to tumor control observed at ultra-high dose rates, referred to as the FLASH effect, has recently gained considerable attention. The therapeutic advantages of FLASH radiotherapy are expected to be further amplified through the use of protons and ions, which enable precise dose deposition at tumor depth while minimizing irradiation of healthy tissues proximal and distal to the target. Nevertheless, the mechanism underlying this sparing effect remains poorly understood. Laser-driven proton accelerators are capable of delivering uniquely high instantaneous dose rates in ultrashort bunches. Here, we report the first in vivo investigation of normal tissue response to laser-driven proton irradiation. Our findings reveal a reduction in tissue swelling following laser-driven proton treatment compared with X-ray irradiations at conventional dose rates. RNA sequencing identified differential gene expression associated with immune and epidermal programs following laser-driven proton irradiations at two different dose levels.2026-02-24T01:39:45ZLieselotte Obst-HueblJamie L. InmanJared De ChantKei NakamuraSahel HakimiMorgan ColeHang ChangCameron G. R. GeddesAnthony J. GonsalvesJian-Hua MaoCarl B. SchroederBlake A. SimmonsJeroen van TilborgEric EsareyAntoine M. Snijdershttp://arxiv.org/abs/2602.19829v1Physics-Guided Dual-Domain Network with Attention-Based Fusion for Portable MRI Reconstruction2026-02-23T13:28:05ZPortable low-field magnetic resonance imaging (MRI) systems have gained renewed interest owing to their cost effectiveness and point-of-care imaging capabilities. Yet, portable MRI systems suffer from relatively low signal-to-noise ratio and limited hardware capabilities. While previous works have proposed the use of deep learning based reconstruction methods to improve low-field image quality, these operated only in the image-domain. Unlike other imaging modalities, MRI directly acquires data in the Fourier-domain (k-space), and exploiting both k-space and image-domain information can improve reconstruction quality. Here, we introduce DUN-DD, a novel physics-guided 3D network for portable MRI reconstruction, with parallel dual-domain branches whose outputs are combined together via an attention-based fusion network. To demonstrate the performance of the proposed method, we present \textit{in vivo} reconstructions obtained from both emulated datasets as well as images acquired with a 47mT Halbach-based portable MRI system. Our results show that DUN-DD outperforms state-of-the-art classical, data-driven, and physics-guided methods on both emulated and real portable MRI acquisitions.2026-02-23T13:28:05ZAccepted to 2026 IEEE International Symposium on Biomedical Imaging (ISBI). Copyright 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other usesEfe IlıcakBaris ImreChloé NajacRuben van den BroekBeatrice LenaAndrew WebbMarius Staringhttp://arxiv.org/abs/2602.19712v1SHARP: A compact focusing system for medical applications using a diverging plasma lens2026-02-23T11:02:13ZCancer therapy for deep-seated tumors requires precise irradiation of a small target deep within the patient while minimizing radiation exposure to surrounding tissues. This can be accomplished with a round beam sharply converging towards a single spot, requiring a large beam size in both planes at the exit of the focusing system. Achieving this over a short distance using only quadrupole lenses is challenging; but by using a linear active plasma lens (APL) in defocusing mode, the beam can be quickly and non-destructively enlarged before focusing using quadrupoles. The position of the irradiation spot can also be scanned in three dimensions by changing magnet settings. The SHARP project will develop and test this concept. Such a system can be used with very high energy electrons (hundreds of MeV), creating a Bragg-peak-like spot using novel accelerator technology. This could lead to more compact radiotherapy facilities, not requiring a bulky infrastructure typically associated with proton radiotherapy machines. If successful, SHARP will enable precision conformal radiotherapy, spatial fractionation, and potentially be useful for FLASH radiotherapy.2026-02-23T11:02:13Z18 pages, 9 figures. Submitted to the proceedings of the European Advanced Accelerator Conference (EAAC) 2025Kyrre Ness SjobakElisabeth Rød-LindbergAbélia EllingsenPierre DrobniakVilde Flognfeldt RiekerFardous ReazCarl Andreas LindstrømErik Adlihttp://arxiv.org/abs/2602.19264v1A novel method for analysis of transient morphological changes in quasiperiodic physiological signals and their neurogenic correlates2026-02-22T16:26:53ZFrequently, transient changes in physiological signals, such as ECG morphology, precede or follow a rate change. Current methods for visualizing morphology allow only the tracking of preselected changes, severely limiting analytical capabilities. We introduce a novel method for visualizing quasiperiodic signals, enabling the transformation of time series containing repetitive patterns into intuitive visual representations. By using segmentation algorithms and color encoding, we generate two-dimensional "carpet plots" that facilitate simultaneous assessment of heart rhythm and signal features, including the morphology of QRS complexes and T waves, as well as transient changes in intervals and amplitudes. Additionally, the method supports the assessment of concomitant changes in morphology and rate.
Typically, existing visualization methods, such as the standard 12-lead ECG projection, focus either on rhythm variability or on morphological analysis of a few consecutive beats. In contrast, our method integrates both aspects into a single, coherent graphical representation, greatly enhancing the detection of subtle disturbances and a fascinating dynamic interplay between the rhythm and the morphology of the signal.
We illustrate the effectiveness of this approach using Holter recordings from healthy individuals and patients with arrhythmias, as well as stress test sessions. The results highlight the potential of our visualization technique to support diagnosis and long-term ECG signal analysis. The method may be applied to a broad class of repeatable quasiperiodic patterns - we demonstrate a few examples.2026-02-22T16:26:53Z23 pages, 6 figuresTomasz GradowskiDamian WalągTomir DomańskiTeodor Buchnerhttp://arxiv.org/abs/2603.05523v1Predicting the onset of period-doubling bifurcations via dominant eigenvalue extracted from autocorrelation2026-02-22T13:19:13ZPredicting the occurrence of transitions in the qualitative dynamics of many natural systems is crucial, yet it remains a challenging task. Generic early warning signals like variance and lag-1 autocorrelation identify critical slowing down near tipping points but lack practical thresholds for predicting imminent transitions. More recent studies found that the dynamical eigenvalue is rooted in the framework of empirical dynamical modeling and then estimates the dominant eigenvalue of a system from time series, providing a threshold ($|$DEV$|$ = 1) to predict bifurcations and classify their types. However, its application requires careful calibration of the hyperparameters and focuses on reconstructing system dynamics directly from data. Here, we employ Ornstein-Uhlenbeck process to derive analytic approximations for the lag-$τ$ autocorrelation function prior to period-doubling bifurcation thereby estimating the dominant eigenvalue of dynamical systems, named dominant eigenvalue extracted from autocorrelation (DE-AC), and revealing its dynamic behaviour when approaching a period-doubling bifurcation. Theoretically, dominant eigenvalue tends to $-1$ when the system approaches a period-doubling bifurcation. In particular, we evaluated DE-AC on simulation data from cardiac alternans model and on experimental data from chick heart aggregates undergoing a period-doubling bifurcation. DE-AC reliably detected the beginning of the cardiac arrhythmia (period-doubling bifurcation) in most cases. Moreover, it demonstrated superior sensitivity and specificity as an early warning signal compared to the three widely used indicators -- variance, lag-1 autocorrelation, and dynamical eigenvalue. Our theoretical and empirical results suggest that DE-AC represents a quantitative measure for predicting the onset of potentially dangerous alternating rhythms in the heart.2026-02-22T13:19:13ZZhiqin MaChunhua ZengTing GaoJinqiao Duan10.1016/j.chaos.2026.118010http://arxiv.org/abs/2601.12645v2Radio-frequency pulse design in local rotating frame in magnetic resonance imaging2026-02-21T14:05:55ZThe problem of spatially selective radio-frequency (RF) pulse design in magnetic resonance imaging (MRI) is typically stated in the form of determining, analytically or numerically, RF waveforms to be applied in synchrony with one or more predetermined gradient waveforms. In most cases, the dynamics of the nuclear spin magnetization under the RF and gradient fields is described in a global rotating frame that cancels the effect of the static (main) magnetic field B0. In this work, we consider an alternative frame of reference, which can be called a local rotating frame where total longitudinal magnetic field (B0 plus gradient) in every voxel is zero. In this frame, the effect of time-dependent gradient field is integrated out, and the remaining magnetization dynamics, governed by much weaker RF fields, becomes both simpler and slower. We show that recasting existing RF design methods in such a frame provides useful insights and techniques that are not obvious in the conventional description. The methods we consider include (i) two-dimensional spatial RF pulse design in the excitation k-space, (ii) Shinnar-Le Roux RF design, (iii) residual phase calculation in slice-selective excitation, and (iv) iterative and numerical solutions for multi-coil RF pulse design. In particular, we show that the new formalism can substantially reduce the Bloch simulation time which can greatly benefit iterative pulse designs in parallel transmit. In all, the proposed framework provides considerable theoretical insights and practical utility for RF pulse design in MRI.2026-01-19T01:35:18Z6 figuresSeung-Kyun Leehttp://arxiv.org/abs/2602.18318v1Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector2026-02-20T16:18:02ZIn the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.2026-02-20T16:18:02ZMaxime PinsonAdélie AndréYannick BoursierMathieu DupontMarie-Laure Gallin MartelAlicia GarnierChristophe HoarauPavel KavriginDaniel ManevalChristian MorelJean-François MurazMarco PulliaSimone SavazziSara Marcatilihttp://arxiv.org/abs/2602.17866v1Simple non-invasive methods for obtaining the intensity and timing of arterial pulse waves2026-02-19T22:02:34ZContraction of the left ventricle of the heart increases aortic root blood pressure (P), diameter (D) and blood velocity (U). When contraction diminishes, all three properties decrease. These perturbations propagate down the systemic arteries as the S wave and D wave, respectively. Peak carotid artery S-wave intensity is diminished and delayed in heart failure with reduced ejection fraction (HFrEF). A clinical trial demonstrated that these changes can be used to detect HFrEF with high sensitivity and specificity. Assessment of wave intensity and timing conventionally requires high-frequency, temporally and spatially coincident measurement of changes in P and U or D and U over the cardiac cycle. The practical difficulty of making such measurements accurately and noninvasively limits clinical utility. Here we test simpler methods by using numerical models of wave propagation and data from the clinical trial. We show that methods based on measuring only one of P, D or U can provide good surrogates for the full P-U and D-U methods. The best results were obtained when using measurement of D to assess wave timing. That gave Receiver Operating Characteristics (ROCs) indistinguishable from those based on the full D-U method, with areas under the ROC of up to 0.905 when timing was anchored to the ECG rather than to other waves. Measuring vessel diameter over the cardiac cycle is technically simple and would be a cost-effective way of screening for HFrEF in primary care. Other metrics, similarly measured, might also allow screening for heart failure with preserved ejection fraction (HFpEF).2026-02-19T22:02:34Z25 pages, 10 figuresEthan M. RowlandPeter D. Weinberghttp://arxiv.org/abs/2602.17553v1Enhanced distribution of molecules in the brain due to oscillations of the interstitial flow2026-02-19T17:08:41ZMRI measurements from a decade-old study of the physical properties of brain tissue observed a dynamic, pulsating fluid flow in the interstitial spaces of the brain attributed to the cardiac cycle. The effects of this cyclic flow pattern on the spatial distribution of molecules in the brain are modeled in this paper. The effects of oscillatory flow on the dispersion or volumetric transmission of a molecule that is advected by this flow is modeled by a mechanism hitherto neglected in the literature. An oscillatory random walk model is used to estimate the spread or effective diffusivity due to the oscillatory advection. Then, respiration effects are also estimated and the additional dispersion of molecules due to this are calculated in our model. Our model indicates that the observed oscillatory flow in the interstitial spaces due to cardiac as well as respiratory pulsatility can induce an effective diffusivity when the spread of the molecule is observed over times long compared with a cycle of the oscillation. This would help explain the high-volume transmission within the interstitium or brain parenchyma found in MRI measurements of a marker infused into the cerebrospinal fluid in human subjects that is well above what would be expected. Interstitial spaces should be viewed as a region of dynamic oscillatory flow driven by cardiac and respiratory cycles. This oscillatory flow could result in a significant dispersion of molecules and explain the higher-than-expected effective diffusion suggested in human studies. It may be possible to augment or slow this flow and concomitant spread by applying external forces.2026-02-19T17:08:41Z31 pages, 7 figuresRaghu RaghavanRichard D. Pennhttp://arxiv.org/abs/2602.17389v1Geometric and topological constraints on oral seal formation during infant breastfeeding2026-02-19T14:13:07ZBreastfeeding efficiency relies on coordinated tongue motion, sustained tissue contact and maintenance of an effective intraoral seal. Current assessments of seal formation mainly use local kinematic descriptors or pressure recordings, which do not capture the global structural continuity of the sealing region. We introduce a systolic geometry based approach in which each sagittal ultrasound frame is modeled as a two dimensional deformable domain bounded by tongue, palate and nipple contours. Global seal continuity is formalized through the shortest closed curve that cannot be contracted to a point because of the overall geometry of the domain. The nipple defines a central region that must be circumferentially enclosed by a contact band to maintain suction. Within this band, closed curves encircling the nipple exactly once can be identified; the shortest of these curves defines a normalized systolic index representing the tightest admissible sealing loop. Simulations of symmetric thinning, localized discontinuities and cyclic perturbations reveal feasibility boundaries separating seal preserving from seal breaking configurations. Notably, admissible encircling curves may transiently disappear even when overall geometric motion remains smooth. By capturing global circumferential continuity that cannot be inferred from local metrics alone, our approach generates testable hypotheses linking the existence and temporal stability of admissible encircling curves to milk transfer efficiency and vacuum stability. Applied to segmented ultrasound data and integrated with pressure measurements, our systolic approach could provide a quantitative framework for objective assessment of seal integrity and longitudinal monitoring of latch stability.2026-02-19T14:13:07Z8 pages, 2 figuresArturo Tozzihttp://arxiv.org/abs/2511.19547v2Placental contractions in uncomplicated pregnancies2026-02-19T14:06:09ZIn 2020 we first described placental contractions, and we have now undertaken a study to characterise them and seek features that might automatically separate them from uterine contractions. We recruited 36 healthy pregnant women to undergo magnetic resonance imaging (MRI) between 29 and 42 weeks of pregnancy in a single-centre, prospective, observational study. Participants had fetal ultrasound to confirm normal growth. Dynamic MRI was acquired for between 15 and 32 minutes using respiratory triggered, multi-slice, single shot, gradient echo, echo planar imaging covering the whole uterus. All participants had a live birth of a healthy baby weighing over the 10th centile for gestational age and none developed any associated conditions of placental dysfunction e.g. pre-eclampsia, or severe maternal or fetal villous malperfusion on placental histopathology. Any visible contractions were recorded for all participants who completed their MRI scan and placental contractions occurred in at least 60% of our healthy pregnant population with a median frequency of approximately 2 per hour, and a median duration of 2.4 minutes. Contractions involving a decrease in placental volume of >10% were classified as either placental or uterine by visual observation. Placental contractions occurred more frequently than uterine contractions (p=0.0061), were associated with a larger increase in the surface area of the uterine wall not covered by the placenta (p=0.0015), placental sphericity (p<0.0001) and longer duration (p=0.0151). All contractions led to an increase in the MRI parameter R2* in the placenta. There was large variation both between participants and between contractions from the same individual, in terms of time course and contractions features, with no apparent change across the gestational age range studied, although the largest fractional volume changes were detected at early gestation.2025-11-24T11:46:34ZLouise DewickAmy L TurnbullKate F WalkerNia W JonesGeorge HutchinsonChristopher BradleyTaqwa FerdousAisha RazzaqueRuizhe LiXin ChenGrazziela FigueredoCraig PlattCesar PeresPenny Gowlandhttp://arxiv.org/abs/2602.04375v2Angle dependent dose transformer algorithm for fast proton therapy dose calculations2026-02-18T15:53:42ZAccurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose engines often require orthogonality between proton rays and the CT grid, forcing computationally expensive beamlet-wise 3D reinterpolation. We propose the Angle-dependent Dose Transformer Algorithm (ADoTA), which eliminates grid rotation by augmenting the model input with a fast analytical beamlet-shape projection that explicitly encodes beam direction. The model was trained on CT data from 108 patients to predict beamlet dose distributions for initial energies of $70$--$270\,\mathrm{MeV}$ over an $80\times110\,\mathrm{mm}^2$ field, and tested on an independent cohort of 50 patients. On the test set, gamma pass rates $(1\%,3\,\mathrm{mm})$ were $99.40\pm0.86\%$ (thorax) and $99.87\pm0.23\%$ (abdomen/pelvis). Single-beamlet inference took $1.72\pm0.8\,\mathrm{ms}$. By avoiding reinterpolation, end-to-end 3D dose computation was reduced by $\approx86\%$ relative to the fastest published reinterpolation-based methods. For full treatment plans, gamma pass rates $Γ(2\%,2\,\mathrm{mm})$ with a 10\% dose cut-off reached $98.4\%$ (lung) and $98.9\%$ (prostate). ADoTA provides an angle-aware deep-learning proton dose engine that preserves MC-level accuracy across heterogeneous anatomies while substantially reducing computational overhead.2026-02-04T09:52:00Z27 pages, 15 Figures, 7 Tables Code can be found: https://github.com/Medical-Physics-Technology/adotaMikołaj StryjaDanny LathouwersZoltán Perkóhttp://arxiv.org/abs/2602.16000v1Imaging-Derived Coronary Fractional Flow Reserve: Advances in Physics-Based, Machine-Learning, and Physics-Informed Methods2026-02-17T20:46:25ZPurpose of Review Imaging derived fractional flow reserve (FFR) is rapidly evolving beyond conventional computational fluid dynamics (CFD) based pipelines toward machine learning (ML), deep learning (DL), and physics informed approaches that enable fast, wire free, and scalable functional assessment of coronary stenosis. This review synthesizes recent advances in CT and angiography based FFR, with particular emphasis on emerging physics informed neural networks and neural operators (PINNs and PINOs) and key considerations for their clinical translation. Recent Findings ML/DL approaches have markedly improved automation and computational speed, enabling prediction of pressure and FFR from anatomical descriptors or angiographic contrast dynamics. However, their real-world performance and generalizability can remain variable and sensitive to domain shift, due to multi-center heterogeneity, interpretability challenges, and differences in acquisition protocols and image quality. Physics informed learning introduces conservation structure and boundary condition consistency into model training, improving generalizability and reducing dependence on dense supervision while maintaining rapid inference. Recent evaluation trends increasingly highlight deployment oriented metrics, including calibration, uncertainty quantification, and quality control gatekeeping, as essential for safe clinical use. Summary The field is converging toward imaging derived FFR methods that are faster, more automated, and more reliable. While ML/DL offers substantial efficiency gains, physics informed frameworks such as PINNs and PINOs may provide a more robust balance between speed and physical consistency. Prospective multi center validation and standardized evaluation will be critical to support broad and safe clinical adoption.2026-02-17T20:46:25Z26 pages 4 tablesTanxin ZhuEmran HossenChen ZhaoMichele EspositoJiguang SunWeihua Zhouhttp://arxiv.org/abs/2212.00126v3Proton Computed Tomography Image Reconstruction Based on the Richardson-Lucy Algorithm2026-02-17T17:08:34ZProton therapy is an emerging method in cancer therapy. One of the main developments is to increase the accuracy of the Bragg-peak position calculation, which requires more precise relative stopping power (RSP) measurements. A promising choice is the application of proton computed tomography (pCT) systems which takes the images under similar conditions, as they use the same irradiation device and hadron beam for imaging and treatment. A key aim is to develop a precise image reconstruction algorithm for pCT systems to reach their maximal performance.
In this work, an iterative image reconstruction algorithm, based on the Richardson-Lucy iteration is proposed for the first time for proton CT image reconstruction. Monte Carlo (MC) simulations of CTP528 and CTP404 phantoms were used to benchmark the proposed method. In the case of an idealized detector setup, using a 1 mm pitch grid, 4.88 lp/cm spatial resolution and 0.66% average RSP uncertainty was achieved. The present method provides a promising proof-of-concept candidate for compromise between accuracy and speed with several further development directions.2022-11-30T21:28:10ZGábor BíróÁkos SudárZsófia JóleszGábor PappGergely Gábor Barnaföldihttp://arxiv.org/abs/2602.15672v1Dosimetric Study of Lung Modulation and Motion Effects in Carbon ion Therapy for Lung Cancer2026-02-17T15:55:04ZCarbon-ion radiotherapy provides high dose conformity for lung cancer, but its benefit is limited by two sources of uncertainties: interplay between scanned beam delivery and tumor motion, and dose modulation from heterogeneous lung tissue. This study quantifies the separate and combined dosimetric impact of these effects using the GSI TRiP4D treatment planning system. Eighteen lung cancer 4DCT datasets from TCIA were analyzed. A modulation power ($P_{\mathrm{mod}}$) was assigned to lung voxels. Three values were sampled from a Gaussian distribution ($200μ\mathrm{m} \pm 67μ\mathrm{m}$), and an extreme value of $750μ\mathrm{m}$ was tested. Interplay doses were computed by combining scanned-beam delivery with patient-specific respiratory motion. Four scenarios were studied: static, static with modulation, interplay, and interplay with modulation. Metrics included $D95\%$, $V95\%$, homogeneity index (HI), lung $V16\mathrm{Gy}$, and heart $V20\mathrm{Gy}$. Interplay reduced target coverage by $5.2 \pm 1.5$ pp ($D95\%$), $12.1 \pm 5.9$ pp ($V95\%$), and $8.3 \pm 2.4$ pp (HI). Extreme $P_{\mathrm{mod}}$ alone caused small degradations. When combined with interplay, it partially compensated the loss. This effect decreased with 4D optimization. Fractionation mitigated interplay, leaving lung modulation as the main residual effect.2026-02-17T15:55:04ZMaria Chiara MartireLennart VolzMarco DuranteChristian Graeff