https://arxiv.org/api/sIiCIyoN/PgfNwyLINuDg4YhpfE2026-06-27T06:22:01Z9008133515http://arxiv.org/abs/2505.09796v1Virtual Dosimetrists: A Radiotherapy Training "Flight Simulator"2025-05-14T20:47:13ZEffective education in radiotherapy plan quality review requires a robust, regularly updated set of examples and the flexibility to demonstrate multiple possible planning approaches and their consequences. However, the current clinic-based paradigm does not support these needs. To address this, we have developed 'Virtual Dosimetrist' models that can both generate training examples of suboptimal treatment plans and then allow trainees to improve the plan quality through simple natural language prompts, as if communicating with a dosimetrist. The dose generation and modification process is accurate, rapid, and requires only modest resources. This work is the first to combine dose distribution prediction with natural language processing; providing a robust pipeline for both generating suboptimal training plans and allowing trainees to practice their critical plan review and improvement skills that addresses the challenges of the current clinic-based paradigm.2025-05-14T20:47:13ZSkylar S. GayTucker NethertonBarbara MarquezRaymond MummeMary GronbergBrent ParkerChelsea PinnixSanjay SheteCarlos CardenasLaurence Courthttp://arxiv.org/abs/2505.09667v1An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose2025-05-14T17:52:27ZNanodosimetry relates Ionization Detail (ID) and ionization parameters (Ip) to biological endpoints relevant for charged-particle radiotherapy. This supports a more physics-based modeling of biological effectiveness than traditional dose-response relationships and RBE models. Faddegon et al. (2023) introduced cluster dose g(Ip) as a physical quantity, bridging ID to the treatment planning level, which can be directly optimized. We developed a framework enabling cluster dose optimization via a pencil-beam (PB) algorithm, and validated against Monte Carlo (MC) simulations. The framework, integrated into the treatment planning toolkit matRad, uses precomputed Ip values obtained from MC track-structure simulations. We applied our tool for plan optimization with protons, helium, and carbon ions in a water phantom and a prostate case. Recalculation with TOPAS showed 3D gamma passing rates >97% (phantom) and >98% (patient) using a 3%/3mm criterion and a threshold of 10% of the maximum dose. Cluster dose F5 optimization produced homogeneous target coverage, with heavier ions requiring lower absorbed doses for the same prescribed cluster dose level. This demonstrates the feasibility of fast, accurate cluster dose optimization using PB algorithms.2025-05-14T17:52:27ZSimona FacchianoDepartment of Medical Physics in Radiation Oncology E040, DKFZ, HeidelbergNational Center for Radiation Research in OncologyFaculty of Physics and Astronomy, Heidelberg UniversityRamon OrtizDepartment of Radiation Oncology, UCSF, San FranciscoRemo CristoforettiDepartment of Medical Physics in Radiation Oncology E040, DKFZ, HeidelbergNational Center for Radiation Research in OncologyFaculty of Physics and Astronomy, Heidelberg UniversityNaoki D-KondoDepartment of Radiation Oncology, UCSF, San FranciscoOliver JaekelDepartment of Medical Physics in Radiation Oncology E040, DKFZ, HeidelbergNational Center for Radiation Research in OncologyDepartment of Radiation Oncology, Heidelberg Ion Beam Therapy CenterBruce FaddegonDepartment of Radiation Oncology, UCSF, San FranciscoNiklas WahlDepartment of Medical Physics in Radiation Oncology E040, DKFZ, HeidelbergNational Center for Radiation Research in Oncologyhttp://arxiv.org/abs/2502.00762v2On Overlap Ratio in Defocused Electron Ptychography2025-05-14T16:10:58ZFour-dimensional Scanning Transmission Electron Microscopy (4D STEM) with data acquired using a defocused electron probe is a promising tool for characterising complex biological specimens and materials through a phase retrieval process known as Electron Ptychography (EP). The efficacy of 4D STEM acquisition and the resulting quality of EP reconstruction depends on the overlap ratio of adjacent illuminated areas. This paper demonstrates how the overlap ratio impacts the data redundancy and the quality of the EP reconstruction. We define two quantities as a function of the overlap ratio that are independent of both the object and the EP algorithm. Subsequently, we evaluate an EP algorithm for varying overlap ratios using simulated 4D STEM datasets. Notably, a 40% or greater overlap ratio yields stable, high-quality reconstructions.2025-02-02T11:53:55ZAmirafshar MoshtaghpourAngus I. Kirklandhttp://arxiv.org/abs/2501.18872v2Stereotactic Arrhythmia Radioablation for Refractory Ventricular Tachycardia: A Narrative Review and Exploratory Pooled Analysis of Clinical Outcomes and Toxicity2025-05-14T14:11:34ZPurpose: Stereotactic arrhythmia radioablation (STAR) is a non-invasive salvage therapy for refractory ventricular tachycardia (VT), especially in patients ineligible for catheter ablation. This narrative review and pooled analysis evaluates the safety, efficacy, and technical characteristics of STAR, integrating preclinical studies, case reports, case series, and clinical trials. Methods and Materials: A comprehensive review identified 86 studies published between 2015 and 2025, including 12 preclinical studies, 49 case reports, 18 case series, and 7 clinical trials. Study-level data were extracted for pooled analysis of 6- and 12-month mortality, VT burden reduction, and grade 3+ acute toxicities. Subgroup analyses were performed by delivery modality, age, left ventricular ejection fraction (LVEF), and cardiomyopathy type. Results: Pooled mortality was 16% (95% CI: 11-20%) at 6 months and 33% (95% CI: 27-38%) at 12 months. VT burden reduction at 6 months averaged 75% (95% CI: 73-77%) but showed substantial heterogeneity (I^2 = 98.8%). Grade 3+ acute toxicities occurred in 7% (95% CI: 4-10%), with heart failure being most common. Subgroup analyses suggested better outcomes in younger patients, those with NICM, and those with higher LVEF. Conclusions: STAR is a promising salvage therapy with favorable acute safety and efficacy. Outcome heterogeneity and inconsistent reporting highlight the need for standardized definitions, dosimetric protocols, and longer-term follow-up. Prospective trials and real-world registries are critical for refining STAR's role in VT management.2025-01-31T03:47:44Z39 pages, 3 figuresKeyur D. ShahChih-Wei ChangSibo TianPretesh PatelRichard QiuJustin RoperJun ZhouZhen TianXiaofeng Yang10.1002/acm2.70622http://arxiv.org/abs/2505.09245v1Evaluating the effectiveness of concrete and metal shields in photoneutron reduction: A Monte Carlo study2025-05-14T09:35:17ZIntroduction: Neutrons are produced when photons interact with parts of the accelerator, materials in the treatment room, or the patient's body. These neutrons have significant biological effects due to their high quality factor, potentially leading to secondary cancers. Material and method: A Monte Carlo simulation was conducted using the MCNPX code to model an Elekta Infinity linear accelerator operating at 18 MV. The accelerator was situated inside a bunker measuring 7.4* 5 m2. To study photoneutron production and the effectiveness of shielding, various concrete mixtures were applied to the walls of the maze and treatment room. Results: Regardless of the modifications, both photon and neutron fluence decreased substantially as the distance from the maze entrance increased. The fluence reduction was more pronounced between the maze entrance and center. The lowest equivalent neutron doses behind the treatment room door were observed when Ord-Lim concrete was used, while the highest doses occurred with Gal-Bar concrete. Conclusion: The configuration of concrete layers within the treatment room and maze walls is a key factor influencing the changes in neutron dose behind the treatment room door. These variations result from differences in concrete composition and the way neutrons are absorbed in different setups.2025-05-14T09:35:17ZMohammad Hossein JahanimehrSeyed Mohammad Mahdi Abtahihttp://arxiv.org/abs/2505.09170v1Modeling Indoor PM$_{2.5}$ Exposure During Retrofits: Plastic Film Barriers and a Quadratic Baseline Approach2025-05-14T06:07:59ZTemporary plastic film barriers are widely used to separate occupied rooms from exterior renovation zones, yet their effect on indoor particulate exposure is poorly quantified. We monitored PM$_{2.5}$ in a Tampa, Florida, apartment for 48 days with a low-cost optical sensor (Temtop LKC-1000S+), spanning pre-barrier, barrier-on, and post-barrier periods. A quadratic baseline was fitted to "background" minutes devoid of identifiable indoor sources, allowing excess concentrations ($Δ$PM) to be partitioned into facade work, cooking, and passive accumulation without outdoor co-monitoring. The barrier prevented large construction spikes indoors but curtailed natural ventilation, doubling the mean baseline from 1.9 to 3.9 $μ$g m$^{-3}$. During this stage, passive build-up accounted for $45\,\%$ of the daily excess dose, with facade work and cooking contributing $31\,\%$ and $24\,\%$, respectively. Once the new window was installed and evening airing resumed, the baseline fell to 0.8 $μ$g m$^{-3}$, the lowest of the campaign. Our findings highlight the trade-off between dust shielding and background elevation and demonstrate that simple polynomial fitting bolsters low-cost IAQ diagnostics in mechanically unventilated dwellings. The framework is readily transferable to other retrofits; future studies should pair indoor sensing with outdoor references and multi-room deployments to refine infiltration estimates.2025-05-14T06:07:59ZCase study (9 pp). Focus on the plastic film barrier and its impact on indoor PM$_{2.5}$. Not peer-reviewed; full version in preparationIEEE Sensors Letters 2025Rostyslav SipakovOlena Voloshkina10.1109/LSENS.2025.3603121http://arxiv.org/abs/2505.08927v1Predictive Digital Twins with Quantified Uncertainty for Patient-Specific Decision Making in Oncology2025-05-13T19:52:50ZQuantifying the uncertainty in predictive models is critical for establishing trust and enabling risk-informed decision making for personalized medicine. In contrast to one-size-fits-all approaches that seek to mitigate risk at the population level, digital twins enable personalized modeling thereby potentially improving individual patient outcomes. Realizing digital twins in biomedicine requires scalable and efficient methods to integrate patient data with mechanistic models of disease progression. This study develops an end-to-end data-to-decisions methodology that combines longitudinal non-invasive imaging data with mechanistic models to estimate and predict spatiotemporal tumor progression accounting for patient-specific anatomy. Through the solution of a statistical inverse problem, imaging data inform the spatially varying parameters of a reaction-diffusion model of tumor progression. An efficient parallel implementation of the forward model coupled with a scalable approximation of the Bayesian posterior distribution enables rigorous, but tractable, quantification of uncertainty due to the sparse, noisy measurements. The methodology is verified on a virtual patient with synthetic data to control for model inadequacy, noise level, and the frequency of data collection. The application to decision-making is illustrated by evaluating the importance of imaging frequency and formulating an optimal experimental design question. The clinical relevance is demonstrated through a model validation study on a cohort of patients with publicly available longitudinal imaging data.2025-05-13T19:52:50ZGraham PashUmberto VillaDavid A. HormuthThomas E. YankeelovKaren Willcoxhttp://arxiv.org/abs/2505.08571v1Analysis of gesture-sound decorrelation in electronic drumming2025-05-13T13:46:07ZDrumming belongs to a family of musical instruments whose practice, whether as an amateur or at a high level, is associated with an increased risk of musculoskeletal disorders (MSD), particularly of the upper limbs and lumbar spine. The vast majority of drummers learn to play on acoustic instruments, the sound intensity of which is proportional to the striking force developed. This correlation is disrupted when playing the electronic version of the instrument, which is often purchased by musicians seeking to reduce the sound produced (e.g. playing in apartments). The aim of this study was therefore to analyze whether drumming on electronic equipment would lead to a change in the kinematics and feel of drummers. To this end, several drummers were recruited to perform repeated rhythms at different pitches on acoustic and electric drums under two sound conditions (sound on and sound off with noise-canceling headphones). The sound produced and the kinematics of the upper limbs were measured by video motion capture during the beats. In addition, self-confrontation interviews were conducted after each condition. The drummers, confronted with video recordings of their actions, were asked to describe, explain and comment step by step on their performance. These interviews were also used to assess their ability to maintain a constant strike force. A questionnaire was used to obtain subjective information on how they felt. The results showed a lower sound power of electronic drums, despite a similar striking speed. This gesture-sound decorrelation could explain the increase in MSD among drummers when switching from an acoustic to an electronic instrument.2025-05-13T13:46:07Zin French language, 17e Congr{è}s Fran{\c c}ais d'Acoustique, Soci{é}t{é} Fran{\c c}aise d'Acoustique, 2025, Paris, FranceMathias BlandeauLAMIHEugénie AvrilLAMIHhttp://arxiv.org/abs/2505.08482v1Reconstructing initial pressure and speed of sound distributions simultaneously in photoacoustic tomography2025-05-13T12:09:46ZImage reconstruction in photoacoustic tomography relies on an accurate knowledge of the speed of sound in the target. However, the speed of sound distribution is not generally known, which may result in artefacts in the reconstructed distribution of initial pressure. Therefore, reconstructing the speed of sound simultaneously with the initial pressure would be valuable for accurate imaging in photoacoustic tomography. Furthermore, the speed of sound distribution could provide additional valuable information about the imaged target. In this work, simultaneous reconstruction of initial pressure and speed of sound in photoacoustic tomography is studied. This inverse problem is known to be highly ill-posed. To overcome this, we study an approach where the ill-posedness is alleviated by utilising multiple photoacoustic data sets that are generated by different initial pressure distributions within the same imaged target. Then, these initial pressure distributions are reconstructed simultaneously with the speed of sound distribution. A methodology for solving this minimisation problem is formulated using a gradient-based iterative approach equipped with bound constraints and a multigrid approach. The methodology was evaluated with numerical simulations. Different approaches for generating multiple initial pressure distributions and their effect on the solution of the image reconstruction problem were studied. The results show that initial pressure and speed of sound can be simultaneously reconstructed from photoacoustic data. Furthermore, utilising multiple initial pressure distributions improves the reconstructions such that the locations of initial pressure and speed of sound inhomogeneities can be better distinguished and image artifacts are reduced.2025-05-13T12:09:46ZMiika SuhonenFelix LuckaAki PulkkinenSimon ArridgeBen CoxTanja Tarvainen10.1016/j.pacs.2025.100748http://arxiv.org/abs/2505.07088v1A Rapid Reconstruction Method of Gamma Radiation Field based on Normalized Proper Orthogonal Decomposition2025-05-11T18:37:28ZWhen a fault occurs in nuclear facilities, accurately reconstructing gamma radiation fields through measurements from the mobile radiation detection (MRD) system becomes crucial to enable access to internal facility areas for essential safety assessments and repairs. Reconstruction of these fields is difficult because of the uncertainty in the positions and intensities of the gamma sources, the complexity of the gamma distribution, and the physics and radiation hardness constraints on the MRD systems. In this work, a novel reconstruction framework of the gamma radiation is proposed. This system entails a NPOD-based reconstruction algorithm with MRD data, and a variation-based adaptive measurements selection mechanism. Our approach has been thoroughly assessed using extensive simulations, and the results clearly prove its success and efficiency in reconstruction radiation fields accurately and quickly. Furthermore, the designed selection algorithm is also promising for extensive application to other optimization tasks of location selection.2025-05-11T18:37:28ZKai TanHojoon SonFan Zhanghttp://arxiv.org/abs/2505.02318v2Information-Theoretic Analysis of Brain MRI: Mutual Information and Pixel Intensity Patterns in Tumor vs. Normal Tissues2025-05-10T06:49:34ZThe application of information theory in medical imaging, particularly in magnetic resonance imaging (MRI), offers powerful quantitative tools for analyzing structural differences in brain tissues. This study utilizes mutual information (MI) and pixel intensity distributions to differentiate between normal and tumor-affected brain MRI images. Mutual information analyses revealed significantly higher MI values in tumor images compared to normal ones, indicating greater internal similarity within tumor images. Pixel intensity analysis further demonstrated distinct distribution patterns between the two groups: tumor images showed pronounced pixel frequency concentrations within a specific intensity range (0.3, 0.4), suggesting predictable structural characteristics. Conversely, normal images exhibited broader, more uniform pixel intensity distributions across most intensity ranges, except for an initial peak observed in both groups. These findings highlight the capability of information-theoretic metrics, such as mutual information and pixel intensity analysis, to effectively distinguish tumor tissue from normal brain structures, providing promising avenues for enhanced diagnostic and analytical methods in neuroimaging.2025-05-05T02:25:08Zchanged in references formatMazaher KabiriShahd Qasem Mahd Tarmanhttp://arxiv.org/abs/2505.06490v1Phase-based stimulated emission depletion (pSTED) magnetic particle imaging2025-05-10T02:07:47ZMagnetic particle imaging (MPI) is an in vivo method to detect magnetic nanoparticles for cell tracking, vascular imaging, and molecular target imaging without ionizing radiation. Current magnetic particle imaging is accomplished by forming an field-free line (FFL) through a gradient selection field. By translating and rotating FFL under excitation and drive fields, the harmonic complex signal of a point source forms a Lorentzian-shape point spread function on the plane perpendicular to FFL. The Lorentzian PSF has a finite size and limited resolution due to the non-sharp Langevin function and weak selection field. This study proposes a donut-shaped focal spot by borrowing the stimulated emission depletion (STED) fluorescence microscopy principle. The influence of the gradient selection field on the relaxation time of magnetic particles determines the nonlinear phase shift of the harmonic complex signals, resulting in the formation of a donut-shaped focal spot. By subtracting the donut-shaped focal spot from the Lorentzian focal spot, the STED focal spot size was reduced by up to 4 times beyond the Langevin magnetization resolution barrier. In human brain FFL-based MPI scanner, the donut-shaped focal spot can be used to reconstruct images with super-resolution and super-sensitivity through the deconvoution of the STED focal spot and filtered backprojection algorithm.2025-05-10T02:07:47Z13 pages, 3 figuresGuang JiaZhongwei BianTianshu LiShi BaiYongchen GouYiwen LiLixuan ZhaoJia LuoMingli PengWeihua LiPeng GaoTanping LiHui HuiJie Tianhttp://arxiv.org/abs/2505.02695v2Estimations of lung structural properties from a single propagation-based dark-field X-ray image2025-05-09T22:28:00ZIn this investigation, we applied a single-projection dark-field imaging technique to gain statistical information on the smallest airway structures within the lung$\unicode{x2014}$the alveoli$\unicode{x2014}$focusing on their size and number as key indicators of lung health. The algorithm employed here retrieves the projected thickness of the sample from a propagation-based phase contrast image using the transport-of-intensity equation. The first Born approximation is then used to isolate the dark-field signal associated with edge scattering, which increases the visibility of microstructure boundaries. PMMA spheres of known sizes were imaged first as an idealised alveolar model. The dark-field signal was then recovered from propagation-based phase-contrast X-ray images of the lungs of small mammals using this method. The retrieved dark-field signal was found to be proportional to both the alveolar size ($R^2 = 0.85$) and the number in projection ($R^2 = 0.69$), and these measurements could be combined to provide an estimate of the total surface area of the alveolar interfaces ($R^2 = 0.78$). This demonstrates the approach's ability to indicate lung health using the dark-field signal retrieved from a single-phase-contrast X-ray image.2025-05-05T14:44:19Z15 pages, 11 figuresDylan W. O'ConnellKaye S. MorganLinda C. P. CrotonJames A. PollockGary RubenKelly J. CrossleyMegan J. WallaceErin. V. McGillickStuart B. Hooper. Marcus J. Kitchenhttp://arxiv.org/abs/2505.06223v1A Proton Treatment Planning Method for Combining FLASH and Spatially Fractionated Radiation Therapy to Enhance Normal Tissue Protection2025-05-09T17:57:30ZBackground: FLASH radiation therapy (FLASH-RT) uses ultra-high dose rates to induce the FLASH effect, enhancing normal tissue sparing. In proton Bragg peak FLASH-RT, this effect is confined to high-dose regions near the target at deep tissue levels. In contrast, Spatially Fractionated Radiation Therapy (SFRT) creates alternating high- and low-dose regions with high peak-to-valley dose ratios (PVDR), sparing tissues at shallow-to-intermediate depths. Purpose: This study investigates a novel proton modality (SFRT-FLASH) that synergizes FLASH-RT and SFRT to enhance normal tissue protection across all depths. Methods: Two SFRT techniques are integrated with FLASH-RT: proton GRID therapy (pGRID) with conventional beam sizes and proton minibeam radiation therapy (pMBRT) with submillimeter beams. These are implemented as pGRID-FLASH (SB-FLASH) and minibeam-FLASH (MB-FLASH), respectively. The pGRID technique uses a scissor-beam (SB) method to achieve uniform target coverage. To meet FLASH dose (5 Gy) and dose-rate (40 Gy/s) thresholds, a single-field uniform-dose-per-fraction strategy is used. Dose and dose-rate constraints are jointly optimized, including a CTV1cm structure (a 1 cm ring around the CTV) for each field. Results: Across four clinical cases, MB-FLASH and SB-FLASH plans were benchmarked against conventional (CONV), FLASH-RT (FLASH), pMBRT (MB), and pGRID (SB) plans. SFRT-FLASH achieved high FLASH effect coverage (~60-80% in CTV1cm) while preserving PVDR (~2.5-7) at shallow-to-intermediate depths. Conclusions: We present a proton treatment planning approach that combines the FLASH effect at depth with high PVDR near the surface, enhancing normal tissue protection and advancing proton therapy.2025-05-09T17:57:30ZWeijie ZhangXue HongYa-Nan ZhuYuting LinGregory GanRonald C ChenHao Gaohttp://arxiv.org/abs/2505.04550v2An imageless magnetic resonance framework for fast and cost-effective decision-making2025-05-09T10:48:29ZMagnetic Resonance Imaging (MRI) is the gold standard in countless diagnostic procedures, yet hardware complexity, long scans, and cost preclude rapid screening and point-of-care use. We introduce Imageless Magnetic Resonance Diagnosis (IMRD), a framework that bypasses k-space sampling and image reconstruction by analyzing raw one-dimensional MR signals. We identify potentially impactful embodiments where IMRD requires only optimized pulse sequences for time-domain contrast, minimal low-field hardware, and pattern recognition algorithms to answer clinical closed queries and quantify lesion burden. As a proof of concept, we simulate multiple sclerosis lesions in silico within brain phantoms and deploy two extremely fast protocols (approximately 3 s), with and without spatial information. A 1D convolutional neural network achieves AUC close to 0.95 for lesion detection and R2 close to 0.99 for volume estimation. We also perform robustness tests under reduced signal-to-noise ratio, partial signal omission, and relaxation-time variability. By reframing MR signals as direct diagnostic metrics, IMRD paves the way for fast, low-cost MR screening and monitoring in resource-limited environments.2025-05-07T16:31:26ZAlba González-CebriánPablo García-CristóbalFernando GalveEfe IlıcakViktor Van Der ValkMarius StaringAndrew WebbJoseba Alonso