https://arxiv.org/api/6TyNJRAoG8eb/QuBr/zH2LZYogo 2026-06-27T05:24:03Z 9008 1320 15 http://arxiv.org/abs/2412.19511v3 Uncertainty quantification for improving radiomic-based models in radiation pneumonitis prediction 2025-05-21T13:00:56Z Background: Radiation pneumonitis is a side effect of thoracic radiation therapy. Recently, machine learning models with radiomic features have improved radiation pneumonitis prediction by capturing spatial information. To further support clinical decision-making, this study explores the role of post hoc uncertainty quantification methods in enhancing model uncertainty estimate. Methods: We retrospectively analyzed a cohort of 101 esophageal cancer patients. This study evaluated four machine learning models: logistic regression, support vector machines, extreme gradient boosting, and random forest, using 15 dosimetric, 79 dosiomic, and 237 radiomic features to predict radiation pneumonitis. We applied uncertainty quantification methods, including Platt scaling, isotonic regression, Venn-ABERS predictor, and conformal prediction, to quantify uncertainty. Model performance was assessed through an area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and adaptive calibration error using leave-one-out cross-validation. Results: Highest AUROC is achieved by the logistic regression model with the conformal prediction method (AUROC 0.75+-0.01, AUPRC 0.74+-0.01) at a certainty cut point of 0.8. Highest AUPRC of 0.82+-0.02 (with AUROC of 0.67+-0.04) achieved by The extreme gradient boosting model with conformal prediction at the 0.9 certainty threshold. Radiomic and dosiomic features improve both discriminative and calibration performance. Conclusions: Integrating uncertainty quantification into machine learning models with radiomic and dosiomic features may improve both predictive accuracy and calibration, supporting more reliable clinical decision-making. The findings emphasize the value of uncertainty quantification methods in enhancing applicability of predictive models for radiation pneumonitis in healthcare settings. 2024-12-27T08:01:42Z Chanon Puttanawarut Romen Samuel Wabina Nat Sirirutbunkajorn http://arxiv.org/abs/2505.14854v1 Virtual Fluoroscopy for Interventional Guidance using Magnetic Tracking 2025-05-20T19:33:14Z Purpose: In conventional fluoroscopy-guided interventions, the 2D projective nature of X-ray imaging limits depth perception and leads to prolonged radiation exposure. Virtual fluoroscopy, combined with spatially tracked surgical instruments, is a promising strategy to mitigate these limitations. While magnetic tracking shows unique advantages, particularly in tracking flexible instruments, it remains under-explored due to interference from ferromagnetic materials in the C-arm room. This work proposes a virtual fluoroscopy workflow by effectively integrating magnetic tracking, and demonstrates its clinical efficacy. Methods: An automatic virtual fluoroscopy workflow was developed using a radiolucent tabletop field generator prototype. Specifically, we developed a fluoro-CT registration approach with automatic 2D-3D shared landmark correspondence to establish the C-arm-patient relationship, along with a general C-arm modelling approach to calculate desired poses and generate corresponding virtual fluoroscopic images. Results: Testing on a dataset with views ranging from RAO 90 degrees to LAO 90 degrees, simulated fluoroscopic images showed visually imperceptible differences from the real ones, achieving a mean target projection distance error of 1.55 mm. An endoleak phantom insertion experiment highlighted the effectiveness of simulating multiplanar views with real-time instrument overlays, achieving a mean needle tip error of 3.42 mm. Conclusions: Results demonstrated the efficacy of virtual fluoroscopy integrated with magnetic tracking, improving depth perception during navigation. The broad capture range of virtual fluoroscopy showed promise in improving the users understanding of X-ray imaging principles, facilitating more efficient image acquisition. 2025-05-20T19:33:14Z 16 pages, 8 figures, 2025 IPCAI conference Shuwei Xing Inaara Ahmed-Fazal Utsav Pardasani Uditha Jayarathne Scott Illsley Aaron Fenster Terry M. Peters Elvis C. S. Chen http://arxiv.org/abs/2505.14507v1 Federated prediction for scalable and privacy-preserved knowledge-based planning in radiotherapy 2025-05-20T15:35:49Z Background: Deep learning has potential to improve the efficiency and consistency of radiation therapy planning, but clinical adoption is hindered by the limited model generalizability due to data scarcity and heterogeneity among institutions. Although aggregating data from different institutions could alleviate this problem, data sharing is a practical challenge due to concerns about patient data privacy and other technical obstacles. Purpose: This work aims to address this dilemma by developing FedKBP+, a comprehensive federated learning (FL) platform for predictive tasks in real-world applications in radiotherapy treatment planning. Methods: We implemented a unified communication stack based on Google Remote Procedure Call (gRPC) to support communication between participants whether located on the same workstation or distributed across multiple workstations. In addition to supporting the centralized FL strategies commonly available in existing open-source frameworks, FedKBP+ also provides a fully decentralized FL model where participants directly exchange model weights to each other through Peer-to-Peer communication. We evaluated FedKBP+ on three predictive tasks using scale-attention network (SA-Net) as the predictive model. Conclusions: Our results demonstrate that FedKBP+ is highly effective, efficient and robust, showing great potential as a federated learning platform for radiation therapy. 2025-05-20T15:35:49Z Under review for publication by the journal of Medical Physics Jingyun Chen David Horowitz Yading Yuan http://arxiv.org/abs/2505.14075v1 High-energy X-ray phase-contrast CT of an adult human chest phantom 2025-05-20T08:33:25Z Propagation-based phase-contrast X-ray imaging is a promising technique for in~vivo medical imaging, offering lower radiation doses than traditional attenuation-based imaging. Previous studies have focused on X-ray energies below 50 keV for small-animal imaging and mammography. Here, we investigate the feasibility of high-energy propagation-based computed tomography for human adult-scale lung imaging at the Australian Synchrotron's Imaging and Medical Beamline. This facility is uniquely positioned for human lung imaging, offering a large field of view, high X-ray energies, and supporting clinical infrastructure. We imaged an anthropomorphic chest phantom (LungMan) between 50 keV and 80 keV across the range of possible sample-to-detector distances, with a photon-counting and an integrating detector. Strong phase-contrast fringes were observed with the photon-counting detector, even at high X-ray energies and a large pixel size relative to previous work, whereas the integrating detector with lower spatial resolution showed no clear phase effects. Measured X-ray phase-shifting properties of LungMan aligned well with reference soft tissue values, validating the phantom for phase-contrast studies. Imaging quality assessments suggest an optimal configuration at approximately 70 keV and the longest available propagation distance of 7.5 m, indicating potential benefit in positioning the patient in an upstream hutch. This study represents the first step towards clinical adult lung imaging at the Australian Synchrotron. 2025-05-20T08:33:25Z 19 pages, 10 figures Scientific Reports 15, 29314 (2025) Jannis N. Ahlers Lorenzo D'Amico Henriette Bast Lucy F. Costello Martin Donnelley Samantha J. Alloo Stephanie A. Harker Ying Ying How Michelle K. Croughan James A. Pollock Daniel Hausermann Anton Maksimenko Christopher Hall Timur E. Gureyev Yakov I. Nesterets Marcus J. Kitchen Konstantin M. Pavlov Kaye S. Morgan 10.1038/s41598-025-14956-3 http://arxiv.org/abs/2505.08679v2 A fully flexible joint lattice position and dose optimization method for LATTICE therapy 2025-05-20T02:46:39Z Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high doses to tumor regions while sparing surrounding tissues. Traditional LATTICE uses rigid vertex patterns, limiting adaptability for irregular tumors or those near critical organs. This study introduces a novel planning method with flexible vertex placement and joint optimization of vertex positions and dose distribution, enhancing treatment precision. The method integrates vertex positioning with other treatment variables within a constrained optimization framework, allowing dynamic adjustments. Results showed that plans generated with the new method (NEW) demonstrated superior or comparable quality to conventional LATTICE plans, with improvements in the optimization objective and peak-to-valley dose ratio (PVDR). This approach offers significant improvements in target dose conformity and OAR sparing, providing an enhanced LATTICE technique. 2025-05-13T15:41:22Z Xin Tong Weijie Zhang Ya-Nan Zhu Xue Hong Chao Wang Jufri Setianegara Yuting Lin Hao Gao http://arxiv.org/abs/2505.14722v1 ComBAT Harmonization for diffusion MRI: Challenges and Best Practices 2025-05-19T15:58:33Z Over the years, ComBAT has become the standard method for harmonizing MRI-derived measurements, with its ability to compensate for site-related additive and multiplicative biases while preserving biological variability. However, ComBAT relies on a set of assumptions that, when violated, can result in flawed harmonization. In this paper, we thoroughly review ComBAT's mathematical foundation, outlining these assumptions, and exploring their implications for the demographic composition necessary for optimal results. Through a series of experiments involving a slightly modified version of ComBAT called Pairwise-ComBAT tailored for normative modeling applications, we assess the impact of various population characteristics, including population size, age distribution, the absence of certain covariates, and the magnitude of additive and multiplicative factors. Based on these experiments, we present five essential recommendations that should be carefully considered to enhance consistency and supporting reproducibility, two essential factors for open science, collaborative research, and real-life clinical deployment. 2025-05-19T15:58:33Z Pierre-Marc Jodoin Manon Edde Gabriel Girard Félix Dumais Guillaume Theaud Matthieu Dumont Jean-Christophe Houde Yoan David Maxime Descoteaux http://arxiv.org/abs/2505.05144v3 Output correction factors in a 1.5 T magnetic field determined at the central axis and at the lateral dose maximum for five detectors using alanine 2025-05-19T14:33:11Z In recent literature, the output correction factor in a 1.5T magnetic field, kB,Q,Clin, were determined only for the central axis (CAX), including our last work. At an MR-linac, the determination of the CAX position relies on e.g. MV-imaging and is at small field sizes located at the penumbra, whereas the maximum of the lateral profile (MAX) position is directly measurable. This study determined kB,Q,Ratio - the influence of the magnetic field on the output correction factor without a magnetic field, kQ,Clin - and kB,Q,Clin for both CAX and MAX fully experimentally for two MR-optimized ionization chambers, their conventional counterparts, and a solid-state detector. Additionally, the uncertainty due to intra-type variation for tabulated kB,Q,Clin was estimated. Measurements were conducted using an experimental setup consisting of a mobile electromagnet positioned in front of a standard clinical linac (6MV, 1.5T). Intra-type variation for the solid-state detector was assessed using 4 detectors. The change of absorbed dose to water was determined with alanine. Within the uncertainty, no difference in kB,Q,Ratio was observed between the MR-optimized chambers and their conventional counterparts. For the solid-state detector, no difference between CAX and MAX was observed. For all detectors, kB,Q,Clin remained constant down to a field size of 2.5x2.5cm2. At smaller field sizes, for MAX and for all detectors, kB,Q,Ratio decreased linearly. The maximum intra-type variation standard uncertainty was 0.009 for the smallest field size, with and without a magnetic field. In summary, kB,Q,Ratio and kB,Q,Clin, including its uncertainty, was successfully determined for five detectors at both CAX and MAX. For ionization chambers, kB,Q,Clin is lower at MAX, whereas for the solid-state detector, it remains the same. For the tabulated correction factors uncertainty, intra-type variation must be considered. 2025-05-08T11:28:49Z 23 pages, 6 figures, 1 table, 3 page of supplementary material Stephan Frick Daniela Thorwarth Thomas Hackel Ralf-Peter Kapsch http://arxiv.org/abs/2505.13015v1 A flexible approach for fat-water separation with bipolar readouts and correction of gradient-induced phase and amplitude effects 2025-05-19T11:59:44Z Purpose: To develop a fat-water separation approach that corrects bipolar readout gradient induced effects, without additional scans, that is compatible with any fat-water separation method. Theory and Methods: The proposed approach combines joint fat-water separation of the odd and even echoes of a bipolar multi-echo gradient echo acquisition with an inverse problem to find least-squares estimates for phase and amplitude corrections to eliminate bipolar-induced effects. Optimization of sequence parameter selection through the calculation of the number of signal averages (NSA) with Cramér-Rao Bound theory (CRB) is presented. The application of the proposed approach is demonstrated with a graph cut optimization and further characterization of the accuracy was performed via Monte Carlo Simulations (MC). The proposed approach was tested in phantoms and in vivo. Proton density fat fraction maps (PDFF) were evaluated to quantify performance. Results: NSA calculations suggest short TE1 and ΔTE=1.5 ms as optimal alternatives for fat-water separation. MC simulations demonstrated accurate estimation of fat and water complex signals, ψ, and R_2^* with mean relative error within 1%. In phantoms and in vivo, the proposed approach effectively eliminated effects induced by bipolar readout gradients, improving the outcome of the fat-water separation. Conclusion: We proposed an approach to correct bipolar readout-induced effects that are detrimental for fat-water separation. This approach can extend the use of existing fat-water separation techniques designed for data acquired using unipolar readout gradients to data collected with bipolar readout gradients. 2025-05-19T11:59:44Z Jorge Campos Pazmino Renée-Claude Bider Véronique Fortier Ives R. Levesque http://arxiv.org/abs/2505.13536v1 Investigating the Impact of Arterial Irregularity On Clinical Parameters Using Reduced Order CFD Models In Stenosed Coronary Artery 2025-05-18T16:23:55Z Coronary heart disease (CHD) remains a leading cause of mortality worldwide. This study introduces a novel approach that integrates patient-specific Multi-slice CT scans into CAD models, using a one-dimensional numerical framework to assess varying degrees of coronary artery stenosis. The computational analysis encompasses the entire arterial tree, with a particular focus on stenosed coronary arteries modeled analytically. Key parameters, such as area and velocity, are derived from one-dimensional characteristic equations based on forward and backward characteristic variables. A resistance model with zero reflection coefficient and realistic pressure waveform inputs is applied at the outflow and inflow, respectively. The global characteristics captured by the 1D model serve as boundary conditions for a 2D axisymmetric model that focuses on local characteristics. The numerical solvers are validated against existing literature, ensuring grid independence. Fractional Flow Reserve (FFR) and Instantaneous wave-free Ratio (iFR) are calculated using various non-Newtonian models across different stenosis severities. The study also investigates the impact of lesion irregularity in stenosed coronary arteries, finding that irregular arteries exhibit lower FFR and iFR values and higher pressure drops, indicating increased blood flow resistance. This method provides a reliable, non-invasive diagnostic tool for evaluating the functional severity of irregular coronary artery stenosis in clinical settings, effectively capturing both global and local hemodynamic characteristics. 2025-05-18T16:23:55Z arXiv admin note: substantial text overlap with arXiv:2505.12485 Priyanshu Ghosh Sayan Karmakar Disha Mondal Oeshee Roy Supratim Saha http://arxiv.org/abs/2505.11735v1 Evaluation and optimization of deep learning models for enhanced detection of brain cancer using transmission optical microscopy of thin brain tissue samples 2025-05-16T22:45:48Z Optical transmission spectroscopy is one method to understand brain tissue structural properties from brain tissue biopsy samples, yet manual interpretation is resource intensive and prone to inter observer variability. Deep convolutional neural networks (CNNs) offer automated feature learning directly from raw brightfield images. Here, we evaluate ResNet50 and DenseNet121 on a curated dataset of 2,931 bright-field transmission optical microscopy images of thin brain tissue, split into 1,996 for training, 437 for validation, and 498 for testing. Our two stage transfer learning protocol involves initial training of a classifier head on frozen pretrained feature extractors, followed by fine tuning of deeper convolutional blocks with extensive data augmentation (rotations, flips, intensity jitter) and early stopping. DenseNet121 achieves 88.35 percent test accuracy, 0.9614 precision, 0.8667 recall, and 0.9116 F1 score the best performance compared to ResNet50 (82.12 percent, 0.9035, 0.8142, 0.8563). Detailed analysis of confusion matrices, training and validation curves, and classwise prediction distributions illustrates robust convergence and minimal bias. These findings demonstrate the superior generalization of dense connectivity on limited medical datasets and outline future directions for multi-class tumor grading and clinical translation. 2025-05-16T22:45:48Z 10 pages, 5 figures Mohnish Sao Mousa Alrubayan Prabhakar Pradhan http://arxiv.org/abs/2505.11096v1 Determining the utility of ultrafast nonlinear contrast enhanced and super resolution ultrasound for imaging microcirculation in the human small intestine 2025-05-16T10:28:17Z The regulation of intestinal blood flow is critical to gastrointestinal function. Imaging the intestinal mucosal micro-circulation in vivo has the potential to provide new insight into the gut physiology and pathophysiology. We aimed to determine whether ultrafast contrast enhanced ultrasound (CEUS) and super-resolution ultrasound localisation microscopy (SRUS/ULM) could be a useful tool for imaging the small intestine microcirculation in vivo non-invasively and for detecting changes in blood flow in the duodenum. Ultrafast CEUS and SRUS/ULM were used to image the small intestinal microcirculation in a cohort of 20 healthy volunteers (BMI<25). Participants were imaged while conscious and either having been fasted, or following ingestion of a liquid meal or water control, or under acute stress. For the first time we have performed ultrafast CEUS and ULM on the human small intestine, providing unprecedented resolution images of the intestinal microcirculation. We evaluated flow speed inside small vessels in healthy volunteers (2.78 +/- 0.05 mm/s, mean +/- SEM) and quantified changes in the perfusion of this microcirculation in response to nutrient ingestion. Perfusion of the microvasculature of the intestinal mucosa significantly increased post-prandially (36.2% +/- 12.2%, mean +/- SEM, p<0.05). The feasibility of 3D SRUS/ULM was also demonstrated. This study demonstrates the potential utility of ultrafast CEUS for assessing perfusion and detecting changes in blood flow in the duodenum. SRUS/ULM also proved a useful tool to image the microvascular blood flow in vivo non-invasively and to evaluate blood speed inside the microvasculature of the human small intestine. 2025-05-16T10:28:17Z Clotilde Vié Martina Tashkova James Burn Matthieu Toulemonde Jipeng Yan Jingwen Zhu Cameron A. B. Smith Biao Huang Su Yan Kevin G. Murphy Gary Frost Meng-Xing Tang http://arxiv.org/abs/2501.10608v2 Novel Direct Alpha Spectroscopy Technique for $^{225}$Ac Radiopharmaceutical detection in Cancer Cells 2025-05-16T00:10:36Z Targeted alpha-particle therapy (TAT) employs alpha-emitting radionuclides conjugated to tumor-targeting molecules to deliver localized radiation to cancer cells, showing great promise in treating metastatic cancers. Among these radionuclides, Actinium-225 ($^{225}$Ac, t$_{1/2}$ = 9.9 days) has emerged as a clinically promising candidate. Its decay chain generates four successive alpha emissions, resulting in highly localized and effective cytotoxic damage to cancer cells when delivered to tumor sites. However, the assumption of complete retention of $^{225}$Ac and its radioactive daughters at these target sites is often inaccurate. The nuclear recoil effect can lead to off-target distribution and unintended toxicity. Our results revealed distinct spectral differences between radiolabeled cells and reference samples, demonstrating [$^{225}$Ac]Ac-crown-TATE uptake by AR42J cells. Detection of $^{213}$Po, one of the $^{225}$Ac decay daughters, highlighted partial retention and release of decay products from cells, providing information on intracellular retention and daughter redistribution. Geant4 simulations confirmed the alignment of experimental data with theoretical models, validating the method's accuracy. This study establishes a direct alpha spectroscopy approach for investigating $^{225}$Ac and its daughters' behavior in cells and offers a powerful tool for microdosimetry estimation. 2025-01-17T23:57:43Z Mahsa Farasat Behrad Saeedi Luke Wharton Sidney Shapiro Chris Vinnick Madison Daignault Meghan Kostashuk Nicholas Pranjatno Myla Weiman Corina Andreoiu Hua Yang Peter Kunz http://arxiv.org/abs/2505.10731v1 A reconstruction algorithm of electrical impedance tomography based on one-dimensional convolutional neural network 2025-05-15T22:21:06Z Electrical impedance tomography (EIT) is a novel computational imaging technology. In order to improve the quality and spatial resolution of the reconstructed images, the G-CNN and HG-CNN algorithms are proposed based on a one-dimensional convolutional neural network (1D-CNN) in this paper. The input of the 1D-CNN is the reconstructed conductivity distribution obtained by the GVSPM algorithm or the H-GVSPM algorithm. The reconstructed images with higher resolution are obtained through the calculation of 1D-CNN. Finally, the Hadamard product is applied to calculate the output of the 1D-CNN. In the simulation results of the lung cross-section models, the correlation coefficients of the G-CNN algorithm and HG-CNN algorithm maximumly are 2.52 times and 2.20 times greater than the GVSPM algorithm and H-GVSPM algorithm, respectively. In the results of the simulation and experiment, the reconstructed images of the G-CNN and HG-CNN algorithms are distortion-free. In addition, the artifacts of the reconstructed images are diminished after calculations of the Hadamard product. This research provides a reference method for improving the quality of the reconstructed images so that EIT is better applied in medical detection. 2025-05-15T22:21:06Z Zhenzhong Song Jianping Li Jiafeng Yao Linying Wang Dan Zhu Lvjun Zhang Jianming Wen Nen Wan Jijie Ma Yu Zhang Zengfeng Gao http://arxiv.org/abs/2504.15285v2 AneuPy: An open source Python tool for creating simulation-ready geometries of abdominal aortic aneurysms 2025-05-15T17:59:31Z Abdominal aortic aneurysms (AAAs) are localized dilatations of the abdominal aorta that can lead to life-threatening rupture if left untreated. AAAs primarily affect older individuals, with high mortality rates following rupture, so early diagnosis and risk assessment are critical. The geometrical characteristics of an AAA, such as its maximum diameter, asymmetry, and wall thickness, are extremely significant in biomechanical models for the assessment of rupture risk. Despite the growing use of computational modeling for AAA investigation, there is a notable gap in accessible, open-source software capable of generating simulation-ready geometries for biomechanical and hemodynamic simulations. To address this gap, we introduce \textbf{AneuPy}, an open-source Python-based tool designed to create both idealized and patient-specific AAA geometric models. \textbf{AneuPy} is a fast and automated approach for generating aneurysm geometries from minimal input data, allowing for extensive parameter customization. By automating the creation of simulation-ready geometries for finite element analysis (FEA), computational fluid dynamics (CFD), or fluid-structure interaction (FSI) models, \textbf{AneuPy} can facilitate research in AAA and improve patient-specific risk prediction. 2025-03-13T16:05:32Z 14 pages, 5 figures Mario de Lucio Jacobo Diaz Alberto de Castro Luis E. Romera http://arxiv.org/abs/2505.09993v1 Automated grading and staging of ovarian cancer using deep learning on the transmission optical microscopy bright-field images of thin biopsy tissue samples 2025-05-15T06:06:24Z Ovarian cancer remains a challenging malignancy to diagnose and manage, with prognosis heavily dependent on the stage at detection. Accurate grading and staging, primarily based on histopathological examination of biopsy tissue samples, are crucial for treatment planning and predicting outcomes. However, this manual process is time-consuming and subject to inter-observer variability among pathologists. The increasing volume of digital histopathology slides necessitates the development of robust, automated methods to assist in this critical diagnostic step for ovarian cancer. (Methods) This study presents a deep learning framework for the automated prediction of ovarian cancer stage (classified into five categories: 0, I, II, III, IV) using routine histopathological images. We employed a transfer learning approach, fine-tuning a ResNet-101 convolutional neural network pre-trained on ImageNet. The training process incorporated comprehensive data augmentation, weighted random sampling, and class weighting to address dataset characteristics. Hyperparameter optimization for learning rate, dropout rate, and weight decay was performed using a genetic algorithm to enhance model performance and generalization. (Results) Evaluated on an independent test set of ovarian thin tissue brightfield images, the developed model achieved a high overall classification accuracy of 97.62%. 2025-05-15T06:06:24Z 5 figures, 15 pages Ashmit K Mishra Mousa Alrubayan Prabhakar Pradhan