https://arxiv.org/api/1C9sZonNidZAtII1fBpr7zIhUmY 2026-06-27T03:19:02Z 9008 1290 15 http://arxiv.org/abs/2505.24136v1 Sparsity-Driven Parallel Imaging Consistency for Improved Self-Supervised MRI Reconstruction 2025-05-30T02:11:25Z Physics-driven deep learning (PD-DL) models have proven to be a powerful approach for improved reconstruction of rapid MRI scans. In order to train these models in scenarios where fully-sampled reference data is unavailable, self-supervised learning has gained prominence. However, its application at high acceleration rates frequently introduces artifacts, compromising image fidelity. To mitigate this shortcoming, we propose a novel way to train PD-DL networks via carefully-designed perturbations. In particular, we enhance the k-space masking idea of conventional self-supervised learning with a novel consistency term that assesses the model's ability to accurately predict the added perturbations in a sparse domain, leading to more reliable and artifact-free reconstructions. The results obtained from the fastMRI knee and brain datasets show that the proposed training strategy effectively reduces aliasing artifacts and mitigates noise amplification at high acceleration rates, outperforming state-of-the-art self-supervised methods both visually and quantitatively. 2025-05-30T02:11:25Z IEEE International Conference on Image Processing (ICIP), 2025 Yaşar Utku Alçalar Mehmet Akçakaya 10.1109/ICIP55913.2025.11084355 http://arxiv.org/abs/2505.23882v1 Motility-dependent selective transport of active matter in trap arrays: Separation methods based on trapping-detrapping and deterministic lateral displacement 2025-05-29T17:46:15Z Selecting active matter based on its motility represents a challenging task, as it requires different approaches than common separation techniques intended for separation based on, e.g., size, shape, density, and flexibility. This motility-based selection is important for, e.g., selecting biological species, such as bacteria or highly motile sperm cells for medically assisted reproduction. Common separation techniques are not applicable for separating species based on motility as such species can have indistinguishable physical properties, i.e., size, shape, density, and differ only by their ability to execute self-propelled motion as, e.g., motile, and immotile sperm cells. Therefore, selecting active species based on motility requires completely different approaches. Some of these have been developed including sperm cell selection techniques, e.g., swim-up techniques, passive selection methods based on the ability of highly motile sperm cells to swim across streamlines, as well as more sophisticated techniques. Here we theoretically demonstrate via numerical simulations various efficient methods of selection and separation based on the motility of active species using arrays of traps. Two approaches are proposed: one allowed the selective escape of motile species from traps, and the other one relying on a deterministic lateral displacement (DLD)-type method. As a model system, we consider self-propelled Janus particles whose motility can be tuned. The resulted separation methods are applicable for separation of biological motile species, such as bacteria or sperm cells, as well as for Janus micro- and nanoparticles. 2025-05-29T17:46:15Z 20 pages, 8 figures (preliminary version; journal version contains also "Supporting Information'' file) Nanoscale 17, 13434 - 13446 (2025) Vyacheslav R. Misko Franco Nori Wim De Malsche 10.1039/d5nr00675a http://arxiv.org/abs/2505.20358v2 Is GGAG:Ce@SiO$_2$-RB composite a prospective material for X-ray induced photodynamic therapy? 2025-05-29T10:37:22Z Nanocomposite material ($\mathrm{GGAG:Ce^{3+}@SiO_2-RB}$) for potential use in X-ray induced photodynamic therapy (X-PDT) was developed, thoroughly characterized, and evaluated. It consists of a scintillating $\mathrm{Gd_3(Ga_{1-x}Al_x)_5O_{12}:Ce^{3+}}$ core encapsulated in silica layer and functionalized with the photosensitizer Rose Bengal (RB). Radioluminescence measurements confirmed the energy transfer from the scintillating core to Rose Bengal. Dark toxicity and radiosensitisation effects were evaluated using Saccharomyces cerevisiae as a model organism. The nanocomposite showed minimal dark toxicity at concentrations of up to 10 mg/mL. However, X-ray irradiation experiments did not demonstrate significant singlet oxygen production compared to the controls. Although the nanocomposite design shows potential, further optimization is needed to achieve an effective X-PDT performance. 2025-05-26T07:38:05Z 23 pages, 7 figures Iveta Terezie Hošnová Kristýna Havlinová Jan Bárta Karolína Mocová Xenie Lytvynenko Lenka Prouzová Procházková Vojtěch Kazda František Hájek Viliam Múčka Václav Čuba 10.1016/j.radphyschem.2025.112942 http://arxiv.org/abs/2505.22797v1 Fast Trajectory-Independent Model-Based Reconstruction Algorithm for Multi-Dimensional Magnetic Particle Imaging 2025-05-28T19:13:46Z Magnetic Particle Imaging (MPI) is a promising tomographic technique for visualizing the spatio-temporal distribution of superparamagnetic nanoparticles, with applications ranging from cancer detection to real-time cardiovascular monitoring. Traditional MPI reconstruction relies on either time-consuming calibration (measured system matrix) or model-based simulation of the forward operator. Recent developments have shown the applicability of Chebyshev polynomials to multi-dimensional Lissajous Field-Free Point (FFP) scans. This method is bound to the particular choice of sinusoidal scanning trajectories. In this paper, we present the first reconstruction on real 2D MPI data with a trajectory-independent model-based MPI reconstruction algorithm. We further develop the zero-shot Plug-and-Play (PnP) algorithm of the authors -- with automatic noise level estimation -- to address the present deconvolution problem, leveraging a state-of-the-art denoiser trained on natural images without retraining on MPI-specific data. We evaluate our method on the publicly available 2D FFP MPI dataset ``MPIdata: Equilibrium Model with Anisotropy", featuring scans of six phantoms acquired using a Bruker preclinical scanner. Moreover, we show reconstruction performed on custom data on a 2D scanner with additional high-frequency excitation field and partial data. Our results demonstrate strong reconstruction capabilities across different scanning scenarios -- setting a precedent for general-purpose, flexible model-based MPI reconstruction. 2025-05-28T19:13:46Z 10 pages, 5 figures. This work has been submitted to the IEEE for possible publication Phys. Med. Biol. 70 (2025) 235028 Vladyslav Gapyak Thomas März Andreas Weinmann 10.1088/1361-6560/ae205c http://arxiv.org/abs/2505.21853v1 Quantitative Macromolecular Proton Fraction Imaging using Pulsed Spin-Lock 2025-05-28T00:53:45Z Purpose: Recent studies have shown that spin-lock MRI can simplify quantitative magnetization transfer (MT) by eliminating its dependency on water pool parameters, removing the need for a T1 map in macromolecular proton fraction (MPF) quantification. However, its application is often limited by the requirement for long radiofrequency (RF) pulse durations, which are constrained by RF hardware capabilities despite remaining within specific absorption rate (SAR) safety limits. Methods: To address this challenge, we propose a novel method, MPF mapping using pulsed spin-lock (MPF-PSL). MPF-PSL employs a pulsed spin-lock train with intermittent free precession periods, enabling extended total spin-lock durations without exceeding hardware and specific absorption rate limits. A comprehensive analytical framework was developed to model the magnetization dynamics of the two-pool MT system under pulsed spin-lock, demonstrating that MPF-PSL achieves MT-specific quantification while minimizing confounding effects from the water pool. The proposed method is validated with Bloch-McConnell simulations, phantoms, and in vivo studies at 3T. Results: Both Bloch-McConnell simulations and phantom validation demonstrated that MPF-PSL exhibits robust insensitivity to water pool parameters while enabling high-SNR MPF quantification. In vivo validation studies confirmed the method's clinical utility in detecting collagen deposition in patients with liver fibrosis. Conclusion: MPF-PSL presents a practical solution for quantitative MT imaging, with strong potential for clinical applications. 2025-05-28T00:53:45Z 15 pages, 10 figures; Qianxue Shan and Ziqiang Yu contributed equally to this work Qianxue Shan Department of Imaging and Interventional Radiology Ziqiang Yu Department of Imaging and Interventional Radiology Baiyan Jiang Department of Imaging and Interventional Radiology Illumination Medical Technology Limited Jian Hou Department of Imaging and Interventional Radiology Qiuyi Shen Department of Imaging and Interventional Radiology Winnie CW Chu Department of Imaging and Interventional Radiology Vincent WS Wong Department of Medicine and Therapeutics Weitian Chen Department of Imaging and Interventional Radiology http://arxiv.org/abs/2505.21745v1 Design and performance of a Toroidal RF Volume Coil with Intrinsic Electromagnetic Interference Rejection for low-field Portable Halbach-Based MRI Systems 2025-05-27T20:34:18Z Purpose: One of the intrinsic limitations of low-field MRI is low signal-to-noise ratio (SNR), which can be further reduced by electromagnetic interference (EMI) due to the lack of a Faraday shielded room. To address this issue, we propose a novel RF coil design that is inherently less sensitive to EMI while maintaining high receive sensitivity. Methods: The proposed coil structure is based on an anapole (toroidal) design and consists of six rings, each containing four continuous wires wound around an elliptical 3D-printed former. The wire in the entire structure is uninterrupted. This coil is designed for use in systems with an axial B0 field direction. The performance of the proposed RF coil was evaluated on a Halbach array system designed for neuroimaging and operating at 47mT and compared with a widely used spiral head coil. Results: The noise level achieved by the proposed toroidal coil in combination with a belt wrapped around the subjects and grounded to the scanner was comparable to that of the widely used spiral head coil when combined with a grounding belt and passive aluminum shielding. The coil transmit and receive efficiency was comparable to the efficiency of the spiral head coil. Conclusion: The proposed RF coil inherently reduces the effect of EMI, potentially removing or reducing the need for passive shielding or external/internal sensors for EMI reduction in post-processing. 2025-05-27T20:34:18Z 20 pages, 6 figures. Magn Reson Med. 2025 Jules Vliem Electrical Engineering Department, Eindhoven University of Technology, Eindhoven, The Netherlands Najac Chloe C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands Beatrice Lena C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands Andrew Webb C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands Irena Zivkovic Electrical Engineering Department, Eindhoven University of Technology, Eindhoven, The Netherlands 10.1002/mrm.70095 http://arxiv.org/abs/2501.00256v4 Rapid, High-resolution and Distortion-free $R_{2}^{*}$ Mapping of Fetal Brain using Multi-echo Radial FLASH and Model-based Reconstruction 2025-05-27T18:54:39Z Purpose: To develop a rapid, high-resolution and distortion-free technique for simultaneous water-fat separation, $R_{2}^{*}$ and $B_{0}$ mapping of the fetal brain at 3T. Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from k-space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age. Results: Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model-based reconstruction yields quantitative $R_{2}^{*}$ values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra-class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi-echo EPI, the proposed radial technique produces higher-resolution (1.1 $\times$ 1.1 $\times$ 3 mm$^{3}$ vs. 2-3 $\times$ 2-3 $\times$ 3 mm$^{3}$) $R_{2}^{*}$ maps with reduced distortion. Despite of differences in motion, resolution and distortion, $R_{2}^{*}$ values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables synthesis of high-resolution and distortion-free $R_{2}^{*}$-weighted images. Conclusion: This study demonstrates the feasibility of using multi-echo radial FLASH combined with calibrationless model-based reconstruction for motion-robust, distortion-free $R_{2}^{*}$ mapping of the fetal brain at 3T, achieving a nominal resolution of $1.1 \times 1.1 \times 3$ mm$^{3}$ within 2 seconds per slice. 2024-12-31T03:54:53Z Part of this work has been presented at the ISMRM, 2024, Singapore and ISMRM 2025, Honolulu. Accepted by Magnetic Resonance in Medicine (May 2025) Magnetic Resonance in Medicine 2025;94:1913-1929 Xiaoqing Wang Hongli Fan Zhengguo Tan Serge Vasylechko Edward Yang Ryne Didier Onur Afacan Martin Uecker Simon K. Warfield Ali Gholipour 10.1002/mrm.30604 http://arxiv.org/abs/2505.21183v1 Radionuclide Production for Dose Verification in VHEE FLASH Radiotherapy 2025-05-27T13:33:48Z This study explores the production of radionuclides in a PMMA (Polymethylmethacrylate) phantom irradiated with Very High Energy Electrons (VHEE) beams as a novel method for dose verification. In this work, Monte Carlo simulation studies using the Geant4 toolkit and experimental measurements with a VHEE beam produced by a laser-plasma accelerator were conducted. Specifically, the photonuclear production of 11C, 15O and 13N is examined, with a detailed analysis of their spatial distribution, production yields and decay time 2025-05-27T13:33:48Z Submitted to Nuclear Instruments and Methods in Physics Research Section A Proceedings(VCI2025) Francesco Urso Federica Baffigi Esther Ciarrocchi Leonida Antonio Gizzi Petra Koester Luca Labate Matteo Morrocchi Simona Piccinini Martina Salvadori Maria Giuseppina Bisogni http://arxiv.org/abs/2505.21139v1 Identifying Heart Attack Risk in Vulnerable Population: A Machine Learning Approach 2025-05-27T12:51:04Z The COVID-19 pandemic has significantly increased the incidence of post-infection cardiovascular events, particularly myocardial infarction, in individuals over 40. While the underlying mechanisms remain elusive, this study employs a hybrid machine learning approach to analyze epidemiological data in assessing 13 key heart attack risk factors and their susceptibility. Based on a unique dataset that combines demographic, biochemical, ECG, and thallium stress-tests, this study categorizes distinct subpopulations against varying risk profiles and then divides the population into 'at-risk' (AR) and 'not-at-risk' (NAR) groups using clustering algorithms. The study reveals strong association between the likelihood of experiencing a heart attack on the 13 risk factors studied. The aggravated risk for postmenopausal patients indicates compromised individual risk factors due to estrogen depletion that may be, further compromised by extraneous stress impacts, like anxiety and fear, aspects that have traditionally eluded data modeling predictions. 2025-05-27T12:51:04Z 16 pages, 2 figures, 7 tables Information 2025, 16, 265 Subhagata Chattopadhyay Amit K Chattopadhyay 10.3390/info16040265 http://arxiv.org/abs/2505.21094v1 Hybrid Machine Learning and Mathematical Modeling for Tumor Dynamics Prediction: Comparing SPIONs against mNP-FDG 2025-05-27T12:21:05Z This is a Machine Learning guided study towards zone-specific ray therapy. Combining Machine Learning (Extreme Gradient Boosting) with continuum modeling (exponential and logistic growth), we find that while fluorodeoxyglucose-coated (mNP-FDG) can control cancerous tumor progression within 2 days compared to 18 days by Superparamagnetic Iron Oxide Nanoparticles (SPIONs), for complete termination of the tumor, SPIONS (20 days) are superior compared to mNP-FDG (more than 40 days). We also provide an interactive graphical user interface (GUI) developed with Tkinter/Python that allows users to input relevant data, such as treatment type and time, to receive real-time tumor volume predictions. Our ML-guided prediction indicates joint therapy as the optimum choice, with mNP-FDG ideal for taming the tumor spread, followed by SPIONs for complete eradication, facilitating personalized cancer treatment in clinical practice. 2025-05-27T12:21:05Z 8 pages, 7 figures Annals of Biostatistics and Biometric Applications 6(3): 2025 Amit K Chattopadhyay Aimee Pascaline N Unkundiye Gillian Pearce 10.33552/ABBA.2025.06.000639 http://arxiv.org/abs/2505.21080v1 Decoding Breast Cancer in X-ray Mammograms: A Multi-Parameter Approach Using Fractals, Multifractals, and Structural Disorder Analysis 2025-05-27T12:03:52Z We explored the fractal and multifractal characteristics of breast mammogram micrographs to identify quantitative biomarkers associated with breast cancer progression. In addition to conventional fractal and multifractal analyses, we employed a recently developed fractal-functional distribution method, which transforms fractal measures into Gaussian distributions for more robust statistical interpretation. Given the sparsity of mammogram intensity data, we also analyzed how variations in intensity thresholds, used for binary transformations of the fractal dimension, follow unique trajectories that may serve as novel indicators of disease progression. Our findings demonstrate that fractal, multifractal, and fractal-functional parameters effectively differentiate between benign and cancerous tissue. Furthermore, the threshold-dependent behavior of intensity-based fractal measures presents distinct patterns in cancer cases. To complement these analyses, we applied the Inverse Participation Ratio (IPR) light localization technique to quantify structural disorder at the microscopic level. This multi-parametric approach, integrating spatial complexity and structural disorder metrics, offers a promising framework for enhancing the sensitivity and specificity of breast cancer detection. 2025-05-27T12:03:52Z 16 pages, 10 figures Santanu Maity Mousa Alrubayan Prabhakar Pradhan http://arxiv.org/abs/2505.20093v1 Technical recommendation on multiplex MR elastography for tomographic mapping of abdominal stiffness with a focus on the pancreas and pancreatic ductal adenocarcinoma 2025-05-26T15:04:36Z Objectives: MR elastography (MRE) offers valuable mechanical tissue characterization, however, in deep abdominal organs like the pancreas conventional single-driver, single-frequency approaches often fail. This study evaluates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations. Methods: This study used single-shot spin-echo MRE in 18 healthy volunteers targeting the liver, pancreas, kidneys, and spleen. Each healthy volunteer underwent 16 MRE examinations with different sets of four vibration frequencies (30-60 Hz) and four driver combinations, and an additional null experiment without vibrations. Further, a cohort of 14 patients with pancreatic ductal adenocarcinoma (PDAC) were retrospectively assessed. The quality of shear-wave fields and stiffness maps was assessed by displacement amplitudes and image sharpness. Results: In healthy volunteers, abdominal coverage with displacement amplitudes above the pre-determined noise level of 4 μm varied between MRE configurations: 24.2% ([0.0%-56.2%], single-driver, 60 Hz), 66.9% ([24.8%-97.7%], single-driver, 30-60 Hz), 70.2% ([0.0%-92.5%], multi-driver, 60 Hz) and 99.9% ([89.4%-100%], multi-driver, 30-60 Hz). In the pancreas, >60% coverage was achieved in all subjects using four drivers and multiple frequencies. This was achieved in only 2/18 subjects using single-driver/single-frequency MRE. Patients with PDAC had 99.1% [91.4%-100%] coverage in the pancreas and 96.3% [63.1%-100%] abdominal coverage (multi-driver, 30-60 Hz). Conclusion: MRE with four drivers and multiple vibration frequencies between 30-60 Hz enables tomographic mapping of tissue stiffness across the entire abdomen, including the pancreas. Multiplex MRE offers a promising approach for generating detailed images of abdominal stiffness, potentially enhancing clinical diagnostics for abdominal and pancreatic diseases. 2025-05-26T15:04:36Z 28 pages; Main: 6 figures, 2 tables; Supplemental: 2 figures, 1 table Jakob Schattenfroh Salma Almutawakel Jan Bieling Johannes Castelein Melanie Estrella Philippe Garteiser Viktor Hartung Karl H. Hillebrandt Adrian T. Huber Laura Körner Thomas Kröncke Thomas Malinka Hans-Jonas Meyer Tom Meyer Uwe Pelzer Felix Pfister Igor M. Sauer Anna Speth Bernard E. Van Beers Carsten Warmuth Nienke P. M. Wassenaar Yanglei Wu Rolf Reiter Ingolf Sack 10.1097/RLI.0000000000001231 http://arxiv.org/abs/2406.19239v2 ALMA: a mathematics-driven approach for determining tuning parameters in generalized LASSO problems, with applications to MRI 2025-05-26T14:39:50Z Magnetic Resonance Imaging (MRI) is a powerful technique employed for non-invasive in vivo visualization of internal structures. Sparsity is often deployed to accelerate the signal acquisition or overcome the presence of motion artifacts, improving the quality of image reconstruction. Image reconstruction algorithms use TV-regularized LASSO (Total Variation-regularized LASSO) to retrieve the missing information of undersampled signals, by cleaning the data of noise and while optimizing sparsity. A tuning parameter moderates the balance between these two aspects; its choice affecting the quality of the reconstructions. Currently, there is a lack of general deterministic techniques to choose these parameters, which are oftentimes manually selected and thus hinder the reliability of the reconstructions. Here, we present ALMA (Algorithm for Lagrange Multipliers Approximation), an iterative mathematics-inspired technique that computes tuning parameters for generalized LASSO problems during MRI reconstruction. We analyze quantitatively the performance of these parameters for imaging reconstructions via TV-LASSO in an MRI context on phantoms. Although our study concentrates on TV-LASSO, the techniques developed here hold significant promise for a wide array of applications. ALMA is not only adaptable to more generalized LASSO problems but is also robust to accommodate other forms of regularization beyond total variation. Moreover, it extends effectively to handle non-Cartesian sampling trajectories, broadening its utility in complex data reconstruction scenarios. More generally, ALMA provides a powerful tool for numerically solving constrained optimization problems across various disciplines, offering a versatile and impactful solution for advanced computational challenges. 2024-06-27T15:02:04Z Modified pictures, authors and fixed some typo Gianluca Giacchi Isidoros Iakovidis Bastien Milani Micah Murray Benedetta Franceschiello http://arxiv.org/abs/2505.19513v1 Ring artifacts correction method in x-ray computed tomography based on stripe classification and removal in sinogram images 2025-05-26T04:56:37Z X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with ring artifacts being a common occurrence that significantly compromises image quality and subsequent structural interpretation. In this study, a ring artifact correction method based on stripe classification and removal in sinogram images was proposed. The proposed method classifies ring artifacts into single stripes and multiple stripes, which were identified and eliminated using median filtering and multiphase decomposition, respectively. A novel algorithm combining median filtering, polyphase decomposition and median filtering was further developed to eliminate all forms of stripes simultaneously and effectively. The efficacy of the proposed method was validated through both simulated and experimental CT data. The study provides a novel perspective and integrated approach to addressing ring artifacts in X-ray CT. It will be of significant illuminating to a diverse readership, including radiologists, clinical researchers, and industrial scientists. 2025-05-26T04:56:37Z Yang Zou Meili Qi Jianhua Zhang Difei Zhang Shuwei Wang Jiale Zhang Shengkun Yao Huaidong Jiang http://arxiv.org/abs/2505.19226v1 Patient-specific forecasting method for the functionality of a balloon-expandable stent 2025-05-25T16:41:00Z This research aims to develop a method to reduce the time cost and complexity of balloon expandable stent simulations in cardiovascular stenting procedures for Peripheral Artery Disease. The study uses stereoscopic images to construct a cardiovascular stent and validate its mechanical response through Finite Element testing. A 3D model of the curved common femoral artery was constructed using Computed Tomography of a patient with Critical Limb Ischemia. The fatigue life cycles of the stent were estimated considering sinusoidal cyclic loading. The crimping process has a negligible influence on the mechanical response, with recoil and foreshortening percentages remaining static with increasing stent rings. The numerical results indicate the biomechanical influence of stent placement in a realistic vessel and compare it with literature. 2025-05-25T16:41:00Z Efstathios Stratakos Vassilis Kostopoulos Spyridon Psarras