https://arxiv.org/api/n8esueJvKW5ZiCI/kPraIpyjHMY 2026-06-27T02:18:30Z 9008 1275 15 http://arxiv.org/abs/2506.04328v1 Quantum-Inspired Genetic Optimization for Patient Scheduling in Radiation Oncology 2025-06-04T18:00:04Z Among the genetic algorithms generally used for optimization problems in the recent decades, quantum-inspired variants are known for fast and high-fitness convergence and small resource requirement. Here the application to the patient scheduling problem in proton therapy is reported. Quantum chromosomes are tailored to possess the superposed data of patient IDs and gantry statuses. Selection and repair strategies are also elaborated for reliable convergence to a clinically feasible schedule although the employed model is not complex. Clear advantage in population size is shown over the classical counterpart in our numerical results for both a medium-size test case and a large-size practical problem instance. It is, however, observed that program run time is rather long for the large-size practical case, which is due to the limitation of classical emulation and demands the forthcoming true quantum computation. Our results also revalidate the stability of the conventional classical genetic algorithm. 2025-06-04T18:00:04Z 15 pages, 11 figures, 10 tables Akira SaiToh Arezoo Modiri Amit Sawant Robabeh Rahimi http://arxiv.org/abs/2506.03792v1 Analytical Reconstruction of Periodically Deformed Objects in Time-resolved CT 2025-06-04T09:54:30Z Time-resolved CT is an advanced measurement technique that has been widely used to observe dynamic objects, including periodically varying structures such as hearts, lungs, or hearing structures. To reconstruct these objects from CT projections, a common approach is to divide the projections into several collections based on their motion phases and perform reconstruction within each collection, assuming they originate from a static object. This describes the gating-based method, which is the standard approach for time-periodic reconstruction. However, the gating-based reconstruction algorithm only utilizes a limited subset of projections within each collection and ignores the correlation between different collections, leading to inefficient use of the radiation dose. To address this issue, we propose two analytical reconstruction pipelines in this paper, and validate them with experimental data captured using tomographic synchrotron microscopy. We demonstrate that our approaches significantly reduce random noise in the reconstructed images without blurring the sharp features of the observed objects. Equivalently, our methods can achieve the same reconstruction quality as gating-based methods but with a lower radiation dose. Our code is available at github.com/PeriodRecon. 2025-06-04T09:54:30Z Qianwei Qu Christian M. Schlepütz Marco Stampanoni http://arxiv.org/abs/2506.03786v1 Discrete Element Parameter Calibration of Livestock Salt Based on Particle Scaling 2025-06-04T09:47:07Z In order to obtain accurate contact parameters for the discrete element simulation of salt particles used in animal husbandry, the principle of particle contact scaling and dimensional analysis were used for particle scaling. Firstly, the Plackett Burman experiment was used to screen the parameters that significantly affect the angle of repose: salt salt rolling friction coefficient, salt salt recovery coefficient, and salt steel rolling friction coefficient. Considering the influence of other parameters, a combination of bench and simulation experiments was used to calibrate the contact parameters between salt particles and steel plates used in animal husbandry in EDEM. Finally, through the stacking test, steepest climbing test, and orthogonal rotation combination test, the salt salt rolling friction coefficient was obtained to be 0.23, the salt salt recovery coefficient was 0.544, and the salt steel rolling friction coefficient was 0.368, which were verified through bench tests. The experimental results show that the relative error between the actual value of the stacking angle and the simulation results is 0.6%. The results indicate that the calibrated contact parameters can be used for discrete element simulation of salt particles for animal husbandry, providing reference for the design of quantitative feeding screws and silos. 2025-06-04T09:47:07Z Lulu Nie Baoqin Wen Jingbin Li Shufeng Li Yali Li Zhaokun Zhang Zhiyuan Wang Zhihao Fan http://arxiv.org/abs/2412.04339v2 Likelihood-Scheduled Score-Based Generative Modeling for Fully 3D PET Image Reconstruction 2025-06-03T13:27:52Z Medical image reconstruction with pre-trained score-based generative models (SGMs) has advantages over other existing state-of-the-art deep-learned reconstruction methods, including improved resilience to different scanner setups and advanced image distribution modeling. SGM-based reconstruction has recently been applied to simulated positron emission tomography (PET) datasets, showing improved contrast recovery for out-of-distribution lesions relative to the state-of-the-art. However, existing methods for SGM-based reconstruction from PET data suffer from slow reconstruction, burdensome hyperparameter tuning and slice inconsistency effects (in 3D). In this work, we propose a practical methodology for fully 3D reconstruction that accelerates reconstruction and reduces the number of critical hyperparameters by matching the likelihood of an SGM's reverse diffusion process to a current iterate of the maximum-likelihood expectation maximization algorithm. Using the example of low-count reconstruction from simulated [$^{18}$F]DPA-714 datasets, we show our methodology can match or improve on the NRMSE and SSIM of existing state-of-the-art SGM-based PET reconstruction while reducing reconstruction time and the need for hyperparameter tuning. We evaluate our methodology against state-of-the-art supervised and conventional reconstruction algorithms. Finally, we demonstrate a first-ever implementation of SGM-based reconstruction for real 3D PET data, specifically [$^{18}$F]DPA-714 data, where we integrate perpendicular pre-trained SGMs to eliminate slice inconsistency issues. 2024-12-05T16:58:45Z 12 pages, 14 figures. Author's accepted manuscript, IEEE Transactions on Medical Imaging George Webber Yuya Mizuno Oliver D. Howes Alexander Hammers Andrew P. King Andrew J. Reader 10.1109/TMI.2025.3576483 http://arxiv.org/abs/2506.02427v1 Single-Shot, Single-Mask X-ray Dark-field and Phase Contrast Imaging 2025-06-03T04:21:38Z X-ray imaging, traditionally relying on attenuation contrast, struggles to differentiate materials with similar attenuation coefficients like soft tissues. X-ray phase contrast imaging (XPCI) and dark-field (DF) imaging provide enhanced contrast by detecting phase shifts and ultra-small-angle X-ray scattering (USAXS). However, they typically require complex and costly setups, along with multiple exposures to retrieve various contrast features. In this study, we introduce a novel single-mask X-ray imaging system design that simultaneously captures attenuation, differential phase contrast (DPC), and dark-field images in a single exposure. Most importantly, our proposed system design requires just a single mask alignment with relatively low-resolution detectors. Using our novel light transport models derived for these specific system designs, we show intuitive understanding of contrast formation and retrieval method of different contrast features. Our approach eliminates the need for highly coherent X-ray sources, ultra-high-resolution detectors, spectral detectors or intricate gratings. We propose three variations of the single-mask setup, each optimized for different contrast types, offering flexibility and efficiency in a variety of applications. The versatility of this single-mask approach along with the use of befitting light transport models holds promise for broader use in clinical diagnostics and industrial inspection, making advanced X-ray imaging more accessible and cost-effective. 2025-06-03T04:21:38Z 18 pages, 10 figures Jingcheng Yuan Mini Das http://arxiv.org/abs/2506.03202v1 A combined Machine Learning and Finite Element Modelling tool for the surgical planning of craniosynostosis correction 2025-06-02T17:11:50Z Craniosynostosis is a medical condition that affects the growth of babies' heads, caused by an early fusion of cranial sutures. In recent decades, surgical treatments for craniosynostosis have significantly improved, leading to reduced invasiveness, faster recovery, and less blood loss. At Great Ormond Street Hospital (GOSH), the main surgical treatment for patients diagnosed with sagittal craniosynostosis (SC) is spring assisted cranioplasty (SAC). This procedure involves a 15x15 mm2 osteotomy, where two springs are inserted to induce distraction. Despite the numerous advantages of this surgical technique for patients, the outcome remains unpredictable due to the lack of efficient preoperative planning tools. The surgeon's experience and the baby's age are currently relied upon to determine the osteotomy location and spring selection. Previous tools for predicting the surgical outcome of SC relied on finite element modeling (FEM), which involved computed tomography (CT) imaging and required engineering expertise and lengthy calculations. The main goal of this research is to develop a real-time prediction tool for the surgical outcome of patients, eliminating the need for CT scans to minimise radiation exposure during preoperative planning. The proposed methodology involves creating personalised synthetic skulls based on three-dimensional (3D) photographs, incorporating population average values of suture location, skull thickness, and soft tissue properties. A machine learning (ML) surrogate model is employed to achieve the desired surgical outcome. The resulting multi-output support vector regressor model achieves a R2 metric of 0.95 and MSE and MAE below 0.13. Furthermore, in the future, this model could not only simulate various surgical scenarios but also provide optimal parameters for achieving a maximum cranial index (CI). 2025-06-02T17:11:50Z 11 pages, 16 figures Itxasne Antúnez Sáenz Ane Alberdi Aramendi David Dunaway Juling Ong Lara Deliège Amparo Sáenz Anita Ahmadi Birjandi Noor UI Owase Jeelani Silvia Schievano Alessandro Borghi http://arxiv.org/abs/2506.01572v1 Advanced Nanostructured Topical Therapeutics for Psoriasis: Strategic Synthesis, Multimodal Characterization, and Preliminary Pharmacodynamic Profiling 2025-06-02T11:56:19Z Psoriasis is a long-term inflammatory skin disease that remains difficult to treat. In this study, we developed a new topical treatment by combining metal oxide nanoparticles: cerium oxide (CeO2), zinc oxide (ZnO), and silver (Ag), with natural plant extracts in a gel made from fish collagen and agar. The nanoparticles were characterized using UV-Vis spectroscopy, dynamic light scattering (DLS), Fourier-transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM), showing good stability and a uniform particle size distribution (ZnO averaged 66 nm). To enhance therapeutic potential, the gel was enriched with plant-derived antioxidants from bitter melon, ginger, and neem. This formulation was tested on an animal model of psoriasis. The treated group exhibited faster wound healing and reduced inflammation compared to both placebo and untreated groups, with statistically significant results (p < 0.01 to p < 0.001) observed from Day 3, becoming more pronounced by Day 14. These results indicate that the combination of nanoparticles with plant-based components in a topical gel may provide a promising new approach to psoriasis treatment. Further studies are recommended to evaluate long-term safety and therapeutic effectiveness. 2025-06-02T11:56:19Z 24 pages Iqra Yousaf Aqsa Yousaf http://arxiv.org/abs/2412.08499v3 Scattering polarimetry enables correlative nerve fiber imaging and multimodal analysis 2025-06-01T18:37:55Z Mapping the intricate network of nerve fibers is crucial for understanding brain function. Three-Dimensional Polarized Light Imaging (3D-PLI) and Computational Scattered Light Imaging (ComSLI) map dense nerve fibers in brain sections with micrometer resolution using visible light. 3D-PLI reconstructs 3D-fiber orientations, while ComSLI disentangles multiple directions per pixel. So far, these imaging techniques have been realized in separate setups. A combination within a single device would facilitate faster measurements, pixelwise mapping, cross-validation of fiber orientations, and leverage the advantages of each technique while mitigating their limitations. Here, we introduce the Scattering Polarimeter, a microscope that facilitates correlative large-area scans by integrating 3D-PLI and ComSLI measurements into a single system. Based on a Mueller polarimeter, it incorporates variable retarders and a large-area light source for direct and oblique illumination, enabling combined 3D-PLI and ComSLI measurements. Applied to human and vervet monkey brain sections, the Scattering Polarimeter generates results comparable to state-of-the-art 3D-PLI and ComSLI setups and creates a multimodal fiber direction map, integrating the robust fiber orientations obtained from 3D-PLI with fiber crossings from ComSLI. Furthermore, we discuss applications of the Scattering Polarimeter for unprecedented correlative and multimodal brain imaging. 2024-12-11T16:05:55Z 28 pages, 7 figures, all study data are available on https://doi.org/10.26165/JUELICH-DATA/CUXQYF Sci Rep 15, 18493 (2025) Franca auf der Heiden Markus Axer Katrin Amunts Miriam Menzel 10.1038/s41598-025-02762-w http://arxiv.org/abs/2506.01105v1 A Positivity-Preserving Finite Element Framework for Accurate Dose Computation in Proton Therapy 2025-06-01T18:07:47Z We present a stabilised finite element method for modelling proton transport in tissue, incorporating both inelastic energy loss and elastic angular scattering. A key innovation is a positivity-preserving formulation that guarantees non-negative fluence and dose, even on coarse meshes. This enables reliable computation of clinically relevant quantities for treatment planning. We derive a priori error estimates demonstrating optimal convergence rates and validate the method through numerical benchmarks. The proposed framework provides a robust, accurate and efficient tool for advancing proton beam therapy. 2025-06-01T18:07:47Z 21 pages, 11 figures Ben S. Ashby Abdalaziz Hamdan Tristan Pryer http://arxiv.org/abs/2412.03318v3 Domain-Agnostic Stroke Lesion Segmentation Using Physics-Constrained Synthetic Data 2025-06-01T00:17:19Z Segmenting stroke lesions in MRI is challenging due to diverse acquisition protocols that limit model generalisability. In this work, we introduce two physics-constrained approaches to generate synthetic quantitative MRI (qMRI) images that improve segmentation robustness across heterogeneous domains. Our first method, $\texttt{qATLAS}$, trains a neural network to estimate qMRI maps from standard MPRAGE images, enabling the simulation of varied MRI sequences with realistic tissue contrasts. The second method, $\texttt{qSynth}$, synthesises qMRI maps directly from tissue labels using label-conditioned Gaussian mixture models, ensuring physical plausibility. Extensive experiments on multiple out-of-domain datasets show that both methods outperform a baseline UNet, with $\texttt{qSynth}$ notably surpassing previous synthetic data approaches. These results highlight the promise of integrating MRI physics into synthetic data generation for robust, generalisable stroke lesion segmentation. Code is available at https://github.com/liamchalcroft/qsynth 2024-12-04T13:52:05Z Liam Chalcroft Jenny Crinion Cathy J. Price John Ashburner http://arxiv.org/abs/2506.00626v1 Helmet ultrasound for brain imaging in post-hemicraniectomy patients 2025-05-31T16:33:30Z Noninvasive imaging deep into the adult brain at submillimeter and millisecond scales remains a challenge in medical imaging. Here, we report a helmet based ultrasound brain imager built from a customized helmet, a scanned ultrasound array, and three dimensional printing for real time imaging of human brain anatomical and functional information. Through its application to post hemicraniectomy patients in a sitting position, we achieved volumetric brain tissue structural, vascular, and blood flow images at centimeter scale depths with submillimeter and millisecond spatiotemporal resolutions. We also demonstrated the system capability to track cerebral blood flow over repeated imaging sessions, including during motion prone conditions. Our brain imager circumvents the skull and bridges the gap between high resolution human brain imaging and wearable convenience. This imager may serve as a platform for further investigations into human brain dynamics in post hemicraniectomy patients and offer insights into the brain that could surpass those obtained from non human primate studies. 2025-05-31T16:33:30Z Yang Zhang Karteekeya Sastry Iyla Rossi Joshua Olick-Gibson Jonathan J. Russin Charles Y. Liu Lihong V. Wang http://arxiv.org/abs/2506.00293v1 Influence of X-ray Irradiation on the Magnetic and Structural Properties of Gadolinium Silicide Nanoparticles for Self-Regulating Hyperthermia 2025-05-30T22:53:43Z Magnetic hyperthermia treatment (MHT) utilizes heat generated from magnetic nanoparticles (MNPs) under an alternating magnetic field (AMF) for therapeutic applications. Gadolinium silicide (Gd5Si4) has emerged as a promising MHT candidate due to its self-regulating heating properties and potential biocompatibility. However, the impact of high-dose X-ray irradiation on its magnetic behavior remains uncertain. This study examines Gd5Si4 nanoparticles exposed to 36 and 72 kGy X-ray irradiation at a high-dose rate (120 Gy/min). While X-ray diffraction, scanning electron microscopy, and energy dispersive spectroscopy confirm no structural or compositional changes, transmission electron microscopy reveals localized lattice distortions, along with observable changes in magnetic properties, as evidenced in magnetization vs. temperature and hysteresis measurements. Despite this, magnetocaloric properties and specific loss power (SLP) remain unaffected. Our findings confirm the stability of Gd5Si4 under high-dose X-ray irradiation, supporting its potential for radiotherapy (RT) and magnetocaloric cooling in deep-space applications. 2025-05-30T22:53:43Z Samantha E. Smith Santiago Bermudez Pavan Chaitanya Zoe Boekelheide Jessika Rojas Marin Ravi L. Hadimani http://arxiv.org/abs/2505.24514v1 Digital twins enable full-reference quality assessment of photoacoustic image reconstructions 2025-05-30T12:25:36Z Quantitative comparison of the quality of photoacoustic image reconstruction algorithms remains a major challenge. No-reference image quality measures are often inadequate, but full-reference measures require access to an ideal reference image. While the ground truth is known in simulations, it is unknown in vivo, or in phantom studies, as the reference depends on both the phantom properties and the imaging system. We tackle this problem by using numerical digital twins of tissue-mimicking phantoms and the imaging system to perform a quantitative calibration to reduce the simulation gap. The contributions of this paper are two-fold: First, we use this digital-twin framework to compare multiple state-of-the-art reconstruction algorithms. Second, among these is a Fourier transform-based reconstruction algorithm for circular detection geometries, which we test on experimental data for the first time. Our results demonstrate the usefulness of digital phantom twins by enabling assessment of the accuracy of the numerical forward model and enabling comparison of image reconstruction schemes with full-reference image quality assessment. We show that the Fourier transform-based algorithm yields results comparable to those of iterative time reversal, but at a lower computational cost. All data and code are publicly available on Zenodo: https://doi.org/10.5281/zenodo.15388429. 2025-05-30T12:25:36Z Janek Gröhl Leonid Kunyansky Jenni Poimala Thomas R. Else Francesca Di Cecio Sarah E. Bohndiek Ben T. Cox Andreas Hauptmann http://arxiv.org/abs/2505.24349v1 The Use of Alendronate to Enhance Transcranial Transmission of Focused Ultrasound for Successful Ablations in Brain 2025-05-30T08:43:48Z Objective: The aim of this study was to evaluate the efficacy of alendronate therapy in improving bone density distribution in skull bones and corresponding ultrasound permeability in patients who had previously experienced unsuccessful transcranial MR-guided focused ultrasound (MRgFUS) ablation. The ability of alendronate treatment to modify skull bone characteristics and enhance the success rate of repeat MRgFUS procedures was assessed. Methods: Five patients with initially unsuccessful MRgFUS ablations underwent a 6-12 month regimen of alendronate to improve bone density. Repeat MRgFUS procedures were performed, and changes in skull density ratio (SDR) and peak focal temperatures were evaluated statistically using CT and MR imaging. Histograms of skull bone density were introduced and analysed as an additional metric. Results: After therapy, SDR increased in four out of five patients (from 0.378$\pm$0.037 to 0.424$\pm$0.045, p>0.05). All repeated procedures were successful. The maximum focal temperature, averaged over sonications, increased from 53.6$\pm$4.0°C to 55.7$\pm$4.1°C (p=0.018), while the maximum temperature per patient rose from 57.0$\pm$2.4°C to 60.2$\pm$1.8°C (p=0.031). Histograms of CT scans showed a reduction in low-density voxels, indicating trabecular bone densification. 3D CT scan registration revealed local density changes, defect filling, and void reduction. Conclusions: Alendronate therapy enhanced skull bone density distribution and thus ultrasound permeability, which has facilitated successful repeat MRgFUS. By visually analysing CT changes, healthcare professionals can better inform their decision-making regarding repeat surgeries. This method broadens the pool of patients with low SDR eligible for MRgFUS treatment and underscores the potential benefits of alendronate in improving treatment outcomes. 2025-05-30T08:43:48Z G. Sakharova A. Krokhmal R. Galimova A. Khatmullina D. Nabiullina I. Buzaev D. Avzaletdinova D. Chupova V. Khokhlova 10.1016/j.ultras.2025.107796 http://arxiv.org/abs/2506.03183v1 Edge Computing for Physics-Driven AI in Computational MRI: A Feasibility Study 2025-05-30T02:35:43Z Physics-driven artificial intelligence (PD-AI) reconstruction methods have emerged as the state-of-the-art for accelerating MRI scans, enabling higher spatial and temporal resolutions. However, the high resolution of these scans generates massive data volumes, leading to challenges in transmission, storage, and real-time processing. This is particularly pronounced in functional MRI, where hundreds of volumetric acquisitions further exacerbate these demands. Edge computing with FPGAs presents a promising solution for enabling PD-AI reconstruction near the MRI sensors, reducing data transfer and storage bottlenecks. However, this requires optimization of PD-AI models for hardware efficiency through quantization and bypassing traditional FFT-based approaches, which can be a limitation due to their computational demands. In this work, we propose a novel PD-AI computational MRI approach optimized for FPGA-based edge computing devices, leveraging 8-bit complex data quantization and eliminating redundant FFT/IFFT operations. Our results show that this strategy improves computational efficiency while maintaining reconstruction quality comparable to conventional PD-AI methods, and outperforms standard clinical methods. Our approach presents an opportunity for high-resolution MRI reconstruction on resource-constrained devices, highlighting its potential for real-world deployment. 2025-05-30T02:35:43Z IEEE International Conference on Future Internet of Things and Cloud (FiCloud), 2025 Yaşar Utku Alçalar Yu Cao Mehmet Akçakaya