https://arxiv.org/api/kZftkSYale6lrkfbRphtwfURXqM2026-06-27T01:19:57Z9008126015http://arxiv.org/abs/2506.08654v1A Privacy-Preserving Federated Learning Framework for Generalizable CBCT to Synthetic CT Translation in Head and Neck2025-06-10T10:10:56ZShortened Abstract
Cone-beam computed tomography (CBCT) has become a widely adopted modality for image-guided radiotherapy (IGRT). However, CBCT suffers from increased noise, limited soft-tissue contrast, and artifacts, resulting in unreliable Hounsfield unit values and hindering direct dose calculation. Synthetic CT (sCT) generation from CBCT addresses these issues, especially using deep learning (DL) methods. Existing approaches are limited by institutional heterogeneity, scanner-dependent variations, and data privacy regulations that prevent multi-center data sharing.
To overcome these challenges, we propose a cross-silo horizontal federated learning (FL) approach for CBCT-to-sCT synthesis in the head and neck region, extending our FedSynthCT framework. A conditional generative adversarial network was collaboratively trained on data from three European medical centers in the public SynthRAD2025 challenge dataset.
The federated model demonstrated effective generalization across centers, with mean absolute error (MAE) ranging from $64.38\pm13.63$ to $85.90\pm7.10$ HU, structural similarity index (SSIM) from $0.882\pm0.022$ to $0.922\pm0.039$, and peak signal-to-noise ratio (PSNR) from $32.86\pm0.94$ to $34.91\pm1.04$ dB. Notably, on an external validation dataset of 60 patients, comparable performance was achieved (MAE: $75.22\pm11.81$ HU, SSIM: $0.904\pm0.034$, PSNR: $33.52\pm2.06$ dB) without additional training, confirming robust generalization despite protocol, scanner differences and registration errors.
These findings demonstrate the technical feasibility of FL for CBCT-to-sCT synthesis while preserving data privacy and offer a collaborative solution for developing generalizable models across institutions without centralized data sharing or site-specific fine-tuning.2025-06-10T10:10:56ZFrontiers in Digital Health, 8:1812254, June 2026Ciro Benito RaggioPaolo ZaffinoMaria Francesca Spadea10.3389/fdgth.2026.1812254http://arxiv.org/abs/2501.07579v4Correlation Between DNA Double-Strand Break Distribution in 3D Genome and Radiation-Induced Cell Death2025-06-10T00:37:45ZThe target theory is the most classical hypothesis explaining radiation-induced cell death, the physical or biological nature of the "target" remains ambiguous. This study hypothesizes that the distribution of DNA double-strand breaks (DSBs) within the 3D genome is a pivotal factor affecting the probability of radiation-induced cell death. We propose that clustered DSBs in DNA segments with high interaction frequencies are more susceptible to leading to cell death than isolated DSBs. Topologically associating domains (TAD) can be regarded as the reference unit for evaluating the impact of DSB clustering in the 3D genome. To quantify this correlation between the DSB distribution in 3D genome and radiation-induced effect, we developed a simplified model considering the DSB distribution across TADs. Utilizing track-structure Monte Carlo codes to simulate the electron and carbon ion irradiation, we calculated the incidence of each case across a variety of radiation doses and LETs. Our simulation results indicate that DSBs in TADs with frequent interactions (case 3) are significantly more likely to induce cell death than clustered DSBs within a single TAD (case 2). Moreover, case 2 is significantly more likely to induce cell death than isolated DSBs (case 1). The curves of the incidence of case 2 and case 3 versus LETs have a similar shape to the radiation quality factor used in radiation protection. This indicates that these two cases are also associated with the stochastic effects induced by high LET irradiation. Our study underscores the significance of the 3D genome structure in the fundamental mechanisms of radiobiological effects. The hypothesis in our research offers novel perspectives on the mechanisms that regulate radiobiological effects. Moreover, it serves as a valuable reference for establishing mechanistic models that can predict cell survival under different doses and LETs.2024-12-27T12:17:27Z19 pages, 6 figures, 1 supplementary documentRadiation Research. 2025, 203(6): 421-432Ankang HuWanyi ZhouXiyu LuoRui QiuJunli Li10.1667/RADE-24-00277.1http://arxiv.org/abs/2406.16267v2Geodesic-based Predictive Shape Modeling of the Right Ventricle in Patients with Hypoplastic Left Heart Syndrome2025-06-09T16:51:54ZHypoplastic left heart syndrome (HLHS) is characterized by severe underdevelopment of left ventricle requiring staged surgical reconstruction (stages) to allow the right ventricle (RV) alone to support the circulation. In this setting changes in RV size and shape over time reflect adaptations to single-ventricle physiology, dysfunction of the associated tricuspid valve (TV), and are associated with circulatory failure. As such, an accurate prediction of the RV shape of a patient would inform understanding of both RV and TV failure, as well as clinical prognosis and associated decision making. We present a geodesic-based predictive shape modeling framework applied a cohort of RVs obtained from 15 HLHS patients at three individual time points. Reasonable predictions on stage 1 RV shapes can generated using pre-stage 1 RV shapes and two predictors from prior clinical and demographic measures. Our results demonstrate the future potential for a data-driven method to predict how the morphology of the RV of an individual patient will change in size and shape over time. Future studies will seek to expand the training sample size and integrate more comprehensive demographic and morphological data into the proposed predictive model.2024-06-24T02:21:04Z14 pages, 3 figures, 1 tableYe HanJames FishbaughJared VicorySilvani AminMatthew DaemerHannah E. DeweyYan WangAnalise M. SulenticAlana CianciulliAndras LassoMatthew A. JolleyBeatriz Paniaguahttp://arxiv.org/abs/2506.19855v1Neural networks for the prediction of peel force for skin adhesive interface using FEM simulation2025-06-09T12:22:00ZStudying the peeling behaviour of adhesives on skin is vital for advancing biomedical applications such as medical adhesives and transdermal patches. Traditional methods like experimental testing and finite element method (FEM), though considered gold standards, are resource-intensive, computationally expensive and time-consuming, particularly when analysing a wide material parameter space. In this study, we present a neural network-based approach to predict the minimum peel force (F_min) required for adhesive detachment from skin tissue, limiting the need for repeated FEM simulations and significantly reducing the computational cost. Leveraging a dataset generated from FEM simulations of 90 degree peel test with varying adhesive and fracture mechanics parameters, our neural network model achieved high accuracy, validated through rigorous 5-fold cross-validation. The final architecture was able to predict a wide variety of skin-adhesive peeling behaviour, exhibiting a mean squared error (MSE) of 3.66*10^-7 and a R^2 score of 0.94 on test set, demonstrating robust performance. This work introduces a reliable, computationally efficient method for predicting adhesive behaviour, significantly reducing simulation time while maintaining accuracy. This integration of machine learning with high-fidelity biomechanical simulations enables efficient design and optimization of skin-adhesive systems, providing a scalable framework for future research in computational dermato-mechanics and bio-adhesive material design.2025-06-09T12:22:00ZAshish MasarkarRakesh GuptaNaga Neehar DingariBeena Raihttp://arxiv.org/abs/2309.06067v8Efficient MRI Parallel Imaging Reconstruction by K-Space Rendering via Generalized Implicit Neural Representation2025-06-09T05:59:27ZHigh-resolution magnetic resonance imaging (MRI) is essential in clinical diagnosis. However, its long acquisition time remains a critical issue. Parallel imaging (PI) is a common approach to reduce acquisition time by periodically skipping specific k-space lines and reconstructing images from undersampled data. This study presents a generalized implicit neural representation (INR)-based framework for MRI PI reconstruction, addressing limitations commonly encountered in conventional methods, such as subject-specific or undersampling scale-specific requirements and long reconstruction time. The proposed method overcomes these limitations by leveraging prior knowledge of voxel-specific features and integrating a novel scale-embedded encoder module. This encoder generates scale-independent voxel-specific features from undersampled images, enabling robust reconstruction across various undersampling scales without requiring retraining for each specific scale or subject. The INR model treats MR signal intensities and phase values as continuous functions of spatial coordinates and prior knowledge to render fully sampled k-space, efficiently reconstructing high-quality MR images from undersampled data. Extensive experiments on publicly available MRI datasets demonstrate the superior performance of the proposed method in reconstructing images at multiple acceleration factors (4x, 5x, and 6x), achieving higher evaluation metrics and visual fidelity compared to state-of-the-art methods. In terms of efficiency, this INR-based approach exhibits notable advantages, including reduced floating point operations and GPU usage, allowing for accelerated processing times while maintaining high reconstruction quality. The generalized design of the model significantly reduces computational resources and time consumption, making it more suitable for real-time clinical applications.2023-09-12T09:07:03ZHao LiYusheng ZhouJianan LiuXiling LiuTao HuangZhihan LyuWeidong CaiWei Chenhttp://arxiv.org/abs/2506.07225v1Active Lubrication of Transluminal Medical Instruments2025-06-08T17:18:29ZTransluminal minimally invasive surgery uses natural orifices and small incisions to access internal anatomical structures, promoting quicker recovery and reduced morbidity. However, navigating instruments--catheters and endoscopes--through anatomical pathways creates frictional interactions with luminal walls, risking complications such as perforation, poor haptic feedback, and instrument buckling. In this paper, we present a new approach to actively lubricate transluminal instruments and dynamically reduce friction with surrounding tissues. This approach employs ultrasonic vibrations, at the instrument surface, to generate a pressurized fluid layer at the contact interface, lubricating the interface and thereby reducing friction. We implemented this approach in a prototype catheter, which we validated under dry and liquid-lubricated conditions, across rigid and soft interfaces, and along varied anatomical curvatures. In a cardiac catheter use case, active lubrication reduced friction by up to 42% on ex-vivo porcine aorta tissue and 82% on rigid substrates, denoting its potential performance on healthy and calcified tissue, respectively. Thermal imaging confirmed that temperature at the tissue-catheter interface remained within safe limits. Additionally, the system effectively prevented buckling during catheter insertion experiment, further showcasing its potential. By minimizing injury risk and enhancing procedural stability, active lubrication can drastically enhance the safety and efficacy of transluminal interventions.2025-06-08T17:18:29ZMostafa A. AtallaJelte NieuwenhuisAlan MartinXuan WangAhranee CandenMatt J. CarréRoger LewisAimée SakesMichaël Wiertlewskihttp://arxiv.org/abs/2502.04039v2A Cloud-native Agile approach to cyber platform prototyping and integration for astronomy: the ENGAGE SKA case2025-06-06T22:56:44ZThe Square Kilometre Array (SKA) Observatory is gearing up the formal construction of its two radio interferometers in Australia and South Africa after the end of design and pre-construction phases. Agile methodologies, the Cloud native Computing technologies and the DevOps software ideas are influencing the design of compute infrastructures that will be key to reduce the operational costs of SKA while improving the control and monitoring of the SKA antennas and ancillary systems, Correlators, HPC facilities or related data centre tiered systems. These tools will likely include advanced power metering technologies and efficient distribution automation and Network Operation Centres (NOC). SKA will become the world's largest radio telescope and is expected to achieve its first science by 2026. To cope with this dimension and complexity, a key part of this distributed Observatory is the overall software control and monitoring system embodied in the Observatory Management and Control (OMC) and the Services Teams that requires specialized Agile Teams to assist in software and cyber infrastructure building using an Agile development environment that includes test automation, Continuous Integration, and Continuous Deployment. To manage such a large and distributed machine, the Agile approach was adopted for the core software package of the SKA Telescope aimed at scheduling observations, controlling their execution, monitoring the telescope status and ensuring scalability and reliability. Here, we report on the ENGAGE SKA ciberinfrastructure prototyping support to the SKA Agile Software Development Life Cycle (SDLC).2025-02-06T13:01:27Z21 pages, 6 figures. Revised version - Technical Report article to the The Journal of Instrumentation (JINST)Journal of Instrumentation, Volume 20, pag. T07004, July 2025Domingos BarbosaDiogo RegateiroJoão Paulo BarracaDzianis BartashevichMarco BartoliniMatteo di CarloPiers HardingDalmiro MaiaBruno MorgadoDomingos NunesBruno RibeiroBruno CoelhoValério RibeiroAllan K. de AlmeidaTimothée VaillantUğur Yilmaz10.1088/1748-0221/20/07/T07004http://arxiv.org/abs/2410.24120v2Impact of normal lung volume choices on radiation pneumonitis risk prediction in locally advanced NSCLC radiotherapy2025-06-06T18:50:18ZThis study is to evaluate the impact of lung volume choices on predicting radiation pneumonitis (RP) risk in patients with locally advanced NSCLC undergoing radiotherapy. Dosimetric variables V20, V5, and mean lung dose (MLD) were extracted from the treatment plans of 442 patients enrolled in the NRG Oncology RTOG 0617 trial. Three lung volumes were defined: total lung excluding gross-tumor-target (TL-GTV), total lung excluding clinical-target-volume (TL-CTV), and total lung excluding planning-target-volume (TL-PTV). Patients were grouped as no-RP2 (N = 377, grade <= 1 RP) and RP2 (N = 65, grade >= 2 RP). Statistical analyses were performed to assess the effect on lung volume definition on RP2 prediction. Three supervised machine learning (ML) models: logistic regression (LR), k-Nearest Neighbor (kNN), and eXtreme Gradient Boosting (XGB), were used to evaluate predictive performance. Model performance was quantified using the area under the receiver operating characteristic curve (AUC), and statistical significance was tested via a bootstrap analysis. Shapley Additive Explanations (SHAP) were applied to interpret feature contributions to model predictions. Statistical analyses showed that V20 and MLD were significantly associated with RP2, while differences among volume definitions were not statistically significant. Both kNN and XGB classifiers consistently yielded higher AUC values for the TL-PTV definition compared to the other definitions, a finding supported by bootstrap analysis. SHAP analysis further indicated that V20 and MLD were the most influential predictors of RP2. Both statistical analysis and SHAP confirmed that V20 and MLD were associated with RP2. The ML models indicated that defining normal lung volume as total lung excluding PTV yielded the highest predictive performance for RP2 risk. Further validation using external datasets is warranted to confirm these findings.2024-10-31T16:48:51Z16 page, 4 figures and 1 tableAdv Radiat Oncol. 2025 Jul 3;10(8):101825Alyssa GadsbyTian LiuRobert SamsteinJiahan ZhangYang LeiKenneth E. RosenzweigMing Chao10.1016/j.adro.2025.101825http://arxiv.org/abs/2506.05118v1A Gaussian process approach for rapid evaluation of skin tension2025-06-05T15:03:13ZSkin tension plays a pivotal role in clinical settings, it affects scarring, wound healing and skin necrosis. Despite its importance, there is no widely accepted method for assessing in vivo skin tension or its natural pre-stretch. This study aims to utilise modern machine learning (ML) methods to develop a model that uses non-invasive measurements of surface wave speed to predict clinically useful skin properties such as stress and natural pre-stretch. A large dataset consisting of simulated wave propagation experiments was created using a simplified two-dimensional finite element (FE) model. Using this dataset, a sensitivity analysis was performed, highlighting the effect of the material parameters and material model on the Rayleigh and supersonic shear wave speeds. Then, a Gaussian process regression model was trained to solve the ill-posed inverse problem of predicting stress and pre-stretch of skin using measurements of surface wave speed. This model had good predictive performance (R2 = 0.9570) and it was possible to interpolate simplified parametric equations to calculate the stress and pre-stretch. To demonstrate that wave speed measurements could be obtained cheaply and easily, a simple experiment was devised to obtain wave speed measurements from synthetic skin at different values of pre-stretch. These experimental wave speeds agree well with the FE simulations and a model trained solely on the FE data provided accurate predictions of synthetic skin stiffness. Both the simulated and experimental results provide further evidence that elastic wave measurements coupled with ML models are a viable non-invasive method to determine in vivo skin tension.2025-06-05T15:03:13ZActa Biomaterialia. Vol.182 (2024) 54-66Matt NagleHannah Conroy BroderickChristelle VedelMichel DestradeMichael FopAisling Ni Annaidh10.1016/j.actbio.2024.05.025http://arxiv.org/abs/2408.02541v2Modelling power-law ultrasound absorption using a time-fractional, static memory, Fourier pseudo-spectral method2025-06-05T14:03:13ZWe describe and implement a numerical method for modelling the frequency-dependent power-law absorption of ultrasound in tissue, as governed by the first order linear wave equations with a loss taking the form of a fractional time derivative. The (Caputo) fractional time derivative requires the full problem history which is contained within an iterative procedure. The resulting numerical method requires a fixed (static) memory cost irrespective of the number of time steps. The spatial domain is treated by the Fourier spectral method. Numerically comparisons are made against a model for the same power-law absorption with loss described by the fractional-Laplacian operator. One advantage of the fractional time derivative over the fractional-Laplacian operator is the local treatment of the power-law, allowing for a spatially varying frequency power-law.2024-08-05T15:15:33Zvol. 157, issue 3, pp. 1761-1771 (2025)Matthew. J. KingTimon. S. GutlebB. E. TreebyB. T. Cox10.1121/10.0035937http://arxiv.org/abs/2506.04976v1Fast PET Reconstruction with Variance Reduction and Prior-Aware Preconditioning2025-06-05T12:47:47ZWe investigate subset-based optimization methods for positron emission tomography (PET) image reconstruction incorporating a regularizing prior. PET reconstruction methods that use a prior, such as the relative difference prior (RDP), are of particular relevance, as they are widely used in clinical practice and have been shown to outperform conventional early-stopped and post-smoothed ordered subsets expectation maximization (OSEM).
Our study evaluates these methods on both simulated data and real brain PET scans from the 2024 PET Rapid Image Reconstruction Challenge (PETRIC), where the main objective was to achieve RDP-regularized reconstructions as fast as possible, making it an ideal benchmark. Our key finding is that incorporating the effect of the prior into the preconditioner is crucial for ensuring fast and stable convergence.
In extensive simulation experiments, we compare several stochastic algorithms -- including Stochastic Gradient Descent (SGD), Stochastic Averaged Gradient Amelioré (SAGA), and Stochastic Variance Reduced Gradient (SVRG) -- under various algorithmic design choices and evaluate their performance for varying count levels and regularization strengths. The results show that SVRG and SAGA outperformed SGD, with SVRG demonstrating a slight overall advantage. The insights gained from these simulations directly contributed to the design of our submitted algorithms, which formed the basis of the winning contribution to the PETRIC 2024 challenge.2025-06-05T12:47:47Z20 pages, 8 figuresMatthias J. EhrhardtZeljko KeretaGeorg Schrammhttp://arxiv.org/abs/2410.02292v2Two-dimensional materials as ideal substrates for molecular quantum emitters2025-06-05T12:33:54ZThe generation and manipulation of non-classical states of light is central to quantum technologies. Color centers in insulators have been extensively studied for single-photon generation, but organic molecules immobilized on substrates have gained attention due to their superior scalability, large oscillator strengths, and tunable emission frequency. Here, we use first-principles calculations to investigate the photoemission from organic molecules adsorbed on 2D materials. Focusing on terrylene on hexagonal boron nitride (hBN), we obtain zero phonon line (ZPL) energies and emission lineshapes in excellent agreement with experiments. Notably, antisite defects in hBN can immobilize the molecule without influencing its key emission features. We further show that the main effect of the 2D substrate is to introduce sharp sidebands near the ZPL as a fingerprint of hindered rotational, translational, or bending modes of the molecule. Our findings provide insight into how substrate interactions shape the optical properties of molecular systems for quantum applications.2024-10-03T08:22:57ZHaiyuan WangNicolas StengerPeder LyngbyMikael KuismaJakob SchiøtzKristian Sommer Thygesenhttp://arxiv.org/abs/2501.07973v2An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors2025-06-05T11:47:59ZMeasuring the blood pressure waveform is becoming a more frequently studied area. The development of sensor technologies opens many new ways to be able to measure high-quality signals. The development of such an aim-specific sensor can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this paper, we present an open source blood pressure waveform simulator with an open source Python validation package to reduce development costs for early-stage sensor development and research. The simulator mainly consists of 3D printed parts which technology has become a widely available and cheap solution. The core part of the simulator is a 3D printed cam that can be generated based on real blood pressure waveforms. The validation framework can create a detailed comparison between the signal waveform used to design the cam and the measured time series from the sensor being validated. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform consistently and accurately. To validate this solution, a 3D force sensor was used, which was proven earlier to be able to measure high-quality blood pressure waveforms on the radial artery at the wrist. The results showed high similarity between the measured and the nominal waveforms, meaning that comparing the normalized signals, the RMSE value ranged from $0.0276 \pm 0.0047$ to $0.0212 \pm 0.0023$, and the Pearson correlation ranged from $0.9933 \pm 0.0027$ to $0.9978 \pm 0.0005$. Our validation framework is available at https://github.com/repat8/cam-bpw-sim. Our hardware framework, which allows reproduction of the presented solution, is available at https://github.com/repat8/cam-bpw-sim-hardware. The entire design is an open source project and was developed using free software.2025-01-14T09:46:18Z8 pages, 5 figures. For associated repositories see https://github.com/repat8/cam-bpw-sim-hardware and https://github.com/repat8/cam-bpw-simAttila RépaiJedlik Innovation Ltd., Budapest, HungarySándor FöldiFaculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, HungaryPéter SótonyiFaculty of Medicine, Department of Vascular and Endovascular Surgery, Semmelweis University, Budapest, HungaryGyörgy CsereyFaculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungaryhttp://arxiv.org/abs/2506.04473v1Diffusion Tensor MRI and Spherical-Deconvolution-Based Tractography on an Ultra-Low Field Portable MRI System2025-06-04T21:43:56ZUltra-low-field (ULF) MRI is emerging as an alternative modality to high-field (HF) MRI due to its lower cost, minimal siting requirements, portability, and enhanced accessibility factors that enable large-scale deployment. Although ULF-MRI exhibits lower signal-to-noise ratio (SNR), advanced imaging and data-driven denoising methods enabled by high-performance computing have made contrasts like diffusion-weighted imaging (DWI) feasible at ULF. This study investigates the potential and limitations of ULF tractography, using data acquired on a 0.064 T commercially available mobile point-of-care MRI scanner. The results demonstrate that most major white matter bundles can be successfully retrieved in healthy adult brains within clinically tolerable scan times. This study also examines the recovery of diffusion tensor imaging (DTI)-derived scalar maps, including fractional anisotropy and mean diffusivity. Strong correspondence is observed between scalar maps obtained with ULF-MRI and those acquired at high field strengths. Furthermore, fibre orientation distribution functions reconstructed from ULF data show good agreement with high-field references, supporting the feasibility of using ULF-MRI for reliable tractography. These findings open new opportunities to use ULF-MRI in studies of brain health, development, and disease progression particularly in populations traditionally underserved due to geographic or economic constraints. The results show that robust assessments of white matter microstructure can be achieved with ULF-MRI, effectively democratising microstructural MRI and extending advanced imaging capabilities to a broader range of research and clinical settings where resources are typically limited.2025-06-04T21:43:56ZJames GholamPhil SchmidJoshua AmetepeAlix PlumleyLeandro BeltrachiniFrancesco PadormoRui TeixeiraRafael OHalloranKaloian PetkovKlaus EngelSteven CR WilliamsSean DeoniMara CercignaniDerek K Joneshttp://arxiv.org/abs/2506.04467v1Diffusion Transformer-based Universal Dose Denoising for Pencil Beam Scanning Proton Therapy2025-06-04T21:37:15ZPurpose: Intensity-modulated proton therapy (IMPT) offers precise tumor coverage while sparing organs at risk (OARs) in head and neck (H&N) cancer. However, its sensitivity to anatomical changes requires frequent adaptation through online adaptive radiation therapy (oART), which depends on fast, accurate dose calculation via Monte Carlo (MC) simulations. Reducing particle count accelerates MC but degrades accuracy. To address this, denoising low-statistics MC dose maps is proposed to enable fast, high-quality dose generation.
Methods: We developed a diffusion transformer-based denoising framework. IMPT plans and 3D CT images from 80 H&N patients were used to generate noisy and high-statistics dose maps using MCsquare (1 min and 10 min per plan, respectively). Data were standardized into uniform chunks with zero-padding, normalized, and transformed into quasi-Gaussian distributions. Testing was done on 10 H&N, 10 lung, 10 breast, and 10 prostate cancer cases, preprocessed identically. The model was trained with noisy dose maps and CT images as input and high-statistics dose maps as ground truth, using a combined loss of mean square error (MSE), residual loss, and regional MAE (focusing on top/bottom 10% dose voxels). Performance was assessed via MAE, 3D Gamma passing rate, and DVH indices.
Results: The model achieved MAEs of 0.195 (H&N), 0.120 (lung), 0.172 (breast), and 0.376 Gy[RBE] (prostate). 3D Gamma passing rates exceeded 92% (3%/2mm) across all sites. DVH indices for clinical target volumes (CTVs) and OARs closely matched the ground truth.
Conclusion: A diffusion transformer-based denoising framework was developed and, though trained only on H&N data, generalizes well across multiple disease sites.2025-06-04T21:37:15ZYuzhen DingJason HolmesHongying FengMartin BuesLisa A. McGeeJean-Claude M. RwigemaNathan Y. YuTerence S. SioSameer R. KeoleWilliam W. WongSteven E. SchildJonathan B. AshmanSujay A. VoraDaniel J. MaSamir H. PatelWei Liu