https://arxiv.org/api/dPipqD4wzCpXqYuAlj8yTWEaujg2026-06-27T00:14:10Z9008124515http://arxiv.org/abs/2506.14995v1Improved Image Reconstruction and Diffusion Parameter Estimation Using a Temporal Convolutional Network Model of Gradient Trajectory Errors2025-06-17T22:01:06ZSummary: Errors in gradient trajectories introduce significant artifacts and distortions in magnetic resonance images, particularly in non-Cartesian imaging sequences, where imperfect gradient waveforms can greatly reduce image quality. Purpose: Our objective is to develop a general, nonlinear gradient system model that can accurately predict gradient distortions using convolutional networks. Methods: A set of training gradient waveforms were measured on a small animal imaging system, and used to train a temporal convolutional network to predict the gradient waveforms produced by the imaging system. Results: The trained network was able to accurately predict nonlinear distortions produced by the gradient system. Network prediction of gradient waveforms was incorporated into the image reconstruction pipeline and provided improvements in image quality and diffusion parameter mapping compared to both the nominal gradient waveform and the gradient impulse response function. Conclusion: Temporal convolutional networks can more accurately model gradient system behavior than existing linear methods and may be used to retrospectively correct gradient errors.2025-06-17T22:01:06ZJonathan B. MartinHannah E. AldersonJohn C. GoreMark D. DoesKevin D. Harkinshttp://arxiv.org/abs/2412.19552v2Contrast-Optimized Basis Functions for Self-Navigated Motion Correction in Quantitative MRI2025-06-17T14:44:01ZPurpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions in a singular value decomposition (SVD) subspace. However, the SVD promotes high signal intensity in all tissues, which limits the contrast between tissue types and ultimately reduces the accuracy of registration. The purpose of this paper is to rotate the subspace for maximum contrast between two types of tissue and improve the accuracy of motion estimates.
Methods: A subspace is derived that promotes contrasts between brain parenchyma and CSF, achieved through the generalized eigendecomposition of mean autocorrelation matrices, followed by a Gram-Schmidt process to maintain orthogonality. We tested our motion correction method on 85 scans with varying motion levels, acquired with a 3D hybrid-state sequence optimized for quantitative magnetization transfer imaging.
Results: A comparative analysis shows that the contrast-optimized basis significantly improve the parenchyma-CSF contrast, leading to smoother motion estimates and reduced artifacts in the quantitative maps.
Conclusion: The proposed contrast-optimized subspace improves the accuracy of the motion estimation.2024-12-27T09:49:35ZElisa MarchettoSebastian FlassbeckAndrew MaoJakob Assländerhttp://arxiv.org/abs/2506.13460v2First Positronium Lifetime Imaging with Scandium-44 on a Long Axial Field-of-view PET/CT2025-06-17T14:11:47ZPurpose: 44Sc has been successfully produced, synthesized, labeled and first-in-human studies were conducted some years ago. The decay properties of 44Sc, together with being close to a clinical implementation, make it an ideal candidate for in vivo positronium lifetime measurements. In this study, we investigate the count statistics for ortho-positronium (oPs) measurements with 44Sc.
Method: A NEMA image quality phantom was filled with 41.7 MBq of 44Sc dissolved in water and scanned on a commercial long-axial field-of-view PET/CT. Three-photon events were identified using a prototype feature of the scanner and dedicated software. The lifetime of oPs was determined in the phantom spheres and in 4x4x4 mm^3 voxels.
Results: All measured oPs lifetimes are compatible, within the uncertainties, with the literature values for water. The oPs lifetime is 2.65+-0.50, 1.39+-0.20 and 1.76+-0.18 ns in the three smallest spheres of the phantom and 1.79+-0.57 ns for a single voxel in the central region of the largest sphere. The relative standard deviation in the background regions of the time difference distributions, i.e., for time differences smaller than -2.7 ns, is above 20% - even for voxels inside the phantom spheres.
Conclusions: Despite the favorable physical properties of 44Sc, the count statistics of three-photon events remains a challenge. The high prompt-photon energy causes a significant amount of random three-photon coincidences with the given methodology and, therefore, increases the statistical uncertainties on the measured oPs lifetime.2025-06-16T13:15:35ZLorenzo MercolliWilliam M. SteinbergerPascal V. GrundlerAnzhelika MoiseevaSaverio BracciniMaurizio ContiPaweł MoskalNarendra RathodAxel RomingerHasan SariRoger SchibliRobert SeifertKuangyu ShiEwa Ł. StępieńNicholas P. van der Meulenhttp://arxiv.org/abs/2506.13959v1Harnessing the "Reactive Falling Effect" for rehabilitation and performance boosting2025-06-16T20:03:54ZWe present Logic Workout, a novel training method based on radical dynamic instability combining rolling, deformation and spring instability on small fitballs. By exploiting the "reactive falling effect", it re-engages innate balance mechanisms and forces real-time motor corrections, leading to better joint control, coordination, and movement precision. Preliminary results from a cohort of 18 participants show complete resolution of chronic pain, enhanced functional mobility, and surprising improvements in strength and performance -- challenging the belief that instability training impairs power output. We hypothesise that, by harnessing maximal instability, Logic Workout activates deep neuromuscular pathways and improve rehabilitation outcomes, training efficiency, and athletic performance.2025-06-16T20:03:54Z8 pagesPaul-Emmanuel SornetteDidier Sornettehttp://arxiv.org/abs/2506.13447v1Towards real-time additive-free dopamine detection at $10^{-8}$ mM with hardware accelerated platform integrated on camera2025-06-16T13:04:15ZTracing physiological neurotransmitters such as dopamine (DA) with detection limits down to $\mathrm{1\times10^{-8}}$ mM is a critical goal in neuroscience for studying brain functions and progressing the understanding of cerebral disease. Addressing this problem requires enhancing the current state-of-the-art additive-free electrochemical workstation methods by over two orders of magnitude. In this work, we implement an ultra-sensitive, additive-free platform exploiting suitably engineered light-scattering membranes and optical accelerators integrated into commercial vision cameras, reporting real-time detection of DA in uric and ascorbic acid below the concentration of $\mathrm{10^{-8}}$ mM. These performances improve the current best technology by over two orders of magnitude in resolution while providing continuous, real-time detection at video rates. This technology also upgrades the bulk form factor of an electrochemical workstation with an imaging camera's compact and portable footprint. The optical accelerator implemented in this work is universal and trainable to detect a wide range of biological analytes. This technology's wide adoption could help enable early disease detection and personalized treatment adjustments while improving the management of neurological, mental, and immune-related conditions.2025-06-16T13:04:15ZNing LiQizhou WangZhao HeArturo Burguete-LopezFei XiangAndrea Fratalocchihttp://arxiv.org/abs/2404.18458v2A robust and scalable framework for hallucination detection in virtual tissue staining and digital pathology2025-06-16T08:33:51ZHistopathological staining of human tissue is essential for disease diagnosis. Recent advances in virtual tissue staining technologies using artificial intelligence (AI) alleviate some of the costly and tedious steps involved in traditional histochemical staining processes, permitting multiplexed staining and tissue preservation. However, potential hallucinations and artifacts in these virtually stained tissue images pose concerns, especially for the clinical uses of these approaches. Quality assessment of histology images by experts can be subjective. Here, we present an autonomous quality and hallucination assessment method, AQuA, for virtual tissue staining and digital pathology. AQuA autonomously achieves 99.8% accuracy when detecting acceptable and unacceptable virtually stained tissue images without access to histochemically stained ground truth, and presents an agreement of 98.5% with the manual assessments made by board-certified pathologists, including identifying realistic-looking images that could mislead diagnosticians. We demonstrate the wide adaptability of AQuA across various virtually and histochemically stained human tissue images. This framework enhances the reliability of virtual tissue staining and provides autonomous quality assurance for image generation and transformation tasks in digital pathology and computational imaging.2024-04-29T06:32:28Z45 Pages, 22 Figures, 2 TablesNature Biomedical Engineering (2025)Luzhe HuangYuzhu LiNir PillarTal Keidar HaranWilliam Dean WallaceAydogan Ozcan10.1038/s41551-025-01421-9http://arxiv.org/abs/2506.13208v1Fractional order derivative approach of viscoelastic behavior of tropical wood2025-06-16T08:12:09ZFor some time now, wood has offered itself as an alternative to other modern construction materials, and has become the material of choice for structures, mainly because of its renewable nature, durability and ease of shaping. However, once in service, even at room temperature and under low stresses, it deforms and faces the problems of creep and recovery. The aims of this work is to model and predict the viscoelastic deformations of tropical wood by a rheological approach based on fractional calculus theory. Frist, Zener fractional model was used to elucidate these phenomena. The simulations show that the proposed model fit the creep experimental data with an average reliability of 96% and the recovery process with a reliability of 99%. The optimal parameters of this model, determined through an optimization algorithm, exhibit sensitivity to the stress level. To address this issue and enhance the predictive capability of the model, nonlinearities are incorporated into the fractional model, resulting in modified versions that remain applicable across various stress levels.2025-06-16T08:12:09ZWorld Conference on Timber Engineering, Jun 2025, Brisbane, Australia. pp.5437 - 5443Loic Chrislin NguedjioIPRostand Moutou PittiCENAREST, IPBenoit BlaysatIPPierre Kisito TallaIPNicolas SauvatIPJoseph GrilIPhttp://arxiv.org/abs/2506.12228v1Accuracy and Precision of Random Walk with Barrier Model Fitting: Simulations and Applications in Head and Neck Cancers2025-06-13T21:11:22ZPromising results have been reported in quantifying microstructural parameters (free diffusivity, cell size, and membrane permeability) in head and neck cancers (HNCs) using time-dependent diffusion MRI fitted to Random Walk with Barrier Model (RWBM). However, model fitting remains challenging due to limited number of measurements, low signal-to-noise ratio and complex nonlinear biophysical model. In this work, we comprehensively investigated and elucidated the dependence of RWBM fitting performance on tissue property, data acquisition and processing, and provided insights on improving data acquisition and model fitting. We numerically evaluated the accuracy and precision of RWBM fitting using non-linear least squares as a function of model parameters, noise levels, and maximum effective diffusion times over a wide range of microstructural parameter values. We then elucidated these results by examining the model's degeneracy and fitting landscape. In vivo fitting results on patients with HNCs were analyzed and were interpreted using the numerical results. We observed that free diffusivity estimates were accurate and precise over a wide range of microstructural parameters, whereas the accuracy and precision of surface-to-volume ratio and membrane permeability depended on the values of the parameters. In addition, a maximum effective diffusion time of 200 ms provided the lowest bias and variance in membrane permeability estimations. By fitting to the short-time limit expression, we observed that the variance of parameter estimation was reduced, and that a more accurate and precise estimation of membrane permeability was achieved. In vivo fitting results were consistent with the numerical findings. In conclusion, this work provides a comprehensive analysis of RWBM fitting in clinical settings and has the potential to guide further optimizations of data acquisition and model fitting methods.2025-06-13T21:11:22ZJiaren ZouYue Caohttp://arxiv.org/abs/2506.11957v1Automated Treatment Planning for Interstitial HDR Brachytherapy for Locally Advanced Cervical Cancer using Deep Reinforcement Learning2025-06-13T17:07:30ZHigh-dose-rate (HDR) brachytherapy plays a critical role in the treatment of locally advanced cervical cancer but remains highly dependent on manual treatment planning expertise. The objective of this study is to develop a fully automated HDR brachytherapy planning framework that integrates reinforcement learning (RL) and dose-based optimization to generate clinically acceptable treatment plans with improved consistency and efficiency. We propose a hierarchical two-stage autoplanning framework. In the first stage, a deep Q-network (DQN)-based RL agent iteratively selects treatment planning parameters (TPPs), which control the trade-offs between target coverage and organ-at-risk (OAR) sparing. The agent's state representation includes both dose-volume histogram (DVH) metrics and current TPP values, while its reward function incorporates clinical dose objectives and safety constraints, including D90, V150, V200 for targets, and D2cc for all relevant OARs (bladder, rectum, sigmoid, small bowel, and large bowel). In the second stage, a customized Adam-based optimizer computes the corresponding dwell time distribution for the selected TPPs using a clinically informed loss function. The framework was evaluated on a cohort of patients with complex applicator geometries. The proposed framework successfully learned clinically meaningful TPP adjustments across diverse patient anatomies. For the unseen test patients, the RL-based automated planning method achieved an average score of 93.89%, outperforming the clinical plans which averaged 91.86%. These findings are notable given that score improvements were achieved while maintaining full target coverage and reducing CTV hot spots in most cases.2025-06-13T17:07:30Z12 pages, 2 figures, 3 tablesMohammadamin MoradiRunyu JiangYingzi LiuMalvern MadondoTianming WuJames J. SohnXiaofeng YangYasmin HasanZhen Tianhttp://arxiv.org/abs/2506.11771v1Fast MRI of bones in the knee -- An AI-driven reconstruction approach for adiabatic inversion recovery prepared ultra-short echo time sequences2025-06-13T13:28:53ZPurpose: Inversion recovery prepared ultra-short echo time (IR-UTE)-based MRI enables radiation-free visualization of osseous tissue. However, sufficient signal-to-noise ratio (SNR) can only be obtained with long acquisition times. This study proposes a data-driven approach to reconstruct undersampled IR-UTE knee data, thereby accelerating MR-based 3D imaging of bones. Methods: Data were acquired with a 3D radial IR-UTE pulse sequence, implemented using the open-source framework Pulseq. A denoising convolutional neural network (DnCNN) was trained in a supervised fashion using data from eight healthy subjects. Conjugate gradient sensitivity encoding (CG-SENSE) reconstructions of different retrospectively undersampled subsets (corresponding to 2.5-min, 5-min and 10-min acquisition times) were paired with the respective reference dataset reconstruction (30-min acquisition time). The DnCNN was then integrated into a Landweber-based reconstruction algorithm, enabling physics-based iterative reconstruction. Quantitative evaluations of the approach were performed using one prospectively accelerated scan as well as retrospectively undersampled datasets from four additional healthy subjects, by assessing the structural similarity index measure (SSIM), the peak signal-to-noise ratio (PSNR), the normalized root mean squared error (NRMSE), and the perceptual sharpness index (PSI). Results: Both the reconstructions of prospective and retrospective acquisitions showed good agreement with the reference dataset, indicating high image quality, particularly for an acquisition time of 5 min. The proposed method effectively preserves contrast and structural details while suppressing noise, albeit with a slight reduction in sharpness. Conclusion: The proposed method is poised to enable MR-based bone assessment in the knee within clinically feasible scan times.2025-06-13T13:28:53ZPhilipp Hans NunnHenner HuflageJan-Peter GrunzPhilipp GruschwitzOliver SchadThorsten Alexander BleyJohannes Tran-GiaTobias Wechhttp://arxiv.org/abs/2502.01661v4Censor-Aware Semi-Supervised Survival Time Prediction in Lung Cancer Using Clinical and Radiomics Features2025-06-12T23:15:42ZObjectives: Lung cancer poses a significant global health challenge, necessitating improved prognostic methods for personalized treatment. This study introduces a censor-aware semi-supervised learning (SSL) framework that integrates clinical and imaging data, addressing biases in traditional models handling censored data. Methods: We analyzed clinical, PET and CT data from 199 lung cancer patients from public and local data respositories, focusing on overall survival (OS) time as the primary outcome. Handcrafted (HRF) and Deep Radiomics features (DRF) were extracted after preprocessing using ViSERA software and were combined with clinical features (CF). Feature dimensions were optimized using Principal Component Analysis (PCA), followed by the application of supervised learning (SL) and SSL. SSL incorporated pseudo-labeling of censored data to improve performance. Seven regressors and three hazard ratio survival analysis (HRSA) algorithms were optimized using five-fold cross-validation, grid search and external test bootstrapping. Results: For PET HRFs, SSL reduced the mean absolute error (MAE) by 26.5%, achieving 1.55 years with PCA+decision tree regression, compared to SL's 2.11 years with PCA+KNNR (p<0.05). Combining HRFs (CT_HRF) and DRFs from CT images using SSL+PCA+KNNR achieved an MAE of 2.08 years, outperforming SL's 2.26 years by 7.96% (p<0.05). In HRSA, CT_HRF applied to PCA+Component Wise Gradient Boosting Survival Analysis achieved an external c-index of 0.65, effectively differentiating high- and low-risk groups. Conclusions: We demonstrated that the SSL strategy significantly outperforms SL across PET, CT, and CF. As such, censor-aware SSL applied to HRFs from PET images significantly improved survival prediction performance by 26.5% compared to the SL approach.2025-01-31T22:26:19Z11 pages, 4 Figures and 4 TablesArman GorjiAli Fathi JouzdaniNima SanatiRen YuanArman RahmimMohammad R. Salmanpourhttp://arxiv.org/abs/2412.04669v2Practical Global Backprojection-Convolution in Transmission Cone-beam Computed Tomography2025-06-12T22:15:42ZGlobal backprojection-convolution (GBC) is a recently developed theory for exact reconstruction in transmission cone-beam computed tomography (CBCT). It is the first exact inversion theory that applies when the X-ray source points comprise a multidimensional `source locus' $X \subset \mathbb R^3$. Theoretically, GBC is computationally highly expedient due to its structure, but producing a practical computational implementation poses a significant challenge because the method is uniquely vulnerable to four sources of discretisation error: (1) accurate discretisation of a multidimensional locus requires more points than for a 1-dimensional locus, (2) the convolution kernel has infinite range and so the backprojected volume must be of infinite size, (3) the discrete convolution kernel cannot be computed in closed form, and (4) aliasing artefacts in the backprojection are enormously magnified by the convolution step. In this article, we propose an assortment of strategies to mitigate the discretisation errors, at the level of the symbolic algorithm. As a prototype, we deploy the concept on the case where $X$ is a cylinder. The resulting algorithm is evaluated through a series of reconstructions of the 3D Shepp-Logan phantom. As additional validation, we also briefly present a reconstruction from a real experimental dataset.2024-12-05T23:41:57Z16 pages, 9 figuresMurdock GrewarGlenn MyersAndrew Kingstonhttp://arxiv.org/abs/2506.10257v1Enhancing Ultrasound Molecular Imaging: Toward Real-Time RPCA-Based Filtering to Differentiate Bound and Free Microbubbles2025-06-12T00:52:34ZUltrasound molecular imaging (UMI) is an advanced imaging modality that shows promise in detecting cancer at early stages. It uses microbubbles as contrast agents, which are functionalized to bind to cancer biomarkers overexpressed on endothelial cells. A major challenge in UMI is isolating bound microbubble signal, which represents the molecular imaging signal, from that of free-floating microbubbles, which is considered background noise. In this work, we propose a fast GPU-based method using robust principal component analysis (RPCA) to distinguish bound microbubbles from free-floating ones. We explore the method using simulations and measure the accuracy using the Dice coefficient and RMS error as functions of the number of frames used in RPCA reconstruction. Experiments using stationary and flowing microbubbles in tissue-mimicking phantoms were used to validate the method. Additionally, the method was applied to data from ten transgenic mouse models of breast cancer development, injected with B7-H3-targeted microbubbles, and two mice injected with non-targeted microbubbles. The results showed that RPCA using 20 frames achieved a Dice score of 0.95 and a computation time of 0.2 seconds, indicating that 20 frames is potentially suitable for real-time implementation. On in vivo data, RPCA using 20 frames achieved a Dice score of 0.82 with DTE, indicating good agreement between the two, given the limitations of each method.2025-06-12T00:52:34ZHoda S. HashemiDongwoon HyunNathan NguyenJihye BaekArutselvan NatarajanFarbod TabeshAndrew AndrzejekRamasamy PaulmuruganJeremy J. Dahlhttp://arxiv.org/abs/2506.09805v1Automatic Treatment Planning using Reinforcement Learning for High-dose-rate Prostate Brachytherapy2025-06-11T14:46:42ZPurpose: In high-dose-rate (HDR) prostate brachytherapy procedures, the pattern of needle placement solely relies on physician experience. We investigated the feasibility of using reinforcement learning (RL) to provide needle positions and dwell times based on patient anatomy during pre-planning stage. This approach would reduce procedure time and ensure consistent plan quality. Materials and Methods: We train a RL agent to adjust the position of one selected needle and all the dwell times on it to maximize a pre-defined reward function after observing the environment. After adjusting, the RL agent then moves on to the next needle, until all needles are adjusted. Multiple rounds are played by the agent until the maximum number of rounds is reached. Plan data from 11 prostate HDR boost patients (1 for training, and 10 for testing) treated in our clinic were included in this study. The dosimetric metrics and the number of used needles of RL plan were compared to those of the clinical results (ground truth). Results: On average, RL plans and clinical plans have very similar prostate coverage (Prostate V100) and Rectum D2cc (no statistical significance), while RL plans have less prostate hotspot (Prostate V150) and Urethra D20% plans with statistical significance. Moreover, RL plans use 2 less needles than clinical plan on average. Conclusion: We present the first study demonstrating the feasibility of using reinforcement learning to autonomously generate clinically practical HDR prostate brachytherapy plans. This RL-based method achieved equal or improved plan quality compared to conventional clinical approaches while requiring fewer needles. With minimal data requirements and strong generalizability, this approach has substantial potential to standardize brachytherapy planning, reduce clinical variability, and enhance patient outcomes.2025-06-11T14:46:42ZTonghe WangYining FengXiaofeng Yanghttp://arxiv.org/abs/2410.23401v2Plug-and-play superiorization2025-06-10T20:14:20ZThe superiorization methodology (SM) is an optimization heuristic in which an iterative algorithm, which aims to solve a particular problem, is ``superiorized'' to promote solutions that are improved with respect to some secondary criterion. This superiorization is achieved by perturbing iterates of the algorithm in nonascending directions of a prescribed function that penalizes undesirable characteristics in the solution; the solution produced by the superiorized algorithm should therefore be improved with respect to the value of this function. In this paper, we broaden the SM to allow for the perturbations to be introduced by an arbitrary procedure instead, using a plug-and-play approach. This allows for operations such as image denoisers or deep neural networks, which have applications to a broad class of problems, to be incorporated within the superiorization methodology. As proof of concept, we perform numerical simulations involving low-dose and sparse-view computed tomography image reconstruction, comparing the plug-and-play approach to two conventionally superiorized algorithms, as well as a post-processing approach. The plug-and-play approach provides comparable or better image quality in most cases, while also providing advantages in terms of computing time, and data fidelity of the solutions.2024-10-30T19:06:47Z20 pages, 6 figuresJon HenshawAviv GibaliThomas Humphries