https://arxiv.org/api/NbvaKpyqs1kVxtUINfjArMy4YqQ 2026-06-26T23:06:16Z 9008 1230 15 http://arxiv.org/abs/2506.19479v1 An analytical model of depth-dose distributions for carbon-ion beams 2025-06-24T10:14:36Z Improving effective treatment plans in carbon ion therapy, especially for targeting radioresistant tumors located in deep seated regions while sparing normal tissues, depends on a precise and computationally efficient dose calculation model. Although dose calculations are mostly performed using Monte Carlo simulations, the large amount of computational effort required for these simulations hinders their use in clinical practice. To address this gap, we propose, for the first time in the literature, an analytical model for the depth dose distribution of carbon ion beams by adapting and extending Bortfeld proton dose model. The Bortfeld model was modified and expanded by introducing additional terms and parameters to account for the energy deposition and fragmentation effects characteristic of carbon ions. Our model was implemented in MATLAB software to calculate depth-dose distributions of carbon ion beams across the clinical energy range of 100-430 MeV/u. The calculated results for carbon ion energies of 280 MeV/u and 430 MeV/u were compared with Monte Carlo simulation results from TOPAS to assess the precision of our model. It is observed that the results of the proposed model are in good agreement with those of several analytical and experimental studies for clinical carbon ion beams within the therapeutic energy range of 100-400 MeV/u. At 280 MeV/u, the analytical model result exhibited strong consistency with the depth dose curve produced by TOPAS Monte Carlo simulations. However, noticeable discrepancies appeared at higher energies, such as 430 MeV/u, particularly in the Bragg peak height and the dose falloff. In the clinically useful energy range, our model could potentially be an effective tool in carbon ion therapy as an alternative to complex Monte Carlo simulations. It will enable fast dose assessment with accuracy and in real time, thus improving workflow efficiency. 2025-06-24T10:14:36Z 40 pages, 8 figures Fulya Halıcılar Metin Arık http://arxiv.org/abs/2505.19798v2 Comparative study of microscopy methods to assess fish intestinal microvilli 2025-06-24T07:32:10Z The primary function of intestinal microvilli is to increase the surface area of the intestinal lining to maximize nutrient absorption. This is especially important as fish, like other animals, need to efficiently absorb proteins, carbohydrates, lipids, vitamins, and minerals from their digested food to support their growth and energy needs. Despite its importance to the fish health, the small size and dense footprint of microvilli hinders its investigation and necessitates the need of advanced microscopy methods for its visualization. Characterization of the microvilli using super-resolution microscopy provides insights into their structural organization, spatial distribution, and surface properties. Here, we present a comprehensive investigation of different optical, electron and force microscopy methods for analysis of fish microvilli. The super-resolution optical microscopy methods used are 3D structured illumination microscopy (SIM), stimulated emission depletion microscopy (STED), and fluorescence fluctuation based super-resolution microscopy (FF-SRM). We also visualized the intestinal microvilli in fish using diffraction-limited optical microscopy methods including confocal and total internal reflection fluorescence microscopy. Additionally, label-free microscopy methods, such as quantitative phase microscopy (QPM) and bright-field imaging, were also employed. To obtain ultra-high resolution, we used scanning electron microscopy (SEM), transmission electron microscopy (TEM) and atomic force microscopy (AFM). We demonstrate a systematic comparison of these microscopy techniques in resolving and quantifying microvilli features, ranging from 1-2 um structural morphology to 10-100 nm surface details. 2025-05-26T10:29:43Z Ankit Butola Luis E. Villegas-Hernández Dhivya B. Thiyagarajan Bartłomiej Zapotoczny Roy A. Dalmo Balpreet Singh Ahluwalia http://arxiv.org/abs/2506.19372v1 Do cell culturing influence the radiosensitizing effect of gold nanoparticles part 1: scrutinizing recent evidence for data consistency 2025-06-24T07:00:42Z In radiobiological experiments, the cells can either float in suspension or adhere to the walls of the sample holder. When irradiation is performed in the presence of dose modifying agents such as gold nanoparticles (AuNPs), the different shapes of the floating or adherent cells may imply a different dose to the nucleus, with biological consequences such as cell survival. Recently, it has been reported that the survival rate varies by up to a factor of 1.5 for the two cell geometries and by up to a factor of 2 for different orientation of the cells with respect to the incident beam. These results are examined in this paper and possible methodological issues are analyzed. This analysis shows that the simulation setup corresponds to the case of cells in the dose build-up region near the surface of a water phantom, where different depths result in different dose and survival probabilities. The validation of the simulations by comparison with experimental data is misleading, as the apparent agreement is due to a neglect of the quadratic term of the linear-quadratic survival model. The analysis further shows that the reported step-like changes between the survival predicted from the mean dose and the LEM could be explained by the fact that in the entire simulation only in one event an ionizing interaction of a photon took place in an AuNP. It is shown that the probability of this is in the permille range and that the total number of electrons leaving an AuNP, estimated from the reported electron spectrum, is three orders of magnitude higher than the value estimated from the expectation of photon interactions in the AuNPs. This contradiction would be resolved if the AuNP diameter in the simulations were a factor of 10 larger than intended. Another possible explanation for the discrepancies is a hidden bias in the simulation geometry, for example, if the distribution of AuNPs was non-uniform. 2025-06-24T07:00:42Z 14 pages, 6+3 Figures, 4 Tables, to be submitted to Radiation Physics and Chemistry Radiation Physics and Chemistry 240 (2026) 113466, Supplement 1 Hans Rabus Oswald Msosa Mkanda 10.1016/j.radphyschem.2025.113466 http://arxiv.org/abs/2506.19880v1 Physics-Guided Radiotherapy Treatment Planning with Deep Learning 2025-06-23T19:44:56Z Radiotherapy (RT) is a critical cancer treatment, with volumetric modulated arc therapy (VMAT) being a commonly used technique that enhances dose conformity by dynamically adjusting multileaf collimator (MLC) positions and monitor units (MU) throughout gantry rotation. Adaptive radiotherapy requires frequent modifications to treatment plans to account for anatomical variations, necessitating time-efficient solutions. Deep learning offers a promising solution to automate this process. To this end, we propose a two-stage, physics-guided deep learning pipeline for radiotherapy planning. In the first stage, our network is trained with direct supervision on treatment plan parameters, consisting of MLC and MU values. In the second stage, we incorporate an additional supervision signal derived from the predicted 3D dose distribution, integrating physics-based guidance into the training process. We train and evaluate our approach on 133 prostate cancer patients treated with a uniform 2-arc VMAT protocol delivering a dose of 62 Gy to the planning target volume (PTV). Our results demonstrate that the proposed approach, implemented using both 3D U-Net and UNETR architectures, consistently produces treatment plans that closely match clinical ground truths. Our method achieves a mean difference of D95% = 0.42 +/- 1.83 Gy and V95% = -0.22 +/- 1.87% at the PTV while generating dose distributions that reduce radiation exposure to organs at risk. These findings highlight the potential of physics-guided deep learning in RT planning. 2025-06-23T19:44:56Z Stefanos Achlatis Efstratios Gavves Jan-Jakob Sonke http://arxiv.org/abs/2506.18638v1 A Selection of Distributions and Their Fourier Transforms with Applications in Magnetic Resonance Imaging 2025-06-23T13:41:57Z This note presents a rigorous introduction to a selection of distributions along with their Fourier transforms, which are commonly encountered in signal processing and, in particular, magnetic resonance imaging (MRI). In contrast to many textbooks on the principles of MRI, which place more emphasis on the signal processing aspect, this note will take a more mathematical approach. In particular, we will make explicit the underlying topological space of interest and clarify the exact sense in which these distributions and their Fourier transforms are defined. Key results presented in this note involve the Poisson summation formula and the Fourier transform of a Gaussian function via an ordinary differential equation (ODE) argument, etc. Although the readers are expected to have prior exposure to functional analysis and distribution theory, this note is intended to be self-contained. 2025-06-23T13:41:57Z Kaibo Tang http://arxiv.org/abs/2506.01878v3 Monte Carlo Simulation and Dosimetric Analysis of Gold Nanoparticles (AuNPs) in Breast Tissue 2025-06-23T09:19:30Z Precise radiation delivery is critical for effective radiotherapy, and gold nanoparticles (AuNPs) have emerged as promising tools to enhance local dose deposition while sparing the surrounding healthy tissue. In this study, the PENELOPE Monte Carlo code was used to investigate the dosimetry of AuNPs under different conditions and models. The Dose Enhancement Ratio (DER) was studied in water and breast tissue with spherical shapes and in agreement with previously published results. To further analyse the physical interactions of the particles around the AuNP, a Phase Space File (PSF) in a volume around the AuNPs was created. This showed that larger AuNPs lead to increased doses, as expected, yielding DER values exceeding 100 times. Finally, results reveal that in the volume surrounding the AuNP, 80% of emitted electrons originate from photoelectric absorption, leading to Auger electron emission cascades which were analysed in detail. It was also possible to establish a direct relation between number of secondaries and the particle volumes. The Local Effect Model (LEM) was used to determine survival curves in AuNPs of different sizes at different gold concentrations. The last part of this work consisted in analysing a distribution of AuNPs within a flattened cell typical of clonogenic assays where a log-normal distribution of dose was observed. This led to the development of a new, mechanistic, Local Effect Model which, if further validated, can have further applications in-vitro and in-silico. 2025-06-02T17:08:50Z Pedro Teles Catarina Dias João H. Belo Célia Sousa Paula Boaventura Isabel Bravo João Santos Marissa Rylander http://arxiv.org/abs/2506.17849v1 Boosting biocompatibility and mechanical property evolution in a high-entropy alloy via nanostructure engineering and phase transformations 2025-06-21T23:05:16Z High-entropy alloys (HEAs), as multi-component materials with high configurational entropy, have garnered significant attention as new biomaterials; still, their low yield stress and high elastic modulus need to be overcome for future biomedical applications. In this study, nanograin generation is used to enhance the strength and phase transformation is employed to reduce the elastic modulus of a biocompatible Ti-Zr-Hf-Nb-Ta-based HEA. The alloy is treated via the high-pressure torsion (HPT) process, leading to (i) a BCC (body-centered cubic) to omega phase transformation with [101]ω//[011]BCC and [211]omega//[121]BCC through a twining mechanism, (ii) nanograin formation with a mean grain size of 20 nm, and (iii) dislocation generation particularly close to BCC-omega interphase boundaries. These structural and microstructural features enhance hardness, increase tensile strength up to 2130 MPa, achieve tensile elongation exceeding 13%, reduce elastic modulus down to 69 GPa and improve biocompatibility. Additionally, the HEA exhibits improved anodization, resulting in a homogenous distribution of oxide nanotubes on the surface with a smaller tube diameter and a higher tube length compared to pure titanium. These remarkable properties, which are engineered by the generation of defective nanograins and the co-existence of BCC and metastable omega phases, highlight the potential of HEAs treated using severe plastic deformation for future biomedical usage, particularly in the orthopedic sector. 2025-06-21T23:05:16Z Thanh Tam Nguyen Payam Edalati Shivam Dangwal Karina Danielle Pereira Alessandra Cremasco Ricardo Floriano Augusto Ducati Luchessi Kaveh Edalati http://arxiv.org/abs/2506.17536v1 Exploring Strategies for Personalized Radiation Therapy Part I Unlocking Response-Related Tumor Subregions with Class Activation Mapping 2025-06-21T01:24:25Z Personalized precision radiation therapy requires more than simple classification, it demands the identification of prognostic, spatially informative features and the ability to adapt treatment based on individual response. This study compares three approaches for predicting treatment response: standard radiomics, gradient based features, and convolutional neural networks enhanced with Class Activation Mapping. We analyzed 69 brain metastases from 39 patients treated with Gamma Knife radiosurgery. An integrated autoencoder classifier model was used to predict whether tumor volume would shrink by more than 20 percent at a three months follow up, framed as a binary classification task. The results highlight their strength in hierarchical feature extraction and the classifiers discriminative capacity. Among the models, pixel wise CAM provides the most detailed spatial insight, identifying lesion specific regions rather than relying on fixed patterns, demonstrating strong generalization. In non responding lesions, the activated regions may indicate areas of radio resistance. Pixel wise CAM outperformed both radiomics and gradient based methods in classification accuracy. Moreover, its fine grained spatial features allow for alignment with cellular level data, supporting biological validation and deeper understanding of heterogeneous treatment responses. Although further validation is necessary, these findings underscore the promise in guiding personalized and adaptive radiotherapy strategies for both photon and particle therapies. 2025-06-21T01:24:25Z Hao Peng Steve Jiang Robert Timmerman http://arxiv.org/abs/2506.17491v1 Exploring Strategies for Personalized Radiation Therapy Part II Predicting Tumor Drift Patterns with Diffusion Models 2025-06-20T21:58:42Z Radiation therapy outcomes are decided by two key parameters, dose and timing, whose best values vary substantially across patients. This variability is especially critical in the treatment of brain cancer, where fractionated or staged stereotactic radiosurgery improves safety compared to single fraction approaches, but complicates the ability to predict treatment response. To address this challenge, we employ Personalized Ultra-fractionated Stereotactic Adaptive Radiotherapy (PULSAR), a strategy that dynamically adjusts treatment based on how each tumor evolves over time. However, the success of PULSAR and other adaptive approaches depends on predictive tools that can guide early treatment decisions and avoid both overtreatment and undertreatment. However, current radiomics and dosiomics models offer limited insight into the evolving spatial and temporal patterns of tumor response. To overcome these limitations, we propose a novel framework using Denoising Diffusion Implicit Models (DDIM), which learns data-driven mappings from pre to post treatment imaging. In this study, we developed single step and iterative denoising strategies and compared their performance. The results show that diffusion models can effectively simulate patient specific tumor evolution and localize regions associated with treatment response. The proposed strategy provides a promising foundation for modeling heterogeneous treatment response and enabling early, adaptive interventions, paving the way toward more personalized and biologically informed radiotherapy. 2025-06-20T21:58:42Z Hao Peng Steve Jiang Robert Timmerman http://arxiv.org/abs/2406.05220v3 Collimator-less SPECT System Design for Dynamic Whole-body Imaging 2025-06-20T15:38:49Z In this study, we introduce a Compton SPECT system for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The Compton SPECT system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. The system consists of two detectors, providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit Gate. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV), representing the major detectable gamma energies generated from 225Ac. We explore the possibility of using the Compton SPECT system for treatment response monitoring in TAT. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of 225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot to background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at 10 cm distance to the detector is 0.5% with the two energy windows (211-225 keV, 430-450 keV) selected. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings. 2024-06-07T19:07:39Z Yuemeng Feng Arkadiusz Sitek Shadi Abdar Esfahani Hamid Sabet http://arxiv.org/abs/2506.16837v1 Radiochromic Film Dosimetry for VHEE and UHDR: Considerations for the CLEAR Facility and Comparisons with Alanine, RPL and Dosimetry Phantoms 2025-06-20T08:42:00Z Radiochromic films (RCFs) offer valuable two-dimensional dosimetry capabilities with a conceptually simple operating principle that requires minimal investment, making them particularly suitable for very high energy electron (VHEE) FLASH dosimetry where dosimetry standards are currently lacking. However, achieving high-accuracy measurements with RCFs presents significant practical challenges. Without the standardised protocols that ensure reliable outcomes across applications and facilities, knowledge of RCF behaviour becomes essential. This paper identifies common sources of error in RCF preparation, scanning, and processing while proposing specific mitigation strategies to improve accuracy and efficiency. Using our optimised RCF protocol at the CLEAR facility, we demonstrate relative agreement within 5% compared to alanine dosimeters when measuring Gaussian VHEE beams, establishing a foundation for reliable dosimetry in these advanced radiotherapy applications. 2025-06-20T08:42:00Z V. F. Rieker J. J. Bateman L. M. Wroe M. Caloz V. Grilj Y. Q. Aguiar A. Schüller C. Bailat W. Farabolini A. Gilardi C. Robertson P. Korysko A. Malyzhenkov S. Stapnes M. -C. Vozenin M. Dosanjh R. Corsini http://arxiv.org/abs/2506.17359v1 Uncertainties of a Spherical Magnetic Field Camera 2025-06-20T08:35:27Z Spherical harmonic expansions are well-established tools for estimating magnetic fields from surface measurements and are widely used in applications such as tomographic imaging, geomagnetism, and biomagnetism. Although the mathematical foundations of these expansions are well understood, the impact of real-world imperfections, on the uncertainty of the field model has received little attention. In this work, we present a systematic uncertainty propagation analysis for a magnetic field camera that estimates the field from surface measurements using a spherical array of Hall magnetometers arranged in a spherical t-design. A Monte Carlo-based approach is employed to quantify how sensor-related uncertainties, such as calibration errors and positioning inaccuracies, affect the spatial distribution of the estimated field's uncertainty. The results offer insights into the robustness of spherical harmonic methods and help identify the dominant sources of uncertainty in practical implementations. 2025-06-20T08:35:27Z This work has been submitted to the IEEE for possible publication Fynn Foerger Philip Suskin Marija Boberg Jonas Faltinath Tobias Knopp Martin Möddel 10.1109/SENSORS59705.2025.11331079 http://arxiv.org/abs/2407.18337v7 Direct3γ: A Pipeline for Direct Three-gamma PET Image Reconstruction 2025-06-19T14:54:23Z This paper presents a novel image reconstruction pipeline for three-gamma (3-γ) positron emission tomography (PET) aimed at improving spatial resolution and reducing noise in nuclear medicine; the proposed Direct3γ pipeline addresses the inherent challenges in 3-γ PET systems, such as detector imperfections and uncertainty in photon interaction points, with a key feature being its ability to determine the order of interactions through a model trained on Monte Carlo (MC) simulations using the Geant4 Application for Tomography Emission (GATE) toolkit, thus providing the necessary information to construct Compton cones which intersect with the line of response (LOR) to estimate the emission point; the pipeline processes 3-γ PET raw data, reconstructs histoimages by propagating energy and spatial uncertainties along the LOR, and applies a 3-D convolutional neural network (CNN) to refine these intermediate images into high-quality reconstructions, further enhancing image quality through supervised learning and adversarial losses that preserve fine structural details; experimental results show that Direct3γ consistently outperforms conventional 200-ps time-of-flight (TOF) PET in terms of structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). 2024-07-25T18:51:47Z 11 pages, 11 figures, 2 tables Youness Mellak Alexandre Bousse Thibaut Merlin Debora Giovagnoli Dimitris Visvikis 10.1109/TRPMS.2025.3577810 http://arxiv.org/abs/2506.16124v1 Seven-Probe Fiber Detector for Time-Resolved Source Tracking in HDR-Brachytherapy: Experimental Evaluation 2025-06-19T08:19:04Z {\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques. {\bf Methods:} The SSD comprises seven detection cells made of Gd$_2$O$_2$S:Tb, each measuring 0.28 $\pm$ 0.02 mm in diameter and 0.43 $\pm$ 0.02 mm in length, coupled to the microstructured tips of silica optical fibers (110-micron diameter). The probes, spaced 15 mm apart along the fiber axis, are organized into a bundle with a total diameter of less than 0.45 mm. The SSD was tested using a MicroSelectron 9.1 Ci Ir-192 HDR afterloader connected to a BT stainless steel interstitial needle. Detection signals were acquired with an sCMOS camera equipped. Monitoring of dwell times and positions was performed by combining detection signals from all seven probes. {\bf Results:} A total of 4,040 dwell positions were analyzed, covering source-probe spacings from 10 to 36 mm and a source travel range of 62 mm, with dwell times ranging from 0.1 to 19.5 s. The 7SD successfully identified 99.5\% of the dwell positions. In cylindrical coordinates, the measured dwell positions deviated from the planned values by 0.224 $\pm$ 0.155 mm (radial) and 0.077 $\pm$ 0.181 mm (axial, source travel axis). The average deviation from planned dwell times was 0.006 $\pm$ 0.061 s. 99.4\% of the dwell positions were measured within the 1 mm reliability threshold. The remaining 0.6\% of deviations consistently occurred at the initial dwell position of treatment sequences and appear to stem from a systematic source positioning error by the afterloader. Additionally, the detector accurately identified intentional needle mispositioning scenarios with sub-millimeter accuracy. 2025-06-19T08:19:04Z Mathieu Gonod Miguel Angel Suarez Samir Laskri Gwenael Rolin Karine Charriere Emmanuel Dordor Julien Crouzilles Thomas Lihoreau Lionel Pazart Jean-Francois Vinchant Leone Aubignac Thierry Grosjean http://arxiv.org/abs/2503.00198v3 Redefining spectral unmixing for in-vivo brain tissue analysis from hyperspectral imaging 2025-06-18T12:27:26Z In this paper, we propose a methodology for extracting molecular tumor biomarkers from hyperspectral imaging (HSI), an emerging technology for intraoperative tissue assessment. To achieve this, we employ spectral unmixing, allowing to decompose the spectral signals recorded by the HSI camera into their constituent molecular components. Traditional unmixing approaches are based on physical models that establish a relationship between tissue molecules and the recorded spectra. However, these methods commonly assume a linear relationship between the spectra and molecular content, which does not capture the whole complexity of light-matter interaction. To address this limitation, we introduce a novel unmixing procedure that allows to take into account non-linear optical effects while preserving the computational benefits of linear spectral unmixing. We validate our methodology on an in-vivo brain tissue HSI dataset and demonstrate that the extracted molecular information leads to superior classification performance. 2025-02-28T21:35:56Z Martin Hartenberger Huzeyfe Ayaz Fatih Ozlugedik Charly Caredda Luca Giannoni Frédéric Lange Laurin Lux Jonas Weidner Alex Berger Florian Kofler Martin Menten Bruno Montcel Ilias Tachtsidis Daniel Rueckert Ivan Ezhov