https://arxiv.org/api/s9UBU6p9M4sGoV654B5cwvUD0RM 2026-06-26T22:08:32Z 9008 1215 15 http://arxiv.org/abs/2412.06260v2 Evaluation of Coincidence Time Resolution in a liquid xenon detector with silicon photomultipliers 2025-06-27T06:46:45Z This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high-PDE, VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 281 $\pm$ 2 ps FWHM, obtained using a $^{22}$Na calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology. 2024-12-09T07:18:45Z N. Salor-Iguiñiz J. M. Benlloch-Rodríguez R. Esteve C. Romo-Luque R. J. Aliaga V. Álvarez F. Ballester R. Gadea F. Monrabal M. Querol M. Rappaport J. Rodríguez J. Rodríguez-Ponce S. Teruel-Pardo J. F. Toledo R. Torres-Curado P. Ferrario V. Herrero J. J. Gómez-Cadenas 10.1103/vy9h-twqf http://arxiv.org/abs/2506.21886v1 Transcutaneous Interference Spinal Cord Stimulation: Leadfield-Based Pareto Optimization of Electrode Montages for Improved Focality 2025-06-27T03:44:02Z Purpose: This study investigates the feasibility of transcutaneous interferential spinal cord stimulation (tISCS), a novel non-invasive neuromodulation method, using temporal interference to enhance focality and comfort in spinal cord stimulation. The central research question is whether tISCS can achieve targeted activation of spinal cord circuits while reducing unwanted stimulation of skin and muscle tissues, which are common limitations of conventional transcutaneous spinal cord stimulation (tSCS). Methods: A finite element model of the lower thorax was developed to simulate electric field distributions for various skin electrode montages. To address the computational bottleneck associated with high-resolution modeling and montage optimization, we implemented a leadfield-based Pareto optimization strategy to identify the electrode configuration that maximizes the electric field in the spinal cord and minimizes it in off-target tissues. tISCS montages were compared with tSCS montages in terms of focality and stimulation efficiency. Results: Optimized tISCS configurations significantly reduced electric field intensity in the skin by over 20-fold compared to tSCS. The ratio of spinal cord to skin electric fields increased by at least 10-fold, indicating enhanced focality. The injection current efficiency in tISCS can be leveraged to increase spinal cord electric fields by at least 5-fold while keeping skin exposure below the levels observed with tSCS. Conclusion: tISCS enables deeper and more selective spinal cord stimulation compared to tSCS, with substantially reduced off-target effects. This is the first computational demonstration of tISCS feasibility. Leadfield-guided Pareto optimization enables efficient montage selection, providing a foundation for future experimental applications. 2025-06-27T03:44:02Z 18 pages, 5 figures Mariko Teragiwa Leonel E. Medina Alonso Carvajal Kanata Yatsuda Wenwei Yu Jose Gomez-Tames http://arxiv.org/abs/2506.17923v2 A unipolar head gradient for high-field MRI without encoding ambiguity 2025-06-26T13:52:20Z Purpose: MRI gradients with a conventional, bipolar design generally face a trade-off between performance, encoding ambiguity, and circumventing the latter by means of RF selectivity. This problem is particularly limiting in cutting-edge brain imaging performed at field strengths >= 7T and using high-performance head gradients. Methods: To address this issue, the present work proposes to fundamentally eliminate the encoding ambiguity in head gradients by using a unipolar z-gradient design that takes advantage of the signal-free range on one side of the imaging volume. This concept is demonstrated by implementation of a unipolar head gradient for operation at 7T. Results: Imaging in phantoms and in vivo demonstrates elimination of backfolding due to encoding ambiguity. At the same time, the unipolar design achieves efficiency on par with conventional bipolar design, resulting in high amplitude and slew-rate performance. Conclusion: The prospect of gradient systems based on a unipolar design holds promise for all advanced neuroimaging that demands high gradient performance. It will make the greatest difference at 7T and beyond where the absence of ambiguity removes a key concern and constraint in terms of RF behaviour and instrumentation. 2025-06-22T07:28:15Z Markus Weiger Johan Overweg Franciszek Hennel Emily Louise Baadsvik Samuel Bianchi Oskar Björkqvist Roger Luechinger Jens Metzger Eric Michael Thomas Schmid Lauro Singenberger Urs Sturzenegger Erik Oskam Gerrit Vissers Jos Koonen Wout Schuth Jeroen Koeleman Martino Borgo Klaas Paul Pruessmann 10.1002/mrm.70098 http://arxiv.org/abs/2506.21153v1 Mapping intratumoral heterogeneity through PET-derived washout and deep learning after proton therapy 2025-06-26T11:23:04Z The distribution of produced isotopes during proton therapy can be imaged with Positron Emission Tomography (PET) to verify dose delivery. However, biological washout, driven by tissue-dependent processes such as perfusion and cellular metabolism, reduces PET signal-to-noise ratio (SNR) and limits quantitative analysis. In this work, we propose an uncertainty-aware deep learning framework to improve the estimation of washout parameters in post-proton therapy PET, not only enabling accurate correction for washout effects, but also mapping intratumoral heterogeneity as a surrogate marker of tumor status and treatment response. We trained the models on Monte Carlo-simulated data from eight head-and-neck cancer patients, and tested them on four additional head-and-neck and one liver patient. Each patient was represented by 75 digital twins with distinct tumoral washout dynamics and imaged 15 minutes after treatment, when slow washout components dominate. We also introduced "washed-out" maps, quantifying the contribution of medium and fast washout components to the loss in activity between the end of treatment and the start of PET imaging. Trained models significantly improved resolution and accuracy, reducing average absolute errors by 60% and 28% for washout rate and washed-out maps, respectively. For intratumoral regions as small as 5 mL, errors predominantly fell below thresholds for differentiating vascular status, and the models generalized across anatomical areas and acquisition delays. This study shows the potential of deep learning in post-proton therapy PET to non-invasively map washout kinetics and reveal intratumoral heterogeneity, supporting dose verification, tumor characterization, and treatment personalization. The framework is available at https://github.com/pcabrales/ppw.git. 2025-06-26T11:23:04Z Pablo Cabrales David Izquierdo-García Víctor V. Onecha Mailyn Pérez-Liva Luis Mario Fraile José Manuel Udías Joaquín L. Herraiz http://arxiv.org/abs/2505.00950v2 Large speed-up of quantum emitter detection via quantum interference 2025-06-26T07:18:09Z Quantum emitters are a key resource in quantum technologies, microscopy, and other applications. The ability to rapidly detect them is useful both for quality control in engineered emitter arrays and for high-contrast imaging of naturally occurring emitters. Using full photon-counting statistics and optimal Bayesian hypothesis testing, we show that extended Hong-Ou-Mandel interference between quantum emission and a coherent field enables orders-of-magnitude speed-ups in emitter detection under realistic noise and loss. Strikingly, the performance advantage improves as loss and background noise increase, and persists for incoherent emission. Taken together with prior demonstrations of extended Hong-Ou-Mandel interference, this suggest that substantial performance gains are achievable with current technology under realistic, non-ideal conditions. This offers a new approach to fast, low-intensity imaging and for emitter characterization in large-scale quantum systems. Fundamentally, the discovery that quantum interference and measurements, used together, are more robust to both loss and noise than standard measurement techniques opens the possibility of broad applications across quantum metrology. 2025-05-02T01:43:40Z Main text, 6 pages, 3 figures; Supplementary Material, 11 pages, 4 figures Warwick P. Bowen http://arxiv.org/abs/2506.20781v1 Development and in silico imaging trial evaluation of a deep-learning-based transmission-less attenuation compensation method for DaT SPECT 2025-06-25T19:11:12Z Quantitative measures of dopamine transporter (DaT) uptake in caudate, putamen, and globus pallidus derived from DaT-single-photon emission computed tomography (SPECT) images are being investigated as biomarkers to diagnose, assess disease status, and track the progression of Parkinsonism. Reliable quantification from DaT-SPECT images requires performing attenuation compensation (AC), typically with a separate X-ray CT scan. Such CT-based AC (CTAC) has multiple challenges, a key one being the non-availability of X-ray CT component on many clinical SPECT systems. Even when a CT is available, the additional CT scan leads to increased radiation dose, costs, and complexity, potential quantification errors due to SPECT-CT misalignment, and higher training and regulatory requirements. To overcome the challenges with the requirement of a CT scan for AC in DaT SPECT, we propose a deep learning (DL)-based transmission-less AC method for DaT-SPECT (DaT-CTLESS). An in silico imaging trial, titled ISIT-DaT, was designed to evaluate the performance of DaT-CTLESS on the regional uptake quantification task. We observed that DaT-CTLESS yielded a significantly higher correlation with CTAC than that between UAC and CTAC on the regional DaT uptake quantification task. Further, DaT-CLTESS had an excellent agreement with CTAC on this task, significantly outperformed UAC in distinguishing patients with normal versus reduced putamen SBR, yielded good generalizability across two scanners, was generally insensitive to intra-regional uptake heterogeneity, demonstrated good repeatability, exhibited robust performance even as the size of the training data was reduced, and generally outperformed the other considered DL methods on the task of quantifying regional uptake across different training dataset sizes. These results provide a strong motivation for further clinical evaluation of DaT-CTLESS. 2025-06-25T19:11:12Z Zitong Yu Md Ashequr Rahman Zekun Li Chunwei Ying Hongyu An Tammie L. S. Benzinger Richard Laforest Jingqin Luo Scott A. Norris Abhinav K. Jha http://arxiv.org/abs/2506.20718v1 One Giant Leap for Womankind: First Menstrual Cups Tested in Space Flight Conditions 2025-06-25T18:00:01Z In the early days of space exploration, when Sally Ride was offered 100 tampons for a week-long mission, menstrual medical devices first began to be used in space conditions. Since then, hormonal menstrual suppression has become the preferred method for managing menstruation in space, offering significant advantages. However, this is not an option for astronauts who choose to menstruate. The lack of sustainable menstrual technologies will pose challenges for long-duration missions to the Moon and Mars, where astronauts may spend years in space. The AstroCup mission represents the first effort to test menstrual cups in spaceflight, evaluating their durability and functionality. Through material integrity tests and functional assessments using a rheological analogue of human blood, we demonstrate the resilience of menstrual cups and discuss their implications for sustainable menstrual management in future lunar and Martian missions. 2025-06-25T18:00:01Z 8 pages, 6 figures. Submitted for peer review Ligia F. Coelho Catarina Miranda Joao Canas Miguel Morgado Diogo Nunes Andre F. Henriques Adam B. Langeveld http://arxiv.org/abs/2503.09978v2 A Conditional Point Cloud Diffusion Model for Deformable Liver Motion Tracking Via a Single Arbitrarily-Angled X-ray Projection 2025-06-25T16:49:52Z Deformable liver motion tracking using a single X-ray projection enables real-time motion monitoring and treatment intervention. We introduce a conditional point cloud diffusion model-based framework for accurate and robust liver motion tracking from arbitrarily angled single X-ray projections (PCD-Liver), which estimates volumetric liver motion by solving deformable vector fields (DVFs) of a prior liver surface point cloud based on a single X-ray image. The model is patient-specific and consists of two main components: a rigid alignment model to estimate the liver's overall shifts and a conditional point cloud diffusion model that further corrects for liver surface deformations. Conditioned on motion-encoded features extracted from a single X-ray projection via a geometry-informed feature pooling layer, the diffusion model iteratively solves detailed liver surface DVFs in a projection angle-agnostic manner. The liver surface motion estimated by PCD-Liver serves as a boundary condition for a U-Net-based biomechanical model to infer internal liver motion and localize liver tumors. A dataset of ten liver cancer patients was used for evaluation. The accuracy of liver point cloud motion estimation was assessed using root mean square error (RMSE) and 95th-percentile Hausdorff distance (HD95), while liver tumor localization error was quantified using center-of-mass error (COME). The mean (standard deviation) RMSE, HD95, and COME of the prior liver or tumor before motion estimation were 8.82(3.58) mm, 10.84(4.55) mm, and 9.72(4.34) mm, respectively. After PCD-Liver motion estimation, the corresponding values improved to 3.63(1.88) mm, 4.29(1.75) mm, and 3.46(2.15) mm. Under highly noisy conditions, PCD-Liver maintained stable performance. This study presents an accurate and robust framework for deformable liver motion estimation and tumor localization in image-guided radiotherapy. 2025-03-13T02:27:26Z 26 pages, 9 figures Jiacheng Xie Hua-Chieh Shao Yunxiang Li Shunyu Yan Chenyang Shen Jing Wang You Zhang 10.1088/1361-6560/addf0e http://arxiv.org/abs/2410.09868v2 Tracking the Morphological Evolution of Neuronal Dendrites by First-Passage Analysis 2025-06-25T15:11:10Z A high degree of structural complexity arises in dynamic neuronal dendrites due to extensive branching patterns and diverse spine morphologies, which enable the nervous system to adjust function, construct complex input pathways and thereby enhance the computational power of the system. Owing to the determinant role of dendrite morphology in the functionality of the nervous system, recognition of pathological changes due to neurodegenerative disorders is of crucial importance. We show that the statistical analysis of a temporary signal generated by cargos that have diffusively passed through the complex dendritic structure yields vital information about dendrite morphology. As a feasible scenario, we propose engineering mRNA-carrying multilamellar liposomes to diffusively reach the soma and release mRNAs, which are translated into a specific protein upon encountering ribosomes. The concentration of this protein over a large population of neurons can be externally measured, as a detectable temporary signal. Using a stochastic coarse-grained approach for first-passage through dendrites, we connect the key morphological properties affected by neurodegenerative diseases -- including the density and size of spines, the extent of the tree, and the segmental increase of dendrite diameter towards soma -- to the characteristics of the evolving signal. Thus, we establish a direct link between the dendrite morphology and the statistical characteristics of the detectable signal. Our approach provides a fast noninvasive measurement technique to indirectly extract vital information about the morphological evolution of dendrites in the course of neurodegenerative disease progression. 2024-10-13T15:03:44Z 18 pages, 8 figures Biophys. J. 125, 64, 2026 Fabian H. Kreten Barbara A. Niemeyer Ludger Santen Reza Shaebani 10.1016/j.bpj.2025.11.005 http://arxiv.org/abs/2506.20696v1 IMC-PINN-FE: A Physics-Informed Neural Network for Patient-Specific Left Ventricular Finite Element Modeling with Image Motion Consistency and Biomechanical Parameter Estimation 2025-06-25T11:37:34Z Elucidating the biomechanical behavior of the myocardium is crucial for understanding cardiac physiology, but cannot be directly inferred from clinical imaging and typically requires finite element (FE) simulations. However, conventional FE methods are computationally expensive and often fail to reproduce observed cardiac motions. We propose IMC-PINN-FE, a physics-informed neural network (PINN) framework that integrates imaged motion consistency (IMC) with FE modeling for patient-specific left ventricular (LV) biomechanics. Cardiac motion is first estimated from MRI or echocardiography using either a pre-trained attention-based network or an unsupervised cyclic-regularized network, followed by extraction of motion modes. IMC-PINN-FE then rapidly estimates myocardial stiffness and active tension by fitting clinical pressure measurements, accelerating computation from hours to seconds compared to traditional inverse FE. Based on these parameters, it performs FE modeling across the cardiac cycle at 75x speedup. Through motion constraints, it matches imaged displacements more accurately, improving average Dice from 0.849 to 0.927, while preserving realistic pressure-volume behavior. IMC-PINN-FE advances previous PINN-FE models by introducing back-computation of material properties and better motion fidelity. Using motion from a single subject to reconstruct shape modes also avoids the need for large datasets and improves patient specificity. IMC-PINN-FE offers a robust and efficient approach for rapid, personalized, and image-consistent cardiac biomechanical modeling. 2025-06-25T11:37:34Z Siyu Mu Wei Xuan Chan Choon Hwai Yap http://arxiv.org/abs/2506.20283v1 Do cell culturing influence the radiosensitizing effect of gold nanoparticles part 2: scrutinizing the methodology producing recent evidence 2025-06-25T09:44:25Z When irradiation is performed with gold nanoparticles (AuNPs), a different shape of cells in suspension or adherent to walls may result in different probability of cell survival. In a recent study, differences of up to a factor of 2 were found between the predicted survival of floating and adherent cells. The present work aims to quantify the biases introduced by the simulation setup and the use of voxelized geometry in conjunction with the local effect model for cell survival. The results show that simulated irradiation of a cell near the surface with an incident beam matched to the cell dimensions results in dose values that are by a factor of about 50 lower than the dose to cells deeper in the medium when irradiated with a Co-60 spectrum and lateral beam dimensions in the centimeter range. Furthermore, the number of ionizing photon interactions in gold nanoparticles in a cell near the surface is lower by a factor of about 2 than for cells at 5 mm and 1 cm depth. Using the average dose in voxels of size in the order of 200 nm for assessing cell survival with the local effect model (LEM) leads to an underestimation of the number of lesions from a single ionized AuNP by roughly two orders of magnitude and thus to an overestimation of cell survival. The effect of cell geometry on the survival rate was examined for approximate cell geometries and 100 kV x-ray irradiation, for which the probability of photon interaction in gold nanoparticles is by more than two orders of magnitude higher than for Co-60 irradiation. The results show that the effects are negligible for 5 nm nanoparticles at the concentration of AuNPs considered in preceding work. For 50 nm nanoparticles and thus a thousand times higher mass fraction of gold, significant reduction in cell survival is found, with a clear additional reduction predicted by the LEM as compared to the prediction based on mean dose to the nucleus. 2025-06-25T09:44:25Z 16 pages, 6+1 Figs., 3+1 Tables Radiation Physics and Chemistry 240 (2026) 113466 Hans Rabus Oswald Msosa Mkanda 10.1016/j.radphyschem.2025.113466 http://arxiv.org/abs/2505.03935v2 Physics-informed Neural Networks Enable High Fidelity Shear Wave Viscoelastography across Multiple organs 2025-06-25T02:45:04Z Tissue viscoelasticity has been recognized as a crucial biomechanical indicator for disease diagnosis and therapeutic monitoring. Conventional shear wave elastography techniques depend on dispersion analysis and face fundamental limitations in clinical scenarios. Particularly, limited wave propagation data with low signal-to-noise ratios, along with challenges in discriminating between dual dispersion sources stemming from viscoelasticity and finite tissue dimensions, pose great difficulties for extracting dispersion relation. In this study, we introduce SWVE-Net, a framework for shear wave viscoelasticity imaging based on a physics-informed neural network (PINN). SWVE-Net circumvents dispersion analysis by directly incorporating the viscoelasticity wave motion equation into the loss functions of the PINN. Finite element simulations reveal that SWVE-Net quantifies viscosity parameters within a wide range (0.15-1.5 Pa*s), even for samples just a few millimeters in size, where substantial wave reflections and dispersion occur. Ex vivo experiments demonstrate its applicability across various organs, including brain, liver, kidney, and spleen, each with distinct viscoelasticity. In in vivo human trials on breast and skeletal muscle tissues, SWVE-Net reliably assesses viscoelastic properties with standard deviation-to-mean ratios below 15%, highlighting robustness under real-world constraints. SWVE-Net overcomes the core limitations of conventional elastography and enables reliable viscoelastic characterization where traditional methods fall short. It holds promise for applications such as grading hepatic lipid accumulation, detecting myocardial infarction boundaries, and distinguishing malignant from benign tumors. 2025-05-06T19:28:28Z Ziying Yin Yuxi Guo Jiayi Pu Yuxuan Jiang Shiyu Ma Guo-Yang Li Yanping Cao http://arxiv.org/abs/2506.18229v2 The role of dendritic spines in water exchange measurements with diffusion MRI: Time-Dependent Single Diffusion Encoding MRI 2025-06-24T21:42:05Z Time-dependent diffusion MRI (dMRI) with single diffusion encoding (SDE) probes water dynamics in biological tissues, but signal interpretation depends on microstructure. While prior work focused on restricted/hindered diffusion and membrane permeation, diffusion-mediated exchange between dendritic shafts and spines in gray matter (GM) remains understudied. We hypothesize that impermeable spiny dendrites produce time-dependent SDE signals mimicking permeative exchange and investigate how spine density biases exchange time estimates. Using Monte Carlo simulations and narrow escape theory, we quantify spine-shaft exchange times (3-26 ms), matching cortical permeative exchange estimates. A modified two-compartment Karger model characterizes time-dependent SDE signals but yields biased exchange estimates, reflecting spine volume fraction rather than morphology. Unaccounted diffusion-mediated exchange introduces up to 80% bias in NEXI/SMEX model estimates. We propose an extended three-compartment Karger model incorporating both diffusion-mediated (spine-shaft) and permeative (intra-extracellular) exchange. However, this model cannot uniquely separate membrane permeability from spine volume effects. Our findings emphasize that dendritic spines should be considered in SDE-based exchange studies and caution against attributing exchange solely to permeability. Advanced methods are needed to disentangle these mechanisms in GM. 2025-06-23T01:33:19Z Kadir Şimşek Arthur Chakwizira Markus Nilsson Marco Palombo http://arxiv.org/abs/2507.01977v1 An Integrated Lab on a CD Microfluidic Platform for High-Efficiency Blood Cell Separation and Passive Mixing 2025-06-24T16:31:22Z Blood accounts for 7-8% of total body weight, with an average adult containing 4.5 to 6 quarts. It delivers oxygen and nutrients to cells, removes waste products, supports immunity, and regulates body temperature. Comprising over 4,000 components, including plasma, platelets, erythrocytes, and leukocytes, blood presents a challenge for isolating specific cell types due to its heterogeneity. In autologous therapies, target cells may be as rare as one per million background cells. This study presents the development of a compact disc (CD)-based microfluidic device for high-throughput, label-free separation of blood components. The system integrates three main modules on a single disk: cell sorting, fluid control, and cell lysis. The initial module utilizes Pinched Flow Fractionation (PFF) to separate red blood cells, white blood cells, and platelets based on size, achieving 99.99% efficiency. A capillary valve directs the sorted cells to the lysis module, where a chemical reagent is used to rupture cell membranes for downstream analysis. To enhance lysis efficiency, a micro mixer was incorporated using two zigzag geometries with internal barriers. The mixing performance of both designs was evaluated to determine optimal fluid interaction. This integrated, multifunctional CD platform offers a compact and effective solution for isolating and processing specific blood cells, with potential applications in diagnostics and personalized medicine. 2025-06-24T16:31:22Z 13 Pages, 5 Figures Reza Lotfi Navaei Haniyeh Tehrani http://arxiv.org/abs/2406.13598v5 Cryogenic cesium iodide as a potential PET material 2025-06-24T15:26:50Z Total Body PET (TBPET) scanners have recently demonstrated the ability to significantly reduce both acquisition time and the administered radioactive dose, thanks to their increased sensitivity. However, their widespread adoption is limited by the high costs associated with the current available systems. Cesium iodide (CsI), though historically less favored for PET due to its lower stopping power and light yield compared to crystals like LYSO, shows remarkable improvement when operated at cryogenic temperatures ($\sim$100 K). Under these conditions, CsI light yield rises dramatically to about 100 photons/keV, providing excellent energy resolution and good coincidence time resolution at a lower cost - typically 3 to 5 times cheaper than other crystals at parity of radiation length. In our study, we measured the light yield, the energy resolution and the coincidence time resolution as a function of temperature for two pure CsI crystals read out by a pair of silicon photomultipliers (SiPMs). An energy resolution of 6.3% FWHM and a coincidence time resolution of 1.84 ns at 511 keV were achieved at a temperature of 104 K. These results point towards the potential of cryogenic CsI as a cost-effective, high-performance material for TBPET scanners. 2024-06-19T14:41:21Z 12 pages, 7 figures JINST 20 P06038 (2025) S. R. Soleti A. Castillo J. I. Collar M. del Barrio-Torregrosa C. Echeverria M. Seemann D. Zerzion J. J. Gómez Cadenas 10.1088/1748-0221/20/06/P06038