https://arxiv.org/api/wP3X2LHl2lTClPxRVRUmHCWLaHA2026-09-11T00:59:44Z920012015http://arxiv.org/abs/2608.04863v2Prior-Based Multi-Voltage Threshold Sampling as a Structured Inverse Problem2026-08-06T09:53:20ZPrior-based Multi-Voltage Threshold (MVT) sampling reconstructs pulse parameters from sparse threshold-crossing times rather than full waveforms, making parameter recovery inherently a model-dependent inverse problem. However, prior-based MVT has lacked a formal mathematical statement, leaving identifiability, stochastic error propagation, and threshold design without a unified theoretical foundation. We formalize prior-based MVT for strictly unimodal pulse families as a structured inverse problem. On that foundation, we develop the first unified theory of prior-based MVT, comprising deterministic identifiability conditions, a stochastic timing-error model with leading-order mismatch bias, and a nuisance-profiled threshold-design theory centered on an effective-information equation for robust single-event and partial-trigger multi-event operation. We instantiate the framework for the bi-exponential pulse model, derive executable design recipes, and validate the resulting predictions on a 10,000-pulse $^{22}$Na/LYSO/SiPM dataset. The experiments confirm that the framework yields useful threshold designs in the photopeak regime while also revealing the regime boundary at which partial triggering and model mismatch limit the predictive power of Fisher-guided optimization. These results provide the first unified mathematical foundation for prior-based MVT and recast it from an empirical threshold heuristic as a principled inferential framework.2026-08-05T13:57:13ZAo QiuQingguo Xiehttp://arxiv.org/abs/2608.05665v1The Virtual Hearing Clinic (VHC)- a modular online platform for hearing research and hearing health care2026-08-06T07:02:37ZObjective: The aim is to introduce the concept of the Virtual Hearing Clinic (VHC), give an overview of the current status and exemplify its feasibility with data from a diagnostics module obtaining hearing thresholds. Design: The architecture of the VHC is described and an overview of functional modules that have been developed and tested in respective studies is given. As a functional example data from an experiment is presented. Hearing thresholds were obtained from 20 subjects with hearing loss with the VHC using the Graded Response Bracketing (GraBr) procedure and compared to reference thresholds obtained with a clinical audiometer. Results: Median VHC-based hearing thresholds over all frequencies did not differ significantly from the reference with values of 57.4 dB SPL (VHC) and 55.5 dB SPL (reference). The shape of the frequency-dependent thresholds was also found to be very similar for 250 Hz to 4 kHz. Results for 6 kHz showed larger differences. Conclusion: The VHC is suitable as a mobile hearing health application and to collect data for audiological research. By offering flexibility in time and location it can lower barriers for hearing health care and enable collecting large datasets that are needed for the advancement of data-driven audiology.2026-08-06T07:02:37Z12 pages, 3 figures, 2 tablesLena Schell-MajoorMedical Physics Universitaet Oldenburg GermanyBig Data in Medicine Universitaet Oldenburg GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyKim M. RullmannAuditory Signal Processing and Hearing Devices Universitaet Oldenburg GermanyHoerzentrum Oldenburg gGmbH, GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyTobias BrunsFraunhofer Institute for Media Technology Oldenburg GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyTheresa JansenHoerzentrum Oldenburg gGmbH, GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyVolker HohmannAuditory Signal Processing and Hearing Devices Universitaet Oldenburg GermanyHoerzentrum Oldenburg gGmbH, GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyHendrik KayserAuditory Signal Processing and Hearing Devices Universitaet Oldenburg GermanyHoerzentrum Oldenburg gGmbH, GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, GermanyBirger KollmeierMedical Physics Universitaet Oldenburg GermanyHoerzentrum Oldenburg gGmbH, GermanyFraunhofer Institute for Media Technology Oldenburg GermanyCluster of Excellence Hearing4all, Universitaet Oldenburg, D-26111 Oldenburg, Germanyhttp://arxiv.org/abs/2608.05471v1A Foundational EDM2-Based Generative Model for High-Resolution Synthetic Fetal Ultrasound Imaging from Open Datasets2026-08-05T23:39:48ZPrenatal ultrasound imaging is key for assessing fetal health, but AI progress is limited by scarce, privacy-restricted, and hard-to-annotate datasets. We propose a high-resolution fetal ultrasound synthesis framework based on the EDM2 diffusion architecture, trained on multiple public datasets to generate 512x512 images across six anatomical classes. Our method achieved improved image quality with lower FID scores and enhanced downstream fetal plane classification, reaching 93.36% ensemble accuracy after fine-tuning, surpassing real-data-only training. Clinical evaluation by an experienced fetal ultrasound specialist (10+ years) on 100 images yielded a mean realism score of 2.67/5, with real images rated higher than synthetic. Artefacts included smoothing, speckle irregularities, and anatomical inconsistencies. Code, data, models and other resources to reproduce this work are available at https://github.com/xfetus/fetal-ultrasound-edm2.2026-08-05T23:39:48ZShort paper for the 30th Conference on Medical Image Understanding and AnalysisHarvey ManneringYilin ZhangZiao LiuZhiwu HuangJacqueline MatthewMiguel Xochicalehttp://arxiv.org/abs/2603.24889v2Quantitative Chemical Exchange Saturation Transfer Imaging with Golden-Angle Radial k-Space and Locally Low-Rank Reconstruction2026-08-04T17:51:58ZChemical exchange saturation transfer magnetic resonance fingerprinting (CEST-MRF) is a promising quantitative molecular imaging technique. To reduce scan time, current CEST-MRF implementations typically use echo-planar imaging (EPI) readouts, which are prone to geometric distortion and signal dropout. In this study, we developed a motion-robust geometrically accurate CEST-MRF method using radial k-space sampling, locally low-rank reconstruction, and neural network-based quantification. The acquisition schedule was optimized using deep learning, and its accuracy was validated in numerical simulations with digital phantoms. The number of spokes per measurement was determined through simulations and in vivo ablation studies in healthy volunteers. Five healthy subjects underwent repeated scans, and regions of interest were defined for analysis. Tissue maps generated with the proposed method were compared with values obtained from nonlinear least-squares (NLS) fitting of multi-saturation-power z-spectra. Motion sensitivity and test-retest reproducibility were evaluated using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Clinical feasibility was demonstrated in a subject with a history of remote middle cerebral artery infarction. The results show that 3D quantitative CEST maps can be acquired in 11 minutes using 34 spokes per measurement. Numerical simulations yielded mean errors below 14% for all tissue parameters, while in vivo parameter estimates agreed well with both NLS-derived values and prior brain CEST-MRF studies. The mean ICC across all tissue maps was 0.92 in white matter and 0.87 in gray matter, with mean inter-subject CVs of 5.4% and 3.4%, respectively. For the radial acquisition, the mean error between motion and no-motion conditions was 8.6%. Changes in CEST-MRF tissue parameters were consistent with clinically diagnosed cystic gliosis.2026-03-26T00:11:06Z30 pages, 10 figuresOuri CohenElizabeth J. SuttonRobert J. YoungRicardo Otazohttp://arxiv.org/abs/2511.15336v2On the phase aberration estimation using common mid-angle correlations2026-08-04T12:15:28ZPhase aberrations, despite degrading ultrasound images, also encode valuable information about the spatial distribution of the speed of sound in tissue. In pulse-echo ultrasound, we can quantify them by exploiting speckle correlations. Among existing strategies, correlations between steered acquisitions that share a common mid-angle have proven particularly effective for inferring the speed of sound. Their phases can be linearly related to the phase aberrations undergone by both the incident and reflected wavefronts. This relationship has so far been demonstrated only through geometric arguments based on point reflectors. Here, we develop a rigorous theoretical formalism that extends this relationship to the speckle regime, completing the previously established linear model and clarifying its underlying assumptions. More importantly, we build on this formalism to analyze correlation-phase fluctuations arising from aberration-induced speckle decorrelation. The analysis reveals that phase variance is governed by the relative loss of coherence, which increases approximately linearly with the square of the correlation phases. Local correlation-phase estimates therefore become increasingly uncertain as their magnitude grows. Experimental measurements in a uniform tissue-mimicking phantom show excellent agreement with the predicted variance. Beyond providing a theoretical basis for advancing speed-of-sound imaging, this formalism establishes the accuracy limit of common-mid-angle correlation phases, offering a benchmark for evaluating more advanced aberration-estimation techniques.2025-11-19T10:56:27Z12 pages, 7 figuresNaiara Korta MartiartuMichael Jaegerhttp://arxiv.org/abs/2607.11101v2Quantum Generalized Equivalent Uniform Dose (QgEUD): A Simulation Method for Phase-Dependent Radiobiological Dose Effects2026-08-04T07:48:39ZThe generalized equivalent uniform dose (gEUD) provides a biologically interpretable measure of heterogeneous dose distributions and is widely used in radiobiological modeling. However, because gEUD depends solely on dose magnitude, it does not explicitly account for collective cellular interactions or phase-dependent biological responses. Here, we propose a quantum generalized equivalent uniform dose (QgEUD), which extends the conventional gEUD kernel into the complex domain by introducing a phase variable while preserving the original dose-weighting formalism. This formulation yields a two-dimensional response surface that recovers conventional gEUD on the real axis and incorporates interaction-dependent radiobiological effects through phase modulation. The local response of the surface is characterized by a Kähler metric, providing an intrinsic measure of sensitivity to dose weighting and phase perturbations. To demonstrate the framework, local dose elements are modeled by an Ising Hamiltonian with dose- and phase-dependent interactions, and equilibrium response maps are obtained using Metropolis Monte Carlo simulations. Simulations in a virtual radiotherapy phantom preserve the overall dose distribution while producing spatially modulated biological-effect maps governed by collective interactions. The corresponding Kähler response identifies regions exhibiting enhanced sensitivity beyond dose magnitude alone, and parameter sensitivity analysis confirms stable convergence under practical simulation conditions. These results establish QgEUD as a quantum-inspired extension of gEUD that integrates heterogeneous dose aggregation, phase-dependent interactions, and geometric response within a unified mathematical framework, providing a basis for interaction-aware radiobiological modeling and future quantum-compatible optimization.2026-07-13T05:19:32ZYusuke Anetaihttp://arxiv.org/abs/2602.14315v2Complex Wavelet-Based Sinogram Segmentation for Metal Artifact Reduction in Cone-Beam CT2026-08-04T03:27:22ZMetal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These artifacts degrade image quality and limit the reliability of subsequent medical analysis. We propose a projection-domain metal artifact reduction method based on analytical metal segmentation in the three-dimensional sinogram using the three-dimensional Dual-Tree Complex Wavelet Transform, where directional wavelet coefficients are exploited to extract the wavefront set and singular support of metal structures. The resulting segmentation enables projection-domain inpainting and artifact-reduced reconstruction by combining metal-free and metal-only reconstructions. The proposed approach is evaluated on both simulated and clinical cone-beam computed tomography data and consistently reduces metal artifacts compared to conventional image-domain hard-thresholding methods. The results demonstrate improved visual quality and robustness in clinically realistic scenarios, highlighting the potential of analytically grounded, non-learned projection-domain segmentation for metal artifact reduction.2026-02-15T21:33:25ZSiiri RautioAlexander MeaneySalla-Maaria Latva-ÄijöHarshit AgrawalMikael BrixDinidu JayakodySamuli Siltanen10.1088/1361-6560/ae8fb3http://arxiv.org/abs/2607.26498v2HERMES: A Hybrid Ensemble for Head-and-Neck Tumor Segmentation, TN Staging, and Recurrence-Free Survival on PET/CT2026-08-04T00:02:12ZWe present HERMES (Hybrid Ensemble for Radiotherapy-target segmentation, Malignancy staging, and Event-free Survival), a single containerized algorithm for the three HECKTOR 2026 subtasks: segmentation of the primary tumor (GTVp) and pathological lymph nodes (GTVn), radiological T/N staging, and recurrence-free survival (RFS), computed from a paired FDG-PET/CT scan and an electronic health record. A 10-fold ensemble of STU-Net Small networks produces the segmentation; the predicted mask then drives two downstream tasks. Rather than pass a generic radiomics vector to the staging models, we derive from the predicted masks a compact set of geometry features aligned with the size and number axes of AJCC/UICC 7th-edition radiological N/T staging. On internal cross-validation these features raise N-stage balanced accuracy from 0.691 to 0.720 (+0.030), our largest single design gain, at lower feature dimensionality. For prognosis we combine complementary deep and clinical risk experts in an equal-weight ensemble, and train one deep expert with a concordance-tracking survival loss of our own, whose value approximates the concordance index during training. Every component was selected on honest out-of-fold predictions under a regularization-oriented protocol, with no tuning on the public validation set, and deployed as two decorrelated submissions. On the HECKTOR 2026 validation leaderboard, HERMES achieved a weighted score of 0.6454 (Mean Dice 0.641, T balanced accuracy 0.580, N balanced accuracy 0.642, RFS C-index 0.679) and qualified for the testing phase. Team: AMC_HNC.2026-07-29T05:47:18Z12 pages, 4 figures, 3 tables, conferenceKai WangMeixu ChenElie NasrRyan LanningMoyed Miftenhttp://arxiv.org/abs/2608.02889v1Real-time tissue-equivalent measurement of individual clinical radiotherapy pulses2026-08-03T21:19:58ZWe apply the precision tools of cavity-enhanced absorption sensing to clinical oncology, demonstrating a dosimeter paradigm in which a centimeter-scale volume of water serves as a tissue-equivalent sensing medium. Our proof-of-concept, all-optical scheme achieves real-time readout of clinical radiation pulses with a nominal single-pulse resolution of 90 $μ$Gy. This demonstration paves the way toward fiber-integrated, micron-scale devices for $\textit{in situ}$ universal absolute dosimetry during treatment.2026-08-03T21:19:58Z21 pages, 4 figuresFernanda C. Rodrigues-MachadoKatherine SzaboJingyi BianSimon BernardTanner ConnellShirin A. EngerLilian ChildressJack C. Sankeyhttp://arxiv.org/abs/2511.07088v2Validation of Fully-Automated Deep Learning-Based Fibroglandular Tissue Segmentation for Efficient and Reliable Quantitation of Background Parenchymal Enhancement in Breast MRI2026-08-03T15:22:18ZBackground parenchymal enhancement (BPE) on breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) shows potential as a breast cancer risk marker. Clinically, BPE is qualitatively assessed by radiologists, but quantitative BPE measures offer potential for more precise risk evaluation. This study evaluated an existing open-source, fully-automated deep learning-based (DL-based) method for segmenting fibroglandular tissue (FGT) to quantify BPE and compared it to a semi-automated fuzzy c-means method. Using breast MRI examinations from 100 women, we evaluated segmentation agreement, concordance across quantitative BPE metrics, and associations with qualitative BPE. The quality of FGT segmentations from both methods was scored by a radiologist. While the DL-based and semi-automated methods showed good agreement for quantitative BPE measurements, DL-based measures more strongly correlated with qualitative BPE assessments and DL-based segmentations were scored as higher quality by the radiologist. Our findings suggest that DL-based FGT segmentation enhances efficiency for objective BPE quantification and may improve standardized breast cancer risk assessment.2025-11-10T13:24:31ZProc. SPIE 13926, Medical Imaging 2026: Computer-Aided Diagnosis, 139262F (2026)Yu-Tzu KuoAnum S. KazerouniVivian Y. ParkWesley SurentoSuleeporn SujichantararatDaniel S. HippeHabib RahbarSavannah C. Partridge10.1117/12.3087337http://arxiv.org/abs/2608.02135v1Cardiovascular Digital Twins from Physics Based to Data Driven Approaches2026-08-03T12:23:44ZCardiovascular digital twins aim to create patient-specific computational models that evolve with clinical data to support diagnosis, prognosis, and therapy optimisation. Mechanistic models provide physiological interpretability but remain computationally demanding, whereas data-driven approaches improve scalability yet risk limited robustness. Emerging physics-informed, graph-based, and hybrid methods integrate physical constraints with relational learning across vascular networks. We review modelling paradigms, data assimilation frameworks, validation challenges, and translational pathways toward clinically deployable cardiovascular digital twins.2026-08-03T12:23:44ZEmmanuel LweleFrancis Chikwetohttp://arxiv.org/abs/2608.02012v1Performance and prospects of polyurethane-based scintillators for neutron and gamma radiation detection2026-08-03T10:10:04ZOrganic scintillators have been used for decades to detect gamma rays or fast neutrons at low cost. Despite extensive efforts it is still difficult to combine stability, ruggedness, high light yield, and decent pulse-shape discrimination (PSD) in a single scintillator material. We took the unusual approach of embedding phosphors and wavelengths shifters in a solid polyurethane matrix, trying to combine the robustness of a common construction material with scintillating properties and PSD performance. The plastic scintillators resulting from years of research ultimately meet these intentions. Moreover, the production process is less demanding and less complex than that of conventional plastic scintillators. It allows to directly integrate light sensors or electronics into the scintillator. This opens the door for the construction of extremely compact and robust plastic detectors for the simultaneous detection of fast neutrons and gamma rays. This paper presents basic recipes and properties of scintillators based on this novel conception and discusses first applications in neutron imaging and personal radiation protection.2026-08-03T10:10:04Z7 pages, 5 figures; invited paper to be presented at the 2026 SPIE Optics + Photonics in San Diego, CAOlga MaiatskaTorsten DuennebackeRoland HillebrandsAchim KreuelsMartin KreuelsGuntram PauschFalko ScherwinskiAndreas WolfJuergen Steinhttp://arxiv.org/abs/2608.00831v1Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration2026-08-01T19:15:17ZHead-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ-at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patient's treatment-day anatomy can be predicted before image acquisition by transferring longitudinal change from a population database. We propose a digital-twin framework built on a pretrained foundation-model deformable registration network used without patient-specific training. A first registration aligns a prior patient's planning CT to the target and carries the prior's during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the prior's planning-to-QACT change, which is then applied to the target's own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-correlation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging.2026-08-01T19:15:17ZAccepted for publication in the Proceedings of the 29th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2026), Workshop on Digital Twins for Healthcare (DT4H)Yizhou WuYuheng LiXiaofeng YangChih-Wei Changhttp://arxiv.org/abs/2608.00760v1Variational Inference Using a Differentiable Multigrid Linear Solver2026-08-01T16:45:23ZGradient-based Bayesian inference methods require efficient access to Jacobian and adjoint-Jacobian operators of high-dimensional forward models. While multigrid solvers provide near-optimal complexity for elliptic partial differential equations, they are rarely available in forms compatible with automatic differentiation (AD). We develop a differentiable multigrid solver for steady-state diffusion-absorption problems and derive its adjoint operations analytically through the full multigrid hierarchy. The resulting solver, DMGS, is implemented in C++ and interfaced with JAX to provide efficient Jacobian-vector and vector-Jacobian products for variational inference in the NIFTy framework. We validate the approach on a 3D inverse problem involving diffuse radiative transfer in tissue, reconstructing an effective radiative source from Monte Carlo-simulated data. The reconstruction reproduces the data at a reduced chi-squared of 1.1 and generalizes to 32 independent validation datasets. Benchmarks against a JAX-native multigrid implementation show comparable runtimes and consistently lower peak memory for the hand-derived adjoint, with modest reverse-mode overhead. These results establish differentiable multigrid solvers as practical building blocks for variational inference in PDE-constrained problems.2026-08-01T16:45:23Z18 pages, 13 figures, 1 tableAndrés RamírezPhilipp HaimDavid FögerTorsten A. EnßlinPhilipp FrankPhilipp GschwandtnerDominik JüstelPhilipp MertschVo Hong Minh PhanLaurin SödingHanieh ZandinejadRalf Kissmannhttp://arxiv.org/abs/2608.12386v1A microscopic computational simulation of [18F]FDG transport and metabolism identifies valid regimes for compartmental analysis2026-07-31T23:59:17Z18F-fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET), combined with compartmental modeling, is a powerful non-invasive imaging method for assessing cellular metabolism. However, classical two- and three-tissue compartment models assume homogeneous [18F]FDG distribution within the tissue, which needs justification, and the definition and interpretation of rate constants across these models is not always consistent. To address these issues, we develop a finite difference solver to simulate [18F]FDG transport and metabolism within a 1 mm3 tissue volume, representing the smallest volume resolvable by PET. Our simulations reveal sub-millimeter heterogeneity in [18F]FDG distribution and show that the measured PET signal is dependent not only on cellular metabolic activity but also on interstitial [18F]FDG diffusivity, vascular permeability, and vascular architecture. We further demonstrate that our finite-difference simulation reduces to a three-tissue compartment model when interstitial [18F]FDG concentration is homogeneous. Furthermore, this simplified model itself reduces to the two-tissue compartment model when vascular permeability is sufficiently high. This work quantitatively links vascular permeability, vascular architecture, cellular uptake kinetics, [18F]FDG diffusivity, and acquisition time. It also unifies the two- and three-tissue compartment models and identifies their applicable regimes. These findings deepen our understanding of [18F]FDG transport kinetics and enhance the interpretability of dynamic [18F]FDG-PET imaging.2026-07-31T23:59:17ZZhong, X., & Pratx, G. (2026). A microscopic computational simulation of [18F] FDG transport and metabolism identifies valid regimes for compartmental analysis. Physics in Medicine & Biology, 71(12), 125002Xiaoxu ZhongGuillem Pratx10.1088/1361-6560/ae74af