https://arxiv.org/api/emd4I3IDfqpzuyYOz4M3ecKcue02026-06-26T20:06:17Z9008118515http://arxiv.org/abs/2507.06536v1Circulating tumor cell detection in cancer patients using in-flow deep learning holography2025-07-09T04:36:59ZCirculating tumor cells (CTCs) are cancer cells found in the bloodstream that serve as biomarkers for early cancer detection, prognostication, and disease monitoring. However, CTC detection remains challenging due to low cell abundance and heterogeneity. Digital holographic microscopy (DHM) offers a promising, label-free method for high-throughput CTC identification by capturing superior morphological information compared to traditional imaging methods, while remaining compatible with in-flow data acquisition. We present a streamlined DHM-based system that integrates microfluidic enrichment with deep learning-driven image analysis, supplemented by immunofluorescent profiling, to improve the sensitivity and specificity of CTC enumeration. Specifically, our platform combines inertial microfluidic preprocessing with dual-modality imaging, integrating holography with fluorescence sensing of up to two markers. A deep learning model, trained on a diverse set of healthy blood samples and cancer cell lines, and executed in real-time, provides a morphological confidence on a cell-by-cell basis that may then be combined with immunofluorescence criteria for enumeration. In a pilot study, we demonstrate significantly higher CTC counts in patients with late-stage prostate cancer (n=13) compared to healthy controls (n=8), with a patient-level false positive rate of 1 cell/mL. Notably, nearly two-thirds of identified CTCs were EpCAM-negative but PSMA positive (a prostate specific epithelial marker), suggesting that traditional use of EpCAM as an epithelial marker for CTCs may lead to false negatives. These findings highlight the potential of DHM for applications including but not limited to screening, diagnostics, and precision oncology.2025-07-09T04:36:59Z35 pages, 10 figures, 5 tablesKevin MalleryNathaniel R. BristowNicholas HellerYash TravadiAli ArafaKaylee KamalanathanCatalina Galeano-GarcesMahdi AhmadiGrant SchaapAlexa HeschOlivia HedeenZikora IzuoraJoel HapkeJeffrey MillerArjun ViswanathanIvo BabrisSongyi BaeTuan LeTony ClackoEmmanuel S. AntonarakisBadrinath R. KonetyJustin M. DrakeJiarong Honghttp://arxiv.org/abs/2501.03548v33D Single-shot CEST imaging at 3T Based on True FISP Readout2025-07-08T10:18:39ZTo simultaneously fit multiple-pool effects, spectrally selective 3D CEST imaging typically requires single-shot readouts to save time. However, to date, FLASH and EPI have been the primary pulse sequences used for this purpose. They suffer from low SNR or image distortion related to B0 field inhomogeneity. In this work, we developed a 3D single-shot CEST sequence using true fast imaging with steady-state precession (True FISP) readout, also known as bSSFP, and optimized the scanning parameters through simulations. The performance of the CEST sequence was validated using an egg white phantom, ten healthy volunteers, and a patient with a brain tumor on a 3T human scanner. Subsequently, the proposed CEST sequence using True FISP was compared with the commonly used FLASH-based CEST sequence, focusing on SNR and image contrast, while maintaining identical pre-saturation modes, repetition time, echo time and scan time. In the simulation experiments, the maximum CEST signal obtained from the True FISP was significantly greater than that obtained from the FLASH sequence. In the egg white phantom, the SNRs of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effect images obtained from the True FISP were 68.3% and 57.0% higher than those obtained from the FLASH sequence, respectively. In healthy volunteers, saturated images collected with the True FISP sequence at 3.5 ppm showed an approximate 84% increase in mean temporal SNR compared to those collected with the FLASH sequence. Compared to the FLASH sequence, the CEST images obtained from the True FISP sequence could display more detailed brain tissue structures of both normal individuals and the patient with a brain tumor. Therefore, due to the high SNR inherent in the sequence, True FISP has the potential to be used for fast and high-quality 3D image readout of CEST contrasts in clinical applications.2025-01-07T05:48:08Z38 pages, 9 figuresNMR in Biomedicine 38 (2025): e70109Yupeng WuQifan PangZhichao WangGaiying LiCaixia FuMengqiu CaoXingrui WangDongmei JiangDejun SheYang SongYu ZhaoJianqi Li10.1002/nbm.70109http://arxiv.org/abs/2507.05702v1Noninvasive Focused Ultrasound Spinal Cord Stimulation in Humans: A Computational Feasibility Study2025-07-08T06:25:38ZBackground: Trans-spinal FUS (tsFUS) has recently been shown promise in modulating spinal reflexes in rodents, opening new avenues for spinal cord interventions in motor control and pain management. However, anatomical differences between rodents and human spinal cords require careful targeting strategies and transducer design adaptations for human applications. Aim: This study aims to computationally explore the feasibility of tsFUS in the human spinal cord by leveraging the intervertebral acoustic window and vertebral lamina. Method: Acoustic simulations were performed using an anatomically detailed human spinal cord model with an adapted single-element focusing transducer (SEFT) to investigate the focality and intensity of the acoustic quantities generated within the spinal cord. Results: Sonication through the intervertebral acoustic window using an adapted transducer achieved approximately 2-fold higher intensity and up to 20% greater beam overlap compared to commercial SEFT. Precise transducer positioning was critical; a 10 mm vertical shift resulted in a reduction of target intensity by approximately 7-fold. The vertebral level also substantially influenced the sonication outcomes, with the thoracic spine achieving 6-fold higher intensity than the cervical level. Sonication through the vertebral lamina resulted in approximately 2.5-fold higher intraspinal intensity in the cervical spine. Conclusion and Significance: This study presents the first systematic, anatomically realistic computational model for the feasibility of tsFUS in humans. Quantifying the trade-offs between acoustic path, vertebral level, and transducer geometry offers foundational design and procedural guidelines for the design and safety of spinal FUS protocols, supporting future studies of trans-spinal FUS in humans.2025-07-08T06:25:38Z33 pages, 7 figuresKoharu IsomuraWenwei YuJose Gomez-Tameshttp://arxiv.org/abs/2505.20499v2Mathematical models for therapeutic approaches involving electric conductors or shielding2025-07-08T04:08:33ZWe set up a mathematical model for a DC current in a human tissue that shows an attenuation effect in an extended circuit. We give a positive lower bound on the time duration over which this is guaranteed to happen in terms of the parameters of the model. We also discuss shielding and coupling in the context of electrical aspects of biological processes.2025-05-26T20:01:37ZExtended sections 2,4Tatyana Barronhttp://arxiv.org/abs/2507.05388v1Scanner-based real-time automated volumetry reporting of the fetus, amniotic fluid, placenta and umbilical cord for fetal MRI at 0.55T2025-07-07T18:20:05ZPurpose: This work aims to enable real-time automated intra-uterine volumetric reporting and fetal weight estimation for fetal MRI, deployed directly on the scanner. Methods: A multi-region segmentation nnUNet was trained on 146 bSSFP images of 73 fetal subjects (coronal and axial orientations) for the parcellation of the fetal head, fetal body, placenta, amniotic fluid and umbilical cord from whole uterus bSSFP stacks. A reporting tool was then developed to integrate the segmentation outputs into an automated report, providing volumetric measurements, fetal weight estimations, and z-score visualisations. The complete pipeline was subsequently deployed on a 0.55T MRI scanner, enabling real-time inference and fully automated reporting in the duration of the acquisition. Results: The segmentation pipeline was quantitatively and retrospectively evaluated on 36 stacks of 18 fetal subjects and demonstrated sufficient performance for all labels, with high scores (>0.98) for the fetus, placenta and amniotic fluid, and 0.91 for the umbilical cord. The prospective evaluation of the scanner deployment step was successfully performed on 50 cases, with the regional volumetric reports available directly on the scanner. Conclusions: This work demonstrated the feasibility of multi-regional intra-uterine segmentation, fetal weight estimation and automated reporting in real-time. This study provides a robust baseline solution for the integration of fully automated scanner-based measurements into fetal MRI reports.2025-07-07T18:20:05ZSara Neves SilvaAlena UusHadi WaheedSimi BansalKamilah St ClairWendy NormanJordina Aviles VerderaDaniel CrombTomas WoodgateMilou van PoppelJohannes K SteinwegJacqueline MatthewKuberan PushparajahDavid LloydVanessa KyriakopoulouDimitris SiasakosAnna DavidJoseph V HajnalLisa StoryMary A RutherfordJana Hutterhttp://arxiv.org/abs/2507.05329v1Differentiation of Wild-Type and CRISPR-Modified Colon Cancer Cells Using Brillouin Microscopy2025-07-07T17:53:48ZThis study investigates the mechanical properties of colon cancer cells through Brillouin microscopy, focusing on the differentiation between wild-type (WT) and CRISPR-modified cells. Brillouin microspectroscopy, a non-invasive technique, was employed to measure Brillouin shifts and full width at half maximum (FWHM) values of the cells in vitro. Using a custom-built confocal Brillouin microspectrometer, both WT and CRISPR-modified cells exhibited distinct mechanical responses. Statistical analysis revealed that WT cells had different stiffness and viscosity compared to CRISPR-modified cells, as indicated by their Brillouin shift and FWHM values. The data suggest that Brillouin spectroscopy offers a viable method to differentiate between normal and mutated cells at the subcellular level, providing new insights into cellular mechanical properties relevant to cancer research. These findings hold potential for advancing non-invasive diagnostic techniques and understanding cellular mechanics in oncology.2025-07-07T17:53:48ZAPS March Meeting 2025 Proceeding. https://summit.aps.org/events/OD01/12. arXiv admin note: substantial text overlap with arXiv:2507.05186APS March Meeting Abstracts 2025 (2025) OD01-012Mykyta KizilovVsevolod CheburkanovVladislav V. Yakovlevhttp://arxiv.org/abs/2501.16570v2Comprehensive characterization and validation of a fast-resolving (1000 Hz) plastic scintillator for ultra-high dose rate electron dosimetry2025-07-07T16:39:21ZBackground: The normal tissue sparing effect of ultra-high dose rate irradiation (>40 Gy/s, UHDR), as compared to conventional dose rate (CONV), has attracted significant research interest for FLASH radiotherapy (RT). Accurate, dose rate independent, fast-responding dosimeters capable of resolving the spatiotemporal characteristics of UHDR beams are urgently needed to facilitate FLASH research and support its clinical translation. Tissue-equivalent scintillators, with millimeter-level spatial resolution and millisecond-level temporal resolution, possess these required characteristics and show strong potential for use in UHDR dosimetry. Purpose: We investigated the performance of the HYPERSCINT RP-FLASH scintillator system at up to 1000 Hz sampling frequency (fs) for UHDR electron beam dosimetry. Methods: The scintillator was exposed to CONV and UHDR electron irradiation using a LINAC-based FLASH platform. Its spectral characteristics were delineated with a four-component calibration, followed by a signal-to-dose calibration using 18 MeV CONV electron beam. The dose linearity and dosimetric accuracy in response to CONV and UHDR irradiation at 1 and 1000 Hz fs were quantified against ion chamber and EBT-XD film measurements. The response of the scintillator system was investigated as a function of beam energy (6 and 18 MeV), field size (2x2 to 25x25 cm2), dose per pulse (DPP, 0.8 to 2.3 Gy/pulse), and pulse repetition frequency (PRF, 30 to 180 Hz). Relative signal sensitivity was quantified against accumulated dose to account for the scintillator's radiation degradation. Pulse-resolved dose measurements at 18 MeV UHDR, obtained using the scintillator with 1000 Hz fs for a train of 10 pulses at 180 Hz PRF, were validated with a PMT-fiber optic scattered radiation detector.2025-01-27T23:28:16ZLixiang GuoBanghao ZhouYi-Chun TsaiKai JiangViktor IakovenkoKen Kang-Hsin Wanghttp://arxiv.org/abs/2411.07503v3A Novel Automatic Real-time Motion Tracking Method in MRI-guided Radiotherapy Using Enhanced Tracking-Learning-Detection Framework with Automatic Segmentation2025-07-07T14:03:30ZBackground and Purpose: Accurate motion tracking in MRI-guided Radiotherapy (MRIgRT) is essential for effective treatment delivery. This study aimed to enhance motion tracking precision in MRIgRT through an automatic real-time markerless tracking method using an enhanced Tracking-Learning-Detection (ETLD) framework with automatic segmentation. Materials and Methods: We developed a novel MRIgRT motion tracking and segmentation method by integrating the ETLD framework with an improved Chan-Vese model (ICV), named ETLD+ICV. The ETLD framework was upgraded for real-time cine MRI, including advanced image preprocessing, no-reference image quality assessment, an enhanced median-flow tracker, and a refined detector with dynamic search region adjustments. ICV was used for precise target volume coverage, refining the segmented region frame by frame using tracking results, with key parameters optimized. The method was tested on 3.5D MRI scans from 10 patients with liver metastases. Results: Evaluation of 106,000 frames across 77 treatment fractions showed sub-millimeter tracking errors of less than 0.8mm, with over 99% precision and 98% recall for all subjects in the Beam Eye View(BEV)/Beam Path View(BPV) orientation. The ETLD+ICV method achieved a dice global score of more than 82% for all subjects, demonstrating the method's extensibility and precise target volume coverage. Conclusion: This study successfully developed an automatic real-time markerless motion tracking method for MRIgRT that significantly outperforms current methods. The novel method not only delivers exceptional precision in tracking and segmentation but also shows enhanced adaptability to clinical demands, making it an indispensable asset in improving the efficacy of radiotherapy treatments.2024-11-12T03:01:39ZShengqi ChenZilin WangJianrong DaiShirui QinYing CaoRuiao ZhaoJiayun ChenGuohua WuYuan Tanghttp://arxiv.org/abs/2311.14745v3Eikonal phase retrieval: Unleashing the fourth generation sources potential for enhanced propagation based tomography on biological samples2025-07-07T08:06:20ZThe evolution of synchrotrons towards higher brilliance beams has increased the possible sample-to-detector propagation distances for which the source confusion circle does not lead to geometrical blurring. This makes it possible to push near-field propagation driven phase contrast enhancement to the limit, revealing low contrast features which would otherwise remain hidden under an excessive noise. Until today this possibility was hindered, in many objects of scientific interest, by the simultaneous presence of strong phase gradient regions and low contrast features. The strong gradients, when enhanced with the now possible long propagation distances, induce such strong phase effects that the linearisation assumptions of current state-of-the-art single-distance phase retrieval filters are broken, and the resulting image quality is jeopardized. Here, we introduce a new iterative phase-retrieval algorithm and compare it with the Paganin phase-retrieval algorithm, in both the monochromatic and polychromatic cases, obtaining superior image quality. In the polychromatic case the comparison was done with an extrapolated Paganin algorithm obtained by reintroducing, into our phase retrieval algorithm, the linearization approximations underlying the Paganin forward model. Our work provides an innovative algorithm which efficiently performs the phase retrieval task over the entire near-field range, producing images of exceptional quality for mixed attenuation objects.2023-11-23T00:55:35ZAlessandro MironeJoseph BrunetLeandre AdmansRenaud BoistelMorgane SowinskiCamille BerruyerHenri PaynoElodie BollerPierre PaleoClaire L. WalshPeter D. LeePaul Tafforeauhttp://arxiv.org/abs/2506.20277v3Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography2025-07-07T04:23:58ZIn the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical image quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.2025-06-25T09:39:59Z40 pages, 2 figuresT. E. GureyevD. M. PaganinK. M. PavlovA. MaksimenkoH. M. Quineyhttp://arxiv.org/abs/2409.05255v2Label-free evaluation of lung and heart transplant biopsies using tissue autofluorescence-based virtual staining2025-07-07T00:59:30ZOrgan transplantation serves as the primary therapeutic strategy for end-stage organ failures. However, allograft rejection is a common complication of organ transplantation. Histological assessment is essential for the timely detection and diagnosis of transplant rejection and remains the gold standard. Nevertheless, the traditional histochemical staining process is time-consuming, costly, and labor-intensive. Here, we present a panel of virtual staining neural networks for lung and heart transplant biopsies, which digitally convert autofluorescence microscopic images of label-free tissue sections into their brightfield histologically stained counterparts, bypassing the traditional histochemical staining process. Specifically, we virtually generated Hematoxylin and Eosin (H&E), Masson's Trichrome (MT), and Elastic Verhoeff-Van Gieson (EVG) stains for label-free transplant lung tissue, along with H&E and MT stains for label-free transplant heart tissue. Subsequent blind evaluations conducted by three board-certified pathologists have confirmed that the virtual staining networks consistently produce high-quality histology images with high color uniformity, closely resembling their well-stained histochemical counterparts across various tissue features. The use of virtually stained images for the evaluation of transplant biopsies achieved comparable diagnostic outcomes to those obtained via traditional histochemical staining, with a concordance rate of 82.4% for lung samples and 91.7% for heart samples. Moreover, virtual staining models create multiple stains from the same autofluorescence input, eliminating structural mismatches observed between adjacent sections stained in the traditional workflow, while also saving tissue, expert time, and staining costs.2024-09-09T00:18:48Z25 Pages, 5 FiguresBME Frontiers, AAAS (2025)Yuzhu LiNir PillarTairan LiuGuangdong MaYuxuan QiKevin de HaanYijie ZhangXilin YangAdrian J. CorreaGuangqian XiaoKuang-Yu JenKenneth A. IczkowskiYulun WuWilliam Dean WallaceAydogan Ozcan10.34133/bmef.0151http://arxiv.org/abs/2507.04111v1Quantum computing for genomics: conceptual challenges and practical perspectives2025-07-05T17:41:10ZWe assess the potential of quantum computing to accelerate computation of central tasks in genomics, focusing on often-neglected theoretical limitations. We discuss state-of-the-art challenges of quantum search, optimization, and machine learning algorithms. Examining database search with Grover's algorithm, we show that the expected speedup vanishes under realistic assumptions. For combinatorial optimization prevalent in genomics, we discuss the limitations of theoretical complexity in practice and suggest carefully identifying problems genuinely suited for quantum acceleration. Given the competition from excellent classical approximate solvers, quantum computing could offer a speedup in the near future only for a specific subset of hard enough tasks in assembly, gene selection, and inference. These tasks need to be characterized by core optimization problems that are particularly challenging for classical methods while requiring relatively limited variables. We emphasize rigorous empirical validation through runtime scaling analysis to avoid misleading claims of quantum advantage. Finally, we discuss the problem of trainability and data-loading in quantum machine learning. This work advocates for a balanced perspective on quantum computing in genomics, guiding future research toward targeted applications and robust validation.2025-07-05T17:41:10Z14 pages, 5 figuresPRX Life 3, 047001, 2025Aurora MaurizioGuglielmo Mazzola10.1103/h49j-bsc6http://arxiv.org/abs/2507.03325v1Cancer cytoplasm segmentation in hyperspectral cell image with data augmentation2025-07-04T06:18:50ZHematoxylin and Eosin (H&E)-stained images are commonly used to detect nuclear or cancerous regions in cells from images captured by a microscope. Identifying cancer cytoplasm is crucial for determining the type of cancer; hence, obtaining accurate cancer cytoplasm regions in cell images is important. While CMOS images often lack detailed information necessary for diagnosis, hyperspectral images provide more comprehensive cell information. Using a deep learning model, we propose a method for detecting cancer cell cytoplasm in hyperspectral images. Deep learning models require large datasets for learning; however, capturing a large number of hyperspectral images is difficult. Additionally, hyperspectral images frequently contain instrumental noise, depending on the characteristics of the imaging devices. We propose a data augmentation method to account for instrumental noise. CMOS images were used for data augmentation owing to their visual clarity, which facilitates manual annotation compared to original hyperspectral images. Experimental results demonstrate the effectiveness of the proposed data augmentation method both quantitatively and qualitatively.2025-07-04T06:18:50ZRebeka SultanaHibiki HoribeTomoaki MurakamiIkuko Shimizuhttp://arxiv.org/abs/2507.03186v1In vivo imaging of central nervous system fluid spaces using synchrotron radiation-based micro computed tomography2025-07-03T21:38:30ZCurrent approaches to in vivo imaging of the mouse central nervous system (CNS) do not offer a combination of micrometer resolution and a whole-brain field of view. To address this limitation, we introduce an approach based on synchrotron radiation-based hard X-ray micro computed tomography (SR$μ$CT). We performed intravital SR$μ$CT acquisitions of mouse CNS fluid spaces at three synchrotron radiation facilities. Imaging was conducted on both anesthetized free-breathing and ventilated animals, with and without retrospective cardiac gating. We achieved whole-brain imaging at 6.3 $μ$m uniform voxel size, observed the distribution of cerebrospinal fluid (CSF) contrast agent over time and quantified choroid plexus movement. SR$μ$CT bridges the gap between multiphoton microscopy and magnetic resonance imaging, offering dynamic imaging with micrometer-scale resolution and whole-organ field of view. Intravital SR$μ$CT will play a crucial role in validating and integrating hypotheses on CSF dynamics and solute transport by providing unique data that cannot be acquired otherwise.2025-07-03T21:38:30Z45 pages, 7 figuresMarta Girona AlarcónWilly KuoMattia HumbelChristine TannerLuca FardinBritta BauschYann DeckerIrene SperaGriffin RodgersHans DeyhleAlberto BravinMasato HoshinoArash PanahifarKentaro UesugiSergei GasilovPetr PleskačYuansheng ZhangDiane de ZélicourtAmandine BrennaAhmad Kamal HamidPooya Razzaghi KhamesiBritta EngelhardtSteven T. ProulxBert MüllerVartan Kurtcuogluhttp://arxiv.org/abs/2502.05050v2Calibration of a $Δ$E-E telescope based on CeBr$_3$ scintillator for secondary charged particles measurements in hadron therapy2025-07-03T09:43:23ZHadrontherapy is an established cancer treatment method that enables a more localized dose deposition compared to conventional radiotherapy, potentially reducing the dose to surrounding healthy tissues in certain clinical cases. However, a key limitation in current treatment planning lies in the limited experimental data available for the characterization of secondary particles generated by nuclear interactions of the primary beam with tissues, which directly impacts the accuracy of Monte Carlo tools and analytical models used in dose calculations. Indeed, this leads to the adoption of larger safety margins and can limit the use of hadrontherapy for treating certain complex or sensitive tumor locations.
This work is part of the context of the characterization of secondary charged particles generated by ion beams in the energy range relevant for particle therapy applications, using a $ΔE-E$ telescope comprising a CeBr$_3$ crystal scintillator and a plastic scintillator. The calibration and response of this telescope to ions commonly used in clinical settings is presented in this work, highlighting adherence to Birks' law for accurate energy measurements.
This study is the first to optimize a $ΔE-E$ telescope combining CeBr$_3$ and plastic scintillators specifically for secondary particle detection in hadrontherapy. It represents an essential step toward the experimental acquisition of nuclear data, enabling accurate measurement and identification of secondary charged particles generated by therapeutic beams in tissue-equivalent materials. The system is designed for use in controlled experimental setups that reproduce clinical conditions, with the goal of improving the predictive accuracy of treatment planning software through enhanced Monte Carlo simulation inputs.2025-02-07T16:14:43ZL. GessonJ. GrossC. MozziC. ReibelCh. FinckS. HigueretT. D. LeE. TraykovJ. C. ThomasN. ArborM. PulliaG. HarmantM. Vanstalle