https://arxiv.org/api/PzzHSPWvFVtHpxt1QB71aTihv7U2026-06-26T18:53:22Z9008117015http://arxiv.org/abs/2507.10871v1GALDS: A Graph-Autoencoder-based Latent Dynamics Surrogate model to predict neurite material transport2025-07-15T00:22:00ZNeurons exhibit intricate geometries within their neurite networks, which play a crucial role in processes such as signaling and nutrient transport. Accurate simulation of material transport in the networks is essential for understanding these biological phenomena but poses significant computational challenges because of the complex tree-like structures involved. Traditional approaches are time-intensive and resource-demanding, yet the inherent properties of neuron trees, which consists primarily of pipes with steady-state parabolic velocity profiles and bifurcations, provide opportunities for computational optimization. To address these challenges, we propose a Graph-Autoencoder-based Latent Dynamics Surrogate (GALDS) model, which is specifically designed to streamline the simulation of material transport in neural trees. GALDS employs a graph autoencoder to encode latent representations of the network's geometry, velocity fields, and concentration profiles. These latent space representations are then assembled into a global graph, which is subsequently used to predict system dynamics in the latent space via a trained graph latent space system dynamic model, inspired by the Neural Ordinary Differential Equations (Neural ODEs) concept. The integration of an autoencoder allows for the use of smaller graph neural network models with reduced training data requirements. Furthermore, the Neural ODE component effectively mitigates the issue of error accumulation commonly encountered in recurrent neural networks. The effectiveness of the GALDS model is demonstrated through results on eight unseen geometries and four abnormal transport examples, where our approach achieves mean relative error of 3% with maximum relative error <8% and demonstrates a 10-fold speed improvement compared to previous surrogate model approaches.2025-07-15T00:22:00ZTsung Yeh HsiehYongjie Jessica Zhanghttp://arxiv.org/abs/2507.22068v1Biomimetic Engineering of a Fortified Ice Composite with Enhanced Mechanical Properties2025-07-14T13:19:44ZThis work presents BioPykrete, a new sustainable bio-composite material created from ice, nano-crystalline cellulose (CNC), and a tailor-made chimera protein designed to bind the two together. We developed and produced the chimera protein by linking AFPIII, an ice-binding protein, with CBM3a, a CNC-binding protein. As the suspension freezes, the CNC chains self-organize into a reinforcing network between the ice crystals. This structural enhancement limits crack propagation to typical pore sizes, allowing BioPykrete to avoid the brittle and sudden failure commonly associated with ice. Instead, it exhibits an elastic-like response to stress, making it suitable for construction and engineering applications. With compressive strength comparable with concrete, BioPykrete offers a sustainable and biodegradable alternative to construction materials suitable for the harsh arctic regions of the world where traditional methods are ineffective, and resources are scarce. Engineering chimera proteins with specific affinity to more than a single material type may help improve or tailor the properties of other composite materials.2025-07-14T13:19:44ZChen AdarYulia BaronBaruch RofmanMaya Bar-DolevLiat BahariVictor YashunskyVera SirotinskayaOded ShoseyovIdo Braslavskyhttp://arxiv.org/abs/2406.04495v2The Associated Volume sampling algorithm as an alternative method for the calculation of ionisation cluster size distributions in computational nanodosimetry2025-07-12T13:40:16ZIn computational nanodosimetry, Monte Carlo Track Structure (MCTS) simulations are employed to calculate ionisation cluster size distributions (ICSDs), which are crucial for characterising mixed radiation fields at the nanoscale. The Uniform Sampling (US) algorithm, commonly used for this purpose, is inefficient when evaluating ICSDs conditioned on clusters exceeding a given size $ν$ threshold. This study investigates a more efficient alternative - the Associated Volume (AV) algorithm - against the US approach for computing conditional ICSDs ($ν\ge 1$) from proton tracks simulated with Geant4-DNA. Two configurations of the AV algorithm were evaluated: the standard AV-Overlap, allowing sensitive volumes to overlap (with a 1/$ν$ correction), and the novel AV-No Overlap, which prevents overlap. We compared the conditional ICSDs, mean cluster size ($M_1$), complementary cumulative frequencies ($F_k$ for $k \in [2,7]$), and overall execution time per run and per event. Deviations exceeding two standard deviations of the mean difference were considered statistically significant. Although statistically significant differences in ICSDs, $M_1$ and $F_k$ were observed, the relative differences in the AV-Overlap rarely exceeded 5%, whereas the No Overlap configuration they ranged from $\lt$ 1% to approximately 15% at the higher $F_k$. Both AV configurations achieved execution times one to two orders of magnitude shorter than the US algorithm. Our findings indicate that the AV-Overlap algorithm may be a preferred alternative for calculating conditional ICSDs and derived nanodosimetric quantities, offering a substantial gain in computational efficiency without compromising accuracy.2024-06-06T20:39:44Z14 pages, 5 figuresJoão F. CanhotoYann PerrotReinhard SchulteAna BelchiorCarmen Villagrasahttp://arxiv.org/abs/2412.07006v3Correlation-weighted 23Na magnetic resonance fingerprinting in the brain2025-07-11T21:02:21ZWe developed a new sodium magnetic resonance fingerprinting ($^\text{23}\text{Na}$ MRF) method for the simultaneous mapping of $\text{T}_\text{1}$, $\text{T}_\text{2,long}^{*}$, $\text{T}_\text{2,short}^{*}$ and sodium density with built-in $Δ\text{B}_{1}^{+}$ (radiofrequency transmission inhomogeneities) and $Δ\text{f}_\text{0}$ corrections (frequency offsets). We based our $^\text{23}\text{Na}$ MRF implementation on a 3D FLORET sequence with 23 radiofrequency pulses. To capture the complex spin ${\frac{\text{3}}{\text{2}}}$ dynamics of the $^\text{23}\text{Na}$ nucleus, the fingerprint dictionary was simulated using the irreducible spherical tensor operators formalism. The dictionary contained 831,512 entries covering a wide range of $\text{T}_\text{1}$, $\text{T}_\text{2,long}^{*}$, $\text{T}_\text{2,short}^{*}$, $Δ\text{B}_\text{1}^{+}$ factor and $Δ\text{f}_\text{0}$ parameters. Fingerprint matching was performed using the Pearson correlation and the resulting relaxation maps were weighted with a subset of the highest correlation coefficients corresponding to signal matches for each voxel. Our $^\text{23}\text{Na}$ MRF method was compared against reference methods in a 7-compartment phantom, and applied in brain in five healthy volunteers at 7 T. In phantoms, $^\text{23}\text{Na}$ MRF produced values comparable to those obtained with reference methods. Average sodium relaxation time values in cerebrospinal fluid, gray matter and white matter across five healthy volunteers were in good agreement with values previously reported in the literature.2024-12-09T21:28:18ZLauren F. O'DonnellGonzalo G. RodriguezGregory LemberskiyZidan YuOlga DergachyovaMartijn CloosGuillaume Madelinhttp://arxiv.org/abs/2507.05312v2Introducing Image-Space Preconditioning in the Variational Formulation of MRI Reconstructions2025-07-11T15:48:55ZThe aim of the present article is to enrich the comprehension of iterative magnetic resonance imaging (MRI) reconstructions, including compressed sensing (CS) and iterative deep learning (DL) reconstructions, by describing them in the general framework of finite-dimensional inner-product spaces. In particular, we show that image-space preconditioning (ISP) and data-space preconditioning (DSP) can be formulated as non-conventional inner-products. The main gain of our reformulation is an embedding of ISP in the variational formulation of the MRI reconstruction problem (in an algorithm-independent way) which allows in principle to naturally and systematically propagate ISP in all iterative reconstructions, including many iterative DL and CS reconstructions where preconditioning is lacking. The way in which we apply linear algebraic tools to MRI reconstructions as presented in this article is a novelty.
A secondary aim of our article is to offer a certain didactic material to scientists who are new in the field of MRI reconstruction. Since we explore here some mathematical concepts of reconstruction, we take that opportunity to recall some principles that may be understood for experts, but which may be hard to find in the literature for beginners. In fact, the description of many mathematical tools of MRI reconstruction is fragmented in the literature or sometimes missing because considered as a general knowledge. Further, some of those concepts can be found in mathematic manuals, but not in a form that is oriented toward MRI. For example, we think of the conjugate gradient descent, the notion of derivative with respect to non-conventional inner products, or simply the notion of adjoint. The authors believe therefore that it is beneficial for their field of research to dedicate some space to such a didactic material.2025-07-07T11:01:25Z48 pages, 7 figures, 3 latex graphicsBastien MilaniJean-Baptist LedouxBerk Can AcikgozXavier Richardhttp://arxiv.org/abs/2507.08688v1Rapid MRI-Based Synthetic CT Simulations for Precise tFUS Targeting2025-07-11T15:38:19ZAccurate targeting is critical for the effectiveness of transcranial focused ultrasound (tFUS) neuromodulation. While CT provides accurate skull acoustic properties, its ionizing radiation and poor soft tissue contrast limit clinical applicability. In contrast, MRI offers superior neuroanatomical visualization without radiation exposure but lacks skull property mapping. This study proposes a novel, fully CT free simulation framework that integrates MRI-derived synthetic CT (sCT) with efficient modeling techniques for rapid and precise tFUS targeting. We trained a deep-learning model to generate sCT from T1-weighted MRI and integrated it with both full-wave (k-Wave) and accelerated simulation methods, hybrid angular spectrum (kWASM) and Rayleigh-Sommerfeld ASM (RSASM). Across five skull models, both full-wave and hybrid pipelines using sCT demonstrated sub-millimeter targeting deviation, focal shape consistency (FWHM ~3.3-3.8 mm), and <0.2 normalized pressure error compared to CT-based gold standard. Notably, the kW-ASM and RS-ASM pipelines reduced simulation time from ~3320 s to 187 s and 34 s respectively, achieving ~94% and ~90% time savings. These results confirm that MRI-derived sCT combined with innovative rapid simulation techniques enables fast, accurate, and radiation-free tFUS planning, supporting its feasibility for scalable clinical applications.2025-07-11T15:38:19ZHengyu GaoShaodong DingZiyang LiuJiefu ZhangBolun LiZhiwu AnLi WangJing JingTao LiuYubo FanZhongtao Huhttp://arxiv.org/abs/2507.08497v1Refraction corrected specular beamforming applied to cortical bone enhances interface visibility of bone-soft tissues interfaces2025-07-11T11:19:35ZUltrasound imaging of the cortex of long bones may enable the measurement of the cortical thickness and the ultrasound wave speed in cortical bone tissue. However, with bone loss, the cortical porosity and the size of the pores increase, resulting in strong ultrasound diffuse scattering whose magnitude can exceed that of the specular reflection from the bone-marrow (endosteal) interface. In this study we adapt to bone a specular beamforming technique proposed to better image a needle in soft tissue. Our approach takes into account both wave refraction and specular reflection physics to enhance the contrast of bone surfaces and reduce speckle from intracortical pores. In vivo ultrasound data were acquired at the center of the human tibia in a plane normal to the bone axis of 11 young healthy volunteeers. Ex vivo ultrasound data were acquired from 16 regions of interest from the femoral diaphysis of three elderly donors (donors 66-98 y.o.) using a 2.5 MHz US transducer. A single-element trans mission synthetic aperture imaging sequence was implemented on a research ultrasound system with a 2.5MHz phased array transducer. Image reconstruction was performed: (A) a delay-and-sum (DAS) algorithm with optimized f-number, correction of refraction at the soft tissue-bone interface and subject-specific ultrasound wave speed and (B) an adaptive algorithm using Snells law of reflection. The improvement of image quality was evaluated with contrast ratios of the average intensities: CEI between the endosteal surface and the center of the cortex. In vivo, specular beamforming improved the visibility of the endosteum (CEI ) by 1 to 13 dB while maintaining the relative contrast between the outer and inner surfaces of the cortex. These results suggest that the visualization of the intra-osseous anatomy can be enhanced if Snells law and wave refraction are taken into account during image reconstruction.2025-07-11T11:19:35ZAmadou S. DiaQuentin GrimalGuillaume Renaudhttp://arxiv.org/abs/2412.15869v2A Digital Phantom for MR Spectroscopy Data Simulation2025-07-10T14:11:16ZSimulated data is increasingly valued by researchers for validating MRS processing and analysis algorithms. However, there is no consensus on the optimal approaches for simulation models and parameters. This study introduces a novel MRS digital brain phantom framework, providing a comprehensive and modular foundation for MRS data simulation. The framework generates a digital brain phantom by combining anatomical and tissue label information with metabolite data from the literature. This phantom contains all necessary information for simulating spectral data. The MRS phantom is combined with a signal-based model to demonstrate its functionality and usability in generating various spectral datasets. Outputs can be saved in the NIfTI-MRS format, enabling their use in downstream applications. To evaluate the realism of the simulated spectra, a comparison was performed against in-vivo MRS data acquired under similar conditions. The phantom was implemented using two anatomical templates at different resolutions and tested across a range of user-defined simulation parameters. Simulated spectra exhibited realistic signal characteristics and structural variability. When compared to in-vivo data, the simulated spectra closely matched in terms of spectral shape, signal-to-noise ratio, and metabolite quantification. The simulations also captured key variability features and provided additional diversity not present in the in-vivo dataset, supporting use in robustness testing and data augmentation. This novel digital phantom provides a flexible and extensible platform for MRS data simulation. Its modular architecture, user-friendly GUI, and open-source implementation support reproducible research, algorithm development, and validation in the MRS community.2024-12-20T13:14:18Z8 figures, 3 tables, submitted to Magnetic Resonance in MedicineD. M. J. van de SandeA. T. GudmundsonS. Murali-ManoharC. W. Davies-JenkinsD. SimicicG. Simegnİ. ÖzdemirS. AmirrajabJ. P. MerkoferH. J. ZöllnerG. OeltzschnerR. A. E. Eddenhttp://arxiv.org/abs/2507.07459v1Subject grounding to reduce electromagnetic interference for MRI scanners operating in unshielded environments2025-07-10T06:20:19ZPurpose. Portable low-field (< 0.1 T) MRI is increasingly used for point-of-care imaging, but electromagnetic interference (EMI) presents a significant challenge, especially in unshielded environments. EMI can degrade image quality and compromise diagnostic utility. This study investigates whether subject grounding can effectively reduce EMI and improve image quality, comparing different grounding strategies. Methods. Experiments were conducted using a 47 mT Halbach-based MRI scanner with a single receive channel. Reproducibility was evaluated at a second site using a 72 mT scanner with similar geometry. Turbo spin echo sequences were used to image the hand and brain. Subject grounding was implemented using conductive cloth sleeves or ECG electrodes, each connected between the subject's skin and scanner ground. Three EMI conditions were tested: ambient, added single-frequency EMI, and broadband EMI. Signal-to-noise ratios (SNR) were calculated under each configuration. Results. Subject grounding significantly reduced EMI in both hand and brain scans. In hand imaging, conductive sleeves reduced noise from 85x to 1.25x the 50-ohm noise floor. In brain imaging, grounding alone reduced noise from 55x to 25x baseline; when combined with arc RF shields, noise was further reduced to 1.2x baseline, even under added EMI. These results were reproducible across different scanners and locations. Conclusion. Subject grounding is a simple, effective, and reproducible strategy for mitigating EMI in portable low-field MRI. It is especially effective for hand imaging, while brain imaging benefits from additional RF shielding. The approach is robust under various EMI conditions and may complement other denoising techniques.2025-07-10T06:20:19Z12 pages (+ 2 SI), 4 figures (+ 1 SI). Comments welcomeBeatrice LenaBart de VosTeresa Guallart-NavalJavad ParsaPablo García CristóbalRuben van den BroekChloé NajacJoseba AlonsoAndrew Webbhttp://arxiv.org/abs/2412.04639v2Multi-dynamic deep image prior for cardiac MRI2025-07-09T20:11:37ZCardiovascular magnetic resonance imaging is a powerful diagnostic tool for assessing cardiac structure and function. However, traditional breath-held imaging protocols pose challenges for patients with arrhythmias or limited breath-holding capacity. This work aims to overcome these limitations by developing a reconstruction framework that enables high-quality imaging in free-breathing conditions for various dynamic cardiac MRI protocols. Multi-Dynamic Deep Image Prior (M-DIP), a novel unsupervised reconstruction framework for accelerated real-time cardiac MRI, is introduced. To capture contrast or content variation, M-DIP first employs a spatial dictionary to synthesize a time-dependent intermediate image. Then, this intermediate image is further refined using time-dependent deformation fields that model cardiac and respiratory motion. Unlike prior DIP-based methods, M-DIP simultaneously captures physiological motion and frame-to-frame content variations, making it applicable to a wide range of dynamic applications. We validate M-DIP using simulated MRXCAT cine phantom data as well as free-breathing real-time cine, single-shot late gadolinium enhancement (LGE), and first-pass perfusion data from clinical patients. Comparative analyses against state-of-the-art supervised and unsupervised approaches demonstrate M-DIP's performance and versatility. M-DIP achieved better image quality metrics on phantom data, higher reader scores on in-vivo cine and LGE data, and comparable scores on in-vivo perfusion data relative to another DIP-based approach. M-DIP enables high-quality reconstructions of real-time free-breathing cardiac MRI without requiring external training data. Its ability to model physiological motion and content variations makes it a promising approach for various dynamic imaging applications.2024-12-05T22:15:18ZMarc VornehmChong ChenMuhammad Ahmad SultanSyed Murtaza ArshadYuchi HanFlorian KnollRizwan Ahmadhttp://arxiv.org/abs/2409.08635v2SynthAorta: A 3D Mesh Dataset of Parametrized Physiological Healthy Aortas2025-07-09T18:54:08ZThe effects of the aortic geometry on its mechanics and blood flow, and subsequently on aortic pathologies, remain largely unexplored. The main obstacle lies in obtaining patient-specific aorta models, an extremely difficult procedure in terms of ethics and availability, segmentation, mesh generation, and all of the accompanying processes. Contrastingly, idealized models are easy to build but do not faithfully represent patient-specific variability. Additionally, a unified aortic parametrization in clinic and engineering has not yet been achieved. To bridge this gap, we introduce a new set of statistical parameters to generate synthetic models of the aorta. The parameters possess geometric significance and fall within physiological ranges, effectively bridging the disciplines of clinical medicine and engineering. Smoothly blended realistic representations are recovered with convolution surfaces. These enable high-quality visualization and biological appearance, whereas the structured mesh generation paves the way for numerical simulations. The only requirement of the approach is one patient-specific aorta model and the statistical data for parameter values obtained from the literature. The output of this work is SynthAorta, a dataset of ready-to-use synthetic, physiological aorta models, each containing a centerline, surface representation, and a structured hexahedral finite element mesh. The meshes are structured and fully consistent between different cases, making them imminently suitable for reduced order modeling and machine learning approaches.2024-09-13T08:41:45ZDomagoj BošnjakGian Marco MelitoRichard SchussnigKatrin EllermannThomas-Peter Fries10.1109/TMI.2025.3599937http://arxiv.org/abs/2507.07010v1Robust Containerization of the High Angular Resolution Functional Imaging (HARFI) Pipeline2025-07-09T16:40:27ZHistorically, functional magnetic resonance imaging (fMRI) of the brain has focused primarily on gray matter, particularly the cortical gray matter and associated nuclei. However, recent work has demonstrated that functional activity in white matter also plays a meaningful role in both cognition and learning. In previous work, we introduced the High Angular Resolution Functional Imaging (HARFI) pipeline, which demonstrated both local and global patterns of functional correlation in white matter. Notably, HARFI enabled exploration of asymmetric voxel-wise correlation using odd-order spherical harmonics. Although the original implementation of HARFI was released via GitHub, adoption was limited due to the technical complexity of running the source code. In this work, we present a robust and efficient containerized version of the HARFI pipeline, enabling seamless execution across multiple public datasets. Our goal is to facilitate broader and deeper exploration of functional white matter architecture, especially through the lens of high angular resolution functional correlations. The key innovation of this work is the containerized implementation, which we have made available under a permissive open-source license to support reproducible and accessible research practices.2025-07-09T16:40:27ZZhiyuan LiKurt G. SchillingBennett A. Landmanhttp://arxiv.org/abs/2507.06966v1Segmentation Regularized Training for Multi-Domain Deep Learning Registration applied to MR-Guided Prostate Cancer Radiotherapy2025-07-09T15:55:32ZBackground: Accurate deformable image registration (DIR) is required for contour propagation and dose accumulation in MR-guided adaptive radiotherapy (MRgART). This study trained and evaluated a deep learning DIR method for domain invariant MR-MR registration. Methods: A progressively refined registration and segmentation (ProRSeg) method was trained with 262 pairs of 3T MR simulation scans from prostate cancer patients using weighted segmentation consistency loss. ProRSeg was tested on same- (58 pairs), cross- (72 1.5T MR Linac pairs), and mixed-domain (42 MRSim-MRL pairs) datasets for contour propagation accuracy of clinical target volume (CTV), bladder, and rectum. Dose accumulation was performed for 42 patients undergoing 5-fraction MRgART. Results: ProRSeg demonstrated generalization for bladder with similar Dice Similarity Coefficients across domains (0.88, 0.87, 0.86). For rectum and CTV, performance was domain-dependent with higher accuracy on cross-domain MRL dataset (DSCs 0.89) versus same-domain data. The model's strong cross-domain performance prompted us to study the feasibility of using it for dose accumulation. Dose accumulation showed 83.3% of patients met CTV coverage (D95 >= 40.0 Gy) and bladder sparing (D50 <= 20.0 Gy) constraints. All patients achieved minimum mean target dose (>40.4 Gy), but only 9.5% remained under upper limit (<42.0 Gy). Conclusions: ProRSeg showed reasonable multi-domain MR-MR registration performance for prostate cancer patients with preliminary feasibility for evaluating treatment compliance to clinical constraints.2025-07-09T15:55:32ZPreprint in preparation for submissionSudharsan MadhavanChengcheng GuiLando BosmaJosiah SimethJue JiangNicolas CoteNima Hassan RezaeianHimanshu NagarVictoria BrennanNeelam TyagiHarini Veeraraghavanhttp://arxiv.org/abs/2507.17764v1Diffusion-Assisted Frequency Attention Model for Whole-body Low-field MRI Reconstruction2025-07-09T12:30:06ZBy integrating the generative strengths of diffusion models with the representation capabilities of frequency-domain attention, DFAM effectively enhances reconstruction performance under low-SNR condi-tions. Experimental results demonstrate that DFAM consistently outperforms both conventional reconstruction algorithms and recent learning-based approaches. These findings highlight the potential of DFAM as a promising solution to advance low-field MRI reconstruction, particularly in resource-constrained or underdeveloped clinical settings.2025-07-09T12:30:06Z29 pages,7 figuresXin XieYu GuanZhuoxu CuiDong LiangQiegen Liuhttp://arxiv.org/abs/2507.06587v1Illuminating the Future: Nanophotonics for Future Green Technologies, Precision Healthcare, and Optical Computing2025-07-09T06:37:12ZNanophotonics, an interdisciplinary field merging nanotechnology and photonics, has enabled transformative advancements across diverse sectors including green energy, biomedicine, and optical computing. This review comprehensively examines recent progress in nanophotonic principles and applications, highlighting key innovations in material design, device engineering, and system integration. In renewable energy, nanophotonic allows light-trapping nanostructures and spectral control in perovskite solar cells, concentrating solar power, and thermophotovoltaics. That have significantly enhanced solar conversion efficiencies, approaching theoretical limits. For biosensing, nanophotonic platforms achieve unprecedented sensitivity in detecting biomolecules, pathogens, and pollutants, enabling real-time diagnostics and environmental monitoring. Medical applications leverage tailored light-matter interactions for precision photothermal therapy, image-guided surgery, and early disease detection. Furthermore, nanophotonics underpins next-generation optical neural networks and neuromorphic computing, offering ultra-fast, energy-efficient alternatives to von Neumann architectures. Despite rapid growth, challenges in scalability, fabrication costs, and material stability persist. Future advancements will rely on novel materials, AI-driven design optimization, and multidisciplinary approaches to enable scalable, low-cost deployment. This review summarizes recent progress and highlights future trends, including novel material systems, multidisciplinary approaches, and enhanced computational capabilities, to pave the way for transformative applications in this rapidly evolving field.2025-07-09T06:37:12ZOsama M. HalawaEsraa AhmedMalk M. AbdelrazekYasser M. NagyOmar A. M. Abdelraouf