https://arxiv.org/api/olDlf+xEkRNmWUujqHOPhByvUuk2026-06-26T17:51:06Z9008115515http://arxiv.org/abs/2412.10622v4A recent evaluation on the performance of LLMs on radiation oncology physics using questions of randomly shuffled options2025-07-18T23:41:43ZPurpose: We present an updated study evaluating the performance of large language models (LLMs) in answering radiation oncology physics questions, focusing on the recently released models.
Methods: A set of 100 multiple-choice radiation oncology physics questions, previously created by a well-experienced physicist, was used for this study. The answer options of the questions were randomly shuffled to create "new" exam sets. Five LLMs -- OpenAI o1-preview, GPT-4o, LLaMA 3.1 (405B), Gemini 1.5 Pro, and Claude 3.5 Sonnet -- with the versions released before September 30, 2024, were queried using these new exam sets. To evaluate their deductive reasoning ability, the correct answer options in the questions were replaced with "None of the above." Then, the explain-first and step-by-step instruction prompts were used to test if this strategy improved their reasoning ability. The performance of the LLMs was compared with the answers from medical physicists.
Results: All models demonstrated expert-level performance on these questions, with o1-preview even surpassing medical physicists with a majority vote. When replacing the correct answer options with 'None of the above', all models exhibited a considerable decline in performance, suggesting room for improvement. The explain-first and step-by-step instruction prompts helped enhance the reasoning ability of the LLaMA 3.1 (405B), Gemini 1.5 Pro, and Claude 3.5 Sonnet models.
Conclusion: These recently released LLMs demonstrated expert-level performance in answering radiation oncology physics questions, exhibiting great potential to assist in radiation oncology physics education and training.2024-12-14T00:05:42ZPeilong WangJason HolmesZhengliang LiuDequan ChenTianming LiuJiajian ShenWei Liu10.3389/fonc.2025.1557064http://arxiv.org/abs/2501.12249v4Solving Blind Inverse Problems: Adaptive Diffusion Models for Motion-corrected Sparse-view 4DCT2025-07-18T09:58:15ZFour-dimensional computed tomography (4DCT) is essential for medical imaging applications like radiotherapy, which demand precise respiratory motion representation. Traditional methods for reconstructing 4DCT data suffer from artifacts and noise, especially in sparse-view, low-dose contexts. Motion-corrected (MC) reconstruction is a blind inverse problem that we propose to solve with a novel diffusion model (DM) framework that calibrates an adaptive unknown forward model for motion correction. Furthermore, we used a wavelet diffusion model (WDM) to address computational cost and memory usage. By leveraging the prior probability distribution function (PDF) from the DMs, we enhance the joint reconstruction and motion estimation (JRM) process, improving image quality and preserving resolution. Experiments on extended cardiac-torso (XCAT) phantom data demonstrate that our method outperforms existing techniques, yielding artifact-free, high-resolution reconstructions even under irregular breathing conditions. These results showcase the potential of combining DMs with motion correction to advance sparse-view 4DCT imaging.2025-01-21T16:09:23Z4 pages, 2 figures, 1 tableAntoine De PaepeAlexandre BousseClémentine Phung-NgocDimitris Visvikishttp://arxiv.org/abs/2507.13754v1GPU Accelerated Transducer-Field Calculation using the Traditional Born Series Formulation for Realistic Media2025-07-18T08:59:19ZThis study numerically solves inhomogeneous Helmholtz equations modeling acoustic wave propagation in homogeneous and lossless, absorbing and dispersive, inhomogeneous and nonlinear media. The traditional Born series (TBS) method has been employed to solve such equations. The full wave solution in this methodology is expressed as an infinite sum of the solution of the unperturbed equation weighted by increasing power of the potential. Simulated pressure field patterns for a linear array of acoustic sources (a line source) estimated by the TBS procedure exhibit excellent agreement with that of a standard time domain approach (k-Wave toolbox). The TBS scheme though iterative but is a very fast method. For example, GPU enabled CUDA C code implementing the TBS procedure takes 5 s to calculate the pressure field for the homogeneous and lossless medium whereas nearly 500 s is taken by the later module. The execution time for the corresponding CPU code is about 20 s. The findings of this study demonstrate the effectiveness of the TBS method for solving inhomogeneous Helmholtz equation, while the GPU-based implementation significantly reduces the computation time. This method can be explored in practice for calculation of pressure fields generated by real transducers designed for diverse applications.2025-07-18T08:59:19ZUjjal MandalJagpreet SinghBen T CoxRatan K Sahahttp://arxiv.org/abs/2507.13653v1Coupled Modeling of External Pressure and Capillary Blood Flow: Nonlinear Dynamics of Vascular Elasticity and Collapse Effects2025-07-18T04:48:08ZExternal pressure significantly influences microcirculatory capillary blood flow, yet current studies lack quantitative modeling. This work proposes a nonlinear segmented coupling model between external pressure and capillary flow, incorporating vascular elasticity and collapse effects. The pressure-flow response is divided into three phases: elastic compression under low pressure (less than 30 mmHg), elliptical collapse in the transition zone (30 to 40 mmHg), and closure-induced attenuation under high pressure (above 40 mmHg), with explicit expressions derived for each. Parameter sensitivity analysis and comparison with literature demonstrate the model's capability in capturing key determinants. The proposed framework supports dose-response assessment and individualized parameter tuning in pressure-based therapies such as tourniquets and compression garments.2025-07-18T04:48:08ZXinyi CaiHanyue MoYuyao ChangKun Chenghttp://arxiv.org/abs/2507.13630v1Quantification of head and neck cancer patients' anatomical changes during radiotherapy: prediction of replanning need2025-07-18T03:41:57ZHead and neck cancer (HNC) patients who undergo radiotherapy (RT) may experience anatomical changes during treatment, compromising the validity of the initial treatment plan, necessitating replanning. However, replanning disrupts clinical workflows, creating a stressful environment. Currently, no standardized method exists to determine the total amount of anatomical change that necessitates replanning. This project aimed to create metrics to describe anatomical changes HNC patients may experience during RT and develop machine learning (ML) models to predict RT replanning. We included a cohort of 150 HNC patients treated at the McGill University Health Centre. Based on the shape of the RT structures, we created metrics and developed an extraction pipeline, called HNGeoNatomyX, to automatically calculate them. A univariate metric analysis using linear regression was conducted to obtain the rate of change of each metric. We also obtained the relative variation of each metric between the pre-treatment scan and the fraction at which replanning was requested. Fraction-specific ML models (models that incorporated information available up to and including the specific fraction) for fractions 5, 10, and 15 were built using the metrics, clinical data, and feature selection techniques. To estimate models' performance, we used a repeated stratified 5-fold cross-validation resampling technique and the Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) curve. The best specific multivariate models for fractions 5, 10, and 15 yielded testing scores of 0.82, 0.70, and 0.79, respectively. Our models early predicted replanning for 76% of the true positives. The created metrics have the potential to characterize and distinguish which patients will necessitate RT replanning. They show promise in guiding clinicians to evaluate RT replanning for HNC patients and streamline workflows.2025-07-18T03:41:57ZSubmitted to the Journal of Applied Clinical Medical PhysicsOdette Rios-IbacacheJames ManaladKayla O'Sullivan-StebenEmily PoonLuc GalarneauJulia KhriguianGeorge ShenoudaJohn Kildea10.1002/acm2.70465http://arxiv.org/abs/2507.09842v2GATE 10 Monte Carlo particle transport simulation -- Part I: development and new features2025-07-17T23:00:50ZWe present GATE version 10, a major evolution of the open-source Monte Carlo simulation application for medical physics, built on Geant4. This release marks a transformative evolution, featuring a modern Python-based user interface, enhanced multithreading and multiprocessing capabilities, the ability to be embedded as a library within other software, and a streamlined framework for collaborative development. In this Part 1 paper, we outline GATE's position among other Monte Carlo codes, the core principles driving this evolution, and the robust development cycle employed. We also detail the new features and improvements. Part 2 will detail the architectural innovations and technical challenges. By combining an open, collaborative framework with cutting-edge features, such a Monte Carlo platform supports a wide range of academic and industrial research, solidifying its role as a critical tool for innovation in medical physics.2025-07-14T00:41:06ZDavid SarrutNicolas ArborThomas BaudierJulien BertKonstantinos ChatzipapasMartina FavarettoHermann FuchsLoïc GrevillotHussein HarbGert Van HoeyMaxime JacquetSébastien JanYihan JiaGeorge C. KagadisHan Gyu KangPaul KleverOlga KochebinaWojciech KrzemienLydia MaignePhilipp MohrGuneet MummaneniValentina PanetaPanagiotis PapadimitroulasAlexis PeredaAxel RannouAndreas F. ReschEmilie RoncaliMaxime ToussaintCarlotta TrigilaCharalampos TsoumpasJing ZhangKarl ZiemonsNils Krahhttp://arxiv.org/abs/2507.09840v2GATE 10 Monte Carlo particle transport simulation -- Part II: architecture and innovations2025-07-17T22:49:13ZOver the past years, we have developed GATE version 10, a major re-implementation of the long-standing Geant4-based Monte Carlo application for particle and radiation transport simulation in medical physics. This release introduces many new features and significant improvements, most notably a Python-based user interface replacing the legacy static input files. The new functionality of GATE version 10 is described in the part 1 companion paper. The development brought significant challenges. In this paper, we present the solutions that we have developed to overcome these challenges. In particular, we present a modular design that robustly manages the core components of a simulation: particle sources, geometry, physics processes, and data acquisition. The architecture consists of parts written in C++ and Python, which needed to be coupled. We explain how this framework allows for the precise, time-aware generation of primary particles, a critical requirement for accurately modeling positron emission tomography (PET), radionuclide therapies, and prompt-gamma timing systems. We present how GATE 10 handles complex Geant4 physics settings while exposing a simple interface to the user. Furthermore, we describe the technical solutions that facilitate the seamless integration of advanced physics models and variance reduction techniques. The architecture supports sophisticated scoring of physical quantities (such as Linear Energy Transfer and Relative Biological Effectiveness) and is designed for multithreaded execution. The new user interface allows researchers to script complex simulation workflows and directly couple external tools, such as artificial intelligence models for source generation or detector response. By detailing these architectural innovations, we demonstrate how GATE 10 provides a more powerful and flexible tool for research and innovation in medical physics.2025-07-14T00:25:13ZNils KrahNicolas ArborThomas BaudierJulien BertKonstantinos ChatzipapasMartina FavarettoHermann FuchsLoïc GrevillotHussein HarbGert Van HoeyMaxime JacquetSébastien JanYihan JiaGeorge C. KagadisHan Gyu KangPaul KleverOlga KochebinaLydia MaignePhilipp MohrGuneet MummaneniValentina PanetaPanagiotis PapadimitroulasAlexis PeredaAxel RannouAndreas F. ReschEmilie RoncaliMaxime ToussaintCarlotta TrigilaCharalampos TsoumpasJing ZhangKarl ZiemonsDavid Sarruthttp://arxiv.org/abs/2506.06671v7An analytical model for gold nanoparticle radiosensitisation2025-07-16T15:38:55ZIn this paper, we derive a variance-driven Local-Effect-Model ($σ$-LEM) to predict radiosensitization due to gold nanoparticles (AuNP). Assuming that the number of Au photo-ionisations scales strictly with particle volume $V_{\mathrm{NP}}\propto R^{3}$, a linear relation between dose-enhancement ratio and concentration is achieved ($DER = 1 + K_c,c$), in which $K_c$ is a beam-quality and nucleus-size-specific term, and $c$ is the concentration in mM. Furthermore, assuming that the cascade energy deposition is log-normally distributed, the enhanced dose in each target voxel can be written as $D_{\text{enh}} = D_{0}\exp(σZ)$ with $Z \sim \mathcal{N}(0,1)$ and width $σ= \sqrt{2\ln(1+Kc)}$.
Assuming a linear-quadratic (LQ) dose response, a relation between cell survival and dose can be derived. Despite no closed form for the log-normal distribution, averaging over the entire domain using first- and second-order moments leads to three possible closed forms: variance-only, mixed-term, and second-order. These three variants adapt well to low-concentration, mid-concentration, and high-concentration regimes.
The model was tested for Bovine aortic endothelial cells (BAEC) results taken from a Local Effect Model (LEM) and experimental values. The model agrees within $\le 2.5%$ with the experimental and LEM data, but presents significant changes to the conceptual results obtained with the LEM, in particular indicating that AuNP dose enhancement is mostly $α$-driven, as posited previously by other authors. These findings are further developed in the manuscript.
The theoretical framework presented here collapses radiobiological outcomes to three experimentally controllable variables -- beam quality, nucleus size, and intracellular concentration $c$ -- while retaining mechanistic fidelity. Additional tests should be made to further confirm the validity of the model.2025-06-07T05:28:46ZAdded spatial resolutionPedro Teleshttp://arxiv.org/abs/2507.12134v1Novel multifunctional plasmonic fiber probe: Enabling plasmonic heating and SERS sensing for biomedical applications2025-07-16T11:04:49ZOptical fiber-based platforms are increasingly explored as compact, minimally invasive tools for integrated photonic functionalities in biomedical applications. Among these, the combination of plasmonic heating and optical sensing on a single fiber tip offers compelling opportunities for localized photothermal actuation and in situ molecular detection. In this work, we present a multifunctional plasmonic fiber probe (PFP) that enables spectral multiplexing of thermo-plasmonic heating and surface-enhanced Raman spectroscopy (SERS). This dual capability is achieved by integrating gold nanoislands (AuNIs) onto the flat facet of a multimode optical fiber using a solid-state dewetting process - a straightforward and scalable fabrication method that avoids the complexity of lithographic techniques. We characterize how the morphology of the AuNIs modulates optical extinction, photothermal response, and electromagnetic field enhancement across the visible and near-infrared spectrum. Specifically, we demonstrate efficient, wavelength-dependent heating under visible light and strong SERS signal enhancement under near-infrared excitation, both supported by electromagnetic and thermal simulations. The ability to decouple photothermal stimulation and Raman sensing in a single, fiber-integrated device addresses a current gap in lab-on-fiber technologies, where multifunctional operation is often constrained to a single wavelength.2025-07-16T11:04:49ZMuhammad Fayyaz KashifDi ZhengLinda PiscopoLiam CollardAntonio BalenaHuatian HuDaniele RiccioFrancesco TantussiFrancesco De AngelisMassimo de VittorioFerruccio Pisanellohttp://arxiv.org/abs/2507.11963v1Parallel-plate chambers as radiation-hard detectors for time-based beam diagnostics in carbon-ion radiotherapy2025-07-16T06:53:25ZAccurate range verification of carbon ion beams is critical for the precision and safety of charged particle radiotherapy. In this study, we evaluated the feasibility of using a parallel-plate ionization chamber for real-time, time-based diagnostic monitoring of carbon ion beams. The chamber featured a 0.4 mm gas gap defined by metallic electrodes and was filled with carbon dioxide (CO$_2$), a non-polymerizing gas suitable for high-rate applications. Timing precision was assessed via self-correlation analysis, yielding a precision approaching one picosecond for one-second acquisitions under clinically relevant beam conditions. This level of timing accuracy translates to a water-equivalent range uncertainty of approximately 1 mm, which meets the recommended clinical tolerance for carbon ion therapy. Furthermore, the kinetic energy of the beam at the synchrotron extraction point was determined from the measured orbital period, with results consistently within 1 MeV/nucleon of the nominal energy. These findings demonstrate the potential of parallel-plate chambers for precise, real-time energy and range verification in clinical carbon ion beam quality assurance.2025-07-16T06:53:25Z14 pages, 10 figures, 2 tables. Submitted to Nucl. Instrum. Methods Phys. Res. ANa Hye KwonSung Woon ChoiSoo Rim HanYongdo YunMin Cheol HanChae-Seon HongHo Jin KimHo LeeChanghwan KimDo Won KimWoong Sub KoomJin Sung KimN. CarolinoL. LopesDong Wook KimPaulo J. R. Fontehttp://arxiv.org/abs/2507.06273v2Magneto-radiative modelling and artificial neural network optimization of biofluid flow in a stenosed arterial domain2025-07-16T06:41:32ZThe increasing complexity of cardiovascular diseases and limitations in traditional healing methods mandate the invention of new drug delivery systems that assure targeted, effective, and regulated treatments, contributing directly to UN SDGs 3 and 9, thereby encouraging the utilization of sustainable medical technologies in healthcare. This study investigates the flow of a Casson-Maxwell nanofluid through a stenosed arterial domain. The quantities, such as skin friction and heat transfer rate, are analysed in detail. The Casson-Maxwell fluid shows a lower velocity profile than the Casson fluids, which indicates the improved residence time for efficient drug delivery. The heat transfer rate shows an increase with higher volume fractions of copper and aluminium oxide nanoparticles and a decrease with higher volume fractions of silver nanoparticles. The skin friction coefficient decreases by 219% with a unit increase in the Maxwell parameter, whereas it increases by 66.1% with a unit rise in the Casson parameter. This work supports SDGs 4 and 17 by fostering interdisciplinary learning and collaboration in fluid dynamics and healthcare innovation. Additionally, the rate of heat flow was forecasted (with an overall R-value of 0.99457) using the Levenberg-Marquardt backpropagation training scheme under the influence of magneto-radiative, linear heat source and Casson-Maxwell parameters along with the tri-metallic nanoparticle volume fractions. It is also observed that the drag coefficient is most sensitive to the changes in the Maxwell parameter.2025-07-08T08:04:40ZS P ShivakumarGunisetty RamasekharP NimmySujesh AreekaraL ThanujaT V SmithaS DevanathanGanesh R NaikK V Nagarajahttp://arxiv.org/abs/2507.12491v1Multi-objective CFD optimization of an intermediate diffuser stage for PediaFlow pediatric ventricular assist device2025-07-15T20:13:52ZBackground: Computational fluid dynamics (CFD) has become an essential design tool for ventricular assist devices (VADs), where the goal of maximizing performance often conflicts with biocompatibility. This tradeoff becomes even more pronounced in pediatric applications due to the stringent size constraints imposed by the smaller patient population. This study presents an automated CFD-driven shape optimization of a new intermediate diffuser stage for the PediaFlow pediatric VAD, positioned immediately downstream of the impeller to improve pressure recovery.
Methods: We adopted a multi-objective optimization approach to maximize pressure recovery while minimizing hemolysis. The proposed diffuser stage was isolated from the rest of the flow domain, enabling efficient evaluation of over 450 design variants using Sobol sequence, which yielded a Pareto front of non-dominated solutions. The selected best candidate was further refined using local T-search algorithm. We then incorporated the optimized front diffuser into the full pump for CFD verification and in vitro validation.
Results: We identified critical dependencies where longer blades increased pressure recovery but also hemolysis, while the wrap angle showed a strong parabolic relationship with pressure recovery but a monotonic relationship with hemolysis. Counterintuitively, configurations with fewer blades (2-3) consistently outperformed those with more blades (4-5) in both metrics. The optimized two-blade design enabled operation at lower pump speeds (14,000 vs 16,000 RPM), improving hydraulic efficiency from 26.3% to 32.5% and reducing hemolysis by 31%.
Conclusion: This approach demonstrates that multi-objective CFD optimization can systematically explore complex design spaces while balancing competing priorities of performance and hemocompatibility for pediatric VADs.2025-07-15T20:13:52ZMansur ZhussupbekovJingChun WuGreg W BurgreenScott StelickJeongho KimJames F Antaki10.1111/aor.70004http://arxiv.org/abs/2507.11329v1Quantitative multi-metabolite imaging of Parkinson's disease using AI boosted molecular MRI2025-07-15T14:01:54ZTraditional approaches for molecular imaging of Parkinson's disease (PD) in vivo require radioactive isotopes, lengthy scan times, or deliver only low spatial resolution. Recent advances in saturation transfer-based PD magnetic resonance imaging (MRI) have provided biochemical insights, although the image contrast is semi-quantitative and nonspecific. Here, we combined a rapid molecular MRI acquisition paradigm with deep learning based reconstruction for multi-metabolite quantification of glutamate, mobile proteins, semisolid, and mobile macromolecules in an acute MPTP (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) mouse model. The quantitative parameter maps are in general agreement with the histology and MR spectroscopy, and demonstrate that semisolid magnetization transfer (MT), amide, and aliphatic relayed nuclear Overhauser effect (rNOE) proton volume fractions may serve as PD biomarkers.2025-07-15T14:01:54ZThis project was funded by the European Union (ERC, BabyMagnet, project no. 101115639). Views and opinions expressed are, however, those of the authors only and do not necessarily reflect those of the European Union or the European Research Council. Neither the European Union nor the granting authority can be held responsible for themnpj Imaging 3, 66 (2025)Hagar ShmuelySchool of Biomedical Engineering, Tel Aviv University, Tel Aviv, IsraelMichal RivlinSchool of Biomedical Engineering, Tel Aviv University, Tel Aviv, IsraelOr PerlmanSchool of Biomedical Engineering, Tel Aviv University, Tel Aviv, IsraelSagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel10.1038/s44303-025-00130-xhttp://arxiv.org/abs/2503.12904v2Shoot-through layers in upright proton arcs unlock advantages in plan quality and range verification2025-07-15T12:31:25ZBackground: Upright proton therapy with compact delivery systems has the potential to reduce costs for treatments but could also lead to broadening of the beam penumbra due to energy selection close to the patient. Purpose: This study aims at combining upright static proton arcs with additional layers of shoot-through (ST) protons to sharpen the beam penumbra and improve plan quality for such systems. Methods: We examined various treatment plans for a virtual phantom: 3-beam IMPT, static arc (Arc) with/without ST (Arc+ST), and with/without collimation (+Coll). In the virtual phantom three different targets were utilized to study the effect on conformity index (CI), homogeneity index (HI), robustness and mean dose to the phantom volume. The phantom study was complemented with a head-and-neck (H&N) patient case with a similar set of plans. The delivery time for all plans was estimated. A range verification concept that determines residual ranges of the ST protons was studied in simulated scenarios for the H&N case. Results: In the phantom study, the Arc+ST plans show superior CI, HI and target robustness compared to the Arc+Coll plans. For the Arc plans without ST, the collimated plans perform better than the uncollimated plans. On the other hand, for Arc+ST, collimation has little impact on CI, HI and robustness. For the H&N case, similar improvements for Arc+ST can be seen. These results imply that no aperture is needed when combining arcs with ST, which in turn substantially reduces treatment times. The range verification simulation shows that the method is sensitive to detect SPR errors, setup errors and changes in the patient anatomy. Conclusions: Combining proton arcs and ST layers can enhance compact upright proton solutions by improving plan quality. It is also tailored for the inclusion of a fast and straightforward residual range verification method.2025-03-17T08:10:32Z22 pages, 9 figuresMed Phys. 2025; 52:e18051Erik EngwallVictor MikhalevJohan SundströmOtte MarthinViktor Wase10.1002/mp.18051http://arxiv.org/abs/2507.08189v2Robust Semi-Supervised CT Radiomics for Lung Cancer Prognosis: Cost-Effective Learning with Limited Labels and SHAP Interpretation2025-07-15T01:10:47ZBackground: CT imaging is vital for lung cancer management, offering detailed visualization for AI-based prognosis. However, supervised learning SL models require large labeled datasets, limiting their real-world application in settings with scarce annotations.
Methods: We analyzed CT scans from 977 patients across 12 datasets extracting 1218 radiomics features using Laplacian of Gaussian and wavelet filters via PyRadiomics Dimensionality reduction was applied with 56 feature selection and extraction algorithms and 27 classifiers were benchmarked A semi supervised learning SSL framework with pseudo labeling utilized 478 unlabeled and 499 labeled cases Model sensitivity was tested in three scenarios varying labeled data in SL increasing unlabeled data in SSL and scaling both from 10 percent to 100 percent SHAP analysis was used to interpret predictions Cross validation and external testing in two cohorts were performed.
Results: SSL outperformed SL, improving overall survival prediction by up to 17 percent. The top SSL model, Random Forest plus XGBoost classifier, achieved 0.90 accuracy in cross-validation and 0.88 externally. SHAP analysis revealed enhanced feature discriminability in both SSL and SL, especially for Class 1 survival greater than 4 years. SSL showed strong performance with only 10 percent labeled data, with more stable results compared to SL and lower variance across external testing, highlighting SSL's robustness and cost effectiveness.
Conclusion: We introduced a cost-effective, stable, and interpretable SSL framework for CT-based survival prediction in lung cancer, improving performance, generalizability, and clinical readiness by integrating SHAP explainability and leveraging unlabeled data.2025-07-10T21:57:15Z12 pages, 4 figuresMohammad R. SalmanpourAmir Hossein PouriaSonia FalahatiShahram TaebSomayeh Sadat MehrniaMehdi MaghsudiAli Fathi JouzdaniMehrdad OveisiIlker HacihalilogluArman Rahmim