https://arxiv.org/api/6zIxT9QGcMSPeADb9g8y+xVJ7GE 2026-06-26T14:29:39Z 9008 1110 15 http://arxiv.org/abs/2508.01083v1 R-Index: A Robust Metric for IVIM Parameter Estimation on Clinical MRI Scanners 2025-08-01T21:37:13Z Background: Intravoxel Incoherent Motion (IVIM) model characterizes both water diffusion and perfusion in tissues, providing quantitative biomarkers valuable for tumor tissue characterization. However, parameter estimation based on this model is challenging due to its ill-posed nature, resulting in poor reproducibility, particularly at low signal to noise ratios (SNRs) in a clinic scenario. Purpose: This study analyzes the uncertainty of IVIM model fitting, quantifies parameter collinearity, and introduces a new index with enhanced robustness to enhance clinical applicability of the IVIM model. Study Type: Prospective. Population: One healthy volunteer. Field Strength/Sequence: 1.5T; single-shot EPI DWI. Assessment: The probability distributions of estimated IVIM parameters were evaluated across a clinically relevant range. Collinearity among parameters was assessed and a new metric, the R-index, was proposed. The R-index linearly combines individual IVIM parameters to mitigate collinearity and reduce estimation uncertainty. Simulation and a volunteer study was conducted to validate the presence of parameter collinearity and to assess the robustness of the R-index. Statistical Tests: N/A Results: In simulation studies with a typical clinical setting (SNR = 20), normalized IVIM parameters exhibited mean standard deviations ranging from 0.107 to 0.269, while the R-index showed a reduced deviation of 0.064. Repeated scans in a healthy volunteer confirmed the presence of parameter collinearity, with 32% of voxels exhibiting statistically significant correlations (p < 0.05) among fitted IVIM parameters, and a mean Pearson correlation coefficient of r = -0.96. Data Conclusion: The R-index provides a robust metric for IVIM model fitting under low SNR conditions typical of clinical MRI, offering improved reproducibility and potential for broader clinical applicability. 2025-08-01T21:37:13Z Yan Dai Xun Jia Yen-peng Liao Jie Deng http://arxiv.org/abs/2508.01050v1 Pointwise Encoding Time reduction with Radial Acquisition (PETRA) to pseudo-CT mapping for precision Focused Transcranial Ultrasound Applications 2025-08-01T20:08:22Z Ultrasound simulations used for treatment planning in transcranial ultrasound stimulation(TUS) currently depend on converting computed tomography(CT) images to acoustic properties. Aiming to reduce subject exposure to ionising radiation, recent literature focused on generating pseudo-CT images from different magnetic resonance(MR) imaging sequences. Here, the PETRA (pointwise encoding time reduction with radial acquisition) sequence was used because of its stronger ability to image bones. A dataset of paired CT and PETRA scans was acquired separately for human subjects and ex-vivo skulls. Principal component analysis performed on all bone voxels uncovered the affine relationship converting PETRA images to pseudo-CTs. Acoustic simulations based on CTs and pseudo-CTs were performed in k-Plan and k-wave. For in-vivo data, the mean absolute errors in focal position, peak pressure and focal volume were $0.48\pm0.25$mm, $5.1\pm4.0\%$ and $5.8\pm4.4\%$. The similarity of acoustic fields from ex-vivo CTs/pseudo-CTs was compared with experimental data. The corresponding errors were $1.5\pm1.2$mm, $17.1\pm14.6\%$ and $32.5\pm22.5\%$ for CT and $1.6\pm1.4$mm, $18.2\pm17.1\%$ and $19.2\pm15.9\%$ for pseudo-CT. The small errors for in-vivo data and the similarity of the experimental errors for both methods validate the use of PETRA-derived pseudo-CT as an alternative to CT, ensuring precise acoustic field predictions. The conversion tool is available at https://github.com/ucl-bug/petra-to-ct. 2025-08-01T20:08:22Z Maria Miscouridou Alisa A. Krokhmal Aaron T. Hess Jon Campbell Charlotte J. Stagg Eleanor Martin Bradley E. Treeby http://arxiv.org/abs/2508.00651v1 Review: Adaptive Radiation Therapy for Head and Neck Cancer 2025-08-01T14:12:43Z The future of ART in head and neck cancer is just beginning. Novel technologies have pushed the boundary of what is possible in terms of techniques to identify biomarkers for adaptation as well as innovative devices specialized to respond to these adaptations, sometimes in real-time. Important interdisciplinary steps must be taken moving forward to ensure the safe deployment of these new techniques, such as rigorous quality assurance evaluations from medical physicists, clinical trials from physicians, and comprehensive testing from vendors prior to release. In summary, we aimed not to provide a single correct answer for the optimal implementation of ART in the era of imaging biomarkers, but to encourage the field to collaborate and bring each idea discussed here together to overcome current barriers and deliver the best treatment possible to the patient. 2025-08-01T14:12:43Z Lucas McCullum Sonali J. Joshi Brandon M. Godinich Parshawn Gerafian Rishabh Gaur Qusai Alakayleh Ergys Subashi Renjie He Samuel L. Mulder Zaphanlene Kaffey Grace Murley Natalie A. West Saleh Ramezani Cem Dede Laia Humbert-Vidan Clifton D. Fuller http://arxiv.org/abs/2508.00640v1 Anatomically Informed GREIT Reconstruction: Improving EIT Imaging for Lung Monitoring 2025-08-01T13:55:14Z Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient's thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. Anatomical features from CT data were included by customizing background conductivity and GREIT training target distribution. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Integrating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients. 2025-08-01T13:55:14Z Physiological Measurement, Vol. 47, 2026 Maximilian Ludwig Carolin M. Eichinger Armin Sablewski Inéz Frerichs Tobias Becher Wolfgang A. Wall 10.1088/1361-6579/ae4289 http://arxiv.org/abs/2507.23579v1 Impact of a Lower Limb Exosuit Anchor Points on Energetics and Biomechanics 2025-07-31T14:08:25Z Anchor point placement is a crucial yet often overlooked aspect of exosuit design since it determines how forces interact with the human body. This work analyzes the impact of different anchor point positions on gait kinematics, muscular activation and energetic consumption. A total of six experiments were conducted with 11 subjects wearing the XoSoft exosuit, which assists hip flexion in five configurations. Subjects were instrumented with an IMU-based motion tracking system, EMG sensors, and a mask to measure metabolic consumption. The results show that positioning the knee anchor point on the posterior side while keeping the hip anchor on the anterior part can reduce muscle activation in the hip flexors by up to 10.21\% and metabolic expenditure by up to 18.45\%. Even if the only assisted joint was the hip, all the configurations introduced changes also in the knee and ankle kinematics. Overall, no single configuration was optimal across all subjects, suggesting that a personalized approach is necessary to transmit the assistance forces optimally. These findings emphasize that anchor point position does indeed have a significant impact on exoskeleton effectiveness and efficiency. However, these optimal positions are subject-specific to the exosuit design, and there is a strong need for future work to tailor musculoskeletal models to individual characteristics and validate these results in clinical populations. 2025-07-31T14:08:25Z 12 pages, 10 figures IEEE Trans. Biomed. Eng. (2025) Chiara Lambranzi Giulia Oberti Christian Di Natali Darwin G. Caldwell Manuela Galli Elena De Momi Jesùs Ortiz 10.1109/TBME.2025.3593040 http://arxiv.org/abs/2412.13811v2 A Lightweight Optimization Framework for Estimating 3D Brain Tumor Infiltration 2025-07-31T11:05:48Z Glioblastoma, the most aggressive primary brain tumor, poses a severe clinical challenge due to its diffuse microscopic infiltration, which remains largely undetected on standard MRI. As a result, current radiotherapy planning employs a uniform 15 mm margin around the resection cavity, failing to capture patient-specific tumor spread. Tumor growth modeling offers a promising approach to reveal this hidden infiltration. However, methods based on partial differential equations or physics-informed neural networks tend to be computationally intensive or overly constrained, limiting their clinical adaptability to individual patients. In this work, we propose a lightweight, rapid, and robust optimization framework that estimates the 3D tumor concentration by fitting it to MRI tumor segmentations while enforcing a smooth concentration landscape. This approach achieves superior tumor recurrence prediction on 192 brain tumor patients across two public datasets, outperforming state-of-the-art baselines while reducing runtime from 30 minutes to less than one minute. Furthermore, we demonstrate the framework's versatility and adaptability by showing its ability to seamlessly integrate additional imaging modalities or physical constraints. 2024-12-18T12:58:38Z Jonas Weidner Michal Balcerak Ivan Ezhov André Datchev Laurin Lux Lucas Zimmer Daniel Rueckert Björn Menze Benedikt Wiestler http://arxiv.org/abs/2507.23129v1 MRpro - open PyTorch-based MR reconstruction and processing package 2025-07-30T22:15:24Z We introduce MRpro, an open-source image reconstruction package built upon PyTorch and open data formats. The framework comprises three main areas. First, it provides unified data structures for the consistent manipulation of MR datasets and their associated metadata (e.g., k-space trajectories). Second, it offers a library of composable operators, proximable functionals, and optimization algorithms, including a unified Fourier operator for all common trajectories and an extended phase graph simulation for quantitative MR. These components are used to create ready-to-use implementations of key reconstruction algorithms. Third, for deep learning, MRpro includes essential building blocks such as data consistency layers, differentiable optimization layers, and state-of-the-art backbone networks and integrates public datasets to facilitate reproducibility. MRpro is developed as a collaborative project supported by automated quality control. We demonstrate the versatility of MRpro across multiple applications, including Cartesian, radial, and spiral acquisitions; motion-corrected reconstruction; cardiac MR fingerprinting; learned spatially adaptive regularization weights; model-based learned image reconstruction and quantitative parameter estimation. MRpro offers an extensible framework for MR image reconstruction. With reproducibility and maintainability at its core, it facilitates collaborative development and provides a foundation for future MR imaging research. 2025-07-30T22:15:24Z Submitted to Magnetic Resonance in Medicine Felix Frederik Zimmermann Patrick Schuenke Christoph S. Aigner Bill A. Bernhardt Mara Guastini Johannes Hammacher Noah Jaitner Andreas Kofler Leonid Lunin Stefan Martin Catarina Redshaw Kranich Jakob Schattenfroh David Schote Yanglei Wu Christoph Kolbitsch http://arxiv.org/abs/2507.22848v1 Carotid Plaque Segmentation in Ultrasound Images Using a Mask R-CNN 2025-07-30T17:09:31Z Background: Ultrasound imaging plays a pivotal role in diagnosing carotid atherosclerosis, a significant precursor to cardiovascular and cerebrovascular diseases and events. This non-invasive modality provides real-time, high-resolution images, allowing clinicians to assess atherosclerotic plaques in the carotid arteries without invasive procedures. Purpose: In this study, we present the refinement of a Mask R-CNN model initially designed for carotid lumen detection to automatically generate bounding boxes enclosing atherosclerotic plaque for segmentation to assist in our ultrasound elastography workflow. Methods: We utilize a PyTorch torchvision implementation of the Mask R-CNN for carotid plaque detection. Our dataset consists of 118 severe stenotic carotid plaques from presenting patients, clinically indicated for a carotid endarterectomy. Due to the variability of plaque presentation in the dataset, a multitude of different R-CNN models were observed to have varying results based on the allowed number of prediction regions. An overview analysis looking at shared predictions from these models showed a slight improvement compared to the individual model results Results: Evaluation metrics such as Dice similarity coefficient and intersection over Union are employed. The model trained with 5 maximum prediction regions and tested with 2 maximum prediction regions produced the highest individual accuracy with a Dice score of 0.74 and intersection over union of 0.61. A filtered combined analysis of all the models demonstrated a slight increase in performance with scores of 0.76 and 0.61 respectively. Conclusion: Due to the significant variation in plaque presentation and types amongst presenting patients, the accuracy of the Plaque Mask R-CNN network would benefit from the incorporation of additional patient datasets to incorporate increased variation into the training dataset. 2025-07-30T17:09:31Z 14 pages, 3 figures, 4 tables Maxwell J. Kiernan Rashid Al Mukaddim Carol C. Mitchell Jenna Maybock Stephanie M. Wilbrand Robert J. Dempsey Tomy Varghese http://arxiv.org/abs/2507.22966v1 Biocompatibility of Nanomaterials in Medical Applications 2025-07-30T16:48:16Z Biocompatibility is a critical factor in the application of nanomaterials in medical fields, as these materials must interact safely and effectively with biological systems to be viable for therapeutic and diagnostic use. This article investigates the biocompatibility of nanomaterials, focusing on their interactions with biological cells, tissues, and the immune system. Key properties such as surface chemistry, size, shape, and material composition are examined, as they significantly influence the biological response. The article explores the role of nanomaterials in medical applications, including drug delivery, diagnostic imaging, and tissue engineering, while discussing the challenges involved in enhancing their biocompatibility. A case study on the CaO-CaP binary system is presented, showcasing the use of calcium oxide (CaO) and calcium phosphate (CaP) nanoparticles in bone tissue engineering. This system is widely investigated for its ability to mimic the mineral content of bone and promote osteogenesis, highlighting both its therapeutic potential and challenges in ensuring safe biocompatibility in clinical settings. The article concludes by reviewing strategies to optimize the biocompatibility of nanomaterials and discussing future directions for research in advancing their applications in medical treatments. 2025-07-30T16:48:16Z Marvellous Eyube Courage Enuesueke Marvellous Alimikhena http://arxiv.org/abs/2408.06427v3 Estimation of Multi-Component Flow in the Kidney with Multi-b-value Spectral Diffusion 2025-07-30T14:23:20Z Purpose: Examine the theory and potential clinical application of estimated intravoxel flow of separated perfusion, tubular flow, and diffusion from multi-b-value DWI in kidney allografts. Methods: Multi-b-value DWI (9 b-values; 0-800 s/mm2) from a kidney cortex is simulated with anisotropic and non-Gaussian (i.e. anomalous) vascular, tubular, and tissue components and analyzed with a Bayesian biexponential, least-squares triexponential, and spectral diffusion MRI. Comparison and application of biexponential, triexponential, and spectral diffusion fD is demonstrated in a two-center study of 54 kidney allografts patients (21F/33M, 48.8 SD 10.5years) and compared to fibrosis (Banff 2017 interstitial fibrosis and tubular atrophy score 0-6 from clinical biopsies of the renal cortex), impaired kidney function (CKD-EPI 2021 eGFR<45ml/min/1.73m2), and proteinuria. Results: Spectral diffusion fD demonstrated strong correlation to input fD of the simulated anisotropic and anomalous components. It agreed with both three-component diffusion and two-component diffusion. fD showed similar or improved agreement and correlation to input compared to individual parameters, and similar or improved agreement to corresponding bi- and triexponential models. In kidney allografts, spectral diffusion fD showed higher allograft fibrosis score had higher fD_tissue, impaired allograft function showed reduced fD_tubule, and fD_vascular negatively correlated with proteinuria across diagnostic groups of function and fibrosis. Conclusions: Spectral diffusion MRI with multi-Gaussian fD as a flow proxy separated different anomalous and anisotropic diffusion components of perfusion, tubular flow, and tissue diffusion and may hold clinical value in diffusion MRI of kidney pathophysiology. 2024-08-12T18:07:59Z Version accepted for publication in Magnetic Resonance in Imaging. Published version available at https://doi.org/10.1002/mrm.30644 Mira M. Liu Thomas Gladytz Jonathan Dyke Ian Bolger Jonas Jasse Sergio Calle Tanner Crews Surya Seshan Steven Salvatore Isaac Stillman Thangamani Muthukumar Bachir Taouli Samira Farouk Octavia Bane Sara Lewis http://arxiv.org/abs/2507.22657v1 Viscoelastic Profiling of Rare Pediatric Extracranial Tumors using Multifrequency MR Elastography: A Pilot Study 2025-07-30T13:16:38Z Objectives: Magnetic resonance elastography (MRE) is a noninvasive technique for assessing the viscoelastic properties of soft biological tissues in vivo, with potential relevance for pediatric tumor evaluation. This study aimed to evaluate the feasibility of multifrequency MRE in children with solid tumors and to report initial findings on stiffness and fluidity across rare pediatric tumor entities. Additionally, the potential of viscoelastic properties as biomarkers of tumor malignancy was explored. Materials and Methods: Ten pediatric patients (mean age, 5.7 +/- 4.8 years; four female) with extracranial solid tumors underwent multifrequency MRE. Shear waves at 30 - 70 Hz were subsequently generated and measured with a phase-sensitive single-shot spin-echo planar imaging sequence. The obtained shear wave fields were processed by wavenumber (k-)based multi-frequency inversion to reconstruct tumor stiffness and fluidity. The viscoelastic properties within the tumors were quantified and correlated with the apparent diffusion coefficient (ADC). In addition, differences in stiffness and fluidity were assessed across the histopathologically confirmed tumor entities, which were stratified into malignancy-based groups. Results: MRE was successfully performed in all patients in under five minutes. Differences in viscoelastic properties were observed among tumor entities: Stiffness, fluidity, and their spatial variability increased significantly with tumor malignancy. Furthermore, a significant inverse correlation was observed between stiffness and tumor ADC values. Conclusion: Multifrequency MRE was feasible in pediatric MRI and provided insight into tumor biomechanics. Preliminary data revealed differences in stiffness and fluidity across pediatric solid tumors correlating with malignancy. MRE holds promise for diagnosis and classification of pediatric tumor entities and their malignancy. 2025-07-30T13:16:38Z C. Metz S. Veldhoen H. E. Deubzer F. Mollica T. Meyer K. Hauptmann A. H. Hagemann A. Eggert I. Sack M. S. Anders http://arxiv.org/abs/2507.00551v2 Whole body dynamic PET kernel reconstruction using nonnegative matrix factorization features 2025-07-30T11:49:35Z The kernel reconstruction is a method that reduces noise in dynamic positron emission tomography (PET) by exploiting spatial correlations in the PET image. Although this method works well for large anatomical regions with relatively slow kinetics, whole body PET reconstruction with the kernel method can produce suboptimal results in regions with fast kinetics and high contrast. In this work we propose a new design of the spatial kernel matrix to improve reconstruction in fast and slow kinetics body regions. We calculate voxels features using nonnegative matrix factorization (NMF) with optimal rank selection. These features are then used to calculate similarities between voxels considering relative differences between features to adapt to a wide range of activity levels. Simulations and whole body mouse scans of high temporal resolution [18F]SynVesT-1, low dose [11C]raclopride, and [18F]Fallypride were performed to assess the performance of the method in different settings. In simulations, bias vs variance tradeoff and contrast was improved using the NMF kernel matrix, compared with the original kernel method. In real data, fast kinetic regions such as the heart, veins and kidneys presented oversmoothing or artifacts with the original kernel method. Our proposed method did not present these effects, while reducing noise. Brain kinetic modeling parametric maps with image derived input function ([18F]SynVesT-1) and with reference region ([11C]raclopride and [18F]Fallypride) also had lower standard error using the proposed kernel matrix compared with other methods. The NMF kernel reconstruction reduces noise and maintains high contrast in whole body PET imaging, outperforming the traditional kernel method. 2025-07-01T08:17:13Z This work has been submitted to the IEEE for possible publication Alan Miranda Steven Staelens http://arxiv.org/abs/2502.01006v3 Imaging simulation of a dual-panel PET geometry with ultrafast TOF detectors 2025-07-30T01:04:53Z In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution, demonstrating cross-sectional imaging without reconstruction. Such ultrafast TOF detectors would free PET from conventional ring geometries. Therefore, this study aimed at investigating imaging characteristics of a dual-panel PET with ultrafast TOF detectors using Geant4 simulation. Two detector panels ($137 \times 137~\text{mm}^2$), which consisted of 5.0 mm-thick bismuth germanate pixelized crystals with a 5.75 mm pitch, were placed face-to-face at a 300 mm distance. Imaging characteristics with various TOF resolutions from 30 to 90 ps were evaluated. Because degraded efficiency may cancel TOF gain in image quality, detection efficiency was also parameterized by reducing coincidence counts. Data acquisitions for a numerical multi-rod and uniform phantom (21 MBq) and a modified NEMA NU2 image quality phantom were simulated for 600 s. Results of the maximum likelihood expectation maximization (MLEM) reconstruction were compared with those of a backprojection (i.e., no reconstruction). The dual-panel PET required a 40 ps TOF resolution to have a similar spatial resolution to that of a non-TOF ring PET (300 mm in diameter) for the same detection efficiency. TOF showed benefit in the reconstruction of image quality phantom with 40% efficiency, and the image noise with 20% efficiency at 30 ps TOF was similar to the complete efficiency at 40 ps TOF. MLEM provided better imaging performance than backprojection, even at 30 ps TOF. The feasibility of the proposed dual-panel PET was shown. 2025-02-03T02:58:42Z 10 pages, 12 figures Taiyo Ishikawa Go Akamatsu Hideaki Tashima Fumihiko Nishikido Fumio Hashimoto Ryosuke Ota Hideaki Haneishi Sun Il Kwon Simon R. Cherry Taiga Yamaya http://arxiv.org/abs/2501.12057v3 Unified 3D MRI Representations via Sequence-Invariant Contrastive Learning 2025-07-29T14:41:35Z Self-supervised deep learning has accelerated 2D natural image analysis but remains difficult to translate into 3D MRI, where data are scarce and pre-trained 2D backbones cannot capture volumetric context. We present a \emph{sequence-invariant} self-supervised framework leveraging quantitative MRI (qMRI). By simulating multiple MRI contrasts from a single 3D qMRI scan and enforcing consistent representations across these contrasts, we learn anatomy-centric rather than sequence-specific features. The result is a single 3D encoder that excels across tasks and protocols. Experiments on healthy brain segmentation (IXI), stroke lesion segmentation (ARC), and MRI denoising show significant gains over baseline SSL approaches, especially in low-data settings (up to +8.3\% Dice, +4.2 dB PSNR). It also generalises to unseen sites, supporting scalable clinical use. Code and trained models are publicly available at https://github.com/liamchalcroft/contrast-squared 2025-01-21T11:27:54Z Liam Chalcroft Jenny Crinion Cathy J. Price John Ashburner http://arxiv.org/abs/2507.21853v1 Comparison of diffuse correlation spectroscopy analytical models for cerebral blood flow measurements 2025-07-29T14:27:16Z Multi-layer diffuse correlation spectroscopy (DCS) models have been developed to reduce the contamination of superficial signals in cerebral blood flow index (CBFi) measurements. However, a systematic comparison of these models and clear guidance on model selection are still lacking. This study compares three DCS analytical models: semi-infinite, two-layer, and three-layer, focusing on their fitting strategies, performance, and suitability for CBFi and relative CBFi (rCBFi) estimation. We simulated DCS data using a four-layer slab head model with the Monte Carlo eXtreme (MCX) toolkit. Multiple fitting strategies were evaluated: early time lag range (ETLR) fitting with fixed or variable beta for the semi-infinite model, and single-distance (SD) and multi-distance (MD) fitting for the two- and three-layer models. Model performance was assessed based on CBFi sensitivity, accuracy of CBFi and rCBFi recovery, resistance to signal contamination from scalp and skull, sensitivity to assumed parameter errors, and computational efficiency across source-detector separations of 20 to 35 mm. Optimal fitting methods include ETLR with fixed beta for the semi-infinite model, SD with fixed beta for the two-layer model, and MD for the three-layer model. The multi-layer models achieved higher CBFi sensitivity (up to 100%) compared to 36.8% for the semi-infinite model. The two-layer model offered the best balance of accuracy and robustness, while the three-layer model enabled simultaneous recovery of CBFi, scalp BFi, and rCBFi. The semi-infinite model was the most computationally efficient, requiring only 0.38 seconds for 500 samples, supporting its use in real-time monitoring. This work offers a practical and systematic evaluation of DCS analytical models and provides guidance for selecting the most appropriate model based on application needs. 2025-07-29T14:27:16Z 33 pages, 14 figures Mingliang Pan Quan Wang Yuanzhe Zhang David Day-Uei Li