https://arxiv.org/api/kkGZSqMsN82aFihlS6ujGgcaWro2026-06-26T13:22:46Z9008109515http://arxiv.org/abs/2508.04838v1Influence of bone microstructure on ultrasound loss through skull-mimicking digital phantoms2025-08-06T19:34:50ZTranscranial focused ultrasound applications often use simulations that require accurate acoustic properties, which can be related to computed tomography (CT) Hounsfield Units (HU). However, clinical CT is insensitive to microstructure. This study examines how bone/marrow microstructure introduces variations in acoustic property relationships to CT HUs. The insertion loss was found through skull-mimicking digital phantoms with two materials (bone/marrow) from 0 to 75% porosity. The phantoms had one of six pore diameters ranging from 0.2 mm to 1.0 mm. k-Wave simulations were computed with a continuous 230 kHz or 650 kHz uniform pressure source. The insertion loss was defined as the transmitted mean pressure relative to a water-only reference. The 230 kHz loss changed with porosity, but microstructure had little effect. However, the 650 kHz loss in both non-absorbing and absorbing simulations depended on porosity and pore diameter. Larger pore phantoms generally had higher losses than smaller pore diameter phantoms at the same porosity. In the non-absorbing phantoms, the maximum range in insertion loss was 2% to 52%, which occurred at 20% porosity. Absorption increased the loss by 8.2% on average, with the greatest increase of 13% in the smallest pore (0.2 mm) and 2.5% porosity phantom. Coherent multiple reflections from the phantom's planar interfaces influenced the loss from smaller pores, while larger pores disrupt this phase coherence. The insertion loss dependence on porosity and pore diameter shows that the attenuation-HU relationship is ill-determined at 650 kHz. This uncertainty has implications for CT-derived acoustic models, as no single attenuation corresponds to HUs with variable microstructures.2025-08-06T19:34:50ZSubmitted to Medical PhysicsMed Phys. 2025; 52:e70113Samuel ClinardTaylor WebbHenrik OdéenDennis L. ParkerDouglas A. Christensen10.1002/mp.70113http://arxiv.org/abs/2508.04484v1A high-order deterministic dynamical low-rank method for proton transport in heterogeneous media2025-08-06T14:34:27ZDose calculations in proton therapy require the fast and accurate solution of a high-dimensional transport equation for a large number of (pencil) beams with different energies and directions. Deterministically solving this transport problem at a sufficient resolution can however be prohibitively expensive, especially due to highly forward peaked scattering of the protons. We propose using a model order reduction approach, the dynamical low-rank approximation (DLRA), which evolves the solution on the manifold of low-rank matrices in (pseudo-)time. For this, we compare a collided-uncollided split of the linear Boltzmann equation and its Fokker-Planck approximation. We treat the uncollided part using a ray-tracer and combine high-order phase space discretizations and a mixture model for materials with DLRA for the collided equation. Our method reproduces the results of a full-rank reference code at significantly lower rank, and thus computational cost and memory, and further makes computations feasible at much higher resolutions. At higher resolutions, we also achieve good accuracy with respect to TOPAS MC in homogeneous as well as heterogeneous materials. Finally, we demonstrate that several beam sources with different angles can be computed with little cost increase compared to individual beams.2025-08-06T14:34:27ZPia StammerNiklas WahlJonas KuschDanny Lathouwershttp://arxiv.org/abs/2508.04432v13D Mapping of Static Magnetic Field Magnitude and AxialComponents around a total body 3T MRI clinical scanner2025-08-06T13:17:46ZObjective. The technology employed in magnetic resonance imaging (MRI) systems has evolved continuously, resulting in MRI scanners with stronger static magnetic fields (SMF) B0, faster and stronger gradient magnetic fields, and more powerful radiofrequency transmission coils. The most well-known hazard associated with an MRI environment is the projectile effect due to Spatial Field Gradient (SFG). Furthermore, movement through the SFG generates a time-varying magnetic field, which in turn induces a voltage in body tissues. This has the potential to result in a range of physiological symptoms, including headache, nausea, vertigo, phosphenes, numbness, tingling, loss of proprioception, and balance disturbances.
Approach. The methodology outlined in this study provides a comprehensive and reliable approach to creating a 3D map of the SMF (fringe field) around a clinical MRI facility. The methodology involves measuring the unperturbed B field, including magnitude and axial components, in specific points and subsequently performing a mathematical procedure involving fitting and interpolation.
Main results. Fringe field magnitude and axial components 3D maps are presented for a 3T whole-body MRI scanner for clinical application located in a hospital facility.
Significance. The map obtained could be used for a number of purposes, including the evaluation of hazard. This could be achieved by using digital tools to create a simulation of all types of MRI workers movements within the facility. The map could also be used for the training and education of MRI operators, with a view to establishing best practices. The estimation of magnetic field axial components represents a valuable enhancement, as these data can be used to calculate induced electric fields during rotational movements, such as those of the head or torso.2025-08-06T13:17:46Z13 pages, 10 figuresFront. Public Health, 7 Oct 2025Francesco GirardelloMaria Antonietta D'AvanzoMassimo MattozziVictorian Michele FerroGiuseppe AcriValentina Hartwig10.3389/fpubh.2025.1625728http://arxiv.org/abs/2410.17557v2BlurryScope enables compact, cost-effective scanning microscopy for HER2 scoring using deep learning on blurry images2025-08-06T04:42:55ZWe developed a rapid scanning optical microscope, termed "BlurryScope", that leverages continuous image acquisition and deep learning to provide a cost-effective and compact solution for automated inspection and analysis of tissue sections. This device offers comparable speed to commercial digital pathology scanners, but at a significantly lower price point and smaller size/weight. Using BlurryScope, we implemented automated classification of human epidermal growth factor receptor 2 (HER2) scores on motion-blurred images of immunohistochemically (IHC) stained breast tissue sections, achieving concordant results with those obtained from a high-end digital scanning microscope. Using a test set of 284 unique patient cores, we achieved testing accuracies of 79.3% and 89.7% for 4-class (0, 1+, 2+, 3+) and 2-class (0/1+, 2+/3+) HER2 classification, respectively. BlurryScope automates the entire workflow, from image scanning to stitching and cropping, as well as HER2 score classification.2024-10-23T04:46:36Z22 Pages, 5 Figures, 1 Tablenpj Digital Medicine (2025)Michael John FanousChristopher Michael SeyboldHanlong ChenNir PillarAydogan Ozcan10.1038/s41746-025-01882-xhttp://arxiv.org/abs/2508.03960v1Fast Magnetic Resonance Simulation Using Combined Update with Grouped Isochromats2025-08-05T22:53:51ZThis work aims to overcome an assumption of conventional MR simulators: Individual isochromats should be simulated individually. To reduce the computational times of MR simulation, a new simulation method using grouped isochromats is proposed. When multiple isochromats are grouped before simulations, some parts of the simulation can be shared in each group. For a certain gradient type, the isochromats in the group can be easily chosen for ensuring that they behave the same. For example, the group can be defined as the isochromats whose locations along x-axis, T1, T2 and magnetic field inhomogeneity values are the same values. In such groups, simulations can be combined when a pulse sequence with the magnetic field gradient along x-axis only are processed. The processing times of the conventional and proposed methods were evaluated with several sequences including fast spin echo (FSE) and echo-planar imaging (EPI) sequences. The simulation times of the proposed method were 3 to 72 times faster than those of the conventional methods. In the cases of 27.5 million isochromats using single instruction multiple data (SIMD) instructions and multi-threading, the conventional method simulated FSE and EPI sequences in 208.4 and 66.4 seconds, respectively. In the same cases, the proposed method simulated these sequences in 38.1 and 7.1 seconds, respectively.2025-08-05T22:53:51ZHidenori Takeshima10.2463/mrms.mp.2025-0131http://arxiv.org/abs/2508.03657v1High-Resolution Dynamic Full-Field Optical Coherence Microscopy: Illuminating Intracellular Activity in Deep Tissue2025-08-05T17:10:03ZDynamic full-field optical coherence microscopy (d-FF-OCM) is a label-free imaging technique that captures intrinsic subcellular motions to generate functional contrast. This dynamic approach yields images with fluorescence-like contrast, highlighting active structures without the need for fluorescent labels. However, current d-FF-OCM implementations struggle to image deep within highly scattering tissues at high resolution. Here, we present a new high-resolution d-FF-OCM system that overcomes these limitations, enabling much deeper high-resolution imaging in such tissues. The setup uses 100x oil-immersion objectives (NA = 1.25) and a high-brightness, laser-pumped incoherent white light source to achieve nanometer-scale resolution at depths up to approximately 100 micrometers in highly scattering samples. We also incorporate real-time reference arm adjustment to maintain signal strength and contrast as the focus moves deeper into the sample. Using this system, we imaged fresh ex vivo mouse liver and small intestine with unprecedented depth and detail. In these tissues, the dynamic contrast clearly revealed fine structures not visible with conventional OCT-for example, the sinusoidal microvasculature and organized cell layers in the liver, as well as neural plexuses and crypts in the intestine-all visualized label-free. By bridging the gap between high-resolution and deep imaging in highly scattering tissue, this advance provides a powerful new tool for biological microscopy, with potential applications from fundamental research to rapid intraoperative pathology.2025-08-05T17:10:03Z16 pages, 10 figuresErikas TarvydasAusteja TreciokaiteEgidijus Auksoriushttp://arxiv.org/abs/2508.03605v1$β$-Ga$_2$O$_3$--Based Radiation Detector for Proton Therapy2025-08-05T16:20:16ZIntensity modulated proton therapy (IMPT) is an advanced cancer treatment modality that offers significant advantages over conventional X-ray therapies, particularly in its ability to minimize radiation dose beyond the tumor target. This reduction in unnecessary irradiation exposure significantly lowers the risk to surrounding healthy tissue and reduces side effects compared to conventional X-ray treatments. However, due to the high complexity of IMPT plans, each plan must be independently validated to ensure the safety and efficacy of the radiation exposure to the patient. While ion chambers are currently used for this purpose, their limitations-particularly in angled-beam measurements and multi-depth assessments-hinder their effectiveness. Silicon-based detectors, commonly used in X-ray therapy, are unsuitable for IMPT due to their rapid degradation under proton irradiation. In this study, a $β$-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector was evaluated and compared with a commercial ion chamber using a MEVION S250i proton accelerator. The $β$-Ga$_2$O$_3$ detector demonstrated reliable detection of single-pulse proton doses as low as 0.26 MU and exhibited a linear charge-to-dose relationship across a wide range of irradiation conditions. Furthermore, its measurement variability was comparable to that of the ion chamber, with improved sensitivity observed at higher bias voltages. These results highlight the strong potential of $β$-Ga$_2$O$_3$ as a radiation-hard detector material for accurate dose verification in IMPT.2025-08-05T16:20:16Z16 page, 5 figuresHunter D. EllisImteaz RahamanApostoli HillasBotong LiVikren SarkarKai Fuhttp://arxiv.org/abs/2508.03220v1Timing is everything: How subtle timing changes in MRI echo planar imaging can significantly alter mechanical vibrations and sound level2025-08-05T08:46:43ZModern MRI relies on the well-established Echo-Planar-Imaging (EPI) method for fast acquisition. EPI is the workhorse of diffusion and functional MRI in neuroscience as well as of many dynamic applications for clinical body imaging. Its speed stems from rapidly switching currents through the gradient coils responsible for spatial encoding. These quick changes, within a strong static magnetic field induce Lorentz forces that generate mechanical vibrations, leading to the loud, characteristic MRI noise. This acoustic noise is already a significant concern in standard clinical scanners, requiring hearing protection and risking image degradation or even hardware strain. In ultra-high-field systems, the issue is exacerbated due to stronger Lorentz forces. In this study, we introduce a novel model that characterizes the acoustic spectrum for a given EPI scan. The spectrum results from interference between multiple identical periods of alternating currents, making the relative timing between them a key factor. We show that even subtle timing changes significantly alter the sound level. Scans of either high spatial resolution or high temporal resolution, on clinical 7T and investigational 10.5T human scanners, corroborated the model and its predicted acoustics spectra. Acoustic energy changes of up to 47-fold were reached in close to mechanical resonances and up to 5-fold in other regions. Intriguingly, under certain conditions, doubling the acquisitions per unit time actually reduced the minimal acoustic energy two-fold. Not less important, ghosting-artifacts exhibit strong dependence on the scan's acoustic characteristics and the benefit of subtle time delays of internal correction-acquisitions (navigators) is also demonstrated.2025-08-05T08:46:43ZAmir SeginerAlexander BratchShahar GorenEdna Furman-HaranNoam HarelEssa YacoubRita Schmidthttp://arxiv.org/abs/2508.11655v1Stretchable and self-adhesive triboelectric sensor for real-time musculoskeletal monitoring and personalized recovery2025-08-05T02:01:15ZRecent advances in medical diagnostics have highlighted the importance of wearable technologies for continuous and real-time physiological monitoring. In this study, we introduce a flexible, self-powered triboelectric nanogenerator (MB-TENG) engineered from commercially available medical elastic bandages for biomechanical sensing during rehabilitation and gait analysis. Leveraging the porous and skin-friendly properties of the bandage combined with a PTFE film, the MB-TENG delivers robust electrical performance, achieving a peak open-circuit voltage (VOC) of 122~V, a short-circuit current (ISC) of 25~$μ$A, and a transferred charge (QSC) of 110~nC, while maintaining long-term stability across 40{,}000 mechanical cycles. Its inherent self-adhesive property allows for multi-layer assembly without extra bonding agents, and mechanical stretching enhances output, enabling dual configurability. A stacked design further improves the power capacity, supporting applications in wearable medical electronics. The MB-TENG device seamlessly conforms to joint surfaces and foot regions, providing accurate detection of motion states and abnormal gait patterns. These features underscore the MB-TENG's potential as a low-cost, scalable platform for personalized rehabilitation, injury monitoring, and early musculoskeletal diagnosis.2025-08-05T02:01:15ZCai LinYunyi DingKai LinRu WangYichen LuoXiaofen Wuhttp://arxiv.org/abs/2508.02899v1Optimal control driven functional electrical stimulation: A scoping review2025-08-04T21:00:54ZIntroduction: Rehabilitation after a neurological impairment can be supported by functional electrical stimulation (FES). However, FES is limited by early muscle fatigue, slowing down the recovery progress. The use of optimal control to reduce overstimulation and improve motion precision is gaining interest. This review aims to map the current literature state meanwhile clarifying the best practices, identifying persistent challenges, and outlining directions for future research. Methods: Following the PRISMA guidelines, a search was conducted up to February 2024 using the combined keywords "FES", "optimal control" or "fatigue" across five databases (Medline, Embase, CINAHL Complete, Web of Science, and ProQuest Dissertations & Theses Citation Index). Inclusion criteria included the use of optimal control with FES for healthy individuals and those with neuromuscular disorders. Results: Among the 44 included studies, half were in silico and half in vivo, involving 87 participants, predominantly healthy young men. Twelve different motor tasks were investigated, with a focus on single joint lower limb movements. These studies principally used simple FES models, modulating pulse width or intensity to track joint angle. Conclusions: Optimal control-driven FES can deliver precise motions and reduce fatigue. Yet clinical adoption is slowed down by the lack of consensus about modelling, inconvenient model identification protocol and limited validation. Additional barriers include insufficient open-science practices, computational performance reporting and the availability of customizable commercial hardware. Comparative FES model studies and longitudinal trials with large cohorts, among other efforts, are required to improve the technology readiness level. Such advances would help clinical adoption and improve patient outcomes.2025-08-04T21:00:54Z37 pages, 7 figures, 3 tablesKevin CoMickaël BegonFrançois BaillyFlorent Moissenethttp://arxiv.org/abs/2508.02169v1A Dual Radiomic and Dosiomic Filtering Technique for Locoregional Radiation Pneumonitis Prediction in Breast Cancer Patients2025-08-04T08:07:31ZPurpose: Radiation pneumonitis (RP) is a serious complication of intensity-modulated radiation therapy (IMRT) for breast cancer patients, underscoring the need for precise and explainable predictive models. This study presents an Explainable Dual-Omics Filtering (EDOF) model that integrates spatially localized dosiomic and radiomic features for voxel-level RP prediction.
Methods: A retrospective cohort of 72 breast cancer patients treated with IMRT was analyzed, including 28 who developed RP. The EDOF model consists of two components: (1) dosiomic filtering, which extracts local dose intensity and spatial distribution features from planning dose maps, and (2) radiomic filtering, which captures texture-based features from pre-treatment CT scans. These features are jointly analyzed using the Explainable Boosting Machine (EBM), a transparent machine learning model that enables feature-specific risk evaluation. Model performance was assessed using five-fold cross-validation, reporting area under the curve (AUC), sensitivity, and specificity. Feature importance was quantified by mean absolute scores, and Partial Dependence Plots (PDPs) were used to visualize nonlinear relationships between RP risk and dual-omic features.
Results: The EDOF model achieved strong predictive performance (AUC = 0.95 +- 0.01; sensitivity = 0.81 +- 0.05). The most influential features included dosiomic Intensity Mean, dosiomic Intensity Mean Absolute Deviation, and radiomic SRLGLE. PDPs revealed that RP risk increases beyond 5 Gy and rises sharply between 10-30 Gy, consistent with clinical dose thresholds. SRLGLE also captured structural heterogeneity linked to RP in specific lung regions.
Conclusion: The EDOF framework enables spatially resolved, explainable RP prediction and may support personalized radiation planning to mitigate pulmonary toxicity.2025-08-04T08:07:31Z39 pages, 6 figures, 1 tableZhenyu YangQian ChenRihui ZhangManju LiuFengqiu GuoMinjie YangMin TangLina ZhouChunhao WangMinbin ChenFang-Fang Yinhttp://arxiv.org/abs/2508.02767v1Mechanical characterization of pharmaceutical powders and correlation with their behavior during grinding2025-08-04T07:04:30ZControlling the size of powder particles is pivotal in the design of many pharmaceutical forms and the related manufacturing processes and plants. One of the most common techniques for particle size reduction in process industry is powder milling, whose efficiency relates to the mechanical properties of powder particles themselves. In this work, we first characterize the elastic and plastic response of different pharmaceutical powders by measuring their Young modulus, the hardness and the brittleness index via nano-indentation. Subsequently, we analyze the behavior of those powder samples during comminution via jet-mill at different process conditions. Finally, the correlation between single particle mechanical properties and milling process results is illustrated; the possibility to build a predictive model for powder grindability, based on nano-indentation data, is critically discussed2025-08-04T07:04:30ZPharmaceutics 14(2022) 1146Laura BaraldiDavide De AngelisRoberto BosiRoberto PenniniIrene BassanettiAndrea BenassiGuido Enrico Bellazzi10.3390/pharmaceutics14061146http://arxiv.org/abs/2508.02060v1Density-encoded line integral convolution: polarisation optical axis tractography using centroidal Voronoi tessellation2025-08-04T04:59:26ZVisualising complex polarimetry optical axis fields is challenging. We introduce density-encoded line integral convolution (DELIC), a novel approach that builds on the classic line integral convolution algorithm by incorporating the principles of centroidal Voronoi tessellation, enabling clearer and more interpretable representations of complex optical axis fields.2025-08-04T04:59:26Z5 pages, 3 figuresDarven Murali TharanThe University of Auckland, Department of Physics, New ZealandThe Dodd Walls Centre for Quantum and Photonic TechnologyMarco BonesiThe University of Auckland, Department of Physics, New ZealandThe Dodd Walls Centre for Quantum and Photonic TechnologyDaniel EverettThe Dodd Walls Centre for Quantum and Photonic TechnologyThe University of Auckland, Department of Chemical and Materials Engineering, New ZealandCushla McGoverinThe University of Auckland, Department of Physics, New ZealandThe Dodd Walls Centre for Quantum and Photonic TechnologySue McGlashanThe University of Auckland, Department of Anatomy and Medical Imaging, New ZealandAshvin ThambyahThe University of Auckland, Department of Chemical and Materials Engineering, New ZealandFrédérique VanholsbeeckThe University of Auckland, Department of Physics, New ZealandThe Dodd Walls Centre for Quantum and Photonic Technologyhttp://arxiv.org/abs/2409.07375v2PRIME: Phase Reversed Interleaved Multi-Echo acquisition enables highly accelerated distortion-free diffusion MRI2025-08-03T01:20:37ZPurpose: To develop and evaluate a new pulse sequence for highly accelerated distortion-free diffusion MRI (dMRI) by inserting additional echoes without prolonging TR, when generalized slice dithered enhanced resolution (gSlider) radiofrequency encoding is used for volumetric acquisition. Methods: A phase-reversed interleaved multi-echo acquisition (PRIME) was developed for rapid, high-resolution, and distortion-free dMRI, which includes several echoes where the first echo is for target diffusion-weighted imaging (DWI) acquisition with high-resolution and additional echoes are acquired with either lower resolution for 1) high-fidelity field map estimation, 2) phase navigation for shot-to-shot phase correction, 3) motion navigation across diffusion directions, or with high resolution to enable 4) high fidelity diffusion relaxometry acquisitions. The sequence was evaluated on in vivo data acquired from healthy volunteers on clinical and Connectome 2.0 scanners. Results: In vivo experiments demonstrated that 1) high in-plane acceleration (Rin-plane of 5-fold with 2D partial Fourier) was achieved using the high-fidelity field maps estimated from the second echo, which was made at a lower resolution/acceleration to increase its SNR while matching the effective echo spacing of the first readout, 2) high-resolution diffusion relaxometry parameters were estimated from triple-echo PRIME data using a white matter model of multi-TE spherical mean technique (MTE-SMT), and 3) high-fidelity mesoscale DWI at 490 um isotropic resolution was obtained in vivo by capitalizing on the high-performance gradients of the Connectome 2.0 scanner. Conclusion: The proposed PRIME sequence enabled highly accelerated, high-resolution, and distortion-free dMRI using additional echoes without prolonging scan time when gSlider encoding is utilized.2024-09-11T16:06:33Z14 figures, 1 tableYohan JunQiang LiuTing GongJaejin ChoShohei FujitaXingwang YongCongyu LiaoMarianna E SchmidtShahin NasrCamilo JaimesMichael S GeeSusie Y HuangLipeng NingAnastasia YendikiYogesh RathiBerkin Bilgichttp://arxiv.org/abs/2508.01234v1Impact of Solar Particle Events on Space Radiation Shielding: OLTARIS Simulation and Quantum Optimization of Material Selection using QAOA and VQE Algorithms2025-08-02T07:20:49ZSpace radiation poses a significant challenge for long duration human space missions, with sources including Galactic Cosmic Rays, Solar Particle Events, and trapped particles in the Van Allen belts. These high-energy radiations cause severe biological effects on astronauts and degrade spacecraft systems, making effective shielding critical. Traditionally, passive shielding materials like aluminum have been used, but their limitations, particularly in generating secondary radiation, necessitate better alternatives. In this study, the performance of shielding materials such as lithium hydride, polyethylene, lithium borohydride, beryllium borohydride, and ammonia borane are evaluated in GCR and SPE environments using OLTARIS, a NASA developed tool. The October 1989 SPE is used to study particle flux and dose distributions. Shielding effectiveness varies by environment. Beryllium borohydride performs best in SPE, while lithium hydride gives the lowest dose in GCR. In SPE, performance is linked to hydrogen content. Effect of Solar modulation on GCR dose is also studied. Higher modulation lowers GCR intensity and dose. The complex nature of high energy space radiation and material combinations creates computational challenges. To address this, the material selection problem is modeled as a Quadratic Unconstrained Binary Optimization and solved using the Variational Quantum Eigensolver and Quantum Approximate Optimization Algorithm. Mapping OLTARIS data to the Ising model and applying these quantum classical methods helped identify shielding setups that minimize radiation dose. Results show agreement between OLTARIS and quantum optimization for both environments.2025-08-02T07:20:49Z28 pages in PDF, Figure 15Kavita LalwaniSreedevi V. V.Munish GakharDiya Agrawal