https://arxiv.org/api/jIt23O7PC5E19oiwJ6/3OC9se2A 2026-06-26T12:11:33Z 9008 1080 15 http://arxiv.org/abs/2508.08803v1 Steady-State Free Precession NMR in the Presence of Heteronuclear Couplings and Decoupling: More Than Meets the Eye 2025-08-12T09:57:40Z Fourier Transform (FT) has been a mainstay of analytical 13C and 15N NMR. On the other hand it has been shown that Steady State Free Precession (SSFP) experiments which depart from this scheme can, under certain conditions, endow 13C and 15N small molecule NMR with comparable sensitivity and resolution. SSFP is one of the earliest and most widely used NMR pulse sequences, yet its analyses have focused on isolated spin-half ensembles such as water. The present study demonstrates that significant deviations from such isolated spin-half behavior may occur when SSFP is applied in the presence of spin-spin couplings. Even in the simplest case supporting such couplings, a single 13C J coupled to a 1H, departures from the isolated spin-half behavior arise in the 13C SSFP response, both in the absence and in the presence of 1H spin decoupling. In the former case deviations are produced by the differential relaxation of antiphase two-spin terms generated by the pulse train; in the latter case, magnified interferences may arise between the SSFP pulses and the coherent perturbation arising upon 1H decoupling. Although both phenomena are also known in FT NMR, the spectral distortions that they will originate may be much larger in the SSFP case, particularly if interpulse delays in large flip angle SSFP pulse trains resonate with the coupling perturbations. The origins of these effects are here analyzed for heteronuclear spin-half systems and corroborated with 13C NMR SSFP experiments recorded under different conditions. Additional considerations aimed at magnifying or suppressing these effects, as well as extensions to more complex scenarios, are also briefly discussed. 2025-08-12T09:57:40Z Sundaresan Jayanthi Zuzana Osifová Mark Shif Adonis Lupulescu Lucio Frydman http://arxiv.org/abs/2508.08515v1 Beam hardening correction of Bremsstrahlung X-ray computed tomography measurements and required measurement accuracies 2025-08-11T22:51:23Z Doing quantitative computed tomography (CT) using Bremsstrahlung sources requires an estimate of the spectrum emitted by the X-ray source. One method of beam hardening correction (BHC), as described by Lifton[1], first uses transmission measurements of a known material and range of thicknesses to estimate the spectrum and then uses the estimated spectrum to correct the beam hardening error, not necessarily on the same material as used for estimating the spectrum. We adopt Lifton's BHC procedure and through simulations show how the uncertainties in the transmission measurements and the uncertainties in the material thickness measurements propagate to uncertainties in the spectrum, the beam hardening correction curve and thence to uncertainties in the beam hardening corrected CT reconstruction. 2025-08-11T22:51:23Z 7 pages, 5 figures Nikhil Deshmukh http://arxiv.org/abs/2508.08434v1 Stochastic Reconstruction of the Speed of Sound in Breast Ultrasound Computed Tomography with Phase Encoding in the Frequency Domain 2025-08-11T19:46:05Z The framework of ultrasound computed tomography (USCT) has recently re-emerged as a powerful, safe and operator-independent way to image the breast. State of the art image reconstruction methods are performed with iterative techniques based on deterministic optimization algorithms in the frequency domain in the 300 kHz - 1 MHz bandwidth. Alternative algorithms with deterministic and stochastic optimization have been considered in the time-domain. In this paper, we present the equivalent stochastic inversion in the frequency domain (phase encoding), with a focus on reconstructing the speed of sound. We test the inversion algorithm on synthetic data in 2D and 3D, by explicitly differentiating between inverse crime and non-inverse crime scenarios, and compare against the deterministic inversion. We then show the results of the stochastic inversion in the frequency domain on experimental data. By leveraging on the concepts of multiple super-shots and stochastic ensembles, we provide robust evidence that image quality of a stochastic reconstruction of the speed of sound with phase encoding in the frequency domain is comparable, and essentially equivalent, to the one of a deterministic reconstruction, with the further benefit of drastically reducing reconstruction times by more than half. 2025-08-11T19:46:05Z Luca A. Forte http://arxiv.org/abs/2506.10073v2 Patient-Specific Deep Reinforcement Learning for Automatic Replanning in Head-and-Neck Cancer Proton Therapy 2025-08-11T19:44:49Z Anatomical changes during intensity-modulated proton therapy (IMPT) for head-and-neck cancer (HNC) can shift Bragg peaks, risking tumor underdosing and organ-at-risk overdosing. Treatment replanning is often required to maintain clinically acceptable treatment quality. However, current manual replanning processes are resource-intensive and time-consuming. We propose a patient-specific deep reinforcement learning (DRL) framework for automated IMPT replanning, with a reward-shaping mechanism based on a $150$-point plan quality score addressing competing clinical objectives. We formulate the planning process as a reinforcement learning problem where agents learn control policies to adjust optimization priorities, maximizing plan quality. Unlike population-based approaches, our framework trains agents for each patient using their planning Computed Tomography (CT) and augmented anatomies simulating anatomical changes (tumor progression and regression). This patient-specific approach leverages anatomical similarities along the treatment course, enabling effective plan adaptation. We implemented two DRL algorithms, Deep Q-Network and Proximal Policy Optimization, using dose-volume histograms (DVHs) as state representations and a $22$-dimensional action space of priority adjustments. Evaluation on eight HNC patients using actual replanning CT data showed that both agents improved initial plan scores from $120.78 \pm 17.18$ to $139.59 \pm 5.50$ (DQN) and $141.50 \pm 4.69$ (PPO), surpassing the replans manually generated by a human planner ($136.32 \pm 4.79$). Clinical validation confirms that improvements translate to better tumor coverage and OAR sparing across diverse anatomical changes. This work highlights DRL's potential in addressing geometric and dosimetric complexities of adaptive proton therapy, offering efficient offline adaptation solutions and advancing online adaptive proton therapy. 2025-06-11T18:00:06Z Published in Proceedings of Machine Learning Research (PMLR) 298; accepted at Machine Learning for Healthcare Conference (MLHC) 2025 Malvern Madondo Yuan Shao Yingzi Liu Jun Zhou Xiaofeng Yang Zhen Tian http://arxiv.org/abs/2503.10527v2 Evaluating structural uncertainty in accelerated MRI: are voxelwise measures useful surrogates? 2025-08-11T17:36:37Z Introducing accelerated reconstruction algorithms into clinical settings requires measures of uncertainty quantification that accurately assess the relevant uncertainty introduced by the reconstruction algorithm. Many currently deployed approaches quantifying uncertainty by focusing on measuring the variability in voxelwise intensity variation. Although these provide interpretable maps, they lack a structural interpretation and do not show a clear relationship to how the data will be analysed subsequently. In this work we show that voxel level uncertainty does not provide insight into morphological uncertainty. To do so, we use segmentation as a clinically-relevant downstream task and deploy ensembles of reconstruction modes to measure uncertainty in the reconstructions. We show that variability and bias in the morphological structures are present and within-ensemble variability cannot be predicted well with uncertainty measured only by voxel intensity variations. 2025-03-13T16:34:22Z Luca L. C. Trautmann Peter A. Wijeratne Itamar Ronen Ivor J. A. Simpson http://arxiv.org/abs/2508.08079v1 A Computational Optimisation Study of Hip Implant Using Density Mapping Functionally Graded Biomimetic TPMS-based Lattice Structures 2025-08-11T15:27:31Z This study presents a computational optimisation framework of a hip implant through the development of a functionally graded biomimetic lattice structure, whose design was structurally optimised to limit stress shielding. The optimisation technique was inspired by the inverse of a bone remodelling algorithm, promoting an even stress distribution throughout the design region, by reducing the density and consequently the stiffness, in regions where strain energy was higher than the reference level. The result of the optimisation technique provided a non-uniform graded density distribution field that showed lower density level on the sides of the implant stem, and higher material density around the medial axis of the stem. The optimised material distribution was captured using mapping of a triply periodic minimal surface lattice structure on the implant, which resulted in porous lattice surfaces inside the solid implant. The performance of the porous implant design was evaluated through implementation of a finite element bone remodelling algorithm and comparing the bone response with a femur with fully solid implant model, in terms of stress distribution and mass change. The results of the analysis showed improved bone formation on the bone-implant interface, and enhanced stress transmission to the surrounding bone from the implant. 2025-08-11T15:27:31Z Data availability at https://doi.org/10.5281/zenodo.14906052 npj Metamaterials 1, 3 (2025) Mahtab Vafaeefar Conall Quinn Kevin M. Moerman Ted J. Vaughan 10.1038/s44455-025-00003-8 http://arxiv.org/abs/2508.08030v1 Exploring Strategies for Personalized Radiation Therapy: Part III Identifying genetic determinants for Radiation Response with Meta Learning 2025-08-11T14:34:18Z Radiation response in cancer is shaped by complex, patient specific biology, yet current treatment strategies often rely on uniform dose prescriptions without accounting for tumor heterogeneity. In this study, we introduce a meta learning framework for one-shot prediction of radiosensitivity measured by SF2 using cell line level gene expression data. Unlike the widely used Radiosensitivity Index RSI a rank-based linear model trained on a fixed 10-gene signature, our proposed meta-learned model allows the importance of each gene to vary by sample through fine tuning. This flexibility addresses key limitations of static models like RSI, which assume uniform gene contributions across tumor types and discard expression magnitude and gene gene interactions. Our results show that meta learning offers robust generalization to unseen samples and performs well in tumor subgroups with high radiosensitivity variability, such as adenocarcinoma and large cell carcinoma. By learning transferable structure across tasks while preserving sample specific adaptability, our approach enables rapid adaptation to individual samples, improving predictive accuracy across diverse tumor subtypes while uncovering context dependent patterns of gene influence that may inform personalized therapy. 2025-08-11T14:34:18Z Hao Peng Yuanyuan Zhang Steve Jiang Robert Timmerman John Minna http://arxiv.org/abs/2504.10524v3 Hemodynamic Markers: CFD-Based Prediction of Cerebral Aneurysm Rupture Risk 2025-08-10T17:46:21Z This study investigates the influence of aneurysm evolution on hemodynamic characteristics within the sac region. Using computational fluid dynamics (CFD), blood flow through the parent vessel and aneurysm sac was analyzed to assess the impact on wall shear stress (WSS), time-averaged wall shear stress (TAWSS), and the oscillatory shear index (OSI), key indicators of rupture risk. Additionally, Relative Residence Time (RRT) and Endothelial Cell Activation Potential (ECAP) were examined to provide a broader understanding of the aneurysm's hemodynamic environment. Six distinct cerebral aneurysm (CA) models, all from individuals of the same gender, were selected to minimize gender-related variability. Results showed that unruptured cases exhibited higher WSS and TAWSS, along with lower OSI and RRT values patterns consistent with stable flow conditions supporting vascular integrity. In contrast, ruptured cases had lower WSS and TAWSS, coupled with elevated OSI and RRT, suggesting disturbed and oscillatory flow commonly linked to aneurysm wall weakening. ECAP was also higher in ruptured cases, indicating increased endothelial activation under unstable flow. Notably, areas with the highest OSI and RRT often aligned with vortex centers, reinforcing the association between disturbed flow and aneurysm instability. These findings highlight the value of combining multiple hemodynamic parameters for rupture risk assessment. Including RRT and ECAP provides deeper insight into flow endothelium-interactions, offering a stronger basis for evaluating aneurysm stability and guiding treatment decisions. 2025-04-11T22:59:31Z 16 figures, 24 pages Reza Bozorgpour Jacob R. Rammer 10.1016/j.vph.2025.107578 http://arxiv.org/abs/2508.07133v1 Computational modeling of Pulsed Field Ablation for pulmonary vein isolation 2025-08-10T01:02:04Z Pulsed field ablation (PFA) has emerged as a non-thermal alternative to traditional thermal ablation techniques for the treatment of atrial fibrillation (AF). This study presents a patient-specific 3D computational framework to model the effects of PFA on pulmonary vein isolation (PVI). The modeling framework is rigorously validated against published numerical and experimental data, demonstrating strong agreement across a range of scenarios. Using realistic left atrial (LA) anatomy, commercially available circular, flower, and basket catheter configurations are simulated to evaluate lesion formation across different applied voltages. The performance of each catheter type is quantitatively assessed using multiple metrics, including lesion volume, energy delivery efficiency and transmurality. Simulation results show that circular catheters provide the highest energy delivery efficiency and target coverage at lower voltages, while basket catheters produce the largest lesion volumes. This framework offers a useful basis for exploring catheter design and treatment planning in PFA applications. 2025-08-10T01:02:04Z Ashkan Bagherzadeh Nagib T Chalfoun Tong Gao Lik Chuan Lee http://arxiv.org/abs/2508.06644v1 Detecting Early Kidney Allograft Fibrosis with Multi-b-value Spectral Diffusion MRI 2025-08-08T18:45:54Z Kidney allograft fibrosis is a marker of chronic kidney disease (CKD) and predicts functional decline, and eventual allograft failure. This study evaluates if spectral diffusion MRI can help detect early development and mild/moderate fibrosis in kidney allografts. In a prospective two-center study of kidney allografts, interstitial fibrosis and tubular atrophy (IFTA) was scored and eGFR was calculated from serum creatinine. Multi-b-value DWI (bvalues=[0,10,30,50,80,120,200,400,800mm2/s]) was post-processed with spectral diffusion, intravoxel incoherent motion (IVIM), and apparent diffusion coefficient (ADC). Connection between imaging parameters and biological processes was measured by Mann-Whitney U-test and Spearman's rank; diagnostic ability was measured by five-fold cross-validation univariate and multi-variate logistic regression. Quality control analyses included volunteer MRI (n=4) and inter-observer analysis (n=19). 99 patients were included (50$\pm$13yo, 64M/35F, 39 IFTA=0, 22 IFTA=2, 20 IFTA=4, 18 IFTA=6, 46 eGFR<=45mL/min/1.73m2, mean eGFR=47.5$\pm$21.3mL/min/1.73m2). Spectral diffusion detected fibrosis (IFTA>0) in patients with normal/stable eGFR>45ml/min/1.73m2 [AUC(95$\%$CI)=0.72(0.56,0.87),p=0.007]. Spectral diffusion detected mild/moderate fibrosis (IFTA=2-4) [AUC(95$\%$CI)=0.65(0.52,0.71),p=0.023], as did ADC [AUC(95$\%$CI)=0.71(0.54,0.87),p=0.013)]. eGFR, time-from-transplant, and allograft size could not. Interobserver correlation was >0.50 in 24 out of 40 diffusion parameters. Spectral diffusion MRI showed detection of mild/moderate fibrosis and fibrosis before decline in function. It is a promising method to detect early development of fibrosis and CKD before progression. 2025-08-08T18:45:54Z 16 pages, 4 figures, 4 tables, 7 page supplementary Mira M. Liu Jonathan Dyke Thomas Gladytz Jonas Jasse Ian Bolger Sergio Calle Swathi Pavuluri Tanner Crews Surya Seshan Steven Salvatore Isaac Stillman Thangamani Muthukumar Bachir Taouli Samira Farouk Octavia Bane Sara Lewis http://arxiv.org/abs/2405.15385v2 CPT-Interp: Continuous sPatial and Temporal Motion Modeling for 4D Medical Image Interpolation 2025-08-08T10:07:51Z Motion information from 4D medical imaging offers critical insights into dynamic changes in patient anatomy for clinical assessments and radiotherapy planning and, thereby, enhances the capabilities of 3D image analysis. However, inherent physical and technical constraints of imaging hardware often necessitate a compromise between temporal resolution and image quality. Frame interpolation emerges as a pivotal solution to this challenge. Previous methods often suffer from discretion when they estimate the intermediate motion and execute the forward warping. In this study, we draw inspiration from fluid mechanics to propose a novel approach for continuously modeling patient anatomic motion using implicit neural representation. It ensures both spatial and temporal continuity, effectively bridging Eulerian and Lagrangian specifications together to naturally facilitate continuous frame interpolation. Our experiments across multiple datasets underscore the method's superior accuracy and speed. Furthermore, as a case-specific optimization (training-free) approach, it circumvents the need for extensive datasets and addresses model generalization issues. 2024-05-24T09:35:42Z This paper has been merged into the new version of arXiv:2405.00430 Xia Li Runzhao Yang Xiangtai Li Antony Lomax Ye Zhang Joachim Buhmann http://arxiv.org/abs/2508.05725v1 Optimizing MV CBCT Imaging Protocols Using NTCP and Secondary Cancer Risk: A Multi-Site Study in Breast, Pelvic, and Head & Neck Radiotherapy 2025-08-07T16:51:46Z Purpose: To evaluate the cumulative radiobiological impact of daily Megavoltage Cone-Beam Computed Tomography (MV-CBCT) imaging dose based on Normal Tissue Complication Probability (NTCP) and Excess Absolute Risk (EAR) of secondary malignancies among radiotherapy patients treated for breast, pelvic, and head and neck cancers. This study investigated whether MV-CBCT imaging dose warrants protocol personalization according to patient age, anatomical treatment site, and organ-specific radiosensitivity. Methods: This retrospective study included cohorts of breast (n=30), pelvic (n=17), and head and neck (n=20) cancer patients undergoing radiotherapy with daily MV-CBCT. Imaging plans using two common protocols (5 MU and 10 MU per fraction) were analyzed. NTCP values were estimated using logistic and Lyman-Kutcher-Burman (LKB) models, while EAR was calculated using Schneider's Organ Equivalent Dose (OED)-based model. Statistical analysis used paired t-tests, and results were further stratified by age (under 40, 40 to 60, over 60 years). Results: In breast cancer patients, NTCP for lung increased significantly under the 10 MU protocol (p<0.001). EAR was elevated in younger breast patients (under 40 years), with some exceeding 15 cases per 10,000 person-years. In pelvic and head and neck groups, NTCP and EAR remained low (under 1 percent), with no clinically meaningful differences between protocols. Across all sites, younger age correlated with higher secondary cancer risk. Conclusion: Daily 10 MU MV-CBCT presents minimal additional risk in pelvic and head and neck radiotherapy. For breast cancer patients under 40, however, it significantly increases secondary cancer risk and lung NTCP. Personalized imaging protocols are recommended based on age, treatment site, and radiosensitivity. 2025-08-07T16:51:46Z Thanh Tai Duong Tien Phat Luong Trung Kien Tran Tuan Linh Duong Ngoc Anh Nguyen Quang Hung Nguyen Peter Sandwall Parham Alaei David Bradley James C. L. Chow http://arxiv.org/abs/2508.05422v1 Look-Up Table-Correction for Beam Hardening-Induced Signal of Clinical Dark-Field Chest Radiographs 2025-08-07T14:14:21Z Background: Material structures at the micrometer scale cause ultra-small-angle X-ray scattering, e.g., seen in lung tissue or plastic foams. In grating-based X-ray imaging, this causes a reduction of the fringe visibility, forming a dark-field signal. Polychromatic beam hardening also changes visibility, adding a false dark-field signal due to attenuation, even in homogeneous, non-scattering materials. Purpose: The objective of this study is to develop a fast, simple, and robust method to correct dark-field signals and bony structures present due to beam hardening on dark-field chest radiographs of study participants. Methods: The method is based on calibration measurements and image processing. Beam hardening by bones and soft tissue is modeled by aluminum and water, respectively, which have no microstructure and thus only generate an artificial dark-field signal. Look-up tables were then created for both. By using a weighted mean of these, forming a single look-up table, and using the attenuation images, the artificial dark-field signal and thus the bone structures present are reduced for study participants. Results: It was found that applying a correction using a weighted look-up table leads to a significant reduction of bone structures in the dark-field image. The weighting of the aluminum component has a substantial impact on the degree to which bone structures remain visible in the dark-field image. Furthermore, a large negative bias in the dark-field image, dependent on the aluminum weighting, was successfully corrected. Conclusions: The beam-hardening-induced signal in the dark-field images was successfully reduced using the method described. The choice of aluminum weighting to suppress rib structures, as well as the selection of bias correction, should be evaluated based on the specific clinical question. 2025-08-07T14:14:21Z Med Phys. 2026; 53:e70307 Maximilian E. Lochschmidt Chair of Biomedical Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich Theresa Urban Chair of Biomedical Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich Lennard Kaster Chair of Biomedical Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich Rafael Schick Chair of Biomedical Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich Thomas Koehler TUM Institute for Advanced Study, Technical University of Munich, Garching, Germany Philips Innovative Technologies, Hamburg, Germany Daniela Pfeiffer Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich TUM Institute for Advanced Study, Technical University of Munich, Garching, Germany Franz Pfeiffer Chair of Biomedical Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich TUM Institute for Advanced Study, Technical University of Munich, Garching, Germany 10.1002/mp.70307 http://arxiv.org/abs/2508.05312v1 Flow-driven magnetic microcatheter for superselective arterial embolization 2025-08-07T12:13:32Z Minimally invasive interventions performed inside brain vessels with the synergistic use of microcatheters pushed over guidewires have revolutionized the way aneurysms, stroke, arteriovenous malformations, brain tumors and other cerebrovascular conditions are being treated. However, a significant portion of the brain vasculature remains inaccessible from within because the conventional catheterization technique based on transmitting forces from the proximal to the distal end of the instruments imposes stringent constraints on their diameter and stiffness. Here we overcome this mechanical barrier by microengineering a new class of ultraminiaturized magnetic microcatheters in the form of an inflatable flat tube, making them extremely flexible and capable of harnessing the kinetic energy of blood flow for endovascular navigation. We introduce a compact and versatile magnetic steering platform that is compatible with conventional bi-plane fluoroscope imaging, and demonstrate for the first time safe and effortless navigation and tracking of hard-to-reach, distal, tortuous arteries that are as small as 180 um in diameter with a curvature radius as small as 0.69 mm. Furthermore, we demonstrate the superselective infusion of contrast and embolic liquid agents, all in a porcine model. These results pave the way to reach, diagnose, and treat currently inaccessible distal arteries that may be at risk of bleeding or feeding a tumor. Our endovascular technology can also be used to selectively target tissues for drug or gene delivery from within the arteries, not only in the central and peripheral nervous system but almost any other organ system, with improved accuracy, speed and safety. 2025-08-07T12:13:32Z Lucio Pancaldi Ece Özelçi Mehdi Ali Gadiri Julian Raub Pascal John Mosimann Mahmut Selman Sakar http://arxiv.org/abs/2506.15803v2 Unsupervised deep learning model for fast energy layer pre-selection of delivery-efficient proton arc therapy plan optimization of nasopharyngeal carcinoma 2025-08-07T08:09:08Z Proton arc therapy (PAT) is an emerging and promising modality in radiotherapy, offering improved dose distribution and treatment robustness over intensity-modulated proton therapy. Yet, identifying the optimal energy layer (EL) sequence remains challenging due to the intensive computational demand and prolonged treatment delivery time. This study proposes an unsupervised deep learning model for fast EL pre-selection that minimizes EL switch (ELS) time while maintaining high plan quality. We introduce a novel data representation method, spot-count representation, which encodes the number of proton spots intersecting the target and organs at risk (OAR) in a matrix structured by sorted gantry angles and energy layers. This representation serves as the input of an U-Net style architecture, SPArc_dl, which is trained using a tri-objective function: maximizing spot-counts on target, minimizing spot-counts on OAR, and reducing ELS time. The model is evaluated on 35 nasopharyngeal cancer cases, and its performance is compared to SPArc_particle_swarm (SPArc_ps). SPArc_dl produces EL pre-selection that significantly improves both plan quality and delivery efficiency. Compared to SPArc_ps, it enhances the conformity index by 0.1 (p<0.01), reduces the homogeneity index by 0.71 (p<0.01), lowers the brainstem mean dose by 0.25 (p<0.01), and shortens the ELS time by 37.2% (p < 0.01). The results unintentionally reveal employing unchanged ELS is more time-wise efficient than descended ELS. SPArc_dl's inference time is within 1 second. However, SPArc_dl plan demonstrates limitation in robustness. The proposed spot-count representation lays a foundation for incorporating unsupervised deep learning approaches into EL pre-selection task. SPArc_dl is a fast tool for generating high-quality PAT plans by strategically pre-selecting EL to reduce delivery time while maintaining excellent dosimetric performance. 2025-06-18T18:40:10Z Bohan Yang Gang Liu Yang Zhong Rirao Dao Yujia Qian Ke Shi Anke Tang Yong Luo Qi Kong Jingnan Liu