https://arxiv.org/api/R9wKxZKbjVjMuh+9aL+EJZqkXpo2026-06-26T11:11:12Z9008106515http://arxiv.org/abs/2508.12741v1A Multi-Resolution Benchmark Framework for Spatial Reasoning Assessment in Neural Networks2025-08-18T09:04:13ZThis paper presents preliminary results in the definition of a comprehensive benchmark framework designed to systematically evaluate spatial reasoning capabilities in neural networks, with a particular focus on morphological properties such as connectivity and distance relationships. The framework is currently being used to study the capabilities of nnU-Net, exploiting the spatial model checker VoxLogicA to generate two distinct categories of synthetic datasets: maze connectivity problems for topological analysis and spatial distance computation tasks for geometric understanding. Each category is evaluated across multiple resolutions to assess scalability and generalization properties. The automated pipeline encompasses a complete machine learning workflow including: synthetic dataset generation, standardized training with cross-validation, inference execution, and comprehensive evaluation using Dice coefficient and IoU (Intersection over Union) metrics. Preliminary experimental results demonstrate significant challenges in neural network spatial reasoning capabilities, revealing systematic failures in basic geometric and topological understanding tasks. The framework provides a reproducible experimental protocol, enabling researchers to identify specific limitations. Such limitations could be addressed through hybrid approaches combining neural networks with symbolic reasoning methods for improved spatial understanding in clinical applications, establishing a foundation for ongoing research into neural network spatial reasoning limitations and potential solutions.2025-08-18T09:04:13ZManuela ImbrianiGina BelmonteMieke MassinkAlessandro TofaniVincenzo Cianciahttp://arxiv.org/abs/2508.12509v1Optimization-based phase retrieval for material decomposition with multi-energy computed tomography2025-08-17T22:00:27ZMulti-energy CT has long demonstrated its ability to enhance image quality with material decomposition. Yet, it has largely been limited to applications that already have high contrast. More recently, x-ray phase-contrast (XPC) imaging has gained interest for its potential to improve detectability in tasks lacking such contrast. Previous work has demonstrated the benefit of combining multi-energy imaging with XPC for material decomposition. While the existing method is promising, its analytical approach requires several approximations that limit its broad applicability, and it is based on projection imaging, requiring separate tomographic reconstruction for three-dimensional (3D) volumes. We propose a natively 3D optimization-based solution that leverages modern computational advances, namely automatic differentiability, to efficiently solve the multi-energy CT phase retrieval problem with a more accurate forward model. In a simulation study, we quantitatively demonstrate the improvement of our proposed technique relative to the existing analytical standard, and we affirm the benefits of phase contrast over traditional absorption-only x-ray imaging.2025-08-17T22:00:27ZPresented at the 18th International Meeting on Fully 3D Image Reconstruction in Radiology and Nuclear Medicine (2025)Giavanna JadickPatrick La Rivièrehttp://arxiv.org/abs/2508.12505v1Accuracy of propagation-based phase-contrast CT under the projection approximation2025-08-17T21:52:10ZX-ray phase-contrast imaging has the potential to improve image contrast with lower dose by probing an object's refractive properties as well as its absorptive properties. To reconstruct a phase-contrast image from a raw dataset, a phase retrieval algorithm must be applied to invert the forward model of the image acquisition scheme. Discrete forward modeling presents unique computational challenges due to high x-ray wave field sampling requirements. At the cost of accuracy, approximations are often applied for the sake of simplicity and experimental convenience. One of the most ubiquitous simplifications is the projection approximation, which neglects refractive effects within an object. The approximation's validity decreases when imaging thicker objects or using a detector with higher spatial resolution. For greater accuracy, one might use the multislice model instead. In this work, we explore the accuracy of the projection approximation in simulated synchrotron micro-CT images. We simulated images using two detector resolutions (0.5 and 2 micron) with either the projection approximation or multislice forward model. Paganin phase retrieval was applied to the resulting datasets, and the final phase-contrast images were reconstructed using filtered back-projection. The 2-micron resolution detector images showed little difference between forward models, indicating the projection approximation is satisfied. With sub-micron resolution, there is a noticeable difference in the phase-contrast images, especially around fine details. An accurate phase retrieval algorithm for such high-resolution data likely requires more detailed forward modeling that avoids making the projection approximation.2025-08-17T21:52:10ZPresented at the 8th International Conference on Image Formation in X-Ray Computed Tomography (2024)Giavanna JadickPatrick La Rivièrehttp://arxiv.org/abs/2508.12451v1Fast silicon detectors as proton therapy beam monitors2025-08-17T17:53:54ZLow Gain Avalanche Detectors (LGADs) are fast silicon sensors with potential for high-resolution proton beam monitoring. In this work, we investigated their response in a 60 MeV proton beam from an AIC-144 cyclotron. Several features of the pulse structure of the cyclotron were observed for the first time. The detector and acquisition system tested was shown to provide accurate flux measurements up to an instantaneous dose rate of about 7.5 Gy/s. Above this, there is an efficiency loss due to multiple protons crossing the detector, which could be addressed through a redesign of the sensors and electronics. LGADs therefore offer a viable alternative for proton therapy beam diagnostics.2025-08-17T17:53:54ZA. BelloraL. GrzankaR. McNultyN. MinafraK. MisanM. NesselT. NowakP. RzeznikJ. SwakonT. Szollosovahttp://arxiv.org/abs/2508.13212v1High-Resolution Directional Depth Electrodes: Open-Source FEM Lead-Field Modeling, Characterization, and Validation2025-08-16T22:31:42ZDepth electrodes used in stereoelectroencephalography (sEEG) and deep-brain stimulation (DBS) are essential tools for neural recording and stimulation. Traditional designs have limited spatial resolution, typically 8 to 16 cylindrical contacts (0.8 to 1.0 mm diameter) along a 5 to 10 cm shaft, restricting recordings from small or localized populations. Recent high-density, directional electrodes (HDsEEG) enable finer localization of local field potentials (LFPs) and spike timing. Yet, characterizing their directional sensitivity and validating modeling tools for lead field (LF) analysis remain critical. We compare finite element method (FEM) LF modeling of a novel HD-sEEG electrode using two tools: a commercial solver (ANSYS) and an open-source pipeline (Brainstorm-DUNEuro). Goals: (i) validate against analytical solutions, (ii) assess solver differences, and (iii) characterize HDsEEG directional sensitivity. LFs were modeled in simple and bio-relevant scenarios. Using Helmholtz reciprocity, we computed LFs by (a) electrode-based stimulation with ANSYS and (b) source-based recording with Brainstorm-DUNEuro. First, a multi-sphere head model with known solutions tested the solver's accuracy. Next, an HDsEEG electrode in a homogeneous conductor was simulated. Directional effects were assessed by comparing sensitivity with vs. without the insulating substrate. Source localization performance was also compared between HDsEEG and standard electrodes. Both solvers closely matched analytic solutions. In realistic settings, LF distributions were highly similar. Modeling showed clear directional sensitivity: contacts facing a source had higher sensitivity than those shadowed, reflecting a substrate shielding effect that vanished when the substrate was conductive. Crucially, HDsEEG improved source localization, as voltage differences across contacts provided robust directional LF information.2025-08-16T22:31:42Z20 pages, 12 figuresTakfarinas MedaniJace WillisChris WrightYash VakilnaRyan ShoresRaymundo CassaniAnand JoshiRichard LeahyJohn SeymourJohn Mosherhttp://arxiv.org/abs/2508.13206v1Fine-Tuning Hydrophilic-Hydrophobic Balance in Stimuli-Responsive PEGPNIPAM Micelles for Controlled Drug Delivery2025-08-16T07:56:18ZTemperature-responsive polymeric micelles have great potential in drug delivery, enhancing therapeutic efficacy while minimizing systemic toxicity. This study investigates the self-assembly of poly(ethylene glycol)-poly(N-isopropylacrylamide) (PEG-PNIPAM) block copolymers as nanocarriers for Doxorubicin (DOX) using coarse-grained molecular dynamics (CG-MD) simulations. We systematically examined the effects of polymer chain length and hydrophilic/hydrophobic balance on micelle formation, stability, and drug encapsulation efficiency. PEG-PNIPAM copolymers self-assembled above the lower critical solution temperature (LCST), forming stable micelles with varying morphologies. Our findings revealed that PEG enhances micelle hydration and stability, while PNIPAM improves drug retention but may hinder controlled release. Increasing PNIPAM or PEG length significantly increased micelle size, with DOX preferentially localizing in the PEG-rich outer shell, enhancing solubility and preventing aggregation. The DOX diffusion coefficient ranged from $10^{-8}$ to $10^{-9}$ cm$^{2}$s$^{-1}$, reflecting drug release dynamics. Structural and thermodynamic analyses confirmed spontaneous DOX encapsulation, with PEG-PNIPAM micelles providing a favorable environment for drug loading. Mean square displacement (MSD), radial distribution function (RDF), and solvent-accessible surface area (SASA) analyses highlighted the role of PEG in controlled drug release and PNIPAM in drug binding. These molecular-level insights underscore the potential of fine-tuning PEG-PNIPAM compositions for enhanced drug delivery, paving the way for precision cancer therapies.2025-08-16T07:56:18ZJournal of Molecular Liquids, 436, 2025Ghazal JamiradMahdi SeifAbbas Montazeri10.1016/j.molliq.2025.128239http://arxiv.org/abs/2504.20698v2A High-Granularity Proton CT Enhanced by Track Discrimination2025-08-16T03:11:47ZProton Computed Tomography (pCT) provides a promising solution to enhance the accuracy of Relative Stopping Power (RSP) required for proton therapy planning. This research introduces a novel high-granularity pCT architecture that incorporates a silicon pixel tracking system and a calorimetric range telescope, which uniquely integrates range telescope functionality with track discrimination capabilities. The Bortfeld function fitting and Convolutional Neural Network (CNN) classifier algorithms are developed and applied for discrimination. In simulation studies, both approaches demonstrate the capability to reduce uncertainty in Water Equivalent Path Length (WEPL) determination for individual proton tracks to below 3~mm. The standard imaging protocol (3.2~mGy, $4\times10^{8}$ protons) achieves sub-millimeter spatial resolution ($\sim$0.5 mm) with sub-1\% RSP accuracy. With proton count requirements reduced by track discrimination, an ultra-low-dose protocol (0.16~mGy, $2\times10^{7}$~protons) is proposed with achieved sub-1\% RSP accuracy and $\sim$1.1~mm spatial resolution in simulation. This low-dose performance significantly expands clinical applicability, particularly for pediatric imaging or frequent imaging scenarios. Furthermore, the target 10 MHz proton detection rate suggests potential for real-time image guidance during radiotherapy. By circumventing the need for ultra-precise energy measurements, this design minimizes hardware complexity and provides a scalable foundation for future pCT systems.2025-04-29T12:29:12Z11 pages, 8 figures, 3 tablesHuang-Chao ShiDan-Qi WangMei-Qi LiuYi-Dong YangBao-Hua QiYong LiuYang-Hui QinChang-Qing FengYi LiuHong-Bo Zhuhttp://arxiv.org/abs/2508.10625v1Beam Hardening Correction in Clinical X-ray Dark-Field Chest Radiography using Deep Learning-Based Bone Segmentation2025-08-14T13:25:12ZDark-field radiography is a novel X-ray imaging modality that enables complementary diagnostic information by visualizing the microstructural properties of lung tissue. Implemented via a Talbot-Lau interferometer integrated into a conventional X-ray system, it allows simultaneous acquisition of perfectly temporally and spatially registered attenuation-based conventional and dark-field radiographs. Recent clinical studies have demonstrated that dark-field radiography outperforms conventional radiography in diagnosing and staging pulmonary diseases. However, the polychromatic nature of medical X-ray sources leads to beam-hardening, which introduces structured artifacts in the dark-field radiographs, particularly from osseous structures. This so-called beam-hardening-induced dark-field signal is an artificial dark-field signal and causes undesired cross-talk between attenuation and dark-field channels. This work presents a segmentation-based beam-hardening correction method using deep learning to segment ribs and clavicles. Attenuation contribution masks derived from dual-layer detector computed tomography data, decomposed into aluminum and water, were used to refine the material distribution estimation. The method was evaluated both qualitatively and quantitatively on clinical data from healthy subjects and patients with chronic obstructive pulmonary disease and COVID-19. The proposed approach reduces bone-induced artifacts and improves the homogeneity of the lung dark-field signal, supporting more reliable visual and quantitative assessment in clinical dark-field chest radiography.2025-08-14T13:25:12ZLennard KasterMaximilian E. LochschmidtAnne M. BauerTina DorostiSofia DemianovaThomas KoehlerDaniela PfeifferFranz Pfeifferhttp://arxiv.org/abs/2508.10596v1A Unified Framework from Boltzmann Transport to Proton Treatment Planning2025-08-14T12:37:25ZThis work develops a rigorous mathematical formulation of proton transport by integrating both deterministic and stochastic perspectives. The deterministic framework is based on the Boltzmann-Fokker-Planck equation, formulated as an operator equation in a suitable functional setting. The stochastic approach models proton evolution via a track-length parameterised diffusion process, whose infinitesimal generator provides an alternative description of transport.
A key result is the duality between the stochastic and deterministic formulations, established through the adjoint relationship between the transport operator and the stochastic generator. We prove that the resolvent of the stochastic process corresponds to the Green's function of the deterministic equation, providing a natural link between fluence-based and particle-based transport descriptions. The theory is applied to dose computation, where we show that the classical relation: dose = (fluence * mass stopping power) arises consistently in both approaches.
Building on this foundation, we formulate a hybrid optimisation framework for treatment planning, in which dose is computed using a stochastic model while optimisation proceeds via adjoint-based PDE methods. We prove existence and differentiability of the objective functional and derive the first-order optimality system. This framework bridges stochastic simulation with deterministic control theory and provides a foundation for future work in constrained, adaptive and uncertainty-aware optimisation in proton therapy.2025-08-14T12:37:25Z23 pages, 3 figuresAndreas E. KyprianouAaron PimTristan Pryerhttp://arxiv.org/abs/2508.10205v1Coaxial Dipole Array with Switching Transmit Sensitivities for ultrahigh field MRI2025-08-13T21:32:32ZPurpose: To investigate dipole antennas with electronically switchable transmit field patterns to improve flip angle homogeneity in ultra-high field MRI
Methods: An array of eight coaxial dipoles with electronically switchable $B_{1}^{\!+}$ field profiles was constructed. Alteration of the field profiles was accomplished by modulating the currents along the dipoles using a combination of PIN diodes and lumped inductances. The behavior of these reconfigurable elements was studied in numerical electromagnetic simulations and 9.4T MRI measurements, investigating rapid switching of transmit sensitivities during excitation pulses in both single-channel and pTx mode operation.
Results: For the simulated dipole elements, modulating the current densities along the dipole's axis causes a $\sim$30% change of the $B_{1}^{\!+}$ field between superior and inferior regions of the brain. When rapidly switched during excitation pulses, this degree of freedom can improve flip angle homogeneity, e.g. by a factor of $\sim$2.2 for a two kT points pTx pulse. For the constructed prototype array, the switching effect was observable but weaker, causing $\sim$10% superior-inferior $B_{1}^{\!+}$ variation.
Conclusion: The proposed coaxial dipole array with switchable transmit sensitivities offers a novel degree of freedom for designing excitation pulses. The approach has the potential to improve flip angle homogeneity without necessitating an expensive increase in the number of independent transmit channels.2025-08-13T21:32:32Zsubmitted to Magnetic Resonance in Medicine for consideration as a Technical NoteDario BoschGeorgiy A. SolomakhaFelix GlangMartin FreudensprungNikolai I. AvdievichKlaus Schefflerhttp://arxiv.org/abs/2508.10188v1In Silico Evaluation of Cardiac Tissue-Engineered Patch Interventions2025-08-13T20:47:25ZMyocardial infarction significantly degrades heart function, and current treatments can bring forth serious cost and complications including blood clots and infections. To improve the current state of treatment, researchers are developing tissue patches from induced-pluripotent stem cells that can be incorporated into the heart, improving organ function after a myocardial infarction. These tissue patches include surface patches, attached to the epicardium of the heart, and thick transmural patches that replace the infarcted region. However, little is known about the impact of cardiac tissue patches on pump function in a patient's heart. In addition, it is not clear what patch structural properties - such as active stress generation, muscle fiber alignment, or material stiffness - may best augment existing heart tissue. Computational modeling can be used to examine different implementations and patch properties, illuminating the mechanical impact of cardiac tissue patches in the beating heart. In this work, we computationally implement different cardiac tissue patches to understand benefits of particular patch types and properties. We find that in transmural cardiac tissue patches, both activation and fiber alignment improve function. A transmural patch generating 10% of healthy active stress can increase stroke volume by 18%, and higher generated active stress in a circumferential muscle fiber orientation can recover stroke volume by over 50%. Furthermore, we find that surface cardiac tissue patches can enhance heart function slightly despite limiting diastolic filling, especially when fibrotic thinning has occurred. These conclusions identify broad design goals for the engineering of cardiac tissue patches to improve heart function after a myocardial infarction.2025-08-13T20:47:25Z28 pages, 9 figures. Date: August 13, 2025Computers in Biology and Medicine, Volume 198, Part B, 2025, 111249John Patrick Sayut,Javiera JilbertoMia BoniniMarc HirschvogelWill ZhangDavid A. Nordsletten10.1016/j.compbiomed.2025.111249http://arxiv.org/abs/2508.10184v1MIMOSA: Multi-parametric Imaging using Multiple-echoes with Optimized Simultaneous Acquisition for highly-efficient quantitative MRI2025-08-13T20:38:50ZPurpose: To develop a new sequence, MIMOSA, for highly-efficient T1, T2, T2*, proton density (PD), and source separation quantitative susceptibility mapping (QSM). Methods: MIMOSA was developed based on 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) by combining 3D turbo Fast Low Angle Shot (FLASH) and multi-echo gradient echo acquisition modules with a spiral-like Cartesian trajectory to facilitate highly-efficient acquisition. Simulations were performed to optimize the sequence. Multi-contrast/-slice zero-shot self-supervised learning algorithm was employed for reconstruction. The accuracy of quantitative mapping was assessed by comparing MIMOSA with 3D-QALAS and reference techniques in both ISMRM/NIST phantom and in-vivo experiments. MIMOSA's acceleration capability was assessed at R = 3.3, 6.5, and 11.8 in in-vivo experiments, with repeatability assessed through scan-rescan studies. Beyond the 3T experiments, mesoscale quantitative mapping was performed at 750 um isotropic resolution at 7T. Results: Simulations demonstrated that MIMOSA achieved improved parameter estimation accuracy compared to 3D-QALAS. Phantom experiments indicated that MIMOSA exhibited better agreement with the reference techniques than 3D-QALAS. In-vivo experiments demonstrated that an acceleration factor of up to R = 11.8-fold can be achieved while preserving parameter estimation accuracy, with intra-class correlation coefficients of 0.998 (T1), 0.973 (T2), 0.947 (T2*), 0.992 (QSM), 0.987 (paramagnetic susceptibility), and 0.977 (diamagnetic susceptibility) in scan-rescan studies. Whole-brain T1, T2, T2*, PD, source separation QSM were obtained with 1 mm isotropic resolution in 3 min at 3T and 750 um isotropic resolution in 13 min at 7T. Conclusion: MIMOSA demonstrated potential for highly-efficient multi-parametric mapping.2025-08-13T20:38:50Z48 pages, 21 figures, 3 tablesYuting ChenYohan JunAmir HeydariXingwang YongJiye KimJongho LeeHuafeng LiuHuihui YeBorjan GagoskiShohei FujitaBerkin Bilgichttp://arxiv.org/abs/2508.10134v1Patient-Specific 3D Printed Dynamic Preoperative Planning Models in Modern Medicine2025-08-13T18:57:17ZThree-dimensional (3D) printed preoperative planning models serve a critical role in the success of many medical procedures. However, many of these models do not portray the patient's complete anatomy due to their monolithic and static nature. The use of dynamic 3D-printed models can better equip physicians by providing a more anatomically accurate model due to its movement capabilities and the ability to remove and replace printed anatomies based on planning stages. A dynamic 3D-printed preoperative planning model has the capability to move in similar ways to the anatomy that is being represented by the model, or reveal additional issues that may arise during the use of a movement mechanism. The 3D-printed models are constructed in a similar manner to their static counterparts; however, in the digital post-processing phase, additional care is needed to ensure the dynamic functionality of the model. Here, we discuss the process of creating a dynamic 3D-printed model and its benefits and uses in modern medicine.2025-08-13T18:57:17Z8 pages, 3 figuresKeshav JhaJoseph Mayerhttp://arxiv.org/abs/2504.16600v23D-1D modelling of cranial mesh heating induced by low or medium frequency magnetic fields2025-08-13T13:48:54ZSafety assessment of patients with one-dimensionally structured passive implants, like cranial meshes or stents, exposed to low or medium frequency magnetic fields, like those generated in magnetic resonance imaging or magnetic hyperthermia, can be challenging, because of the different length scales of the implant and the human body. Most of the methods used to estimate the heating induced near such implants neglect the presence of the metallic materials within the body, modeling the metal as thermal seeds. To overcome this limitation, a novel numerical approach that solves three-dimensional and one-dimensional coupled problems is proposed. The proposed method is compared with measurements performed on a cranial mesh exposed to the magnetic field generated by a gradient coil system for magnetic resonance imaging. Then, it is applied to a magnetic hyperthermia case study in which a patient with a cranial mesh is exposed to the magnetic field generated by a collar-type magnetic hyperthermia applicator for neck tumour treatment. The experimental comparison of the proposed method predictions and the measurement data shows an improved accuracy near the maximum temperature increase up to 25% with respect to the method based on thermal seeds. The application of the proposed method applied to the magnetic hyperthermia case study leads to a prediction of the maximum temperature increase that is 10% lower than the one overestimated by relying on thermal seeds. At the same time, the proposed method corrects the underestimation of the thermal seeds in the regions where the electromagnetic power is not directly deposited and the temperature increase is only due to heat transfer. The proposed method leads to improved results with respect to previous approximations by modelling the thermal diffusion through the highly conductive metallic implants.2025-04-23T10:29:53Z20 pages, 7 figuresA. Arduino, et al, "3D-1D modelling of cranial mesh heating induced by low or medium frequency magnetic fields," Computer Methods and Programs in Biomedicine (2025) Vol. 271, Art. no. 109009Alessandro ArduinoOriano BottauscioDenise GrappeinStefano ScialóFabio ViciniUmberto ZanovelloLuca Zilberti10.1016/j.cmpb.2025.109009http://arxiv.org/abs/2508.09675v1Time-Domain Reconstruction of the Speed of Sound in Ring-Array Ultrasound Computed Tomography with Randomized Super-Shots2025-08-13T10:07:35ZRing-array ultrasound computed tomography has recently achieved sufficient maturity for clinical applications like breast imaging. Image reconstruction is achieved with state of art iterative algorithms (full waveform inversion in the frequency domain). In this Letter, we consider a stochastic reconstruction in the time-domain. We introduce the notion of multiple super-shots and stochastic ensembles and test our inversion algorithm on publicly available experimental data. Our results show that image quality of a time-domain stochastic reconstruction may be comparable to image quality of a deterministic reconstruction in the frequency-domain, although the time-domain reconstruction is significantly slower.2025-08-13T10:07:35ZLuca A. Forte