https://arxiv.org/api/EumL+hs02scMPIXDPclphA0ZfY0 2026-06-26T09:48:35Z 9008 1050 15 http://arxiv.org/abs/2508.15163v1 Non-invasive Assessment of Pancreatic Duct Hypertension Using Computational Flow Modeling 2025-08-21T02:01:49Z Chronic pancreatitis (CP) is a progressive inflammatory disease frequently associated with severe, treatment-resistant abdominal pain, which is hypothesized to result from pancreatic ductal hypertension (PDH) secondary to ductal strictures or obstructions. However, direct measurement of pancreatic duct pressure (PDP) remains technically demanding and invasive, thereby significantly limiting its routine clinical application. Here, we propose and validate a novel, non-invasive approach for estimating PDP. The method integrates patient-specific magnetic resonance cholangiopancreatography (MRCP) imaging with computational fluid dynamics (CFD) modeling. Three-dimensional ductal models reconstructed from MRCP data enabled simulation of intraductal pressure distributions with high anatomical fidelity. The simulated pressure gradients showed strong correlation with in vivo measurements obtained via endoscopic retrograde cholangiopancreatography (ERCP), as well as with clinical outcomes such as pain relief following ductal decompression. To improve clinical usability, we developed a quasi-one-dimensional analytical model that accurately predicted PDP from ductal geometry and flow parameters, showing strong concordance with CFD results. These findings establish the feasibility and clinical relevance of MRCP-based PDP estimation, and underscore its potential as a non-invasive diagnostic tool for detecting PDH and informing therapeutic decisions in patients with CP. 2025-08-21T02:01:49Z 26 pages, 8 figures Haobo Zhao Jung-Hee Seo Venkata Akshintala Surya Evani Rajat Mittal http://arxiv.org/abs/2508.15867v1 Turbo Spin Echo Imaging at 7T with Bilateral Orthogonality Generative Acquisitions Method for Homogeneous T_1, T_2 and Proton Density Contrasts 2025-08-20T23:57:15Z Purpose: Bilateral Orthogonality Generative Acquisitions (BOGA) method, which was initially implemented for T_2^* contrast via gradient echo acquisitions, is adapted for TSE imaging at 7T using parallel transmission (pTx) system for obtaining homogeneous T_1, T_2 and proton density weighted images. Theory and Methods: Multiple TSE images with complimentary RF modes and scan parameters are acquired as input images for the BOGA method where RF modes have complimentary transmit and receive field inhomogeneity patterns and scan parameters have varying echo and repetition times. With the application of the BOGA method using different subsets of the data acquisitions for each contrast, homogeneous T_1, T_2 and proton density contrast in the final images obtained. Furthermore, to demonstrate the effect of the TSE factor, two TSE factors are used individually. Normalized intensity profiles and signal to noise ratio maps are utilized for the comparison of the CP mode images and the TSE factors respectively. Results: Homogeneous T_1, T_2 and proton density weighted images are obtained with the TSE implementation of the BOGA method without the transmit and receive field inhomogeneity effects. Furthermore, mixed contrast effects of the TSE acquisition are simultaneously resolved independently of the TSE factor. Conclusion: TSE application of BOGA method results in homogeneous T_1, T_2 and proton density contrasts at 7T, as the inhomogeneity effects are removed from the final contrast without any prior data acquisitions. 2025-08-20T23:57:15Z Celik Boga Anke Henning http://arxiv.org/abs/2508.14824v1 Calibration offset estimation in mobile hearing tests via categorical loudness scaling 2025-08-20T16:17:06Z Objective: To enable reliable smartphone-based hearing assessments by developing methods to estimate device calibration offsets using categorical loudness scaling (CLS). Design: Calibration offsets were simulated from a Gaussian distribution. Two prediction models - a Bayesian regression model and a nearest neighbor model - were trained on CLS-derived parameters and data from the Oldenburg Hearing Health Repository (OHHR). CLS was chosen because it provides level-independent measures (e.g., dynamic range) that remain robust despite calibration errors. Study Sample: The dataset comprised CLS results from N = 847 participants with a mean age of 70.0 years (SD = 8.7), including 556 male and 291 female listeners with diverse hearing profiles. Results: The Bayesian regression model achieved correlations of up to 0.81 between estimated and true calibration offsets, enabling accurate individual-level correction. Compared to threshold-based approaches, calibration uncertainty was reduced by factors between 0.41 and 0.79, demonstrating greater robustness in uncontrolled environments. Conclusions: CLS-based models can effectively compensate for missing calibration in mobile hearing assessments. This approach provides a practical alternative to threshold-based methods, supporting the use of smartphone-based tests outside laboratory settings and expanding access to reliable hearing healthcare in everyday and resource-limited contexts. 2025-08-20T16:17:06Z Chen Xu Birger Kollmeier 10.1080/14992027.2026.2663342 http://arxiv.org/abs/2507.11317v2 Species-Dependent Electron Emission from Nanoparticles under Gamma Irradiation 2025-08-20T08:32:11Z In this study, various nanoparticle species-including Au and Gd$_2$O$_3$-were irradiated with low-energy gamma rays, such as 59.5 keV photons from $^{241}$Am. Pulse-height spectra were recorded using a liquid-scintillation counting system before and after dispersing the nanoparticles into the scintillator, and the differences between them were analyzed to infer the interaction outcomes. Gd$_2$O$_3$ nanoparticles emitted numerous electrons; however, under identical experimental conditions, no detectable electron emission was observed from Au nanoparticles (AuNPs). Here, "detectable electron emission" refers to electrons with energies high enough to be registered by the liquid-scintillation detector used (approx 100 eV and, more typically, >= 1-2 keV); however, it excludes electrons that may be emitted at lower energies. Thus, a species-dependent radiation-nanoparticle interaction was observed. Rigorous controls and falsification tests excluded various artefacts-including detector insensitivity, surface contamination, aggregation, quenching, and self-absorption-as causes for the absence of detectable electron emission from AuNPs. This observation potentially prompts a re-evaluation of the common assumption that nanoparticles behave like their bulk counterparts and emit electrons upon gamma-irradiation. Instead, our results suggest that the distinct internal environment of nanoparticles influences their interaction with radiation. These findings offer significant insights for practical applications, including a better mechanistic understanding of nanoparticle radiosensitization in cancer therapy, enhanced gamma-detection efficiency of organic scintillators, and the development of lightweight radiation shields. 2025-07-15T13:49:03Z Version 2 (Uncertainty and Error Analysis are brought together in one place). Comments are welcome Darukesha B H M http://arxiv.org/abs/2508.14364v1 Physics-Constrained Diffusion Reconstruction with Posterior Correction for Quantitative and Fast PET Imaging 2025-08-20T02:39:55Z Deep learning-based reconstruction of positron emission tomography(PET) data has gained increasing attention in recent years. While these methods achieve fast reconstruction,concerns remain regarding quantitative accuracy and the presence of artifacts,stemming from limited model interpretability,data driven dependence, and overfitting risks.These challenges have hindered clinical adoption.To address them,we propose a conditional diffusion model with posterior physical correction (PET-DPC) for PET image reconstruction. An innovative normalization procedure generates the input Geometric TOF Probabilistic Image (GTP-image),while physical information is incorporated during the diffusion sampling process to perform posterior scatter,attenuation,and random corrections. The model was trained and validated on 300 brain and 50 whole-body PET datasets,a physical phantom,and 20 simulated brain datasets. PET-DPC produced reconstructions closely aligned with fully corrected OSEM images,outperforming end-to-end deep learning models in quantitative metrics and,in some cases, surpassing traditional iterative methods. The model also generalized well to out-of-distribution(OOD) data. Compared to iterative methods,PET-DPC reduced reconstruction time by 50% for brain scans and 85% for whole-body scans. Ablation studies confirmed the critical role of posterior correction in implementing scatter and attenuation corrections,enhancing reconstruction accuracy. Experiments with physical phantoms further demonstrated PET-DPC's ability to preserve background uniformity and accurately reproduce tumor-to-background intensity ratios. Overall,these results highlight PET-DPC as a promising approach for rapid, quantitatively accurate PET reconstruction,with strong potential to improve clinical imaging workflows. 2025-08-20T02:39:55Z Yucun Hou Fenglin Zhan Chenxi Li Ziquan Yuan Haoyu Lu Yue Chen Yihao Chen Kexin Wang Runze Liao Haoqi Wen Ganxi Du Jiaru Ni Taoran Chen Jinyue Zhang Jigang Yang Jianyong Jiang http://arxiv.org/abs/2508.14363v1 Multimodal concentric surface coils for enhanced sensitivity in MR imaging 2025-08-20T02:23:37Z This study presents the design, simulation, and experimental validation of a novel multimodal concentric surface coil for MR imaging, developed to achieve higher B1 field efficiency while maintaining low SAR for enhanced imaging performance. The coil comprises multiple electromagnetically coupled concentric resonators of varying sizes. The resonant frequency of a desired mode is tuned to 127 MHz, as an example, to demonstrate the performance of the proposed technique at 3 Tesla. Fullwave electromagnetic simulations of the proposed design and bench tests of fabricated prototypes were conducted to evaluate the coil's B1 field efficiency and distribution, multimodal resonance behavior, scattering parameters, and SAR performance. Inductive Current Elimination or magnetic wall decoupling was implemented to enhance channel isolation in a multi channel configuration to demonstrate the feasibility of applying this multimodal technique to RF array design and parallel imaging. Experimental results show that the proposed concentric coil achieves higher B1 field efficiency and reduced SAR compared to a conventional surface coil of the same size operating at 3 Tesla. Bench measurements on the prototypes confirmed successful tuning and impedance matching, with measured S11 and S21 parameters validating the effectiveness of the decoupling strategy. B1 mapping experiments further demonstrated efficient RF power delivery across multiple planes. These findings suggest that the proposed multimodal concentric coil has the potential to serve as a promising alternative to conventional surface coils for high performance MR imaging, offering enhanced RF efficiency, reduced SAR, and the ability to construct multichannel RF arrays. 2025-08-20T02:23:37Z Yunkun Zhao Aditya A Bhosale Xiaoliang Zhang http://arxiv.org/abs/2409.05680v2 Cherenkov Imaged Bio-morphological Features Verify Patient Positioning with Deformable Tissue Translocation in Breast Radiotherapy 2025-08-19T20:11:45Z Accurate patient positioning is critical for precise radiotherapy dose delivery, as positioning errors can significantly affect treatment outcomes. This study introduces a novel method for tracking loco-regional tissue deformation through Cherenkov image analysis during fractionated breast cancer radiotherapy. The primary goal was to develop and test an algorithm for Cherenkov-based regional position accuracy quantification, specifically for loco-regional deformations, which lack ideal quantification methods in radiotherapy. Blood vessel detection and segmentation were developed in Cherenkov images using a tissue phantom with incremental movements, and later applied to images from fractionated whole breast radiotherapy in human patients (n=10). A combined rigid and non-rigid registration technique was used to detect inter- and intra-fractional positioning variations. This approach quantified positioning variations in two parts: a global shift from rigid registration and a two-dimensional variation map of loco-regional deformation from non-rigid registration. The methodology was validated using an anthropomorphic chest phantom experiment, where known treatment couch translations and respiratory motion were simulated to assess inter- and intra-fractional uncertainties, yielding an average accuracy of 0.83 mm for couch translations up to 20 mm. Analysis of clinical Cherenkov data from ten breast cancer patients showed an inter-fraction setup variation of 3.7 plus minus 2.4 mm relative to the first fraction and loco-regional deformations (95th percentile) of up to 3.3 plus minus 1.9 mm. This study presents a Cherenkov-based approach to quantify global and local positioning variations, demonstrating feasibility in addressing loco-regional deformations that conventional imaging techniques fail to capture. 2024-09-09T14:48:07Z 25 pages, 4 figures, 1 table, journal under review Yao Chen Savannah M. Decker Petr Bruza David J. Gladstone Lesley A. Jarvis Brian W. Pogue Kimberley S. Samkoe Rongxiao Zhang 10.1016/j.adro.2024.101684 http://arxiv.org/abs/2508.14229v1 New Insights into Automatic Treatment Planning for Cancer Radiotherapy Using Explainable Artificial Intelligence 2025-08-19T19:38:16Z Objective: This study aims to uncover the opaque decision-making process of an artificial intelligence (AI) agent for automatic treatment planning. Approach: We examined a previously developed AI agent based on the Actor-Critic with Experience Replay (ACER) network, which automatically tunes treatment planning parameters (TPPs) for inverse planning in prostate cancer intensity modulated radiotherapy. We selected multiple checkpoint ACER agents from different stages of training and applied an explainable AI (EXAI) method to analyze the attribution from dose-volume histogram (DVH) inputs to TPP-tuning decisions. We then assessed each agent's planning efficacy and efficiency and evaluated their policy and final TPP tuning spaces. Combining these analyses, we systematically examined how ACER agents generated high-quality treatment plans in response to different DVH inputs. Results: Attribution analysis revealed that ACER agents progressively learned to identify dose-violation regions from DVH inputs and promote appropriate TPP-tuning actions to mitigate them. Organ-wise similarities between DVH attributions and dose-violation reductions ranged from 0.25 to 0.5 across tested agents. Agents with stronger attribution-violation similarity required fewer tuning steps (~12-13 vs. 22), exhibited a more concentrated TPP-tuning space with lower entropy (~0.3 vs. 0.6), converged on adjusting only a few TPPs, and showed smaller discrepancies between practical and theoretical tuning steps. Putting together, these findings indicate that high-performing ACER agents can effectively identify dose violations from DVH inputs and employ a global tuning strategy to achieve high-quality treatment planning, much like skilled human planners. Significance: Better interpretability of the agent's decision-making process may enhance clinician trust and inspire new strategies for automatic treatment planning. 2025-08-19T19:38:16Z 19 pages, 7 figures, 1 table, Oral presentation at the conference 'American Association of Physicists in Medicine 2025, 67th Annual Meeting and Exhibition' Md Mainul Abrar Xun Jia Yujie Chi http://arxiv.org/abs/2507.03341v2 UltraDfeGAN: Detail-Enhancing Generative Adversarial Networks for High-Fidelity Functional Ultrasound Synthesis 2025-08-19T15:26:02Z Functional ultrasound (fUS) is a neuroimaging technique known for its high spatiotemporal resolution, enabling non-invasive observation of brain activity through neurovascular coupling. Despite its potential in clinical applications such as neonatal monitoring and intraoperative guidance, the development of fUS faces challenges related to data scarcity and limitations in generating realistic fUS images. This paper explores the use of a generative adversarial network (GAN) framework tailored for fUS image synthesis. The proposed method incorporates architectural enhancements, including feature enhancement modules and normalization techniques, aiming to improve the fidelity and physiological plausibility of generated images. The study evaluates the performance of the framework against existing generative models, demonstrating its capability to produce high-quality fUS images under various experimental conditions. Additionally, the synthesized images are assessed for their utility in downstream tasks, showing improvements in classification accuracy when used for data augmentation. Experimental results are based on publicly available fUS datasets, highlighting the framework's effectiveness in addressing data limitations. 2025-07-04T07:00:41Z Zhuo Li Xuhang Chen Shuqiang Wang Bin Yuan Nou Sotheany Ngeth Rithea http://arxiv.org/abs/2508.13914v1 Development of a defacing algorithm to protect the privacy of head and neck cancer patients in publicly-accessible radiotherapy datasets 2025-08-19T15:14:16Z Introduction: The rise in public medical imaging datasets has raised concerns about patient reidentification from head CT scans. However, existing defacing algorithms often remove or distort Organs at Risk (OARs) and Planning Target Volumes (PTVs) in head and neck cancer (HNC) patients, and ignore DICOM-RT Structure Set and Dose data. Therefore, we developed and validated a novel automated defacing algorithm that preserves these critical structures while removing identifiable features from HNC CTs and DICOM-RT data. Methods: Eye contours were used as landmarks to automate the removal of CT pixels above the inferior-most eye slice and anterior to the eye midpoint. Pixels within PTVs were retained if they intersected with the removed region. The body contour and dose map were reshaped to reflect the defaced image. We validated our approach on 829 HNC CTs from 622 patients. Privacy protection was evaluated by applying the FaceNet512 facial recognition algorithm before and after defacing on 3D-rendered CT pairs from 70 patients. Research utility was assessed by examining the impact of defacing on autocontouring performance using LimbusAI and analyzing PTV locations relative to the defaced regions. Results: Before defacing, FaceNet512 matched 97% of patients' CTs. After defacing, this rate dropped to 4%. LimbusAI effectively autocontoured organs in the defaced CTs, with perfect Dice scores of 1 for OARs below the defaced region, and excellent scores exceeding 0.95 for OARs on the same slices as the crop. We found that 86% of PTVs were entirely below the cropped region, 9.1% were on the same slice as the crop without overlap, and only 4.9% extended into the cropped area. Conclusions: We developed a novel defacing algorithm that anonymizes HNC CT scans and related DICOM-RT data while preserving essential structures, enabling the sharing of HNC imaging datasets for Big Data and AI. 2025-08-19T15:14:16Z 22 pages, 6 figures, submitted to Medical Physics Med Phys. 2025; 52:e70160 Kayla O'Sullivan-Steben Luc Galarneau John Kildea 10.1002/mp.70160 http://arxiv.org/abs/2410.06129v4 Algebraic Methods and Computational Strategies for Pseudoinverse-Based MR Image Reconstruction (Pinv-Recon) 2025-08-19T13:35:13Z Image reconstruction in Magnetic Resonance Imaging (MRI) is fundamentally a linear inverse problem, such that the image can be recovered via explicit pseudoinversion of the encoding matrix by solving $\textbf{data} = \textbf{Encode} \times \textbf{image}$ - a method referred to here as Pinv-Recon. While the benefits of this approach were acknowledged in early studies, the field has historically favored fast Fourier transforms (FFT) and iterative techniques due to perceived computational limitations of the pseudoinversion approach. This work revisits Pinv-Recon in the context of modern hardware, software, and optimized linear algebra routines. We compare various matrix inversion strategies, assess regularization effects, and demonstrate incorporation of advanced encoding physics into a unified reconstruction framework. While hardware advances have already significantly reduced computation time compared to earlier studies, our work further demonstrates that leveraging Cholesky decomposition leads to a two-order-of-magnitude improvement in computational efficiency over previous Singular Value Decomposition-based implementations. Moreover, we demonstrate the versatility of Pinv-Recon on diverse $\textit{in vivo}$ datasets encompassing a range of encoding schemes, starting with low- to medium-resolution functional and metabolic imaging and extending to high-resolution cases. Our findings establish Pinv-Recon as a versatile and robust reconstruction framework that aligns with the increasing emphasis on open-source and reproducible MRI research. 2024-10-08T15:31:41Z 31 pages, 9 figures (+ Supplementary Material). Revised submission to Scientific Reports Kylie Yeung Christine Tobler Rolf F Schulte Benjamin White Anthony McIntyre Sebastien Serres Peter Morris Dorothee Auer Fergus V Gleeson Damian J Tyler James T Grist Florian Wiesinger http://arxiv.org/abs/2410.09523v2 Functional Ultrasound Imaging Combined with Machine Learning for Whole-Brain Analysis of Drug-Induced Hemodynamic Changes 2025-08-19T12:35:46Z Functional ultrasound imaging (fUSI) is a cutting-edge technology that measures changes in cerebral blood volume (CBV) by detecting backscattered echoes from red blood cells moving within its field of view (FOV). It offers high spatiotemporal resolution and sensitivity, allowing for detailed visualization of cerebral blood flow dynamics. While fUSI has been utilized in preclinical drug development studies to explore the mechanisms of action of various drugs targeting the central nervous system, many of these studies rely on predetermined regions of interest (ROIs). This focus may overlook relevant brain activity outside these specific areas, which could influence the results. To address this limitation, we compared three machine learning approaches-convolutional neural network (CNN), support vector machine (SVM), and vision transformer (ViT)-combined with fUSI to analyze the pharmacodynamics of Dizocilpine (MK-801), a potent non-competitive NMDA receptor antagonist commonly used in preclinical models for memory and learning impairments. While all three machine learning techniques could distinguish between drug and control conditions, CNN proved particularly effective due to their ability to capture hierarchical spatial features while maintaining anatomical specificity. Class activation mapping revealed brain regions, including the prefrontal cortex and hippocampus, that are significantly affected by drug administration, consistent with the literature reporting a high density of NMDA receptors in these areas. Overall, the combination of fUSI and CNN creates a novel analytical framework for examining pharmacological mechanisms, allowing for data-driven identification and regional mapping of drug effects while preserving anatomical context and physiological relevance. 2024-10-12T12:57:06Z 24 pages, 6 figures Jared Deighton Shan Zhong Kofi Agyeman Wooseong Choi Charles Liu Darrin Lee Vasileios Maroulas Vasileios Christopoulos http://arxiv.org/abs/2508.13758v1 Reduction of Electromagnetic Interference in ultra-low noise Bimodal MEG & EEG 2025-08-19T11:57:14Z Single-channel SQUID system technology, operating at a noise level of 100s of aT/$\sqrt{\textrm{Hz}}$, enables the non-invasive detection of synchronized spiking activity at the single-trial level via magnetoencephalography (MEG). However, when combined with simultaneous electroencephalography (EEG) recordings, the noise performance of the ultrasensitive MEG system can be greatly diminished. This issue negates some of the complementary qualities of these two recording methods. In addition, typical electrical components required for electrical stimulation of peripheral nerves, a common method for evoking specific brain responses, are also observed to have a detrimental influence on ultra-low MEG noise performance. These effects are caused by electromagnetic interference (EMI) and typically preclude single-trial detection. This work outlines, how careful design allows a significant reduction of the impact of EMI when these different electronic systems are operated concurrently. This optimization enabled the simultaneous single-trial detection of synchronized spiking activity using these two highly sensitive recording modalities. 2025-08-19T11:57:14Z 4 pages, 4 figures, BMT 2025 conference paper Current Directions in Biomedical Engineering, volume 11, 202-205 (2025) Jim Barnes Lukasz Radzinski Soudabeh Arsalani Gunnar Waterstraat Gabriel Curio Jens Haueisen Rainer Körber 10.1515/cdbme-2025-0152 http://arxiv.org/abs/2508.13689v1 Optimization of continuous-wave NIRS devices for placental monitoring. A simulation study 2025-08-19T09:44:03Z Near infrared spectroscopy (NIRS) is an optical technique that is widely used to monitor tissue oxygenation. These devices take advantage of the near infrared light to monitor deep tissues like brain, muscle or placenta. In this study, we developed a Monte Carlo framework to evaluate the sensitivity of continuous-wave (CW) NIRS devices for monitoring the placenta which a deep layer in the maternal abdomen. This framework can be used to optimize CW-NIRS acquisition parameters (integration time, source detector separation) before going into clinical applications. 2025-08-19T09:44:03Z Charly Caredda Frédéric Lange Uzair Hakim Niccole Ranaei-Zamani Anna L David Dimitrios Siassakos Rosalind Aughwane Sara Hillman Olayinka Kowobari Subhabrata Mitra Ilias Tachtsidis http://arxiv.org/abs/2508.13304v1 Differentiable Forward and Back-Projector for Rigid Motion Estimation in X-ray Imaging 2025-08-18T18:44:08Z Objective: In this work, we propose a framework for differentiable forward and back-projector that enables scalable, accurate, and memory-efficient gradient computation for rigid motion estimation tasks. Methods: Unlike existing approaches that rely on auto-differentiation or that are restricted to specific projector types, our method is based on a general analytical gradient formulation for forward/backprojection in the continuous domain. A key insight is that the gradients of both forward and back-projection can be expressed directly in terms of the forward and back-projection operations themselves, providing a unified gradient computation scheme across different projector types. Leveraging this analytical formulation, we develop a discretized implementation with an acceleration strategy that balances computational speed and memory usage. Results: Simulation studies illustrate the numerical accuracy and computational efficiency of the proposed algorithm. Experiments demonstrates the effectiveness of this approach for multiple X-ray imaging tasks we conducted. In 2D/3D registration, the proposed method achieves ~8x speedup over an existing differentiable forward projector while maintaining comparable accuracy. In motion-compensated analytical reconstruction and cone-beam CT geometry calibration, the proposed method enhances image sharpness and structural fidelity on real phantom data while showing significant efficiency advantages over existing gradient-free and gradient-based solutions. Conclusion: The proposed differentiable projectors enable effective and efficient gradient-based solutions for X-ray imaging tasks requiring rigid motion estimation. 2025-08-18T18:44:08Z Xiao Jiang Xin Wang Ali Uneri Wojciech B. Zbijewski J. Webster Stayman 10.1109/TBME.2025.3643742