https://arxiv.org/api/qpjnsqZQgwbSy0kMc49hJiWg3N4 2026-09-11T00:26:41Z 9200 105 15 http://arxiv.org/abs/2608.10170v1 Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction 2026-08-10T19:37:31Z Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration. 2026-08-10T19:37:31Z Mojtaba Safari Shansong Wang Zach Eidex Matthew Goette Tonghe Wang Zhen Tian Xiaofeng Yang 10.1109/TMI.2026.3724112 http://arxiv.org/abs/2608.09616v1 Lost in k-Space: An Open-Source MR-Physics Escape Room 2026-08-10T13:55:49Z Introduction. Operating an MR scanner for technical and clinical research requires multidisciplinary competencies beyond MR physics, including safety management and teamwork. Gamification, particularly educational escape rooms, have been associated with improved motivation, engagement and knowledge retention in health professional education. Materials and Methods. We developed an MR-physics-themed educational escape room for the 41st Annual Meeting of the ESMRMB. Designed for teams of four with a time limit of 25 minutes, the room reproduced the atmosphere of an MR control room. The five puzzles covered the Larmor equation, sequence composition, MR safety and acoustical identification of MR sequences. Custom ESP32 electronics allowed the puzzles to communicate in real time with each other and with the game master Results. The room ran without technical interruptions and was played by 39 teams (approximately 160 participants); 12 solved it (escape rate 31%), with a median solution time of 21 minutes and 53 seconds. Early-career researchers acted as game masters. Discussion. The escape rate aligns with comparable activities targeting scientific audiences. Difficulty can be tuned by adjusting puzzle obscurity, component availability, required prior knowledge and mental leaps. A modified version could usefully supplement mandatory MR safety training. Code, schematics, machining files and documentation are released as open source. 2026-08-10T13:55:49Z 15 pages, 3 figures Sabine Melanie Räuber Marta Brigid Maggioni Francesco Santini http://arxiv.org/abs/2608.09323v1 Openable Force-Balanced Halbach Magnets: From Fibonacci Sphere Simulations to Icosahedral Realizations 2026-08-10T09:04:47Z A long-standing goal in magnet design is to completely surround a volume of highly homogeneous magnetic field with permanent magnets while maintaining practical access to that volume. In this work, we present a theoretical and experimental investigation of mechanically accessible spherical magnets in Halbach configuration that can be opened with minimal or vanishing force. Focusing on dipolar Halbach spheres composed of discrete magnetic subunits, we derive conditions for force-free opening along specific cutting planes. These conditions define a continuous set of geometries for which tensile magnetic forces cancel, leaving only shear components, enabling mechanically effortless opening. The theoretical predictions are validated experimentally using icosahedral approximations of the Halbach sphere, for which both opening forces and magnetic field properties are measured. The results demonstrate that excellent field homogeneity can be preserved while reducing opening forces by orders of magnitude. Although discussed in detail for the dipolar case, the theoretical framework is general and applicable to higher-order multipole Halbach systems. Finally, the concepts are extended to spherocylindrical Halbach configurations, highlighting their potential for large-volume, highly homogeneous, and mechanically accessible permanent-magnet systems for magnetic resonance 2026-08-10T09:04:47Z 12 pages, 10 figures, prepared for a special issue on low field magnetic resonance in J. Magn. Reson Ingo Rehberg Helmut Soltner Peter Blümler http://arxiv.org/abs/2605.14987v3 A Monte Carlo positronium decay source model with multiple annihilation channels in GATE 2026-08-09T22:39:12Z Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the definition of an arbitrary number of decay channels characterised by lifetime, branching fraction, annihilation multiplicity (2g/3g), and optional prompt photon emission. The model is validated through analytical and numerical benchmarks, including lifetime distributions, branching fraction consistency, photon kinematics, and prompt photon emission. Its practical applicability is demonstrated using simulations of mixed annihilation scenarios and the NEMA IEC phantom with a large field-of-view PET system. The proposed model accurately reproduces input lifetime distributions as weighted sums of exponential components and correctly samples decay channel fractions. Simulated two- and three-photon annihilation kinematics are consistent with theoretical expectations. Complex mixtures of decay channels, including varying 3g-to-2g ratios and multi-component ortho-positronium lifetimes, are correctly modelled, with observable signatures reflected in both temporal and energy distributions. Phantom simulations demonstrate the capability to generate realistic positronium-sensitive datasets. This work provides the first general-purpose, multi-channel positronium decay model integrated into GATE, enabling realistic simulations of positronium behaviour in complex media. The model supports the development and optimisation of positronium-based imaging techniques, including PLI and multi-photon PET, and applies to medical imaging, industrial tomography, and fundamental physics studies. Its public availability and compatibility with standard GATE workflows make it a valuable tool for the broader research community. 2026-05-14T15:49:19Z secoond update: a few clarifications added, appendix with explicit calculation examples for realistic materials added, 26 pages, 12 figures Wojciech Krzemien Mateusz Bala Kamil Dulski Wojciech Zdeb Aurélien Coussat Beatrix C. Hiesmayr Konrad Klimaszewski Michał Obara Lech Raczyński Roman Y. Shopa http://arxiv.org/abs/2608.08919v1 Toward CT-Equivalent Image Quality in Low-Dose Radiotherapy Planning: Conditional Diffusion-Based CBCT-to-CT Synthesis and the Impact of CBCT Input Representation 2026-08-09T21:15:08Z During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose. To mitigate this, low-dose cone-beam CT (CBCT) is routinely acquired during treatment delivery. However, CBCT image quality remains insufficient for accurate dose calculation and adaptive radiotherapy planning due to increased scatter, noise, beam hardening, and reconstruction related artifacts. This study develops a supervised deep learning based CBCT to CT synthesis framework using a conditional denoising diffusion probabilistic model (DDPM), where the generation of a CT-based planning for accurate positioning and dose calculation is obtained using generative models with low dose CBCT imaging. Beyond demonstrating CBCT to CT synthesis, the primary objective is to investigate how the representation of CBCT input data, either standard clinical DICOM CBCT images or filtered back-projection (FDK) reconstructions from raw projection data, affects the performance of diffusion based CT synthesis. The overarching aim is to assess whether physics aware CBCT representations better support CT-equivalent image quality while maintaining reduced imaging dose in radiotherapy workflows. 2026-08-09T21:15:08Z 9 pages, 6 figures, European Conference of Radiology (ECR) 2026 Alzahra Altalib Chunhui Li Christopher Hamill Taylor Sankar Pillai Alessandro Perelli 10.26044/ecr2026/C-28213 http://arxiv.org/abs/2608.08819v1 MRI super-resolution in ten sampling steps using a diffusion bridge model 2026-08-09T17:09:21Z Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions. 2026-08-09T17:09:21Z Mojtaba Safari Hang Yu Zach Eidex Mingzhe Hu Ryan J. Sanford Alexandru Florea Shansong Wang Chih-Wei Chang Erik H Middlebrooks Aditya Juloori Stanley L. Liauw Ralph Weichselbaum Xiaofeng Yang http://arxiv.org/abs/2608.07687v1 Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction 2026-08-07T18:20:56Z Obtaining consistent quantitative maps of myelin content and relaxation times across different sites and vendors is essential for advancing our understanding of brain development. Herein, we present a harmonized, vendor-agnostic magnetic resonance acquisition method designed for joint T1, T2, and myelin water fraction mapping, along with a method for rapid B1+ and B1- field estimation. We used our dictionary-based fitting and multi-compartment modeling for joint mapping of T1, T2 and myelin water fraction. Self-navigation-based retrospective motion correction was integrated with subspace reconstruction to track and correct rigid head motion during scanning, operating without the need for external hardware. Simulations, phantom and in vivo experiments confirmed the sensitivity and accuracy of the method, particularly for short T2 values corresponding to myelin, and demonstrated consistent performance across multiple scanner types. Coupled with the harmonized calibration scan, the proposed package offers a practical tool for multi-site, multi-vendor neuroimaging studies in both adult and pediatric populations. 2026-08-07T18:20:56Z 49 pages, 8 figures, supplementary material included. Submitted to Imaging Neuroscience Unay Dorken Gallastegi Shohei Fujita Yohan Jun Antoine Delattre-Klauser Gian Franco Piredda Tom Hilbert Cemre Ariyurek Eugene Milshteyn Shizhuo Li Yuting Chen Xingwang Yong Kwok-Shing Chan Qiang Liu Seonghwan Yee Yogesh Rathi Maxim Zaitsev Jon-Fredrik Nielsen Onur Afacan Camilo Jaimes Patricia Ellen Grant Borjan Gagoski Berkin Bilgic http://arxiv.org/abs/2608.07389v1 An Angular Spectrum Method for Nonlinear Propagation in Heterogeneous Tissue with Immersed Sources for Ultrasound 2026-08-07T16:36:34Z A modified angular spectrum method (ASM) is developed for three-dimensional nonlinear acoustic propagation through heterogeneous tissue, targeting transcranial and therapeutic ultrasound. First, a consistent obliquity correction is applied to both the linear and nonlinear operators of the split-step update. The attenuation and dispersion filter carries a per-mode k/kz factor on the full wavenumber-frequency grid, so each component accumulates absorption and phase over its true path length dz/cos(theta), while the Burgers coefficient is scaled by the power-weighted mean beam obliquity. Second, the retarded-time Burgers update is discretized with a second-order Kurganov-Tadmor central-upwind flux using MUSCL reconstruction and SSP-RK2 time integration, composed with diffraction and attenuation through Strang splitting with adaptive CFL sub-cycling, resolving fully developed shocks without the temporal refinement that the CFL coupling imposes on FDTD. Third, a plane-by-plane source-injection scheme decomposes deeply curved bowl transducers into axial slices injected at their correct propagation depths, preserving the aperture-dependent shock-formation distance. Phase-and-amplitude screens derived from skull CT data model transcranial aberration and insertion loss, and three enhanced absorbing-boundary treatments reduce boundary reflections by a factor of 2.4. Analytical validation reproduces the baffled-piston far-field pattern to 0.014 RMS and the focused-piston focal pressure to within 2.3 percent. In a transcranial benchmark through an ex vivo human skull, the ASM matches the Fullwave 2 focal-plane intensity to 1.1 percent RMS and predicts a 5.4 dB through-skull insertion loss. For a bowl transducer (R = 80 mm, f0 = 1 MHz), the ASM matches the Fullwave 2 focal depth to within 2.3 percent with 9x less memory and 2.9x less wall time. 2026-08-07T16:36:34Z Gianmarco Pinton http://arxiv.org/abs/2608.07368v1 Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings 2026-08-07T16:11:11Z Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement. Zero echo time (ZTE) MRI visualizes cortical bone and yields FAI angles that agree with CT, but automated angle extraction remains limited. We developed and validated automated FAI angle computation from ZTE MRI and assessed agreement with expert manual measurements in a cross-sectional study (level of evidence, 3). Pelvic ZTE MRI was acquired in 73 participants (mean age 36.8 +/- 18.5 years; 51 women, 22 men), yielding 135 hips. nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks. Custom geometric algorithms computed alpha, femoral neck-shaft, Tonnis, coronal and sagittal center-edge, and acetabular version angles from inferred segmentations. Measurements on 35 test hips were compared with the mean of two radiologists' manual measures using intraclass correlation (ICC) and Bland-Altman analysis. Dice exceeded 0.96 for bone and ranged from 0.65 to 0.83 for landmarks. Median landmark error was 0.38 mm (femoral head), 0.82 mm (lateral acetabulum), and <2.5 mm (medial acetabulum, greater trochanter). Interrater ICC was excellent for acetabular version, coronal center-edge, and Tonnis (>=0.82) but poor for alpha and femoral neck-shaft. Model versus rater-mean agreement was excellent for acetabular version, coronal center-edge, and Tonnis (0.92-0.96), good for mid-acetabular sagittal center-edge (0.74), and fair for alpha (0.45) and femoral neck-shaft (0.55). Model Bland-Altman limits of agreement were narrower than interrater limits for most angles. Fully automated morphometric assessment from ZTE MRI is feasible and performs comparably to expert readers for most coverage and version angles. 2026-08-07T16:11:11Z Jack Consolini Eric A. Bogner Meghan Sahr Matthew F. Koff Kevin M. Koch Hollis G. Potter http://arxiv.org/abs/2608.07155v1 Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging 2026-08-07T12:21:17Z Inter-crystal scatter (ICS) events pose a significant challenge in ultrahigh- resolution positron emission tomography (UHR-PET), especially as detector crystals become smaller and their readouts increasingly segmented. Current approaches either reject these events, reducing sensitivity, or accept them with suboptimal positioning algorithms, degrading image resolution. We present a feed forward neural network to optimize ICS event recovery by inferring the line-of-response belonging to the first Compton interaction. Our approach was validated using both Monte Carlo simulations and experimental data from the fully pixelated LabPET-IIbased preclinical and brain UHR-PET scanners.Results demonstrate a 70% to 106% increase in sensitivity while preserving sub-millimeter spatial resolvability (down to 1.6 mm) compared to conventional methods. This ICS recovery approach is an effective solution that compensates for the lower detection efficiency of small, pixelated detectors in UHR-PET, enabling reduced scan times and lower radiation doses while largely preserving image quality. 2026-08-07T12:21:17Z 19 pages, to b published in Physic in Medecine and Biology Alexandre Bernier Roger Lecomte Jean-Baptiste Michaud http://arxiv.org/abs/2608.06853v1 Lens-Aware Differentiable Beamforming for In Vivo Distributed Aberration Correction with Curvilinear Transducers 2026-08-07T06:23:02Z This work extends ultrasound autofocusing via common midpoint phase error optimization to support curvilinear array geometries. Iterative model-based aberration correction via local sound speed estimation is performed by accounting for refraction caused by the transducer lens by using a differentiable bent-ray tracing approach. Model validation is performed in silico, using calibrated sound speed phantoms, and on in vivo human liver images. This work represents the first large-scale in vivo validation of our distributed aberration-correction method on 321 acquisitions from 81 high-BMI human liver subjects. In acquired images with anechoic regions, average contrast and CNR improved by $1.42 \pm 1.63$ dB (+18.4%), and $0.09 \pm 0.14$ (+10.3%), respectively. An average improvement was also observed across multiple image quality metrics: speckle brightness (+20.1%), coherence factor (+13.1%), lag-one coherence (+2.6%), common-midpoint correlation coefficient (+0.7%), and common-midpoint phase error (-9.1%, lower is better). All metric improvements were statistically significant. Additionally, a significant qualitative improvement in target structure and visibility was observed. These results demonstrate the potential for future clinical distributed aberration correction techniques using ultrasound autofocusing. 2026-08-07T06:23:02Z Benjamin N. Frey Robin van Velzen Hoda S. Hashemi Samuel Beuret Martin Schneider Alice C. Fan Christian R. Hoerner Sergio J. Sanabria Jeremy J. Dahl http://arxiv.org/abs/2608.06746v1 108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations 2026-08-07T03:14:17Z Objective. Existing commercial time-of-flight positron emission tomography (TOF-PET) systems yield a coincidence time resolution (CTR) of ~200 ps or less full width at half maximum (FWHM). Recently, there has been a challenge to achieve a CTR of 100 ps FWHM at the system level. However, current silicon photomultipliers (SiPMs) and 20-mm-thick scintillators in conventional single-ended readout scheme is difficult to achieve 100 ps CTR; the photon transport time spread (PTS) within the scintillator crystal is a major barrier. Differences in the interaction position result in variations in PTS on the order of several tens of ps, thereby degrading the CTR. A shorter scintillator can improve CTR; however, this can degrade detection efficiency. Approach. To overcome this trade-off between the CTR and detection efficiency, we previously proposed xDetector, an orthogonally stacked configuration along the longitudinal axis of scintillator crystals. We investigated the CTR potential of the xDetector by improving the scintillator, photodetector, and readout electronics, and by applying CTR correction based on a three-dimensional interaction within the scintillator. Main results. Based on error propagation, the CTR of the paired xDetector was calculated as 113.5 $\pm$ 2.7 ps FWHM. Furthermore, the CTR of the xDetector was measured at four positions along the longitudinal axis by manually sliding the xDetector, and the corrected achieved CTR was 108.6 $\pm$ 1.9 ps FWHM. Moreover, compared with the conventional single detector using a 20.0 mm scintillator, CTR improved by an average of 10.3%. Significance. The xDetector offers potential as a PET detector concept to achieve a CTR of 100 ps FWHM. Such timing performance is expected to improve TOF-PET image quality and quantitative accuracy, contributing to more reliable disease detection and diagnosis than current PET detectors. 2026-08-07T03:14:17Z Arisa Sanzen Yuya Onishi Takahiro Moriya Tomohide Omura Ryosuke Ota http://arxiv.org/abs/2608.06321v1 An open-source framework for predicting ultrasound neuromodulation: bridging tissue elastomechanics and neuron firing dynamics 2026-08-06T17:36:20Z Transcranial focused ultrasound is a non-invasive neuromodulation modality with millimetre-scale resolution, but its biophysical mechanism of action remains unresolved. Exposure is conventionally specified by transducer surface or derated focal pressure, quantities only indirectly related to what matters for therapy: which neurons fire and through which pathway. We address this gap with an end-to-end computational framework that maps a transcranial acoustic field to per-voxel neural firing maps registered to anatomy. The pipeline couples heterogeneous nonlinear full-wave acoustic propagation, viscoelastic shear-wave propagation, Pennes bioheat diffusion, a bilayer-mechanics conversion from tissue strain to membrane tension, and a multi-compartment Hodgkin-Huxley neuron carrying mechanosensitive, cavitation-coupled, calcium-coupled, thermosensitive, astrocytic-gliotransmitter, and mechanosensitive-synaptic pathways. Six candidate mechanisms are implemented as interchangeable components on a shared neuron model, so their firing predictions can be compared directly on the same field, and every numerical parameter is classified by source and bracketed by sensitivity analysis. We demonstrate the framework on a theta-burst sonication delivered through a micro-CT human-skull specimen targeting the left dorsal anterior cingulate cortex, predicting a focal firing zone of approximately 8,500 mm^3 at a focal thermal rise well within ITRUSST consensus safety envelopes. The principal output is a per-voxel firing-volume map resolved jointly with the acoustic, elastic, and thermal field histories that drive it, giving spatially resolved, falsifiable predictions that are testable against high-density extracellular recordings and support parameter estimation, cell-type-resolved mechanism identification, and quantitative safety assessment for ultrasound neuromodulation. 2026-08-06T17:36:20Z Gianmarco Pinton http://arxiv.org/abs/2608.06158v1 Evaluation of Silicon-Based Photon-Counting CT for Coronary Stenosis Quantification with Realistic Coronary Artery Phantoms 2026-08-06T15:27:31Z Objective: To quantify the impact of high-resolution deep silicon photon-counting CT (dSi-PCCT) on coronary stenosis quantification in anatomically realistic calcified coronary artery phantoms using Micro-CT as ground truth. Methods: Twelve vessel sections representing four calcification geometries (Type I-IV) and three luminal iodine concentrations (10, 15, and 20 mg/mL) were scanned under static conditions using energy-integrating detector CT (EID-CT), dSi-PCCT, and Micro-CT. Images were registered to Micro-CT and segmented using an automated threshold-based pipeline. The primary analysis compared longitudinal profiles of Micro-CT-referenced percent area stenosis and segmented vessel area. A secondary analysis evaluated ellipse-derived percent area stenosis and percent vessel-area deviation at the maximum-calcification cross-section. Results: dSi-PCCT reduced whole-profile mean absolute error in Micro-CT-referenced percent area stenosis from 3.10% with EID-CT to 1.62% (p=0.027) and reduced segmented vessel-area error from 0.55 to 0.31 mm2 (p=0.001). In the secondary analysis, absolute deviations in ellipse-derived percent area stenosis ranged from 0.1% to 6.5% for dSi-PCCT and from 0.8% to 24.2% for EID-CT (p<0.001). Mean absolute differences in percent vessel-area deviation from Micro-CT were also lower with dSi-PCCT than with EID-CT (15.0% vs 26.6%, p<0.001). Conclusion: Under static, resolution-optimized conditions, dSi-PCCT improved task-based coronary stenosis quantification and vessel delineation relative to EID-CT, supporting further evaluation in dynamic phantoms and clinical CCTA. 2026-08-06T15:27:31Z Maria Jose Medrano Jed Pack Stephen Araujo Grant M. Stevens Koen Nieman Ge Wang Bruno De Man Adam S. Wang http://arxiv.org/abs/2608.05824v1 A Unified Analytical Framework for LYSO-SiPM Scintillation Pulse Dynamics 2026-08-06T09:54:09Z Existing scintillation-detector models typically treat scintillation kinetics, optical transport, silicon photomultiplier (SiPM) response, and timing statistics separately, limiting end-to-end prediction of waveform formation and detector performance. We present a unified analytical framework for lutetium-yttrium oxyorthosilicate (LYSO)-SiPM scintillation detectors that links these processes within a single forward model. The framework incorporates finite thermalization, depth-dependent optical transit-time spread, and microcell occupancy dynamics to provide a physics-based description of macroscopic pulse formation. It yields closed-form exponentially modified Gaussian pulses in the linear regime, state-dependent integral solutions in saturation, and recovers the conventional bi-exponential pulse model---ubiquitously used yet hitherto only empirically justified in scintillation pulse fitting and sparse-sampling reconstruction---as a controlled reduction of the full optoelectronic cascade. Experimental validation on 10,000 directly digitized Na-22 pulses shows that the dynamic saturation model captures amplitude-dependent waveform distortion and is favored by the Akaike information criterion (AIC) over a matched bi-exponential baseline in 100/100 high-amplitude pulses and 98/100 medium-amplitude pulses. By coupling the dynamic triggering rate to compound Poisson statistics, the framework also predicts current-variance envelopes and Fisher-information-based timing limits, including an intrinsic coincidence timing resolution lower bound of about 100 ps full width at half maximum (FWHM) for a reference 511-keV LYSO-SiPM configuration. These results deepen the physical understanding of scintillation-detector waveform formation and timing limits by clarifying how scintillation kinetics, optical transport, and SiPM microcell dynamics jointly shape the observed response. 2026-08-06T09:54:09Z Ao Qiu Qingguo Xie