https://arxiv.org/api/xj4JZYllUcm5u3czVDovVOT2iaE2026-06-26T08:40:08Z9008103515http://arxiv.org/abs/2507.16065v3Handcrafted vs. Deep Radiomics vs. Fusion vs. Deep Learning: A Comprehensive Review of Machine Learning -Based Cancer Outcome Prediction in PET and SPECT Imaging2025-08-25T18:20:29ZMachine learning (ML), including deep learning (DL) and radiomics-based methods, is increasingly used for cancer outcome prediction with PET and SPECT imaging. However, the comparative performance of handcrafted radiomics features (HRF), deep radiomics features (DRF), DL models, and hybrid fusion approaches remains inconsistent across clinical applications. This systematic review analyzed 226 studies published from 2020 to 2025 that applied ML to PET or SPECT imaging for outcome prediction. Each study was evaluated using a 59-item framework covering dataset construction, feature extraction, validation methods, interpretability, and risk of bias. We extracted key details including model type, cancer site, imaging modality, and performance metrics such as accuracy and area under the curve (AUC). PET-based studies (95%) generally outperformed those using SPECT, likely due to higher spatial resolution and sensitivity. DRF models achieved the highest mean accuracy (0.862), while fusion models yielded the highest AUC (0.861). ANOVA confirmed significant differences in performance (accuracy: p=0.0006, AUC: p=0.0027). Common limitations included inadequate handling of class imbalance (59%), missing data (29%), and low population diversity (19%). Only 48% of studies adhered to IBSI standards. These findings highlight the need for standardized pipelines, improved data quality, and explainable AI to support clinical integration.2025-07-21T21:03:12ZMohammad R. SalmanpourSomayeh Sadat MehrniaSajad Jabarzadeh GhandiluSonya FalahatiShahram TaebGhazal MousaviMehdi MaghsoudiAhmad ShariftabriziIlker HacihalilogluArman Rahmimhttp://arxiv.org/abs/2508.17961v1Beam Geometry and Input Dimensionality: Impact on Sparse-Sampling Artifact Correction for Clinical CT with U-Nets2025-08-25T12:21:49ZThis study aims to investigate the effect of various beam geometries and dimensions of input data on the sparse-sampling streak artifact correction task with U-Nets for clinical CT scans as a means of incorporating the volumetric context into artifact reduction tasks to improve model performance. A total of 22 subjects were retrospectively selected (01.2016-12.2018) from the Technical University of Munich's research hospital, TUM Klinikum rechts der Isar. Sparsely-sampled CT volumes were simulated with the Astra toolbox for parallel, fan, and cone beam geometries. 2048 views were taken as full-view scans. 2D and 3D U-Nets were trained and validated on 14, and tested on 8 subjects, respectively. For the dimensionality study, in addition to the 512x512 2D CT images, the CT scans were further pre-processed to generate a so-called '2.5D', and 3D data: Each CT volume was divided into 64x64x64 voxel blocks. The 3D data refers to individual 64-voxel blocks. An axial, coronal, and sagittal cut through the center of each block resulted in three 64x64 2D patches that were rearranged as a single 64x64x3 image, proposed as 2.5D data. Model performance was assessed with the mean squared error (MSE) and structural similarity index measure (SSIM). For all geometries, the 2D U-Net trained on axial 2D slices results in the best MSE and SSIM values, outperforming the 2.5D and 3D input data dimensions.2025-08-25T12:21:49ZTina DorostiJohannes ThalhammerSebastian PeterhanslDaniela PfeifferFranz PfeifferFlorian Schaffhttp://arxiv.org/abs/2501.01173v3High-Resolution Imaging of Plant Delayed Luminescence2025-08-25T06:51:38ZDelayed luminescence (DL) is a quantized signal that is characteristic of photoexcited molecules entering a relaxed state. Studying DL provides critical insight into photophysical mechanisms through the analysis of specific spatiotemporal dynamics. In this study, we developed a high-sensitivity DL imaging system using a quantitative scientific complementary metal-oxide-semiconductor (qCMOS) camera and a single-photon counting resolution. By optimizing the optical architecture and signal processing algorithms together, we achieved full-field spatiotemporal DL imaging at megapixel resolution (i.e., $2304 \times 4096$ pixels). Key findings include the following: (1) we observed spatial heterogeneity in DL intensity across the leaves of Arabidopsis thaliana, with stronger signals detected in veins and at sites of mechanical injury; (2) species-specific DL responses occur in response to oxidative stress, with Hydrocotyle vulgaris and Ginkgo biloba showing enhanced central DL activity; (3) excitation using white light induced maximum DL intensity, while red and blue light differentially modulated decay kinetics. Finally, we develop a two-level quantum model that links DL dynamics to the populations of excited-state electrons, thereby developing a theoretical framework for future photophysical research. Collectively, this work establishes a theoretical and technological framework for advancing plant phenotyping under stress conditions and optimizing light environments.2025-01-02T09:54:47Z6 figuresYan-Xia LiuHai-Yu FanYu-Hao WangYan-Liang WangSheng-Wen LiShi-Jian LiXu-Ri YaoQing Zhao10.1016/j.jphotobiol.2025.113231http://arxiv.org/abs/2310.06191v2Investigating the Correlation between Force Output, Strains, and Pressure for Active Skeletal Muscle Contractions2025-08-25T01:04:11ZMeasuring the forces of individual muscles in a muscle group around a joint is non-trivial, and researchers have suggested using surrogates for individual muscle forces instead. Traditionally, experimentalists have shown that the force output of the skeletal muscle tissue can be correlated to the intra-muscular pressure (IMP) generated by the muscle belly. However, IMP proves difficult to measure in vivo, due to variations from sensor placement and invasiveness of the procedure. Numerical biomechanical simulations offer a tool to analyze muscle contractions, enabling new insights into the correlations among non-invasive experimentally measurable quantities such as strains, and the force output. In this work, we investigate the correlations between the muscle force output, the principal, shear and volumetric strains experienced by the muscle, as well as the pressure developed within the muscle belly as the tissue undergoes isometric contractions with varying activation profiles and magnitudes. It is observed that pressure does not correlate well with force output under higher sub-maximal and maximal activation levels, especially at locations away from the center of the muscle belly due to pressure relaxation effects. This study reveals strong correlations between force output and the strains at all locations of the belly, irrespective of the type of activation considered. This observation offers evidence for further in vivo studies using experimentally measurable principal and volumetric strains in the muscle belly as proxies for the force generation by the individual muscle and consequently enables the estimation on the contribution of various muscle groups to the total force.2023-10-09T22:42:58ZKaran TanejaXiaolong HeChung-Hao LeeJohn HodgsonUsha SinhaShantanu SinhaJ. S. Chenhttp://arxiv.org/abs/2508.07103v2Acoustic Holography in the Megahertz Frequency Range with Optimal Lens Topologies and Nonlinear Acoustic Feedback2025-08-24T14:33:56ZAcoustic holography in the megahertz frequency range can impact numerous applications, including manufacturing, non-destructive testing, and transcranial ultrasound. However, designing lens topologies for complex acoustic holograms in the megahertz range poses a significant challenge, as weave propagation effects through the lens cannot be ignored. Here, we show that the inherent ability of heterogeneous angular spectrum approach to incorporate in plane varying speed-of-sound maps and support rapid differentiable optimization of lens thickness profiles can generate lens topologies for high fidelity acoustic holography. Crucially, we show that this framework can also account for wavefront aberrations in the propagation media, providing the opportunity to reconfigure this disruptive technology for high precision neuro-interventions. Our investigations also revealed that low frequency acoustic feedback generated by nonlinear mixing of high frequency waves allows attaining accurate skull-compensating lens alignment and creates the possibility to monitor CSF fluid build-up and removal in hydrocephalus. Together, our findings support the design of simple, economical, and high-performance ultrasound systems.2025-08-09T21:13:37ZPradosh Pritam DashCostas D. Arvanitishttp://arxiv.org/abs/2508.16475v1Transcranial Photoacoustic Imaging for Human Intracranial Pressure Evaluation2025-08-22T15:42:26ZPhotoacoustic imaging (PAI), by combining high optical contrast with ultrasonic resolution, offers a promising noninvasive approach for dynamic monitoring of cerebral vasculature. However, transcranial PAI still faces significant challenges due to strong attenuation of both optical and acoustic signals by the skull. In this study, we propose a multi-wavelength photoacoustic tomography system and method for intracranial pressure (ICP) assessment, enabling visualization of cross-sectional structures of the middle cerebral artery (MCA) through the human temporal bone. By utilizing multi-wavelength excitation in the near-infrared-I (NIR-I) window, quantitative maps of blood oxygen saturation ($\mathbf{sO_2}$) are reconstructed, and the relationship between oxygenation dynamics and ICP variations is established. Experimental results demonstrate that the proposed system can successfully capture dynamic $\mathbf{sO_2}$ fluctuations in the MCA despite skull attenuation, revealing its characteristic responses to ICP changes. This work provides a high-precision, noninvasive imaging tool for early stroke diagnosis, cerebral vascular function assessment, and neurointerventional guidance, highlighting the clinical translational potential of PAI in neuroscience.2025-08-22T15:42:26ZCo-first authors: Ruixi Sun, Hengrong Lan, Yuanyuan Dang. Corresponding authors: Zhongqi Li (jasonlee0091@outlook.com), Hulin Zhao (zhaohulin_90@sohu.com), Fei Gao (fgao@ustc.edu.cn)Ruixi SunHengrong LanYuanyuan DangYunhui JiangYoushen XiaoSheng LiaoFan ZhangDaohuai JiangZhongqi LiHulin ZhaoFei Gaohttp://arxiv.org/abs/2508.16209v1Deep learning-enabled virtual multiplexed immunostaining of label-free tissue for vascular invasion assessment2025-08-22T08:31:03ZImmunohistochemistry (IHC) has transformed clinical pathology by enabling the visualization of specific proteins within tissue sections. However, traditional IHC requires one tissue section per stain, exhibits section-to-section variability, and incurs high costs and laborious staining procedures. While multiplexed IHC (mIHC) techniques enable simultaneous staining with multiple antibodies on a single slide, they are more tedious to perform and are currently unavailable in routine pathology laboratories. Here, we present a deep learning-based virtual multiplexed immunostaining framework to simultaneously generate ERG and PanCK, in addition to H&E virtual staining, enabling accurate localization and interpretation of vascular invasion in thyroid cancers. This virtual mIHC technique is based on the autofluorescence microscopy images of label-free tissue sections, and its output images closely match the histochemical staining counterparts (ERG, PanCK and H&E) of the same tissue sections. Blind evaluation by board-certified pathologists demonstrated that virtual mIHC staining achieved high concordance with the histochemical staining results, accurately highlighting epithelial cells and endothelial cells. Virtual mIHC conducted on the same tissue section also allowed the identification and localization of small vessel invasion. This multiplexed virtual IHC approach can significantly improve diagnostic accuracy and efficiency in the histopathological evaluation of vascular invasion, potentially eliminating the need for traditional staining protocols and mitigating issues related to tissue loss and heterogeneity.2025-08-22T08:31:03Z29 Pages, 7 FiguresBME Frontiers, AAAS (2026)Yijie ZhangCagatay IsilXilin YangYuzhu LiAnna EliaKarin AtlanWilliam Dean WallaceNir PillarAydogan Ozcan10.34133/bmef.0226http://arxiv.org/abs/2508.15739v1Pseudo-spectral model of elastic-wave propagation through toothed-whale head anatomy, and implications for biosonar2025-08-21T17:30:11ZThe sound-localization and, in particular, biosonar system of toothed whales is exceptionally performant. How this is achieved is not clear, given that: (i) toothed whales have no pinnae; (ii) while their auditory pathways have been studied in detail, no specific feature apparently replacing the pinna has been identified. In this study, we employ a pseudo-spectral time domain (PSTD) numerical scheme to model three-dimensional elastic wave propagation through a toothed-whale head including soft tissues. Computed tomography (CT) scans were utilized to build a three-dimensional velocity-density model of the specimen's head, parametrized on a high-resolution $1.11$ mm voxel grid. We first validate our wave propagation solver, identifying a range of frequencies and spatial scale lengths where the PSTD scheme captures the complexities of elastic wave propagation through toothed-whale anatomy. We next focus on the toothed whale's ability to locate sources on the median plane, where the role of anatomy is crucial. A 45 kHz central frequency burst (dolphin-like click) was modeled and directed at elevation angles from $-90^\circ$ to $+90^\circ$ in $5^\circ$ steps along the midsagittal plane. We find that the incoming sound can be localized, via correlation, from the reverberated portion of the time-domain waveforms recorded at the tympano-periotic complex locations.2025-08-21T17:30:11ZFawad AliCarlos García A.Aida Hejazi-NooghabiLapo Boschi10.1121/10.0041770http://arxiv.org/abs/2504.19326v2Thermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation2025-08-21T11:05:34ZTo navigate medical instruments safely and accurately inside a patient's vascular tree, combining X-ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks, necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non-fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without x-ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micro-machining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter's mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.2025-04-27T18:52:01Z23 pages, 8 figuresAlex RanneHeiko MaierJinshi ZhaoSongli MoeyAyhan AktasManik ChanaBurak TemelkuranNassir NavabFerdinando Rodriguez Y Baenahttp://arxiv.org/abs/2412.05063v3Kinetic-Diffusion-Rotation Algorithm for Dose Estimation in Electron Beam Therapy2025-08-21T09:28:56ZMonte Carlo methods are state-of-the-art when it comes to dosimetric computations in radiotherapy. However, the execution time of these methods suffers in high-collisional regimes. We address this problem by introducing a kinetic-diffusion particle tracing scheme. This algorithm, first proposed in the context of neutral transport in fusion energy, relies on explicit simulation of the kinetic motion in low-collisional regimes and dynamically switches to motion based on a random walk in high-collisional regimes. The random walk motion maintains the first two moments (mean and variance) of the kinetic motion. We derive an analytic formula for the mean kinetic motion and discuss the addition of a multiple scattering distribution to the algorithm. In contrast to neutral transport, the radiation transfer setting does not readily admit to an analytical expression for the variance of the kinetic motion, and we therefore resort to the use of a lookup table. We test the algorithm for dosimetric computations in radiation therapy on a 2D CT scan of a lung patient. Using a simple particle model, our Python implementation of the algorithm is nearly 33 times faster than an equivalent kinetic simulation at the cost of a small modeling error.2024-12-06T14:19:42ZKlaas WillemsVince MaesZhirui TangGiovanni Samaeyhttp://arxiv.org/abs/2508.15873v1Active Prostate Phantom with Multiple Chambers2025-08-21T08:51:34ZProstate cancer is a major global health concern, requiring advancements in robotic surgery and diagnostics to improve patient outcomes. A phantom is a specially designed object that simulates human tissues or organs. It can be used for calibrating and testing a medical process, as well as for training and research purposes. Existing prostate phantoms fail to simulate dynamic scenarios. This paper presents a pneumatically actuated prostate phantom with multiple independently controlled chambers, allowing for precise volumetric adjustments to replicate asymmetric and symmetric benign prostatic hyperplasia (BPH). The phantom is designed based on shape analysis of magnetic resonance imaging (MRI) datasets, modeled with finite element method (FEM), and validated through 3D reconstruction. The simulation results showed strong agreement with physical measurements, achieving average errors of 3.47% in forward modeling and 1.41% in inverse modeling. These results demonstrate the phantom's potential as a platform for validating robotic-assisted systems and for further development toward realistic simulation-based medical training.2025-08-21T08:51:34ZIROS 2025, Oct 2025, Hangzhou (Chine), ChinaSizhe TianCRIStAL, DEFROSTYinoussa AdagolodjoCRIStAL, Polytech Lille, DEFROSTJeremie DequidtCRIStAL, DEFROSThttp://arxiv.org/abs/2508.15328v1Technical Note: Low-Dose Simulation for Grating-Based X-Ray Dark-Field Radiography Using a Virtually Decreased Irradiation Area2025-08-21T07:42:38ZBackground: X-ray dark-field radiography uses small-angle scattering to visualize the structural integrity of lung alveoli. To study the influence of dose reduction on clinical dark-field radiographs, one can simulate low-dose images by virtually reducing the irradiated area. However, these simulations can exhibit stripe artifacts. Purpose: Validation of the low-dose simulation algorithm reported by Schick & Bast et al., PLoS ONE, 2024. Furthermore, we want to demonstrate that stripe artifacts observed in simulated images at very low-dose levels are introduced by limitations of the algorithm and would not appear in actual low-dose dark-field images. Methods: Dark-field radiographs of an anthropomorphic chest phantom were acquired at different tube currents equaling different radiation doses. Based on the measurement with a high radiation dose, dark-field radiographs corresponding to lower radiation doses were simulated by virtually reducing the irradiated area. The simulated low-dose radiographs were evaluated by a quantitative comparison of the dark-field signal using different regions of interests. Results: Dark-field radiographs acquired at one quarter of the standard dose were artifact-free. The dark-field signal differed from the simulated radiographs by up to 10%. Algorithm-induced stripe artifacts decrease the image quality of the simulated radiographs. Conclusions: Virtually reducing the irradiation area is a simple approach to generate low-dose radiographs based on images acquired with scanning-based dark-field radiography. However, as the algorithm creates stripe artifacts in the dark-field images, particularly at higher dose reductions, that are not present in measured low-dose images, simulated images have reduced image quality compared to their measured counterparts.2025-08-21T07:42:38ZHenriette BastRafael C. SchickThomas KoehlerFranz Pfeiffer10.1016/j.zemedi.2025.12.007http://arxiv.org/abs/2508.15309v1T2 Radiomic Features Are More Sensitive Than Mean T2 for Cartilage Load Response: A Stress MRI Study2025-08-21T07:05:43ZObjective: To assess response-to-loading in a human cadaveric knee joint model under different loading conditions before and after meniscectomy
Design: In this prospective study, stress magnetic resonance imaging was performed using an MR-compatible loading device and quantitative T2 mapping in unloaded (UL), 0$°$ neutrally loaded (LN) and 10$°$ varus loaded (LV) condition before and after meniscectomy. Mean T2 values and four radiomic texture parameters were assessed within the cartilage of medial femur (MF) and medial tibia (MT) for all conditions.
Results: Medial joint space width decreased from UL to LN to LV and after meniscectomy (all p<0.05). T2 values did not show any significant dependency on pressure or meniscectomy (all p>0.05). The radiomic parameter variance could assess loading induced textural T2 changes in the MF (UL vs. LN: p=0.042; UL vs. LV: p<0.001; LN vs. LV: p=0.022), and, in part, in the MT (LN vs. LV: p<0.013). Meniscectomy did not significantly alter the T2 mean values or radiomic parameters, respectively.
Conclusions: T2-based radiomic features were more sensitive to assess cartilage response to loading than T2-mapping alone.2025-08-21T07:05:43Z12 pages (main manuscript text), 4 tables, 5 figures, 3 supplementary figuresTeresa LemainquePhilipp SchadSimon WestfechtelMarc von der StückRobert SiepmannAxel HonnéChristiane KuhlDaniel TruhnSven Nebelunghttp://arxiv.org/abs/2509.02573v1Materials and Design Strategies of Fully 3D Printed Biodegradable Wireless Devices for Biomedical Applications2025-08-21T05:45:51ZThree-dimensional (3D) printing of bioelectronics offers a versatile platform for fabricating personalized and structurally integrated electronic systems within biological scaffolds. Biodegradable electronics, which naturally dissolve after their functional lifetime, minimize the long-term burden on both patients and healthcare providers by eliminating the need for surgical retrieval. In this study, we developed a library of 3D-printable, biodegradable electronic inks encompassing conductors, semiconductors, dielectrics, thereby enabling the direct printing of fully functional, multi-material, customizable electronic systems in a single integrated process. Especially, conjugated molecules were introduced to improve charge mobility, energy level alignment in semiconducting inks. This ink platform supports the fabrication of passive/active components and physical/chemical sensors making it suitable for complex biomedical applications. Versatility of this system was demonstrated through two representative applications: (i) wireless pressure sensor embedded within biodegradable scaffolds, (ii) wireless electrical stimulators that retain programmable electrical functionality in vivo and degrade post-implantation. This work establishes a foundation of modules for autonomous, biodegradable bioelectronic systems fabricated entirely via 3D printing, with implications for personalized diagnostics, therapeutic interfaces, and transient medical devices.2025-08-21T05:45:51Z50 pages, 7 figuresJu-Yong LeeJooik JeonJoo-Hyeon ParkSe-Hun KangYea-seol ParkMin-Sung ChaeJieun HanKyung-Sub KimJae-Hwan LeeSung-Geun ChoiSun-Young ParkYoung-Seo KimYoon-Nam KimSeung-Min LeeMyung-Kyun ChoiJun Min MoonJoon-Woo KimSeung-Kwon SeolJeonghyun KimJahyun KooJu-Young KimWoo-Byoung KimKang-Sik LeeJung Keun HyunSeung-Kyun Kanghttp://arxiv.org/abs/2508.15254v1Dosimetric Evaluation of MapCHECK in MapPHAN for Conformal Arc SABR Quality Assurance2025-08-21T05:36:46ZThis study investigates the sensitivity and specificity of the MapCHECK phantom housed in MapPHAN to errors in conformal arc Stereotactic Ablative Body Radiotherapy (SABR). A specific focus is applied to Organ At Risk (OAR) dosimetry. Multi-Leaf Collimator (MLC) class shift errors up to 2 mm, and isocentre shift errors of up to 1 mm, were introduced to 23 simulated 6 MV X-ray conformal arc lung SABR plans in Raystation. Overall, 198 plans were delivered on a Varian Clinac iX linear accelerator to an in-house modified MapCHECK in MapPHAN. Gamma analysis was used to compare the MapCHECK measurements to the simulated Raystation plans. Receiver Operating Characteristic (ROC) curves were generated from these results to determine the sensitivity and specificity of the measurement technique to the introduced errors. For MapCHECK in MapPHAN, a combination of 5%/1 mm with 95% gamma tolerance and 2%/1 mm with 90% tolerance provides good sensitivity and specificity for Quality Assurance (QA) of conformal arc SABR plans.2025-08-21T05:36:46ZNathan I. N. HenryChristopher M. ThompsonSteven MarshJack D. Aylward