https://arxiv.org/api/ZYnF/ogCUi33BXKjBWVhPjzkAKE 2026-09-10T17:24:14Z 9200 0 15 http://arxiv.org/abs/2609.10458v1 Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose 2026-09-09T17:06:39Z The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study. 2026-09-09T17:06:39Z Parmita Mondal Rickey Carter Andrew D Missert Akitoshi Inoue Joel G. Fletcher Hao Gong Shuai Leng Lifeng Yu Cynthia H. McCollough Scott S. Hsieh http://arxiv.org/abs/2608.10673v2 Real-Time Requirements and Transferability in Compton Imaging: From the Detector Chain to the Application 2026-09-09T14:46:09Z Compton cameras are proposed for tasks whose value decays with delay: verifying a range during irradiation, guiding an intervention, characterising an inaccessible volume, surveying a band no telescope covers. Whether a device can serve such a task is settled by the composition of its whole chain, while the literature that would answer the question is organised by stage -- so claims made at application level routinely rest on evidence obtained at component level. This review walks that chain, asking at each stage what binds first and what a reader can determine from the published text, and then asks what governs whether a capability transfers between groups and between application domains. The evidence is of two kinds: 83 full texts scored in context against defined markers, and, for five application domains measured alike, the size of the receiving literature, of the need it states, of the incumbent and of deployment commitment. Performance is reported at one operating point in 65 of 83 full texts, with count rate swept in none: the field reports values where transfer requires gradients. An accelerator is used in 39 works and a learned model in 31, while separability is discussed in 28, a memory footprint given in 9, and the cost of a precomputation or the inference time of a model in none. Across domains, neither the size of the receiving literature, nor of the incumbent, nor of the stated need orders the domains as deployment commitment does, while whether the incumbent can serve the task at all, and how many domain boundaries the output must cross, do so consistently. The distribution of publication is close to the inverse of the distribution of deployment commitment. We give the quantities a report must contain for a third party to judge whether a method fits an application it was not built for. 2026-08-11T08:55:28Z 32 pages, 5 figures, 5 tables. Supplementary data (marker definitions, per-work screening matrix and database queries with dates and counts) included as ancillary files F. Albiol Elena Larrea Estrelles Salvador Tortajada Luis Caballero Jose Escalante Alberto Albiol Jose Luis Leganes-Nieto http://arxiv.org/abs/2504.03899v2 A novel methodology to estimate pileup effects and induced error in microdosimetric spectra 2026-09-09T14:32:43Z Microdosimetry provides a superior characterization of the radiation field compared to conventional LET-based methodology, and for this reason it has become increasingly attractive for quality assurance in particle therapy. However, the typical particle rates used in the treatments lead to pileup, which distorts the experimental spectra, and thus compromises the accuracy of microdosimetric measurements, limiting their use in clinical settings. In this work, we investigated the pileup in a spherical Tissue Equivalent Proportional Counter (TEPC), and developed an algorithm to evaluate the contribution of this effect to the measured spectra. We exposed the TEPC to 11 and 70 MeV proton beams, and collected the microdosimetric spectra at rates in the $10^3$-$10^6$ pps range. Using a combination of GEANT4 Monte Carlo simulations and experimental data, we develop an algorithm capable of estimating the pileup probability affecting experimental measurements. The data suggest that the pileup probability has a linear increase with rate until it reaches a value of $15 \pm 3 \, \%$ at $28.2 \times 10^3$ pps, at which point it begins to saturate. Additionally, the outcomes from the comparison of the two proton energies suggest that the methodology used to estimate pileup can be used to predict the effects in clinical proton beams with similar energies. This same methodology can be applied to any type of microdosimetric measurement making it a reliable tool for addressing pileup issues and facilitating the application of microdosimetry in clinical settings. 2025-04-04T19:41:17Z E. Pierobon M. Missiaggia F. G. Cordoni C. La Tessa http://arxiv.org/abs/2410.21948v8 Conceptualization of electronic dose to water and water-equivalent gas for ionometric dosimetry in external beam radiotherapy 2026-09-09T13:39:06Z Electronic dose to water, which is the radiant energy imparted to a unit mass of water by electronic collisions, is conceptualized to exclude corrections and uncertainties associated with energy transfer to atomic nuclei and to enhance medical relevance in radiotherapy dosimetry. Based on the international code of practice, the procedures to determine electronic doses were formulated for high-energy photon, electron, proton, and ion beams. Nitrogen-based water-equivalent gas (WEG) mixtures were designed for use in gas-sealed ionization chambers for proton and ion beams. A thought experiment of reference dosimetry for electronic dose demonstrated its compatibility with absorbed dose for photon and electron beams. For proton and ion beams, the transition from absorbed dose to electronic dose will change the measured dose values by -1.4% and -2.2%, and decrease the uncertainty from 1.6% to 1.5% and from2.6% to 2.1%, respectively. With WEG ionization chambers, the uncertainty will further decrease to 1.2% for proton beams and 1.5% for ion beams. The formulated framework will be applicable to radiotherapy dosimetry with traceable dosimeter calibration under the international measurement system for radiation metrology. 2024-10-29T11:06:42Z 11 pages, 6 tables, 2 figures Nobuyuki Kanematsu http://arxiv.org/abs/2607.20136v2 PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping 2026-09-09T08:21:25Z Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions. 2026-07-22T13:39:40Z Busra Bulut Maik Dannecker Thomas Sanchez Sara Neves Silva Steven Jia Jean-Baptiste Ledoux Leo Pomar Joanna Sichitiu Yvan Gomez Meriam Koob Vincent Dunet Maria Deprez Guillaume Auzias Francois Rousseau Jana Hutter Daniel Rueckert Meritxell Bach Cuadra http://arxiv.org/abs/2609.09455v1 Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods 2026-09-08T21:11:16Z Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction. 2026-09-08T21:11:16Z Yuhao Wang Zhendong Zhang Edward Robert Criscuolo John Ginn Ke Lu Yao Hao Deshan Yang http://arxiv.org/abs/2609.08814v1 Evaluating the predictive power of pump-probe imaging contrast of melanin for metastatic outcome: A 71-patient study 2026-09-08T14:40:32Z Significance: Most melanoma deaths arise from metastatic spread, yet current staging imperfectly identifies which primary tumors will progress. Melanin structure is altered during malignant transformation, and pump-probe microscopy (PPM) measures melanin excited-state dynamics in standard biopsy sections, offering molecular contrast that is complementary to morphology-based assessment. Aim: To determine whether PPM-derived melanin excited-state dynamics in primary cutaneous melanoma can predict metastatic outcome. Approach: We imaged unstained sections from 71 primary cutaneous melanomas and 18 melanoma metastases. Transient absorption curves were fit to a biexponential excited-state model, and the fit parameters were used as features for learning classifiers to predict metastatic outcome. Results: Melanin dynamics separated primary from metastatic tissue: both excited-state lifetimes were shorter in primaries, with common-language effect sizes up to 0.26. The same parameters did not separate primary tumors by outcome (effect sizes 0.41-0.61), and univariate logistic regression found no significant association for either the excited-state lifetimes or the ESA/GSB ratio. The best classifier reached 74% patient-level accuracy (AUC 0.73), a plateau reached by several unrelated architectures. Conclusions: PPM robustly distinguishes primary from metastatic melanoma tissue, consistent with progressive melanin disaggregation. While it is clear that pump-probe features of melanin thus correlate with tissue differences, melanin dynamics in single sections of the primary tumor, confounded by heterogeneity, do not give robust predictions of metastatic outcome. 2026-09-08T14:40:32Z David Grass Emma Bao Martin C. Fischer M. Angelica Selim Georgia M. Beasley Warren S. Warren http://arxiv.org/abs/2605.20470v2 EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis 2026-09-08T12:42:16Z Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows. The open source code for EPC-3D-Diff is available at https://github.com/ALZAHRAALTALIB/EPC-3D-Diff. 2026-05-19T20:34:09Z 10 pages, 4 figures Medical Image AI in Radiation Therapy (MIART), MICCAI 2026 Alzahra Altalib Chunhui Li Haytham Ahmad Alewaidat Khaled Z. Alawneh Ahmad Awad Qandeel Alessandro Perelli http://arxiv.org/abs/2609.08030v1 Reducing Hydrocephalus Shunt Revision Rates: A Computational Fluid Dynamics Study on Catheter Hole Design 2026-09-07T22:27:25Z Proximal shunt obstruction is the leading cause of ventriculoperitoneal (VP) shunt failure in pediatric hydrocephalus and is closely tied to the near-wall shear environment at drainage holes. We used computational fluid dynamics (COMSOL) to decouple local wall-shear-stress (WSS) control via catheter-tip geometry from global drainage control via a valve opening. A cylindrical ventricle domain with Newtonian CSF ($ρ$ = 1000 kg/m$^3$, $μ$ = 1 mPa$\cdot$s) and $ΔP \approx$ 10 mmHg was solved under laminar Navier-Stokes flow while sweeping distal hole spacing, hole count/diameter, and a simplified valve constriction. Mesh-independence was achieved (minimum element size $\approx$ 0.021 mm; distal-hole velocity converged to $\approx$ 1.18$\times10^{-3}$ m/s). Perpendicular separation of the two most distal holes increased total outflow by $\approx$ 22% (2 mm vs 0.5 mm) and raised distal lateral-wall WSS by $\approx$ 19%, whereas longitudinal shifts of upstream holes produced only small changes. A valve opening near 0.166-0.17 mm set system drainage to $\approx$ 20 mL/h across geometries, indicating capacity is valve-limited while local WSS is geometry-controlled. The selected tip uses two conical holes (0.5 mm ID) in four rows with 1.4 mm spacing, concentrating WSS at the distal lateral walls, the surfaces where obstruction occurs, without exceeding clinical drainage targets. These findings yield design rules: prioritize distal-pair spacing, reduce hole count with smaller conical openings to elevate protective WSS, and regulate outflow with the valve. The framework provides a clear path to benchtop validation, long-term adhesion assays under mapped WSS, and anatomically realistic CFD. 2026-09-07T22:27:25Z Omar Said Mingzi Li Hanyu Gan http://arxiv.org/abs/2505.18782v10 Joint Reconstruction of Activity and Attenuation in PET by Diffusion Posterior Sampling in Wavelet Coefficient Space 2026-09-05T12:05:12Z Attenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography (CT) or magnetic resonance (MR) scan. However, this additional scan may complicate the imaging workflow, introduce misalignment artifacts and increase radiation exposure. In this paper, we propose a joint reconstruction of activity and attenuation (JRAA) approach that eliminates the need for auxiliary anatomical imaging by relying solely on emission data. This framework combines wavelet diffusion model (WDM) and diffusion posterior sampling (DPS) to reconstruct fully three-dimensional (3-D) data. Experimental results on simulated data show our method outperforms maximum likelihood activity and attenuation (MLAA) and MLAA-UNet with U-Net-based postprocessing, and yields high-quality noise-free reconstructions across various count settings with time-of-flight (TOF). It is also able to reconstruct non-TOF data, although the reconstruction quality significantly degrades in low-count (LC) conditions, limiting its practical effectiveness in such settings. Nonetheless, a non-TOF Biograph mMR real data reconstruction with joint scatter estimation highlights the potential of the method for clinical applications. This approach represents a step towards stand-alone PET imaging by reducing the dependence on anatomical modalities while maintaining quantification accuracy, even in LC scenarios when TOF information is available. Our code is available on GitHub at https://github.com/clemphg/jraa-dps. 2025-05-24T16:39:50Z 16 pages, 10 figures, 8 tables Clémentine Phung-Ngoc Alexandre Bousse Antoine De Paepe Thibaut Merlin Baptiste Laurent Hong-Phuong Dang Olivier Saut Catherine Cheze-Le-Rest Dimitris Visvikis 10.1109/TRPMS.2026.3706239 http://arxiv.org/abs/2609.05931v1 Distinct Radiobiological Responses to BNCT in SAS Oral Squamous Cell Carcinoma and MCF-7 Breast Cancer Cells 2026-09-05T06:40:12Z This work compared the radiobiological responses of SAS oral squamous cell carcinoma cells and MCF-7 breast cancer cells following accelerator-based boron neutron capture therapy (BNCT). Neutrons were generated by bombarding a lithium target with proton beams, followed by moderation to obtain sufficient thermal neutrons for BNCT irradiation. Boronophenylalanine (BPA) was used as the boron delivery agent. BNCT-induced biological responses were evaluated by gamma-H2AX immunofluorescence staining, cell-cycle analysis, apoptosis analysis, and clonogenic survival assays. BNCT induced marked gamma-H2AX foci formation in both cell lines, indicating DNA damage-associated responses after irradiation. The two cell lines further showed distinct post-irradiation outcomes. SAS cells exhibited stronger clonogenic suppression and prominent G2/M accumulation, whereas MCF-7 cells showed sustained G0/G1 accumulation and delayed apoptosis. These results suggest that BNCT sensitivity is determined by both boron accumulation and cell-line-specific biological characteristics. This work provides experimental evidence highlighting the importance of tumor-dependent cellular responses in understanding and optimizing BNCT efficacy. 2026-09-05T06:40:12Z 10 pages, 6 figures, 1 table; supplementary information included Yuxiang Zhao Zhao Sun Changming Wang Jianghao Lai Jie Zhou Zhencen He Zhimin Hu http://arxiv.org/abs/2608.13772v3 Fully Fiber-Integrated 3D-Printed Probes for Plug-and-Play Endoscopic Optical Coherence Tomography 2026-09-04T22:19:31Z Miniature probes extend optical coherence tomography (OCT) into lumens and other confined spaces, but conventional implementations often rely on multiple distal components, fiber processing, and probe-specific interferometer matching. Here, a fully fiber-integrated OCT (F2I-OCT) architecture is demonstrated in which two-photon microfabrication defines not only the terminal imaging optic, but the complete distal optical and interferometric architecture within a single fiber-mounted element. Beam expansion, side-view redirection, common-path reference generation, and terminal imaging are physically integrated while remaining independently designable. This architecture transfers complexity from component fabrication and interferometer matching into three-dimensional optical design, reducing assembly to a print-and-bond process and enabling plug-and-play exchange on the same OCT platform. Terminal optics can be adapted to different working distances, surrounding media, and wavefront transformations without redesigning the upstream architecture. Twenty assembled probes exhibit returned-reference and side-viewing-output power standard deviations of 0.149 dB and 0.071 dB, respectively. The system achieves 93.1 dB sensitivity and enables ex vivo imaging of airway and dental structures. The combination of a common plug-and-play architecture with broad optical design freedom provides a versatile platform for endoscopic and confined-space imaging across diverse biomedical and technical environments. 2026-08-13T20:58:44Z Yihan Wang Ruilin You Jiabin Chen Bofan Song Zien Feng Paula Patricia Villarreal Gracie Vargas Rongguang Liang http://arxiv.org/abs/2609.05706v1 A unified dielectric-tensor model of macular form birefringence and dichroism 2026-09-04T20:25:10Z Optical anisotropy of the Henle fiber layer (HFL) underlies two macular polarization phenomena, form birefringence (the macular cross) and dichroism (Haidinger's brushes), which have conventionally been treated as unrelated. We model the HFL as a radial diattenuating retarder and derive a single complex dielectric tensor: effective-medium theory for parallel cylinders gives the real part, and cylindrical averaging of the measured transmembrane xanthophyll tilt gives the imaginary part. The birefringent slow axis is radial and the absorption axis tangential, perpendicular by structural necessity. The model reproduces measured dichroic ratios of 1.04--1.14 for a single calibrated oriented-pigment fraction, and supplies the input parameters for full electromagnetic treatments. 2026-09-04T20:25:10Z Gary P. Misson Dusan Sarenac Dmitry. A. Pushin Shelby E. Temple http://arxiv.org/abs/2510.11670v3 Collagen and myocyte interplay in cardiac volume overload: a multi-constituent growth and remodeling framework 2026-09-04T14:51:52Z Hearts subjected to volume overload (VO) are prone to detrimental anatomical and functional changes in response to elevated mechanical loading, ultimately leading to heart failure. Experimental findings now emphasize that organ-scale changes following VO cannot be explained by myocyte growth alone, as traditionally proposed in the literature. Collagen degradation, in particular, has been associated with VO and assumed to play a central role in both its acute and chronic stages. This hypothesis, however, remains to be substantiated by comprehensive mechanistic evidence, and each constituent contribution to myocardial growth and remodeling (G&R) processes is yet to be quantified. In this work, we present a multi-constituent G&R framework that integrates a mixture-based constitutive model within the kinematic growth formulation. This framework enables us to mechanistically assess the relative contributions of collagen and myocyte changes to alterations in tissue properties, ventricular dimensions, and growth phenotype. Our numerical results confirm that collagen remodeling affects the passive mechanical response of the myocardium, whereas myocytes predominantly influence the extent and phenotype of VO-induced growth. Importantly, collagen degradation exacerbates myocyte hypertrophy, revealing a synergistic interplay that accelerates the left ventricular eccentric growth and thereby promotes systolic dysfunction. This work constitutes an important step towards an integrated characterization of the early compensatory stages of VO-induced cardiac G&R. 2025-10-13T17:43:08Z Ludovica Maga Mathias Peirlinck Lise Noël http://arxiv.org/abs/2609.04891v1 Attention-guided super-resolution of 4D flow MRI in carotid arteries 2026-09-04T08:48:32Z Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment. 2026-09-04T08:48:32Z Ali Mokhtari Dominik Obrist