https://arxiv.org/api/ZYnF/ogCUi33BXKjBWVhPjzkAKE 2026-05-15T23:44:08Z 8899 0 15 http://arxiv.org/abs/2605.12558v2 Voxel-aware oxygen kinetics resolves radiation-induced DNA damage retention across LET-oxygen conditions 2026-05-14T16:42:39Z Objective. Hypoxic tumor subvolumes resist radiation through elevated oxygen enhancement ratios (OER), yet no computational OER model is simultaneously particle-specific, mechanistically grounded, and fast enough for voxel-scale treatment planning. We present the VOxel-Aware Oxygen Model (VOxA) to address all three requirements. Approach. An Oxygen Model (OM) encodes particle-specific LET-OER dependence through dual sigmoidal transitions constrained to increase monotonically with atomic number Z, combined with Michaelis-Menten oxygen kinetics. A Voxel-Aware (VA) extension resolves per-DSB local energy heterogeneity via a calibrated particle-specific sensitivity parameter. Calibrated on 233 OER observations from 29 sources across 10 particle types (LET = 0.2-654 keV/um); DSB coordinates from TOPAS-nBio simulations. Main results. The OM achieves $R^2 = 0.719$ and MAE = 0.300 retention OER units; theoretical OER maximum 3.32 (2.4% from measurement), bootstrap median 3.37 [3.18, 4.09]. The composite $K_{\rm fix} + K_{\rm repair} = 2.82$ mmHg is tightly constrained despite high collinearity (r = 0.935). On the Furusawa heavy-ion subset, VOxA achieves 28.4% lower survival OER MAE than the clinical standard (63.1% on helium, 24.0% on carbon) and reproduces He < C < Ne Z-ordering that universal models cannot capture. The VA extension passes 18 tests confirming sample-size-invariant within-nucleus coefficient of variation of the per-DSB retention probability. VOxA evaluates in under $10^{-3}$ ms per voxel, more than $10^6$ times faster than Monte Carlo chemistry. Significance. VOxA is the first particle-specific OER model to reproduce Z-ordering analytically at clinical planning speed, validated on the largest OER calibration dataset for this model class. Committed-break coordinates at whole-nuclear scale provide the input for inter-break topological analysis and hypoxic LET painting. 2026-05-11T15:00:31Z Renato III Fernan Bolo Ramon Jose C. Bagunu http://arxiv.org/abs/2605.14987v1 A Monte Carlo positronium decay source model with multiple annihilation channels in GATE 2026-05-14T15:49:19Z Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the definition of an arbitrary number of decay channels characterised by lifetime, branching fraction, annihilation multiplicity (2g/3g), and optional prompt photon emission. The model is validated through analytical and numerical benchmarks, including lifetime distributions, branching fraction consistency, photon kinematics, and prompt photon emission. Its practical applicability is demonstrated using simulations of mixed annihilation scenarios and the NEMA IEC phantom with a large field-of-view PET system. The proposed model accurately reproduces input lifetime distributions as weighted sums of exponential components and correctly samples decay channel fractions. Simulated two- and three-photon annihilation kinematics are consistent with theoretical expectations. Complex mixtures of decay channels, including varying 3g-to-2g ratios and multi-component ortho-positronium lifetimes, are correctly modelled, with observable signatures reflected in both temporal and energy distributions. Phantom simulations demonstrate the capability to generate realistic positronium-sensitive datasets. This work provides the first general-purpose, multi-channel positronium decay model integrated into GATE, enabling realistic simulations of positronium behaviour in complex media. The model supports the development and optimisation of positronium-based imaging techniques, including PLI and multi-photon PET, and applies to medical imaging, industrial tomography, and fundamental physics studies. Its public availability and compatibility with standard GATE workflows make it a valuable tool for the broader research community. 2026-05-14T15:49:19Z 24 pages, 12 figures Wojciech Krzemien Mateusz Bala Kamil Dulski Wojciech Zdeb Aurélien Coussat Beatrix C. Hiesmayr Konrad Klimaszewski Michał Obara Lech Raczyński Roman Y. Shopa http://arxiv.org/abs/2605.13555v1 Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report 2026-05-13T13:59:03Z Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE $64.8\pm21.3$ HU, PSNR $\sim$30 dB, MS-SSIM $\sim$0.936, Dice 0.79, photon $γ_{2\%/2\text{mm}}>98\%$, proton $γ\approx85\%$. Task 2 improved: MAE $48.3\pm13.4$ HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon $γ>99\%$, proton $γ\approx89\%$. Strong image--segmentation correlations ($ρ=0.78$--$0.79$) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation. 2026-05-13T13:59:03Z 59 pages total: 26 pages main article + supplementary material; 8 figures in the main manuscript and 3 supplementary figures. Currently under review at the journal Medical Image Analysis (MIA) Viktor Rogowski Maarten L. Terpstra Niklas Wahl Florian Kamp Erik van der Bijl Arthur Jr. Galapon Christopher Kurz Bowen Xin Zhengxiang Sun Hollie Min Gregg Belous Jason Dowling Yan Xia Siyuan Mei Fuxin Fan Arthur Longuefosse Javier Sequeiro Gonzalez Miguel Diaz Benito Alvaro Garcia Martin Fabien Baldacci Valentin Boussot Cédric Hémon Jean-Claude Nunes Jean-Louis Dillenseger Zhiyuan Zhang Jinghua Cai Han Bing Tan Zuopeng Ricardo Brioso Daniele Loiacono Guillaume Landry Adrian Thummerer Matteo Maspero http://arxiv.org/abs/2603.05658v2 Ultra-high frequency ultrasound imaging and quantification of microvascular flow in xenograft renal cell carcinoma in an avian chorioallantoic membrane model 2026-05-13T13:01:28Z Patient derived xenograft (PDX) tumor models initiated in avian chorioallantoic membranes (CAM) are under investigation to evaluate the effectiveness of therapeutic options with the objective of personalizing treatments. CAM PDXs paired with ultra-high frequency ultrasound (UHFUS) imaging could potentially constitute prospective high throughput assays that can rapidly assess tumor volume and vascular response to therapy. To date, little work has been conducted to adapt and validate UHFUS flow imaging methods to CAM tumor models. Here we report the development and evaluation of an imaging pipeline for UHFUS detection of microvascular flow in a CAM tumor model using interframe subtraction (IS) to suppress tissue clutter. The IS pipeline included a tissue motion compensation (MC) stage prior to clutter filtering and was compared to a singular value decomposition (SVD) clutter filter. The performance was evaluated using UHFUS data acquired in phantom and in vivo Sunitinib-treated renal cell carcinoma. MC substantially reduced tissue motion effects. MC+IS was comparable to MC+SVD filtering at detecting flow within tumors. The results for both IS and SVD filters were dependent on the details of implementation. The UHFUS imaging methods detected a significant decrease in blood flow metrics in treated versus control tumors. An effective imaging pipeline was developed for the assessment of the treatment response of CAM PDX models in a clinically relevant timeframe. The MC+IS approach implemented on B-scan image derived data is less computationally intensive and can be used with widely available UHFUS systems. 2026-03-05T20:19:50Z 38 pages, 10 figures, 5 supplementary figures, 2 supplementary videos (available on request from corresponding author) Sara Mar Emmanuel Cherin Justin Xu David E. Goertz Hon S. Leong Christine E. M. Demore http://arxiv.org/abs/2407.06527v3 Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast 2026-05-13T04:52:48Z Many lung diseases require detailed visualisation for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interfaces. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure of $<2.5\:\text{mSv}$ effective dose. Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT. Phase retrieval enabled clear visualisation of minor lung airways at doses up to 1,225$\pm$31\% times lower than conventional CT reconstruction, at a voxel size of just 75$\mathrmμ$m. 2024-07-09T03:54:10Z Updated to match published version James A. Pollock Kaye Morgan Linda C. P. Croton Emily J. Pryor Kelly J. Crossley Christopher J. Hall Daniel Hausermann Anton Maksimenko Stuart B. Hooper Marcus J. Kitchen http://arxiv.org/abs/2301.12647v3 3DMPR -- A robust morphological approach for applying phase retrieval in proximity to highly-attenuating objects in CT 2026-05-13T02:20:52Z X-ray imaging is a fast, precise and non-invasive method of imaging which, when combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via phase retrieval, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material samples commonly requires choice of which material boundary to tune the reconstruction. Selecting the boundary with strongest phase contrast increases noise suppression, but at the detriment of over-blurring other interfaces and potentially removing quantitative sample information. Additionally, conventional phase-retrieval algorithms cannot be used for regions bounded by more than one material, requiring alternative methods. Here we present a computationally-efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. 3D phase retrieval is combined with morphological operations to prevent over-blurring artefacts from being introduced, while avoiding the potentially long convergence times required by iterative approaches. This technique, entitled 3DMPR, was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24kVp synchrotron radiation with a 5m propagation distance, 3DMPR provided a 6.8-fold improvement in the signal-to-noise ratio (SNR) of brain tissue over the standard phase retrieval procedure, without over-smoothing the images. 2023-01-30T03:59:42Z Updated to match published version J. A. Pollock L. C. P. Croton K. S. Morgan K. J. Crossley M. J. Wallace G. A. Buckley S. B. Hooper M. J. Kitchen http://arxiv.org/abs/2605.12896v1 Large Language Models for AI-Assisted Radiotherapy Scheduling: A Feasibility Study Under Realistic Operational Constraints 2026-05-13T02:18:17Z Radiotherapy (RT) patient scheduling is a complex operational problem. Current scheduling often relies on manual coordination and can be difficult to adapt to changing clinical demands. This study evaluated the feasibility of using a large language model (LLM) to generate candidate RT patient schedules satisfying predefined clinical and operational constraints. A simulated three-LINAC RT scheduling environment was developed over one year using synthetic patient arrivals and treatment characteristics modeled after clinical practice. A total of 1,400 new patients across 12 treatment categories were generated. An LLM-based scheduling framework used structured natural-language prompts encoding clinical rules, operational constraints, and scheduling objectives. Performance was evaluated across scenarios involving weekly time consistency, LINAC continuity, gap-constrained temporal relaxation, and infeasible request handling. Generated schedules were validated using deterministic rule-based checks and manual review. LLM-generated schedules satisfied predefined feasibility rules in the evaluated scenarios. Approximately 99% of evaluated fractions remained within the preferred 60-minute weekly treatment-time window. Adding a LINAC-continuity objective reduced LINAC switching from 54.6% to 10.1%. Adding gap-constrained temporal relaxation reduced Friday mean daily gap time from 169.5 to 89.2 minutes while maintaining approximately 99% of fractions within the 60-minute window. The framework also identified infeasible scheduling requests and proposed interpretable corrective actions. These results suggested that LLMs may support RT patient scheduling in constraint-rich simulated clinical environments, motivating further investigation of LLM-assisted scheduling as a flexible, human-in-the-loop decision-support approach for RT operations. 2026-05-13T02:18:17Z 34 pages, 4 figures, 6 tables Eric Zhang Wen Li Youfang Lai Annette Souranis Georgia Paparoidamis Michael Roumeliotis Xun Jia http://arxiv.org/abs/2605.12891v1 Dynamic Modulated Arc Therapy (DMAT): An Intent-Driven, Time-Aware Framework for Next-Generation Radiotherapy Delivery 2026-05-13T02:14:37Z Traditional VMAT optimization often ignores dynamic machine limits, treating delivery time as an emergent property rather than a steerable parameter. This work introduces Dynamic Modulated Arc Therapy (DMAT), an intent-driven framework that jointly co-optimizes dosimetric quality, delivery time, and modulation complexity. DMAT couples machine emulation accounting for axis synchronization and finite acceleration with dynamic modulation control and clinical cost functions. A user-selected level (-3 to +3) governs leaf-travel, MU behavior, and CP density. Plans are created by initializing CP geometry, leaf positions, and MU, then iteratively alternating dosimetric updates with sequencing updates (penalties for motion, velocity changes, MU uniformity, and complexity), followed by post-processing. CP density is adapted by first optimizing with a uniform distribution and then redistributing CPs to arc sectors with higher complexity. DMAT was evaluated using a hypothetical system (2.5 RPM gantry, 6.25 cm/s MLC, 3000 MU/min) on H&N, lung SBRT, and prostate SBRT cases. Higher modulation levels produced increased MU/Gy and longer delivery times, while adaptive CP allocation concentrated resolution in high-reward sectors. H&N cases showed substantial quality gains with increased modulation, whereas prostate and lung SBRT exhibited smaller incremental improvements. When efficiency was prioritized (negative levels), DMAT reduced modulation and maintained a constant CP budget while shortening delivery time, producing quantifiable reductions in plan quality. DMAT enables intent-driven planning where quality and complexity are co-optimized via machine-aware timing. Accurate delivery time is exposed during planning, making trade-offs transparent and navigable for next-generation systems and time-constrained workflows like motion-sensitive or adaptive radiotherapy. 2026-05-13T02:14:37Z Taoran Li Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Esa Kuusela Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Emmi Ruokokoski Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Heini Hyvönen Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Jerry Jaboin Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Mirko Myllykoski Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Jussi Nurminen Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Riku Paananen Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Jarkko Peltola Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Marko Rusanen Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Martin Sabel Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Kevin Moore Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA Christopher Boylan Varian Medical Systems Inc. - a Siemens Healthineers company, Palo Alto, USA http://arxiv.org/abs/2604.27418v3 MAAS-SFRThelper: An Integrated ESAPI Plugin for Structure Generation, Optimization, and Evaluation of Spatially Fractionated Radiation Therapy 2026-05-12T15:56:48Z Spatially fractionated radiation therapy (SFRT) planning requires three coordinated tasks: generation of high-dose sphere structures, position-aware optimization, and peak-valley dose ratio evaluation. We present MAAS-SFRThelper, a shared-source Eclipse Scripting Application Programming Interface (ESAPI) plugin that integrates structure generation, geometric-aware optimization, and peak-valley dose ratio evaluation for SFRT into a single workflow inside Varian's Eclipse treatment planning system. The plugin exposes five task-oriented tabs sharing common services for sphere extraction and objective creation. The SphereLattice tab generates sphere lattices using five placement patterns. The Optimization tab searches over candidate lattice positions using a four-metric geometric surrogate score and triggers VMAT optimization and dose calculation. The Evaluation tab implements four analysis modes; its three-dimensional peak-valley classification recovers sphere centers from the lattice structure through a geometric extraction pipeline rather than relying on dose thresholds. We validated all functionality on digital phantoms against analytic ground truth. The plugin is distributed as source code under the Varian Limited Use Software License Agreement. Source code and documentation are publicly available on GitHub. 2026-04-30T04:48:38Z Manuscript is being submitted to JACMP for review Japan K. Patel Todd A. Wareing Tenzin Kunkyab Caleb Raman Ilias Sachpazidis Peter Szentivanyi Ryan Clark Gregory Gill Pierre Lansonneur Arjun Karnwal Michael Kudla Sergejs Unterkirhers Junqi Song Jun Yang Anthony Magliari Matthew C. Schmidt http://arxiv.org/abs/2605.12164v1 A Comparative Analysis of CT Degradation for LDCT Nodule Classification using Radiomics 2026-05-12T14:13:32Z Low-dose computed tomography (LDCT) is the standard modality for lung cancer screening, known for its low radiation dose but high noise levels. While existing literature focuses on denoising LDCT images, comparative research on simulating LDCT characteristics to directly use these images for model development is lacking. This study shifts the focus from denoising images to degrading available standard-dose CT (SDCT) data, generating synthetic images for data augmentation to train classifiers for screening-detected nodules. We compare three degradation methods: (1) a sinogram domain statistical noise insertion; (2) replicate a validated physics-based simulation using Pix2Pix; and (3) unpaired CycleGAN. The generated images were utilized to simulate LDCT screening scenario replacing 695 SDCT cases from the LIDC-IDRI dataset, from which radiomic features were extracted to train machine learning models for lung nodule classification. Regarding image quality, CycleGAN achieved the best Fréchet inception distance (0.1734) and kernel inception distance (0.0813; 0.1002) scores, indicating distributional alignment with the target low-dose domain. In the nodule classification task, results confirmed the necessity of domain adaptation since a baseline model trained on non-degraded SDCT data failed to generalize to the real LDCT set (AUC 0.789) with a low sensitivity (0.571). Degraded images generated using CycleGAN approach led to the most balanced performance on the classification task using Adam Booster classifier, achieving an AUC of 0.861, sensitivity of 0.743 and specificity of 0.858 in the independent test. Our findings confirm that generating synthetic LDCT data from standard-dose scans is a viable strategy for training robust nodule classifiers for screening detected nodules. 2026-05-12T14:13:32Z Jiaying Liu Anna Corti Valentina D. A. Corino Luca Mainardi http://arxiv.org/abs/2605.11829v1 Bin Latent Transformer (BiLT): A shift-invariant autoencoder for calibration-free spectral unmixing of turbid media 2026-05-12T09:17:43Z The accurate recovery of constituent-level optical properties from integrating sphere measurements is a central analytical challenge in pharmaceutical analysis, food science, and biomedical diagnostics. Neural network autoencoders can extract spectrally resolved absorption and scattering coefficients for each constituent without prior knowledge, but their fully connected encoders bind learned features to absolute wavelength indices, causing accuracy loss under spectrometer calibration drift or hardware exchange. This work introduces the Bin Latent Transformer (BiLT)-Autoencoder, in which the dense encoder is replaced by a cross-attention scanner: 16 learnable probe vectors query a convolutional feature map, aggregating morphological spectral information independently of absolute wavelength position. A physics-constrained linear decoder with enforced absorption/scattering separation and a three-phase curriculum augmentation strategy complete the architecture. On a liquid phantom benchmark (intralipid and two ink absorbers; 496 samples), the model achieves $R^2 = 0.979$ and $0.975$ for $μ_a(λ)$ and $μ_s'(λ)$, respectively, on held-out test spectra, maintaining $R^2 > 0.90$ for $μ_a$ and $R^2 \approx 0.99$ for $μ_s'$ across the full tested shift range of $\pm 10$ spectral bands. The model generalises to a simulated spectrometer with a broader instrument line shape (${\approx}24$nm FWHM) without retraining, retaining $R^2 \approx 0.96$ and $0.974$ for the two channels. Attention map analysis reveals a physically interpretable two-component probe strategy: sparse anchor probes at absorption-edge wavelengths combined with a diffuse, SNR-driven ensemble at the high-transmittance long-wavelength region, which recruits additional probes dynamically under noise to provide implicit spectral averaging. 2026-05-12T09:17:43Z Martin Hohmann http://arxiv.org/abs/2601.20549v2 Multicenter Comparison of Radionuclide Calibrators and SPECT/CT Protocols for Quantitative 177Lu Imaging in Clinical Practice 2026-05-12T08:49:49Z Purpose: Following the clinical success of 177Lu-based therapies, accurate quantification of 177Lu using radionuclide calibrators (RNCs) and SPECT/CT is gaining importance as prerequisite for accurate treatment delivery and dosimetry. However, the lack of standardization can introduce inter-system variability, compromising multi-center clinical trials. This study aimed to assess the accuracy and variability of 177Lu measurements using RNCs and SPECT/CT across different systems and hospitals. Methods: A uniform cylindrical phantom and a NEMA phantom with hot spheres were prepared using traceable activities and imaged at 8 different hospitals using 13 SPECT/CT systems (9 conventional and 4 3D CZT). Acquisitions and reconstructions were performed using both site-specific and standardized protocols. The cylindrical phantom images were used to evaluate the system calibration and establish image calibration factors (ICFs), the NEMA images to evaluate effective resolution by calculating recovery coefficients (RCs). In parallel, two vials were measured to test RNC accuracy. Results: RNC measurements differed up to 11% between centers, while SPECT quantification of the cylindrical phantom differed up to 20%. While ICFs were consistent for systems of the same type, image quality varied strongly when using clinical protocols (36% difference in RCs in the largest sphere). Standardized reconstruction reduced variability in RCs for each system type (maximum 12% difference), regardless of acquisition protocol, but differences between system types persisted when standardizing acquisition and reconstruction (33% difference). Conclusion: Current 177Lu measurement practices yield significant variability in quantification and image quality. Harmonization efforts should prioritize standardized calibration and reconstruction protocols to improve multicenter reproducibility of quantitative 177Lu-SPECT/CT. 2026-01-28T12:45:04Z 30 pages, 20 figures. This version of the article has been accepted for publication, after peer review but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at EJNMMI Physics (2026) Wies Claeys Kristof Baete Laurence Beels Claire Bernard Rachele Danieli Yves D' Asseler An De Crop Michel Hesse Victor Nuttens Bruno Vanderlinden Michel Koole 10.1186/s40658-026-00877-1 http://arxiv.org/abs/2605.11637v1 Computed Tomography Reconstruction Algorithm Using Markov Random Field Model 2026-05-12T06:58:44Z X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available. 2026-05-12T06:58:44Z 17 pages, 7 figures Taiga Shimomiya Taichi Kusumi Yuichi Yokoyama Masayuki Uesugi Akihisa Takeuchi Yuki Sada Hayaru Shouno Masato Okada http://arxiv.org/abs/2605.10871v1 Attractor-Vascular Coupling Theory: Formal Grounding and Empirical Validation for AAMI-Standard Cuffless Blood Pressure Estimation from Smartphone Photoplethysmography 2026-05-11T17:24:42Z This work proposes Attractor-Vascular Coupling Theory (AVCT), a mathematical framework showing that cardiac attractor geometry encodes blood pressure (BP) information sufficient for AAMI-standard estimation, and validates the theory through a calibrated cuffless BP model using photoplethysmography (PPG). AVCT is grounded in Cardiac Stability Theory and operationalized using Takens delay embedding and attractor morphology extraction. Two theorems, one proposition, and one corollary formally justify the use of PPG attractor features for BP estimation and predict the feature-importance hierarchy. A LightGBM model trained on pulse transit time (PTT) and Cardiac Stability Index (CSI) attractor features under single-point calibration was evaluated using strict leave-one-subject-out cross-validation (LOSO-CV) on 46 subjects from BIDMC ICU (n = 9) and VitalDB surgical data (n = 37), comprising 29,684 windows. The model achieved systolic BP (SBP) mean absolute error (MAE) of 2.05 mmHg and diastolic BP (DBP) MAE of 1.67 mmHg, with correlations r = 0.990 and r = 0.991, satisfying the AAMI/IEEE SP10 requirement of MAE below 5 mmHg. Median per-subject MAE was 1.87/1.54 mmHg, and 70%/76% of subjects individually satisfied AAMI criteria. A PPG-only ablation using nine smartphone attractor features matched the ECG+PPG model within 0.05 mmHg, demonstrating that clinical-grade BP tracking is achievable using only a smartphone camera while surpassing prior generalized LOSO-CV results using fewer sensors. All four AVCT predictions were quantitatively confirmed, with 91.5% error reduction from uncalibrated to calibrated estimation (epsilon_cal = 0.915). Unlike post-hoc explainable AI methods, AVCT predicts features satisfying the architectural faithfulness criterion of the Explainable-AI Trustworthiness (EAT) framework and grounding BP estimation in nonlinear dynamical systems theory. 2026-05-11T17:24:42Z Timothy Oladunni Farouk Ganiyu Adewumi http://arxiv.org/abs/2511.20514v4 Real-time 3D Ultrasonic Needle Tracking with a Photoacoustic Beacon 2026-05-11T13:31:03Z Many minimally invasive procedures, such as core needle biopsy of focal liver lesions, nerve blocks, and fetal and vascular interventions, are typically performed under ultrasound guidance, which provides real-time, high-resolution visualisation of tissue anatomy. Accurate and efficient localisation of the needle tip relative to patient anatomy is essential for guiding the needle towards the procedure target, avoiding adverse events and reducing the need for repeat procedures. However, the 3D nature of the procedure and poor image contrast of the needle in heterogeneous tissue or at steep insertion angles often lead to confusion over the true location of the tip within the 2D guidance images, and existing methods to enhance needle visibility largely remain limited to 2D. Here, we present a novel interventional ultrasound system capable of 2D B-mode imaging and 3D needle tracking. The tip location is determined from the time-of-flight of ultrasound generated by a photoacoustic beacon embedded in the needle bevel and received by a sparse receiver array distributed around the imaging system's curvilinear ultrasound probe. The measured tracking accuracy was better than 2 mm for depths up to 140 mm in water, and approximately 2 mm on average in an ex vivo tissue phantom, with referenced positions derived from X-ray computed tomography. In a usability study involving 12 clinicians performing biopsy procedures in a ex vivo tissue phantom, the failure rate was reduced by 35%, from 15.8% to 10.3% after only a few minutes of training. These results demonstrate that the proposed system has strong potential to support a wide range of minimally invasive procedures by enabling clinicians to accurately target small anatomical structures, improving the efficiency and effectiveness of diagnostic sampling and therapeutic delivery or ablation, and reducing the risk of adverse events. 2025-11-25T17:19:23Z 25 pages, 10 figures. Accepted for publication in IOP JPhys: Photonics Christian Baker Weidong Liang Richard Colchester Peng Lei Francois Joubert Sebastien Ourselin Simeon West Adrien Desjardins Athanasios Diamantopoulos Wenfeng Xia 10.1088/2515-7647/ae6ae6