https://arxiv.org/api/y2ul50nPw3GVxu9UbV7dR2Yh22g 2026-09-10T22:28:23Z 24868 75 15 http://arxiv.org/abs/2511.09689v2 An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment 2026-08-31T02:39:31Z This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES\&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives. 2025-11-12T19:45:47Z For IEEE Transactions in Nuclear Physics, 11 pages, 14 figures Jordan D. Roberts Vibodha Bandara Kenichi Nakano Dustin Keller http://arxiv.org/abs/2605.18330v2 Compact Dual-Polarization Schottky Barrier Diode Receivers for Submillimeter Wave Remote Sensing 2026-08-30T17:29:44Z Dual-polarization heterodyne receivers operating at 325 GHz, 424 GHz, and 650 GHz at room temperature are presented. Polarimetric measurements are enabled by two orthogonal open-ended E-field probes, co-optimized and integrated with two subharmonic GaAs Schottky-barrier diode mixers. The down-converted signals (IF) are amplified using low-noise InP HEMT amplifiers integrated into the receiver module, along with IF matching networks, dc-bias boards, a shared local oscillator (LO) distribution network, and a single smooth-walled, conical, spline-horn antenna. Maximum cross-polarization isolation of 25 dB, 34 dB, and 25 dB was achieved at 315 GHz, 421 GHz, and 650 GHz, respectively. The measured double-sideband (DSB) receiver noise temperatures are 833 K, 835 K, and 1623 K at 315 GHz, 421 GHz, and 630 GHz, respectively. Stability measurements, with an integration Allan time of more than 10 s, were obtained for all receivers. Overall, the integrated dualpolarization receiver topology achieves excellent sensitivity in a highly compact package, offering an efficient and scalable solution for polarimetric applications in submillimeter-wave remote sensing 2026-05-18T12:47:50Z IEEE Transactions on Terahertz Science and Technology, 2026 Olivier Auriacombe Peter J. Sobis Vladimir Drakinskiy Anders Emrich Jan Stake 10.1109/TTHZ.2026.3729442 http://arxiv.org/abs/2608.29791v1 A high-speed anamorphic pupil-conjugate slit spectrograph for rapid, self-luminous sources 2026-08-30T13:37:33Z We present a slit imaging spectrograph whose wavelength registration is a property of the instrument rather than of the pointing of the fore-optic or the position of the source. An internal telecentric 4f relay places the system stop within the instrument while a cylindrical lens places the slit aperture at a plane where transverse position encodes source angle only (an $A = 0$ conjugate in the ABCD matrix formulation). As a result, the lateral motion of the source or the pointing of the fore-optic does not cause the spectral image illuminating the sensor to wander, thus eliminating any non-physical registration of chemical species not present in the event and the need for on-the-fly recalibration. Additionally, the use of a high-speed CMOS camera eliminates temporally averaged spectral lines and aliasing noise. We characterize wavelength calibration (He discharge lamp, quadratic fit, RMS residual 0.12 nm, verified with Ne discharge lamp, same calibration, RMS residual 0.13 nm), spectral resolution (R $\approx$ 639, FWHM 0.92 nm at the optimal slit width setting, R $\approx$ 783, FWHM 0.75 nm at the instrument profile floor), and pointing invariance (He 587.6 nm line wander 0.29 nm RMS, 1.03 nm peak-to-peak, a nearly 100x reduction relative to the same instrument with the aperture stop at the fore-optic pupil). We perform combustion spectroscopy on ignited nitrocellulose at 10 kHz, 99 $μ$s exposure time, identifying Na, K, Ca, CaOH, and Rb chemical species using the unchanged wavelength calibration transferred from the helium discharge lamp. 2026-08-30T13:37:33Z 14 pages, 6 figures, 1 table; includes supplementary information Matthew Vayner Kyle D. Gilroy http://arxiv.org/abs/2608.29648v1 Toward Ionization Cluster Size Measurements with a Compact Nanodosimeter 2026-08-30T08:19:01Z Nanodosimetry aims to provide measurable quantities related to the nanoscopic particle track structure, which determines the biological effectiveness of radiation. While simulated nanodosimetry has already demonstrated its potential for radiation treatment planning, the experimental realization of practical nanodosimetric detectors is still in its early stages. In this work, a nanodosimetric prototype operated with low-pressure gas was developed to count ionizations in a nanometer-equivalent sensitive gas volume. Its performance was evaluated experimentally with alpha beams from an Am-241 source in 1 mbar propane gas. The results support the further development of this compact nanodosimeter class, with potential applications in particle therapy, radiation protection, and space radiation dosimetry. 2026-08-30T08:19:01Z Victor Merza Aleksandr Bancer Vladimir Bashkirov Ana Belchior Beata Brzozowska Piotr Gasik Jaroslaw Grzyb Khaled Katmeh Marcin Pietrzak Antoni Ruciński Reinhard Schulte http://arxiv.org/abs/2608.23584v4 Compact nondestructive generator for microsecond-class ultrafast pulsed magnetic fields 2026-08-29T14:34:55Z The sweep rate of pulsed magnetic fields is a key factor in exploring of nonequilibrium phenomena in matter. However, the nondestructive generation of ultrafast pulsed magnetic fields is challenging because of the large time constants associated with the large inductance and capacitance of conventional pulsed magnetic field generators, as well as the residual inductance of the power devices and the system itself. We have developed a new compact pulsed magnetic field generator using commercially available state-of-the-art ultrafast power devices, enabling the generation of ultrafast pulsed magnetic fields up to approximately 1 T with a pulse duration of 3.8 $μ$s. We present the performance of the newly developed system and compare the experimentally obtained magnetic field waveforms with the results of a simple circuit simulation. In addition, we demonstrate magnetization measurements on cobalt powder and Faraday rotation measurements on CdS single crystal using the developed system. 2026-08-11T12:33:25Z Y. Ishii A. Ikeda H. Sun H. Oike Y. H. Matsuda http://arxiv.org/abs/2608.24917v2 Cusp-singularity-enhanced Coriolis effect for ultrasensitive chip-scale gyroscopes 2026-08-29T06:04:19Z Gyroscopes, as fundamental inertial sensors, are crucial for rotation measurements in consumer electronics, automotive, and aerospace industries, with the most widely used kind relying on the Coriolis effect. The chip-scale Coriolis vibratory gyroscopes (CVGs) show reduced size, weight, and cost, but remain far lower performance than traditional macroscale CVGs, as the weak intrinsic Coriolis factor sets a fundamental limit on scaling the sensitivity against the inherently louder Brownian noise in microchips compared to the macroscale ones. Here, to overcome this physical limit, for the first time, we propose and experimentally demonstrate the use of third-order singularities lying within cusp catastrophes in the phase-tracked oscillations of an on-chip CVG to facilitate a cubic-root scaling of the Coriolis-effect-induced frequency modulation. Employing this effect, we achieve a three-order-of-magnitude enhancement in the Coriolis factor, yielding a 253-fold improvement in signal-to-noise ratio and a 297-fold increase in precision. Moreover, the cusp singularity enables a previously unattainable ultrasensitive phase-modulated sublinear measurement, achieving a world-record signal-to-noise ratio performance for silicon-chip gyroscopes. These findings not only provide revolutionary advancements in gyroscope technologies, by filling the gap in observing and controlling the singularity-enhanced Coriolis effect, but also shed new light on other ultrasensitive sensing applications. 2026-08-11T04:01:45Z 27 pages, 8 figures Zhang, S. et al. Cusp-singularity-enhanced Coriolis effect for sensitive chip-scale gyroscopes. Nature 653, 700-706 (2026) Sen Zhang Dingbang Xiao Fei Wang Ran Huang Lei Yu Ning Zhou Kaixuan He Xuezhong Wu Franco Nori Hui Jing Xin Zhou 10.1038/s41586-026-10565-w http://arxiv.org/abs/2608.28906v1 Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS 2026-08-28T22:14:50Z Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics. 2026-08-28T22:14:50Z Adam Quinn Troy England Andrew Li Sharmila Mustari Nandita http://arxiv.org/abs/2606.17948v2 Optimized filtering for pulse-shape based pile-up rejection applied to $0νββ$ search with $^{100}$Mo 2026-08-28T16:41:39Z Pile-up events, arising from the partial or complete temporal overlap of distinct signals, represent a major challenge in many areas of experimental physics where rare or low-rate processes are targeted. If not properly identified, pile-up can distort reconstructed observables, degrade energy resolution, and generate backgrounds that mimic genuine events of interest. This work presents an algorithm to obtain an optimized digital filter for the discrimination of pile-up events for detectors with known signal response and stationary noise power spectral density. It is developed in the context of the search for neutrinoless double beta decay with cryogenic Li$_{2}$$^{100}$MoO$_4$ detectors like CUPID, where pile-up induced background from $^{100}$Mo $2νββ$ is expected to be the leading background contribution. For this application, the new filter discriminant reduces the pile-up induced background (at 90% efficiency) by 31%, compared to an analysis with a reference method previously presented in Eur. Phys. J. C 83(5), 373 (2023). While the discussion is grounded in cryogenic calorimetric detectors, the concepts and methods described are broadly applicable to a wide class of detector technologies and experimental contexts. 2026-06-16T14:02:25Z 11 pages, 8 figures, to be submitted to EPJ C V. Berest M. Buchynska P. Carniti A. Giuliani C. Gotti H. Khalife P. Loaiza P. de Marcillac C. Nones M. Pageot E. Olivieri G. Pessina D. V. Poda J. A. Scarpaci B. Schmidt A. S. Zolotarova http://arxiv.org/abs/2608.28356v1 Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors 2026-08-28T14:09:05Z Multi-gap Resistive Plate Chamber (MRPC) detectors offer excellent time resolution and detection efficiency, creating a strong demand for high-precision, highly scalable timing readout systems. In this work, a readout electronics system is designed for a large-area 100*100 cm MRPC detector containing 2400 high-granularity 2*2 cm pad channels. The system consists of two Front-End Boards (FEBs), a central clock distribution module, and a back-end DAQ aggregator. Each FEB is equipped with 40 32-channel PETIROC2B ASICs mounted directly behind the sensing pads. An automated S-curve calibration procedure equalizes the baseline dispersion across all 2400 channels, reducing the FWHM of the baseline voltage distribution from 50 mV to 12 mV and establishing a uniform triggering threshold. Signal-injection measurements confirm an intrinsic single-channel electronic time resolution of 33 ps RMS, alongside inter-chip and inter-board time resolutions of 43 ps RMS and 45 ps RMS, respectively. This high-granularity, high-precision timing readout system can be widely applied to Time-of-Flight systems, cosmic-ray muon imaging, as well as other fast-timing detector systems. 2026-08-28T14:09:05Z J. N. Tang W. H. Wu Y. Q. Tan W. Zhi H. J. Yang Imad Laktineh Q. P. Shen http://arxiv.org/abs/2608.28287v1 Development, Configuration and Performance Characterization of a Scalable BETA ASIC-Based Readout System for Multi-Channel SiPM Detectors 2026-08-28T12:51:37Z We present the design, configuration, and performance characterization of a scalable readout system based on the BETA application-specific integrated circuit (ASIC), developed to meet stringent requirements on noise, linearity, dynamic range, and power consumption for multi-channel silicon photomultiplier (SiPM) detectors in spaceborne instrumentation. The readout electronics consists of modular interface boards (FIBs) hosting multiple BETA ASICs and controlled by a field-programmable gate array (FPGA), which provides configuration, data acquisition, and global trigger generation. Multiple BETA FIBs were tested in a dedicated optical setup enabling simultaneous readout of a large number of channels. The system performance was evaluated using three S13552-10 SiPM arrays manufactured by Hamamatsu for the FIT detector, a scintillating-fiber tracker developed for charged cosmic-ray particle tracking and charge measurement in the HERD mission. We describe the configuration procedures and performance measurements of the readout system, including gain calibration, linearity characterization, and threshold response. In addition, we present the development of a global internal trigger logic for the identification of ionizing particles in the FIT detector. The results demonstrate the stability, scalability, and suitability of the developed BETA-based readout system for large-scale multi-channel SiPM detector applications in space experiments. 2026-08-28T12:51:37Z accepted for publication in JINST Giulio Lucchetta Keerthana Rajan Lathika Benjamin Nobre Hauptmann Philipp Azzarello Oscar Blanch Juan Boix Laia Cardiel Arturo Castaño Gallardo Albert Espinya Jennifer Maria Frieden David Gascon Daniel Gubermann Kimberly Sarah Keyser Manel Martinez Joan Mauricio Marina Orta-Terré Chiara Perrina Javier Rico Andreu Sanuy Monong Yu 10.1088/1748-0221/21/09/P09008 http://arxiv.org/abs/2608.28275v1 Full-field fluorescence computed tomography (F3CT) using a calibrated virtual cone-beam pinhole geometry 2026-08-28T12:37:25Z We present F3CT, a synchrotron-based hyperspectral full-field fluorescence computed tomography technique that avoids raster scanning by combining a pinhole aperture with an energy-resolving 2D detector. A virtual cone-beam model and two-stage calibration-reconstruction workflow enable 3D elemental mapping under full-field illumination. The method is demonstrated on biological and geological specimens, resolving silver-stain distributions in zebrafish tissue and high-energy fluorescence signatures in rock cores. Phase-contrast tomograms acquired sequentially under the same experimental geometry provide co-registered structural context. F3CT provides a high-throughput route to 3D XRF imaging and establishes a foundation for correlated structural and chemical tomography, with potential for future in-situ and operando implementations. 2026-08-28T12:37:25Z Thomas Zillhardt Yunhui Chen Alexander Rack Matthew Veale Matt Wilson Philip J. Withers Nicola Viganò http://arxiv.org/abs/2601.15998v2 Application of zone refining to the development of NaI(Tl) detectors for SABRE North 2026-08-28T11:21:06Z The SABRE North experiment is developing ultra-high radiopurity NaI(Tl) detectors to investigate dark matter. To achieve this, SABRE North utilizes the technique called zone refining for NaI purification. This work details the mathematical model developed to describe the purification process. By comparing this model to the results of the commissioning and production runs conducted prior to crystal growth, the distribution coefficients were determined for various impurities, contained in the powder at the parts-per-billion (ppb) level. Furthermore, the synthesis of data from both zone refining and normal freezing is discussed. These findings can be used to predict the SABRE North detectors background level in the energy region-of-interest for dark matter search and to optimize the production of ultra-high purity crystals through multiple purification strategies. 2026-01-22T14:18:29Z 27 pages, 15 figures, 9 tables. Minor changes in the text, few references added. Submitted to JINST C. Ananna F. B. Armani G. Cataldi D. D'Angelo G. D'Imperio M. L. De Giorgi G. Di Carlo M. Diemoz A. Ianni S. G. Khattak E. Martinenghi A. Miccoli M. Misiaszek D. Montanino V. Pettinacci L. Pietrofaccia S. Rahatlou K. Szczepaniec C. Tomei V. Toso C. Vignoli S. Zuhra L. Cid A. Mellen-Spencer S. Nisi J. Tower http://arxiv.org/abs/2608.27977v1 Compact Variational Neural Networks for Spectral Inference from a Single Nonlinear 2D Perovskite Photodetector 2026-08-28T06:46:38Z Spectroscopy conventionally separates optical frequencies before detection, imposing persistent constraints on footprint, complexity and scalability. Here we establish an alternative paradigm in which the nonlinear optoelectronic dynamics of a single two-dimensional perovskite photodetector physically encode the incident optical field and machine learning performs the inverse spectral reconstruction. Using a planar fluorinated phenethylammonium lead iodide (F-PEAI) photodetector, we exploit wavelength- and irradiance-dependent current-voltage signatures arising from the coupled effects of photocarrier generation, trapping, interfacial transport and field-dependent carrier dynamics. A compact variational encoder-decoder preserves the functional and history-dependent structure of these responses by independently projecting forward and reverse voltage sweeps onto a truncated Legendre-polynomial basis before mapping them through a probabilistic latent representation to continuous spectral parameters. Trained on fewer than 400 experimental voltage sweeps, the model generalises to excitation wavelengths excluded from training, reconstructing wavelength with $R^2=0.958$ and a mean absolute error of 8.1 nm, while recovering log-normalised irradiance with $R^2=0.987$. Voltage-resolved analysis further reveals that wavelength and irradiance are encoded differently across the nonlinear device response, with distinct bias regions carrying complementary optical information. These results establish nonlinear material and interface dynamics as a computational resource for spectroscopy and point towards hardware-algorithm co-design in which materials, interfaces and inference architectures are engineered jointly to maximise information content, enabling compact spectroscopic systems without dispersive optics or detector arrays. 2026-08-28T06:46:38Z 28 pages in main article (29 pages in the supporting information), 5 figures in the main article (11 figures in the supplementary material) Karl Jonas Riisnaes Ned Thaddeus Taylor Hoi Tung Lam Rosanna Mastria Francesco Saverio Difeo Monica Felicia Craciun Saverio Russo http://arxiv.org/abs/2608.27858v1 Extending the operating window of scanning electron microscopy through an integrated electron-optical architecture for high-temperature and near-ambient-pressure environments 2026-08-28T03:08:15Z Scanning electron microscopy (SEM) under simultaneously high-temperature, near-ambient-pressure (NAP), and reactive-gas environments requires coordinated control of vacuum isolation, electron-beam transmission, signal generation, and thermal management, constraints that have long limited the operating window of environmental scanning electron microscopy (ESEM). Here we establish an integrated electron-optical architecture that combines a multistage differential-pressure pathway, front-stage pressure transition, detector optimization, thermal management, and a gas-focusing sampling architecture into a unified ESEM platform. Pressure distribution and electron-beam transmission are quantitatively validated through computational fluid dynamics (CFD), Monte Carlo electron-gas scattering analysis, and direct beam-current measurements, while detector optimization and thermionic-electron suppression preserve stable imaging under elevated pressure and temperature. The resulting system enables stable SEM imaging at pressures up to 20,000 Pa and high-temperature imaging up to 1,400 degrees C, continuous observation of hydrated biological specimens, and synchronized SEM-QMS operando characterization using local gas sampling. These developments establish a general electron-optical framework for extending ESEM toward realistic operando environments where elevated temperature, reactive gases, structural evolution, and gas-phase chemistry can be investigated simultaneously. 2026-08-28T03:08:15Z 31 pages, 8 figures Yue Chai Honglong Zhao Xinning Tian Chao Ang Zhu-Jun Wang http://arxiv.org/abs/2608.27814v1 Migration of Belle II TOP Feature Extraction from the Zynq Processing System to PCIe40 Readout PCs 2026-08-28T01:20:51Z The Belle II Time-of-Propagation (TOP) detector is a key system for charged-particle identification (PID). Although TOP operated successfully during initial Belle II data taking, increasing luminosity and beam-induced background led to more frequent single-event upsets (SEUs) in the radiation-exposed Zynq systems-on-chip (SoCs). Resulting lockups of the embedded processing systems (PSs) interrupted data acquisition. To mitigate this limitation, waveform feature extraction, a critical task of the on-detector Zynq PS, was migrated to the off-detector PCIe40 readout PCs (ROPCs). The new architecture bypasses the PS in the event data path and performs feature extraction outside the detector radiation environment. This change removed SEU-induced PS lockups from the event data path and enabled stable operation of the TOP front-end electronics and the Belle II data-acquisition system under increased luminosity and background conditions. The typical TOP deadtime decreased from about 1% to a level consistent with zero after the final firmware patch, and stable operation was demonstrated at a Level-1 (L1) trigger rate of 30 kHz with a microchannel-plate photomultiplier-tube (MCP-PMT) hit rate of approximately 5 MHz per PMT. This paper describes the migrated architecture, its deployment and validation, and its operational and PID performance. 2026-08-28T01:20:51Z 17 pages, 9 figures Harsh Purwar Shahab Kohani Vasily Shebalin Martin Bessner Matt Andrew Thomas Browder Tommy Lam Kurtis Nishimura Sourav Patra Vladimir Savinov Marko Staric Gary Varner Satoru Yamada Keisuke Yoshihara