https://arxiv.org/api/M+OTAeAQFknWGU5CaNLWVAgVsYY2026-09-10T21:21:26Z248686015http://arxiv.org/abs/2609.01809v1Radiation Hardness of Commercially Available NUV-MT Silicon Photomultipliers2026-09-01T19:34:57ZSilicon Photomultipliers (SiPMs) based on the near-ultraviolet, metal-filled trench (NUV-MT) technology offer improved photon detection efficiency and reduced correlated noise relative to earlier designs, making them attractive for a broad range of particle- and astroparticle-physics applications. As such devices may be deployed in high-radiation environments, quantifying their performance after irradiation is essential. Commercially available Broadcom AFBR-S4N series NUV-MT SiPMs were irradiated with 1 MeV neutrons to fluences between 2x10^{9} and 1.1x10^{10} n_{eq}/cm^2 at the TANDEM accelerator facility of NCSR "Demokritos" in Athens, and characterised before and after irradiation and over successive thermal-annealing stages. Irradiation increased the dark noise by up to three orders of magnitude and degraded the single-photon resolution by up to a factor of ten, with resolution lost entirely at the highest fluence, while no shift in breakdown voltage was observed. Thermal annealing partially recovered the performance, reducing the dark noise by up to a factor of two and restoring the single-photon resolution.2026-09-01T19:34:57Z11 pages, 8 figuresT. AvgitasM. AxiotisZ. BalmforthI. ManthosK. NikolopoulosE. TaimpiriC. ToukmenidisA. Ziagkovahttp://arxiv.org/abs/2609.01703v1Multidimensional Double Refraction Microscopy2026-09-01T17:27:41ZMultidimensional optical microscopy - extracting 3D location, orientation, and spectral information from nanoscale emitters - is key to modern nanoscience. However, this multidimensional capability requires complex instrumental setups, demanding exceptional stability and specialized expertise in optics. Here, we overcome these barriers by introducing Double Refraction Microscopy (DRM), a passive imaging method providing a straightforward pathway to multidimensional super-resolution imaging. Based on bifocal imaging via a birefringent microscope slide, DRM splits nanoprobe light into a characteristic double image encoding 3D location, orientation, and spectral signature, while requiring zero hardware modifications to standard wide-field microscopes. To showcase its robustness, we implement DRM across three distinct slides of varying materials and thicknesses, calibrating 3D localization with 450-nm nanoparticles and demonstrating high orientation sensitivity using polarization-controlled emitters. Furthermore, we confirm spectral readout using a pinhole array acting as a grid of point emitters back-illuminated at various wavelengths to generate distinct spectral signatures. Finally, we showcase practical utility by performing a two-colour 3D localization measurement within a $10\,μ\text{m}$ gap, utilizing the single optical pathway of a standard epi-fluorescence microscope. Ultimately, DRM provides the missing optical hardware simplicity to complement established computational tools, promising to transfer advanced super-resolution capabilities from specialized facilities to every laboratory bench.2026-09-01T17:27:41Z25 pages manuscript (double-spaced, single-column), 6 figures, plus 3 pages Supplementary InformationJörg KönigInstitute of Micro- and Nanotechnologies, Technische Universität Ilmenau, GermanyInstitute of Thermodynamics and Fluid Mechanics, Technische Universität Ilmenau, GermanyChristian CierpkaInstitute of Micro- and Nanotechnologies, Technische Universität Ilmenau, GermanyInstitute of Thermodynamics and Fluid Mechanics, Technische Universität Ilmenau, Germanyhttp://arxiv.org/abs/2609.01522v1Fabrication and characterization of lithium-diffused inverted coaxial point-contact HPGe detectors2026-09-01T16:52:36ZHigh-purity germanium (HPGe) detectors with low capacitance, low electronic noise, and stable high-voltage operation are important for high-resolution gamma-ray spectroscopy and rare-event searches. We report the fabrication and characterization of two compact p-type inverted coaxial point-contact (ICPC) HPGe detectors, AK01 and AK02, produced from crystals grown at the University of South Dakota. Both devices use lithium-diffused $n^{+}$ outer contacts together with amorphous-Ge/Al point-contact electrodes. The principal advance is the implementation of this hybrid contact process on two independently fabricated USD-grown ICPC prototypes and the demonstration of stable electrical and spectroscopic operation. Both detectors exhibited picoampere-level leakage currents, operational depletion-voltage ranges of approximately 200--250~V (AK01) and 240--260~V (AK02), and estimated effective plateau capacitances of approximately 0.84 and 0.87~pF, respectively. Measurements with a $^{137}$Cs source yielded archived full-energy-peak FWHM values of 1.71 and 1.62~keV near 662~keV for AK01 and AK02, while AK02 yielded 1.04~keV FWHM at 59.5~keV with $^{241}$Am. Electric-field calculations reproduce the expected ICPC field configuration for the measured detector geometry. A Geant4 model of AK02 is used as a qualitative response study; its 0.8-mm Li-diffused inactive layer is an illustrative model assumption rather than a measured thickness, and its Gaussian broadening is constrained by the experimental resolution. The work therefore establishes the fabrication and operation of compact lithium-diffused ICPC prototypes while identifying quantitative inactive-layer characterization as an important next step.2026-09-01T16:52:36Z19 pages, 14 figures, and 1 tableAnupama KarkiKunming DongDongming Meihttp://arxiv.org/abs/2005.06003v2Dissipative coupling, dispersive coupling and their combination in the cavity-less opto-mechanical systems2026-09-01T15:23:23ZThe approach of variational measurement is applied to the cavity-less dissipative coupling (when test mass displacement is changing transmittance of a single mirror). The result obtained is compared to the cavity-less dispersive coupling (when the mass of displaced single mirror is changing the phase in reflected wave). These types of coupling are compared for ponderomotive squeezing. In addition, the cavity-less variant of combined dissipative and dispersive coupling is explored. It is established that combined coupling results in a stable optical rigidity even in case of a single pump. Finally, it is confirmed that variational measurement can be applied to combined coupling.2020-05-12T18:45:57Z9 pages, 4 figuresPhys. Rev. A 102, 023513 (2020)Alexandr KarpenkoFaculty of Physics, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, RussiaSergey P. VyatchaninFaculty of Physics, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, RussiaQuantum Technology Centre, M.V. Lomonosov Moscow State University, Leninskie Gory, Moscow, Russia10.1103/PhysRevA.102.023513http://arxiv.org/abs/2609.01336v1Validating a BDT-based Electron-Positron Identification Algorithm at CLAS12 with Experimental Data2026-09-01T14:49:00ZThis article presents a machine-learning, particle-identification algorithm for electrons and positrons in the CLAS12 experiment. The main objective was to minimize charged-pion contamination for both experimental and simulated data. We developed, evaluated and validated two BDT models with different input features, both trained on simulated samples, and conducted rigorous validation using both simulated and experimental data to ensure reliability. Our results show the effectiveness of the applied models in mitigating background contamination. By retaining more than 90\% of leptons in the simulated samples, the charged-pion background is largely reduced. Performance was evaluated on experimental data, providing a framework to validate such approaches at CLAS12 and future electron-beam facilities.2026-09-01T14:49:00ZMariana Tenorio PitaPierre ChatagnonRichard Tysonhttp://arxiv.org/abs/2606.25817v2On-Sky Single-photon Time resolution of 35 ps with White Rabbit synchronization: towards the measurement of the size of a White Dwarf star2026-09-01T13:29:16ZThe IC4Stars (Intensity Correlation for Stars) project aims to measure the diameter of the white dwarf star Sirius B, using Intensity Interferometry. In this work we present our latest efforts and the milestones achieved in the last year. We report laboratory characterization of the single-photon detectors, TDC and synchronization electronics. We describe an observation campaign where we demonstrated on-sky time resolution below 35 ps RMS, synchronizing two TDCs using the White Rabbit protocol and a 30 m telecom fiber. We developed the data acquisition of the raw time tags, and an algorithm to compute the second-order correlation function.2026-06-24T13:32:15ZF. Izraelevitch-PatitucciS. TolilaI. EllafiJ. -P. RivetM. HugbartG. LabeyrieO. LaiA. ZmijaW. GuerinR. Kaiserhttp://arxiv.org/abs/2609.01124v1Helium-Gas-Cooled Cryogenic Current Comparator Integrated with a Quantum Resistance Standard2026-09-01T12:02:07ZWe report a cryogen-free cryogenic current comparator (CCC) system for precision resistance measurements. A helium-gas chamber was developed and installed on the 4 K stage of a cryogen-free dilution refrigerator equipped with a pulse-tube cryocooler. The CCC probe was housed in this chamber and was cooled through helium gas serving as a heat exchange medium. The metrological performance of this helium-gas-cooled CCC was evaluated through precision resistance-ratio measurements and found to be comparable to that obtained under liquid-helium cooling. A quantum Hall resistance (QHR) device was also integrated into the same refrigerator, enabling QHR/100~$Ω$ resistance-ratio measurements. The type-A uncertainty reached the 1~n$Ω$/$Ω$ level within an averaging time of 100~s, and the resulting resistance-ratio measurements agreed well with conventional liquid-helium-based measurements at the level of a few n$Ω$/$Ω$. The system provides this level of measurement performance while consuming less than 1~L of helium gas per thermal cycle.2026-09-01T12:02:07Z8 pages, 6 figures, supplementary material includedYuma OkazakiTakehiko OeNobu-Hisa Kanekohttp://arxiv.org/abs/2509.21246v2Peak separation methods for inverse photoelectron spectra: Comparing second derivative, curve fitting, and deconvolution analyses2026-09-01T09:10:18ZInverse photoelectron spectroscopy (IPES) is a powerful technique for probing the unoccupied electronic states of materials. It can be regarded as the inversion process of photoelectron spectroscopy (PES), which examines the occupied states. Recently developed low-energy inverse photoelectron spectroscopy (LEIPS) can significantly advance the study of unoccupied states, owing to minimal sample damage and suppressed dark counts compared to conventional IPES. However, the instrumental resolution remains at 0.2 eV, which is one order of magnitude lower than that of PES. Spectral broadening caused by the low instrumental resolution often results in overlapping peaks. Peak separation is therefore crucial in the analysis of LEIPS spectra. In this study, we compared three peak separation methods-second derivative, curve fitting, and deconvolution. These methods were applied to modeled and experimental LEIPS spectra of the lowest unoccupied molecular orbital-derived band of pentacene, which consists of two splitting peaks due to the two inequivalent molecules in the unit cell. We systematically and quantitatively evaluated the performance of each method in terms of analysis parameters and discussed its robustness to noise as well as its peak separation capabilities as a function of peak energy spacing and intensity ratio. This work offers a practical framework for peak separation in LEIPS, with extensions to PES and a wide range of spectroscopies.2025-09-25T14:39:26Z16 pages, 7 figures. Published in Review of Scientific InstrumentsRev. Sci. Instrum. 97, 023906 (2026)Ryotaro NakazawaHaruki SatoHiroyuki Yoshida10.1063/5.0303140http://arxiv.org/abs/2503.19983v5A Linear Collider Vision for the Future of Particle Physics2026-08-31T17:57:19ZIn this paper we review the physics opportunities at linear $e^+e^-$ colliders with a special focus on high centre-of-mass energies and beam polarisation, take a fresh look at the various accelerator technologies available or under development and, for the first time, discuss how a facility first equipped with a technology mature today could be upgraded with technologies of tomorrow to reach much higher energies and/or luminosities. In addition, we will discuss detectors and alternative collider modes, as well as opportunities for beyond-collider experiments and R\&D facilities as part of a linear collider facility (LCF). The material of this paper will support all plans for $e^+e^-$ linear colliders and additional opportunities they offer, independently of technology choice or proposed site, as well as R\&D for advanced accelerator technologies. This joint perspective on the physics goals, early technologies and upgrade strategies has been developed by the LCVision team based on an initial discussion at LCWS2024 in Tokyo and a follow-up at the LCVision Community Event at CERN in January 2025. It heavily builds on decades of achievements of the global linear collider community, in particular in the context of CLIC and ILC.2025-03-25T18:09:46ZCommunity document for EPPSU, major updates of several sections, in particular the global interpretation section v5: fixed mistake in H->inv projections in Tab 6 and Tab 11, added section 2.4 on expected event numbersH. AbramowiczE. AdliF. AlharthiM. Almanza-SotoM. M. AltakachW. AltmannshoferS. Ampudia CastelazoD. Angal-KalininJ. A. AnguianoR. B. ApplebyO. ApsimonA. ArbeyF. ArcoO. ArqueroA. AryshevS. AsaiD. AttieJ. L. Avila-JimenezH. BaerJ. A. BaggerY. BaiI. R. BaileyC. BalazsP. BambadeT. BarklowJ. BaudotP. BechtleT. BehnkeA. B. BelleriveS. BelomestnykhY. BenhammouJ. Berenguer-AntequeraM. BergerM. BerggrenM. BertucciM. BesanconD. BettP. -C. BhatT. BiekoetterS. BilanishviliB. BilkiB. BilkiJ. Bjorklund SvenssonV. M. BjellandC. BlanchB. BliewertM. BoehlerS. BoogertM. BoronatV. BoudryD. BourilkovI. BozovicJ. BraathenJ. E. BrauC. BreuningJ. -C. BrientI. BrockB. BrudnowskiK. BuesserE. BulyakP. N. BurrowsG. BurtO. CakirA. CaldwellA. C. CanbayF. G. CelibertoE. CenniI. ChaikovskaR. ChehabG. ChenJ. B. B. ChenT. ChikamatsuV. CilentoP. ColasM. ComanL. CornerF. CornetF. Cornet-GomezF. CorriveauR. CorsiniJ. CvachR. D'ArcyC. DamerellA. DasS. DasuJ. de BlasE. Del CoreM. DemarteauH. DenizliR. DermisekA. DharS. DittmaierF. DjurabekovaE. M. DoneganiA. DoyleP. DrobniakT. A. du PreeB. DudarH. Duran YildizG. DurieuxJ. DuttaS. EasoG. EckerlinU. EinhausC. EmmaE. EsareyD. EsperanteD. EspriuL. R EvansJ. FarmerA. Faus GolfeM. FernandezJ. C. Fernandez-OrtegaM. FormelaA. FormentiL. J. ForresterB. FosterN. FourchesM. C. FouzA. FreitasC. D. FuK. FujiiJ. FujimotoB. FuksJ. FusterN. Fuster-MartinezM. GabelmannF. GaedeM. GallettiE. GalloS. GanjourM. V. GarzelliR. L. GengS. GessnerI. D. GialamasB. GimenoJ. GoldsteinM. GoncerzA. J. GonsalvesF. J. GonzalezD. Gonzalez-IglesiasS. GoriJ. GramesP. GrannisL. GrayG. GrenierH. GulerH. E. HaberK. HamaguchiN. HamannO. HartbrichN. M. HartmanG. HuetsiS. HeinemeyerG. HeinrichC. HenselK. HidakaS. HiroseA. H. HoangM. J. HoganW. HollikY. HoriiR. HosokawaS. HuangD. HyndsM. I. IdzikS. IguroY. IiyamaK. IkematsuA. IrlesA. IshikawaM. IshinoI. P. IvanovY. IwashitaM. JacewiczR. JaramilloD. JeansC. JingR. M JonesW. KaabiM. KaganJ. KalinowskiD. K KalvikJ. KaminskiS. KanemuraK. KannikeA. KaramY. KatoK. KawagoeD. KaeferL. KennedyJ. KerstenS. A. KhanV. A. KhozeW. KilianJ. KlamkaP. KluitK. KongP. KoppenburgA. KorsunA. V. KotwalS. KramlK. KruegerK. KuboT. KuboM. KucharczykS. KudayA. KumarN. KumarM. KurataY. KuriharaM. KurikiJ. KvasnickaK. KyoyaI. LaktinehA. LatinaF. LeDiberderA. LevyM. LiepeC. A. LindstroemJ. ListB. ListM. LitosV. N. LitvinenkoA. Lopez-VirtoX. LuT. LuoM. LupbergerB. MadisonT. MadlenerJ. MaedaF. MahmoudiE. MainaN. MajernikR. Margraf-O'NealT. W. MarkiewiczP. Martin-LunaA. MartensV. J. MartinL. MarzolaV. I. MaslovK. T. MatchevS. MatsumotoK. MawatariJ. P. MarquezM. M. MuehlleitnerA. McIlvennyP. A. McIntoshK. MekalaD. MeliniF. MeloniA. MenandezS. MichizonoK. MimasuV. MirallesW. MitaroffV. A. MitsouL. MonacoG. Moortgat-PickM. Moreno-LlcerT. MoriJ. M. MoronS. MortonD. MoyaM. MulderP. MunbodhH. MurayamaE. MusumeciV. V. MytrochenkoN. NagataE. NagyT. NakadaJ. NakajimaK. NakamuraE. A. NanniE. NardiS. NaritaM. T. Nunez Pardo de VeraM. NojiriD. NtounisA. OdyO. M. OgreidT. OhlY. OkadaC. OleariM. OlvegardM. OmetT. OmoriY. OnelH. OnoW. OotaniC. OreroJ. OsborneK. OsterbergJ. OsterhoffM. OuchemhouQ. OuyangS. Pagan GrisoR. PaparellaS. C. ParkJ. PataJ. R. PattersonR. PoeschlF. PenaL. K Pedraza-MotavitaM. E. PeskinF. PilatP. PiotS. PlaetzerI. PolakW. PorodK. PotamianosC. T. PotterP. PouloseJ. G. PowerD. ProtopopescuH. R. QiJ. Rabara BaileyA. RacioppiM. RaidalJ. P. RalstonA. RastogiL. ReichenbachL. ReichweinL. ReinaJ. ReuterF. RichardS. RiemannR. A. RimmerT. RobensA. RobsonG. RodrigoC. S. RoganJ. RojoM. Q. RuanS. RudrabhatlaA. Ruiz JimenoT. SaekiH. SakaiY. SakakiF. SalvatoreT. SanukiS. SasikumarT SchoernerA. ScheinkerC. B. SchroederS. SchroederI. SchulthessM. SchumacherA. SchwartzmanY. SeiyaA. SenolH. SertD. SertoreA. SeryiT. ShidaraK. SjobakI. SmiljanicS. SpannagelM. SpiraM. StanitzkiS. StapnesD. StoreyJ. StrubeS. SuA. SubbaA. SubbaT. SueharaH. SugawaraK. SugizakiZ. SunR. SzafronT. TakahashiT. TakeshitaT. TauchiG. TaylorN. TerunumaD. TerzaniT. TeubnerJ. TianJ. TimmermansM. TitovR. Tomas GarciaT. TongJ. M. TorndalM. TrautweinA. TricoliK. TsumuraB. TuchmingD. TucklerI. Turk CakirM. TytgatA. UklejaC. ValleeR. Van KootenJ. van TilborgA. VauthM. VellascoC. VernieriL. VerraM. Vicente Barreto PintoI. VidakovicH. VideauE. ViklundI. VilaM. VillaplanaM. VosN. VukasinovicN. WalkerK. Wandall-ChristensenY. WangB. F. L. WardZ. WasT. WatanabeN. K. WatsonG. WeigleinJ. D. WellsH. WennloefM. WenskatS. WesthoffJ. W. WetzelA. P. WhiteP. H. WilliamsM. WilliamsG. W. WilsonM. WingM. WinterA. WinterT. WojtonJ. C. WoodW. WuenschX. XiaK. YagyuK. YamamotoY. YamamotoH. YamamotoA. YamamotoS. YamashitaM. YamauchiK. YokoyaM. YoshiokaJ. ZalesakA. F. ZarneckiK. ZembaczynskiD. ZerwasJ. ZhangY. ZhangW. ZhangY. -M. ZhongM. ZielinskiM. Zobovhttp://arxiv.org/abs/2608.31135v1FPGA-based TDC for SiPM Timing and Amplitude Measurements2026-08-31T17:43:25ZSilicon photomultipliers (SiPMs) are widely used in photon-counting applications, such as positron emission tomography or particle physics, where precise timestamps and photoelectron number information are both required. In this work, a Time-to-Digital Converter with amplitude measurement capabilities was designed using an Artix-7 XC7A35T FPGA. For amplitude measurements, the internal xADC of the FPGA was chosen over other alternatives for simplicity. This design has two channels and can operate in timestamp-only mode or timestamp + amplitude mode. In turn, channels can be operated independently or in coincidence. The Integral Non-Linearity and Differential Non-Linearity of the design were studied, along with its time resolution, which is $(19 \pm 1)$ ps. Using a CAEN DT5810 pulse emulator, the design was tested further in timing-only mode, timing + amplitude mode and in coincidence mode to showcase its performance when using Poisson distributed SiPM-like pulses of various amplitudes.2026-08-31T17:43:25ZLucas FinazziFelipe SorianoLeandro GagliardiFederico Golmarhttp://arxiv.org/abs/2608.31123v1Development and characterization of a wingless ICPC HPGe detector with thin amorphous-Ge contacts2026-08-31T17:35:55ZHigh-purity germanium (HPGe) detectors with thin amorphous-germanium (a-Ge) contacts can provide bipolar charge blocking and surface passivation while minimizing contact-related inactive thickness. We report the fabrication and characterization of a p-type inverted coaxial point-contact (ICPC) HPGe detector using thin a-Ge contacts in a wingless geometry that avoids the protective wing structure used in our previous prototype. The detector was fabricated from a USD-grown, zone-refined HPGe crystal and has a mass of 20.0~g. At 77~K, it exhibited picoampere-scale leakage current and an operational depletion voltage of approximately 440~V. Gamma-ray spectroscopy yielded energy resolutions of 1.75~keV FWHM at 59.5~keV and 3.19~keV FWHM at 662~keV. The calibrated charge-injection method gave an absolute capacitance of 0.496~pF, with an estimated method-level relative uncertainty of 6--8\%, consistent with the 0.488~pF value obtained from electrostatic modeling with \texttt{SolidStateDetectors.jl}. With a $^{241}$Am source positioned inside the detector bore, the detector showed a source-correlated excess current and a broad degraded-alpha continuum centered near 3558~keV, demonstrating sensitivity to near-surface interactions. Because the source encapsulation, intervening materials, and near-surface charge-collection response were not independently characterized, the continuum is not used to infer a unique dead-layer thickness or energy-loss mechanism. The principal result is successful fabrication and stable sub-pF operation of a 20-g wingless thin-contact ICPC prototype.2026-08-31T17:35:55Z17 pages, 7 figures, and 3 tableS. A. PanamaldeniyaK. M. DongD. M. Meihttp://arxiv.org/abs/2608.30815v1A general framework for disturbance compensation in airborne and seaborne gravimetry supported by machine learning2026-08-31T13:59:57ZHigh-accuracy measurement systems operating in complex operational environments, such as airborne and seaborne gravimetry, are severely affected by interacting external influences (disturbances) including temperature variations, inertial accelerations, and platform rotations. This work aims to develop and prove a general method for compensating such disturbances beyond the limits of conventional approaches. We present a general framework based on three pillars: a multi-sensor system, supervised machine learning, and a dedicated laboratory -training platform-. This measurement technique was investigated through two experimental case studies relevant to airborne and seaborne gravimetry: (i) temperature and thermal-gradient rejection in a high-sensitivity tri-axial accelerometer, and (ii) pitch and roll rejection for vertical acceleration estimation. The experiments highlighted that, although the general framework provides a useful guideline, its application to airborne and seaborne gravimetry is challenging and not straightforward, requiring the development of dedicated and innovative experimental solutions. This difficulty arises from the specific nature of the measurand-gravity-which cannot be easily varied under controlled conditions. In this work, we present a dedicated approach to addressing these challenges.2026-08-31T13:59:57ZPublished 25 August 2026 Copyright 2026 The Author(s). Published by IOP Publishing Ltd Measurement Science and Technology, Volume 37, Number 34 Citation Lorenzo Iafolla et al 2026 Meas. Sci. Technol. 37 346002Lorenzo IafollaMassimo ChiappiniRoberto CarluccioStefano ChiappiniEmiliano FiorenzaCarlo LefevrePasqualino LoffredoMarco LucenteFrancesco Santoli10.1088/1361-6501/ae9789http://arxiv.org/abs/2608.30495v1In-situ suppression of surface radon emanation using an HDPE barrier at the Stawell Underground Physics Laboratory (SUPL)2026-08-31T09:25:49ZRadon-induced backgrounds remain a limiting factor in low-background experiments conducted in underground laboratories. The enclosed nature of these laboratories can result in elevated radon levels, with emanation from the surrounding rock representing the primary source of radon. In this work, we present an in-situ study of radon emanation from the floor of the main experimental hall at the Stawell Underground Physics Laboratory (SUPL) and investigate the use of a high-density polyethylene (HDPE) barrier to suppress emanation. Surface emanation was measured using an AIRTHINGS Corentium Pro passive detector before and after installation of the barrier. The equilibrium radon concentration within the surface emanation setup was reduced from 5840 $\pm$ 50 Bq m $^{-3}$ to 259 $\pm$ 3 Bq m$^{-3}$, corresponding to a suppression of $\sim$96%. These results demonstrate the potential to retrofit radon barriers to suppress surface emanation under realistic underground conditions, supporting their use in planned low-background infrastructure at SUPL and future applications at other underground laboratories.2026-08-31T09:25:49ZR. R. Marcelo GregorioK. Mintern-LaneS. RushbrookA. G. McLeanL. J. BignellJ. M. C. BrownG. J. LaneN. J. C. Spoonerhttp://arxiv.org/abs/2504.04727v2Regression Model for Measurement of Wound Dimensions by Webcam Scanners and Time-of-Flight Sensors2026-08-31T07:58:33ZOne use of image processing is for medical equipment such as wound identification. This technology is carried out non-invasively by taking images so as to avoid direct touch with the wound thereby reducing the possibility of infection. The images obtained using the RGB camera will be used for color segmentation which will measure the wound dimensions. However, the image data is in the form of a raster, the distance will affect the pixel size. Therefore, it is necessary to consider the distance of the camera measurement to the object. The time-of-flight (ToF) method with a lidar sensor is used to calculate the distance of the camera to the object. It is necessary to calculate the ratio of the distance to the number of pixels obtained so that the value is always consistent. This study analyzed the use of appropriate ratios and regression systems on a webcam and a lidar sensor for measuring wound dimensions. The results of the study show that there is a regression model with a second-order polynomial relationship for the distance and number of pixels obtained consistently with an error value of less than 5% which shows very good results2025-04-07T04:42:20ZThis paper has been withdrawn by the authors to allow for a major revision of the data. Substantial corrections are required before the findings can be considered reliable. We plan to update the manuscript once the re-evaluation is completeS. B. WibowoA. A. NugrohoL. AwaludinL. Hidayathttp://arxiv.org/abs/2608.27765v2Frequency Synchronization Circuit Model for Analog Vector-Matrix Multiplication in the Frequency Domain2026-08-31T02:42:19ZThis work introduces a frequency synchronization circuit model for analog vector-matrix multiplication in the frequency domain. The frequency synchronization is implemented by coupling oscillators through all-to-all connections. Each oscillator is implemented using complementary cross-coupled transconductance pairs and RC high-pass filters. In this work, the frequency synchronization is achieved not only using oscillators alone but also through a configuration in which oscillators and resonator models (i.e., MEMS/NEMS resonators) are combined. While addressing the frequency synchronization of all the coupled oscillators, a partial synchronization is also discussed by controlling the coupling strength of a selected subset of oscillators. This frequency synchronization analysis focuses on the small-signal analysis using analog circuit and resonator models, thereby enabling an understanding of the synchronized frequency defined by the parameters of the analog circuit and resonator models.2026-08-27T22:57:16Z26 pages, 14 figures, technical reportsTaeju LeeScott T. HabermehlTimothy W. CapliceMichael L. RoukesPhilip X. -L. FengKenneth L. Shepard