https://arxiv.org/api/imxDFhTq3TElOYR71KfUIy4HsOo 2026-03-28T14:20:19Z 24068 45 15 http://arxiv.org/abs/2603.05558v2 Environmental Measurements in the Sedrun Access Shaft to the Gotthard Base Tunnel -- a Promising Site for a Long-Baseline Atom Interferometer 2026-03-21T10:33:19Z Atom interferometer (AI) experiments offer interesting prospects for searches for the interactions of ultralight bosonic dark matter with Standard Model particles as well as detection of gravitational waves in a frequency band inaccessible to experiments that are operating or under construction. Ideal locations for the next generation of such experiments are provided by long vertical shafts, such as that providing access to the Gotthard base railway tunnel from the Sedrun locality in the Canton Grisons of Switzerland. We present the results of an exploratory environmental measurement campaign at this location to evaluate the ground motion activity and the background electromagnetic field quality. We find that the backgrounds due to both ground motion and electromagnetic fields, including those due to passing trains, are low enough for successful operation of a 800-m AI experiment. 2026-03-05T09:31:19Z V2: affiliation update M. Guinchard O. Buchmüller S. Calatroni J. Ellis S. Hoell M. Jaussi L. Lombriser M. Pentella D. Thuliez D. Valuch http://arxiv.org/abs/2603.23549v1 Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network 2026-03-20T22:21:04Z Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural xenon target allows it to search for the neutrinoless double-beta decay ($0νββ$) process, which would violate lepton number conservation and indicate that neutrinos are Majorana particles. However, such $0νββ$ searches have been limited by gamma-ray backgrounds originating from the detector materials. In this work, we designed an augmented convolutional neural network (A-CNN) model to extract additional event-topology information from detector data. Using simulation and calibration data from XENONnT, a leading LXe TPC experiment, our model achieved over 60% background rejection while maintaining 90% signal acceptance. This rejection power improves XENONnT's projected sensitivity of the $^{136}$Xe $0νββ$ search by about 40%. The implementation of A-CNN in the data analysis of future liquid xenon observatories, such as XLZD, will further enhance their sensitivities for $0νββ$ with $^{136}$Xe. 2026-03-20T22:21:04Z E. Aprile J. Aalbers K. Abe M. Adrover S. Ahmed Maouloud L. Althueser B. Andrieu E. Angelino D. Antón Martin S. R. Armbruster F. Arneodo L. Baudis M. Bazyk L. Bellagamba R. Biondi A. Bismark K. Boese R. M. Braun G. Bruni G. Bruno R. Budnik C. Cai C. Capelli J. M. R. Cardoso A. P. Cimental Chávez A. P. Colijn J. Conrad J. J. Cuenca-García V. D'Andrea L. C. Daniel Garcia M. P. Decowski A. Deisting C. Di Donato P. Di Gangi S. Diglio K. Eitel S. el Morabit R. Elleboro A. Elykov A. D. Ferella C. Ferrari H. Fischer T. Flehmke M. Flierman R. Frankel D. Fuchs W. Fulgione C. Fuselli R. Gaior F. Gao R. Giacomobono F. Girard R. Glade-Beucke L. Grandi J. Grigat H. Guan M. Guida P. Gyorgy R. Hammann A. Higuera C. Hils L. Hoetzsch N. F. Hood M. Iacovacci Y. Itow J. Jakob F. Joerg Y. Kaminaga M. Kara S. Kazama P. Kharbanda M. Kobayashi D. Koke K. Kooshkjalali A. Kopec H. Landsman R. F. Lang L. Levinson A. Li I. Li S. Li S. Liang Z. Liang Y. -T. Lin S. Lindemann M. Lindner K. Liu M. Liu F. Lombardi J. A. M. Lopes G. M. Lucchetti T. Luce Y. Ma C. Macolino J. Mahlstedt F. Marignetti T. Marrodán Undagoitia K. Martens J. Masbou S. Mastroianni V. Mazza A. Melchiorre J. Merz M. Messina A. Michel K. Miuchi A. Molinario S. Moriyama K. Morå M. Murra J. Müller K. Ni C. T. Oba Ishikawa U. Oberlack S. Ouahada B. Paetsch Y. Pan Q. Pellegrini R. Peres J. Pienaar M. Pierre G. Plante T. R. Pollmann A. Prajapati L. Principe J. Qin D. Ramírez García A. Ravindran A. Razeto R. Singh L. Sanchez J. M. F. dos Santos I. Sarnoff G. Sartorelli J. Schreiner P. Schulte H. Schulze Eißing M. Schumann L. Scotto Lavina M. Selvi F. Semeria F. N. Semler P. Shagin S. Shi H. Simgen Z. Song A. Stevens C. Szyszka A. Takeda Y. Takeuchi P. -L. Tan D. Thers G. Trinchero C. D. Tunnell K. Valerius S. Vecchi S. Vetter G. Volta C. Weinheimer M. Weiss D. Wenz C. Wittweg V. H. S. Wu Y. Xing D. Xu Z. Xu M. Yamashita J. Yang L. Yang J. Ye M. Yoshida L. Yuan G. Zavattini Y. Zhao M. Zhong T. Zhu http://arxiv.org/abs/2504.15307v4 Modeling frequency instability in high-quality resonant experiments 2026-03-20T19:26:20Z Modern resonant sensing tools can achieve increasingly high quality factors, which correspond to extremely narrow linewidths. In such systems, time-variation of the resonator's natural frequency can potentially impact its ability to accumulate power and its resulting sensitivity. One such example is the Dark SRF experiment, which utilizes superconducting radio frequency (SRF) cavities with quality factors of $Q\sim10^{10}$. Microscopic deformations of the cavity lead to stochastic jittering of its resonant frequency with amplitude 20 times its linewidth. Naively, one may expect this to lead to a large suppression in accumulated power. In this work, we study in detail the effects of frequency instability on high-quality resonant systems, utilizing the Dark SRF experiment as a case study. We show that the timescale of jittering is crucial to determining its effect on power accumulation. Namely, when the resonant frequency varies sufficiently quickly, the system accumulates power as if there were no jittering at all. This implies that the sensitivity of a jittering resonator is comparable to that of a stable resonator. In the case of Dark SRF, we find that jittering only induces a $\sim 10\%$ loss in power. Our results allow the dark-photon exclusion bound from Dark SRF's pathfinder run to be refined, leading to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio which is four orders of magnitude larger). This result represents the world-leading constraint on dark photons over a wide range of masses below $6\,\rm μeV$ and translates to the best laboratory-based limits on the photon mass $m_γ<2.9\times 10^{-48}\,\rm g$. 2025-04-18T19:22:27Z 21 pages, 8 figures; v4 includes updates from review process Phys. Rev. D 113, 052008 (2026) Hao-Ran Cui Saarik Kalia Zhen Liu 10.1103/w43x-xwh9 http://arxiv.org/abs/2603.14167v2 Beam Test of a SiPM-on-Tile ZDC Prototype with 5.3 GeV Positrons at Jefferson Laboratory 2026-03-20T17:04:07Z We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron-Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned for the final detector and includes 370 instrumented channels, corresponding to O(10%) of the full ZDC. The detector was tested using a 5.3 GeV positron beam at Jefferson Laboratory. We measure the energy response, shower shape, and spatial reconstruction performance of the detector and compare these results with simulation. These studies provide key input for the optimization of the final ePIC ZDC design. 2026-03-15T01:01:16Z Sean Preins Weibin Zhang Ryan Tsiao Mia Macias Brice Saunders Love Preet Miguel Arratia http://arxiv.org/abs/2603.20080v1 New method for clustering thresholds determination in Microstrip Silicon Detector 2026-03-20T16:03:21Z The Microstrip Silicon Detector (MSD) is one of the subsystems of the FragmentatiOn Of Target (FOOT) experiment whose goal is to measure double differential nuclear fragmentation cross sections for applications in particle therapy and radioprotection in space. The MSD, composed of six 150 $μ$m-thick silicon sensors arranged in three X-Y measuring planes, is part of the FOOT experiment tracking region. In this work, we propose a new method to set the MSD thresholds for the clustering algorithm independently of the other detectors of the experiment. The obtained values can be used as reference values from which to perform a threshold scan in order to evaluate the single-ion detection efficiency of each MSD sensor and to orient the clustering analysis using tracking information.} 2026-03-20T16:03:21Z Accepted for publication in the Journal of Instrumentation (JINST) S. Mazzolani for The FOOT Collaboration I. Mattei for The FOOT Collaboration L. Servoli for The FOOT Collaboration http://arxiv.org/abs/2503.22364v2 High-resolution cryoEM structure determination of soluble proteins after soft-landing electrospray ion beam deposition 2026-03-20T15:43:44Z Electrospray ion beam deposition (ESIBD) is the intact, chemically selective deposition of molecular ions on surfaces in vacuum. Here, we present a general method and dedicated instrumentation for ESIBD-based cryoEM sample preparation of soluble proteins. Precise control over deposition energy, sample environment, and reproducible growth of thin, homogeneous, vitreous ice films embedding the deposited proteins results in samples suitable for high-resolution cryoEM structure determination. Applied to several protein complexes, $β$-Galactosidase, GDH, RuBisCo, GroEL, the workflow yields near-atomic resolution cryoEM maps (2.5-4.8$\,Å$) from which atomic models are derived. Dehydration-induced structural changes correlate with the magnitude of solvent exposure in the native structure: interior residues present high-resolution density while surface-exposed regions rearrange. Coherent rearrangements retain secondary and tertiary structure, incoherent changes degrade resolution. These results establish ESIBD+cryoEM as viable method for structure determination of chemically selected protein samples, directly linking native MS chemical information with near-atomic structural resolution. 2025-03-28T12:14:43Z Lukas Eriksson Tim K. Esser Marko Grabarics Laurence T. Seeley Simon B. Knoblauch Jingjin Fan Joseph Gault Paul Fremdling Thomas Reynolds Justin L. P. Benesch Carol V. Robinson Jani R. Bolla Lindsay Baker Stephan Rauschenbach http://arxiv.org/abs/2603.20019v1 Design, construction, and operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory 2026-03-20T15:05:40Z Water-based Liquid Scintillator (WbLS) was proposed over a decade ago as a novel detector medium that might allow the separation and tuning of the relative ratio of the Cherenkov and Scintillation signals. A detector deploying this technology could combine GeV-scale and MeV-scale neutrino detection at scale. Furthermore, the metal-loading capability of such a material enables neutron tagging and allows the effective particle containment to be tuned. WbLS is attractive both for the potential to use it in large detectors and the ability to modify the configuration in situ. At Brookhaven National Laboratory (BNL), two prototypes have been built for understanding WbLS properties and stability, with masses of 1-ton and 30-ton, respectively. We present here the 30-ton prototype detector design, installation, and operation. Results from the analysis of data collected in the two detectors will follow in future publications. 2026-03-20T15:05:40Z 32 pages, 24 figures S. Andrade A. Baldoni D. F. Cowen R. Diaz Prerez M. V. Diwan S. Gokhale S. Gwon S. Hans P. Hackspacher J. Jerome G. Lawley G. D. Orebi Gann P. Kumar J. Park C. Reyes R. Rosero N. Seberg K. Siyeon M. Smiley R. Svoboda N. Speece-Moyer M. Vagins B. Walsh J. J. Wang M. Wilking G. Yang D. Wooley M. Yeh http://arxiv.org/abs/2603.17556v2 Characterization of Deconvolution-Based PMT Waveform Reconstruction Under Large Charge Dynamic Range and Varying Scintillation Time Profiles 2026-03-20T13:22:49Z Photomultiplier tubes (PMTs) are widely used as photon sensors for neutrino and dark matter detection. Accurate charge and time information extracted from PMT waveforms is crucial for event reconstruction. An algorithm based on deconvolution technology was proposed and applied to the reconstruction of PMT waveforms. This study further investigated the reliability of the deconvolution algorithm when handling a large charge dynamic range (0-200 photoelectrons), varying scintillation time profiles, and muon-induced large signals. Monte Carlo data confirmed that the deconvolution algorithm exhibits relatively stable reconstruction performance: the residual non-linearity of charge reconstruction is controlled to approximately 1\% over the range of 0 to 200 photoelectrons for various configurations of undershoots and scintillation time profiles, and the algorithm is capable of handling muon-induced large signals. 2026-03-18T10:03:36Z Xingyi Lin Jinghuan Xu Yongbo Huang Jingzhe Tang Tianying Xiao Yingke Li http://arxiv.org/abs/2507.05278v3 Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF 2026-03-20T12:01:58Z The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry. 2025-07-04T08:09:45Z Presented at the Tenth Meeting on CPT and Lorentz Symmetry, Bloomington, Indiana, May 15-19, 2025 T. Higuchi B. Algohi D. Anthony L. Barrón-Palos M. Bradley A. Brossard T. Bui J. Chak R. Chiba C. Davis R. de Vries K. Drury D. Fujimoto R. Fujitani M. Gericke P. Giampa R. Golub T. Hepworth G. Ichikawa S. Imajo A. Jaison B. Jamieson M. Katotoka S. Kawasaki M. Kitaguchi W. Klassen E. Korkmaz E. Korobkina M. Lavvaf T. Lindner N. Lo S. Longo K. Madison Y. Makida J. Malcolm J. Mammei R. Mammei Z. Mao C. Marshall J. W. Martin M. McCrea E. Miller M. Miller K. Mishima T. Mohammadi T. Momose T. Okamura H. J. Ong R. Patni R. Picker K. Qiao W. D. Ramsay W. Rathnakela D. Salazar J. Sato W. Schreyer T. Shima H. M. Shimizu S. Sidhu S. Stargardter P. Switzer I. Tanihata Tushar S. Vanbergen W. T. H. van Oers Y. Watanabe N. Yazdandoost Q. Ye A. Zahra M. Zhao http://arxiv.org/abs/2603.20342v1 Advanced Virgo Plus for O5 -- Design Report Overview 2026-03-20T09:57:10Z This document presents an overview of the design, implementation, and expected performance of the Advanced Virgo Plus (AdV+) upgrades in view of the O5 observing run. Following the experience gained during the O4 commissioning and operations, the Virgo Collaboration has revised the upgrade strategy to address limitations associated with marginally stable recycling cavities. The O5 upgrade program combines elements from the original AdV+ Phase II project with new design solutions, including the implementation of stable recycling cavities, a major modification to the central interferometer layout, and a comprehensive renewal of critical subsystems. The planned upgrades are organized in two steps, targeting progressive improvements in operational stability, noise reduction, and detector sensitivity. Key developments include new vacuum infrastructures, suspensions, mirrors, optical configurations, quantum noise reduction systems, and high-power laser technologies. The resulting configuration is expected to significantly enhance the interferometer performance, enabling a substantial increase in astrophysical reach and scientific return during O5. 2026-03-20T09:57:10Z F. Acernese A. Agapito D. Agarwal I. -L. Ahrend L. Aiello A. Ain S. Albanesi W. Ali C. Alléné A. Allocca W. Amar A. Amato F. Amicucci C. Amra M. Andia T. Andrić S. Ansoldi S. Antier E. Z. Appavuravther M. Arca Sedda F. Arciprete F. Armato N. Arnaud L. Asprea M. Assiduo S. Assis de Souza Melo P. Astone F. Attadio F. Aubin G. Avallone S. Babak S. Bagnasco T. Baka G. Balbi G. Baldi N. Baldicchi G. Ballardin B. Banerjee M. Baratti P. Barneo F. Barone M. Barsuglia D. Barta A. Basti M. Bawaj M. Bazzan F. Beirnaert M. Bejger D. Belardinelli C. Bellani L. Bellizzi D. Beltran-Martinez I. Bentara S. Bera S. Bernuzzi D. Bersanetti T. Bertheas A. Bertolini G. Bevilacqua V. Biancalana A. Bianchi F. Bianchi A. Binetti S. Bini S. Biot M. Bitossi M. -A. Bizouard G. Boileau M. Boldrini A. Bolliand R. Bondarescu F. Bondu R. Bonnand N. Borghi V. Boschi Y. Bothra A. Boudon A. Bozzi C. Bradaschia M. Branchesi T. Briant A. Brillet M. L. Brozzetti G. Bruno F. Bucci O. Bulashenko T. Bulik H. J. Bulten R. Buscicchio D. Buskulic C. Buy R. Cabrita G. Cagnoli E. Calloni M. Canepa G. Caneva Santoro E. Capocasa G. Capoccia G. Capurri G. Carapella F. Carbognani M. Carpinelli G. Carullo A. Casallas-Lagos J. Casanueva Diaz C. Casentini R. Cavalieri G. Cella S. Cepic P. Cerdá-Durán E. Cesarini W. Chaibi E. Chassande-Mottin S. Chaty P. Chessa F. Chiadini A. Chincarini M. L. Chiofalo A. Chiummo N. Christensen G. Ciani M. Cieślar P. Ciecielag M. Cifaldi S. Clesse F. Cleva E. Coccia E. Codazzo P. -F. Cohadon S. Colace A. Colombo L. Conti I. Cordero-Carrión S. Corezzi L. A. Corubolo A. Cozzumbo J. R. Cudell E. Cuoco M. Cusinato B. D'Angelo S. D'Antonio L. D'Onofrio D. D'Urso G. Dálya S. Dall'Osso T. Dal Canton S. Dal Pra S. Danilishin V. Dattilo A. Daumas M. Davier P. Davis J. Degallaix C. J. Delgado Mendez S. Della Torre W. Del Pozzo A. Demagny G. Demasi A. Depasse J. De Bolle M. De Laurentis F. De Lillo F. De Marco F. De Matteis R. De Pietri R. De Rosa C. De Rossi R. De Simone C. Diaz D. Diksha J. Ding M. Di Cesare L. Di Fiore M. Di Giovanni T. Di Girolamo S. Di Pace I. Di Palma D. Di Piero F. Di Renzo A. Domiciano De Souza T. Dooney O. Dorosh M. Drago M. Dubois U. Dupletsa H. Duval P. -A. Duverne M. Ebersold H. Einsle L. Errico M. Esposito F. Fabrizi V. Fafone M. Fays E. Fenyvesi T. Fernandes S. Ferraiuolo F. Fidecaro P. Figura A. Fiori I. Fiori R. Fittipaldi V. Fiumara R. Flaminio J. A. Font K. Franceschetti F. Frappez S. Frasca F. Frasconi A. Freise O. Freitas B. Gadre S. Galaudage B. Garaventa J. García-Bellido P. García Abia J. Gargiulo X. Garrido F. Garufi C. Gasbarra F. Gautier G. Gemme A. Gennai V. Gennari Archisman Ghosh S. Gkaitatzis F. Glotin S. Gomez Lopez A. Goodwin-Jones M. Gosselin C. Gostiaux R. Gouaty A. Grado M. Granata V. Granata G. Greco A. C. Green G. Grignani C. Grimaud D. Guerra D. Guetta G. M. Guidi F. Gulminelli Y. Guo N. Gutierrez M. Haney S. Harikumar T. Harmark J. Harms M. T. Hartman B. Haskell D. Hegde H. Heitmann G. Hemming J. Heynen S. Hild D. Hofman N. A. Holland L. Honet C. A. Hrishikesh W. -F. Hsu V. Hui L. Iampieri G. A. Iandolo M. Ianni G. Iannone A. Ierardi G. Iorio P. Iosif C. Jacquet P. -E. Jacquet T. Jacquot J. Janquart S. Jaraba P. Jaranowski G. Joubert V. Juste W. Kiendrebeogo G. Koekoek S. Koley A. E. Koloniari A. Koushik A. Królak E. Kraja S. L. Kranzhoff J. Kubisz A. Lakhal M. Lalleman A. Lartaux-Vollard L. Lavezzi C. Lazarte C. Lazzaro P. Leaci A. Lemaître M. Lenti M. Leonardi M. Lequime N. Leroy N. Letendre M. Lethuillier S. Lexmond M. Le Jean T. G. F. Li J. -P. Locquet A. Longo D. Lopez M. Lopez Portilla M. Lorenzini V. Loriette G. Losurdo L. Lucchesi D. Lumaca L. Lunghini A. Macquet S. S. Madekar S. Maenaut R. Maggiore M. Magnozzi E. Majorana N. Man M. Mancarella V. Mangano M. Mantovani M. Mapelli S. Marchetti C. Marinelli F. Marion S. Marsat F. Martelli M. Martinez V. Martinez A. Martini L. Massaro A. Masserot S. Mastrogiovanni G. Mastropasqua T. Matcovich L. Maurin Q. Meijer L. Mereni G. Merino M. Merzougui B. Mestichelli A. Miani C. Michel A. L. Miller E. Milotti V. Milotti Y. Minenkov Ll. M. Mir L. Mirasola C. -A. Miritescu A. L. Mitchell L. Mobilia M. Montani A. Moreso Serra G. Morras A. Moscatello B. Mours C. M. Mow-Lowry L. Muccillo F. Muciaccia D. Nabari S. Nadji A. Nagar D. Nanadoumgar-Lacroze V. Napolano I. Nardecchia H. Narola L. Naticchioni L. Negri A. Nemmani S. Nissanke F. Nocera J. Novak J. F. Nuño Siles M. Oertel G. Oganesyan M. Orselli A. Ouzriat C. Périgois L. Paiella M. A. Palaia P. P. Palma C. Palomba P. Palud P. T. H. Pang F. Pannarale M. Panzeri F. Paoletti A. Paolone L. Papalini G. Papigkiotis A. Paquis A. Parisi D. Pascucci A. Pasqualetti R. Passaquieti D. Passuello B. Patricelli A. Perego G. Perna A. Perreca J. Perret S. Perriès J. W. Perry S. Peters C. Petrillo M. Piarulli L. Piccari M. Pichot M. Piendibene F. Piergiovanni L. Pierini G. Pierra V. Pierro M. Pietrzak M. Pillas L. Pinard I. M. Pinto M. Pinto A. Placidi E. Placidi W. Plastino R. Poggiani E. Polini J. Pomper E. Porcelli E. K. Porter R. Poulton M. Pracchia T. Pradier G. Principe G. A. Prodi P. Prosperi P. Prosposito P. Puppo G. Quéméner I. Rainho A. Ramos-Buades P. Rapagnani M. Razzano T. Regimbau A. I. Renzini B. Revenu A. Revilla Peña L. Ricca F. Ricci M. Ricci A. Ricciardone S. Rinaldi F. Robinet A. Rocchi L. Rolland R. Romano A. Romero-Rodríguez L. Rosa D. Rosińska S. Roy D. Rozza P. Ruggi E. Ruiz Morales P. Saffarieh T. Sainrat S. Sajith Menon O. S. Salafia L. Salconi F. Salemi M. Sallé S. Salvador A. Samajdar N. Sanchis-Gual F. Santoliquido F. Sarandrea A. Sasli P. Sassi B. Sassolas S. Sayah V. Scacco S. Schmidt K. Schouteden M. Schulz M. Scialpi M. Seglar-Arroyo J. W. Seo V. Sequino M. Serra A. Sevrin N. S. Shcheblanov L. Silenzi L. Silvestri V. Sipala L. Smith S. Soares de Albuquerque Filho V. Sordini F. Sorrentino F. Spada V. Spagnuolo P. Spinicelli D. A. Steer J. Steinlechner S. Steinlechner N. Stergioulas P. Stevens M. Suchenek S. Sudhagar J. Suresh A. Svizzeretto B. L. Swinkels A. Syx M. J. Szczepańczyk P. Szewczyk M. Tacca M. Tagliazucchi I. Takimoto Schmiegelow N. Tamanini E. N. Tapia San Martín C. Taranto A. Theodoropoulos J. Tissino P. Tiwari E. Tofani M. Toffano A. Torres-Forné I. Tosta e Melo E. Tournefier M. Trad Nery A. Trapananti R. Travaglini F. Travasso M. C. Tringali G. Troian A. Trovato L. Trozzo K. Turbang M. Turconi C. Turski H. Ubach M. Vacatello M. Valentini E. Vallejo-Pagès S. Vallero M. van Dael E. Van den Bossche J. F. J. van den Brand C. Van Den Broeck M. van der Kolk M. van der Sluys A. Van de Walle J. van Dongen H. van Haevermaet J. V. van Heijningen P. Van Hove N. van Remortel M. Vardaro G. Vedovato S. Venikoudis P. Verdier M. Vereecken D. Verkindt F. Vetrano A. Veutro A. Viceré N. Villanueva Espinosa J. -Y. Vinet S. Viret H. Vocca M. Was M. Wils J. Woehler I. C. F. Wong T. Wouters M. Wright Z. Wu N. Yadav T. Zelenova J. -P. Zendri M. Zeoli M. Zerrad Y. Zhao L. Zimmermann http://arxiv.org/abs/2603.03088v2 Using a Stifneck Select Collar$^{\mathrm{TM}}$ for hands-free semiautomatic blood flow measurements: a user study 2026-03-20T08:22:50Z Objective: The percentage of long-term survival in out of hospital cardiac arrest cases is remarkably low. One approach would be to increase the effectiveness of cardiopulmonary resuscitation (CPR), which is currently not measurable in a quantifiable way. The most significant challenge in providing a mobile solution for CPR evaluation is a mobile, hazard free sensor attachment with high usability. Methods: We present a sensor attachment solution usable for semiautomatic ultrasonic (US) Doppler measurements. Components are attached to a Stifneck Select Collar$^{\mathrm{TM}}$ (Laerdal). An inflatable cushion (TR-Band$^{\mathrm{TM}}$, Terumo) allows adjustable contact pressure. A clinical study was conducted in which the system was evaluated based on comfort, pain, sensor support, the viability of Doppler signals, and the absence of skin irritations. Results: The system was utilized in a prospective study involving 102 healthy probands. On a scale between 1 (Low) and 10 (Intense), ratings were 1.19 (SD 0.46), 6.52 (SD 1.78), and 9.95 (SD 0.32) for pain, comfort, and support, respectively. The average duration of application was 31.19 minutes (SD 16.75 minutes). Audible Doppler signals were achieved in 92.2 % of the probands, and Doppler curve evaluation was usable in 73.5 %. No skin irritations were observed. Conclusion: A hands free sensor attachment for a US probe was developed that caused no significant complaints by healthy study volunteers. Medical users assessed its attachment as robust. Significance: With its adjustable positioning and easy attachment, the Stifneck modification can form a basis for a mobile US Doppler device, capable of evaluating carotid artery flow during CPR. 2026-03-03T15:30:48Z 7 pages, 6 figures, 3 tables Reinhard Fuchs Nathalie Sumrah Maximilian N. Möbius-Winkler Georg Stachel Michael Schultz Ulrich Laufs Thomas Neumuth Michael Unger Karsten Lenk http://arxiv.org/abs/2512.04432v3 Design and Performance Simulation of the Electromagnetic Calorimeter at EicC 2026-03-20T03:39:32Z The electromagnetic calorimeter (ECAL) is a key detector component for precise electron and photon measurements in electron-ion collision experiments. At the Electron-Ion Collider in China (EicC), high-performance calorimetry is essential for exploring the internal structure of nucleons and studying the dynamics of quarks and gluons within quantum chromodynamics (QCD). This paper presents the optimized design and performance simulation of the EicC ECAL system. The ECAL consists of three specialized sections tailored to distinct detection environments: (1) an electron-Endcap employing high-resolution pure Cesium Iodide (pCsI) crystals, (2) a central barrel, and (3) an ion-Endcap, both adopting a cost-effective Shashlik-style sampling calorimeter with improved light yield. Each segment's geometry and material composition have been systematically optimized through Geant4 simulations to achieve excellent energy and position resolutions as well as strong electron-pion discrimination. The simulated performance indicates that the ECAL can achieve energy resolutions of 2 percent divided by sqrt(E) for pCsI crystals and 5 percent divided by sqrt(E) for Shashlik modules, meeting the design goals of the EicC detector. 2025-12-04T03:55:34Z Ye Tian Souvik Maity Jingyu Li Yuancai Wu Shan Sha Yutie Liang Aiqiang Guo Yuxiang Zhao Dexu Lin http://arxiv.org/abs/2603.23546v1 Offline Commissioning of the St. Benedict Gas Catcher 2026-03-19T20:23:21Z Precision measurements of $β$ decay transitions offer a promising channel through which the Standard Model (SM) can be probed. There is currently an ongoing effort to increase the precision on measurements of $\mathcal{F}t$-values for superallowed $β$ decay transitions between mirror nuclides. These allow for a determination of $V_{ud}$ which is complementary to that obtained from pure Fermi $0^+ \rightarrow 0^+$ transitions. The Superallowed Transition BEta-NEutrino Decay Ion Coincidence Trap (St. Benedict), under construction at the Nuclear Science Laboratory (NSL) at the University of Notre Dame, seeks to measure the Fermi-to-Gamow-Teller mixing ratio for transitions between mirror nuclei in order to expand the list of nuclides from which $V_{ud}$ can be extracted. Production and selection of the species of interest will be done in-flight, using the \textit{TwinSol} magnetic separator system. The first element of St. Benedict will be a large volume gas catcher which will thermalize radioactive ion beams for low energy delivery to the rest of the system. Offline commissioning of this gas catcher has been completed using an internal potassium source, and the device demonstrated a transport efficiency upwards of 95\% for pressures of 66 mbar and lower. 2026-03-19T20:23:21Z 9 pages, 12 figure, 3 tables F. Rivero D. Guillet M. Brodeur J. A. Clark A. M. Houff J. J. Kolata B. Liu J. McRae P. D. O'Malley W. S. Porter C. Quick G. Savard A. A. Valverde R. Zite http://arxiv.org/abs/2603.24607v1 Physics at the Edge: Benchmarking Quantisation Techniques and the Edge TPU for Neutrino Interaction Recognition 2026-03-19T18:50:39Z This work presents a comprehensive benchmark of different quantisation techniques for convolutional neural networks applied to neutrino interaction recognition. Utilising simulation for a generic liquid argon time-projection chamber, models are quantised and then deployed on the Google Coral Edge TPU. Four Keras models are tested, and accuracy is measured across two different pipelines: using post-training integer quantisation and quantisation-aware training. Inference speed is benchmarked against an AMD EPYC 7763 CPU and NVIDIA A100 GPU. A study of the energy consumption is also presented, with attention to potential costs and environmental issues. Results show that, among the four models tested, accuracy degradation is limited and, in particular, Inception V3 presents almost no accuracy degradation across the two quantisation and deployment pipelines. The speed of the edge TPU is comparable to that of the CPU, and one order of magnitude slower than the GPU. Moreover, the energy consumption of all models deployed on the edge TPU is several orders of magnitude lower than that of the CPU and GPU. In the energy consumption-latency parameter space, CPU, GPU, and edge TPU performances can be clearly separated. This paper explores possible future integrations of edge AI technologies with neutrino physics. 2026-03-19T18:50:39Z Stefano Vergani Hilary Utaegbulam Michael Wang Leigh H. Whitehead Arden Tsang Lorenzo Uboldi http://arxiv.org/abs/2603.18993v1 A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference 2026-03-19T15:00:01Z The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB. 2026-03-19T15:00:01Z Submitted to IEEE Instrumentation and Measurements. 8 pages, 10 figures, previous publication: arXiv:2304.13088 Fabricio Alcalde Bessia Claudio Chavez Troy England Hongzhi Sun Andrew Lathrop Davide Braga Miguel Sofo-Haro Juan Estrada Farah Fahim