https://arxiv.org/api/URSsIqnSePXpcRd0wuHNneukNVI2026-03-28T12:29:32Z240683015http://arxiv.org/abs/2601.12819v3Validation of the COSINE-100U NaI(Tl) Encapsulation for Low-Temperature Operation in Liquid Scintillator2026-03-24T12:29:15ZThe COSINE-100U (upgrade) will enhance the sensitivity of the COSINE-100 dark matter search by operating the detector array immersed in liquid scintillator (LS) at $-30^oC$. To validate the detector design for these conditions, we constructed a module using the COSINE-100U encapsulation and performed a dedicated long-term stability study. The module was first monitored at room temperature for ~110 days in air, followed by a one-week immersion in LAB-based LS to verify initial compatibility. Upon confirming stable optical performance, the temperature was lowered to $-33^oC$. During approximately 150 days of continuous operation at low temperature, we observed no degradation in performance. These results demonstrate the chemical and mechanical robustness of the encapsulation, confirming its suitability for the COSINE-100U physics run.2026-01-19T08:28:49Z11 pages, 5 figuresKihong ParkSungjin ChoLuis Eduardo FrancaChang Hyon HaJinyoung KimKyungwon KimSungHyun KimWon Kyung KimYoung Ju KoDoohyeok LeeHyun Su LeeIn Soo LeeSeo Hyun LeeSe Dong ParkGyun Ho Yuhttp://arxiv.org/abs/2602.09037v3Inverse Design of Three-Dimensional Microwave Cavities for Optimizing Electromagnetic Helicity2026-03-24T03:39:19ZWe present a inverse-design framework framework for systematically engineering three-dimensional microwave cavity resonators that support modes with nonzero electromagnetic helicity. In contrast to heuristic approaches to cavity design, helicity maximisation is formulated as a boundary-shape optimisation problem, enabling systematic exploration of complex boundary-shape parameter spaces and the identification of high-helicity designs that are difficult to predict using heuristic design rules alone. We applied this framework to several cavity families composed of smooth, edge-free components, including globally twisted cavities with control-point-defined cross-sections realised in both linear and ring configurations, cavities defined by the intersection of orthogonal prisms, sphere-subtracted cylindrical cavities, and parametrised surface resonators. Two gradient-free optimisation strategies, a genetic algorithm and Bayesian optimisation, were independently employed to explore compact sets of design parameters for these geometries and to optimise a scaled-helicity figure of merit for the dominant helical mode, evaluated via finite-element eigenmode analysis. Robustness to manufacturing tolerances was quantified by applying Gaussian geometric perturbations to the optimised cavities and evaluating statistical robustness metrics that penalise sensitivity to geometric variation. The optimisation reveals clear physical design principles governing the generation of high electromagnetic helicity in three-dimensional microwave cavities.2026-01-30T03:56:20Z15 pages, 6 figuresEmma PatersonJeremy BourhillMaxim Goryachevhttp://arxiv.org/abs/2603.22595v1The CYGNO experiment: a gaseous TPC with optical readout for rare events searches2026-03-23T21:41:10ZThe CYGNO collaboration is developing a novel strategy for directional Dark Matter searches based on a gaseous Time Projection Chamber (TPC). The detector is optimized for the exploration of light (0.5-50 GeV) WIMPs-like particles and employs a He/CF4 gas mixture at atmospheric pressure, sensitive to both spin-dependent and spin-independent interactions. A key feature of the project is its optical readout, which relies on photon detection rather than charge collection. In CYGNO detectors, electrons released by ionizing tracks drift toward an amplification stage of three Gas Electron Multipliers (GEMs). The electron avalanches generate scintillation light that is captured by scientific CMOS (sCMOS) cameras for high-resolution two-dimensional imaging and by Photomultiplier Tubes (PMTs) that provide a precise time profile along the drift direction. This allows a 3D event reconstruction, detailed energy deposition mapping, and effective topology and head-to-tail discrimination. Building on the achievements of the 50 L prototype (LIME), which successfully operated underground at LNGS, the next step is the deployment of a 0.4 m3 demonstrator, CYGNO-04, to be completed in 2026. The demonstrator will validate scalability and confirm the advantages of the proposed technique. Recent results from LIME highlight strong progress in 3D tracking and particle identification. The current status of CYGNO-04 and its role in advancing the program will be presented as well.2026-03-23T21:41:10ZF. D. AmaroR. AntoniettiE. BaracchiniL. BenussiC. CapocciaM. CaponeroL. G. M de CarvalhoG. CavotoI. A. CostaA. CroceM. D'AstolfoG. D'ImperioG. DhoE. Di MarcoJ. M. F. dos SantosD. FiorinaF. IacoangeliZ. IslamH. P. LimaG. MaccarroneR. D. P. ManoD. J. G. MarquesG. MazzitelliP. MeloniA. MessinaC. M. B. MonteiroR. A. NobregaI. F. PainsE. PaolettiF. PetrucciS. PiacentiniD. PierluigiD. PinciF. RengaA. RussoG. SavianoP. A. O. C. SilvaN. J. C. SpoonerR. TesauroS. TomassiniS. TorelliD. Tozzihttp://arxiv.org/abs/2412.09639v2Progress in Decompositional Electromagnetic Analysis of Digital Interconnects2026-03-23T18:59:24ZIn the realm of PCB and packaging interconnect design, electromagnetic analysis tools have transitioned from optional to essential over the last two decades, as data rates soared beyond 6 Gbps. Today, with standard data rates eclipsing 6 Gbps and reaching thresholds of 224 Gbps, these tools are indispensable for designing reliable interconnects. The goals of the interconnect analysis are simple: identify interconnects that may fail at the target data rate and allow troubleshooting and fixing the problem. The most efficient approach to such pass-fail analysis is the Decompositional Electromagnetic Analysis (DEA). It allows separation of the signal degradation factors for faster analysis and troubleshooting. This paper outlines the basic elements of DEA, discusses conditions for its accuracy and underscores its significance in the future of interconnect design.2024-12-07T19:23:58ZAccepted at 2026 IEEE EMC+SIPI. (c) 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or listsYuriy Shlepnevhttp://arxiv.org/abs/2603.22390v1Dark Matter Detection Using Phonon Sensing in Amorphous Materials2026-03-23T18:00:07ZWe present a concept for a tabletop-scale detector with an amorphous target designed to search for dark matter absorption into phonon excitations. In crystalline materials, absorption occurs only at narrow resonances where the dark matter mass matches a zero momentum optical phonon mode, whereas amorphous targets provide a broadband response that can substantially enhance the absorption rate away from these resonances. The predicted backgrounds arise from the relaxation of disorder-induced metastable defects in the amorphous target, as well as from low-energy noise intrinsic to superconducting phonon sensors. A prototype detector with a target mass of only a few $μ$g could provide broadband sensitivity to dark photon absorption across the 50 meV-200 meV mass range, probing up to two orders of magnitude beyond existing constraints.2026-03-23T18:00:07Z16 pages, 10 figuresItay M. BlochSimon KnapenXinran LiAmalia MaddenGiacomo Maroccohttp://arxiv.org/abs/2603.22253v1Polymer identification via undetected photons using a low footprint nonlinear interferometer2026-03-23T17:45:07ZPlastic pollution has become a critical global challenge, with microplastics pervading ecosystems and entering human food chains. Effectively monitoring this widespread contamination demands rapid, reliable, and portable material identification techniques that often elude conventional Raman and FTIR spectroscopy. Undetected photon spectroscopy within a nonlinear interferometer (NLI) offers a solution, allowing the retrieval of mid-infrared absorption spectra by detecting only near-infrared signal photons using standard silicon-based technology. Here, we demonstrate a highly compact, micro-integrated, thermally-stabilised NLI with a Michelson-like geometry designed for the rapid spectroscopy of plastics. We benchmarked its room-temperature performance, demonstrating a signal-to-noise ratio of 34 with a measurement rate of 100 Hz and a spectral resolution of 6 cm$^{-1}$. We show that we can accurately and rapidly retrieve the characteristic vibrational absorption spectra of common polymers such as polypropylene, polyethene, and polystyrene, without using mid-infrared technology. These results establish our compact module as a promising field-deployable platform for robust, real-time environmental monitoring systems and other mid-infrared spectroscopy applications.2026-03-23T17:45:07Z11 pages, 9 figuresAtta Ur Rehman SherwaniEmma PearcePhilipp HildensteinFelix MauerhoffAlexander SahmKatrin PaschkeHelen M. ChrzanowskiSven Ramelowhttp://arxiv.org/abs/2603.23553v1Methods for an Electron Emission Digital Twin2026-03-23T15:57:48ZThe effective design and operation of electron emitters is the core of critical technologies such as high-resolution electron imaging and spectroscopy or X-ray production for medical imaging. Despite 100 years of theoretical development in thermo- and field-electron emission models, the analysis of experimental data and design of electron emitters remains an art more than a science. This is due to the many processes that are involved in electron emission, which result in an extremely complex phenomenon. Here we describe and develop the Methods for an Electron Emission Digital Twin (MEEDiT), which integrates state-of-the-art thermo-field electron emission models and experimental data characterisation. By applying MEEDiT to silicon electron emitters, we demonstrate an approach that bridges the gap between simple experimental measurements and 'hidden' physical quantities like temperature and field enhancement. MEEDiT provides the physical consistency of a 3D simulation with the speed of a neural network, enabling resource-effective, real-time characterization and the extraction of critical data that is otherwise inaccessible during operation.2026-03-23T15:57:48Z10 pages, 3 figuresSalvador Barranco CarcelesVeronika ZadinSteve WellsAquila MavalankarIan UnderwoodAnthony Ayarihttp://arxiv.org/abs/2603.22080v1Standalone optical frequency-offset locking electronics for atomic physics2026-03-23T15:13:43ZWe present a standalone frequency-offset locking system for controlling narrow-linewidth lasers using off-the-shelf electronic components. We lock two frequency-doubled 1560 nm lasers to a stable primary laser operating at 780 nm via their optical beat note. This radio-frequency beat note is fed through a broadband variable divider, a frequency-to-voltage converter, and a proportional-integrator controller to lock each follower laser to a tunable offset frequency relative to the primary. This architecture provides a large capture range ($> 1$ GHz), fast response times ($< 1$ ms), and high linearity. We achieve a frequency resolution of 1.9 kHz and a short-term fractional frequency instability $10^{-11}/\sqrt{τ\rm (s)}$ at 780 nm without the need for a dedicated, precise clock reference. We perform high-resolution spectroscopy of cold $^{87}$Rb atoms to demonstrate the tunability and precision of our locking system. We designed the system to be modular and extensible, making it applicable to a wide variety of atomic physics experiments, including laser cooling, spectroscopy, and quantum sensing with atoms, ions, and molecules.2026-03-23T15:13:43Z9 pages, 8 figures, accepted in Review of Scientific Instruments. Circuit designs are available from the following repository: 10.5281/zenodo.18876772Rev. Sci. Instrum. 97, 033004 (2026)K. ShalabyT. HuntS. MoirP. TrottierT. ReuschelB. Barrett10.1063/5.0321289http://arxiv.org/abs/2603.21982v1Hyperloss from coherent spatial-mode mixing in quantum-correlated networks2026-03-23T13:45:07ZQuantum-correlated networks distribute quantum resources such as squeezed and entangled states. These states are central to modern quantum technology, including photonic quantum computing, quantum communications, non-destructive biological sensing and gravitational-wave detection. Even for squeezed states of light - the most robust quantum-correlated resource - loss-induced decoherence remains the dominant obstacle to strong quantum advantage in in large-scale interferometric and networked quantum systems. Common design assumption in these applications is treating mismatches between spatial modes as a small, incoherent loss. Here we show that this picture can fail: coherent spatial-mode mixing with higher-order spatial modes can produce an apparent loss exceeding 100% relative to the initial squeezing, a regime we term hyperloss.
We experimentally demonstrate hyperloss in a minimal two-node quantum network: with only 8% mode mismatch, a 5.8dB squeezed state is converted into an effectively thermal state with no quadrature squeezing, eliminating the quantum advantage. Because the effect is coherent, it is controllable: lost correlations can be recovered by tuning differential spatial-mode phases (e.g., Gouy-/propagation-phase). We demonstrate this recovery experimentally, not only eliminating the hyperloss, but even significantly suppressing the mode mismatch loss, with 15% geometric mismatch acting like only ~2.8% effective loss.
Hyperloss is a design-limiting mechanism for all quantum networks with squeezed light, from from photonic quantum processors to large-scale interferometers and distributed quantum-sensing networks. Our results provide a practical route to avoid hyperloss and turn mode mismatch into an explicit, phase-aware design parameter for future quantum technologies.2026-03-23T13:45:07ZStephan GrebienJulian GursRoman SchnabelMikhail Korobkohttp://arxiv.org/abs/2603.21848v1PhotonPix: Single-Photon Detector with 10 ps timing precision and high dynamic range2026-03-23T11:37:27ZA plug-and-play PhotonPix single-photon detector with a logical signal output is developed for applications requiring ultimate timing precision down to 10 ps over a wide dynamic photon flux range. The heart of the detector is an Exosens Fast Timing Microchannel Plate Photomultiplier (FT MCP-PMT) with a large 8 mm diameter sensitive area, which can accommodate various Hi-QE photocathodes optimized for high quantum efficiency (QE) and low dark rates. The detector dead time, timing accuracy, and counting efficiency of the PhotonPix are measured and analyzed over a wide dynamic photon flux range up to about 1 GHz in burst mode and up to 100~MHz in continuous operation mode.2026-03-23T11:37:27Z5 pages, 4 figures. 7th international workshop on new Photon-Detectors, 3-5 December 2025 Bologna, ItalyD. A. OrlovY. ProkazovE. TurbinE. Kernenhttp://arxiv.org/abs/2601.20626v2Trigger Optimization and Event Classification for Dark Matter Searches in the CYGNO Experiment Using Machine Learning2026-03-23T11:23:36ZThe CYGNO experiment employs an optical-readout Time Projection Chamber (TPC) to search for rare low-energy interactions using finely resolved scintillation images. While the optical readout provides rich topological information, it produces large, sparse megapixel images that challenge real-time triggering, data reduction, and background discrimination.
We summarize two complementary machine-learning approaches developed within CYGNO. First, we present a fast and fully unsupervised strategy for online data reduction based on reconstruction-based anomaly detection. A convolutional autoencoder trained exclusively on pedestal images (i.e. frames acquired with GEM amplification disabled) learns the detector noise morphology and highlights particle-induced structures through localized reconstruction residuals, from which compact Regions of Interest (ROIs) are extracted. On real prototype data, the selected configuration retains (93.0 +/- 0.2)% of reconstructed signal intensity while discarding (97.8 +/- 0.1)% of the image area, with ~25 ms per-frame inference time on a consumer GPU.
Second, we report a weakly supervised application of the Classification Without Labels (CWoLa) framework to data acquired with an Americium--Beryllium neutron source. Using only mixed AmBe and standard datasets (no event-level labels), a convolutional classifier learns to identify nuclear-recoil-like topologies. The achieved performance approaches the theoretical limit imposed by the mixture composition and isolates a high-score population with compact, approximately circular morphologies consistent with nuclear recoils.2026-01-28T14:00:35Z6 pages, 1 figure. Proceedings of 14th Young Researcher Meeting (14YRM2025). Published in PoS(14YRM2025)003 (2026); updated to match published versionPoS(14YRM2025)003 (2026)F. D. AmaroR. AntoniettiE. BaracchiniL. BenussiC. CapocciaM. CaponeroL. G. M. de CarvalhoG. CavotoI. A. CostaA. CroceM. D'AstolfoG. D'ImperioG. DhoE. Di MarcoJ. M. F. dos SantosD. FiorinaF. IacoangeliZ. IslamE. KempH. P. LimaG. MaccarroneR. D. P. ManoD. J. G. MarquesG. MazzitelliP. MeloniA. MessinaC. M. B. MonteiroR. A. NobregaG. M. OppedisanoI. F. PainsE. PaolettiF. PetrucciS. PiacentiniD. PierluigiD. PinciF. RengaA. RussoG. SavianoP. A. O. C. SilvaN. J. SpoonerR. TesauroS. TomassiniD. Tozzi10.22323/1.519.0003http://arxiv.org/abs/2512.15264v2Channel-Level Calibration Methods of Silicon Photomultiplier for JUNO-TAO Central Detector2026-03-23T03:52:14ZThe Taishan Antineutrino Observatory (TAO or JUNO-TAO) is a satellite observatory for the Jiangmen Underground Neutrino Observatory (JUNO), located 44 meters away from the No.1 reactor of the Taishan Nuclear Power Plant. TAO can measure the reactor antineutrino energy spectrum with excellent energy resolution (better than 2\% at 1 MeV) using state-of-the-art Silicon Photomultipliers (SiPMs) operated at low temperature. To achieve this goal, the SiPMs (together with their readout electronics) must be well calibrated. This paper presents the channel-level calibration methods for the dark count rate (DCR), relative photon detection efficiency (PDE), time offset, gain, and internal optical crosstalk (IOCT) of the SiPMs based on charge and time information of the collected events. For the calibration of the external optical crosstalk (EOCT), in terms of its rate and emission angle distribution, a novel method is proposed by switching on and off different groups of SiPMs with an LED placed in the detector. Using one million simulated events, the expected calibration biases are evaluated for all the aforementioned parameters: relative PDE (2.1\%), IOCT (1.4\%), DCR (0.4\%), EOCT Rate ($<0.1\%$), gain ($<0.1\%$), time offset (0.027 ns). The emission angle distribution of the EOCT photons could be measured with a bias of less than 4\% in main angular range.2025-12-17T10:13:18ZJiayang XuYichen LiZhan LiangGuofu CaoZelin Chenhttp://arxiv.org/abs/2603.21057v1Robust Quantum Sensing via Prethermal Spin Orbits2026-03-22T04:51:40ZPractical performance of quantum sensors is often curtailed by uncontrolled environmental drift (bias-field instability, temperature fluctuations, mechanical vibration), background fields, and imperfect control pulses. This motivates developing physical mechanisms that intrinsically compensate for such perturbations while retaining high sensitivity to target fields. We introduce an interaction-protected magnetometry scheme where periodic driving steers the collective magnetization onto two long-lived, prethermal Floquet "orbit" axes well-separated on the Bloch sphere. Rapid toggling between these axes encodes target fields as a differential signal, whereas background fields appear as common-mode motion that is strongly rejected, achieving >1000-fold suppression while canceling prethermal transients. This enables accurate reconstruction of rapidly varying audio-band magnetic signals without predictive filtering or spectral tuning. We provide an experimental proof-of-principle using a dense ensemble of coupled nuclear spins, operated here as a broadband (0-1 kHz) magnetometer. The protocol is remarkably tolerant to imperfections, operating robustly across millions of pulses under pulse-angle (~10°) and pulse frequency (>1 kHz) errors, large bias-field drifts (>50 $\mathrmμ$T), temperature variations over 150 K, and harsh mechanical vibrations. These results establish Floquet prethermalization as a resource for robust quantum sensors that combines broadband magnetic-field sensitivity with intrinsic immunity to diverse environmental and control perturbations, opening a path toward stable quantum metrology beyond controlled laboratory conditions.2026-03-22T04:51:40ZEnrico Daniel RichterRyan J. SmithBrayden GlockzinEmanuel DrugaThomas SchenkelAshok Ajoyhttp://arxiv.org/abs/2601.16822v2Design and characterization of the POKERINO prototype for the POKER/NA64 experiment at CERN2026-03-21T15:09:46ZThe NA64 experiment at CERN H4 beamline recently started a high-energy positron-beam program to search for light dark matter particles through a thick-target, missing-energy measurement. To fulfil the energy resolution requirement of the physics measurement $σ_E/E\simeq2.5\%/\sqrt{E\mathrm{[GeV}]} \oplus 0.5\%$ and cope with the constraints and performance requests of the NA64 setup, a new high-resolution homogeneous electromagnetic calorimeter PKR-CAL has been designed. The detector is based on PbWO$_4$ crystals, each read by multiple SiPM sensors to maximize the light collection. The PKR-CAL design has been optimized to mitigate and control unavoidable SiPM saturation effects at high light levels, as well as to minimize the gain fluctuations induced by instantaneous variations of the H4 beam intensity. The $R\&D$ program culminated in the construction of a small-scale prototype, POKERINO. In this work, we present the results from the experimental characterization campaign of the POKERINO aiming at demonstrating that the obtained performances are compatible with the application requirements.2026-01-23T15:20:39ZAndrei AntonovPietro BisioMariangela BondìAndrea CelentanoAnna MariniLuca Marsicanohttp://arxiv.org/abs/2603.20797v1Testing and Characterization of Wafer-Scale MAPS Prototypes for the ALICE ITS3 Upgrade2026-03-21T12:44:04ZThe ALICE experiment will upgrade the innermost three layers of its vertexing detector, the Inner Tracking System (ITS), during the next LHC Long Shutdown (LS3) with a novel, bent, ultra-light MAPS-based tracker. Six wafer-scale sensor chips will be bent into three cylinders, held in place only by carbon foam, leaving no material except for the silicon die in most of the ALICE central barrel acceptance. Two prototype ASICs, approximately $25.9\,\mathrm{cm}$ in length, called MOSS (MOnolithic Stitched Sensor) and MOST (MOnolithic Stitched sensor with Timing), have been produced. These two chips follow complementary approaches to evaluate the use of stitched CMOS sensors for the first time in an HEP experiment.
This article gives an overview of powering tests, functional studies, pixel matrix characterization, and in-beam tests of both test structures. The overall yield of MOSS is measured to be approximately $76\,\%$ per region (1/80th of a chip). This number takes into account powering, as well as functional aspects such as digital and analog pulsing. Two major failure modes have been identified and understood: short in the power grid of the chip and readout issues, that can be clearly attributed to the readout architecture design. Disregarding these issues, the overall yield increases to about $98\,\%$ per region. Furthermore, it is shown that MOSS can operate with $>99\,\%$ efficiency and $<10^{-1}\,\mathrm{hits/pixel/s}$ fake-hit rate up to $4\,\mathrm{kGy}$ TID and $4\times 10^{12}\,\mathrm{1~MeV~n_{eq}~cm^{-2}}$ NIEL.
The MOST prototype successfully demonstrated use of power gating, which allows for disconnected parts of the pixel matrix from the power grid in case of shorts. MOSS and MOST successfully proved that designing stitched wafer-scale sensors is feasible and deliver valuable input for the design of the final ITS3 ASIC.2026-03-21T12:44:04ZProceedings for The 14th international "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD-14)Nicolas Tiltmannon behalf of the ALICE collaboration