https://arxiv.org/api/URSsIqnSePXpcRd0wuHNneukNVI2026-09-10T19:14:21Z248683015http://arxiv.org/abs/2608.19064v2Exploring the limits of high-energy proton-pion separation in granular calorimeters2026-09-05T06:20:43ZHighly granular calorimeters provide detailed information about hadronic-shower development that may enable particle identification beyond their conventional role in energy measurement. We investigate how well this information can distinguish protons from positively charged pions and how the achievable discrimination depends on detector segmentation and particle energy. The study uses Geant4 simulations of isolated particles with energies from 10 to 100 GeV in a homogeneous lead-tungstate calorimeter. A Deep Sets model operating directly on cell positions and detected energy and time outperforms a boosted decision tree based on reconstructed shower observables. With cells measuring $3 \times 3 \times 6$ mm$^3$, Deep Sets achieves an accuracy of 93.8% at 10 GeV, decreasing to 67.2% at 100 GeV. Shower topology is independently informative, deposited energy provides the largest additional contribution, and timing supplies complementary information. Coarser segmentation reduces discrimination, with performance more sensitive to longitudinal than transverse granularity. These results provide an encouraging benchmark for calorimeter-based hadron identification and motivate its inclusion among the optimization targets for future highly granular calorimeters.2026-08-19T16:06:11ZAndrea De Vita AbhishekTommaso DorigoPietro Vischiahttp://arxiv.org/abs/2609.05840v1An optical cryostat for automated testing of silicon photomultipliers with vacuum-ultraviolet light2026-09-05T03:09:41ZWe present the design and performance of an optical cryostat for testing silicon photomultipliers (SiPMs) with vacuum-ultraviolet (VUV) light. The cryostat operates within a temperature range of 120 to 340 K, achieving a temperature stability of 1.2 mK, measured in a rolling 10-minute window once settled within a liquid nitrogen fill-cycle, and 13.8 mK over a complete fill-cycle including the refill transient. The cryostat includes a VUV-transparent CaF$_2$ viewport with a 142 mm diameter clear aperture, which limits the optically accessible sample area to 158 cm$^2$. The viewport is integrated into a sealed dark box and optical table to facilitate light delivery. VUV illumination is achieved using a custom xenon scintillation lamp or a xenon flash lamp, with a motorized two-axis linear rail system ensuring precise light positioning over the sample. This paper details the cryostat and optical system design, as well as commissioning current-voltage (IV) measurements using Hamamatsu VUV-sensitive SiPMs from 165 to 295 K and a measurement of the photodetection efficiency at 165 K.2026-09-05T03:09:41ZLucas DarrochRiya RaiSoud Al KharusiMegan MarquisSebastian EppeltIskender IsikbayXiao ShangTsvetelin TotevNaman WaliaThomas Brunnerhttp://arxiv.org/abs/2603.25436v2Real-Time Wiener Deconvolution for feature reconstruction in JUNO2026-09-04T21:23:07ZIn particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.2026-03-26T13:29:02ZL. LastrucciM. GrassiA. TriossiJ. HuX. JiangR. BrugneraA. GarfagniniV. CerroneL. V. D'AuriaA. GavrikovR. M. GuizzettiA. SerafiniG. AndronicoV. AntonelliA. BarresiD. BasilicoM. BerettaA. BergnoliM. BorghesiA. BrigattiR. BrunoA. BudanoB. CaccianigaA. CammiR. CarusoD. ChiesaC. ClementiC. ColettaS. DusiniA. FabbriG. FeliciG. FerranteM. G. GiammarchiN. GiudiceN. GuardoneF. HouriaA. IslamC. LandiniI. LippiL. LoiP. LombardiF. MantovaniS. M. MariA. MartiniL. MiramontiM. MontuschiM. NastasiD. OrestanoF. OrticaA. PaoloniL. PelicciE. PercalliF. PetrucciE. PrevitaliG. RanucciA. C. ReB. RicciA. RomaniC. SirignanoM. SistiL. StancoE. Stanescu FarillaV. StratiM. D. C. TorriC. TuvèC. VenettacciG. VerdeL. VotanoG. DongJ. DongL. FanS. HouZ. NingY. SunY. WangZ. WangX. Yanhttp://arxiv.org/abs/2609.05674v1The DarkLight Experiment at TRIUMF2026-09-04T19:14:06ZThis paper reports on the commissioning of the DarkLight experiment at the ARIEL superconducting electron linear accelerator located at TRIUMF in Vancouver, Canada. DarkLight was designed to utilize the ARIEL electron beam to search for a new boson, $A^\prime$, which preferentially couples to leptons, with a mass in the range 13-17 MeV/$c^2$. Such a boson could be produced via the $e^-~X\rightarrow e^-~X~A^\prime$ process, and the resulting $A^\prime\rightarrow e^+~e^-$ decay used to reconstruct the invariant mass of the $A^\prime$. The $e^+e^-$ pair is detected using a pair of magnetic spectrometers. Each spectrometer is instrumented with two triple GEM detectors and a scintillating strip hodoscope to trigger the event readout. Electron beam energies between 10 and 30 MeV were used to commission the experiment with a 1$~μ$m thick carbon target. With both spectrometer polarities set to select electrons, elastic and Møller scattering were used to examine detector performance and compare with predicted distributions from Monte Carlo simulations. Planned upgrades to the e-linac will allow searches to be made with beam energies up to 50 MeV using a 1$~μ$m thick tantalum target.2026-09-04T19:14:06Z21 pages and 27 figuresR. AlarconD. AlmonteM. I. AlstatyJ. AzziR. BaartmanJ. C. BernauerX. BraunD. CiarnielloC. ClabeauxE. W. ClineE. CoreyR. CorlissW. DeconinckA. DeshpandeJ. DillingJ. DodgeD. H. DongwiC. EkemanE. A. FieldingS. FrantzenI. FriščićG. GelinasS. GelinasK. GillA. Sabzevari GonzalezS. GupteD. K. HasellM. HasinoffB. HumphriesE. IhloffN. JacksonD. JayakodigeR. Kanungo J. E. KelseyO. KesterM. KohlH. W. KoayR. LaxdalL. LevackX. LiW. LinC. MaA. MahonH. MerkelJ. W. MartinL. MillerR. MilnerK. OlchanskiK. PachalT. PlancheD. PreddyS. D. RädelG. RandallJ. RedingerD. A. ReiterR. RichardsB. ScullyS. ShapiroM. SureshC. VidalS. WangH. WitteH. YangS. Yenhttp://arxiv.org/abs/2606.05333v2The MuFusE Large-Volume Diamond Anvil Cell for Exploring Muon-Catalyzed Fusion at Higher Pressures and Temperatures2026-09-04T18:17:22ZA new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion ($μ$CF) Experiment (MuFusE), enabling the compression and heating of deuterium-tritium (d-t) mixtures to pressures and temperatures needed to advance $μ$CF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm$^3$ at liquid density, pressures up to 933 MPa and temperatures up to 400 K - benchmarks that significantly exceed previously reported limits for static d-t targets.2026-06-03T18:19:27Z9 Pages, 11 figures. Submitted to to Review of Scientific InstrumentsRev. Sci. Instrum. 97, 093904 (2026)J. D. KalowJ. T. HinchenG. HarrisE. KoukinaD. M. HarringtonP. C. McDanielN. J. BrennanA. GolossanovI. D. SpoolD. ZajacM. MundtS. VarnerM. RussellS. BullK. McCormackD. MayerL. E. KnaianM. KhandakerW. StadolnikW. R. CutlerA. SampatK. LauJ. BetancesC. FaganC. R. ShmaydaM. KochK. PayneN. J. L. MacFaddenJ. SimonK. PetersonA. GamiS. MachavarapuA. TejedaJ. KatzJ. A. AllenR. ChaneyK. KemI. KinitiE. Garcia BadaraccoK. R. LynchP. GandhiC. J. JohnstoneE. NinerC. C. PetitjeanA. AntogniniW. T. ShmaydaS. O. NewburgA. N. Knaian10.1063/5.0337239http://arxiv.org/abs/2510.27592v4Sensor operating point calibration and monitoring of the ALICE Inner Tracking System during LHC Run 32026-09-04T14:05:13ZThe new Inner Tracking System (ITS2) of the ALICE experiment began operation in 2021 with the start of LHC Run 3. Compared to its predecessor, ITS2 offers substantial improvements in pointing resolution, tracking efficiency at low transverse momenta, and readout-rate capabilities. The detector employs silicon Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 26.88$\times$29.24 $μ$m$^2$ and an intrinsic spatial resolution of approximately 5 $μ$m. With a remarkably low material budget of 0.36% of radiation length ($X_{0}$) per layer in the three innermost layers and a total sensitive area of about 10 m$^2$, the ITS2 constitutes the largest-scale application of MAPS technology in a high-energy physics experiment and the first of its kind operated at the LHC. For stable data taking, it is crucial to calibrate different parameters of the detector, such as in-pixel charge thresholds and the masking of noisy pixels. The calibration of 24120 monolithic sensors, comprising a total of 12.6$\times$10$^{9}$ pixels, represents a major operational challenge. This paper presents the methods developed for the calibration of the ITS2 and outlines the strategies for monitoring and dynamically adjusting the detector's key performance parameters over time.2025-10-31T16:18:13ZUpdated pdf according to published version on NIM-ANucl. Instrum. Meth. A 1086 (2026) 171354D. AgguiaroG. Aglieri RinellaL. AgliettaM. AgnelloF. AgneseB. AlessandroG. AlfaroneJ. AlmeE. AnderssenD. AndreouM. AngelettiN. ApadulaP. AtkinsonC. AzzanR. BaccomiA. BadalàA. BalbinoP. BarberisF. BarileL. BarioglioR. BarthelF. BaruffaldiN. K. BeheraI. BelikovA. BenatoM. BenettoniF. BenottoS. BeoleN. BezA. BhattiM. BhopalA. P. BigotG. BocaG. BonomiM. BonoraF. Borotto Dalla VecchiaM. BorriV. BorshchovE. BottaL. BoyntonG. BrowerE. BrunaO. Brunasso CattarelloG. E. BrunoM. D. BucklandS. BufalinoP. CameriniP. CariolaC. Ceballos SanchezM. ChartierJ. ChoS. ChoK. ChoiY. ChoiN. J. ClagueO. A. ClausseF. ColamariaD. ColellaS. ColiA. ColluM. ConcasG. ContinY. Corrales MoralesS. CostanzaJ. B. DaintonE. DanèW. DegrawC. De MartinW. DengG. De RobertisP. DhankherA. Di MauroF. DumitracheD. EliaM. R. ErsdalJ. EumA. FantoniG. FeofilovJ. FerenceiF. FicheraG. FiorenzaA. N. FloresA. FrancoM. FrancoJ. P. FransenD. GajananaA. Galdames PerezC. GaoC. GargiuloL. GarizzoP. GiubilatoM. GoffeA. GrantE. GreckaL. GreinerA. GrelliA. GrimaldiO. S. GroettvikF. GrosaC. Guo HuR. P. HanniganH. HelstrupA. HillH. HillemannsP. HindleyG. HuangM. IannoneJ. P. IddonP. IjzermansM. A. ImhoffA. IsakovJ. JeongT. JohnsonA. JuniqueJ. KaewjaiM. KeilZ. KhabanovaH. KhanH. KimJ. KimJ. KimJ. KimM. KimT. KimJ. KleinC. KobdajA. KotliarovM. J. KraanI. KrálikF. KrizekT. KugathasanC. KuhnP. G. KuijerS. KushpilM. J. KweonM. KwonY. KwonP. La RoccaN. LacalamitaP. LarionovG. LedeyS. LeeT. LeeR. C. LemmonY. LesenechalE. D. LesserB. E. Liang-GilmanF. LibrizziB. LimS. LimS. LindsayA. LiuJ. LiuJ. LiuF. LoddoM. LupiM. MagerA. MaireG. MandaglioV. ManzariC. MarkertG. MarkeyD. MarrasP. MartinengoS. MartiradonnaM. MaseraA. MastroserioG. MazzaD. MazzaroF. MazzaschiM. MazzilliL. McalpineM. MongelliJ. MorantF. MorelP. MorrallV. MucciforaA. MulliriL. MusaA. I. NambrathM. OberggerA. OrlandiA. PalascianoR. PaneroE. PaolettiG. S. PappalardoO. ParasoleJ. ParkL. PassamontiC. PastoreR. N. PatraF. PellegrinoA. PepatoC. PettaS. PianoD. PierluigiS. PisanoM. PĺoskońM. T. PoblockiS. PolitanoE. PrakasaF. PrinoM. ProtsenkoM. PuccioC. PuggioniA. RachevskiL. RamelloM. RasaI. RavasengaA. U. RehmanF. ReidtM. RichterF. RiggiM. RizziK. RøedD. RöhrichF. RonchettiM. J. RossewijA. RossiA. RussoB. Di RuzzaG. SaccàM. SacchettiR. SadikinA. Sanchez GonzalezU. SavinoJ. SchambachF. SchlepperR. SchotterP. J. SecouetM. SelinaS. SenyukovJ. J. SeoR. ShahoyanS. ShaukatF. ShirokopetlevK. SielewiczG. SimantovicM. SittaR. J. M. SnellingsW. SnoeysJ. SongJ. M. SonneveldR. SpijkersA. SturnioloC. P. StylianidisM. ŠuljićD. SunX. SunR. A. SyedA. SzczepankiewiczC. TerrevoliM. ToppiA. TrifiróA. S. TrioloS. TrogoloV. TrubnikovM. TurcatoR. TurrisiT. TveterI. TymchukG. L. UsaiV. ValentinoN. ValleJ. B. Van BeelenJ. W. Van HoorneT. VanatM. Varga-KofaragoA. VelureG. VenierF. VeroneseA. VillaniA. ViticchiéC. WabnitzY. WangP. YangE. R. YeatsZ. YinI. -K. YooJ. H. YoonS. YuanV. ZaccoloA. ZampieriC. ZampolliE. ZhangL. ZhangX. ZhangZ. ZhangV. ZherebchevskiiD. ZhouN. Zurlo10.1016/j.nima.2026.171354http://arxiv.org/abs/2609.04907v1Microkelvin resolution thermometry at the nanometre scale2026-09-04T09:09:42ZAccurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 $μ$K, experimental sensitivities below 50 mK/$\surd \text{Hz}$ and a shot-noise limited sensitivity of 9.6 mK/$\surd \text{Hz}$. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.2026-09-04T09:09:42Z8 pages, 3 figuresJack W. HartSoham PalJulien R. E. RothKatie NinhamAbbie H. AleksandrovaXander PeetroonsSoumen MandalOliver A. WilliamsGavin W. MorleyMete AtatureHelena S. Knowleshttp://arxiv.org/abs/2609.04847v1Dead-zone-free free-induction-decay alkali-metal atomic magnetometer2026-09-04T08:05:32ZThe detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.2026-09-04T08:05:32Z11 pages,8 figures, accepted by PRAX. -K. WangJ. HeH. -H. DengW. GaoD. Shenghttp://arxiv.org/abs/2605.13627v3SINAPSE: A lightweight deep learning framework for accurate and explainable neutron-$γ$ discrimination2026-09-04T07:30:56ZTraditionally, neutron-$γ$ discrimination in organic scintillators relies on techniques such as time-of-flight (ToF) selection and pulse-shape discrimination (PSD). However, particle identification through graphical cuts remains challenging in the low-charge regime due to poor signal-to-noise ratios (SNR). In this work, we propose SINAPSE, a lightweight deep learning framework for accurate and explainable neutron-$γ$ discrimination in the low-charge regime. The framework employs a dual-branch architecture that combines a 1-dimensional convolutional autoencoder for waveform denoising with a classifier for particle identification. Random augmentations are applied to high-SNR waveforms to simulate low-charge conditions, enabling robust extrapolation into regimes where conventional PSD labels are unreliable. We show that SINAPSE achieves superior denoising performance compared to conventional digital signal processing techniques, and outputs well-calibrated probabilities, consistent with traditional graphical cuts. Finally, we apply SHAP (SHapley Additive exPlanations) values to show that model decisions are driven by physically meaningful pulse-shape features, confirming consistency with established PSD principles.2026-05-13T14:53:47Z14 pages, 15 figuresThomas CarreauAdrien MattaOwen SyrettBenoît MaussDavid EtasseCyril LenainPierre MorfouaceJulien TaiebDavid RegnierPatrick CoppMatthew DevlinCharlène SuraultJason Surbrookhttp://arxiv.org/abs/2608.25020v2High-charge collimated and energy-selected laser-driven MeV electron beams produced by magnetic selection2026-09-04T07:13:58ZWe have developed a compact passive energy-selector for MeV-range electrons produced by irradiating solid targets by ultra-intense short-pulse lasers. The device allows for generating electron beams with a variable energy spread over a broad range of energies, from tens of keV to tens of MeV. Here we have demonstrated its use by producing electrons from solid targets in the MeV range and with a ~10% bandwidth, thereby compensating the intrinsic broadband nature of the electrons produced from such source. Coupled with a pulsed magnetic field to further compensate the intrinsic large divergence of this source, it allows to produce a highly-collimated beam of narrow-band and ultra-fast electrons, suitable for a wide range of applications, e.g. radiation therapy or time-resolved electron probing.2026-08-25T18:07:23Z7 pages, 7 figuresI. CohenI. SlabuQ. PeyssonS. DorardY. AbeJ. BéardT. MoraineS. N. ChenA. ChessaK. IidaP. KempskiY. KuramitsuH. KusanoF. NikaidoM. RuszkowskiK. SakaiN. TamakiO. TesileanuJ. Fuchshttp://arxiv.org/abs/2604.19051v2Three-dimensional recoil-electron reconstruction using combined optical imaging and waveform readout for electron-tracking Compton cameras2026-09-04T06:03:31ZAccurate reconstruction of recoil-electron directions is critical for enhancing the point-spread function of electron-tracking Compton cameras (ETCCs) in gamma-ray imaging. Although full three-dimensional (3D) readout systems achieve high-precision reconstruction, they are impractical for large-area detectors because of the enormous data volume. This study proposes and demonstrates a practical alternative for inferring the 3D recoil-electron direction in Compton scattering. This method combines a high-resolution two-dimensional optical image, a one-dimensional waveform signal, and a deep-learning-based method through simulations. The proposed method achieved an angular resolution of approximately $44^\circ$ for the recoil-electron direction in the 40-50 keV range, corresponding to an improvement of a factor of about 1.3 compared with our previous strip-readout approach using pseudo-experimental data generated by Geant4 and MAGBOLTZ simulations for an argon-based gas time projection chamber. In addition, the starting-point resolution of the electron track was improved over the previous method across the 5-50 keV electron energy range. These results demonstrate that complementary information from the transverse image and longitudinal waveform can effectively recover the 3D track topology without requiring full 3D readout. The proposed approach provides a realistic pathway for improving ETCC imaging performance.2026-04-21T03:57:40Z29 pages, 16 figuresTomonori IkedaTatsuya SawanoNaomi TsujiYoshitaka Mizumurahttp://arxiv.org/abs/2609.04734v1Activated carbon-assisted anionic dye decomposition using a dual-liquid post-double dielectric barrier discharge plasma reactor2026-09-04T05:03:53ZNon-thermal Plasma (NTP) technology, including the Dielectric Barrier Discharge (DBD) reactor, has emerged as an effective advanced oxidation process (AOP) for treating persistent organic pollutants in industrial wastewater. Based on this objective, a dual-liquid dielectric-barrier-discharge plasma reactor was built and used to degrade a ternary anionic dye mixture comprising Reactive Red 120, Congo Red, and Methyl Orange in its post-discharge configuration. The adjustable length of the outer liquid electrode (grounded) provides flexibility in controlling the discharge length and cooling, thereby achieving higher degradation efficiency and greater reactor stability. The conducting-liquid high-voltage electrode (a dielectric tube filled with a conductive solution) helps mitigate metal corrosion and oxidation caused by reactive species in the discharge zone. A detailed study of the degradation of ternary anionic dye mixtures (simulated dye wastewater samples) in the presence of activated carbon (AC) was performed to explore the potential applications of post-discharge treatment. The activated carbon (granules) enhances the degradation rate of ternary anionic dye mixtures in basic solutions rather than in acidic or neutral solutions. A comparative study of the degradation reaction kinetics of the ternary anionic dye mixtures in acidic and basic solutions was conducted after analyzing UV-Vis absorption spectra. The role of other parameters, such as solution pH, the mass and size of AC particles, dye concentrations, and AC reuse, was investigated in relation to degradation efficiency. The degradation mechanism was elucidated by the formation of strong oxidizer (hydroxyl radicals) on the surface of activated carbon during post-discharge treatment. However, in acidic or neutral anionic dye solutions, the degradation mechanism was dominated by ozone.2026-09-04T05:03:53ZKrishna V S SuryaMangilal Choudharyhttp://arxiv.org/abs/2512.18769v6Quantitative mobile gamma-ray spectrometry through Bayesian inference2026-09-04T02:10:40ZAccurate quantitative mapping of gamma-ray emitters is critical for applications ranging from radiological emergency response and environmental monitoring to nuclear security and deep space exploration. Here, we show that such mapping can be achieved by combining mobile gamma-ray spectrometry with high-fidelity Monte Carlo simulations and full-spectrum Bayesian inference. Using 6 s of single-pass mobile spectrometry data benchmarked against independent in-situ and laboratory assays, we demonstrate decisive source mixture identification ($>\!\!5σ$), meter-scale source localization, and recovery of source activities with percent-level accuracy. The developed method marks a critical advance in quantitative gamma-ray sensing, enabling improved radiological situational awareness, enhanced terrestrial geophysical and geochemical mapping, as well as more robust constraints on radionuclide abundances on extraterrestrial bodies across the Solar System.2025-12-21T15:17:52Z26 pages, 6 figures, 1 ancillary fileDavid BreitenmoserAlberto StabiliniMalgorzata Magdalena KasprzakSabine Mayerhttp://arxiv.org/abs/2609.05570v1Nanoscale NMR of DNA-Functionalized Diamond Using Individual NV Centers2026-09-04T02:06:55ZNuclear magnetic resonance (NMR) spectroscopy is a powerful probe of molecular structure and dynamics but typically requires large spin ensembles. Here, we demonstrate nanoscale NMR detection of fluorinated DNA using individual near-surface nitrogen-vacancy (NV) centers in diamond nanopillar waveguides under ambient conditions. We covalently tether $^{19}$F-labeled oligonucleotides to mixed nitrogen- and oxygen-terminated surfaces, localizing target spins within the nanoscale sensing volume. Probabilistic spin simulations suggest that the measured signals are consistent with those expected from a few molecules and depend strongly on NV-molecule separation, configuration, and local surface heterogeneity. These results establish a framework for NMR of surface-tethered biomolecules and identify key challenges for single-molecule structural elucidation.2026-09-04T02:06:55Z9 pages, 4 figuresErika JanitzKonstantin HerbLaura A. VölkerChristian L. DegenJohn M. Abendrothhttp://arxiv.org/abs/2609.05557v1Estimating subsurface water mass changes with ground-based gravimetry2026-09-03T17:31:29ZGravitational force is proportional to the mass of an attracting body; therefore, changes in subsurface mass can be detected using gravimetry. In the near subsurface, mass variations are primarily driven by changes in water storage, meaning that gravity measurements provide direct information on variations in water mass. Traditionally, groundwater and soil water dynamics are monitored using point-scale instruments that require direct installation into the subsurface. In contrast, gravimetry is a non-invasive method that integrates signals over a larger spatial extent. Recent advancements in gravimeter technology have significantly improved measurement accuracy and long-term stability under field conditions, thereby expanding their potential for hydrological applications. This review summarizes recent developments in gravimetric instrumentation and provides essential background on gravimeters used for ground-based measurements and their application in hydrology, aiming to facilitate their broader use. In addition, it presents an overview of studies in hydrology and hydrogeology that have successfully applied gravimetry to quantify subsurface water storage changes, estimate hydrological parameters, and constrain numerical models. A perspective on future advancement in gravimetry and resulting potential applications is given.2026-09-03T17:31:29Z30 pages, 6 figures, 3 tablesIsabelle SchmidtJackson Ang'ong'aPeter Bauer-GottweinStephan CostabelChristian FreierBastian LeykaufTina LundgrenMiguel Martinez-DorantesAchim PetersErnst RaselEnrico VogtGregor WillkommenVladimir Schkolnik