https://arxiv.org/api/ATdZRjIk1CcilU2ZgW+juHKyfvA2026-09-10T18:17:23Z248681515http://arxiv.org/abs/2609.08700v1Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope2026-09-08T13:01:33ZDirection-dependent instrumental polarisation is a major systematic limitation in high-fidelity single-dish radio polarimetry, yet a unified characterisation of beam leakage and the conditioning of polarisation recovery is lacking for the Ghana Radio Astronomy Observatory (GRAO) 32-m telescope. We aim to establish a quantitative, direction-dependent polarimetric beam model at 5.0 and 6.7 GHz. High-resolution \texttt{GRASP} electromagnetic simulations of the nominal telescope configuration are used to derive the full complex Jones response and corresponding Mueller matrices, from which beam shape, beam squint, instrumental Stokes leakage, and intrinsic cross-polarisation ratio (IXR) are evaluated across the primary beam. The Stokes $I$ beams have half-power beam widths of $396.4$ and $295.3$ arcsec at 5.0 and 6.7 GHz, respectively, with main-beam efficiencies of $56.4$ and $55.6$ per cent. At 5.0 GHz, the circular-polarisation beam squint is $9.96$ arcsec ($2.5$ per cent of the HPBW), whereas no statistically significant squint is detected at 6.7 GHz. Leakage from Stokes $I$ into linear polarisation remains below $0.1$ per cent within the half-power beam but increases substantially towards the sidelobes. IXR reaches approximately $80$ dB on axis and decreases with angular offset. These results establish the intrinsic electromagnetic polarimetric response of the GRAO 32-m telescope and provide a quantitative baseline for direction-dependent calibration and subsequent observational validation.2026-09-08T13:01:33Z20 pages, 12 figures, 3 tables, accepted to RASTITheophilus Ansah-NarhNia ImaraBenedicta WoodeJoseph Bremang TandohEmmanuel Proven AdzriDiana KlutseEvaristus Uzochukwu Iyidahttp://arxiv.org/abs/2601.08589v2Bridging Theory and Experiment in Virtually Imaged Phased Array (VIPA) Spectrometers2026-09-08T12:45:56ZVirtually imaged phased array (VIPA) spectrometers provide high resolution and fast acquisition in a compact design, but their performance is sensitive to fabrication tolerances, component dimensions, and alignment. Here, leveraging numerical simulations validated by experimental data, we present a framework to identify the parameters that limit VIPA spectrometer resolution. This framework is applied to the construction of a new mid-infrared VIPA spectrometer, tested at wavelengths near $λ$ = 4.6 $μ$m with both continuous-wave and frequency-comb laser sources, with a resolving power predicted by analytical expressions to be as high as $RP$ = 830 000 (corresponding to a resolution of $δν$ = 78 MHz). Validated numerical simulations, however, provided a more realistic estimate that captures limits set by all the optical components. By minimizing aberrations and optimizing alignment, a resolving power of $RP$ = 440 000 ($δν$ = 150 MHz) was experimentally achieved, corresponding to 80 % of the value predicted by numerical simulation of the entire spectrometer. The results bridge the gap between analytical expressions and experimental results for compact, high-resolution VIPA spectrometers to enable more efficient fabrication and advanced design across critical areas like space optics, line-by-line pulse shaping, and broadband spectral sensors.2026-01-13T14:16:04ZKiumars AryanaD. Michelle BaileySolomon I. WoodsAdam J. Fleisherhttp://arxiv.org/abs/2609.08666v1Event-by-Event Space-Charge Gain Suppression in LGADs and Its Impact on Time Resolution2026-09-08T12:31:16ZLow Gain Avalanche Detectors (LGADs) achieve time resolutions below 50 ps through internal charge multiplication, yet the gain is not a fixed device property as the space-charge of the multiplied electron-hole density screens the gain layer field, which suppresses further impact ionization. While TCAD simulations reproduce the average gain suppression, their deterministic treatment of a continuous charge density cannot capture the event-by-event fluctuations that determine the timing performance. We present a Monte Carlo study of space-charge-induced gain suppression in LGADs using the Garfield++ framework, in which the dynamic field of the drifting carriers, computed from a coarse-grained system of charged rings, is superimposed on TCAD-computed static field maps of Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) produced sensors while preserving single carrier avalanche statistics. The simulated gain reproduces published two-photon absorption-transient current technique measurements across two orders of magnitude in injected charge, including the dependence on the injection depth. For minimum ionizing particles, the event-by-event coupling between deposited charge and gain compresses the Landau tail of the multiplied charge, narrowing the signal arrival time distribution and improving the intrinsic time resolution of the HPK-S1 sensor investigated in this work from 53.9 $\pm$ 1.0 ps to 44.5 $\pm$ 0.9 ps. Treating the primary ionization as a stochastic sequence of charge clusters, it is further shown analytically that any gain suppression that decreases with the cluster size narrows the centroid time distribution.2026-09-08T12:31:16ZDjunes JanssensMichael MollHeinrich Schindlerhttp://arxiv.org/abs/2609.08427v1Readout electronics for SUBMET2026-09-08T08:33:54ZA dedicated data acquisition (DAQ) system has been developed for the SUB-Millicharge ExperimenT (SUBMET) at the Japan Proton Accelerator Research Complex (J-PARC), a search for particles carrying a fractional electric charge $Q = εe$ with $ε$ below $\mathcal{O}(10^{-3})$, hereafter referred to as millicharged particles (mCPs). Because such particles are expected to produce at most a few scintillation photons, the system is optimized for single-photoelectron detection from the photomultiplier tubes (PMTs), combining high-speed waveform digitization with precise timing. To capture eight consecutive proton bunches of the 30 GeV J-PARC beam within a single trigger, the eight channels of the Domino Ring Sampler 4 (DRS4) chip are cascaded in groups of four to form two readout inputs, each sampling 4096 points continuously at 820.5 MHz over an effective time window of 5 us. After calibration, timing differences between channels are within 1 ns on the same DRS4 chip, 2 ns on the same board, and 8 ns across different boards, well within the 30 ns coincidence window of the experiment. The front-end electronics achieve an RMS noise below 0.4 mV. The baseline is deliberately offset upward such that the negative-going pulses span a larger fraction of the digitizer range, improving voltage resolution and dynamic range. A trigger control board aggregates data from multiple readout boards and sustains the data-transfer rate required for beam operation. The measured performance confirms that the DAQ system meets the timing, noise, and throughput requirements of the experiment.2026-09-08T08:33:54ZClaudio CampagnariSungwoong ChoSuyong ChoiSeokju ChungMatthew CitronAlbert De RoeckMartin GastalSeungkyu HaAndy HaasChristopher Scott HillInsung HwangHoyong JeongJaebak KimJeonghwa KimHyunki MoonRyan SchmitzDavid StuartEunil WonJae Hyeok YooJinseok YooAyman YoussefAhmad ZaraketHaitham Zarakethttp://arxiv.org/abs/2609.07908v1Solid-state nuclear magnetic resonance search for axion-like dark matter with broadband SQUID magnetometry2026-09-07T19:20:00ZWe report the results of an experimental search for ultralight axion-like dark matter in the mass ranges 19.5--20.5 and 21.5--22 neV. The Cosmic Axion Spin Precession Experiment-electric probes the axion-nuclear electric dipole moment coupling. We perform solid-state nuclear magnetic resonance on $^{207}$Pb spin ensembles which reside in a polarized ferroelectric crystal. The background axion-like dark matter field induces an oscillating torque on the $^{207}$Pb spins via the electric dipole moment coupling $g_{d}$. The experiment is calibrated with pulsed magnetic resonance measurements covering two frequency bands (4.6--5.0 and 5.2--5.3 MHz) that correspond to the axion Compton frequencies associated with the identified axion mass ranges. By sweeping the leading magnetic field applied to the sample, we are able to detect the $^{207}$Pb nuclear magnetic resonance in these frequency ranges using a superconducting quantum interference device, inductively coupled to the sample with a broadband circuit. We establish the upper bounds $|g_{d}| < 4\times 10^{-4}$ GeV$^{-2}$ with 95% confidence in these frequency bands. Our results demonstrate the detection and small-tip angle calibration of low-field $^{207}$Pb nuclear magnetic resonance, allowing for sensitivity to axion-like dark matter in the nanoelectron-volt axion mass range.2026-09-07T19:20:00ZAndrew J. WinterJános ÁdámDeniz AybasDmitry BudkerDerek F. Jackson KimballSurjeet RajendranArne WickenbrockAlexander O. Sushkovhttp://arxiv.org/abs/2609.07722v1Real-time blind indexing by cross-frame consensus2026-09-07T16:34:34ZClassical crystallography determines orientation and unit-cell geometry from a rotation series collected from a single specimen, whereas serial crystallography acquires one still exposure from each of many randomly oriented microcrystals and must reconstruct a complete dataset by pooling partial measurements across the ensemble. In serial experiments, each frame typically contains only a subset of reflections, and frames with few reliable peaks (the small-N regime) are especially difficult to index blindly, because multiple incorrect lattices or orientations can explain sparse observations. The approach implemented in GLINT addresses this small-N regime by treating the dataset, rather than the individual frame, as the unit of inference. Candidate solutions are generated for many frames, weak but recurrent lattice hypotheses are pooled across the ensemble to identify a shared unit cell, and each frame is then registered against that consensus cell through a known-cell orientation search with lower dimensionality than blind indexing. In benchmark tests, GLINT matched the strongest blind indexer in the comparison on indexing yield at roughly 40x lower per-frame blind-indexing latency against XGANDALF's fastest configuration, and batched known-cell registration ran entirely on one GPU, allowing cell discovery on the fly during serial data collection. On experimental serial data, frames indexed blind by GLINT merged to crystallographic quality (CC* = 0.90), while the method rejected non-crystal images rather than forcing unsupported indexing assignments. These results demonstrate that indexing performance can be evaluated not only by indexing yield and throughput, but also by the quality of the resulting merged crystallographic data.2026-09-07T16:34:34Z32 pages including Supporting Information (Secs. S1-S16), 8 figures, 12 tablesStefano MarchesiniYuan Nihttp://arxiv.org/abs/2609.07523v1Reducing simulation-related emissions in rare-event searches through optimised event biasing2026-09-07T14:06:58ZRare-event search experiments continue to extend their sensitivities to unprecedented levels. This requires increasingly small backgrounds, and shielding schemes that can suppress external backgrounds by several orders of magnitude. Moreover, detailed simulations are required to attain a good understanding of these experimental backgrounds. Studies have suggested, however, that simulations and computing-related tasks contribute approximately 10\% to the average particle physicist's carbon footprint. With backgrounds frequently below 0.01 counts per kg of target per keV of energy, simulations require more computing resources; growing a rare-event researcher's computing-related carbon footprint. Event biasing is often applied in shielding simulations as a remedy, yet there is a lack of systematic guidance on how to maximally benefit from them. An optimisation study for the importance-splitting biasing technique is discussed, focused on balancing statistical precision with simulation CPU-time, and how this can benefit the average researcher's carbon footprint.2026-09-07T14:06:58Z5 pages, 1 figure, 1 table. Submitted as proceedings for Sustainable HEP 2026P. KnightsL. J. MilliganK. Nikolopouloshttp://arxiv.org/abs/2609.07385v1Review of Hybrid and Opaque Scintillator Technologies Advancing Neutrino and Dark Matter Detectors2026-09-07T12:00:26ZOrganic liquid scintillators are used since several decades, especially in neutrino physics. They excel at the detection of low-energy particles where energy and timing information is required. Organic liquid scintillators have advantages such as high light yield, radio purity, cost effectiveness, and more. However, they also exhibit disadvantages, most prominently a lack of vertex resolution and particle identification. Various novel ideas have emerged over the course of the last decade to improve the performance of organic liquid scintillators. Among them are most prominently hybrid and opaque scintillators. In this proceedings, these novel scintillators are reviewed and their current applications in the research fields of neutrino and dark matter physics are illustrated.2026-09-07T12:00:26Z8 pages, 2 figures, Proceedings of the International Conference on Technology & Instrumentation in Particle Physics (TIPP 2026)Stefan Schoppmann10.1016/j.nima.2026.172025http://arxiv.org/abs/2609.07378v1Ton-scale Xenon Gas TPC for $0νββ$ Search at Atmospheric Pressure2026-09-07T11:53:23ZWe explore aspects of an unorthodox ton-scale xenon gas time projection chamber detector operated at normal temperature and pressure (NTP), designed for $0νββ$ discovery at $\sim10^{27}$ year sensitivity. At fixed active mass, a greater transparency to $γ$-ray backgrounds and better track clarity exists at NTP relative to higher density. Operation at NTP also alleviates difficulties with pressure containment and significantly reduces HV requirements. With metre-scale electron tracks at a few MeV, event topology can be used to efficiently reject the copious $γ$-ray backgrounds by factors ranging from 550--1200, largely compensating for the greater surface area of the detector. Event topology is captured from anode plane signals combined with sensing the secondary ion component arriving at the cathode plane. A molecular gas additive limits diffusion of the secondary electron tracks to below a cm and provides stable proportional avalanche gain. An energy resolution $δ$E/E $\leq$ 1\% FWHM seems possible. A 100 kg scale demonstrator for this detector technology could lead directly to a ton-scale search.2026-09-07T11:53:23Z38 pages, 10 figuresY. MeiK. MistryD. R. Nygrenhttp://arxiv.org/abs/2606.22607v2Compact VMM3a/SRS integration for high-channel-density TPC readout2026-09-07T11:53:11ZThe HYDRA (HYpernuclei Decay at R$^3$B Apparatus) TPC is a 5,376-channel pion tracker developed for hypernuclear studies at the R$^3$B experiment at GSI/FAIR. Its installation inside the GLAD dipole magnet imposes strict space constraints above the pad plane. To fit the front-end electronics within this volume, the VMM3a/SRS readout was adapted through a vertical hybrid arrangement and custom boards for signal routing and power distribution. At the same time, the readout had to be integrated with the R$^3$B timing system, which is not natively supported by the SRS. This was achieved by recording the R$^3$B heimtime and trigger signals through spare VMM3a channels, allowing the global timestamps to be reconstructed from the same data stream. Simulations of the PCB coupling indicated low crosstalk between adjacent traces, while S-curve measurements gave a baseline noise level consistent with that reported for the standard VMM3a/SRS readout. Cosmic-muon measurements with the plastic wall provided reconstructed tracks and confirmed event-by-event timing correlation between the two detector systems.2026-06-21T17:30:13ZAlexandru EnciuUwe BonnesMeytal DuerPiotr GasikAndrea LagniBastian LöherLeandro Milhomens de FonsecaAlexandre ObertelliMartin PoghosyanHans TörnqvistYanzhao WangFrank Wienholtzhttp://arxiv.org/abs/2609.06407v1Preliminary design of continuous wave Low-Level RF systems for S3FEL2026-09-06T05:55:31ZIn the Shenzhen Superconducting Soft X-ray Free Electron Laser (S3FEL), Continuous Wave (CW) Low-Level Radio Frequency (LLRF) systems perform critical functions including adjusting the power coupling of accelerator cavities, regulating the amplitude and phase of the RF field, and maintaining the resonance frequency and phase of the cavities. These functions are essential to ensure the electron beam operates at the accelerating phase. Within S3FEL, each superconducting cavity is driven by a solid-state amplifier (SSA), with each SSA paired with a dedicated LLRF system. Based on the distinct acceleration cavities employed, the CW LLRF systems for S3FEL are categorized into four types: 1. Primary accelerator LLRF systems (superconducting, 1.3 GHz; quantity: 168), 2. Harmonic cavity LLRF systems (superconducting, 3.9 GHz; quantity: 16), 3. VHF electron gun LLRF systems (room temperature, 216 MHz; quantity: 4), 4. Buncher LLRF systems (room temperature, 1.3 GHz; quantity: 2). These four LLRF system categories exhibit differing requirements for RF field and acceleration cavity control. This report presents the preliminary design schemes for these four types of CW LLRF systems.2026-09-06T05:55:31Z3 pages, 6 figuresZ. Y. ZhangJ. F. ZhuH. L. DingJ. W. HanW. LiJ. Y. YangW. Q. Zhang10.18429/JACoW-SRF2025-THP78http://arxiv.org/abs/2510.06519v2Long wave infrared detection using probabilistic spintronic bolometer arrays2026-09-05T19:46:00ZThe use of probabilistic spintronic devices for infrared radiation detection has introduced a shift in approach to thermal imaging. The integration of probabilistic magnetic tunnel junctions with infrared plasmonic nano-antennas achieves high-sensitivity digital-mode infrared sensors at room temperature. Here, we present a scalable approach towards multipixel plasmonic-spintronic bolometer array fabrication and readout. We fabricate proof-of-concept 2x2 row-column multiplexed probabilistic plasmonic sprintronic arrays and show their response to long-wave infrared radiation (8-14um) with high readout speeds (10K-1M counts per second). These spintronic, ultrafast, nanoscale (SUN) bolometers can result in novel high-pixel density CMOS compatible infrared detection platforms. Our work provides a broadband (9kHz to 3GHz) readout platform for future digital probabilistic detector applications. Furthermore, our approach addresses a key challenge associated with scaling infrared pixel sizes that can drive progress towards high pixel density detector arrays for infrared sensing and microscopy applications.2025-10-07T23:33:33ZUtkarsh SinghLeif BauerAngshuman DekaMohamed MousaDaien HeSakshi GuptaBhagwati PrasadZubin Jacobhttp://arxiv.org/abs/2609.06148v1EBS and in-beam $γ$-ray investigation of FCVA-prepared Cr$_2$O$_3$ targets for low-energy $^{16}$O+$^{16}$O fusion experiments2026-09-05T15:45:22ZThe Cr$_2$O$_3$ solid target for low-energy $^{16}$O+$^{16}$O fusion experiments was fabricated using filtered cathodic vacuum arc (FCVA) deposition. Its composition, oxygen areal density and impurity content were characterized by elastic backscattering spectrometry (EBS), and the impurity-induced background contributions were investigated by in-beam $γ$-ray spectroscopy. EBS results indicate that the Cr$_2$O$_3$ film exhibits good stoichiometry and uniformity, with $^{16}$O areal densities ranging from $(3.24-3.25)\times10^{17}$ atoms/cm$^2$. The EBS analysis reveals a carbon atomic fraction of approximately 1.25-1.29\% in the Cr$_2$O$_3$ layer, while a large amount of carbon impurities are also identified on the surface of Cr substrate. In-beam $γ$-ray spectra reveal prominent transitions associated with $^{27}$Al and $^{24}$Mg at 844, 1015, and 1369 keV, mainly originating from $^{12}$C+$^{16}$O fusion reactions induced by carbon impurities under $^{16}$O irradiation. Meanwhile, characteristic $γ$-rays emissions from evaporation channels of the $^{16}$O+$^{16}$O reaction, including $^{31}$S, $^{31}$P, and $^{28}$Si, were also observed and can be used to extract the $^{16}$O+$^{16}$O fusion cross sections. This work provides an experimental basis for the development of high-purity oxide targets and the optimization of target configurations for future low-background $^{16}$O+$^{16}$O fusion cross section measurements.2026-09-05T15:45:22ZC. WenX. ChenL. WangZ. AnF. BaiY. ChenX. FangY. X. FanB. S. GaoZ. Y. GuoJ. F. HanH. T. HuW. P. LinB. LiaoS. LinG. LiuX. Q. LiuP. P. RenJ. SuJ. H. TanX. D. TangP. WangS. WangD. H. XieN. T. Zhanghttp://arxiv.org/abs/2609.06105v1Simulation Study of the Design and Spatial Resolution of a Novel AC-coupled Cross Strip LGAD2026-09-05T13:57:22ZAC-coupled Low Gain Avalanche Diode (AC-LGAD), evolved from the standard LGAD technology, are silicon detectors characterized by exceptional temporal and spatial resolutions. This work proposes a novel sensor named AC-coupled Cross Strip LGAD (CS-LGAD) structure with dual-layered overlapping strip electrodes. It can achieve two-dimensional particle position measurement with low readout density while also inheriting the high temporal resolution of the LGAD. The sensor structure, doping and current-voltage (I-V) characteristics of the sensor were investigated through TCAD simulations. Additionally, Monte Carlo simulations were employed to simulate the signal response of CS-LGAD to minimum ionizing particles (MIPs). The response of MIPs hitting different positions was simulated, and the reconstruction of particle coordinates (x and y) was achieved based on the sharing of charges on the dual-layer electrodes. The spatial resolution might reach 3.6% and 5.5% of the pitch size in the x and y directions, respectively, according to the simulation. The proposed CS-LGAD is a promising 4D detector with low mass and low readout density.2026-09-05T13:57:22ZJingkang XuMengzhao LiZhiliang HuTianya WuMei ZhaoZhijun LiangLihua MoTianjiao Lianghttp://arxiv.org/abs/2609.06069v1Long-term performance of non-ALD MCP-PMTs in the high-radiation environment of ALICE2026-09-05T12:57:33ZThe Fast Interaction Trigger detector of the ALICE apparatus at the LHC includes a Cherenkov subsystem utilizing 52 Planacon XP85002/FIT-Q microchannel plate-based photomultiplier tubes. It is a precise trigger, multiplicity and luminosity detector located in the forward region, where the flux of collision products is the largest. The photon load reaches up to 2*10^8 photoelectrons / cm^2 / s for the innermost photosensors, corresponding to 0.4 μA / cm^2 average anode current density. The lifetime-extended version of the Planacon MCP-PMT with atomic layer deposition cannot handle such a large anode current. We therefore use the non-ALD version of the Planacons that, on the other hand, suffer from a limited lifetime in terms of the integrated anode charge. Here we present the long-term performance trends of the non-ALD Planacons up to the integrated anode charge of 2 C / cm^2. We demonstrate that the low-gain operation strategy allows to maintain excellent time resolution in multiphoton mode unchanged up to that large integrated charge. While the majority of the equally illuminated MCP-PMTs feature almost identical ageing speed, two outliers suffering from a faster ageing coincide with the outliers in the noise characteristics measured prior to the irradiation. Moreover, we report that the effective ageing speed is partially suppressed by the self-recovery of the response of aged MCP-PMTs newly observed by our group during months-long no-beam periods.2026-09-05T12:57:33ZMaterial of the 12th International workshop on Ring Imaging Cherenkov Detectors (RICH2025) Yury Melikyan for the ALICE Collaboration