https://arxiv.org/api/EVn22VN1pgf3ruHzW5GO122tK2c 2026-03-28T08:57:11Z 24068 0 15 http://arxiv.org/abs/2512.16769v2 Characterisation of silicon photomultipliers in a dilution refrigerator down to 9.4 mK towards a cryogenic cosmic-ray muon veto system 2026-03-26T15:16:34Z We report the characterisation of a FBK NUV-HD-cryo silicon photomultiplier (SiPM) sensor operated in a 9.4 $\pm$ 0.2 mK environment inside a dilution refrigerator, towards the development of a cryogenic cosmic ray muon veto system to be operated internal to a dilution refrigerator required for low background experiments such as the QUEST-DMC dark matter search experiment. We characterise the single photon response and the gain (the charge produced per detected photon), the dark count noise rate, and correlated noise contributions as a function of operating voltage. This paper also reports first proof-of-concept measurements of using a SiPM coupled to scintillator internal to a dilution refrigerator, towards detecting high-energy events consistent with candidate cosmic-ray muon signals. 2025-12-18T17:02:51Z QUEST-DMC Collaboration : A. Kemp S. Autti E. Bloomfield A. Casey N. Darvishi D. Doling N. Eng P. Franchini R. P. Haley P. J. Heikkinen A. Jennings S. Koulosousas E. Leason L. V. Levitin J. March-Russell A. Mayer J. Monroe D. Münstermann M. T. Noble J. R. Prance X. Rojas T. Salmon J. Saunders J. Smirnov R. Smith M. D. Thompson A. Thomson A. Ting V. Tsepelin S. M. West L. Whitehead D. E. Zmeev http://arxiv.org/abs/2603.25478v1 Cryogenic operation of neutron-irradiated silicon photomultiplier arrays up to 1e14 neq/cm^2 2026-03-26T14:18:32Z In the context of the Scintillating Fibre (SciFi) Tracker for the LHCb Upgrade 2, radiation-induced damage in silicon photomultipliers (SiPMs) has been studied over a wide temperature range, from room temperature down to 100 K. With the LHCb detector Upgrade 1, installed during the LHC's Long Shutdown 2 (LS2) (2019-2021), the first large-scale SciFi tracker read out by multichannel silicon photomultipliers (SiPMs) was constructed, installed, and has been operated ever since. A major challenge for the SciFi tracker is the neutron radiation at the SiPMs' location. At the end of the lifetime of the Upgrade 1 detector, the expected neutron fluence for the SiPMs will reach 6e11 neq/cm^2. Cryogenic operation is being investigated to mitigate even higher radiation-induced damage for Upgrade 2, where the total neutron fluence is expected to reach 3e12 neq/cm^2. A large set of custom SiPM arrays, varying in pixel size, electric field configuration, and doping implant concentration, developed by FBK and Hamamatsu, were tested after neutron irradiation. Characterisation was performed in a dedicated cryogenic test setup, where the operating temperature was varied over a wide range. Key performance parameters such as breakdown voltage, gain, dark count rate, optical crosstalk, and afterpulsing were characterised as functions of temperature, overvoltage, and neutron fluence. The result is a precise assessment of radiation damage for state-of-the-art technology from two leading SiPM manufacturers, allowing the results to be transferred to other SiPM applications. 2026-03-26T14:18:32Z Submitted to IEEE Transactions on Nuclear Science. 8 pages, 17 figures Esteban Currás-Rivera Guido Haefeli Federico Ronchetti http://arxiv.org/abs/2603.23540v2 An Improved Paralyzable Detector Model 2026-03-26T14:14:18Z Certain radiation detectors are 'paralyzed' with high input count rates. When applied to count rates close to the event discriminator working rate the one-parameter dead time model fails. Here we present a corrected paralyzable detector model accounting for the event discriminator's finite response time. This two-parameter analytical model, when compared to the experimental data from a commercial x-ray detector, gives an improved description of the input and output count rate relations. Furthermore, it can independently determine the discriminator response time and the pulse shaper dead time, critical parameters for understanding a detector's performance. Finally, this model also provides a post-acquisition pile-up correction that greatly reduces artifacts in high-throughput spectra. In some situations, applying this model to optimize the acquisition and post-acquisition correction allows a user to acquire data an order of magnitude faster without compromising accuracy. 2026-03-13T04:57:39Z 9 pages, 9 figures Yueyun Chen Matthew Mecklenburg http://arxiv.org/abs/2603.25436v1 Real-Time Wiener Deconvolution for feature reconstruction in JUNO 2026-03-26T13:29:02Z In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics. 2026-03-26T13:29:02Z L. Lastrucci M. Grassi A. Triossi J. Hu X. Jiang R. Brugnera A. Garfagnini V. Cerrone L. V. D'Auria A. Gavrikov R. M. Guizzetti A. Serafini G. Andronico V. Antonelli A. Barresi D. Basilico M. Beretta A. Bergnoli M. Borghesi A. Brigatti R. Bruno A. Budano B. Caccianiga A. Cammi R. Caruso D. Chiesa C. Clementi C. Coletta S. Dusini A. Fabbri G. Felici G. Ferrante M. G. Giammarchi N. Giudice N. Guardone F. Houria A. Islam C. Landini I. Lippi L. Loi P. Lombardi F. Mantovani S. M. Mari A. Martini L. Miramonti M. Montuschi M. Nastasi D. Orestano F. Ortica A. Paoloni L. Pelicci E. Percalli F. Petrucci E. Previtali G. Ranucci A. C. Re B. Ricci A. Romani C. Sirignano M. Sisti L. Stanco E. Stanescu Farilla V. Strati M. D. C. Torri C. Tuvè C. Venettacci G. Verde L. Votano G. Dong J. Dong L. Fan S. Hou Z. Ning Y. Sun Y. Wang Z. Wang X. Yan http://arxiv.org/abs/2512.20678v2 Synchromodulametry: From Coincidence Detection to Coherent State Measurement 2026-03-26T12:38:27Z Distributed sensor networks are commonly operated through coincidence logic: if detector reports overlap within a prescribed time window, an event is declared. While effective for clean, high-significance signals, this approach becomes fragile when detector liveness is intermittent due to deadtime, saturation, vetoes, resets, or asynchronous sampling. In such settings, physically meaningful events may be partially observed yet discarded by binary coincidence rules. We introduce \textit{Synchromodulametry}, a hardware-first framework that promotes \emph{coherence} -- rather than coincidence alone -- to a real-time state variable of the network. The framework is organized around three compact components: a liveness-aware effective observable $Ψ_i^{\mathrm{eff}}(t)$ that preserves information continuity under detector non-idealities, an alignment layer based on relative inter-node delays $τ_{ij}$, and a covariance-based coherence functional $\mathcal{G}(t)$ for triggering and monitoring. Together, these components define a practical pipeline from raw digitized streams to persistent observables, aligned network state, and global coherence estimation. Rather than reducing detector behavior to a binary coincidence flag, Synchromodulametry represents the network as a system capable of entering, maintaining, and losing coherent state in real time. 2025-12-21T19:16:25Z Methods and instrumentation framework paper Thammarat Yawisit http://arxiv.org/abs/2603.23541v2 Indirect monitoring of fast-charge cycling behavior of an energy-storage device-analysis of ambient temperature variations 2026-03-26T09:11:14Z I present a reanalysis of temperature data from a publicly available certified laboratory report that documented the self-discharging behavior of an energy-storage device during 10 days. Graphs of temperature variations of both the tested device itself and the test chamber (fume hood) were given mainly for monitoring without further analysis, and variations in the ambient temperature signal were attributed to "other cells being cycled simultaneously in the same fume hood". I show that the ambient temperature signal alone -- together with some quite mild and reasonable assumptions -- allow to extract previously unpublished information on the simultaneously run test on the other cells: 1) the number of charge/discharge cycles 2) the cycle period, 3) the charge/discharge half-cycle asymmetry, and -- most significantly -- evidence that 4) the mentioned "other device" completed 338 full charge/discharge cycles at 3C rate at room temperature without any detectable thermal degradation signature. 2026-03-13T09:13:15Z 15 pages, 4 figures, reanalysis of published test data Pertti O. Tikkanen http://arxiv.org/abs/2603.10449v3 Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control 2026-03-26T07:32:24Z Two Fresnel zone plates zooming optics have been successfully developed and installed at the AR-NE1A beamline of the Photon Factory at the high energy accelerator research organization (KEK) in Japan. To ensure the reliable and versatile operation of this optical instrumentation, a dedicated control architecture has been implemented based on the simple transmission and retrieval system (STARS) framework, incorporating the newly proposed STARS common commands for detector control (CCDC) -- a detector-specific data acquisition (DAQ) state and command system. This system serves as both a practical control system for zooming optics and a demonstration model for modular extensibility using the STARS framework and inter-operability among detector systems enabled by the CCDC command set. The system has been commissioned, and its performance has been verified at the AR NE1A beamline. The control architecture affords enhanced configurational flexibility for optical components and provides an interface appropriate for both routine users and advanced experimental protocols. 2026-03-11T06:07:02Z Preprint of full-length article for Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier Ryutaro Nishimura Yuki Shibazaki Daisuke Wakabayashi Yoshio Suzuki Keiichi Hirano Hiroaki Nitani Takashi Kosuge Noriyuki Igarashi http://arxiv.org/abs/2603.09461v2 Recent application studies of an INTPIX4NA SOIPIX detector-based X-ray camera using an SiTCP-XG 10GbE-based high-speed readout system at KEK facilities 2026-03-26T07:27:47Z The Silicon-On-Insulator PIXel (SOIPIX) detector is a unique monolithic structure imaging device currently being by the SOIPIX group, led by the High Energy Accelerator Research Organization (KEK). Our detector team at the KEK Photon Factory (PF) has developed an X-ray camera based on the INTPIX4NA SOIPIX detector. This detector provides a sensitive area of 14.1 $\times$ 8.7 $\mathrm{mm^2}$, with 425,984 pixels arranged in an 832-column $\times$ 512-row matrix and a pixel size of 17 $\times$ 17 $\mathrm{μm^{2}}$, and offers high spatial resolution and excellent sensitivity under low intensity X ray conditions. The readout system used in the X-ray camera is developed at the PF. It is equipped with SiTCP-XG, a 10 Gb Ethernet network controller implemented on a field-programmable gate array, enabling high-frame-rate imaging at several hundred hertz. We are currently investigating the applicability of this X-ray camera in several experiments at KEK. Herein, we report three recent application studies: (1) application to the optics of an X-ray zooming microscope using two Fresnel zone plates at PF AR-NE1A; (2) application to a phase-contrast X-ray imaging system using a two-crystal X-ray interferometer at the PF BL-14C beamline; and (3) application to nondestructive detection of lithium in Li-ion battery electrode materials using muonic X-rays at J-PARC MLF Muon D2. 2026-03-10T10:14:28Z A preprint of proceedings for the 14th international "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD-14) which was held on November 16 - 21, 2025 at the Activity center of Academia Sinica, Taipei, Taiwan Ryutaro Nishimura Noriyuki Igarashi Daisuke Wakabayashi Yuki Shibazaki Yoshio Suzuki Keiichi Hirano Hiromi Miki Akio Yoneyama Hiroshi Sugiyama Kazuyuki Hyodo Izumi Umegaki Koichiro Shimomura Yasuo Arai http://arxiv.org/abs/2603.25085v1 Beam Test Characterization of Silicon Microstrip Detector Flight-Model Ladders for the AMS-02 Upgrade 2026-03-26T06:38:59Z The AMS-02 experiment plans to install a new silicon microstrip tracker layer (Layer-0) on top of the existing detector, increasing the cosmic-ray acceptance by a factor of 3. Layer-0 employs a design in which multiple silicon microstrip detectors (SSDs) are connected in series to form long detector ladders. We present a detailed performance study of the flight-model ladders using a 350~GeV mixed hadron beam at the CERN SPS. The study focuses on the following aspects: (i) the performance of ladders with different numbers of SSDs, for which the intrinsic spatial resolution at normal incidence varies from $9.5~μ\mathrm{m}$ to $11.4~μ\mathrm{m}$ for ladders composed of 8 to 12 SSDs; (ii) the response consistency for particles impacting on the \emph{Head} and \emph{Tail} regions of the ladder; and (iii) the dependence of the detector performance on the particle incidence angle. 2026-03-26T06:38:59Z Dexing Miao Giovanni Ambrosi Mattia Barbanera Baasansuren Batsukh Hengyi Cai Mengke Cai Xudong Cai Yuman Cai Yuan-Hann Chang Shanzhen Chen Hsin-Yi Chou Xingzhu Cui Mingyi Dong Matteo Duranti Ke Gong Mingjie Feng Valerio Formato Yisheng Fu Daojin Hong Maria Ionica Xiaojie Jiang Yaozu Jiang Liangchenglong Jin Shengjie Jin Vladimir Koutsenko Qinze Li Tiange Li Zuhao Li Chih-Hsun Lin Changcheng Liu Cong Liu Hanbing Liu Pingcheng Liu Alberto Oliva Ji Peng Wenxi Peng Rui Qiao Shuqi Sheng Tianyu Shi Gianluigi Silvestre Zetong Sun Congcong Wang Feng Wang Hongbo Wang Zhijie Wang Zibing Wu Zhiyu Xiang Suyu Xiao Weiwei Xu Zixuan Yan Haotian Yang Sheng Yang Yuhang You Xuhao Yuan Yuan Yuan Fengze Zhang Xiyuan Zhang Zijun Xu Jianchun Wang http://arxiv.org/abs/2603.25080v1 A Telescope System for Charge and Position Measurement of High Energy Nuclei 2026-03-26T06:29:17Z A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance was validated through a heavy ion beam test at the CERN SPS. A hybrid machine learning algorithm is proposed to address the challenges of nuclear charge measurement with SSDs. The system achieves a spatial resolution of $\mathcal{O}(1) \,$\SI{}{\micro\metre} and a charge resolution better than 0.16 charge units for nuclei from $Z = 1$ to $Z = 29$, with a sensitive area of $8 \times 8 \, \mathrm{cm}^2$. To the best of our knowledge, this represents the most precise charge and spatial resolution simultaneously achieved by a silicon telescope to date. 2026-03-26T06:29:17Z Dexing Miao Zhiyu Xiang Giovanni Ambrosi Mattia Barbanera Baasansuren Batsukh Mengke Cai Xudong Cai Yuan-Hann Chang Shanzhen Chen Hsin-Yi Chou Xingzhu Cui Mingyi Dong Matteo Duranti Ke Gong Mingjie Feng Valerio Formato Daojin Hong Maria Ionica Xiaojie Jiang Yaozu Jiang Liangchenglong Jin Shengjie Jin Vladimir Koutsenko Tiange Li Zuhao Li Chih-Hsun Lin Cong Liu Pingcheng Liu Xingjian Lv Alberto Oliva Ji Peng Wenxi Peng Rui Qiao Shuqi Sheng Gianluigi Silvestre Congcong Wang Feng Wang Hongbo Wang Zibing Wu Suyu Xiao Weiwei Xu Sheng Yang Xuhao Yuan Xiyuan Zhang Zijun Xu Jianchun Wang http://arxiv.org/abs/2603.25078v1 Development of a one-dimensional position sensitive detector for Compton X-ray polarimeters 2026-03-26T06:25:32Z The scientific potential of X-ray polarimetry has long been recognized, but the challenges in measuring polarization have left it largely unexplored, particularly in the hard X-ray regime. While tremendous advancement has been made in soft X-ray polarimetery, the lack of sensitive hard X-ray polarimeters and polarisation measurements continues to limit our understanding of high-energy astrophysical processes. With the development of hard X-ray mirrors, it is now possible to develop a sensitive focal plane hard X-ray polarimeter. One such effort is CXPOL, a prototype developed at PRL, India, which consists of a plastic scintillator as active scatterer readout by PMT surrounded by CsI(Tl) scintillators in cylindrical array with SiPM readout from one side. First results of the prototype have been demonstrated in 20 to 80 keV energy range. The sensitivity of the instrument can be significantly enhanced using faster and better light yield scintillator like NaI as absorbers. Further, the use of a position-sensitive scatterer and absorbers, can also provide spectroscopic information by measuring the interaction position along the length and from the known energy depositions in the detectors. Position sensitive detectors are also helpful in mitigating the systematic effects introduced by the off-axis events in the polarisation measurements. Here, we demonstrate the detection sensitivity in the 100x20x5 mm^3 NaI(Tl) scintillator absorber readout on both ends by SiPM arrays operating in co-incidence. In this work, we characterize the first prototype of this detector system and investigate the variation in energy and position resolution, and light output with irradiation position along the length of the detector. The two end readout in co-incidence also reduces the overall SiPM background per absorber by an order of magnitude, further enhancing the polarimetric sensitivity of the instrument. 2026-03-26T06:25:32Z 18 pages, 12 figures, Accepted for publication in Experimental Astronomy (2026) Abhay Kumar Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India INAF Istituto di Astrofisica e Planetologia Spaziali di Roma, Via Fosso del Cavaliere 100, Roma, Italy Santosh V. Vadawale Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India N. P. S. Mithun Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India Tanmoy Chattopadhyay Kavli Institute of Particle Astrophysics and Cosmology, Stanford University, Stanford, CA, USA S. K. Goyal Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India A. R. Patel Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India M. Shanmugam Physical Research Laboratory, Astronomy & Astrophysics Division, Ahmedabad, India http://arxiv.org/abs/2602.17126v2 Measurement of ionization yield of low energy ions in low pressure $\mathrm{CF}_{4}$ gas for dark matter searches 2026-03-26T00:45:22Z Direction-sensitive direct dark matter search experiments have been conducted using gaseous detectors. In spite of the long history of the study on the energy deposition of charged particles in materials, a full agreement between the measured results and theoretical predictions, especially in a low energy scale, are yet to be achieved. It is thus important to measure the ionization yields of recoil nuclei for the experiments with gaseous detectors using an ionization charge readout scheme. This study measured the ionization yield using a low-energy ion beam facility at Kanagawa University. The ionization yields for fluorine ions with an energy range of 5 $\sim$ 50 keV were measured using a dedicated proportional wire chamber filled with $\mathrm{CF}_{4}$ gas at 0.06 atm. The low-energy ion injection scheme into a gaseous detector was established and the ionization yield for fluorine ions was obtained to be 0.45 at 30 keV with a moderate dependence on the ion energy. 2026-02-19T06:55:50Z 10 pages, 8 figures, submitted to JINST Satoshi Higashino Wakako Toyama Takuya Shiraishi Yasushi Hoshino Tatsuhiro Naka Kentaro Miuchi http://arxiv.org/abs/2603.24781v1 PySiPMGUI: A Universal Python-Based Software for Photodetector I-V Quality Assurance: From Underground Dark Matter Searches to Astroparticle Cherenkov Cameras 2026-03-25T19:52:27Z Silicon photomultipliers (SiPMs) are currently the most prevalent photon detection technology in modern experiments in high-energy physics, astroparticle physics, neutrino physics, and dark matter searches. The high detection efficiency for photons, excellent timing resolution, small size, and magnetic field independence make them ideal for precision measurements in low-light conditions. However, key parameters like breakdown voltage, gain, and dark count rate show a strong dependence on the bias voltage and temperature, requiring a systematic characterization. In this work, we present an open-source graphical user interface (GUI) for automated SiPM characterization, leveraging PyVISA-controlled instruments. The tool provides a free, open, and platform-independent solution for detector R&D and large-scale SiPM characterization. 2026-03-25T19:52:27Z Tanay Dey Suraj Shaw Ritabrata Banerjee Pratik Majumdar Satyaki Bhattacharya http://arxiv.org/abs/2508.03537v2 The High Level Trigger and Express Data Production at STAR 2026-03-25T17:21:23Z To meet the demands of the Beam Energy Scan phase-II (BES-II) program, the STAR experiment at RHIC developed a dual real-time framework consisting of a High Level Trigger (HLT) and an Express Data Production system (xProduction). The HLT operates online within the Data Acquisition (DAQ) chain on a multicore CPU cluster, with optional acceleration using Xeon Phi coprocessors. It employs parallelized algorithms, such as the Cellular Automaton track finder, for fast tracking, vertexing, and event filtering, enabling real-time event selection and detector monitoring. In parallel, xProduction runs independently of the DAQ loop and performs near offline-quality calibration and reconstruction within hours. Using the express data stream, enhanced by HLT selections, and the STAR calibration framework, it enables early physics analysis and provides collaboration-wide access to analysis-ready datasets. Together, HLT and xProduction form a complementary system combining real-time selection with rapid high-quality reconstruction. This framework has enabled prompt reconstruction of the ${}^5_Λ\mathrm{He}$ hypernucleus and efficient processing of large datasets, demonstrating scalability for future high-luminosity experiments. 2025-08-05T15:05:34Z 14 figures, 2 tables NIMA Volume 1088, August 2026, 171489 Wayne Betts Jinhui Chen Yuri Fisyak Hongwei Ke Ivan Kisel Pavel Kisel Grigory Kozlov Jeffery Landgraf Jerome Lauret Tonko Ljubicic Yugang Ma Spyridon Margetis Hao Qiu Diyu Shen Qiye Shou Xiangming Sun Aihong Tang Gene Van Buren Iouri Vassiliev Baoshan Xi Zhenyu Ye Zhengqiao Zhang Maksym Zyzak http://arxiv.org/abs/2603.24645v1 Global detector network to search for high-frequency gravitational waves (GravNet): conceptual design 2026-03-25T16:28:27Z We propose GravNet (Global detector network to search for high-frequency gravitational waves), a novel experimental scheme enabling the search for gravitational waves in the MHz to GHz frequency range. Such high-frequency gravitational waves could arise from a variety of phenomena connected to some of the most pressing and fundamental questions in modern cosmology. The GravNet concept is based on synchronous measurements of signals from multiple experimental measurement devices operating at geographically separated locations. While gravitational-wave-induced signatures may be present in the signal of a single detector, distinguishing them from instrumental or environmental noise is highly challenging. By analyzing correlations between signals from several distant detectors, the detection significance is substantially enhanced, while simultaneously enabling studies of the nature and origin of the gravitational-wave signal. In this work, we discuss the GravNet concept specifically in the context of cavities operated in strong magnetic fields, as these currently represent the most technically mature and experimentally advanced realization of the scheme. As part of this proposal, a first demonstration experiment using a non-superconducting cavity has been performed, providing the basis for the data-analysis strategies discussed in this work. Finally, we outline the prospects and future development of GravNet as a global network for high-frequency gravitational-wave searches. 2026-03-25T16:28:27Z 25 pages, 10 figures Dorian Amaral Diego Blas Yuliia Borysenkova Dmitry Budker Alessandro D'Elia Giorgio Dho Alejandro Díaz-Morcillo Daniele Di Gioacchino Sebastian Ellis Claudio Gatti Benito Gimeno Jordan Gué Stefan Horodenski Saarik Kalia Younggeun Kim Tom Krokotsch Tomas Kvietkauskas Adrián Lambíes-Asensio Carlo Ligi Giovanni Maccarrone Giovanni Mazzitelli Juan Monzó-Cabrera José R. Navarro-Madrid José Reina-Valero Alessio Rettaroli Kristof Schmieden Tim Schneemann Matthias Schott Simone Tocci Sandro Tomassini Oleg Tretiak Luca Visinelli Changhao Xu