https://arxiv.org/api/kGk3/GKEw7U/SN+0aLng44ek3PI2026-04-14T12:42:36Z874554015http://arxiv.org/abs/2507.06936v13D atomic structure determination with ultrashort-pulse MeV electron diffraction2025-07-09T15:16:48ZUnderstanding structure at the atomic scale is fundamental for the development of materials with improved properties. Compared to other probes providing atomic resolution, electrons offer the strongest interaction in combination with minimal radiation damage. Here, we report the successful implementation of MeV electron diffraction for ab initio 3D structure determination at atomic resolution. Using ultrashort electron pulses from the REGAE accelerator, we obtained high-quality diffraction data from muscovite and $1T-TaS_2$, enabling structure refinements according to the dynamical scattering theory and the accurate determination of hydrogen atom positions. The increased penetration depth of MeV electrons allows for structure determination from samples significantly thicker than those typically applicable in electron diffraction. These findings establish MeV electron diffraction as a viable approach for investigating a broad range of materials, including nanostructures and radiation-sensitive compounds, and open up new opportunities for in-situ and time-resolved experiments.2025-07-09T15:16:48Z44 pages, 4 (plus 12 supplementary) figures, 8 supplementary tables; High-energy MeV electron diffraction enables structure determinations from considerably thicker samples than currently possibleVincent HennickeCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyMax HachmannDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyPaul Benjamin KlarFaculty of Geosciences and MAPEX Center for Materials and Processes, University of Bremen, Bremen, GermanyPatrick Y. A. ReinkeCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyTim PakendorfCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyJan MeyerCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyHossein Delsim-HashemiDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyMiriam BarthelmessCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanySreevidya Thekku VeeduCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyPontus FischerCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyAna C. RodriguesCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyArlinda QelajDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyJuna WernsmannDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyFrancois LemeryDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanySebastian GüntherCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanySven FalkeCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyErik FröjdPaul-Scherrer Institut, Villigen, SwitzerlandAldo MozzanicaPaul-Scherrer Institut, Villigen, SwitzerlandLukas PalatinusInstitute of Physics of the Czech Academy of Sciences, Prague, CzechiaKai RossnagelInstitut für Experimentelle und Angewandte Physik, Christian-Albrechts-Universität zu Kiel, Kiel, GermanyRuprecht Haensel Laboratory, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyBernd SchmittPaul-Scherrer Institut, Villigen, SwitzerlandHenry N. ChapmanCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, GermanyThe Hamburg Centre for Ultrafast Imaging, Hamburg, GermanyDepartment of Physics, University of Hamburg, Hamburg, GermanyWim LeemansDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyKlaus FlöttmannDeutsches Elektronen-Synchrotron DESY, Hamburg, GermanyAlke MeentsCenter for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Hamburg, Germanyhttp://arxiv.org/abs/2507.06420v1Equivalent circuit modelling as a design tool for particle accelerator RF components2025-07-08T21:56:46ZThis paper presents a comprehensive approach to generating and utilizing accurate equivalent circuits for structures commonly found in the particle accelerator domain. After a discussion of equivalent circuits in general, a systematic process for determining the appropriate circuit topology is outlined, and a method for finding circuit element values is introduced. The proposed methodology is demonstrated in detail, supported by four illustrative examples. Equivalent circuit element values are provided. An example of a decomposition strategy for handling complex structures is given. Additionally, a list of typical applications of equivalent circuits is provided with brief descriptions.2025-07-08T21:56:46Z20 pages, 19 figures, submitted to Physical Review Accelerators and BeamsDieter PelzMark Bolandhttp://arxiv.org/abs/2507.06403v1Ultra-high-gain water-window X-ray laser driven by plasma photocathode wakefield acceleration2025-07-08T21:10:26ZX-ray free-electron lasers are large and complex machines, limited by electron beam brightness. Here we show through start-to-end simulations how to realise compact, robust and tunable X-ray lasers in the water window, based on ultra-bright electron beams from plasma wakefield accelerators. First, an ultra-low-emittance electron beam is released by a plasma photocathode in a metre-scale plasma wakefield accelerator. By tuning the beam charge, space-charge forces create a balance between beam fields and wakefields that reduces beam energy spread and improves energy stability - both critical for beam extraction, transport, and focusing into a metre-scale undulator. Here, the resulting ultra-bright beams produce wavelength-tunable, coherent, femtosecond scale photon pulses at ultra-high gain. This regime enables reliable generation of millijoule-gigawatt-class X-ray laser pulses across the water window, offering tunability via the witness beam charge and robustness against variations in plasma wakefield strength. Our findings help democratise access to coherent, high-power, soft X-ray radiation.2025-07-08T21:10:26Z32 pages, 9 figuresLily H. A. BermanDavid CampbellEdgar HartmannThomas HeinemannThomas WilsonBernhard HiddingAhmad Fahim Habibhttp://arxiv.org/abs/2507.05436v1Design and Numerical Simulation of a SARA-Based RF Accelerator Using the $\mathrm{TE}_{112}$ Mode2025-07-07T19:38:03ZCharged particle accelerators play a pivotal role in scientific research, industry, and medical applications. Among them, radiofrequency (RF) accelerators offer a promising approach for achieving high-energy particle acceleration in compact systems. This study presents the design and numerical simulation of a microwave-driven electron accelerator based on the Spatial Autoresonant Acceleration (SARA) mechanism. The proposed system consists of a cylindrical resonant cavity excited in the TE$_{112}$ mode, influenced by a tailored magnetostatic field generated by a set of external coils. The electromagnetic field distribution, magnetostatic configuration, and electron dynamics were simulated using COMSOL Multiphysics. The results validate the feasibility of accelerating electrons to energies close to 200~keV with a 1~kW microwave source, demonstrating their capability for X-ray generation through Bremsstrahlung radiation. Additionally, the study provides optimized design parameters for practical implementation. The high-quality factor $(Q\sim25000)$ of the resonant cavity ensures efficient energy storage but necessitates precise frequency control to maintain resonance conditions. The findings underscore the potential of SARA-based accelerators for compact X-ray sources, with applications in medical imaging, security screening, and materials analysis.2025-07-07T19:38:03ZTomás A. CarreñoJesús E. LópezYerson F. BarraganCarlos J. Páez-GonzálezEduardo A. Orozcohttp://arxiv.org/abs/2503.10820v2A New Method for Wavefront Sensing using Optical Masking Interferometry2025-07-07T16:45:13ZWave front sensing of the surface of equal phase for a propagating electromagnetic wave is a vital technology in fields ranging from real time adaptive optics, to high accuracy metrology, to medical optometry. We have developed a new method of wavefront sensing that makes a direct measurement of the electromagnetic phase distribution, or path-length delay, across an optical wavefront. The method is based on techniques developed in radio astronomical interferometric imaging. The method employs optical interferometry using a 2-D aperture mask, a Fourier transform of the interferogram to derive interferometric visibilities, and self-calibration of the complex visibilities to derive the voltage amplitude and phase gains at each hole in the mask, corresponding to corrections for non-uniform illumination and wavefront distortions across the aperture, respectively. The derived self-calibration gain phases are linearly proportional to the electromagnetic path-length distribution to each hole in the aperture mask, relative to the path-length to the reference hole, and hence represent a wavefront sensor with a precision of a small fraction of a wavelength. The method was tested at $λ=400\,$nm at the Xanadu optical bench at the ALBA synchrotron light source using a rotating mirror to insert tip-tilt changes in the wavefront. We reproduce the wavefront tilts to within $0.1''$ ($5\times 10^{-7}$~radians). We also derive the static metrology though the optical system for non-planar wavefront distortions to $\sim \pm1$~nm repeatability. Lastly, we derive frame-to-frame variations of the wavefront tilt due to vibrations of the optical components which range up to $\sim 0.5"$. These variations are relevant to adaptive optics applications. Based on the measured visibility phase noise after self-calibration, we estimate an rms path-length precision per 1~ms exposure of 0.6 nm.2025-03-13T19:11:23Z9 figures, 15 pages, for SPIE Proceedings 13619-41 Unconventional Imaging, Sensing and Adaptive OpticsProceedings Volume 13619, Unconventional Imaging, Sensing, and Adaptive Optics 2025; 136190V (2025)C. L. CarilliNRAOL. TorinoALBA-CELLSB. NikolicCavendish AstrophysicsN. ThyagarajanCSIROU. IrisoALBA-CELLS10.1117/12.3062598http://arxiv.org/abs/2408.01954v3Simulation studies on compensation for incoherent magnet error driven half-integer and 3rd-order resonances with space charge in HIAF-BRing2025-07-07T06:52:01ZMagnet error driven resonances under space-charge-induced resonance crossing represents a significant limitation on beam intensity in low-injection-energy high-intensity synchrotrons. Unstable particle motion arises from the combined effects of space-charge-induced tune spread and magnetic field imperfections, which limits the intensity. This paper introduces a space-charge-Twiss modification to the Resonance Driving Terms (RDTs). The new RDTs are named modified RDTs. Modified RDTs aim to describe the nonlinear behavior under incoherent error driven resonances induced by the combined effect of space charge and magnetic field imperfections. The feasibility of the compensation scheme with modified RDTs is demonstrated through coasting-beam simulations under space-charge-induced half-integer and 3rd-order resonances, using the lattice of the High Intensity Heavy-Ion Accelerator Facility Booster Ring (HIAF-BRing). The simulations demonstrate that the compensation through minimizing modified RDTs significantly suppresses the emittance growth and the unstable particle motion. Besides, the effect of compensation scheme with modified RDTs against periodical resonance crossing is evaluated in bunched-beam simulations.2024-08-04T08:05:03ZCheng GuoJie LiuJiancheng YangRuihu Zhuhttp://arxiv.org/abs/2109.14273v3Scale invariance of electrodynamics in radio-frequency linear accelerators2025-07-04T06:45:55ZThis study discusses the scale transformation of electromagnetic fields and trajectories of ions in radio-frequency linear accelerators. We will obtain a condition for mechanical similarity, where Maxwell equations with source terms and the equation of motion under Lorentz force remain invariant, including space charge fields, while the trajectories of ions are accordingly scaled. The possibility of linear accelerators for extremely high current beams will be considered based on this condition.2021-09-29T08:38:14ZREVTeX 4.1, 5 pages, no figure, Corrected typos. Revised argument in section V, results unchanged. Appendix addedOsamu Kamigaitohttp://arxiv.org/abs/2507.03333v1Aperture limitation localization using beam position and beam loss monitor measurements2025-07-04T06:40:23ZThe efficiency of beam injection in circular accelerators can be impacted by unknown aperture limitations in the vacuum chamber. These limitations can be detected by introducing localized distortions to the closed orbit of the circulating beam observed at beam position monitors (BPMs). The localized nature of introduced closed orbit distortions enables targeted identification of loss regions. In this paper, we present a method for localizing beam losses designed primarily for circular electron accelerators using a set of sequentially placed scintillator-based beam loss monitors (BLMs). By moving these monitors along the accelerator lattice, the proposed technique achieves sub-meter spatial resolution in beam loss localization. Relative calibration of the BLMs was performed using a strontium-90 radioactive source. We report experimental results from the implementation of this method at the VEPP-4M collider.2025-07-04T06:40:23Z23 pages, 14 figures, accepted by NIM-AYu. MaltsevaI. Morozovhttp://arxiv.org/abs/2507.03155v1The MIST-1 and MIST-2 multicusp ion sources for high-current H$_2^+$ beams2025-07-03T20:25:46ZWe present two iterations of the Multicusp Ion Source Technology at MIT (MIST) sources, designed to fulfill the requirements of the HCHC-XX cyclotron design. The HCHC-XX is a novel compact cyclotron accelerating H$_2^+$. Beam is injected through a radio-frequency quadrupole buncher-accelerator (embedded in the cyclotron yoke) and utilizes so-called vortex motion during acceleration. If successful, it will deliver 10 mA of protons at 60 MeV in CW mode. This scheme requires a low-emittance, high-current initial beam with high H$_2^+$ purity. We briefly summarize the design and previous results of the MIST-1 ion source and, for the first time, the detailed design of the new and improved MIST-2, including the mechanical, electrical, and control system design. We further show experimental results of using the MIST-2 backplate on the MIST-1 body, present a study using different types of permanent magnets for confinement (including no magnets), and finally, we present first results of the MIST-2 in full operation. In this first commissioning run, we were able to increase the total extracted current from the MIST-2 to 7 mA - a factor of 2 over the MIST-1.2025-07-03T20:25:46ZSubmitted to RSIDaniel WinklehnerSamuel EngebretsonJarrett MoonJoshua VillarrealPhilip WeigelEleanor WinklerParker landonhttp://arxiv.org/abs/2502.10623v2A Compact Low-level RF Control System for Advanced Concept Compact Electron Linear Accelerator2025-07-03T17:29:17ZA compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analogue up and down conversion. Compared with the conventional heterodyne based architecture used for LLRF system of linear accelerator (LINAC), the elimination of analogue mixers can significantly reduce the size and weight of the system, especially with LINAC requires a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1 degree, on the flat top of a 2 microseconds RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. This paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.2025-02-15T01:23:09ZC. LiuL. RuckmanR. HerbstB. HongZ. LiK. KimD. AmirariR. AgustssonJ. Einstein-CurtisM. KilpatrickJ. EdelenE. NanniS. TantawiM. Kemphttp://arxiv.org/abs/2506.23668v2Plasma Accelerator For Decaying Particles2025-07-03T08:10:55ZWe introduce a plasma wakefield acceleration scheme capable of boosting initially subrelativistic particles to relativistic velocities within millimeter-scale distances. A subluminal light pulse drives a wake whose velocity is continuously matched to the beam speed through a tailored plasma density, thereby extending the dephasing length. We develop a theoretical model that is generalizable across particle mass, initial velocity, and the particular accelerating bucket being used, and we verify its accuracy with particle-in-cell simulations using laser drivers with energies in the Joule range.2025-06-30T09:45:07Z6 pages, 4 figuresChiara BadialiRafael AlmeidaBernardo MalacaRicardo FonsecaThales SilvaJorge Vieirahttp://arxiv.org/abs/2507.02269v1Numerical simulations of electron acceleration driven by heavy ion beams in plasma with alternating density gradients2025-07-03T03:22:58ZPlasma-Based Acceleration (PBA) has been demonstrated using laser, electron, and proton drivers. However, significant challenges remain in achieving high efficiency, stable acceleration, and scalable energy gain. Heavy ion beam drivers, with their high kinetic energy, offer the potential for greater energy transfer to the witness beam. Unfortunately, limited by the relatively low velocity of heavy ion, the dephasing length is really short leading to a low energy gain of the witness beam. Conventional method that increase plasma density linearly is ineffective in this context because the mismatch between the RMS beam radius and plasma wavelength will make the wakefield degrade or even disappear. In this paper, we propose a method that periodically switches the witness beam between different accelerating phase, allowing it to shift between adjacent accelerating cavities. Therefore, the plasma density does not only strictly increase, but also decrease. This will help maintain the structure of wakefield and increase the energy gain of the witness beam.2025-07-03T03:22:58ZJiangdong LiJiancheng YangGuoxing XiaJie LiuRuihu ZhuXiangwen Qiaohttp://arxiv.org/abs/2501.07568v2Construction of approximate invariants for non-integrable Hamiltonian systems2025-07-02T18:46:06ZWe present a method to construct high-order polynomial approximate invariants (AI) for non-integrable Hamiltonian dynamical systems, and apply it to modern ring-based particle accelerators. Taking advantage of a special property of one-turn transformation maps in the form of a square matrix, AIs can be constructed order-by-order iteratively. Evaluating AI with simulation data, we observe that AI's fluctuation is actually a measure of chaos. Through minimizing the fluctuations with control knobs in accelerators, the stable region of long-term motions could be enlarged.2025-01-13T18:55:11Z4 pages, 6 figures, accepted by Phys. Rev. Accel. Beams on July 2nd, 2025Phys. Rev. Accel. Beams 28, 074001, July, 2025Yongjun LiDerong XuYue Hao10.1103/m349-wmnrhttp://arxiv.org/abs/2507.01658v1Cathodes and Shape Modification of Cavity for DESY Superconducting Photoinjector2025-07-02T12:40:47ZFour DESY prototypes of the L-band superconducting RF photoinjector cavity demonstrated on-axis peak gradients above 55MV/m during multiple vertical cryogenic tests. Two of these prototypes,16G09 and 16G10, achieved these gradients with both superconducting and normal-conducting metallic cathodes, fabricated from either high-purity niobium or lower-purity copper. The DESY photoinjector, under development for over two decades as a continuous-wave electron source for FELs, differs from other SRF injectors in that its metallic cathode plug is attached directly to the cavity backplate, exposing the emitting surface to the high electric field within the cavity. This design obviates the need for a choke filter or load-lock system. The initial 1.6-cell cavity geometry was derived from the Low-Loss design developed for the CEBAF 12GeV upgrade, scaled from 1.5GHz to 1.3GHz. This shape was later replaced with the current High Gradient TESLA profile. In this report, we discuss current cathode options and present modifications to the cavity shape aimed at significantly reducing the electric field near the cathode opening2025-07-02T12:40:47Z11 pages, 14 figuresJ. SekutowiczD. BazylE. VogelD. ReschkeA. BrinkmannD. KlinkeD. KostinT. RammA. SulimovH. WeiseM. Wiencekhttp://arxiv.org/abs/2506.24107v1Determination of few femtosecond to attosecond electron bunch durations using a passive plasma lens2025-06-30T17:54:49ZDetermining the pulse duration of femtosecond electron bunches is challenging and often experimentally invasive. An effective method for measuring the duration based on the time-dependent variations in electron beam divergence induced by a passive plasma lens is described. Reconstruction of the temporal shape of the electron bunch down to $c \cdot dt=10$ nm ($\sim 30$ as) without external RF-cavities or multi-octave spanning spectrometer is shown numerically. Experimental data from a $\sim$ 3fs electron bunch demonstrates practical applicability of this method. While this approach can be used with any high current electron beam, it is particularly well matched to laser-driven and particle-driven wakefield accelerators and also accommodates electron beams with a time-dependent beam-energy (eg. 'chirp').2025-06-30T17:54:49ZAndreas SeidelCarola ZepterAlexander SävertStephan KuschelMatt Zepf